IBM X30, MT 2672, MT2673 Service Manual


IBM Mobile Systems ThinkPad Computer Hardware Maintenance Manual
July 2002
This manual supports:
ThinkPad X30 (MT 2672/2673) ThinkPad Dock (MT 2631)
Before using this information and the product it supports, be sure to read the general information under “Notices” on page 133.
First Edition (July 2002) The following paragraph does not apply to the United
Kingdom or any country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT ANY WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE LIMITED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer or express or implied warranties in certain transactions; therefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements or changes to the products or the programs described in this publication at any time.
It is possible that this publication may contain references to, or information about, IBM products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that IBM intends to announce such IBM products, programming, or services in your country.
Requests for technical information about IBM products should be made to your IBM authorized dealer or your IBM marketing representative.
© Copyright International Business Machines Corporation 2002. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

Contents

About this manual ...........1
Introduction .............3
Important service information .........3
Strategy for replacing FRUs ........3
How to use error messages ........4
Diskette compatibility matrix .........4
Safety notices: multilingual translations ......5
Safety information............15
General safety............15
Electrical safety ...........16
Safety inspection guide .........17
Handling devices that are sensitive to electorostatic
discharge ............18
Grounding requirements .........19
Laser compliance statement.........20
General descriptions ..........23
Read this first .............23
What to do first ...........23
Related service information .........25
Service web site ...........25
Restoring the preloaded system ......25
Passwords .............28
Power management ..........30
Checkout guide ............34
Testing the computer ..........34
Detecting system information with PC-Doctor. . . 36
Power system checkout .........37
ThinkPad X30.............41
Product overview ............43
Specifications ............43
Status indicators ...........45
FRU tests .............47
Fn key combinations ..........48
Symptom-to-FRU index ..........49
Numeric error codes ..........49
Error messages ...........52
Beep symptoms ...........53
No-beep symptoms ..........53
LCD-related symptoms .........54
Intermittent problems ..........55
Undetermined problems .........55
FRU replacement notices .........56
Screw notices ............56
Retaining serial numbers.........57
Removing and replacing a FRU........59
1010 Battery pack...........60
1020 Hard-disk drive ..........61
© Copyright IBM Corp. 2002
iii
1030 DIMM ............63
1040 Backup battery ..........64
1050 Keyboard ...........65
1060 Mini PCI adapter .........69
1070 Fan assembly ..........72
1080 Communication daughter card (CDC) . . . 74
1090 Keyboard bezel..........79
1100 PC card slot...........82
1110 Hinge cover and LCD assembly .....85
1120 Sub card assembly.........89
1130 Speaker assembly .........90
1140 System board ..........92
2010 LCD front bezel..........95
2020 Inverter card ..........96
2030 LCD panel ...........98
3010 ThinkPad Dock PCI cover ......105
3020 ThinkPad Dock top cover ......107
Locations ..............112
Front view.............112
Rear view.............113
Bottom view ............114
Locations for UltraBase X3........115
Parts list ..............117
Overall..............118
LCD FRUs ............124
Keyboard .............126
Recovery CDs ...........127
Miscellaneous parts ..........129
Optional FRUs ...........130
Common parts list ..........132
Notices ..............133
Trademarks ............133
iv ThinkPad X30 (MT 2672/2673)

About this manual

This manual contains service and reference information for IBM ThinkPad X30 (MT 2672/2673), and ThinkPad Dock (MT2631) products. Use this manual along with the advanced diagnostic tests to troubleshoot problems.
The manual is divided into sections as follows: v The common sections provide general information,
guidelines, and safety information required in servicing computers.
v The product-specific section includes service, reference,
and product-specific parts information.
Important
This manual is intended for trained service
personnel who are familiar with ThinkPad products.
Use this manual along with the advanced diagnostic
tests to troubleshoot problems effectively.
Before servicing an IBM ThinkPad product, be sure
to review the safety information under Safety
notices: multilingual translationson page 5, Safety
informationon page 15, and Laser compliance
statementon page 20.
© Copyright IBM Corp. 2002 1
2 ThinkPad X30 (MT 2672/2673)

Introduction

Important service information

Important
BIOS and device driver fixes are
customer-installable. The BIOS and device drivers
are posted on the IBM support site
http://www.ibm.com/pc/support
Advise customers to contact the PC Company
HelpCenter at 800-772-2227 if they need assistance
in obtaining or installing any diskette fixes.
Customers in Canada should call IBM HelpPC at
800-565-3344 for assistance or download
information.

