IBM AT-FS202SC-FS2, AT-FS202SC-FS3, AT-FS202SC-FS1, AT-FS202, AT-FS201 User Manual

...
AT-FS201 AT-FS202 AT-FS202SC/FS1 AT-FS202SC/FS2 AT-FS202SC/FS3 AT-FS202SC/FS4
Fast Ethernet Series Switches
Installation Guide
PN 613-10761-00 Rev E
Copyright © 2004 Allied Telesyn International, Corp.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.

Electrical Safety and Emission Compliance Statement

Standards: This product meets the following standards.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission EN55022 Class A 1 Warning: In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Immunity EN55024 3 Warning: This product requires shielded cables to comply with emission
and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
Electrical Safety EN60950, UL1950, CSA 950 5 Laser EN60825 6 Warning Class 1 Laser product. 7 Warning Do not stare into the Laser beam. 8
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
This is a “Class 1 LED Product” (AT-FS201, AT-FS202 models) 9
2
4
iii
Electrical Safety and Emission Compliance Statement
Important: Appendix B contains translated safety statements for installing this equipment. When you see the safety statement in your language.
Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt: Tillæg B indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når De ser symbolet B og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix B bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur. Wanneer u de Appendix B voor vertaalde veiligheidsinstructies in uw taal.
Important: L'annexe B contient les instructions de sécurité relatives à l'installation de cet équipement. Lorsque vous voyez le symbole reportez-vous à l'annexe B pour consulter la traduction de ces instructions dans votre langue.
Tärkeää: Liite B sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet liitteestä B.
Importante: l’Appendice B contiene avvisi di sicurezza tradotti per l’installazione di questa apparecchiatura. Il simbolo l’Appendice B per l’avviso di sicurezza nella propria lingua.
Viktig: Tillegg B inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser oversatte sikkerhetsinformasjonen på ønsket språk.
Importante: O Anexo B contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo segurança traduzida no seu idioma no Anexo B.
Importante: El Apéndice B contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo Apéndice B para ver el mensaje de seguridad traducido a su idioma.
Obs! Bilaga B innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser för att läsa det översatta säkerhetsmeddelandet på ditt språk.
-symbolin, katso käännettyä turvaohjetta
, go to Appendix B for the translated
sehen, schlagen Sie in Anhang B
, åpner du til Tillegg B for å finne den
, skal De slå op i tillæg
ziet, raadpleeg
,
, indica di consultare
, leia a advertência de
, vaya al
, skall du gå till Bilaga B
iv

Table of Contents

Electrical Safety and Emission Compliance Statement ......................iii
Welcome to Allied Telesyn .........................................................................vii
Where to Find Web-based Guides ..................................................................vii
Document Conventions ...................................................................................vii
Contacting Allied Telesyn ..............................................................................viii
Online Support ........................................................................................viii
Email and Telephone Support ................................................................viii
For Sales or Corporate Information .......................................................viii
Chapter 1
Description ...................................................................................................... 1
Key Features ...................................................................................................... 4
Status LEDs ....................................................................................................... 4
Twisted-Pair Port .............................................................................................. 5
Port Speed ................................................................................................... 5
Duplex Mode ...............................................................................................5
Auto MDI/MDI-X ........................................................................................ 6
Fiber Optic Port ................................................................................................. 6
Port Speed ................................................................................................... 6
Duplex Mode ...............................................................................................6
Switch Performance ...........................................................................................7
DIP Switches ..............................................................................................7
MAC Address Table .................................................................................... 7
Store and Forward ...................................................................................... 8
External AC/DC Power Adapter ................................................................ 8
Network Topologies ...........................................................................................8
Chapter 2
Installing the Switch ................................................................................... 11
Verifying Package Contents ............................................................................11
Planning the Installation ................................................................................12
Selecting a Site .........................................................................................14
Installing the Switch .......................................................................................15
Warranty Registration ....................................................................................17
v
Table of Contents
Chapter 3
Troubleshooting ...........................................................................................19
Appendix A
Technical Specifications ............................................................................21
Physical ............................................................................................................21
Temperature ....................................................................................................21
Electrical Rating ..............................................................................................21
Agency Certifications .......................................................................................22
Fiber Optic Port Specifications .......................................................................22
Pinout Assignments .........................................................................................24
Appendix B
Translated Safety and Emission Information .......................................27
vi

Welcome to Allied Telesyn

This guide contains instructions on how to install the AT-FS20x and AT-FS202SC/FSx Series switches.

Where to Find Web-based Guides

The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support & Services” from our web site.

Document Conventions

This guide uses the following conventions:
Note
Notes provides additional information.
Caution
Cautions indicate that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
Warnings indicates that performing or omitting a specific action may result in bodily injury.
vii
Welcome to Allied Telesyn

Contacting Allied Telesyn

This section provides Allied Telesyn contact information for technical support as well as sales or corporate information.

Online Support

You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: www.alliedtelesyn.com/kb. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.

Email and Telephone Support

For Technical Support via email or telephone, refer to the Support & Services section of the Allied Telesyn web site: www.alliedtelesyn.com.

