IBM 2498B24, SAN24B-4, System Storage SAN24B-4 Express Installation, Service And User Manual

IBM System Storage SAN24B-4 Express

Installation, Service, and User Guide
Serviceinformation:2498-B24,24E
Read Before Using
This product contains software that is licensed under written license agreements. Your use of such software is subject to the license agreements under which they are provided.
GA32-0580-02
IBM System Storage SAN24B-4 Express

Installation, Service, and User Guide
Serviceinformation:2498-B24,24E
GA32-0580-02
Note:
Before using this information and the product it supports, read the information in “Notices” on page 39.
Copyright © 2008-2010 Brocade Communications Systems, Inc. All Rights Reserved.
The following paragraph does not apply to any country (or region) where such provisions are inconsistent with local law.
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states (or regions) do not allow disclaimer of express or implied warranties in certain transactions; therefore, this statement may not apply to you.
© Copyright IBM Corporation 2008, 2010.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Read this first
Summary of changes
|
| | | | |
|
|
| |
|
|
| |
|
|
|
|
|
Third edition
Second edition
This is the third edition of the IBM System Storage SAN24B-4 Express Installation, Service, and User Guide. The content changes since the last edition of this
publication are noted by a vertical line placed in the left margin beside each change. Minor edits are not identified by this mark. A summary of the changes for each edition are listed below.
The following changes were made in the third edition: v Addition of information about the Server Application Optimization (SAO)
optional feature
v A change to the Fabric Operating System (FOS) required version v Update of environmental notices v Reorganization of general information, including the addition of the Read This
First section
v Update of the Notices section v Update of how to submit reader comments
The following changes were made in the second edition: v Corrections to LED status tables
Getting help
| | | |
For the latest version of your product documentation, visit the web at www.ibm.com/e-business/linkweb/publications/servlet/pbi.wss?. Search by form number or title.
®
For more information about IBM www.ibm.com/servers/storage/san/
For support information for this product and other IBM products, see the following Web site: www.ibm.com/systems/support/supportsite.wss/. Select System Storage. On the next page, select your product family, and then select the specific product.
You can also contact IBM within the United States at 1-800-IBMSERV (1-800-426-7378). For support outside the United States, you can find the service number at: www.ibm.com/planetwide/.
Visit www.ibm.com/contact for the contact information for your country or region.
For detailed information about the Fibre Channel standards, see the Fibre Channel Industry Association (FCIA) Web site at: www.fibrechannel.org/
For information about storage industry standards, see the Storage Networking Industry Association (SNIA) Web site at: www.snia.org/
SAN products, see the following Web site:
© Copyright IBM Corp. 2008, 2010 iii
Taiwan Contact Information
IBM Taiwan Product Service Contact Info: IBM Taiwan Corporation 3F, No 7, Song Ren Rd., Taipei Taiwan Tel: 0800-016-888
Accessibility features for the SAN26B-4 Express
Accessibility features help users who have a disability, such as restricted mobility or limited vision, to use information technology products successfully.
Accessibility features
The following list includes the major accessibility features in this product: v Light emitting diodes (LEDs) that flash at different rates, to represent the same
information as the colors of the LEDs
v Industry-standard devices for ports and connectors v Management of the product through management applications is available
through Web and Graphical User Interface (GUI) options
Keyboard navigation
This product does not have an attached or integrated keyboard. Any keyboard navigation is provided through the management software and GUI.
Vendor software
This product includes certain vendor software that is not covered under the IBM license agreement. IBM makes no representation about the accessibility features of these products. Contact the vendor for the accessibility information about its products.
Related accessibility information
You can view the publications for this product in Adobe®Portable Document Format (PDF) using the Adobe Acrobat Reader. The PDFs are provided on a product documentation CD-ROM that is packaged with the product. The CD-ROM also includes an accessible HTML version of this document.
IBM and accessibility
See the IBM Human Ability and Accessibility Center web site at http://www.ibm.com/able/ for more information about the commitment that IBM has to accessibility.
How to send your comments
Your feedback is important in helping us provide the most accurate and high-quality information. If you have comments or suggestions for improving this document, send us your comments by e-mail to starpubs@us.ibm.com. Be sure to include the following:
iv SAN24B-4 Express Installation, Service, and User Guide
v Exact publication title v Form number (for example, GC27-2270-00) v Page numbers to which you are referring
You can also mail your comments to:
International Business Machines Corporation Information Development Department GZW 9000 South Rita Road Tucson, Arizona 85744-0001 U.S.A.
When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you.
Read this first v
vi SAN24B-4 Express Installation, Service, and User Guide
Contents
Read this first ............iii
Summary of changes ...........iii
||
Third edition .............iii
||
Second edition ............iii
||
Getting help ..............iii
Taiwan Contact Information ........iv
Accessibility features for the SAN26B-4 Express . . iv
Accessibility features ..........iv
Keyboard navigation ..........iv
Vendor software ............iv
Related accessibility information ......iv
IBM and accessibility ..........iv
How to send your comments ........iv
Figures ...............ix
Tables ...............xi
About this document ........xiii
Product documents ...........xiii
Brocade documents ...........xiii
IBM and Brocade product matrix ......xiv
Safety and environmental notices .......xiv
Safety notices and labels .........xiv
Rack safety .............xx
Product recycling and disposal ......xxii
||
Chapter 1. Introducing the SAN24B-4
Express switch............1
Features and functions of the switch ......1
Supported connectivity ...........2
Port side of the switch ...........2
Nonport side of the switch .........3
Supported fabric configurations ........3
Additional port activation ..........3
ISL Trunking groups............3
Supported optional features .........4
Chapter 2. Installing and configuring the
switch ...............7
Items included with the switch ........7
Installation and safety considerations ......8
Electrical considerations .........8
Environment considerations ........8
Cabinet considerations ..........8
Installing a stand-alone switch ........9
Installing the switch into an EIA cabinet .....9
Time required ............10
Items required ............10
Installation instructions .........10
Recommendations for cable management ....15
Configuring the switch ..........16
Using the EZSwitch setup (optional) .....16
Providing power to the switch .......16
Creating a serial connection ........17
Setting the switch IP address .......17
Setting the date and time .........18
Chapter 3. Operating the switch ....21
Powering the switch on and off........21
Interpreting LED activity ..........21
LED locations ............22
LED patterns .............23
POST and boot specifications ........25
POST...............25
Boot ................25
Interpreting POST results ..........26
Switch FRU units ............26
Maintaining the switch ..........26
Installing SFPs ............26
Diagnostic tests ............30
Managing the switch ...........30
Appendix. Product specifications . . . 33
Weight and physical dimensions .......33
Environmental requirements.........33
Facility requirements ...........34
System specifications ...........35
Memory specifications ...........35
Data transmission ranges ..........36
Fibre Channel port specifications .......36
Serial port specifications ..........36
Power supply specifications .........36
Supported SFPs and HBAs .........37
Notices ..............39
Trademarks ..............41
Electronic emission notices .........42
Federal Communications Commission (FCC)
Class A Statement ...........42
Industry Canada Class A Emission Compliance
Statement ..............42
Avis de conformité à la réglementation
d'Industrie Canada ...........42
European Union EMC Directive Conformance
Statement ..............42
Germany Electromagnetic Compatibility Directive 43
People's Republic of China Class A Electronic
Emission Statement ...........44
Japan VCCI Council Class A Statement ....44
Japan Electronics and Information Technology
Industries Association (JEITA) Statement . . . 45
Korea Communications Commission (KCC)
Statement ..............45
Russia Electromagnetic Interference (EMI) Class
A Statement .............45
Australia and New Zealand Class A Statement 45
Index ...............47
© Copyright IBM Corp. 2008, 2010 vii
viii SAN24B-4 Express Installation, Service, and User Guide
Figures
1. Port side of the switch .........2
2. Trunking groups ...........4
3. Rack assembly ...........11
4. Separating the inner and outer rails ....12
5. Mounting the moving portion of the slide and
mounting brackets to the switch .....13
6. Mounting the fixed portion of the rail and the
locking brackets to the rack .......14
7. Inserting slides into the rack rails .....15
8. Detailed view, location of LEDs on the switch 22
9. SFP installation and bail closing......27
10. Removing an SFP ..........28
© Copyright IBM Corp. 2008, 2010 ix
x SAN24B-4 Express Installation, Service, and User Guide
Tables
1. Brocade and IBM product and model number
matrix ..............xiv
2. Sample caution notices ........xviii
3. Parts supplied with the rack-mount kit 11
4. Power status LED patterns, status, and
recommended actions .........23
5. System status LED patterns, status, and
recommended actions .........23
6. Port LED patterns during normal operation 24
7. Ethernet LED patterns .........25
8. Management options for the switch ....30
9. Physical dimensions and weight of the switch 33
10. Environmental requirements .......33
11. Facility requirements .........34
12. General specifications .........35
13. Memory specifications .........35
14. Data transmission ranges ........36
15. Switch power supply specifications ....36
© Copyright IBM Corp. 2008, 2010 xi
xii SAN24B-4 Express Installation, Service, and User Guide
About this document
This document is intended for use by systems administrators and technicians experienced with networking, Fibre Channel, and storage area network (SAN) technologies. It describes how to install, service, and use the IBM System Storage SAN24B-4 Express (machine type 2498, models 24B and E24). Throughout this document, the product is referred to as the SAN24B-4, or simply the switch to apply to both models.
This document has been created to include information specific to SAN24B-4
| | |
Product documents
switches running on Fabric OS version v6.1.1. This document does not support all Fabric OS versions. It is specific to Fabric OS v6.1.1 or later. To obtain information about a Fabric OS version other than v6.1.1, refer to the documentation specific to your Fabric OS version.
The sections that follow provide information about:
v “Product documents” v “Brocade documents” v “Safety and environmental notices” on page xiv
| | | | | | | |
| |
|
| |
|
|
The following documents contain information related to this product. The documentation may be printed material or may be on the documentation CD that is shipped with the product. Newer versions of product documentation may be available through the IBM Publications Center Web site http://www.ibm.com/e­business/linkweb/publications/servlet/pbi.wss. Newer versions may also be available through the IBM Systems Support Web site www.ibm.com/systems/ support/supportsite.wss/. Select your product family, then the specific product, and then select Documentation.
v IBM System Storage SAN24B-4 Express Installation, Service, and User's Guide,
v IBM System Storage SAN24B-4 Express Quick Start Guide GA32-0585
v IBM System Storage SAN24B-4 Express Access Gateway Quick Start Guide
v IBM Systems Safety Notices, G229–9054 v IBM Warranty
Brocade documents
IBM b-type switches use software licensed from Brocade Communications Systems, Inc. You can find information related to the software that supports the director in the following documents on the CD-ROM supplied with this product:
Brocade Fabric OS
v Fabric OS Administrator's Guide
v Fabric OS Command Reference Manual
v Fabric OS MIB Reference Manual
v Fabric OS Message Reference Manual
GA32-0580 (this document)
GA32-0588
© Copyright IBM Corp. 2008, 2010 xiii
v Fabric OS Troubleshooting and Diagnostics Guide
v Access Gateway Administrator's Guide
v EZSwitchSetup Administrator's Guide
v SAN Glossary
Brocade Fabric OS optional features
v Fabric Watch Administrator's Guide
v Web Tools Administrator's Guide
|
|
Brocade HBA publication
v Brocade Adapters Administrator’s Guide
IBM and Brocade product matrix
When you use any of the Brocade documents, you will notice that the model numbers reflect the original Brocade products. Table 1 provides a product matrix for you to use to correlate the Brocade products and models to the IBM product names and machine types and model numbers. Products withdrawn from marketing are not listed.