Strategy for replacing FRUs

Before replacing parts
Make sure that all diskette fixes are installed before
replacing any FRUs listed in this manual.
Use the following strategy to prevent unnecessary expense for replacing and servicing FRUs:
v If you are instructed to replace a FRU but the
replacement does not correct the problem, reinstall the original FRU before you continue.
v Some computers have both a processor board and a
system board. If you are instructed to replace either the processor board or the system board, and replacing one of them does not correct the problem, reinstall that board, and then replace the other one.
v If an adapter or device consists of more than one FRU,
any of the FRUs may be the cause of the error. Before replacing the adapter or device, remove the FRUs, one by one, to see if the symptoms change. Replace only the FRU that changed the symptoms.
Attention: The setup configuration on the computer you are servicing may have been customized. Running Automatic Configuration may alter the settings. Note the current configuration settings (using the View Configuration option); then, when service has been completed, verify that those settings remain in effect.
© Copyright IBM Corp. 2002
3
Important service information
Strategy for replacing a hard-disk drive
Always try to run a low-level format before replacing a hard-disk drive.
Attention: The drive startup sequence in the computer you are servicing may have been changed. Be extremely careful during write operations such as copying, saving, or formatting. If you select an incorrect drive, data or programs can be overwritten.

How to use error messages

Use the error codes displayed on the screen to diagnose failures. If more than one error code is displayed, begin the diagnosis with the first error code. Whatever causes the first error code may also cause false error codes. If no error code is displayed, see if the error symptom is listed in the Symptom-to-FRU Index for the computer you are servicing.

Diskette compatibility matrix

The compatibility of each of the drives with the diskettes for it is as follows:
Diskette drive
3.5-inch 1.0 MB Read and write
Diskette capacity
2.0 MB Read and write
4.0 MB Not compatible
Compatibility
4 ThinkPad X30 (MT 2672/2673)
Safety notices

