ICST MK1711-01S, MK1711-01STR Datasheet

MK1711-01
ICRO
C
LOCK
The MK1711-01 is a low cost, low jitter, high performance, high speed PLL clock synthesizer designed for high-frequency applications. Using MicroClock’s analog and digital Phase-Locked Loop (PLL) techniques, the device uses an inexpensive 20 MHz crystal to generate a high­quality output clock up to 200MHz.
MicroClock manufactures the largest variety of clock synthesizers for all applications. Consult MicroClock to eliminate crystals and oscillators from your board.
200 MHz Selectable Clock Source
Features
• Packaged in 16 pin narrow SOIC
• Uses an inexpensive 20.0 MHz crystal
• Eight selectable frequencies up to 200 MHz
• Duty cycle of 50% typical
• +3.3V operating voltage
• 25mA output drive capability at TTL levels
• Compatible with TI DSP devices
Block Diagram
S2:0
20 MHz crystal
X1
X2
3
Crystal
Oscillator
VDD
PLL/Clock
Synthesis Circuitry
VDDP
Output
Buffer
Output Enable
CLK
MDS 1711-01 B 1 Revision 120897 Printed 11/15/00
MicroClock Division of ICS•1271 Parkmoor Ave.•San Jose•CA•95126•(408)295-9800tel•(408)295-9818fax
MK1711-01
Pin Assignment
MK1711-01
X1
VDD VDD
VDDP
GND
GND
SEL3V
INVCLK
16 pin narrow (150 mil) SOIC
ICRO
16
1
15
2
14
3
13
4
12
5
11
6
10
7 8
9
C
LOCK
X2 OE
NC
CLK
NC
S0
S1 S2
200 MHz Selectable Clock Source
Output Clock Select Table (MHz)
Input S2 S1 S0 CLK1
20 0 0 0 200 20 0 0 1 182 20 0 1 0 167 20 0 1 1 154 20 1 0 0 143 20 1 0 1 133 20 1 1 0 125 20 1 1 1 118
Pin Descriptions
Number Name Type Description
1 X1 XI Crystal connection. Connect to a 20.00 MHz crystal. 2 VDD P VDD. Connect to +3.3V (Possibly 5V). 3 VDD P VDD. Connect to +3.3V (Possibly 5V). 4 VDDP P Connect to 3.3V only. 5 GND P Connect to ground. 6 GND P Connect to ground. 7 SEL3V I Select 3.3V only power supply. Connect to GND for VDD=5V. Internal pull-up. 8 INVCLK I Inverts output clock. Internal pull-up.
9 S2 I Clock Select 2. Selects output per table above. Internal pull-up. 10 S1 I Clock Select 1. Selects output per table above. Internal pull-up. 11 S0 I Clock Select 0. Selects output per table above. Internal pull-up. 12 NC - No Connect. Nothing is connected internally to this pin. 13 CLK O Clock output determined by status of S2, S1, S0. See table above. 14 NC - No Connect. Nothing is connected internally to this pin. 15 OE I Output Enable. Active high. Tri-states clock output when low. Internal pull-up. 16 X2 XO Crystal connection. Connect to a 20.00 MHz crystal.
Key: I = Input, O = output, P = power supply connection
MDS 1711-01 B 2 Revision 120897 Printed 11/15/00
MicroClock Division of ICS•1271 Parkmoor Ave.•San Jose•CA•95126•(408)295-9800tel•(408)295-9818fax