Table 1. Brocade and IBM product and model number matrix
IBM machine type and
Brocade product name IBM product name
Brocade DCX-4S SAN384B 2499 Model 192
Brocade DCX SAN768B 2499 Model 384
Brocade 48000 SAN256B Director 2109 Model M48
Brocade 8000 IBM Converged Switch B32 3758 Models B32 and L32
Brocade 7800 SAN06B-R 2498 Model R06
Brocade 7500E SAN04B–R 2005 Model R04
Brocade 5300 SAN80B-4 2498 Model B80
Brocade 5100 SAN40B-4 2498 Models B40 and 40E
Brocade 300 SAN24B-4 2498 Models B24 and 24E
model number
Safety and environmental notices
This section contains information about:
v “Safety notices and labels” v “Rack safety” on page xx v “Product recycling and disposal” on page xxii
Safety notices and labels
When using this product, observe the danger, caution, and attention notices contained in this guide. The notices are accompanied by symbols that represent the severity of the safety condition. The danger and caution notices are listed in numerical order based on their IDs, which are displayed in parentheses, for example (D004), at the end of each notice. Use this ID to locate the translation of these danger and caution notices in the IBM Systems Safety Notices (G229–9054) publication, which is on the CD-ROM that accompanies this product.
xiv SAN24B-4 Express Installation, Service, and User Guide
The following notices and statements are used in IBM documents. They are listed below in order of increasing severity of potential hazards. Follow the links for more detailed descriptions and examples of the danger, caution, and attention notices in the sections that follow.
v Note: These notices provide important tips, guidance, or advice. v “Attention notices” on page xix: These notices indicate potential damage to
programs, devices, or data.
v “Caution notices” on page xvii: These statements indicate situations that can be
potentially hazardous to you.
v “Danger notices”: These statements indicate situations that can be potentially
lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these situations.
v In addition to these notices, “Safety labels” on page xix may be attached to the
product to warn of potential hazards.
Danger notices
A danger notice calls attention to a situation that is potentially lethal or extremely hazardous to people. A lightning bolt symbol accompanies a danger notice to represent a dangerous electrical condition. Read and comply with the following danger notices before installing or servicing this device.
DANGER
To prevent a possible shock from touching two surfaces with different protective ground (earth), use one hand, when possible, to connect or disconnect signal cables. (D001)
DANGER
Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device or the power rating label for electrical specifications. (D002)
DANGER
If the receptacle has a metal shell, do not touch the shell until you have completed the voltage and grounding checks. Improper wiring or grounding could place dangerous voltage on the metal shell. If any of the conditions are not as described, STOP. Ensure the improper voltage or impedance conditions are corrected before proceeding. (D003)
About this document xv
DANGER
An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (D004)
The following general electrical danger notice provides instructions on how to avoid shock hazards when servicing equipment. Unless instructed otherwise, follow the procedures in the following danger notice.
xvi SAN24B-4 Express Installation, Service, and User Guide
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard:
v Connect power to this unit only with the IBM provided power
cord. Do not use the IBM provided power cord for any other product.
v Do not open or service any power supply assembly.
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
v The product might be equipped with multiple power cords. To
remove all hazardous voltages, disconnect all power cords.
v Connect all power cords to a properly wired and grounded
electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate.
v Connect any equipment that will be attached to this product to
properly wired outlets.
v When possible, use one hand only to connect or disconnect
signal cables.
v Never turn on any equipment when there is evidence of fire,
water, or structural damage.
v Disconnect the attached power cords, telecommunications
systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described below when
installing, moving, or opening covers on this product or attached devices.
To disconnect:
1. Turn off everything (unless instructed otherwise).
2. Remove the power cords from the outlets.
3. Remove the signal cables from the connectors.
4. Remove all cables from the devices.
To connect:
1. Turn off everything (unless instructed otherwise).
2. Attach all cables to the devices.
3. Attach the signal cables to the connectors.
4. Attach the power cords to the outlets.
5. Turn on the devices.
(D005)
Caution notices
A caution notice calls attention to a situation that is potentially hazardous to people because of some existing condition. A caution notice can be accompanied by different symbols, as in the examples below:
About this document xvii
Table 2. Sample caution notices
If the symbol is... It means....
A hazardous electrical condition with less severity than electrical danger.
A generally hazardous condition not represented by other safety symbols.
A specification of product weight that requires safe lifting practices. The weight range of the product is listed below the graphic, and the graphic and the wording of
18-32 kg (39.7-70.5 lbs)
svc00167
the caution varies, depending on the weight of the device.
18-32 kg (39.7-70.5 lbs)
A potential hazard of pinching the hand or other body parts between parts.
P/N 18P5850-B
SJ000752
A hazardous condition due to moving parts nearby.
A hazardous condition due to the use of a laser in the product. Laser symbols are always accompanied by the classification of the laser as defined by the U. S. Department of Health and Human Services (for example, Class I, Class II, and so forth).
Read and comply with the following caution notices before installing or servicing this device.
CAUTION: Energy hazard present. Shorting may result in system outage and possible physical injury. Remove all metallic jewelry before servicing. (C001)
CAUTION: This part or unit is heavy but has a weight smaller than 18 kg (39.7 lb). Use care when lifting, removing, or installing this part or unit. (C008)
CAUTION: This product is equipped with a 3-wire (two conductors and ground) power cable and plug. Use this power cable with a properly grounded electrical outlet to avoid electrical shock. (C018)
CAUTION: Servicing of this product or unit is to be performed by trained service personnel only. (C032)
xviii SAN24B-4 Express Installation, Service, and User Guide
Safety labels
As an added precaution, safety labels are often installed directly on products or product components to warn of potential hazards. These can be either danger or caution notices, depending upon the level of the hazard.
The actual product safety labels may differ from these sample safety labels:
DANGER
Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001)
DANGER
Rack-mounted devices are not to be used as a shelf or work space. (L002)
DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003)
DANGER
Hazardous voltage present. Voltages present constitute a shock hazard, which can cause severe injury or death. (L004)
Attention notices
An attention notice indicates the possibility of damage to a program, device, or system, or to data. An exclamation point symbol may accompany an attention notice, but is not required. A sample attention notice follows:
Attention: Do not bend a fibre cable to a radius less than 5 cm (2 in.); you can damage the cable. Tie wraps are not recommended for optical cables because they can be easily overtightened, causing damage to the cable.
About this document xix
Rack safety
Rack installation
DANGER
Observe the following precautions when working on or around your IT rack system:
v Heavy equipment—personal injury or equipment damage might result if
mishandled.
v Always lower the leveling pads on the rack cabinet.
v Always install stabilizer brackets on the rack cabinet.
v To avoid hazardous conditions due to uneven mechanical loading, always install the
heaviest devices in the bottom of the rack cabinet. Always install servers and optional devices starting from the bottom of the rack cabinet.
v Rack-mounted devices are not to be used as shelves or work spaces. Do not place
objects on top of rack-mounted devices.
v Each rack cabinet might have more than one power cord. Be sure to disconnect all
power cords in the rack cabinet when directed to disconnect power during servicing.
v Connect all devices installed in a rack cabinet to power devices installed in the
same rack cabinet. Do not plug a power cord from a device installed in one rack cabinet into a power device installed in a different rack cabinet.
v An electrical outlet that is not correctly wired could place hazardous voltage on the
metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock.
(R001 part 1 of 2) CAUTION:
v Do not install a unit in a rack where the internal rack ambient temperatures will
exceed the manufacturer ’s recommended ambient temperature for all your rack-mounted devices.
v Do not install a unit in a rack where the air flow is compromised. Ensure that air flow
is not blocked or reduced on any side, front, or back of a unit used for air flow through the unit.
v Consideration should be given to the connection of the equipment to the supply circuit
so that overloading of the circuits does not compromise the supply wiring or overcurrent protection. To provide the correct power connection to a rack, refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit.
v (For sliding drawers) Do not pull out or install any drawer or feature if the rack stabilizer
brackets are not attached to the rack. Do not pull out more than one drawer at a time. The rack might become unstable if you pull out more than one drawer at a time.
v (For fixed drawers) This drawer is a fixed drawer and must not be moved for servicing
unless specified by the manufacturer. Attempting to move the drawer partially or completely out of the rack might cause the rack to become unstable or cause the drawer to fall out of the rack.
(R001 part 2 of 2)
xx SAN24B-4 Express Installation, Service, and User Guide
Rack relocation (19" rack)
CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building:
v Reduce the weight of the rack cabinet by removing equipment starting at the
top of the rack cabinet. When possible, restore the rack cabinet to the configuration of the rack cabinet as you received it. If this configuration is not known, you must do the following:
– Remove all devices in the 32U position and above.
– Ensure that the heaviest devices are installed in the bottom of the rack
cabinet.
– Ensure that there are no empty U-levels between devices installed in the
rack cabinet below the 32U level.
– If the rack cabinet you are relocating is part of a suite of rack cabinets,
detach the rack cabinet from the suite.
– Inspect the route that you plan to take when moving the rack to eliminate
potential hazards.
– Verify that the route that you choose can support the weight of the loaded
rack cabinet. Refer to the documentation that came with your rack cabinet for the weight of a loaded rack cabinet.
– Verify that all door openings are at least 760 x 2030 mm (30 x 80 in.).
– Ensure that all devices, shelves, drawers, doors, and cables are secure.
– Ensure that the four leveling pads are raised to their highest position.
– Ensure that there is no stabilizer bracket installed on the rack cabinet
during movement.
– Do not use a ramp inclined at more than 10 degrees.
– Once the rack cabinet is in the new location, do the following:
- Lower the four leveling pads.
- Install stabilizer brackets on the rack cabinet.
- If you removed any devices from the rack cabinet, repopulate the rack cabinet from the lowest position to the highest position.
