
Supplied By www.heating spares.co Tel. 0161 620 6677
C80 FF
C95 FF
gas fired fanned flue
combination boiler
the combi boiler
the combi boiler
Wall mounted,
Householders guide to central heating boilers

Supplied By www.heating spares.co Tel. 0161 620 6677
C80 FF ......................... G.C. Appliance No. 47 348 05
C95 FF ......................... G.C. Appliance No. 47 348 06
Natural Gas Models Only
Safety
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
Current Gas Safety (Installation and Use) Regulations or
rules in force. In your own interest, and that of safety, it is the
law that this boiler must be installed by a CORGI registered
installer, in accordance with the above regulations.
Tampering with sealed components or incorrect use of the
boiler will invalidate the boiler guarantee.
CAUTION.
To avoid the possibility of injury during the installation, servicing
or cleaning of this appliance care should be taken when handling
edges of sheet steel components.
Electricity Supply
This appliance must be connected to the supply via a doubleĀpole switch, fused at 3 A.
Minimum Clearances
The minimum clearances given below must be complied with in
order to maintain the safe running of the boiler and to facilitate
servicing.
Above the boiler - 160 mm (6 1/4")
At LH side of the boiler - 15 mm (
At RH side of the boiler - 35 mm (1 3/8")
Underneath the boiler casing:
for service - 150 mm (6")
Front of the boiler:
for service - 450 mm (18")
5/8")
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.
2
C80 FF and C95 FF - User's