Safety notices: multilingual translations

In this manual, safety notices appear in English with a page number reference to the appropriate multilingual, translated safety notice found in this section.
The following safety notices are provided in English, French, German, Italian, and Spanish.
Safety notice 1
Before the computer is powered-on after FRU replacement, make sure all screws, springs, and other small parts are in place and are not left loose inside the computer. Verify this by shaking the computer and listening for rattling sounds. Metallic parts or metal flakes can cause electrical shorts.
Avant de remettre lordinateur sous tension après remplacement dune unité en clientèle, vérifiez que tous les ressorts, vis et autres pièces sont bien en place et bien fixées. Pour ce faire, secouez lunité et assurez-vous quaucun bruit suspect ne se produit. Des pièces métalliques ou des copeaux de métal pourraient causer un court-circuit.
Bevor nach einem FRU-Austausch der Computer wieder angeschlossen wird, muß sichergestellt werden, daß keine Schrauben, Federn oder andere Kleinteile fehlen oder im Gehäuse vergessen wurden. Der Computer muß geschüttelt und auf Klappergeräusche geprüft werden. Metallteile oder-splitter können Kurzschlüsse erzeugen.
Prima di accendere lelaboratore dopo che é stata effettuata la sostituzione di una FRU, accertarsi che tutte le viti, le molle e tutte le altri parti di piccole dimensioni siano nella corretta posizione e non siano sparse allinterno dellelaboratore. Verificare ciò scuotendo lelaboratore e prestando attenzione ad eventuali rumori; eventuali parti o pezzetti metallici possono provocare cortocircuiti pericolosi.
Antes de encender el sistema despues de sustituir una FRU, compruebe que todos los tornillos, muelles y demás piezas pequeñas se encuentran en su sitio y no se encuentran sueltas dentro del sistema. Compruébelo agitando el sistema y escuchando los posibles ruidos que provocarían. Las piezas metálicas pueden causar cortocircuitos eléctricos.
Introduction 5
Safety notices
Safety notice 2
DANGER
Some standby batteries contain a small amount of nickel and cadmium. Do not disassemble a standby battery, recharge it, throw it into fire or water, or short-circuit it. Dispose of the battery as required by local ordinances or regulations. Use only the battery in the appropriate parts listing. Use of an incorrect battery can result in ignition or explosion of the battery.
Certaines batteries de secours contiennent du nickel et du cadmium. Ne les démontez pas, ne les rechargez pas, ne les exposez ni au feu ni à l’eau. Ne les mettez pas en court-circuit. Pour les mettre au rebut, conformez-vous à la réglementation en vigueur. Lorsque vous remplacez la pile de sauvegarde ou celle de l’horloge temps réel, veillez à n’utiliser que les modèles cités dans la liste de pièces détachées adéquate. Une batterie ou une pile inappropriée risque de prendre feu ou d’exploser.
Die Bereitschaftsbatterie, die sich unter dem Diskettenlaufwerk befindet, kann geringe Mengen Nickel und Cadmium enthalten. Sie darf nur durch die Verkaufsstelle oder den IBM Kundendienst ausgetauscht werden. Sie darf nicht zerlegt, wiederaufgeladen, kurzgeschlossen, oder Feuer oder Wasser ausgesetzt werden. Die Batterie kann schwere Verbrennungen oder Verätzungen verursachen. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Beim Ersetzen der Bereitschafts-oder Systembatterie nur Batterien des Typs verwenden, der in der Ersatzteilliste aufgeführt ist. Der Einsatz falscher Batterien kann zu Entzündung oder Explosion führen.
(continued)
6 ThinkPad X30 (MT 2672/2673)
Safety notices
(continuation of safety notice 2)
Alcune batterie di riserva contengono una piccola quantità di nichel e cadmio. Non smontarle, ricaricarle, gettarle nel fuoco o nellacqua né cortocircuitarle. Smaltirle secondo la normativa in vigore (DPR 915/82, successive disposizioni e disposizioni locali). Quando si sostituisce la batteria dellRTC (real time clock) o la batteria di supporto, utilizzare soltanto i tipi inseriti nellappropriato Catalogo parti. Limpiego di una batteria non adatta potrebbe determinare lincendio ol’esplosione della batteria stessa.
Algunas baterías de reserva contienen una pequeña cantidad de níquel y cadmio. No las desmonte, ni recargue, ni las eche al fuego o al agua ni las cortocircuite. Deséchelas tal como dispone la normativa local. Utilice sólo baterías que se encuentren en la lista de piezas. La utilización de una batería no apropiada puede provocar la ignición o explosión de la misma.
Introduction 7
Safety notices
Safety notice 3
DANGER
The battery pack contains small amounts of nickel. Do not disassemble it, throw it into fire or water, or short-circuit it. Dispose of the battery pack as required by local ordinances or regulations. Use only the battery in the appropriate parts listing when replacing the battery pack. Use of an incorrect battery can result in ignition or explosion of the battery.
La batterie contient du nickel. Ne la démontez pas, ne lexposez ni au feu ni à leau. Ne la mettez pas en court-circuit. Pour la mettre au rebut, conformez-vous à la réglementation en vigueur. Lorsque vous remplacez la batterie, veillez à nutiliser que les modèles cités dans la liste de pièces détachées adéquate. En effet, une batterie inappropriée risque de prendre feu ou dexploser.
Akkus enthalten geringe Mengen von Nickel. Sie dürfen nicht zerlegt, wiederaufgeladen, kurzgeschlossen, oder Feuer oder Wasser ausgesetzt werden. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Beim Ersetzen der Batterie nur Batterien des Typs verwenden, der in der Ersatzteilliste aufgeführt ist. Der Einsatz falscher Batterien kann zu Entzündung oder Explosion führen.
La batteria contiene piccole quantità di nichel. Non smontarla, gettarla nel fuoco o nellacqua né cortocircuitarla. Smaltirla secondo la normativa in vigore (DPR 915/82, successive disposizioni e disposizioni locali). Quando si sostituisce la batteria, utilizzare soltanto i tipi inseriti nellappropriato Catalogo parti. Limpiego di una batteria non adatta potrebbe determinare lincendio ol’esplosione della batteria stessa.
(continued)
8 ThinkPad X30 (MT 2672/2673)
Safety notices
(continuation of safety notice 3)
Las baterías contienen pequeñas cantidades de níquel. No las desmonte, ni recargue, ni las eche al fuego o al agua ni las cortocircuite. Deséchelas tal como dispone la normativa local. Utilice sólo baterías que se encuentren en la lista de piezas al sustituir la batería. La utilización de una bateríano apropiada puede provocar la ignición o explosión de la misma.
Safety notice 4
DANGER