– If a long distance relocation is required, restore the rack cabinet to the
configuration of the rack cabinet as you received it. Pack the rack cabinet in the original packaging material, or equivalent. Also, lower the leveling pads to raise the casters off of the pallet and bolt the rack cabinet to the pallet.
(R002)
About this document xxi
|
| | | |
Product recycling and disposal
Refer to the IBM Systems Environmental Notices and User Guide (Z125-5823) for translated environmental statements and information regarding product recycling and disposal. This document may be provided either in printed version or on the product documentation CD.
xxii SAN24B-4 Express Installation, Service, and User Guide
Chapter 1. Introducing the SAN24B-4 Express switch
The IBM System Storage SAN24B-4 Express is a cost-effective and highly-scalable 1, 2, 4, or 8 Gbit/sec switch, designed for small to mid-sized businesses. It runs on the Fabric Operating System (Fabric OS) and is compatible with other IBM switches, which enables seamless connectivity into heterogeneous SAN environments. This switch is a dual purpose device that you can use either as a full-functioned switch or as an N_Port ID Virtualization (NPIV) access gateway. When functioning as an access gateway, the it provides a single platform for all SAN connectivity. Because the switch is scalable, you can use it as a foundation switch for a small storage area network (SAN) and continue to use it as a building block as the SAN grows.
This chapter provides the following information:
v “Features and functions of the switch” v “Supported connectivity” on page 2 v “Port side of the switch” on page 2 v “Nonport side of the switch” on page 3 v “Additional port activation” on page 3 v “ISL Trunking groups” on page 3 v “Supported optional features” on page 4
Features and functions of the switch
The switch provides the following features and functions: v 1U chassis–The chassis can be installed as a standalone unit or mounted in a
standard Electronic Industries Association (EIA) 48.26 cm (19 in.) cabinet.
v One built-in fixed power unit (not field-replaceable) v Three built-in fans (none are field-replaceable). The switch is cooled by a
redundant fan configuration, which allows continued operation with a single fan failure.
v On-demand scaling of 8 to 24 8 Gbit/sec ports v ASIC technology supporting 1, 2, 4 and 8Gbit/sec auto-sensing Fibre Channel
ports.
v Ability to operate as either a full-functioned switch or an NPIV access gateway. v RJ45 Ethernet management port that in conjunction with EZSwitchSetup,
supports switch IP address discovery and configuration.
v Uses EZSwitchSetup wizard for setup and basic configuration. v Single motherboard design with a 667 MHz PowerPC
Instruction Set Computer (RISC) CPU with integrated peripherals.
v Offers forward and backward compatibility with IBM System Storage SAN
switch models, 1, 2, 4 and 8 Gbps auto-sensing capability, as well as Advanced Fabric Services and management tools.
v Enables interoperability between IBM System Storage b-type and m-type SAN
switches and directors.
v Inter-Switch-Link Trunking (licensable) enables up to eight ports (at 1G, 2G, 4G,
or 8G speeds) between a pair of switches to be combined to form a single,
®
440EPx Reduced
© Copyright IBM Corp. 2008, 2010 1
logical ISL switch with a speed of up to 64 Gbits/sec (128 Gbits/sec full duplex) for optimal bandwidth utilization and load balancing.
v Advanced Zoning. v Intelligent management and monitoring with Web Tools, Fabric Watch, and
Performance Monitor.
v Adaptive Networking Services uses network intelligence to anticipate congestion
and to dynamically make adjustments in the fabric so that application traffic continues to flow
v Dynamic Path Selection (DPS) optimizes fabric-wide performance and load
balancing by automatically routing data to the most efficient available path in the fabric.
v Light emitting diodes (LEDs) to indicate system power, system status, Ethernet
speed and link status, and port status.
Supported connectivity
Specific details on supported operating systems, servers, and devices, storage products attachability, SAN connectivity products, and configuration options can be found in the interoperability matrices at the following web site: www.ibm.com/servers/storage/support/san.
Port side of the switch
Figure 1 shows the port side of the switch. All LEDs are on the port side of the switch: the nonport side is used to allow the free flow of air. The switch enclosure has forced-air cooling, with the fans pushing the air from the nonport side of the chassis through the enclosure, exhausting to the port side. For a complete description of the locations and interpretations of these LEDs, see “Interpreting LED activity” on page 21.
1
2 3
1
Figure 1. Port side of the switch
Item number Description
1 System status (top) and power (bottom)
2 System RS232 console port (RJ-45)
3 Ethernet Port with two Ethernet status LEDs
4 USB port
5 Fibre Channel status LEDs
6 Fibre Channel Ports (24)
7 AC power receptacle
4
5 6
LEDs
7
B24_0001
2 SAN24B-4 Express Installation, Service, and User Guide
Nonport side of the switch
The nonport side of the switch is used solely for air flow. There are no features on this side.
Supported fabric configurations
The switch is supported as an edge device in fabrics of up to 239 switches.
Additional port activation
The switch can be purchased with 8, 16, or 24 licensed ports. As your needs increase, you can activate unlicensed ports by purchasing and installing the additional 8 port activation feature. After it has been installed, the license appears under the licenseShow command as Ports on Demand license.
The additional ports are ready to be unlocked in the switch firmware. The license might be part of the licensed paper pack supplied with switch software, or you can purchase the license separately from IBM, who will provide you with a key to unlock it.
By default, ports 0 through 7 are enabled on the switch. To enable ports 8 through 16, install a Ports on Demand license key. To enable ports 16 through 24, install another Ports on Demand license.
After you have installed the license keys, you must enable the ports. You can do so without disrupting switch operation by using the portEnable command on each port individually. Alternatively, you can disable and reenable the switch to activate all ports simultaneously.
To install the additional port activation license, you can either use the supplied license key or generate a license key. Typically the switch is shipped with a paper pack that specifies the transaction key to use with the Software License Keys link.
Use this transaction key at the following Web site: http://www.ibm.com/servers/ storage/support/san.
1. On that page, from the Product list, select your product.
2. Select Download from the Support & downloads section.
3. From the page that is generated, select License request in the Tool/utility
section.
4. Follow the instructions on that page to generate the key. You can also use this site to generate other license keys for your switch.
ISL Trunking groups
The switch supports Interswitch Link (ISL) Trunking as a licensed feature. When this feature is enabled, create Trunked groups of up to 8 contiguous ports. This means that you can create up to three trunked groups that contain 8 ports each. The Fibre Channel ports on the switch are numbered from left to right and color-coded within groups of eight to indicate which ports you can combine into trunked groups.
Chapter 1. Introducing the SAN24B-4 Express switch 3
B
A
B
Figure 2. Trunking groups
v A–Trunk Group 1: ports 0 through 7 v B–Trunk Group 2: ports 8 through 15 v C–Trunk Group 3: ports 16 through 23
Note: ISL Trunking is optional software that allows you to create trunking groups
of ISLs between adjacent switches. For more information about trunking, refer to the Fabric OS Administrator’s Guide.
Supported optional features
The switch supports the following optional software, which you can activate by purchasing the corresponding license key:
v Extended Fabric–allows implementation of long distance dynamic (LD) and long
distance static (LS) distance levels. This feature extends SAN fabrics beyond the Fibre Channel standard 10 km by optimizing the internal switch buffers to maintain performance on ISLs at distances up to 500 kilometers.
v Fabric Watch–monitors mission-critical switch operations. This feature is
designed to enable real-time proactive awareness of the health, performance, and security of each switch. It automatically alerts network managers to problems and helps avoid costly failures by providing:
– Real-time tracking of numerous fabric and switch elements – Automatic event notifications when switch and fabric elements exceed
thresholds
– Security, availability, and congestion monitoring thresholds and alerts
v Adaptive Networking– provides a set of capability allowing high priority
connections to obtain the bandwidth necessary for optimum performance, even in congested environments.
v Advanced Performance Monitor–provides Performance Monitoring capability to
help identify end-to-end bandwidth usage by host/target pairs and is designed to provide information for capacity planning.
v Trunking Activation–designed to enable Fibre Channel packets to be efficiently
distributed across multiple Inter-Switch connections (links) between two SAN b-type fabric switches, while preserving in-order delivery. ISL Trunking is supported between any of the supported 2, 4, or 8 Gbps b-type models. Both SAN b-type fabric switches must have ISL Trunking activated.
| |
v Server Application Optimization (SAO)–designed to bring Quality of Service
(QoS) enhancements for server consolidation and virtualization
C
B24_0002
In addition, customers can order a set of optional features bundled into one orderable feature, the B24 Enterprise Package. This bundled feature consists of one of each of Fabric Watch, Trunking Activation, Advanced Performance Monitor, Adaptive Networking, and two 8-Port Activations.
4 SAN24B-4 Express Installation, Service, and User Guide
For more information on the use of these features, refer to the Fabric OS Administrator’s Guide.
Chapter 1. Introducing the SAN24B-4 Express switch 5
6 SAN24B-4 Express Installation, Service, and User Guide
Chapter 2. Installing and configuring the switch
You can install the switch in either of two ways:
v As a stand-alone unit on a flat surface v In an Electronic Industries Association (EIA) cabinet using a slide-rail rack
mount kit, which is provided with the switch. When you mount the switch into a slide-rail rack, you can mount the chassis to slide from either the port side or the non-port side.
The SAN24B-4 can be configured and operated as either a SAN fabric switch or as an Access Gateway. The configuration instructions in this publication are for the SAN24B-4 to operate as a switch. The installation instructions in this document apply to both Switch and Access Gateway modes. To configure and operate the SAN24B-4 in Access Gateway mode, refer to the IBM System Storage SAN24B-4 Access Gateway Quick Start Guide and the Access Gateway Administrator's Guide.
Attention: When you enable Access Gateway mode, you disable the ability for the SAN24B-4 to operate as a switch. Access Gateway mode and switch mode are mutually exclusive. If you want to use the SAN24B-4 as a switch at a later time, you will need to disable Access Gateway mode and enable switch mode. Changing between Access Gateway and Switch modes is a data disruptive operation. It is strongly recommended that you disable the switch from the command line interface before enabling or disabling Access Gateway mode.
This chapter provides the following information:
v “Items included with the switch” v “Installation and safety considerations” on page 8 v “Installing a stand-alone switch” on page 9 v “Installing the switch into an EIA cabinet” on page 9 v “Recommendations for cable management” on page 15 v “Configuring the switch” on page 16
Items included with the switch
The following items are included with the standard shipment of the switch. When you open the packaging, verify that these items are included in the package and that no damage has occurred during shipping:
v One SAN24B-4 switch v An accessory kit that contains the following items:
– Serial cable with an RJ-45 connector – One grounded 1.8 m (6 ft.) country-specific power cord – Four rubber feet, required for setting up the switch as a stand-alone unit – SFP transceivers (quantity depending upon features ordered) – IBM System Storage SAN24B-4 Installation, Service, and User Guide (this
document) – IBM System Storage SAN24B-4 Quick Start GuideIBM System Storage SAN24B-4 Access Gateway Quick Start Guide – IBM documentation CD
© Copyright IBM Corp. 2008, 2010 7
– EZSwitchSetup CD – One LC wrap plug
Installation and safety considerations
Use this section to prepare your site for a safe and successful installation.
