Icom BC-143, BC-144 User Manual

INSTRUCTIONS
DESKTOP CHARGERS
BC-143
(for IC-F3 series)
BC-144
(for IC-F3G, IC-F30G, IC-F11 series)
Thank you for purchasing the BC-
DESKTOP CHARGER
. The BC­143 charges a Ni-Cd, and the BC-144 charges a Ni-Cd or Ni-MH battery pack in approx. 1–2 hrs.
Please read these instructions thoroughly before operating the BC-143/BC-144.
CAUTION
RUSE INDOORS ONLY! NEVER expose the charger to rain, snow or any liquids.
NEVER let metal, wire, etc. touch any internal part of the charger.
NEVER incinerate used batteries. This may cause an explosion.
NEVER use the charger when it is covered by objects which impede heat dispersal.
• Place the charger in a secure place to avoid inadvertent use by children.
AVOID charging in conditions of extreme cold (under 10°C; +50°F) or extreme heat (over +40°C; +104°F). Batteries may not charge under extreme temperatures.
• Keep the charger away from TV sets or radios to prevent interference.
RNEVER attempt to charge alkaline or dry cell batteries. They may burst causing damage and personal injury.
Make sure battery and charger contacts are always clean, otherwise batteries may not fully charge.
In order to get the maximum life out of your Ni-Cd batteries:
1. Avoid overcharging— batteries must be removed from the charger to stop charg­ing. Batteries should not be charged for more than 15 hours after the LED indica­tor turns green.
2. Use the batteries until they become almost completely exhausted under nor­mal conditions.
If your batteries seem to have no capac­ity even after being fully charged, com­pletely discharge them, then fully charge them again. If they still do not retain a charge (or very little), new batteries must be purchased.
NOTE: The charger rapidly charges a battery pack to a specified level, not a completed level, to prevent over charg­ing. Leave the battery pack in the charg­er for a few more hours (up to 15 hours; depending on battery condition) after the LED indicator turns green, to charge the battery completely.
Recycling information (U.S.A. only)
The battery (BP-195, BP-196, BP-209 or BP-222) that you have purchased is recyclable. At the end of its life, under various state and local laws, it may be illegal to dispose of this battery into the municipal waste stream. Call 1-800­822-8837 for battery recycling options in your area or contact your dealer.
• Approx. charging period
BP-195 : 1 hour BP-196 : 1.5 hours
Battery pack MUST BE removed from the charger to stop charging. Remove battery pack after 15 hrs. of charging.
• LED indication
*When the LED indicator does not light even after a bat-
tery pack is inserted properly, the battery pack may have a problem. However, when the LED flashes orange, it is not a malfunction.
Light color
Orange
Green
Charging current
700 mA±10%
30 mA±10 mA
Description
During rapid charging Rapid charging is com-
pleted (still charging in trickle charge mode)
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan
A-5697D-1EX-
w Printed in Japan
© 2001 Icom Inc.
BP-195 or BP-196 only
BP-195 or BP-196 attached
to the transceiver.
AC adapter BC-145A/E/V/UK
AC adapter BC-145A/E/V/UK
Check orientation.
Check orientation.
The adapter supplied with the BC-143.
Charging indicator
Charging indicator
Turn power OFF
BATTERY PACK CHARGING— BC-143
, Icom Inc. are registered trademarks of Icom Incorporated (Japan) in the United States and/or
other countries.
When removing the spacer (Spacer B/C)
Push the notch carefully with your finger to remove the spacer (Spacer B/C) from the adapter (Spacer A).
R CAUTION! DO NOT push or force the notch using a
screw driver, etc., to remove it. DO NOT bend the notch when the
adapter and spacer are not joined together. This will cause weakening of the notch plastic.
Both cases may break the notch and it may not be able to be reattached.
BATTERY PACK CHARGING— BC-144
• For IC-F30G Series
The adapter (Spacer A) only is required.
• For IC-F3G Series
Attach the spacer (Spacer B/C) to the adapter (Spacer A) with the orientation as illustrated in the diagram at left.
• Attach the spacer (Spacer B/C) to the adapter with the orientation of the stamp “ ” pointing up.
• For IC-F11 Series
Attach the spacer (Spacer B/C) to the adapter (Spacer A) with the orientation as illustrated in the diagram at left.
• Attach the spacer (Spacer B/C) to the adapter with the orientation of the stamp “ ” pointing up.
Spacer A
Check orientation
and
Spacer A
Spacer B/C
Check orientation
and
Spacer A
Spacer B/C
Push the notch carefully.
Remove the spacer (Spacer B/C) from the adapter.
AD-99 SPACER COMBINATIONS
*The adapter, either the AD-94 (charging for IC-F3G series only) or AD-97 (charging for IC-F30G series
only) supplied versions are also available.
• Approx. charging period
BP-209 : 1.5 hours BP-210 : 2 hours BP-222 : 1 hour
Battery pack MUST BE removed from the charger to stop charging. Remove battery pack after 15 hrs. of charging.
• LED indication
*When the LED indicator does not light even after a bat-
tery pack is inserted properly, the battery pack may have a problem. However, when the LED flashes orange, it is not a malfunction.
Light color
Orange
Green
Charging current
800 mA±10%
30 mA±10mA
Description
During rapid charging Rapid charging is com-
pleted (still charging in trickle charge mode)
BP-209, BP-210
or BP-222 only
AC adapter BC-145A/E/V/UK
Charging indicator
BP-209, BP-210
or BP-222 attached
to the transceiver.
AC adapter BC-145A/E/V/UK
Check orientation. *
Viewable stamps may differ according to the spacer combination. See the right page for details.
Turn power OFF
Check orientation and the spacer combination. *The combination
fer according to transceiv­er type.
Details at right.
may dif-
Charging indicator
Loading...