The lithium battery can cause a fire, an explosion, or a severe burn. Do not recharge it, remove its polarized connector, disassemble it, heat it above 100°C (212°F), incinerate it, or expose its cell contents to water. Dispose of the battery as required by local ordinances or regulations. Use only the battery in the appropriate parts listing. Use of an incorrect battery can result in ignition or explosion of the battery.
La pile de sauvegarde contient du lithium. Elle présente des risques dincendie, dexplosion ou de brûlures graves. Ne la rechargez pas, ne retirez pas son connecteur polarisé et ne la démontez pas. Ne lexposez pas à une temperature supérieure à 100°C, ne la faites pas brûler et nen exposez pas le contenu à leau. Mettez la pile au rebut conformément à la réglementation en vigueur. Une pile inappropriée risque de prendre feu ou dexploser.
(continued)
Introduction 9
Safety notices
(continuation of safety notice 4)
Die Systembatterie ist eine Lithiumbatterie. Sie kann sich entzünden, explodieren oder schwere Verbrennungen hervorrufen. Batterien dieses Typs dürfen nicht aufgeladen, zerlegt, über 100 C erhitzt oder verbrannt werden. Auch darf ihr Inhalt nicht mit Wasser in Verbindung gebracht oder der zur richtigen Polung angebrachte Verbindungsstecker entfernt werden. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Beim Ersetzen der Batterie nur Batterien des Typs verwenden, der in der Ersatzteilliste aufgeführt ist. Der Einsatz falscher Batterien kann zu Entzündung oder Explosion führen.
La batteria di supporto e una batteria al litio e puo incendiarsi, esplodere o procurare gravi ustioni. Evitare di ricaricarla, smontarne il connettore polarizzato, smontarla, riscaldarla ad una temperatura superiore ai 100 gradi centigradi, incendiarla o gettarla in acqua. Smaltirla secondo la normativa in vigore (DPR 915/82, successive disposizioni e disposizioni locali). Limpiego di una batteria non adatta potrebbe determinare lincendio ol’esplosione della batteria stessa.
La batería de repuesto es una batería de litio y puede provocar incendios, explosiones o quemaduras graves. No la recargue, ni quite el conector polarizado, ni la desmonte, ni caliente por encima de los 100°C (212°F), ni la incinere ni exponga el contenido de sus celdas al agua. Deséchela tal como dispone la normativa local.
10 ThinkPad X30 (MT 2672/2673)
Safety notices
Safety notice 5
If the LCD breaks and the fluid from inside the LCD gets into your eyes or on your hands, immediately wash the affected areas with water for at least 15 minutes. Seek medical care if any symptoms from the fluid are present after washing.
Si le panneau daffichage à cristaux liquides se brise et que vous recevez dans les yeux ou sur les mains une partie du fluide, rincez-les abondamment pendant au moins quinze minutes. Consultez un médecin si des symptômes persistent après le lavage.
Die Leuchtstoffröhre im LCD-Bildschirm enthält Quecksilber. Bei der Entsorgung die örtlichen Bestimmungen für Sondermüll beachten. Der LCD-Bildschirm besteht aus Glas und kann zerbrechen, wenn er unsachgemäß behandelt wird oder der Computer auf den Boden fällt. Wenn der Bildschirm beschädigt ist und die darin befindliche Flüssigkeit in Kontakt mit Haut und Augen gerät, sollten die betroffenen Stellen mindestens 15 Minuten mit Wasser abgespült und bei Beschwerden anschließend ein Arzt aufgesucht werden.
Nel caso che caso lLCD si dovesse rompere ed il liquido in esso contenuto entrasse in contatto con gli occhi o le mani, lavare immediatamente le parti interessate con acqua corrente per almeno 15 minuti; poi consultare un medico se i sintomi dovessero permanere.
Si la LCD se rompe y el fluido de su interior entra en contacto con sus ojos o sus manos, lave inmediatamente las áreas afectadas con agua durante 15 minutos como mínimo. Obtenga atención medica si se presenta algúnsíntoma del fluido despues de lavarse.
Introduction 11
Safety notices
Safety notice 6
DANGER
To avoid shock, do not remove the plastic cover that protects the lower part of the inverter card.
Afin d’éviter tout risque de choc électrique, ne retirez pas le cache en plastique protégeant la partie inférieure de la carte dalimentation.
Aus Sicherheitsgründen die Kunststoffabdeckung, die den unteren Teil der Spannungswandlerplatine umgibt, nicht entfernen.
Per evitare scosse elettriche, non rimuovere la copertura in plastica che avvolge la parte inferiore della scheda invertitore.
Para evitar descargas, no quite la cubierta de plástico que rodea la parte baja de la tarjeta invertida.
12 ThinkPad X30 (MT 2672/2673)
Safety notices
Safety notice 7
DANGER
Though the main batteries have low voltage, a shorted or grounded battery can produce enough current to burn personnel or combustible materials.
Bien que le voltage des batteries principales soit peu élevé, le court-circuit ou la mise à la masse dune batterie peut produire suffisamment de courant pour brûler des matériaux combustibles ou causer des brûlures corporelles graves.
Obwohl Hauptbatterien eine niedrige Spannung haben, können sie doch bei Kurzschluß oder Erdung genug Strom abgeben, um brennbare Materialien zu entzünden oder Verletzungen bei Personen hervorzurufen.
Sebbene le batterie di alimentazione siano a basso voltaggio, una batteria in corto circuito o a massa può fornire corrente sufficiente da bruciare materiali combustibili o provocare ustioni ai tecnici di manutenzione.
Aunque las baterías principales tienen un voltaje bajo, una batería cortocircuitada o con contacto a tierra puede producir la corriente suficiente como para quemar material combustible o provocar quemaduras en el personal.
Introduction 13
Safety notices
Safety notice 8
DANGER
Before removing any FRU, power off the computer, unplug all power cords from electrical outlets, remove the battery pack, and then disconnect any interconnecting cables.
Avant de retirer une unité remplaçable en clientèle, mettez le système hors tension, débranchez tous les cordons dalimentation des socles de prise de courant, retirez la batterie et déconnectez tous les cordons dinterface.
Die Stromzufuhr muß abgeschaltet, alle Stromkabel aus der Steckdose gezogen, der Akku entfernt und alle Verbindungskabel abgenommen sein, bevor eine FRU entfernt wird.
Prima di rimuovere qualsiasi FRU, spegnere il sistema, scollegare dalle prese elettriche tutti i cavi di alimentazione, rimuovere la batteria e poi scollegare i cavi di interconnessione.
Antes de quitar una FRU, apague el sistema, desenchufe todos los cables de las tomas de corriente eléctrica, quite la bateríay,a continuación, desconecte cualquier cable de conexión entre dispositivos.
14 ThinkPad X30 (MT 2672/2673)