For Sales or Corporate Information

You can contact Allied Telesyn for sales or corporate information at our web site: www.alliedtelesyn.com. To find the contact information for your country, select Contact Us then Worldwide Contacts.
viii

Chapter 1

Description

The AT-FS20x and AT-FS202SC/FSx Series Switches include the following models:
AT-FS201 AT-FS202SC/FS2
AT-FS202 AT-FS202SC/FS3
AT-FS202SC/FS1 AT-FS202SC/FS4
The AT-FS20x Series switches are designed to extend the distance of your network by converting Fast Ethernet data between twisted-pair cabling and either multimode or single-mode fiber optic cabling. These dual-port switches can also be used to improve the performance of your network by dividing it into smaller, more manageable segments.
Each switch features a 100Base-FX fiber optic port and a 10Base-T/ 100Base-TX twisted-pair port. The fiber optic port has either a SC or ST connector and a maximum operating distance of 2 kilometers (1.2 miles) to 100 kilometers (62 miles), depending on the model. The twisted-pair port has an RJ-45 connector with a maximum operating distance of 100 meters (328 feet).
The fiber optic port operates at 100 Mbps, while the twisted-pair port operates at 10 Mbps or 100 Mbps. Both ports feature half- and full-duplex operation.
All of the AT-FS20x Series switches can be installed on a desktop or in an AT-MCR12 chassis. These switches are easy to install and do not require software configuration or management. This guide provides installation instructions for installing the AT-FS20x Series Switches on a desktop. To install the switches in an AT-MCR12 chassis, see AT-MCR12 Chassis Installation Guide (PN 613-10725-00).
1
Description
Figure 1 illustrates the front panel of an AT-FS20x Series switch.
100Base-FX
LNK/
ACT
FD/ COL
PORT 1
TX RX
10Base-T/
100Base-TX
CLASS 1
LASER PRODUCT
PORT 2
LNK/ ACT
FD/
COL
AT-FS202 FAST ETHERNET SWITCH IEEE 802.3/ 802.3U
Figure 1 AT-FS20x Series Front Panel (AT-FS202 Model)
Figure 2 illustrates a front panel of an AT-FS202SC/FSx Series switch.
100Base-FX
LNK/
ACT
FD/ COL
PORT 1
SINGLE MODE
TX RX
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
10Base-T/
100Base-TX
PORT 2
LNK/ ACT
FD/
COL
AT-FS202SC/FS4 FAST ETHERNET SWITCH IEEE 802.3/ 802.3U
Figure 2 AT-FS202SC/FSx Series Front Panel (AT-FS202SC/FS4 Model)
The back panel of the AT-FS20x and AT-FS202SC/FSx Series switches features a power adapter connector and DIP switches for manually configuring the ports.
Figure 3 illustrates the back panel.
DIP Switches
PWR
AUTO NEG
100M
PWR
AUTO NEG
100M
PORT
1222
21 34
DUPLEX
12 V DC
SPEED (Mbps)
10 100
MODE
HALF FULL
AUTO
NEG
OFF ON
DC Receptacle
Figure 3 Back Panel of the AT-FS20x and AT-FS202SC/FSx Series Switches
2
AT-FS20x Series Installation Guide
Table 1 lists the maximum operating distances for the switches.
Table 1 Maximum Operating Distances
100Base-FX 10/100Base-TX
Model
Connector
Maximum Operating Distance
Maximum
1
Connector
Operating Distance
2
AT-FS201 ST 2 km (1.2 mi) RJ-45 100 m (328 ft)
AT-FS202 SC 2 km (1.2 mi) RJ-45 100 m (328 ft)
AT-
SC 15 km (9.3 mi) RJ-45 100 m (328 ft) FS202SC/ FS1
AT­FS202SC/
SC 40 km (24.8
mi)
RJ-45 100 m (328 ft)
FS2
AT­FS202SC/
SC 75 km (46.5
mi)
RJ-45 100 m (328 ft)
FS3
AT-
SC 100 km (62 mi) RJ-45 100 m (328 ft) FS202SC/ FS4
1. Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating optical wavelength.
2. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to TIA/EIA 568A Commercial Building Telecommunications Cabling Standard.
3
Description

Key Features

The AT-FS20x switches have the following features:
LEDs for unit and port status
Auto MDI/MDI-X
DIP switches for configuring the ports
Half- or full-duplex operation on both ports
RJ-45 twisted-pair connector
SC or ST fiber optic connector
Data packet forwarding and filtering at full wire speed (10 Mbps to
100 Mbps, 100 Mbps to 100 Mbps, and 10 Mbps to 10 Mbps)
Store and forward switching mode
Automatic address learning and aging
IEEE 802.3u compliant Auto-Negotiation
External AC/DC power adapters (North America, Continental Europe,
or United Kingdom)
For use on a desktop or in an AT-MCR12 chassis

Status LEDs

Table 2 defines the LEDs for the switches.
Table 2 Status LEDs
LED Color Description
PWR Green Power is applied to the switch.
LNK/ACT Green
Blinking
4
A valid link has been established on the port.
Data is being received or transmitted on the port.
LED Color Description
AT-FS20x Series Installation Guide
100M Green
OFF
FD/COL Green
OFF
Blinking
AUTO NEG
Green
OFF
The twisted-pair port is operating at 100 Mbps.
The twisted-pair port is operating at 10 Mbps.
The switch is operating in full-duplex mode.
The switch is operating in half-duplex mode.
A collision has been detected on the port.
Auto-Negotiation on the twisted-pair port is enabled.
Auto-Negotiation on the twisted-pair port is disabled.

Twisted-Pair Port

The AT-FS20x and AT-FS202SC/FSx Series switches have one 10Base-T/ 100Base-TX twisted-pair port. The twisted-pair port features an RJ-45 connector.

Port Speed

The twisted-pair port is compliant with the 10Base-T and 10Base-TX standards and is capable of either 10 Mbps or 100 Mbps operation. You can set the port speed manually or, since the port is IEEE 802.3u Auto-Negotiation compliant, you can allow the switch to set the port speed automatically. With Auto-Negotiation, the speed of the port is set automatically by the switch after it determines the speed of the end-node connected to the port. Auto­Negotiation ensures that the port on the switch and the end-node are operating at the same speed and that they are communicating at the highest possible common speed of the devices.