Attention: Although the switch has been designed for customer installation and replacement procedures, you must first ensure that the rack into which the switch is to be installed is also customer accessible. If it is not, then only trained personnel can install and service these switches in such a rack.
Attention: Read the “Safety and environmental notices” on page xiv before attempting any installation or maintenance procedures.
The switch can be installed either as a free-standing unit, or installed in an EIA cabinet, using an optional slide-rail rack mount kit. When mounting into a slide-rail rack, you can mount the chassis to slide from either the port side or the nonport side.
Electrical considerations
To install and operate the switch successfully, ensure the following: v The primary outlet is correctly wired, protected by a circuit breaker, and
grounded in accordance with local electrical codes.
v The supply circuit, line fusing, and wire size are adequate, as specified by the
electrical rating on the switch nameplate.
v The power supply standards provided in “Power supply specifications” on page
36 are met.
Environment considerations
For successful installation and operation of the switch, ensure that the following environmental requirements are met:
v At a minimum, adequate cooling requires that you install the switch with the
nonport side, which contains the air intake vents, facing the cool-air aisle.
v All equipment in the rack should force air in the same direction to avoid
intaking exhaust air.
v A minimum of 680 l/min (24 cubic ft/min) of air flow is available to the air
intake vents on the nonport side of the switch.
v The ambient air temperature does not exceed 40° C (104° F) while the switch is
operating.
Cabinet considerations
Attention: See “Rack safety” on page xx for danger and caution notices related to product installations in racks or cabinets.
For successful installation and operation of the switch in a cabinet, ensure that the following cabinet requirements are met:
v The cabinet must be a standard EIA cabinet.
8 SAN24B-4 Express Installation, Service, and User Guide
v Plan a cabinet space that is 1 rack unit 4.45 cm (1.75 in.) high, 48.3 cm (19 in)
wide.
v Ground all equipment in the cabinet through a reliable branch circuit connection
and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip.
v Ensure that airflow and temperature requirements are met on an ongoing basis,
particularly if the switch is installed in a closed or multicabinet assembly.
v Verify that the additional weight of the switch does not exceed the cabinet’s
weight limits or unbalance the cabinet in any way.
v Secure the cabinet to ensure stability in case of unexpected movement, such as
an earthquake.
Installing a stand-alone switch
To install the switch as a stand-alone unit, use the following procedure:
1. Unpack the switch and verify the items listed in “Items included with the switch” on page 7
2. Apply the adhesive rubber feet. Applying the rubber feet onto the switch helps prevent the switch from sliding off the supporting surface.
a. Clean the indentations at each corner of the bottom of the switch to ensure
that they are free of dust or other debris that might lessen the adhesion of the feet.
b. With the adhesive side against the chassis, place one rubber foot in each
indentation and press into place.
3. Place the switch on a flat, sturdy surface.
4. Provide power to the switch as described in “Powering the switch on and off”
on page 21.
Attention: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see “Configuring the switch” on page 16.
Installing the switch into an EIA cabinet
Attention: Although the switch has been designed for customer installation and replacement procedures, you must first ensure that the rack into which the switch is to be installed is also customer accessible. If it is not, then only trained personnel can install and service these switches in such a rack.
Attention: Read the “Safety and environmental notices” on page xiv before attempting any installation or maintenance procedures.
Attention: Refer to “Rack safety” on page xx for danger and caution notices related to rack and cabinet installations.
You can install the rack mount kit in either of two ways: v To allow the port side of the switch to slide out of the exhaust-air side of the
cabinet. In this installation, the port side of the switch is flush with the edge of the cabinet.
Chapter 2. Installing and configuring the switch 9
v To allow the non-port side of the switch to slide out the cool-air side of the
cabinet. In this installation, the port side of the switch is set 7.62 cm (3 in.) back from the edge of the cabinet, allowing a more gradual bend in the fiber optic cables.
Time required
Approximately 30 minutes
Items required
You need the following items to install the switch in a slide-rail rack:
v Straight slot screwdriver v Rack space: 1 EIA unit of rack space, 48.3 cm (19 in.) wide, and 60.96 cm (24 in.)
deep
v One power cord that is provided with the switch v One power outlet v Rack mount kit
Attention: Use the exact screws specified in the procedure for use with the switch chassis. Using screws longer than 3/16 in. can damage the switch. The different types of screws are listed in Table 3 on page 11.
Note: Make sure that you tighten all screws used in this procedure.
Installation instructions
To install the switch in a slide-rail rack that meets EIA standards, use the following procedure.
Note: These procedures use parts that are included in the rack-mount kit. These
parts are listed in Table 3 on page 11. The installation procedure cross-references the items in this table. Be sure to use the referenced parts when you perform each step.
Before you start the rack-mount installation process, locate the rack-mount slides and the mounting bracket that are provided in the shipping container.
Figure 3 on page 11 shows the rack assembly. The number keys, such as 1, refer to the items listed in Table 3 on page 11.
10 SAN24B-4 Express Installation, Service, and User Guide
4
4X
Inner Slide
3
Front of Switch
7
2X
Figure 3. Rack assembly
EIA Rack Rail
2
Outer Slide
6
2X
5X
9
8X
2X
See
1
Detail A
7
4X
5
7
4X
6
4X
10
8X
11
8X
12
8X
Detail A
SJ000153
1. Unpack the rack-mount kit and verify that all ordered items and parts are present and undamaged. See Table 3 for a list of parts and the quantities supplied.
Table 3. Parts supplied with the rack-mount kit
Item Description Quantity
1 Rack mount slide (inner and outer slide) 2
2 Right rack mount bracket (optional bracket
for front of switch)
3 Left rack mount bracket (optional bracket for
front of switch)
4 Rack mounting bracket (3-hole) 4
5 Nut clip, M5 11
6 Screw, 8-32 x 3/16 in., zinc 11
7 Screw, M5 x 12 11
8 Bracket to slide rack kit (contains items 9 -
12)
9 Screw, 8-32 x 3/8 in., zinc 5
10 Washer, flat, No. 8 5
11 Washer, lock, No. 8 5
12 Nut, hex, 8-32 5
1
1
1
Chapter 2. Installing and configuring the switch 11
2. Separate the inner and outer slides. a. Open one of the slides until the lock engages. b. Press the lock release lever (1 in Figure 4) and remove the inner rail from
the outer rail.
Figure 4. Separating the inner and outer rails
c. Repeat step 2a and step 2b for the other rail.
1
SJ000046
®
Note: For racks with flush-mount doors, such as the 9306 Netfinity
racks, do not install the front brackets. Instead, use the rack-mount slides by attaching the switch to the set of mounting holes, which are offset 3 inches into the rack.
3. Install the inner (smaller) slide on the switch chassis, as Figure 3 on page 11 shows.
Attention: If you use screws longer than 3/16 in., you can damage the switch. a. Position the flat side of the inner rail along one side of the switch. Align the
holes in the rail with the threaded holes in the side of the switch chassis. The chamfered end of the inner rail should face toward the rear of the switch (away from the ports) as shown in Figure 5 on page 13.
b. Attach the inner rail by using three of the 8-32 x 3/16 in. zinc screws (6 in
Table 3 on page 11).
12 SAN24B-4 Express Installation, Service, and User Guide
1
6
3
Front
Figure 5. Mounting the moving portion of the slide and mounting brackets to the switch
c. Repeat step 3a on page 12 and step 3b on page 12 for the second inner rail
on the other side of the switch chassis.
4. Optional step: If desired, install the right rack mount bracket 2 (see Figure 3 on page 11) and the left rack mount bracket 3 on the switch chassis. Use these brackets to secure the switch to the rack as shown in Figure 5.
Attention: Do not use screws longer than 3/16 in.; they can damage the switch.
a. Position the left rack mount bracket at the left front corner of the switch
chassis. Align the two holes in the bracket with the two threaded holes in the switch chassis.
b. Attach the bracket by using two of the 8-32 x 3/16 in. zinc screws (see 6
in Figure 3 on page 11)
c. Repeat step 4a and step 4b for the right rack mount bracket on the right
front corner of the switch chassis.
5. Attach all four of the 3-hole rack mounting brackets 4 in Figure 6 on page 14. a. Position a 3-hole rack mounting bracket 4 at the end of one of the outer
slides.
b. Attach the bracket by using the 8-32 x 3/8 in. zinc screws 9. Ensure that
the screw heads are inside the slides.
c. Place one each of the following items on the outer end of the screw in the
order listed:
1) Washer, flat No. 8 10
2) Washer, lock No. 8 11
3) Nut, hex, 8-32 12
d. Repeat steps 5a through 5c for the three remaining rail ends.
SJ000047
Chapter 2. Installing and configuring the switch 13
4
12
11
10
1
5
9
4
3
Figure 6. Mounting the fixed portion of the rail and the locking brackets to the rack
SJ000048
6. Install the outer (larger) slides in the rack, as shown in Figure 6.
a. At the desired height, install the five M5 nut clips 5. Put three M5 nut
clips in the front of the rack and two in the back. The middle clip in the front of the rack is for the locking ears.
Note: Some rack mount kits might use 10-32 nut clips in place of the M5
nut clips for the locking ears.
b. Attach the slides by using four M5 x 12 screws 7 (see Figure 3 on page
11).
c. Repeat step 6a and step 6b for the other rail.
7. Install the switch in the rack. a. Position the switch in front of the rack. Insert the switch into the rack by
sliding the inner slides that are mounted on the switch into the outer slides that are mounted on the rack. See Figure 7 on page 15.
14 SAN24B-4 Express Installation, Service, and User Guide
SJ000049
Figure 7. Inserting slides into the rack rails
b. Check the alignment of the slides by sliding the switch in and out of the
rack. Any difficulty moving the switch indicates lateral stress or misalignment. If this situation occurs, adjust the slide positions until the movement is smooth.
8. Optional step: If the right and left rack mount brackets are installed on the front corners of the switch, attach both brackets to the cabinet rack by using M5 x 12 screws 7. See step 4 on page 13 and Figure 3 on page 11. The screws should pass through the front of each bracket and the slide rail.
Note: Some rack mount kits might use 10-32 nut clips in place of the M5 nut
clips for the locking ears.