Safety information

Safety information
The following section presents the safety information that you need to be familiar with before servicing an IBM mobile computer.

General safety

Follow these rules to ensure general safety: v Observe good housekeeping in the area of the
machines during and after maintenance.
v When lifting any heavy object:
1. Ensure you can stand safely without slipping.
2. Distribute the weight of the object equally between your feet.
3. Use a slow lifting force. Never move suddenly or twist when you attempt to lift.
4. Lift by standing or by pushing up with your leg muscles; this action removes the strain from the muscles in your back. Do not attempt to lift any
object that weighs more than 16 kg (35 lb) or objects that you think are too heavy for you.
v Do not perform any action that causes hazards to the
customer, or that makes the equipment unsafe.
v Before you start the machine, ensure that other service
representatives and the customers personnel are not in a hazardous position.
v Place removed covers and other parts in a safe place,
away from all personnel, while you are servicing the machine.
v Keep your toolcase away from walk areas so that other
people will not trip over it.
v Do not wear loose clothing that can be trapped in the
moving parts of a machine. Make sure that your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it.
v Insert the ends of your necktie or scarf inside clothing or
fasten it with a nonconductive clip, approximately 8 centimeters (3 inches) from the end.
v Do not wear jewelry, chains, metal-frame eyeglasses, or
metal fasteners for your clothing. Attention: Metal objects are good electrical
conductors.
v Wear safety glasses when you are hammering, drilling,
soldering, cutting wire, attaching springs, using solvents, or working in any other conditions that might be hazardous to your eyes.
Introduction 15
Safety information
v After service, reinstall all safety shields, guards, labels,
and ground wires. Replace any safety device that is worn or defective.
v Reinstall all covers correctly before returning the
machine to the customer.

