IBM 4033, IBM 4033 1, IBM 4033 2, IBM 4033 3, IBM 4033 11 User Manual

...
OSR IBM 4033/Lexmark MarkNet
Models 001, 002, 003, 011, 012, and 013:
Adapter
Models 201, 301, 202, and 302:
Models 0XX, 2XX, 3XX Network Operating System Requirements
Connectivity IBM 4033 Models 1 and 11: IBM Token-Ring (IEEE
Printer and Plotter Port Data Rates
Printer and Plotter Cables (not included)
IBM 4033 Models 1 and 11 (Token-Ring)
IBM 4033 Models 2 and 12 (Ethernet 10BaseT)
IBM 4033 Models 3 and 13 (Ethernet 10Base5 or 10Base2)
IBM 4033 Models 1, 2, and 3: IBM OS/2 LAN Server 1.2,
IBM 4033 Models 11, 12, and 13: Novell Netware 2.2 and
3.11; Netware from IBM 2.2 and 3.11; Netware for AIX/6000 from IBM Version 3.11
802.5) IBM 4033 Models 2 and 12: Ethernet 10BaseT (IEEE
*
802.3) IBM 4033 Models 3 and 13: Ethernet 10Base2 and
10Base5 (IEEE 802.3)
Up to 150Kbytes per second (parallel) with IBM 4029 LaserPrinter Fastbytes mode
Up to 38.4Kbits per second (serial)
25-pin parallel (printers); 9-pin serial adapter; 25-pin serial (printers); 36-pin Centronics (printers); 25-pin serial (plotters)
9-pin D-shell connector: PC Adapter cable with ring data rate of 4 or 16Mbps; Type 3 media filter cable; telephone twisted pair with ring rate of 4Mbps
8-pin RJ-45 connector; unshielded twisted-pair telephone cable
10Base5 AUI connector and 10Base2 BNC T-connector; 10Base2 BNC jack; RG-58 coaxial cable; 10Base5 15-pin D-shell connector; attachment unit interface (AUI) cable
*
Limited Warranty One year
Self-test
Start
The following tests describe what might be wrong if an error occurs and what action to take.
Note:
If the adapter is replaced, the customer must delete all associations after removing the adapter from the LAN. When the replacement adapter is connected to the LAN, the customer must perform the configuration steps and establish new associations.
Power
The power LED should always be on when there is power to the adapter. If the power LED is off:
On Models 0XX, make sure the green dot faces up on the power cord to the adapter. Check for +5VDC and +1 2VDC the power supply connector (US Models 001, 002, 01 011, and 012 have only +5VDC). Pin 2 is ground. If the power to the adapter is correct, replace the operator panel board.
On Models 2XX and 3XX, if the power to the adapter is correct, replace the adapter.
Reset, LAN Connected
To reset the adapter, press the Reset button.
Models 0XX:
The status LED should blink several times within 3 to 4 seconds, turn off for up to 30 seconds, then turn on solid.
Models 20X and 30X:
The following LED sequence occurs during a normal reset. A successful reset results in the Power and Status LEDs on and the Test and Data LEDs off.
Status Test Data
off off off on on on off on on
*
Models 12 and 13 also support Ethernet Type II (AIX).
Status Test Data
off on off off off off on off off
If an error is detected the LEDs will hang in their current state. Reset again and replace the adapter if the error recurs.
Common Problems and Fixes
Model 0XX:
Symptom Action
Status LED on The adapter is functioning correctly. Go to “Wrap
Status LED blinking There is a problem with the adapter or the LAN. Go to
Status LED off Replace the operator panel board. If the problem
Test for Adapter Ports” on page 2.
“LAN Connection Check” on page 2.
recurs, replace the adapter.
95-05-26 All rights reserved. LM-4 1
IBM 4033/Lexmark MarkNet OSR
Models 2XX, 3XX:
The Status LED blinks to indicate an error was detected after a successful Reset. The Test and Data LEDs indicate what type of error was detected:
Status Test Data Error Action
blink off off software Contact next
blink off on network Refer to
Note:
If you are updating the flash code, the Status, Test, and Data LEDs will all
blink. This does not indicate an error.
level of support.
Printer and LAN Checks.
Sample Print Test (Models 20X and 30X)
Press and release the Test button to send a single-page file to all ports. If the test is successful, go to “LAN Connection Check.” If the print test fails, go to “Wrap Test for Adapter Ports.”
Wrap Test for Adapter Ports
To test any port:
1. Disconnect the printer cable from the adapter.
2. Install a wrap plug on that port.
3. Press Reset.
Models 0XX:
The Status LED will blink several times within 3 to 4 seconds, turn off for up to 10 seconds, then blink continuously in a pattern of two blinks, a pause, then two blinks. Any other pattern on blinks indicates a failure of the Replace the adapter if the test fails.