Duplex Mode

Duplex mode refers to the way an end-node sends and receives data on the network. An end-node can operate in either half- or full-duplex mode, depending on its capabilities. An end-node that is operating in half-duplex mode can either send data or receive data, but it cannot do both at the same time. An end-node that is operating in full-duplex mode can send and receive data simultaneously. The best network performance is achieved when an end­node can operate at full-duplex, since the end-node is able to send and receive data simultaneously.
5
Description
The twisted-pair port on the switch can operated in either half- or full-duplex mode. You can set the duplex mode manually or allow the switch to set it automatically through Auto-Negotiation. With Auto-Negotiation, if the end­node is capable of full-duplex mode, the twisted-pair port is set automatically to full-duplex mode. If the end-node is capable of half-duplex mode, the port is set automatically to half-duplex mode.

Auto MDI/MDI-X

An RJ-45 twisted-pair port on a 10 Mbps or 100 Mbps Ethernet network device can have one of two possible wiring configurations: MDI or MDI-X. The RJ-45 port on a PC, router, or bridge is typically wired as MDI, while the twisted-pair port on a switch or hub is usually MDI-X.
To connect two 10 Mbps or 100 Mbps network devices together that have dissimilar port wiring configurations, such as MDI to MDI-X, use a straight­through twisted-pair cable. To connect two network devices that have the same wiring configuration, such as MDI to MDI, use a crossover cable.
The AT-FS20x switches feature automatic MDI/MDI-X. The RJ-45 port automatically determines the configuration of the port on the device to which it is connected and then configures itself appropriately. For example, if a port on a switch is connected to a port on a bridge, which is typically wired as MDI, the port on the switch automatically configures itself as MDI-X. This feature allows you to use either crossover cables or straight-through cables when connecting a device to the twisted-pair port.

Fiber Optic Port

The AT-FS20x switches have one 100Base-FX fiber optic port. The fiber optic port features either an SC or ST connector.

Port Speed

The fiber optic port is compliant with the 100Base-FX standard and has a fixed operating speed of 100 Mbps. The end-node connected to the fiber optic port on the switch must also be able to operate at 100 Mbps.

Duplex Mode

The fiber optic port on the switch can operate in half- or full-duplex mode. You must set the duplex mode manually using the DIP switches on the back of the unit.
6
AT-FS20x Series Installation Guide

Switch Performance

The AT-FS20x switches have the following performance values:
148,800 pps for 100 Mbps and 14,880 pps for 10 Mbps for full wire
speed forwarding and filtering
200 Mbps maximum throughput in 100 Mbps, full-duplex mode
20 Mbps maximum throughput in 10 Mbps, full-duplex mode
Storage for up to 4,000 MAC addresses
280 kilo bytes (per port) packet buffer
Low latency 15.6 µs (64-byte packet, 100 Mbps full-duplex)

DIP Switches

The DIP switches are used to manually configure the operating characteristics of the ports. These characteristics include the port speed, duplex mode, and Auto-Negotiation.
On the 100Base-FX fiber optic port, you can manually set the duplex mode to either half- or full-duplex.
On the 10Base-T/100Base-TX twisted-pair port, you can manually set the speed of the port to either 10 Mbps or 100 Mbps, set the duplex mode to either half- or full-duplex and enable or disable Auto-Negotiation. Enabling Auto­Negotiation automatically sets the port’s speed and duplex mode.

MAC Address Table

Up to 4,000 MAC addresses can be stored in the switch’s MAC address table. After power-up, the switch’s self-learning feature learns new addresses in real-time. If the source address of an incoming packet is not found in the MAC address table, the switch updates the table with the new address.
The switch also has an automatic address aging feature that deletes a source address from the table if it has not received a frame from the end-node with that address within five minutes. This prevents the table from becoming filled with addresses of end-nodes that are no longer active.
The switch forwards all multicast, broadcast, and unicast packets when the MAC address table has exceeded its storage limit.
7
Description

Store and Forward

The AT-FS20x switches support store and forward switching at Fast Ethernet full-wire speed in 100 Mbps, half- or full-duplex mode. Packets entering each port are stored in buffers. Once the packet is received, the switch forwards or discards the packet, depending on its destination address and error status. This ensures that only error-free packets destined for another segment are transferred across the switch, reducing the network load. For example, if the packet entering from Port 1 is destined for an end-node on Port 2, the switch forwards the frame as long as the frame does not contain any errors. If the packet from Port 1 is destined for an end-node also connected to Port 1, the packet is discarded.
The switch discards CRC errors, misaligned, runt, and under or oversized packets. When the packet has dribble bits at the end, the switch truncates to the octet boundary and checks for a good CRC before forwarding.

External AC/DC Power Adapter

The power adapter supplies 12V DC to the switch. Allied Telesyn supplies an approved safety compliant AC power adapter for the 100 and 240V AC versions with an unregulated output of 12V DC.

Network Topologies

This section provides an illustration of a typical network topology with an AT-FS202 Series switch.
8
AT-FS20x Series Installation Guide
Figure 4 illustrates a topology using one AT-FS202 switch to interconnect two small networks of stackable hubs.
AT-FS202
AT-FS708
AT-8026C
Twisted Pair
Fiber Optic
Figure 4 Typical Configuration Using the AT-FS202 Switch
170
9
Description
10

Chapter 2

Installing the Switch

This chapter explains how to install an AT-FS20x and AT-FS202SC/FSx Series switches. These switches can be installed on a desktop or in an AT-MCR12 chassis. The procedures provided in this chapter are for installation on a desktop. To install a switch in the AT-MCR12 chassis, see the AT-MCR12 Chassis Installation Guide.