9. Continue with initial setup of the switch by following the procedures in “Configuring the switch” on page 16.
DANGER
An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (D004)
Note: Do not connect the switch to the network until you perform one of the
Recommendations for cable management
Attention: The minimum bend radius for a 50 micron cable is 51 mm (2 in.) under full tensile load and 30.5 mm (1.2 in.) with no tensile load.
following steps:
v Set the internet protocol (IP) address. v Verify that the default IP address does not conflict with the existing IP
addresses in the same network.
Chapter 2. Installing and configuring the switch 15
Cables can be organized and managed in a variety of ways: for example, using cable channels on the sides of the cabinet or patch panels to minimize cable management. Following is a list of recommendations:
v Plan for rack space required for cable management before installing the switch. v Leave at least 1 meter (3.28 ft) of slack for each port cable. This provides room
to remove and replace the switch, allows for inadvertent movement of the rack, and helps prevent the cables from being bent to less than the minimum bend radius.
v If you are using Brocade ISL Trunking, consider grouping cables by trunking
groups. The cables used in trunking groups must meet specific requirements, as described in the Fabric OS Administrator's Guide.
v For easier maintenance, label the fiber optic cables and record the devices to
which they are connected.
v Keep LEDs visible by routing port cables and other cables away from the LEDs. v Use hook-and-loop fasteners to secure and organize fibre optic cables. Do not
use tie wraps on fiber optic cables, because wraps are easily overtightened and can damage the optic fibers.
Configuring the switch
You must configure the switch to ensure correct operation within a network and fabric. For instructions about how to configure the switch to operate in a fabric that contains switches from other vendors, refer to the Fabric OS Administrator's Guide.
For more information about the commands used in this procedure, refer to the Fabric OS Command Reference Manual.
v “Using the EZSwitch setup (optional)” v “Providing power to the switch” v “Creating a serial connection” on page 17 v “Setting the switch IP address” on page 17 v “Setting the date and time” on page 18
Using the EZSwitch setup (optional)
Once you have set up the switch in a rack or as a stand-alone switch, it is time to give it power and a basic configuration. If you are going to use the switch in a single-switch setup, you can use EZSwitchSetup to complete the basic configuration. See the EZSwitchSetup CD included with the accessory kit for more information. You can also use the SAN24B-4 Quick Start Guide. If you do not want to use EZSwitch Setup, use the instructions in following sections.
Providing power to the switch
To provide power to the switch:
1. Connect the power cord to the power receptacle on the port side of the switch, and then to the power source. Ensure that the cord has a minimum service loop of 15 cm (6 in.) available and is routed to avoid stress. The switch does not have a on/off power switch. This means that power is supplied to the switch as soon as you connect it to an AC power source. The status LEDs display amber until POST is complete, and then change to green. The switch usually requires from 1 to 3 minutes to boot and complete POST.
16 SAN24B-4 Express Installation, Service, and User Guide
2. After POST is complete, verify that the switch power and status LEDs on the left of the port side of the switch are green.
Creating a serial connection
You will perform all basic configuration tasks in this guide using a serial connection. To create a serial connection to the switch, complete the following steps:
1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation. If the serial port on the workstation is RJ-45 instead of RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation.
2. Disable any serial communication programs running on the workstation.
3. Open a terminal emulator application (such as HyperTerminal on a PC, or
TERM, TIP, or Kermit in a UNIX as follows:
®
v In a Windows
Bits per second 9600
Databits 8
Parity None
Stop bits 1
environment:
®
environment), and configure the application
Flow control None
v In a UNIX environment, type the following string at the prompt:
tip /dev/ttyb -9600
If ttyb is already in use, use ttya instead and enter the following string at the prompt:
tip /dev/ttya -9600
Setting the switch IP address
You can configure the switch with a static IP address, or you can use a DHCP (Dynamic Host Configuration Protocol) server to set the IP address of the switch. DHCP is enabled by default. The switch supports both IPv4 and IPv6.
Using DHCP
When using DHCP, the switch obtains its IP address, subnet mask, and default gateway address from the DHCP server. The DHCP client can only connect to the a DHCP server that is on the same subnet as the switch. If your DHCP server is not on the same subnet as the switch, use a static IP address.
Setting a static IP address
1. Log into the switch using the default password, which is password.
2. Use the ipaddrset command to set the Ethernet IP address.
If you are going to use an IPv4 IP address, enter the IP address in dotted decimal notation as prompted.
Ethernet IP Address: [192.168.74.102]
If you are going to use an IPv6 address, enter the network information in semicolon-separated notation as prompted.
Chapter 2. Installing and configuring the switch 17
switch:admin> ipaddrset -ipv6 --add 1080::8:800:200C:417A/64 IP address is being changed...Done.
3. Complete the rest of the network information as prompted.
Ethernet Subnetmask: [255.255.255.0]
Ethernet IP Address: [192.168.74.102] Ethernet Subnetmask: [255.255.255.0]
4. Enter off to Disable DHCP when prompted.
DHCP [OFF]: off
Setting the date and time
The switch maintains the current date and time inside a battery-backed real-time clock (RTC) circuit. Date and time are used for logging events. Switch operation does not depend on the date and time; a switch with an incorrect date and time value still functions properly. However, because the date and time are used for logging, error detection, and troubleshooting, you should set them correctly.
Setting the date
1. If you are not already logged into the switch; do so now using the default password, which is password.
2. Enter the date command, using the following syntax:
date "mmddHHMMyy"
The values represent the following:
v mm is the month; valid values are 01 through 12 v dd is the date; valid values are 01 through 31 v HH is the hour; valid values are 00 through 23 v MM is minutes; valid values are 00 through 59 v yy is the year; valid values are 00 through 99 (values greater than 69 are
interpreted as 1970 through 1999, and values less than 70 are interpreted as 2000-2069)
switch:admin> date Fri Sep 29 17:01:48 UTC 2007 switch:admin> date "0927123007" Thu Sep 27 12:30:00 UTC 2007 switch:admin>
Setting time zones
You can set the time zone for a switch by name. You can specify the setting using country and city or time zone parameters. If the time zone is not set with the new options, the switch retains the offset time zone settings. The tsTimeZone command also includes an option to revert to the prior time zone format. For more information about the tstimezone [--old] option, see the Fabric OS Command Reference Manual.
You can set the time zone for a switch using the tsTimeZone command. The tsTimeZone command allows you to perform the following tasks:
v Display all of the time zones supported in the firmware v Set the time zone based on a country and city combination or based on a time
zone ID such as PST
18 SAN24B-4 Express Installation, Service, and User Guide
The time zone setting has the following characteristics: v You can view the time zone settings. However, only those with administrative
permissions can set the time zones.
v The tsTimeZone setting automatically adjusts for Daylight Savings Time. v Changing the time zone on a switch updates the local time zone setup and is
reflected in local time calculations.
v By default, all switches are in the GMT time zone (0,0). If all switches in a fabric
are in one time zone, it is possible for you to keep the time zone setup at the default setting.
v System services that have already started will reflect the time zone changes only
after the next reboot.
v Time zone settings persist across failover for high availability.
The following procedure describes how to set the time zone for a switch. You must perform the procedure on all switches for which the time zone must be set. However, you only need to set the time zone once on each switch, because the value is written to nonvolatile memory.
1. If you are not already logged into the switch; do so now using the default password, which is password.
2. Enter the tsTimeZone command as follows:
switch:admin> tstimezone [--interactive]/ [, timezone_fmt]
Use timezone_fmt to set the time zone by Country/City or by time zone ID, such as PST. The following example shows how to display the current time zone setup and how to change the time zone to US/Central.
switch:admin> tstimezone Time Zone : US/Pacific switch:admin> tstimezone US/Central switch:admin> tstimezone Time Zone : US/Central
The following procedure describes how to set the current time zone using interactive mode to Pacific Standard Time.
1. Type the tsTimeZone command as follows:
switch:admin> tstimezone --interactive
2. You are prompted to select a general location.
Please identify a location so that time zone rules can be set correctly.
3. Enter the appropriate number or Ctrl-D to quit.
4. At the prompt, select a country location.
5. At the prompt, enter the appropriate number to specify the time zone region or
Ctrl-D to quit.
Synchronizing local time using NTP
You can synchronize the local time of the principal or primary fabric configuration server (FCS) switch to a maximum of eight external network time protocol (NTP) servers. To keep the time in your SAN current, it is recommended that the principal or primary FCS switch has its time synchronized with at least one external NTP server. The other switches in the fabric will automatically take their time from the principal or primary FCS switch.
Chapter 2. Installing and configuring the switch 19
All switches in the fabric maintain the current clock server value in non-volatile memory. By default, this value is the local clock server <LOCL> of the principal or primary FCS switch. Changes to the clock server value on the principal or primary FCS switch are propagated to all switches in the fabric.
For more information on using an NTP server, and IPv6 considerations, see the Fabric OS Administrator’s Guide.
1. If you are not already logged into the switch; do so now using the default password, which is password.
2. Enter the tsClockServer command:
switch:admin> tsclockserver "<ntp1;ntp2>"
where ntp1 is the IP address or DNS name of the first NTP server, which the switch must be able to access. The second ntp2 is the second NTP server and is optional. The operand “<ntp1;ntp2>” is optional; by default, this value is LOCL, which uses the local clock of the principal or primary switch as the clock server.
The tsClockServer command accepts multiple server addresses in either IPv4, IPv6, or DNS name formats. When multiple NTP server addresses are passed, tsclockserver sets the first obtainable address as the active NTP server. The rest will be stored as backup servers that can take over if the active NTP server fails. The principal or primary FCS switch synchronizes its time with the NTP server every 64 seconds.
switch:admin> tsclockserver LOCL switch:admin> tsclockserver "132.163.135.131" switch:admin> tsclockserver
132.163.135.131
switch:admin>
The following example shows how to set up more than one NTP server using a DNS name:
switch:admin> tsclockserver "10.32.170.1;10.32.170.2;ntp.localdomain.net" Updating Clock Server configuration...done. Updated with the NTP servers Changes to the clock server value on the principal or primary FCS switch
are propagated to all switches in the fabric.
20 SAN24B-4 Express Installation, Service, and User Guide
Chapter 3. Operating the switch
This chapter provides the following information:
v “Powering the switch on and off” v “Interpreting LED activity” v “LED patterns” on page 23 v “POST and boot specifications” on page 25 v “Interpreting POST results” on page 26 v “Switch FRU units” on page 26 v “Maintaining the switch” on page 26 v “Managing the switch” on page 30
v
Powering the switch on and off
See Chapter 2, “Installing and configuring the switch,” on page 7 for initial setup instructions before powering the switch on for the first time. Once the switch has been properly configured, follow these instructions to power the switch on and off.
The SAN24B-4 does not have an AC power switch. To power on the SAN24B-4, connect the power cable to the AC receptacle on the switch and to a power source. The switch runs POST by default each time it is powered on, reset, or rebooted, and requires a minimum of three minutes to run. To end the flow of power to the switch, remove the power cord from the power source.