Models 20X and 30X:
Status Test Data Failure
off off blink Parallel 1 port wrap failure off blink off Parallel 2 port wrap failure off blink blink Serial port wrap failure
A successful test results in only the Power and Status LEDs on, just like a normal Reset. Replace the adapter if the test fails.
LAN Connection Check
1. For Token-Ring using shielded twisted-pair cable (Models 001, 011, 201, or 301): Disconnect the LAN cable from the network, leaving it connected to the adapter.
For Ethernet 10Base2 (Models 003, 013, 202, or 302): Make sure the switch is set to position 2 for Models 003 and 013, or position 16/2 for Models 202 and 302. Attach a 50 ohm BNC terminator cap to each end of the T-connect or. (The customer may be able to supply these caps.)
For Token-Ring using unshielded twisted-pair cable (Models 201 or 301 ) or Ethernet 1 10BaseT (Models 002, 012, 202, or 302): There is no LAN con­nection test for these configurations. Refer to “Printer and LAN checks.”
2. Press the Reset button.
Models 0XX:
The status LED will blink several times within 3-4 seconds, turn off for up to 30 seconds, then turn on solid.
Models 20X and 30X:
The adapter will go through a reset cycle and stop with on the Power and Status LEDs on.
Any other result indicates a failure of the test. For Token-Ring using shielded twisted-pair cable, verify the continuity of the cable and replace the adapter if the cable is good. For Ethernet 1 10Base2 replace the adapter.
Printer and LAN checks
Reset Cycle
Test Power Status Test Data
1 on off off off 2 on on on on 3 on off on on 4 on off on off 5 on off off on 6 on off off off End on on off off
If the adapter checks out successfully, the problem may be with other hardware or software on the network. The following are suggestions to the customer for checking hardware and software for possible problems.
Printer checks
Make sure the printer is operating correctly by running printer diagnostics and the printer wrap test.
Make sure the printer is configured for the right type of port (parallel or serial). Make sure the jumper and power cords are properly connected. Make sure the printer is queued and the printer driver is configured properly. Make sure the proper adapter port has been associated (parallel or serial). Make sure the adapter's printer port parameters match those of the printer (for
example, parallel mode, serial baud rate, and serial protocol).
LAN checks
Make sure the software utility has been correctly installed. Make sure the LAN cable and LAN connections are good. Make sure a single route broadcast is supported across the network bridges, if a
bridge is used. Make sure the server is working properly. Review print server installation and
configuration using the appropriate system guide to operation.
Parts Catalog
2XX, 3XX Models
P/N Description
1381605 4033- 201 Token-Ring network adapter 1381603 4033- 202 Ethernet network adapter 1381606 4033- 301 Token-Ring network adapter with serial port 1381604 4033- 302 Ethernet network adapter with serial port 1418613 Cover, switch 1418601 Cord set, jumper power 2182994 T-connector, Ethernet 9900769 Wrap plug, parallel 9900770 Wrap plug, serial 72X8546 Wrap plug, multifunction
0XX Models
P/N Description
1333658 Adapter Asm., Model 4033-001 (no P/S) 1333588 Adapter Asm., Model 4033-002 (no P/S) 1333589 Adapter Asm., Model 4033-003 (no P/S) 1333787 Adapter Asm., Model 4033-011 (no P/S) 1333788 Adapter Asm., Model 4033-012 (no P/S) 1333789 Adapter Asm., Model 4033-013 (no P/S) 1333586 Operator Panel Board, 4033-001, 4033-011, 1333595 Operator Panel Board, 4033-002, 4033-003, 4033-012,
1333590 Power Supply, US Model 4033-001, 4033-002, 4033-011,
1333591 Power Supply, US Model 4033-003, 4033-013, WT (except
1333592 Power Supply, Nordic
0XX Models (Continued)
P/N Description
72X8546 Wrap Plug, multi-function 71F1168 Terminator Cap, 25 Ohm, BNC 1339517 Line Cord, US, Canada, Columbia, Saudi Arabia 6185888 Line Cord, US, 6 ft. 1339520 Line Cord, Europe 1339523 Line Cord, South Africa 1339522 Line Cord, Switzerland 1339524 Line Cord, Italy 1339525 Line Cord, Denmark 1339518 Line Cord, New Zealand/Australia, Argentina, Uruguay 1339521 Line Cord, Israel 1339519 Line Cord, UK 1339523 Line Cord, Pakistan 1339519 Line Cord, Hong Kong, Malaysia, Singapore, Burma, Brunei,
1339523 Line Cord, Bangladesh, Sri Lanka
4033-013
4033-012
Nordic)
India
2 LM-4 IBM/TSS Internal Use Only