Verifying Package Contents

Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
One AT-FS20x or AT-FS202SC/FSx Series switch
Four protective feet (for desktop use only)
External AC/DC power adapter (North America, Continental Europe,
or United Kingdom)
This installation guide
Warranty card
11
Installing the Switch

Planning the Installation

Be sure to observe the following guidelines when planning the installation of your switch.
The end-node connected to the 100Base-FX fiber optic port must be
able to operate at 100 Mbps.
The end-node connected to the 10Base-T/100Base-TX twisted-pair
port can operate at either 10 Mbps or 100 Mbps.
The end-node connected to a port on the switch can be a network
adapter card, repeater, router, hub, or another switch.
The twisted-pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband amplifiers, electrical motor, and fluorescent fixtures.
Refer to Table 3 for the cabling specifications for the twisted-pair port.
Table 3 10Base-T/100Base-TX twisted-pair Cabling Specifications
Operating Mode
10Base-T Shielded or unshielded Category 3 or
100Base-TX Shielded or unshielded Category 5 or
Cable Type
better
better
Maximum Operating Distance
100 m (328 ft)
100 m (328 ft)
Refer to Table 4 for the cabling specifications for the fiber optic port
operating in full-duplex mode.
Table 4 100Base-FX Fiber Optic Cabling Specifications (Full-duplex)
Model Cable Type
AT-FS201 50/125 or 62.5/
125 micron multimode
12
Maximum Operating Distance
2 km (1.2 mi) 13 dB at 1310 nm
1
Maximum Allowable Loss Budget
AT-FS20x Series Installation Guide
Model Cable Type
AT-FS202 50/125 or 62.5/
Maximum Operating Distance
1
2 km (1.2 mi) 13 dB at 1310 nm
Maximum Allowable Loss Budget
125 micron multimode
AT-FS202SC/FS1 50/125 or 62.5/
2 km (1.2 mi) 13 dB at 1310 nm
125 multimode
9/125 micron
15 km (9.3 mi) 16 dB at 1310 nm
single-mode
AT-FS202SC/FS2 9/125 micron
40 km (24.8 mi) 30 dB at 1310 nm
single-mode
AT-FS202SC/FS3 9/125 micron
75 km (46.5 mi) 33 dB at 1310 nm
single-mode
AT-FS202SC/FS429/125 micron
100 km (62 mi) 34 dB at 1550 nm
single-mode
1. Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating optical wavelength.
2. The cable must be non-dispersion-shifted, dispersion-shifted, or non-zero dispersion-shifted single-mode fiber optic cable.
Note
See “Fiber Optic Port Specifications” on page 22 for additional information on the fiber optic port.
13
Installing the Switch
Refer to Table 5 for the cabling specifications for the fiber optic port
operating in half-duplex mode.
Table 5 100Base-FX Fiber Optic Ports (Half-duplex)
Number of Switches Connected Devices
Maximum Operating Distance
1
One switch inline Switch to switch 372 m (1,221 ft)
Workstation to switch 372 m (1,221 ft)
Switch to Class I
137 m (450 ft)
repeater
Switch to Class II
185 m (607 ft)
repeater
Two switches Inline Switch to switch 332 m (1,089 ft)
Workstation to switch 322 m (1, 089 ft)
Switch to Class I
97 m (318 ft)
repeater
Switch to Class II
145 m (476 ft)
repeater
1. The total distance of the fiber optic lengths cannot exceed the limits stated in the table. Each switch used inline within a single collision domain reduces the overall segment length by 40 meters (131 feet).

Selecting a Site

Be sure to observe the following guidelines when selecting a site for your switch.
Select a site that is dust-free and moisture-free.
Select a site that allows you to easily access the data cables and power
cord.
Use dedicated power circuits or power conditioners to supply reliable
power to the device.
14
AT-FS20x Series Installation Guide

Installing the Switch

This section provides a procedure for installing the AT-FS20x switches. When setting the DIP switches consider the following:
Setting the Auto Neg DIP switch for the twisted-pair port to ON or
OFF enables or disables auto-negotiation for the port. If you disable auto-negotiation, be sure to set the DIP switches for the port’s speed and duplex mode to match the speed and duplex mode of the end-node.
For the fiber optic port, set the port’s duplex mode using the
appropriate Duplex Mode DIP switch. This setting must match the duplex mode capability of the end-node to be connected to the port.
Note
Do not remove the dust cover from the fiber optic port until you are ready to connect the fiber optic cable. Dust contamination can adversely impact the operating performance of the port and the switch.
To install an AT-FS20x switch on a desktop, perform the following procedure:
1. Remove all equipment from the package and store the packaging material
in a safe place. See “Verifying Package Contents” on page 11.
2. Attach the four protective feet (provided) to each corner of the bottom of
the unit.
3. Configure the DIP switches on the rear of the switch. See Table 6, “DIP
Switch Settings,” on page 15 for the settings.
Table 6 DIP Switch Settings
DIP Switch Number
1 2 Speed
2 1 Duplex
Port Setting Position Description
Up
(Mbps)
Down
Up
Mode
Down
The twisted-pair port is operating at 10 Mbps.
The twisted-pair port is operating at 100 Mbps.
The fiber optic port is operating at half-duplex mode.
The fiber optic is operating at full­duplex mode.
15
Installing the Switch
DIP Switch
Port Setting Position Description
Number
Table 6 DIP Switch Settings (Continued)
3 2 Duplex
Mode
Up
Down
The twisted-pair port is operating at half-duplex mode.
The twisted-pair port is operating at full-duplex mode.
4 2 Auto Neg Up
Auto-Negotiation on the twisted-pair port is OFF.
Down
Auto-Negotiation on the twisted-pair port is ON.
Caution
After you change the speed or duplex mode of the switch, you must power cycle (shut down and restart) the switch for the new settings to take affect.
4. Place the switch on a secure, level surface, leaving ample space around
the switch for ventilation.
5. Plug the AC/DC power adapter into an appropriate AC power outlet and
insert the power plug into the DC receptacle located on the back of the switch.
6. Verify that the PWR LED is green. If the LED is OFF, refer to
“Troubleshooting” on page 19 for instructions.
7. Remove the dust cover from the fiber optic port and connect the fiber optic
cable to the 100Base-FX port.
8. Connect the fiber optic cable to the 100Base-FX port on the end node.
9. Connect the twisted-pair cable (or cables) to the 10Base-T/100Base-TX
port.
16
AT-FS20x Series Installation Guide
10. Connect the twisted-pair cable (or cables) to the end node.
See Table 7 for information about setting the duplex mode. You must set the AT-FS20x switch and the end node to auto negotiate or make their port speeds match.
Table 7 Setting the Duplex Mode
FS20x Switch Duplex Mode
AUTO AUTO Link
AUTO 100 Mbps full-duplex
AUTO 100 Mbps half-duplex
100 Mbps full-duplex mode
100 Mbps full-duplex mode
100 Mbps half-duplex mode
11. Power ON the end-nodes.
12. Verify that the LNK/ACT LEDs for both the fiber optic port and the
twisted-pair port are green. If either LED is OFF, refer to “Troubleshooting” on page 19 for instructions.
End Node (Link Partner) Duplex Mode
mode
mode
100 Mbps full-duplex mode
AUTO No Link
AUTO No Link
Result
Link with a duplex mode mismatch
Link
Link
The switch is now ready for use.