Interpreting LED activity
System activity and status can be determined through the activity of the LEDs on the switch. All LEDs are located on the port side of the switch. There are three possible LED states: no light, a steady light, and a flashing light. The steady lights and flashing lights can be green or amber. The LEDs flash either of these colors during boot, POST, or other diagnostic tests. This is normal and does not indicate a problem unless the LEDs do not indicate a healthy state after all boot processes and diagnostic tests are complete.
The switch has the following LEDs:
v System power LED–One LED (green) to indicate system power v System status LED–One LED (green/amber) to indicate system status v Ethernet status LEDs–Two LEDs to indicate speed and link status v Port status LEDs–24 LEDs (green/amber) to indicate status for each port
© Copyright IBM Corp. 2008, 2010 21
LED locations
All the switch LEDs are located on the port side. Figure 8 shows the location of individual LEDs
B24_0003
F
A
E
B
CD
Figure 8. Detailed view, location of LEDs on the switch
Item LED names and descriptions
A System power LED (green)
B System status LED (green/amber)
C Ethernet link status LED
D Ethernet link speed LED
E Port status LED for port 3
F Port status LED for port 7
22 SAN24B-4 Express Installation, Service, and User Guide
LED patterns
Table 4 through Table 7 on page 25 summarize the switch LED locations, color, and meaning, as well as any recommended user response.
Power status LED patterns
The power status LED patterns are shown in Table 4
Table 4. Power status LED patterns, status, and recommended actions
LED name LED color Status of hardware
Power Status LED No light Primary power cord
System status LED patterns
The system status LED patterns are shown in Table 5
Table 5. System status LED patterns, status, and recommended actions
LED name LED color Status of hardware
System Status LED No light Switch is off, boot is
Recommended action
Verify that switch is is disconnected or is not actively powered, or power supply has failed.
Steady green Switch is on and
power supply is functioning properly.
not complete, or boot failed.
Steady green Switch is operational. No action is required.
Slow-flashing green (on 1 second, off 1 second)
Amber Switch is faulty, or
One or both of the following are true: Oneormore environmental ranges are exceeded. Error log contains one or more port diagnostic error messages.
initializing.
on and has
completed booting.
Verify cord
connections are
secure.
No action is required.
Recommended
action
Verify that switch is
on and has
completed booting.
Check environmental
conditions, error log,
Port Status LEDs,
SFPs, cables, and
loopback plugs.
Correct error
condition. Clear error
log. Rerun
diagnostics to verify
fix.
Wait a few moments
to verify that the
switch is not
initializing.
Port status LED patterns
Each port has one LED port status indicator. Table 6 on page 24 shows the LED color, status, and recommended action for these port LEDs.
Chapter 3. Operating the switch 23
Table 6. Port LED patterns during normal operation
LED name LED color Status of hardware
Port status No light No light or signal
carrier (SFP or cable) detected.
Steady green Port is online
(connected to external device) but has no traffic.
Slow-flashing green (on 1 second, off 1 second)
Fast-flashing green (on 1/4 second, off 1/4 second)
Flickering green Port is online, with
Steady amber Port is receiving light
Slow-flashing amber (on 1 second, off 1 second)
Fast-flashing amber (on 1/4 second, off 1/4 second)
Port is online but segmented, indicating a loopback cable or incompatible switch.
Port is in internal loopback (diagnostic).
traffic flowing through port.
or signal carrier but is not yet online.
Port is disabled as the result of diagnostics or
portDisable
command. If all ports are slow-flashing amber, the switch could be disabled.
Port is faulty. Check the Port Status
Recommended action
Check SFP and cable.
No action is required.
Verify that the correct device is connected to the port and that the switch and port settings are correct.
No action is required.
No action is required.
No action is required.
If all ports are slow-flashing amber, the switch could be disabled. Enable the port using the
portEnable
command; refer to
Fabric OS Command Reference Manual for
more information. If all ports are slow-flashing amber, enable the switch (switchEnable command).
LEDs, error log, SFP, and cable or loopback plug. Clear the error log. Rerun the diagnostics to verify that the error condition is fixed.
24 SAN24B-4 Express Installation, Service, and User Guide
Ethernet LED patterns
Each Ethernet port has two LEDs, which are described in Table 7
Table 7. Ethernet LED patterns
LED name LED color Status of hardware
Ethernet speed LED (right)
||| |
Ethernet link status LED (left)
|
| |
||
POST and boot specifications
When the switch is turned on or rebooted, the switch performs POST. Total boot time with POST is up to 3 minutes. POST can be omitted after subsequent reboots by using the fastboot command or entering the diagDisablePost command to persistently disable POST.
Recommended
action
No light Port speed is 10
Mb/sec.
Steady green Port speed is 100
Mb/sec.
No light No link detected Verify the Ethernet
Blinking amber There is link activity
(traffic).
Solid Amber There is a link. No action is required.
No action is required.
No action is required.
cable is connected
correctly.
No action is required.
POST
Boot
For more information about these commands, refer to the Fabric OS Command Reference Manual.
The success or failure results of the diagnostic tests that run during POST can be monitored through the error log or the command line interface.
POST includes the following steps:
1. Preliminary POST diagnostics are run.
2. Operating system is initialized.
3. Hardware is initialized.
4. Diagnostic tests are run on several functions, including circuitry, port
functionality, memory, statistics counters, and serialization.
In addition to POST, boot includes the following steps after POST is complete:
1. Universal port configuration is performed.
2. Links are initialized.
3. Fabric is analyzed, and if any ports are connected to other switches, the switch
participates in a fabric configuration.
4. Switch obtains a domain ID and assigns port addresses.
5. Unicast routing tables are constructed.
6. Normal port operation is enabled.
Chapter 3. Operating the switch 25
Interpreting POST results
POST is a system check that is performed each time the switch is powered on, rebooted, or reset. During POST, the LEDs flash amber and green. Any errors that occur during POST are listed in the error log.
To determine that POST completed successfully and whether or not any errors were detected:
1. Verify that the switch LEDs indicate that all components are healthy. See Table 4 on page 23 through Table 7 on page 25 for the description and interpretation of LED patterns. If one or more LEDs do not display a healthy state, verify that the LEDs on the switch are not set to “beacon”; use the switchShow command to detect if beaconing is active.
2. Verify that the switch prompt displays on the terminal of a computer workstation connected to the switch. If there is no switch prompt when POST completes, press Enter. If the switch prompt still does not display, try opening another telnet session or accessing through another management tool. If this is not successful, the switch did not successfully complete POST; contact IBM Service for repair.
3. Review the switch system log for errors. Any errors detected during POST are written to the system log, which is accessible through the errShow command.
For information about all referenced commands, and on accessing the error log, refer to Fabric OS Administrator's Guide. For information about error messages, refer to the Fabric OS System Error Message Reference Manual.
Switch FRU units
The only parts for this switch that are field replaceable are the SFPs. The entire switch is a FRU. The fan units and power supply are not field replaceable in this switch.
Maintaining the switch
The switch does not require any regular physical maintenance; it was designed to minimize the chance of failure. Ensure that the environmental conditions, described in “Environment considerations” on page 8, are met. This helps prevent failure of the switch due to distress or abuse.
Installing SFPs
The switch only supports Brocade-branded SFPs. If you use an unqualified SFP, the switchShow command output will show the port in an Mod_Inv state. Fabric OS will also log the issue in the system error log.
Follow these instructions to install an SFP:
1. Making sure that the bail (wire handle)B is in the unlocked position, place the SFP in the correctly oriented position on the port, as shown in Figure 9 on page 27
Note: Each SFP has a 10-pad gold-plated PCB-edge connector on the bottom.
2. Slide the SFP into the port until you feel it click into place; then close the bail.
The correct position to insert an SFP into the upper row of ports is with the gold edge down. The correct position to insert an SFP into the lower row of ports is with the gold edge up.
26 SAN24B-4 Express Installation, Service, and User Guide
1
A
B
C
2
!
A
D
Figure 9. SFP installation and bail closing
Item Description
A Switch chassis
B SFP with open bale
C SFP
C Closed bale
B24_0004
Chapter 3. Operating the switch 27
Removing SFP modules
To remove an SFP:
1. Press and hold the cable release B, as shown in section 1 of Figure 10
2. Remove the cable from the SFP, as shown in section 2.
3. Pull the bail (wire handle) D in section 3 to release the SFP.
4. Grasping it by the bail, gently but firmly pull the SFP (C in section 4) out of
the port. Attention: If the SFP you are removing does not have a bail, use a small
implement such as a screwdriver to press the release trigger beneath the port. Non-bailed SFPs can be damaged by the removal process and are not recommended. Refer to the interoperability matrix at the following web site: www.ibm.com/servers/storage/support/san for a list of supported SFPs and devices.
5. Repeat this procedure for the remaining ports, as required.
B
A
1
E
Figure 10. Removing an SFP
D
C
3
scale: 1/8" = 1"
IO
IO
!
I
k c
.
a
n
r
i
:
r
4
N
o f
6 /
h
O
t
3
I
g
1
T
n
r e l
o
N
E
w
m
e
T
r
m
c
T
5
s
A
e
m
b
u
o
m
t i x
g
a
n i t
M
n
u o
m
C
42
B24_0005
Item Description
A Switch chassis
B Cable release
28 SAN24B-4 Express Installation, Service, and User Guide
Item Description
C SFP
D Bail
E Cabled Fibre Channel ports
Testing a port, SFP, and fiber cable
The PortLoopbackTest command is used to verify the functional operation of the switch by sending frames from the port "N" transmitter and looping them back into the same port "N" receiver. The loopback is done at the parallel loopback path. The path exercised in this test does not include the media or the fiber cable. However if data transmission errors indicate that a port, SFP or cable are faulty, you can use this command to determine whether the port is faulty. You can use those results to isolate the problem to either the port or the SFP and cable combination. If a port is faulty, the switch will need to be replaced. If the port is not faulty, the problem is either with the SFP or the cable.
With this command, only one frame is transmitted and received at a time. No external cable is required to run this test. The port LEDs flicker rapidly (green) while the test is running.
The test performs the following operations:
1. Sets all ports for parallel loopback.
2. Creates a frame F of maximum data size (2,112 bytes).
3. Transmits the frame F through port "N".
4. Picks up the frame from the same port "N".
5. Checks the eight statistic error counters for nonzero values:
ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_out, BadOrdSet, DiscC3
6. Checks whether the transmit, receive, or class 3 receiver counters are stuck at some value.
7. Checks whether the number of frames transmitted is not equal to the number of frames received.
8. Repeats Steps 2 through 7 for all ports until one of the following conditions are met:
a. The number of frames (or passcount) requested is reached. b. All ports are marked bad.
