OSR IBM 4033/Lexmark MarkNet
Models 001, 002, 003, 011, 012, and 013:
Adapter
Models 201, 301, 202, and 302:
Models 0XX, 2XX, 3XX
Network Operating System Requirements
Connectivity IBM 4033 Models 1 and 11: IBM Token-Ring (IEEE
Printer and Plotter Port Data Rates
Printer and Plotter Cables (not included)
IBM 4033 Models 1 and 11 (Token-Ring)
IBM 4033 Models 2 and 12 (Ethernet 10BaseT)
IBM 4033 Models 3 and 13 (Ethernet 10Base5 or 10Base2)
IBM 4033 Models 1, 2, and 3: IBM OS/2 LAN Server 1.2,
1.3, and 2.0; Microsoft LAN Manager 2.0 and 2.1; IBM
AIX for RISC System/6000 Version 3.1.5
IBM 4033 Models 11, 12, and 13: Novell Netware 2.2 and
3.11; Netware from IBM 2.2 and 3.11; Netware for
AIX/6000 from IBM Version 3.11
802.5)
IBM 4033 Models 2 and 12: Ethernet 10BaseT (IEEE
*
802.3)
IBM 4033 Models 3 and 13: Ethernet 10Base2 and
10Base5 (IEEE 802.3)
Up to 150Kbytes per second (parallel) with IBM 4029
LaserPrinter Fastbytes mode
Up to 38.4Kbits per second (serial)
25-pin parallel (printers); 9-pin serial adapter; 25-pin
serial (printers); 36-pin Centronics (printers); 25-pin serial
(plotters)
9-pin D-shell connector: PC Adapter cable with ring data
rate of 4 or 16Mbps; Type 3 media filter cable; telephone
twisted pair with ring rate of 4Mbps
8-pin RJ-45 connector; unshielded twisted-pair telephone
cable
10Base5 AUI connector and 10Base2 BNC T-connector;
10Base2 BNC jack; RG-58 coaxial cable; 10Base5 15-pin
D-shell connector; attachment unit interface (AUI) cable
*
Limited Warranty One year
Self-test
Start
The following tests describe what might be wrong if an error occurs and what action
to take.
Note:
If the adapter is replaced, the customer must delete all associations after
removing the adapter from the LAN. When the replacement adapter is connected to
the LAN, the customer must perform the configuration steps and establish new
associations.
Power
The power LED should always be on when there is power to the adapter. If the
power LED is off:
On Models 0XX, make sure the green dot faces up on the power cord to the
adapter. Check for +5VDC and +1 2VDC the power supply connector (US Models
001, 002, 01 011, and 012 have only +5VDC). Pin 2 is ground. If the power to the
adapter is correct, replace the operator panel board.
On Models 2XX and 3XX, if the power to the adapter is correct, replace the
adapter.
Reset, LAN Connected
To reset the adapter, press the Reset button.
Models 0XX:
The status LED should blink several times within 3 to 4 seconds, turn off for up to
30 seconds, then turn on solid.
Models 20X and 30X:
The following LED sequence occurs during a normal reset. A successful reset
results in the Power and Status LEDs on and the Test and Data LEDs off.
Status Test Data
off off off
on on on
off on on
*
Models 12 and 13 also support Ethernet Type II (AIX).
Status Test Data
off on off
off off off
on off off
If an error is detected the LEDs will hang in their current state. Reset again and
replace the adapter if the error recurs.
Common Problems and Fixes
Model 0XX:
Symptom Action
Status LED on The adapter is functioning correctly. Go to “Wrap
Status LED blinking There is a problem with the adapter or the LAN. Go to
Status LED off Replace the operator panel board. If the problem
Test for Adapter Ports” on page 2.
“LAN Connection Check” on page 2.
recurs, replace the adapter.
95-05-26
All rights reserved. LM-4 1

IBM 4033/Lexmark MarkNet OSR
Models 2XX, 3XX:
The Status LED blinks to indicate an error was detected after a successful Reset.
The Test and Data LEDs indicate what type of error was detected:
Status Test Data Error Action
blink off off software Contact next
blink off on network Refer to
Note:
If you are updating the flash code, the Status, Test, and Data LEDs will all
blink. This does not indicate an error.
level of
support.
Printer and
LAN Checks.
Sample Print Test (Models 20X and 30X)
Press and release the Test button to send a single-page file to all ports. If the test is
successful, go to “LAN Connection Check.” If the print test fails, go to “Wrap Test
for Adapter Ports.”
Wrap Test for Adapter Ports
To test any port:
1. Disconnect the printer cable from the adapter.
2. Install a wrap plug on that port.
3. Press Reset.
Models 0XX:
The Status LED will blink several times within 3 to 4 seconds, turn off for up to 10
seconds, then blink continuously in a pattern of two blinks, a pause, then two blinks.