Electrical safety

Observe the following rules when working on electrical equipment.
Important
Use only approved tools and test equipment. Some hand tools have handles covered with a soft material that does not insulate you when working with live electrical currents.
Many customers have, near their equipment, rubber floor mats that contain small conductive fibers to decrease electrostatic discharges. Do not use this type of mat to protect yourself from electrical shock.
v Find the room emergency power-off (EPO) switch,
disconnecting switch, or electrical outlet. If an electrical accident occurs, you can then operate the switch or unplug the power cord quickly.
v Do not work alone under hazardous conditions or near
equipment that has hazardous voltages.
v Disconnect all power before:
Performing a mechanical inspectionWorking near power suppliesRemoving or installing main units
v Before you start to work on the machine, unplug the
power cord. If you cannot unplug it, ask the customer to power-off the wall box that supplies power to the machine and to lock the wall box in the off position.
v If you need to work on a machine that has exposed
electrical circuits, observe the following precautions: – Ensure that another person, familiar with the
power-off controls, is near you. Attention: Another person must be there to switch
off the power, if necessary.
– Use only one hand when working with powered-on
electrical equipment; keep the other hand in your pocket or behind your back.
Attention: An electrical shock can occur only when there is a complete circuit. By observing the above rule, you may prevent a current from passing through your body.
16 ThinkPad X30 (MT 2672/2673)
Safety information
– When using testers, set the controls correctly and
use the approved probe leads and accessories for that tester.
– Stand on suitable rubber mats (obtained locally, if
necessary) to insulate you from grounds such as metal floor strips and machine frames.
Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages.
v Regularly inspect and maintain your electrical hand tools
for safe operational condition.
v Do not use worn or broken tools and testers. v Never assume that power has been disconnected from
a circuit. First, check that it has been powered off.
v Always look carefully for possible hazards in your work
area. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds.
v Do not touch live electrical circuits with the reflective
surface of a plastic dental mirror. The surface is conductive; such touching can cause personal injury and machine damage.
v Do not service the following parts with the power on
when they are removed from their normal operating places in a machine:
Power supply unitsPumpsBlowers and fansMotor generators
and similar units. (This practice ensures correct grounding of the units.)
v If an electrical accident occurs:
Use caution; do not become a victim yourself.Switch off power.Send another person to get medical aid.

Safety inspection guide

The purpose of this inspection guide is to assist you in identifying potentially unsafe conditions. As each machine was designed and built, required safety items were installed to protect users and service personnel from injury. This guide addresses only those items. You should use good judgment to identify potential safety hazards due to attachment of non-IBM features or options not covered by this inspection guide.
Introduction 17
Safety information
If any unsafe conditions are present, you must determine how serious the apparent hazard could be and whether you can continue without first correcting the problem.
Consider these conditions and the safety hazards they present:
v Electrical hazards, especially primary power (primary
voltage on the frame can cause serious or fatal electrical shock)
v Explosive hazards, such as a damaged CRT face or a
bulging capacitor
v Mechanical hazards, such as loose or missing hardware To determine whether there are any potentially unsafe
conditions, use the following checklist at the beginning of every service task. Begin the checks with the power off, and the power cord disconnected.
Checklist:
1. Check exterior covers for damage (loose, broken, or sharp edges).
2. Power-off the computer. Disconnect the power cord.
3. Check the power cord for: a. A third-wire ground connector in good condition.
Use a meter to measure third-wire ground continuity for 0.1 ohm or less between the external ground pin and frame ground.
b. The power cord should be the type specified in the
parts list.
c. Insulation must not be frayed or worn.
4. Remove the cover.
5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations.
6. Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or other liquids, or signs of fire or smoke damage.
7. Check for worn, frayed, or pinched cables.
8. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with.

Handling devices that are sensitive to electorostatic discharge

Any computer part containing transistors or integrated circuits (ICs) should be considered sensitive to electrostatic discharge (ESD.) ESD damage can occur when there is a difference in charge between objects. Protect against ESD
18 ThinkPad X30 (MT 2672/2673)
Safety information
damage by equalizing the charge so that the machine, the part, the work mat, and the person handling the part are all at the same charge.
Notes
1. Use product-specific ESD procedures when they exceed the requirements noted here.
2. Make sure that the ESD protective devices you use have been certified (ISO 9000) as fully effective.
When handling ESD-sensitive parts: v Keep the parts in protective packages until they are
inserted into the product.
v Avoid contact with other people. v Wear a grounded wrist strap against your skin to
eliminate static on your body.
v Prevent the part from touching your clothing. Most
clothing is insulative and retains a charge even when you are wearing a wrist strap.
v Use the black side of a grounded work mat to provide a
static-free work surface. The mat is especially useful when handling ESD-sensitive devices.
v Select a grounding system, such as those listed below,
to provide protection that meets the specific service requirement.
The use of a grounding system is desirable but not required to protect against ESD damage.
– Attach the ESD ground clip to any frame ground,
ground braid, or green-wire ground.
– Use an ESD common ground or reference point
when working on a double-insulated or battery-operated system. You can use coax or connector-outside shells on these systems.
– Use the round ground-prong of the AC plug on
AC-operated computers.