Warranty Registration

When you have finished installing the product, register your product by completing the enclosed warranty card and sending it in. You can also fill out the registration online by selecting “Warranties” under “Support & Services” from www.alliedtelesyn.com.
17
Installing the Switch
18

Chapter 3

Troubleshooting

Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs.
Note
Whenever the speed and/or duplex mode are changed during or after power ON, power OFF then power back ON the switch to load the new configuration.
If the PWR LED is OFF, do the following:
If the switch is installed on a desktop, check that the power adapter is
securely connected to a power outlet. Also, check that the power adapter cable is securely connected to the back of the switch.
If the switch is installed in an AT-MCR12 chassis, check that the unit
is fully seated in the slot.
Verify that the power outlet has power by connecting another device
to it.
Try using another power adapter.
If the LNK/ACT LED for the twisted-pair port is OFF, do the following:
Check that the end-node connected to the port is powered ON and is
operating properly.
Check that the twisted-pair cable is securely connected to the twisted-
pair port on the switch and on the end-node.
Check that the end-nodes connected to the switch are operating in the
same duplex mode.
19
Troubleshooting
Make sure that the twisted-pair cable does not exceed 100 meters (328
feet) and that you are using a Category 3 or better cable for 10Base-T operation or a Category 5 or better cable for 100Base-TX operation. For information about maximum operating distances, see page 3.
If the LNK/ACT LED for the fiber optic port is OFF, do the following:
Table 1 on
Verify that the end-node connected to the port is ON and is operating
properly.
Check that the fiber optic cable is securely connected to the fiber optic
port on the switch and on the end-node.
Check that the end-node connected to the port is operating at 100
Mbps.
Check that the end-nodes connected to the switch are operating at the
same duplex mode.
Make sure that the cable connected to the switch’s receiver port (RX)
is connected to the end-node’s transmitter port (TX) and that the switch’s transmitter port (TX) is connected to the end-node’s receiver port (RX).
Test the attenuation on the fiber cable to ensure that it does not
exceed acceptable values.
Verify that you are using the appropriate type of fiber optic cables and
that you have not exceeded the maximum operating distances. For the maximum operating distances, refer to Table 1 on page 3 and for the cable types, refer to Table 3 on page 12, Table 4 on page 12, or Table 5 on page 14.
Check that the operating specifications of the fiber optic port on the
end-node are compatible with the operating specifications of the fiber optic port on the switch. For the fiber optic port specifications, refer to refer to Table 1 on page 3 and for the cable types, refer to Table 3 on page 12, Table 4 on page 12, or Table 5 on page 14.
If you are still experiencing problems after testing and troubleshooting the installation, contact Allied Telesyn Technical Support for assistance. Refer to “Contacting Allied Telesyn” on page viii.
20

Appendix A

Technical Specifications

Physical

Dimensions: W x D x H
10.5 cm x 9.5 cm x 2.5 cm (4.12 in x 3.75 in x 1.0 in)
Weight: 294 g (10.4 oz)

Temperature

Maximum Operating: 0° C to 40° C (32° F to 104° F)
Maximum Storage: -20° C to 80° C (-4° F to 176° F)
Relative Humidity: 5% to 95% non-condensing
Operating Altitude: Up to 3,048 meters (10,000 feet)

Electrical Rating

Input Supply Voltage: 12 V DC
Maximum Current: 500 mA
Power Consumption: 6 W
21
Technical Specifications

Agency Certifications

Safety Conforms to all standards normally supported
by Allied Telesyn products including safety standards UL 1950, CSA 22.2 No. 950, TUV EN60950, EN60825 CE Compliant
Standard CE Compliant IEEE 802.3, IEEE 802.3u
Immunity Conforms to EN55024 immunity standard
EMI/RFI Meets all applicable requirements for emissions
including but not limited to FCC Class A, IC Class A, EN55022 Class A