Any other pattern on blinks indicates a failure of the Replace the adapter if the test
fails.
Models 20X and 30X:
Status Test Data Failure
off off blink Parallel 1 port wrap failure
off blink off Parallel 2 port wrap failure
off blink blink Serial port wrap failure
A successful test results in only the Power and Status LEDs on, just like a normal
Reset. Replace the adapter if the test fails.
LAN Connection Check
1. For Token-Ring using shielded twisted-pair cable (Models 001, 011, 201,
or 301): Disconnect the LAN cable from the network, leaving it connected to
the adapter.
For Ethernet 10Base2 (Models 003, 013, 202, or 302): Make sure the switch
is set to position 2 for Models 003 and 013, or position 16/2 for Models 202
and 302. Attach a 50 ohm BNC terminator cap to each end of the T-connect
or. (The customer may be able to supply these caps.)
For Token-Ring using unshielded twisted-pair cable (Models 201 or 301 )
or Ethernet 1 10BaseT (Models 002, 012, 202, or 302): There is no LAN connection test for these configurations. Refer to “Printer and LAN checks.”
2. Press the Reset button.
Models 0XX:
The status LED will blink several times within 3-4 seconds, turn off for up to
30 seconds, then turn on solid.
Models 20X and 30X:
The adapter will go through a reset cycle and stop with on the Power and
Status LEDs on.
Any other result indicates a failure of the test. For Token-Ring using shielded
twisted-pair cable, verify the continuity of the cable and replace the adapter if
the cable is good. For Ethernet 1 10Base2 replace the adapter.
Printer and LAN checks
Reset Cycle
Test Power Status Test Data
1 on off off off
2 on on on on
3 on off on on
4 on off on off
5 on off off on
6 on off off off
End on on off off
If the adapter checks out successfully, the problem may be with other hardware or
software on the network. The following
are suggestions to the customer for checking hardware and software for possible
problems.
Printer checks
Make sure the printer is operating correctly by running printer diagnostics and
the printer wrap test.
Make sure the printer is configured for the right type of port (parallel or serial).
Make sure the jumper and power cords are properly connected.
Make sure the printer is queued and the printer driver is configured properly.
Make sure the proper adapter port has been associated (parallel or serial).
Make sure the adapter's printer port parameters match those of the printer (for
example, parallel mode, serial baud rate, and serial protocol).
LAN checks
Make sure the software utility has been correctly installed.
Make sure the LAN cable and LAN connections are good.
Make sure a single route broadcast is supported across the network bridges, if a
bridge is used.
Make sure the server is working properly. Review print server installation and
configuration using the appropriate system guide to operation.
Parts Catalog
2XX, 3XX Models
P/N Description
1381605 4033- 201 Token-Ring network adapter
1381603 4033- 202 Ethernet network adapter
1381606 4033- 301 Token-Ring network adapter with serial port
1381604 4033- 302 Ethernet network adapter with serial port
1418613 Cover, switch
1418601 Cord set, jumper power
2182994 T-connector, Ethernet
9900769 Wrap plug, parallel
9900770 Wrap plug, serial
72X8546 Wrap plug, multifunction
0XX Models
P/N Description
1333658 Adapter Asm., Model 4033-001 (no P/S)
1333588 Adapter Asm., Model 4033-002 (no P/S)
1333589 Adapter Asm., Model 4033-003 (no P/S)
1333787 Adapter Asm., Model 4033-011 (no P/S)
1333788 Adapter Asm., Model 4033-012 (no P/S)
1333789 Adapter Asm., Model 4033-013 (no P/S)
1333586 Operator Panel Board, 4033-001, 4033-011,
1333595 Operator Panel Board, 4033-002, 4033-003, 4033-012,
1333590 Power Supply, US Model 4033-001, 4033-002, 4033-011,
1333591 Power Supply, US Model 4033-003, 4033-013, WT (except
1333592 Power Supply, Nordic
0XX Models (Continued)
P/N Description
72X8546 Wrap Plug, multi-function
71F1168 Terminator Cap, 25 Ohm, BNC
1339517 Line Cord, US, Canada, Columbia, Saudi Arabia
6185888 Line Cord, US, 6 ft.
1339520 Line Cord, Europe
1339523 Line Cord, South Africa
1339522 Line Cord, Switzerland
1339524 Line Cord, Italy
1339525 Line Cord, Denmark
1339518 Line Cord, New Zealand/Australia, Argentina, Uruguay
1339521 Line Cord, Israel
1339519 Line Cord, UK
1339523 Line Cord, Pakistan
1339519 Line Cord, Hong Kong, Malaysia, Singapore, Burma, Brunei,
1339523 Line Cord, Bangladesh, Sri Lanka
4033-013
4033-012
Nordic)
India
2 LM-4 IBM/TSS Internal Use Only