Auto / Manual Ranging
Non-Contact Voltage (NCV) 80-600V AC
Measures AC/DC Current (352 and 354 only)
Measures AC/DC Voltage and Resistance
Measures Frequency and Capacitance (352 and
354 only)
Audible Continuity
Data Hold
Low Battery Indication
Auto Power Off
Large Numbers and Symbols
Electronic overload protection on all ranges
Warning
Safety sheet
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . . .
2 Read First
Understand and follow operating instructions
carefully. Use the meter only as specified in this
manual; otherwise, the protection provided by
the meter may be impaired.
WARNING
To avoid possible electric shock, personal injury
or death, follow these instructions:
․ Do not use if meter appears damaged, Visually
inspect the meter to ensure case is not
cracked and back case is securely in place.
․ Inspect and replace leads if insulation is
damaged,metal is exposed or probes are
cracked. Pay particular attention to the
insulation surrounding the connectors.
․ Do not use Meter if it operates abnormally as
protection maybe impaired.
․ Do not use during electrical storms or in wet
weather.
․ Do not use around explosive gas, dust or
vapor.
․ Do not apply more than the rated voltage to
the meter.
․ Do not use without the battery and the back
case properly installed.
2 Safety Information
2
․ Remove the test leads from the circuit prior to
removing battery cap.
․ Do not attempt to repair this unit as it has no
userserviceable parts.
․ Voltages exceeding 30VAC or 60VDC pose a
shock hazard so use caution.
CAUTION
To protect yourself, think “Safety First”:
․ Use appropriate personal protective equipment
such as safety glasses, face shields, insulating
gloves, insulating boots and/or insulating mats.
․ Before each use.
- Perform a continuity test by touching the test
leads together to verify the functionally of the
battery and test leads.
- Use the 3 Point Safety Method. (1) Verify
meter operation by measuring a known
voltage. (2) Apply meter to circuit under test.
(3) Return to the known live voltage again to
ensure proper operation.
․ Never ground yourself when taking electrical
measurements.
․ Connect the black common lead to ground or
neutral before applying the red test lead to
potential voltage. Disconnect the red test lead
from the voltage first.
․ Always work with a partner.
․ When using the probes, keep fingers as far
behind the probe tips as possible.
․ Never connect a source of voltage with the
function rotary switch in Ω/ :</A //Hz
position.Never set the meter in A function
to measure the voltage of a power supply
circuit in equipment that could result in
damage to the meter and the equipment
under test.
3
Symbols as marked on the meter and
Instruction card
Risk of electric shock
See instruction card
DC measurement
Equipment protected by double or
reinforced insulation
Battery
Fuse
Earth
AC measurement
Conforms to EU directives
4
Measuring AC/DC Voltage And
Frequency
5
Resistance
Disconnect
Circuit
Power off
Discharge hight-voltage
Capacitor
Testing for Continuity
6
/630V 1 F
Testing for Diode
Bad Diode
Red
Black
Red
Good Diode
Red
Black
Red
Measuring DC / AC Current
(For 352,354 only)
Disconnect
Black
Black
7
Measuring Capacitance
(For 352,354 only)
MIN MAX Re cord
8
Display Hold
Manual Ranging and Auto Ranging
Auto Power Off (Battery Saver)
10 min
9
Disable Auto Power Off
Non-Contact Voltage (NCV)
NCV
1. NCV switch will be activated on any function
or at OFF status.
2. Test leads are not used for the NCV test.
3. Press the NCV button. The display goes
black, a tone sounds and the red LED lights
up to verify the instrument is operational.
The NCV button must be held down to detect
the presence of voltage without use of the
leads.
10
Fuse Replacement (For 352 & 354 only)
Refer to the following figure to replace fuse :
Caution
․ Use only a fuse with
the amperage, interrupt,
voltage, and speed
rating specified.
․ Fuse rating : 10A, 500V
Battery Replacement
Refer to the following figure to replace the
batteries :
Caution
․ Replace the batteries as soon as the low
batteries indicator "" appears, to avoid false
reading.
․ Batteries 1.5V x 2
11
Maintenance
Do not attempt to repair this Meter. It contains
no user-serviceable parts. Repair or servicing
should only be performed by qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and
detergent. Do not use abrasives or solvents.
Average sensing rms indication.
AC conversions are ac-coupled, true rms
responding, calibrated to the sine wave input.
* The minimum LCD reading is 1400 count in Auto
Ranging Mode.
Crest Factor : C.F. = Peak / Rms
+ 1.5% addition error for C.F. from 1.4 to 3
+ 3% addition error for C.F. from 3 to 4
DC / AC Current (For 352 & 354 only)
Range DC Accuracy AC Accuracy
2.000A
10.00A **
±(1.0% + 3 dgt)
± (1.5%+5dgt) 50Hz~300Hz
± (1.5%+5dgt) 50Hz~500Hz *
Voltage
Burden
±(1.5% + 5 dgt)
50Hz ~ 500Hz
*
2V max
Overload Protection :
A input : 10A (500V) fast blow fuse
* AC Conversion Type : Conversion type and
additional specification are same as DC/AC Voltage.
* * Maximum input current restriction time :
10 minutes.
13
Resistance
Range Accuracy Voltage Burden
200.0 ~ 200.0KΩ
**
2.000MΩ ** ±(1.0% + 3 dgt)
20.00MΩ * ±(1.5% + 3 dgt)
±(0.7% + 3 dgt)
2V max
Open circuit Voltage : -1.3V approx.
* <100 dgt rolling.
* * The minimum LCD reading is 1400 count in
Auto Ranging Mode.
Diode Check and Continuity
Range Resolution Accuracy
* For 0.4V ~ 0.8V
Max.Test Current : 1.5mA
Max. Open Circuit Voltage : 2V
Overload Protection : 600V rms.
This meter is warranted to the original purchaser
against defects in material or workmanship for the
lifetime of the meter. During this warranty period,
IDEAL INDUSTRIES, INC. will, at its option,
replace or repair the defective unit, subject to
verification of the defect or malfunction.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an
IDEAL product, including but not limited to implied
warranties of merchantability and fitness for a
particular purpose, are limited to the above.
The manufacturer shall not be liable for loss of use
of the instrument or other incidental or consequential damages, expenses, or economic loss, or for
any claim or claims for such damage, expenses or
economic loss.
State laws vary, so the above limitations or
exclusions may not apply to you. This warranty
gives you specific legal rights, and you may also
have other rights which vary from state to state.