Fiber Optic Port Specifications

Tables 7 through 10 list the specifications for the fiber optic port.
Table 8 Fiber Optic Transmitter
Fiber Optic Diameter
Optical Wavelength
Model
Fiber Type
1
(microns)
AT-FS201 &
MMF 50/125 1310 nm -14.0 -20.3 -22.5
AT-FS202
MMF 62.5/125 1310 nm -14.0 -16.8 -19.0
AT-FS202SC/
SMF 9/125 1310 nm -8.0 -11.5 -15.0
FS1
AT-FS202SC/
SMF 9/125 1310 nm 0.0 -3.0 -5.0
FS2
AT-FS202SC/
SMF 9/125 1310 nm 0.0 -2.0 -4.0
FS3
AT-FS202SC/
SMF 9/125 1550 nm 0.0 -1.5 -3.0
FS4
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
2. The launch power is measured at one meter from the transmitter.
Launch Power (dBm)
Max. Avg. Min.
2
22
AT-FS20x Series Installation Guide
Table 9 Fiber Optic Receiver
Fiber Optic Diameter
Optical Wavelength
Model
Fiber Type
1
(microns)
AT-FS201 & AT-FS202
AT-
MMF 50/125 1310 nm -31.8 -34.5 -14.5
MMF 62.5/125 1310 nm -31.8 -34.5 -14.0
SMF 9/125 1310 nm -31.0 -31.0 -8.0 FS202SC/ FS1
AT-
SMF 9/125 1310 nm -35.0 -38.0 0.0 FS202SC/ FS2
AT-
SMF 9/125 1310 nm -37.0 -37.0 -3.0 FS202SC/ FS3
AT-
SMF 9.125 1550 nm -37.0 -37.0 -3.0 FS202SC/ FS4
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
Table 10 Fiber Optic Datalink
Receiver Sensitivity (dBm)
Min. Avg. Saturation
Model
AT-FS201 & AT-FS202
AT-FS202SC/ FS1
AT-FS202SC/ FS2
Fiber
1
Type
50/125 MMF
62.5/ 125 MMF
9/125 SMF
9/125 SMF
Minimum Power/ Link Budget
Average Signal Loss (dB)
Minimum Distance
2
Specs.
Maximum Distance Specs.
13.00 dB 18.70 dB 0 2 km (1.25 mi)
16.80 dB 22.50 dB 0 2 km (1.25 mi)
16.00 dB 19.50 dB 0 15 km (9.4 mi)
30.00 dB 35.00 dB 0 40 km (25 mi)
23
Technical Specifications
Minimum
Model
Fiber Type
1
Power/ Link Budget
AT-FS202SC/ FS3
AT-FS202SC/ FS4
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
2. The recommended minimum range is stated in all cases where the maximum transmitter output power exceeds the receivers saturation level. This is to prevent blinding or burning out of the optical receiver on the far-end node.
9/125 SMF
9/125 SMF
33.00 dB 35.00 dB 15 km (9.4
34.0 35.5 dB 40 km
Average Signal Loss (dB)
Minimum Distance Specs.
mi)
(24.8 mi)
Maximum Distance
2
Specs.
75 km (46 mi)
100 km (62 mi)
Table 11 Fiber Optic Loss Specification (Benchmark)
Fiber Type
1
Fiber Optic Diameter
MMF 50/125
microns
62.5/125 microns
Optical Wavelen gth
Typical Loss Factor
1310 nm 1.00 dB/
km
1310 nm 1.00 dB/
km
Worst Case Loss Factor
1.50 dB/ km
1.50 dB/ km
Bandwidth
400 Mhz­km
500 Mhz­km
SMF 9/125
microns
SMF 9/125 1550 nm 0.30 dB/
1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
1310 nm 0.40 dB/
km
km
1.00 dB/ km
0.75 dB/ km

Pinout Assignments

Figure 5 shows the pin assignments of the RJ-45 connector.
8
1
Figure 5 RJ-45 Pin Assignments
24
8
1
Not applicable
Not applicable
AT-FS20x Series Installation Guide
Table 12 lists the 10Base-T/100Base-TX connector pins and their signals when the port is operating in either MDI or MDI-X configuration.
Table 12 RJ-45 Pinouts
MDI-X (Default) Signal MDI Signal
1 RX+ 1 TX+
2 RX- 2 TX-
3 TX+ 3 RX+
4 - 4 -
5 - 5 -
6 TX- 6 RX-
7 - 7 -
8 - 8 -
25
Technical Specifications
26