At each pass, the frame is created from a different data type. If seven passes are requested, seven different data types are used in the test. If eight passes are requested, the first seven frames use unique data types, and the eighth is the same as the first. The seven data types are:
CSPAT: 0x7e, 0x7e, 0x7e, 0x7e, ... BYTE_LFSR: 0x69, 0x01, 0x02, 0x05, ... CHALF_SQ: 0x4a, 0x4a, 0x4a, 0x4a, ... QUAD_NOT: 0x00, 0xff, 0x00, 0xff, ... CQTR_SQ: 0x78, 0x78, 0x78, 0x78, ... CRPAT: 0xbc, 0xbc, 0x23, 0x47, ...
RANDOM: 0x25, 0x7f, 0x6e, 0x9a, ....
9. If the test indicates that all ports are good, the problem is associated with either the cable or SFP.
10. Replace the SFP with an SFP known to be good.
Chapter 3. Operating the switch 29
11. Simulate the data transmission scenario when the error occurred. If the error does not reappear, the original SFP was defective, and should be discarded. If the error does reappear, the cable is defective. Replace the cable and discard the original cable.
12. Simulate the data transmission scenario again to verify that the problem does
not reappear.
Diagnostic tests
In addition to POST, Fabric OS includes diagnostic tests to help troubleshoot the hardware and the firmware. This includes tests of internal connections and circuitry, fixed media, and the SFPs and cables in use. The tests are implemented by command, either through a Telnet session or through a terminal set up for a serial connection to the switch. Some tests require the ports to be connected by external cables, to allow diagnostics to verify the serializer/deserializer interface, SFP, and cable. All diagnostic tests are run at link speeds of 1, 2, 4, and 8 Gbps, depending on the speed of the link being tested.
Attention: Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing.
For information about specific diagnostic tests, refer to the Fabric OS Administrator’s Guide.
Managing the switch
You can use the management functions built into the switch to monitor the fabric topology, port status, physical status, and other information to help you analyze switch performance and to accelerate system debugging. The switch automatically performs power-on-self-test (POST) each time it is turned on. Any errors are recorded in the error log. For more information about POST, see “POST and boot specifications” on page 25.
For information about upgrading the version of Fabric OS installed on your switch, refer to the Fabric OS Administrator’s Guide. You can manage the switch using any of the management options listed in Table 8.
Table 8. Management options for the switch
Management tool Out-of-band
support
Command line interface (CLI)
Up to two admin sessions and four user sessions simultaneously. For more information, refer to the Fabric OS Administrator's Guide and the Fabric OS Command Reference Manual.
Web Tools
For information, see the Web Tools Administrator's Guide.
Standard SNMP applications
For information, see the Fabric OS MIB Reference Manual.
Fabric Manager (optional purchase) For information, refer to the Fabric Manager User’s Guide.
Management Server
For information, see the Fabric OS Administrator's Guide and the Fabric OS Command Reference Manual.
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
Ethernet or serial connection
In-band support
IP over Fibre Channel
IP over Fibre Channel
IP over Fibre Channel
IP over Fibre Channel
Native in-band interface (over HBA only)
30 SAN24B-4 Express Installation, Service, and User Guide
Table 8. Management options for the switch (continued)
Management tool Out-of-band
support
EFCM (optional purchase)
For information, refer to the EFC Manager Software User Manual.
Ethernet or serial connection
Note: To achieve in-band support for IP over Fibre Channel, the software must be
run on both the HBA and the switch, and it must be supported by both the HBA and HBA driver.
In-band support
IP over Fibre Channel
Chapter 3. Operating the switch 31
32 SAN24B-4 Express Installation, Service, and User Guide
Appendix. Product specifications
This appendix contains the following information:
v “Weight and physical dimensions” v “Environmental requirements” v “Facility requirements” on page 34 v “System specifications” on page 35 v “Memory specifications” on page 35 v “Data transmission ranges” on page 36 v “Fibre Channel port specifications” on page 36 v “Serial port specifications” on page 36 v “Power supply specifications” on page 36 v “Supported SFPs and HBAs” on page 37
Weight and physical dimensions
Table 9 lists the weight and physical dimensions of the switch.
Table 9. Physical dimensions and weight of the switch
Dimension Measurement
Height 4.29 cm (1.69 in.)
Width 42.88 cm (16.88 in.)
Depth 30.6 cm (12.07 in.)
Weight 4.2 kg (9.3 lb)
Environmental requirements
Table 10 lists the acceptable environment for both operating and nonoperating conditions.
Table 10. Environmental requirements
Condition Acceptable range during operation Acceptable range during
non-operation
Temperature -10° to + 40°C (14° to 104°F) -25° to 70°C (-13° to 158°F)
Humidity 10% to 85% RH noncondensing, at 40°C,
with maximum gradient of 10% per hour
Altitude 0 to 3 km (9,842 ft) above sea level 0 to 12 km (39,370 ft) above sea
Shock 20 G, 6 ms duration, half sine wave 33 G, 11 ms duration, half sine
Vibration 0.5 G, 5–500 Hz 2.0 G, 5–500 Hz
Air flow High speed: 23 CFM
Low speed: 18 CFM
Note: The -10° to 40° Celsius range applies to the ambient air temperature at the
air intake vents on the nonport side of the switch. The temperature inside the switch can be up to 80° Celsius during switch operation. If the internal
© Copyright IBM Corp. 2008, 2010 33
10% to 90% RH noncondensing, at 70° C
level
None required
temperature range exceeds the operating ranges of the components, the LEDs, error messages, and Fabric Watch alerts indicate a problem. Enter the tempShow or Fabric Watch commands to view temperature status.
Facility requirements
To ensure correct operation of the switch, the facility where the switch is in use must meet the requirements listed in Table 11.
Table 11. Facility requirements
Type Requirements
Electrical
Thermal
Cabinet (when rack-mounted)
v Primary AC input 100-240 VAC, 2.0A,
47-63 Hz; switch autosenses input voltage
v Adequate supply circuit, line fusing, and
wire size, as specified by the electrical rating on the switch nameplate
v Correctly wired primary outlet, with
circuit protected by a circuit breaker and grounded in accordance with local electrical codes
v A minimum air flow of 24 cubic ft/min
available to the air intake vents on the nonport side of the switch.
v Ambient air temperature not exceeding
40° C (104° F) while the switch is operating
v At a minimum, adequate cooling requires
that you install the switch with the nonport side, which contains the air intake vents, facing the cool-air aisle
v All equipment in the rack should force air
in the same direction to avoid intaking exhaust air
v Ensure that airflow and temperature
requirements are met on an ongoing basis, particularly if the switch is installed in a closed or multicabinet assembly
v One rack unit in a standard EIA 19-in.
(48.3 cm) cabinet
v All equipment in cabinet grounded
through a reliable branch circuit connection and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip
v Additional weight of switch not to exceed
the cabinet’s weight limits
v Cabinet secured to ensure stability in case
of unexpected movement, such as an earthquake
34 SAN24B-4 Express Installation, Service, and User Guide
System specifications
Table 12 lists the system specifications for the switch.
Table 12. General specifications
Specification Descriptions
Autoconfiguring port types F_Port, FL_Port, M_Port, N_Port, and E_Port
System architecture Nonblocking shared-memory switch
System processor IBM PowerPC 440EPx, 667 MHz
SDRAM 512 MB DDR2 SDRAM onboard memory
Compact flash 1 GB
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and
Modes of operation Fibre Channel Class 2, Class 3, Class F
Fabric initialization Complies with FC-SW-2 6.6
Ethernet port One 10/100BaseT Ethernet port; accessed
Terminal port One UART interface for terminal, accessed
ASIC Goldeneye-2 ASIC for Fibre Channel
Port Status LEDs 24 LEDs (green/amber) to indicate status for
System Power LED One LED (green) to indicate system power
System Status LED One LED (green/amber) to indicate system
Ethernet LEDs Two Ethernet LEDs to indicate speed and
Power supply One fixed power supply (not a FRU)
Fans Three fixed fans operating at dual speeds
FC-IP (IP over Fibre Channel) Complies with FC-IP 2.3 of FCA profile
Aggregate switch I/O bandwidt 384 Gbps if all 24 ports running at 8 Gbps,
Port-to-port latency Less than 700 nanoseconds with no
operating at 133 MHz
Signalling Interface standard)
through RJ45 connector
through RJ-45 connector
Switching
each port
status
link status
(not a FRU).
full duplex
contention (destination port is free)
Memory specifications
The switch memory specifications are shown in Table 13.
Table 13. Memory specifications
Memory type Installed memory
Main memory (SDRAM) 512 MB
Compact flash 1 GB
Appendix. Product specifications 35
Data transmission ranges
Table 14 provides the data transmission ranges for different cable types and port speeds.
Table 14. Data transmission ranges
Port speed Cable size (microns) Short wavelength (SWL) Long wavelength (LWL)
1 Gbps 50 500 m (1,640 ft) N/A
62.5 300 m (984 ft) N/A
9 N/A up to 10 km (6.2 mi)
2 GGbps 50 300 m (984 ft) N/A
62.5 150 m (492 ft) N/A
9 N/A N/A
4 Gbps 50 150 m (492 ft) N/A
62.5 70 m (230 ft) N/A
9 N/A N/A
8 Gbps 50 150 m (492 ft) N/A
62.5 21 m (69 ft) N/A
9 N/A 10 km
Fibre Channel port specifications
The Fibre Channel ports in the switch are compatible with SWL, LWL, and ELWL SFPs. The strength of the signal is determined by the type of SFP in use. The ports are capable of operating at 1, 2, 4 and 8 Gbps, and are able to autosense the highest speed capable for all attached devices. The ports meet all required safety standards.
Serial port specifications
The serial port is located on the port side of the switch as a RJ-45 connector, designed to connect to a DTE port. Use the serial port to connect to a computer workstation to configure the switch IP address without connecting to the fabric. The serial port’s parameters are 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.
Power supply specifications
The power supply is universal and capable of functioning worldwide without using voltage jumpers or switches. It meets IEC 61000-4-5 surge voltage requirements and is autoranging in terms of accommodating input voltages and line frequencies. The power supply has its own built-in fan for cooling, pushing the air toward the port side of the switch. The power supply is not removable.
Table 15 lists the power supply specifications for the switch.
Table 15. Switch power supply specifications
Specification Value
Inlet C13
Maximum output from the power supply 75 watts
36 SAN24B-4 Express Installation, Service, and User Guide
Table 15. Switch power supply specifications (continued)
Specification Value
System power consumption 48 watts nominal, 57 watts maximum
Input voltage 85 - 264 VAC, universal
Input line frequency 47 - 63 Hz
BTU rating 277 BTU/hr
Inrush current 21.5 Amps at 240 VAC cold start
Supported SFPs and HBAs
When you receive the switch, your package contains at least 8 Brocade-branded SFPs for the base configuration. Use only SFPs that are tested and supported. For the most up to date list of supported SFPs and HBAs for the switch, refer to the product interoperability matrix at the IBM SAN Support web pages at: www.ibm.com/servers/storage/support/san
Appendix. Product specifications 37
38 SAN24B-4 Express Installation, Service, and User Guide
Notices
This information was developed for products and services offered in the USA.
IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe on any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing to:
IBM Director of Licensing IBM Corporation North Castle Drive Armonk, N.Y. 10504-1785 U.S.A.
For additional information, visit the web at: http://www.ibm.com/ibm/licensing/contact/
The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
Any references in this information to non-IBM web sites are provided for convenience only and do not in any manner serve as an endorsement of those web sites. The materials at those web sites are not part of the materials for this IBM product and use of those web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level
© Copyright IBM Corp. 2008, 2010 39
systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.
If you are viewing this information in softcopy, the photographs and color illustrations may not appear.
40 SAN24B-4 Express Installation, Service, and User Guide
Trademarks
IBM, the IBM logo, and ibm.com®are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml
Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.
Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
®
Linux
is a registered trademark of Linus Torvalds in the United States, other
countries, or both.
®
Microsoft
and Windows are trademarks of Microsoft Corporation in the United
States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other countries.
Other product and service names might be trademarks of IBM or other companies.
Notices 41
Electronic emission notices
The following statements apply to this product. The statements for other products intended for use with this product will appear in their accompanying manuals.
Federal Communications Commission (FCC) Class A Statement
This equipment has been tested and complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Industry Canada Class A Emission Compliance Statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d'Industrie Canada
Cet appareil numérique de la classe A est conform à la norme NMB-003 du Canada.
European Union EMC Directive Conformance Statement
This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards.
Attention: This is an EN55022 Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Responsible manufacturer: International Business Machines Corp. New Orchard Road Armonk, New York 10504 Tel: 919-499-1900
European community contact: IBM Technical Regulations, Department M456
42 SAN24B-4 Express Installation, Service, and User Guide
IBM-Allee 1, 71137 Ehningen, Germany Tel: +49 7032 15-2937 E-mail: tjahn@de.ibm.com
Germany Electromagnetic Compatibility Directive
Deutschsprachiger EU Hinweis:
Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen Verträglichkeit
Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein.
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung der IBM gesteckt/eingebaut werden.
EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden: "Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funk-Störungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen zu ergreifen und dafür aufzukommen."
Deutschland: Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Geräten
Dieses Produkt entspricht dem "Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG)". Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG in der Bundesrepublik Deutschland.
Zulassungsbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG) (bzw. der EMC EG Richtlinie 2004/108/EG) für Geräte der Klasse A
Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen - CE - zu führen.
Verantwortlich für die Einhaltung der EMV Vorschriften ist der Hersteller: International Business Machines Corp. New Orchard Road Armonk, New York 10504 Tel: 919-499-1900
Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland Technical Regulations, Department M456 IBM-Allee 1, 71137 Ehningen, Germany Tel: +49 7032 15-2937 E-mail: tjahn@de.ibm.com
Notices 43
Generelle Informationen:
Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
People's Republic of China Class A Electronic Emission Statement
Japan VCCI Council Class A Statement
Translation: This is a Class A product based on the standard of the VCCI Council. If this equipment is used in a domestic environment, radio interference may occur, in which case, the user may be required to take corrective actions.
44 SAN24B-4 Express Installation, Service, and User Guide
Japan Electronics and Information Technology Industries Association (JEITA) Statement
Japanese Electronics and Information Technology Industries Association (JEITA) Confirmed Harmonics Guideline (products less than or equal to 20 A per phase).
Korea Communications Commission (KCC) Statement
Please note that this equipment has obtained EMC registration for commercial use. In the event that it has been mistakenly sold or purchased, please exchange it for equipment certified for home use.
Russia Electromagnetic Interference (EMI) Class A Statement
Australia and New Zealand Class A Statement
Attention: This is a Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures.
Notices 45
46 SAN24B-4 Express Installation, Service, and User Guide
Index
A
About this document xiii accessibility
IBM commitment iv keyboard navigation iv vendor software iv
address
IBM v
air flow
requirements 33
altitude
requirements 33
attention notice
definition xix example xix
attention notices xix
B
boot
specifications 25 Boot steps 25 Brocade
documents xiii Brocade documents xiii
C
cabinet
considerations 8
installation 9
requirements 8, 34 cable management
recommendations 15 caution notices xvii
definition xvii
examples xviii CLI
management 30 command line interface (CLI)
management 30 comments, sending to IBM iv configurations
fabric 3
supported 3 configuring
switch 7, 16 connectivity
supported 2 considerations
cabinet 8
electrical 8
environmental 8
rack 8 creating a serial connection 17
D
danger notices xv
definitions xv examples xv
date
setting 18
default
password 17
diagnostic
tests 30 director of licensing, address 39 disposal xxii documentation xiii documents
Brocade xiii
E
edition notice ii EFCM
management 30 electrical
considerations 8
requirements 8, 34 electrical requirements 8 electronic emission notices 42 environmental
considerations 8
notices xxii
product recycling and disposal xxii
requirements 8, 33 environmental notices xiv environmental requirements 33 Ethernet port
LED patterns 25 Ethernet status
LED 21 EZSwitch setup
installation 16
F
fabric
configurations 3 Fabric Manager
management 30 facility requirements 34 features
1U chassis 1
auto-sensing Fibre Channel ports 1
built-in fans 1
built-in power supply 1
Dynamic Path Selection (DPS) 1
Ethernet port 1
EZSwitchSetup wizard 1
Inter-Switch-Link trunking 1
LEDs 1
NPIV access gateway 1
optional 4
RJ45 Ethernet management port 1
features (continued)
USB port 1
fiber cable
testing 29
Fibre Channel port
specifications 36 field replaceable unit (FRU) 26 FRUs 26
G
general specifications 35 getting help iii
H
help iii humidity
requirements 33
I
IBM
accessibility commitment iv
address v
interoperability matrix 37
notices 39
trademarks 41 in-band support 30 installation
EZSwitch setup 16
slide-rail
instructions 10
switch
instructions 10
installing
electrical requirements 8
facility requirements 34
SFP 26
slide-rail rack 8, 9
stand-alone switch 9
stand-alone unit 8, 9
switch 7 installing the switch 8 instructions
installation 10 intellectual property 39 interpreting LED activity 21 Interpreting POST results 26 Interswitch Link (ISL) 3 IP address
setting 17
static 17
using DHCP 17 ISL
trunking groups 3 items included 7
© Copyright IBM Corp. 2008, 2010
47
K
keyboard navigation iv
L
labels, safety xix LED
activity 21 descriptions 2 Ethernet status 21 interpretation 21 locations 2, 22 patterns 23 system power 21 system status 21 types 21
LED patterns
Ethernet port 25 port status 23 power status 23 system status 23
license
agreement iv license, for patents 39 local time
synchronizing 19
using NTP 19
M
maintaining
switch 26 maintenance
switch 26 management
CLI 30
EFCM 30
Fabric Manager 30
in-band 30
Management Server 30
SNMP 30
Web Tools 30 management features 30 Management Server
management 30 managing
cables 15 memory 35
N
network time protocol (NTP)
time synchronization 19 nonport side
switch 3 notice, edition ii notices
attention xix
caution xvii
danger xv
environmental xiv, xxii
general 39
IBM 39
patents 39
safety xiv
notices (continued)
types xv notices ,danger xv notices and labels
safety xiv NTP
time synchronization 19
P
parts supplied with switch rack-mount
kit 11
password
default 17 patents 39 physical dimensions 33 port
activation 3
descriptions 2
Ethernet 2
Fibre Channel 2
locations 2
system console 2
testing 29
USB 2 port side
LEDs 22
switch 2 port status
LED 21
LED patterns 23 POST
interpreting results 26
specifications 25 POST and boot specifications 25 POST steps 25 power
consumption 36
switch 16 power status
LED patterns 23 power supply
BTU rating 36
inlet connector 36
input line frequency 36
input voltage 36
inrush current 36
maximum output 36
specifications 36 product
documentation xiii product specifications 33
data transmission ranges 36
environmental requirements 33
Fibre Channel ports 36
Q
qualified
SFPs 26
R
rack
considerations 8
requirements 8
rack (continued)
safety xx rack mount kit 11 rack relocation
safety xxi rack safety xx read this first iii recycling xxii removing
SFP 28 requirements
air flow 33
altitude 33
cabinet 34
cacbinet 8
electrical 8, 34
environmental 8, 33
humidity 33
rack 8
shock 33
temperature 33
thermal 34
vibration 33 results
POST 26
S
safety xiv
considerations 8
labels xiv, xix
examples xix notices xiv rack xx rack installation xx rack relocation xxi
safety labels xix safety notices xiv serial connection
creating 17 UNIX 17 Windows 17
serial port
specifications 36
setting
date 18 IP address 17 time 18 time zones 18
setting the IP address 17 SFP
bail 26, 28 FRUs 26 installing 26 removing 28 supported 37 supported types 26 testing 29
shock
requirements 33
SNMP
management 30
specifications
boot 25 data transmission ranges 36 Fibre Channel ports 36 general 35
48 SAN24B-4 Express Installation, Service, and User Guide
specifications (continued)
memory 35 physical dimensions 33 POST 25 power supply 36 product 33 serial port 36 system 35 weight 33
stand-alone
switch 9
installing 9
static IP address
setting 17
supported
SFPs 26 supported (optional) features 4 supported connectivity 2 switch
airflow 3
cabinet 9
configuring 7, 16
features 1
See features FRU units 26 installing 7, 9 introduction 1 items included 7 library xiii maintaining 26 maintenance 26 management features 30 memory 35 nonport side 3 parts supplied with the rack-mount
kit 11 physical dimensions 33 port side 2 power 16 powering on and off 21 product specifications
See product specifications specifications 35 stand-alone 9 weight 33
synchronizing
local time 19
system power
LED 21
system specifications 35 system status
LED 21 LED patterns 23
time
setting 18
time zones
setting 18 trademarks 41 trunking groups
ISL 3
V
vendor software iv vibration
requirements 33
W
Web sites iii Web Tools
management 30 weight 33
T
temperature
requirements 33 terminal emulator applications 17 testing
fiber cable 29
port 29
SFP 29 tests
diagnostic 30 thermal
requirements 34
Index
49
50 SAN24B-4 Express Installation, Service, and User Guide

Part Number: 45W8145
Printed in USA
GA32-0580-02
(1P) P/N: 45W8145
Service information: 2498
-B24,24E
SAN24B-4 Express Installation, Service, and User
IBM System Storage SAN24B-4
Guide
Express