Grounding requirements

Electrical grounding of the computer is required for operator safety and correct system function. Proper grounding of the electrical outlet can be verified by a certified electrician.
Introduction 19

Laser compliance statement

Laser compliance statement
Some IBM Personal Computer models are equipped from the factory with an optical storage device such as a CD-ROM drive or a DVD-ROM drive. They are also sold separately as options. The drive is certified in the U.S. to conform to the requirements of the Department of Health and Human Services 21 Code of Federal Regulations (DHHS 21 CFR) Subchapter J for Class 1 laser products. Elsewhere, the drive is certified to conform to the requirements of the International Electrotechnical Commission (IEC) 825 and CENELEC EN 60 825 for Class 1 laser products.
20 ThinkPad X30 (MT 2672/2673)
Laser compliance statement
When a CD-ROM drive, DVD drive or the other laser product is installed, note the following:
CAUTION:
Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.
O uso de controles, ajustes ou desempenho de procedimentos diferentes daqueles aqui especificados pode resultar em perigosa exposição à radiação.
Pour éviter tout risque dexposition au rayon laser, respectez les consignes de réglage et dutilisation des commandes, ainsi que les procédures décrites.
Werden Steuer- und Einstellelemente anders als hier festgesetzt verwendet, kann gefährliche Laserstrahlung auftreten.
Lutilizzo di controlli, regolazioni o lesecuzione di procedure diverse da quelle specificate possono provocare lesposizione a.
El uso de controles o ajustes o la ejecuciónde procedimientos distintos de los aquí especificados puede provocar la exposición a radiaciones peligrosas.
Opening the CD-ROM drive, DVD-ROM drive or the other optical storage device could result in exposure to hazardous laser radiation. There are no serviceable parts inside those drives. Do not open.
Introduction 21
Laser compliance statement
Some CD-ROM drives, DVD-ROM drives, or other optical storage devices contain an embedded Class 3A or Class 3B laser diode. Note the following:
DANGER
Emits visible and invisible laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
Radiação por raio laser ao abrir. Não olhe fixo no feixe de luz, não olhe diretamente por meio de instrumentos óticos e evite exposição direta com o feixe de luz.
Rayonnement laser si carter ouvert. Évitez de fixer le faisceau, de le regarder directement avec des instruments optiques, ou de vous exposer au rayon.
Laserstrahlung bei geöffnetem Gerät. Nicht direkt oder über optische Instrumente in den Laserstrahl sehen und den Strahlungsbereich meiden.
Kinyitáskor lézersugár!Nenézzen bele se szabad szemmel, se optikai eszközökkel. Kerülje a sugárnyalábbal valóérintkezést !.
Aprendo lunità vengono emesse radiazioni laser. Non fissare il fascio, non guardarlo direttamente con strumenti ottici e evitare lesposizione diretta al fascio.
Radiaciónláser al abrir. No mire fijamente ni examine con instrumental óptico el haz de luz. Evite la exposición directa al haz.
22 ThinkPad X30 (MT 2672/2673)

General descriptions

This chapter includes descriptions for any ThinkPad model that has the PC-Doctor DOS diagnostics program. Some descriptions might not apply to your particular computer.

Read this first

Before you go to the checkout guide, be sure to read this section.
Important notes
v Only certified trained personnel should
service the computer.
v Read the entire FRU removal and replacement
page before replacing any FRU.
v Use new nylon-coated screws when you
replace FRUs.
v Be extremely careful during such write
operations as copying, saving, or formatting.
Drives in the computer that you are servicing sequence might have been altered. If you select an incorrect drive, data or programs might be overwritten.
v Replace FRUs only for the correct model.
When you replace a FRU, make sure the model of the machine and the FRU part number are correct by referring to the FRU parts list.
v A FRU should not be replaced because of a
single, unreproducible failure. Single failures
can occur for a variety of reasons that have nothing to do with a hardware defect, such as cosmic radiation, electrostatic discharge, or software errors. Consider replacing a FRU only when a problem recurs. If you suspect that a FRU is defective, clear the error log and run the test again. If the error does not recur, do not replace the FRU.
v Be careful not to replace a nondefective FRU.