Appendix B

Translated Safety and Emission Information

Important: This appendix contains multiple-language translations for the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av säkerhetsmeddelandena i denna handledning.
27
Translated Safety and Emission Information
Standards: This product meets the following standards.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
1RFI Emission EN55022 Class A2 Warning: In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
3 Immunity EN55024  4 Warning: This product requires shielded cables to comply with emission
and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
5 Electrical Safety EN60950, UL1950, CSA 950  6 Laser EN60825  7 Warning Class 1 Laser product.  8 Warning Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture.
9 This is a “Class 1 LED Product” (AT-FS201, AT-FS202, AT-FS203 models)
Safety
10 Lightning Danger
Danger: Do not work on equipment or cables during periods of lightning
activity.
11 Do not block air vents.  12 Power to the hub must be sourced only from the adapter.
28
AT-FS20x Series Installation Guide
USA/Canada
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
Europe - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA.
13 Operating Temperature: This product is designed for a maximum
ambient temperature of 40 degrees C.
14 All Countries: Install product in accordance with local and National
Electrical Codes.
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
1 Hochfrequenzstörung EN55022 Klasse A2 Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
3 Störsicherheit EN55024  4 Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit
den Richtlinien für Emission und Interferenzschutz entsprochen wird. Falls das Produkt mit nicht abgeschirmten Kabeln verwendet wird, können weitergehende Maßnahmen für die Korrektur von Interferenzproblemen auf Kosten des Benutzers notwendig werden.
5 Elektrische Sicherheit EN60950, UL1950, CSA 950  6 Laser EN60825  7 Warnung Laserprodukt der Klasse 1.  8 Warnung Nicht direkt in den Strahl blicken.  9 Das ist ein “LED Produkt der Klasse 1”
Sicherheit
10 Gefahr Durch Blitzschla
Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines
Gewitters ausführen
11 Entlüftungsöffnungen nicht versperren.  12 Der Buchse darf nur aus dem Adapter Strom zugeführt werden.
Europe - EU
Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für Gleichstrom 12 V, 500 mA.
13 Betriebstemperatur
Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen.
14 Alle Länder: Installation muß örtlichen und nationalen elektrischen
Vorschriften entsprechen.
29
Translated Safety and Emission Information
Standarder: Dette produkt tilfredsstiller de følgende standarder.
1Radiofrekvens
forstyrrelsesemission EN55022 Klasse A
2 Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio
forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
3 Immunitet EN55024  4Advarsel: Dette produkt skal bruges med afskærmede kabler for at
overholde bestemmelserne vedrørende udstråling og støjimmunitet. Hvis det bruges med uafskærmede kabler, kan det blive påkrævet af brugeren at korrigere interferensproblemer for egen regning.
5 Elektrisk sikkerhed. EN60950, UL1950, CSA 950  6 Laser EN60825  7Advarsel Laserprodukt av klasse 1.8Advarsel Stirr ikke på strålen.9 Dette er et “Produkt under Klasse 1 LED”
Sikkerhed
10 Fare Under Uvejr
Fare: Undlad at arbejde på udstyr eller kabler i perioder med lynaktivitet.
11 Ventilationsåbningerne må ikke blokeres.  12 Strømforsyningen til apparatet må udelukkende tages fra
tilpasningstransformatoren.
Europe - EU
Brug kun TÜV godkendt vekselstrømstransformator på 12 V jævnstrøm, 500 mA.
13 Betjeningstemperatur
Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C.
14 Alle Lande: Installation af produktet skal ske i overensstemmelse med
lokal og national lovgivning for elektriske installationer.
Eisen: Dit product voldoet aan de volgende eisen.
1RFI Emissie EN55022 Klasse A2 Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in
welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
3 Immuniteit EN55024  4 Waarschuwing: Om te voldoen aan de emissie- en immuniteitsnormen
dient dit apparaat te zijn voorzien van afgeschermde kabels. Als het met niet-afgeschermde kabels wordt gebruikt, kan het zijn dat de gebruiker maatregelen moet treffen om interferentieproblemen voor eigen rekening op te lossen.
5 Electrische Veiligheid EN60950, UL1950, CSA 9506 Laser EN60825
30
AT-FS20x Series Installation Guide
7 Waarshuwing Klasse-1 laser produkt.  8 Waarchuwing Neit in de straal staren.  9 Dit is een “Klasse 1 LED-produkt”
Veiligheid
10 Gevaar Voor Blikseminslag
Gevaar: Niet aan toestellen of kabels werken bij bliksem.
11 Ventilatiegaten niet blokkeren.  12 Stroom mag alleen via de adapter naar het apparaat toegevoerd worden.
Europe - EU
Gebruik een door TÜV gekeurde wisselstroomadapter van 12 Volt gelijkstroom, 500 milliampères.
13 Bedrijfstemperatuur
De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.
14 Alle Landen: het toestel installeren overeenkomstig de lokale en nationale
elektrische voorschriften.
Normes: Ce produit est conforme aux normes de suivantes.
1 Emission d'interférences
radioélectriques EN55022 Classe A
2 Mise En Garde: Dans un environnement domestique, ce produit peut
provoquer des interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
3 Immunité EN55024  4Avertissement : Il faut utiliser des câbles blindés pour ce produit afin de
respecter les normes d’émission et d’immunité. Si l’utilisateur choisit d’utiliser des câbles non blindés, il sera peut-être contraint de prendre les mesures nécessaires pour corriger les problèmes d’interférences, ainsi que d’assumer le coût correspondant.
5 Sécurité électrique EN60950, UL1950, CSA 950  6 Laser EN60825  7 Attention Producit laser di classe 1.  8 Attention Ne pas fixer le faisceau des yeux.  9 Ce mat‚riel est un “Produit a diode lectroluminescente de Classe 1”
Sécurité
10 Danger De Foudre
Danger: Ne pas manier le matériel ou les câbles lors d'activité orageuse.
11 Ne pas bloquer les fentes d'aération.  12 L'alimentation du concentrateur doit être uniquement fournie par
l'adaptateur.
Europe - EU
Utiliser un adaptateur secteur conforme TÜV de 12 V, 500 mA en courant continu.
31
Translated Safety and Emission Information
13 Température De Fonctionnement
Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés Celsius.
14 Pour Tous Pays: Installer le matériel conformément aux normes
électriques nationales et locales.
Standardit: Tämä tuote on seuraavien standardien mukainen.
1 Radioaaltojen häirintä EN55022 Luokka A  2 Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä,
missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
3 Kestävyys EN55024  4 Varoitus: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja
häiriönsietostandardien mukaisesti. Jos tuotetta käytetään ilman suojattuja kaapeleita, käyttäjä voi joutua korjaamaan häirinnän aiheuttaman ongelman omalla kustannuksellaan.
5 Sähköturvallisuus EN60950, UL1950, CSA 9506 Laser EN60825  7 Varoitus Luokan 1 Lasertuote.  8Variotus Älä katso säteeseen.9 Tämä on “Ensimmäisen luokan valodiodituote”
Turvallisuus
10 Salamaniskuvaara
Engenvaara: Älä työskentele laitteiden tai kaapeleiden kanssa
salamoinnin aikana.
11 Älä tuki ilmareikiä.  12 Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan
sovittimesta.
Europe - EU
Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat DC 12 V, 500 mA (milliampeeria).
13 Käyttölämpötila
Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C.
14 Kaikki Maat: Asenna tuote paikallisten ja kansallisten
sähköturvallisuusmääräysten mukaisesti.
32
AT-FS20x Series Installation Guide
Standard: Questo prodotto è conforme ai seguenti standard.
1 Emissione RFI (interferenza di
radiofrequenza) EN55022 Classe A
2 Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio
interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
3 Immunità EN55024  4Avvertenza: questo prodotto, se utilizzato con cavi schermati, è conforme
alle norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
5 Sicurezza elettrica EN60950, UL1950, CSA 950  6 Laser EN60825  7Avvertenza Prodotto laser di Classe 1.8Avertenza Non fissare il raggio con gli occhi.9 Questo è un “Prodotto con LED di Classe 1”
Norme Di Sicurezza
10 Pericolo Di Fulmini
Pericolo: Non lavorare sul dispositivo o sui cavi durante precipitazioni
temporalesche.
11 Non ostruire le prese d'aria.  12 Questo dispositivo deve essere alimentato solo mediante l’adattatore.
Europe - EU
Utilizzare l’adattatore per c.a. da 12 V c.c. e 500 mA conforme alla normativa TÜV.
13 Temperatura Di Funzionamento
Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi.
14 Tutti I Paesi: installare il prodotto in conformità delle vigenti normative
elettriche nazionali.
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
1 RFI stråling EN55022 Klasse A  2 Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet
forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
3 Immunitet EN55024  4Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille
emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning.
5 Elektrisk sikkerhet EN60950, UL1950, CSA 950
33
Translated Safety and Emission Information
6 Laser EN60825  7Advarsel Laserprodukt av klasse 1.8Advarsal Stirr ikke på strålen.9 Dette er et “Klasse 1 LED produkt”
Sikkerhet
10 Fare For Lynnedslag
Fare: Arbeid ikke på utstyr eller kabler i tordenvær.
11 Blokker Ikke Luftventilene  12 All strømtilførsel må komme fra adapteren.
Europe - EU
Benytt TÜV-godkjent AC-adapter på 12V DC, 500mA (millismpere)
13 Driftstemperatur
Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius.
14 Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale
elektriske koder.
Padrões: Este produto atende aos seguintes padrões.
1 Emissão De Interferência De
Radiofrequência EN55022 Classe A
2 Aviso: Num ambiente doméstico este produto pode causar interferência na
radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
3Imunidade EN550244Advertência: Este produto requer a utilização de cabos blindados para
cumprimento dos standards de limites de emissão e imunidade. Se o produto for utilizado com cabos não blindados, o utilizador poderá necessitar de tomar medidas para correcção de problemas de interferência, por sua própria conta.
5 Segurança Eléctrica TUV-EN60950, UL1950, CSA 950  6 Laser EN60825  7Aviso Produto laser de classe 1.8Aviso Não olhe fixamente para o raio.9 Este é um “Produto Classe 1 LED”
Segurança
10 Perigo De Choque Causado Por Raio
Perigo: Não trabalhe no equipamento ou nos cabos durante períodos
suscetíveis a quedas de raio.
11 Não Bloqueie As Aberturas De Ventilação  12 Use somente o adaptador fornecido para alimentação elétrica do hub.
Europe - EU
Use um adaptador de corrente alternada com saída DC de 12V e 500mA em conformidade com as especificações da TÜV.
34
AT-FS20x Series Installation Guide
13 Temperatura De Funcionamento
Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados.
14 Todos Os Países: Instale o produto de acordo com as normas nacionais e
locais para instalações elétricas. Estándares: Este producto cumple con los siguientes estándares.
1Emisión RFI EN55022 Clase A2 Advertencia: en un entorno doméstico, este producto puede causar
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
3 Inmunidad EN55024  4Advertencia: Este producto exige cables protectores para ajustarse a las
normas de emisión e inmunidad. Si se utiliza con cables sin protección, el usuario tendrá que correr con los gastos por las medidas a tomar en caso de problemas de interferencias.
5 Seguridad eléctrica TUV-EN60950, UL1950, CSA 950  6 Laser EN60825  7 ¡Advertencia! Producto láser Clase 1.  8 ¡Advertencia! No mirat fijamente el haz.  9 Este es un “Producto de diodo luminiscente (LED) Clase 1”
Seguridad
10 Peligro De Rayos
Eligro: No realice ningun tipo de trabajo o conexion en los equipos o en los
cables durante tormentas electricas.
11 No bloquee las aberturas para ventilacion.  12 La energía para el dispositivo central o "hub" debe provenir únicamente del
adaptador.
Europe - EU
Utilizar un adaptador de corriente alterna autorizado TÜV de 12 voltios de corriente continua y 500 miliamperios.
13 Temperatura Requerida Para La Operación
Este producto está diseñado para una temperatura ambiental máxima de 40 grados C.
14 Para Todos Los Países: Monte el producto de acuerdo con los Códigos
Eléctricos locales y nacionales.
Standarder: Denna produkt uppfyller följande standarder.
1Radiostörning EN55022 Klass A2 Varning: Denna produkt kan ge upphov till radiostörningar i hemmet,
vilket kan tvinga användaren till att vidtaga erforderliga åtgärder.
3 Immunitet EN55024  4 Varning! Denna produkt kräver skärmade kablar för att uppfylla
standardkraven för emission och immunitet. Om den används med oskärmade kablar kan användaren vara tvungen att vidta åtgärder på egen bekostnad för att åtgärda störningsproblemet.
35
Translated Safety and Emission Information
5Elsäkerhet TUV-EN60950, UL1950, CSA 9506 Laser EN60825  7 Varning! Laserprodukt av klass 1.  8 Varning! Laserstrålning när enheten är öppen.  9 Detta är en “Klass 1 lysdiodprodukt”
Säkerhet
10 Fara För Blixtnedslag
Fara: Arbeta ej på utrustningen eller kablarna vid åskväder.
11 Blockera Inte Luftventilerna.  12 Endast anslutningsenheten får vara kraftkälla till centralen.
Europe - EU
Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 12V, 500mA.
13 Driftstemperatur
Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius.
14 Alla Länder: Installera produkten i enlighet med lokala och statliga
bestämmelser för elektrisk utrustning.
36