What to do first

When you do return a FRU, you must include the following information in the parts exchange form or parts return form that you attach to it: __ 1. Name and phone number of servicer __ 2. Date of service __ 3. Date on which the machine failed
© Copyright IBM Corp. 2002
23
Read this first
__ 4. Date of purchase __ 5. Failure symptoms, error codes appearing on the
display, and beep symptoms
__ 6. Procedure index and page number in which the
failing FRU was detected __ 7. Failing FRU name and part number __ 8. Machine type, model number, and serial number __ 9. Customers name and address
Note for warranty:
During the warranty period, the customer may be responsible for repair costs if the computer damage was caused by misuse, accident, modification, unsuitable physical or operating environment, or improper maintenance by the customer. The following list provides some common items that are not covered under warranty and some symptoms that might indicate that the system was subjected to stress beyond normal use.
Before checking problems with the computer, determine whether the damage is covered under the warranty by referring to the following:
The following are not covered under warranty:
v LCD panel cracked from the application of excessive
force or from being dropped
v Scratched (cosmetic) parts v Distortion, deformation, or discoloration of the cosmetic
parts
v Cracked or broken plastic parts, broken latches, broken
pins, or broken connectors caused by excessive force
v Damage caused by liquid spilled into the system v Damage caused by the improper insertion of a PC Card
or the installation of an incompatible card
v Damage caused by foreign material in the diskette drive v Diskette drive damage caused by pressure on the
diskette drive cover or by the insertion of a diskette with multiple labels
v Damaged or bent diskette eject button v Fuses blown by attachment of a nonsupported device v Forgotten computer password (making the computer
unusable)
v Sticky keys caused by spilling a liquid onto the keyboard
The following symptoms might indicate damage caused by nonwarranted activities:
v Missing parts might be a symptom of unauthorized
service or modification.
v If the spindle of a hard-disk drive becomes noisy, it may
have been subjected to excessive force, or dropped.
24 ThinkPad X30 (MT 2672/2673)

Related service information

Related service information
This section provides information about the following:
v Service web site v Restoring the preloaded system v Passwordson page 28 v Power managementon page 30

Service web site

When the latest maintenance diskette and the system program service diskette become available, a notice will be posted on http://www.ibm.com/pc/partner/infotips

Restoring the preloaded system

If the data on a hard-disk drive is damaged or accidentally erased, you can restore the software that was shipped with the computer. This software includes the pre-installed operating system, applications, and device drivers.
To restore the pre-installed software, you can use either the Product Recovery program or a recovery CD.
Ordering the recovery CD
When the hard-disk drive is replaced because of a failure, no Product Recovery program is on the new hard disk. In this case, you must use the Product Recovery CD for the computer. Order the recovery CD and the hard-disk drive at the same time so that you can recover the new hard-disk drive with the pre-installed software when they arrive. For information on which CD to order, see Recovery CDson page 127
The Product Recovery program is in the service partition, a section of the hard-disk drive that is not displayed by Windows Explorer.
Attention: All of the files on the primary hard-disk partition (usually drive C) will be lost in the recovery process. Be sure to back up copies of the files you have saved on your drive C before you begin.
Creating a Recovery Repair diskette
If the operating system cannot boot normally, or if you cannot get access to the Product Recovery program, you can use the Recovery Repair diskette to boot the computer. Make a Recovery Repair diskette and save it for future use. To make a Recovery Repair diskette, do the following:
1. Shut down and restart the computer.
General descriptions 25
Related service information
2. At the prompt, press F11. (The option to press F11
appears for only a few seconds. You must press F11 quickly.) The Product Recovery program main menu opens.
Note: If you are prompted to select the operating
system, select one you want to recover. Then the Product Recovery program main menu opens.
3. Select System Utilities from the main menu. Press
Enter.
4. Select Create a Recovery Repair diskette. Press
Enter.
5. Follow the on-screen instructions.
6. When the process is completed, label the diskette
Recovery Repair disketteand save it for future use.
Product Recovery program
Note: The recovery process might take up to 2 hours.
To use the Product Recovery program to restore the pre-installed software, do the following:
1. Save all files and shut down the desktop.
2. Turn off the computer.
3. Turn on the computer. If you are using Windows XP,
three messages (F1, F11, and F12) appear on the screen for a few seconds. One of them is Press F11 to invoke the IBM Product Recovery program”. While the message is displayed, quickly press F11.
If you are using Windows 2000 or another operating system, the startup screen is displayed first, and then the message To start the Product Recovery program, press F11” at the top of the screen. Here again it appears very briefly; watch for it, and press F11 before it disappears.
Note: If this message is not displayed, you can use a
Recovery Repair diskette to get access to the Product Recovery program. (For using a Recovery Repair diskette, see To use the Recovery Repair diskette:on page 28.)
4. From the list displayed on the screen, select the
operating system you want to recover.
5. Select the recovery options you want, and follow the
instructions on the screen.
6. When the Product Recovery program finishes running,
the computer will restart with the pre-installed operating system, drivers, and software.
26 ThinkPad X30 (MT 2672/2673)
Loading...
+ 108 hidden pages