Hydac OLF Compact Retrofitting Instructions

Page 1
OLF COMPACT
Umbauanleitung
Dichtungswechsel an der Pumpe
Deutsch: Seite 1-32
Retrofitting Instructions
Seal exchange on pump
English: Page 33-63
Doc.: 3226669-01c
Page 2
Inhaltsverzeichnis
1 Grundlegende Sicherheitshinweise...........................................................................................3
1.1 Verpflichtungen und Haftungen.............................................................................................3
1.2 Symbole und Hinweiserklärung.............................................................................................3
1.2.1 Grundlegende Symbole..................................................................................................4
1.3 Bestimmungsgemäße Verwendung ......................................................................................4
1.4 Sachwidrige Verwendung......................................................................................................4
1.5 Schutzeinrichtungen..............................................................................................................4
1.6 Informelle Sicherheitsmaßnahmen........................................................................................5
1.7 Verhalten im Notfall ...............................................................................................................5
1.8 Ausbildung des Personals.....................................................................................................5
1.9 Sicherheitsmaßnahmen im Normalbetrieb ............................................................................6
1.10 Gefahren durch elektrische Energie ..................................................................................6
1.11 Wartung und Instandhaltung, Störungsbeseitigung...........................................................6
1.12 Bauliche Veränderung an dem OLF ..................................................................................6
1.13 Spezielle Gefahren am Offline Filter OLF Compact...........................................................7
2 Lieferumfang .............................................................................................................................7
3 Erforderliches Werkzeug * ........................................................................................................8
4 Wechseln des Elektromotors ....................................................................................................9
4.1 Pumpenbaugruppe demontieren .........................................................................................12
4.1.1 Wellendichtring Demontage / Montage ........................................................................14
4.1.2 O-Ring Demontage / Montage .....................................................................................20
4.2 Montage der Pumpenbaugruppe.........................................................................................25
5 Inbetriebnahme .......................................................................................................................27
6 Fehler und Fehlerbeseitigung .................................................................................................28
7 Technische Daten ...................................................................................................................29
7.1 Abmessungen......................................................................................................................30
7.2 Aufbau Offline Filter.............................................................................................................31
8 Ersatzteile und Zubehör..........................................................................................................32
9 Entsorgung / Recycling und Außerbetriebnahme ...................................................................32
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 2
Page 3
1 Grundlegende Sicherheitshinweise
Diese Umbauanleitung enthält die wichtigsten Hinweise, um den Offline Filter OLF sicherheitsgerecht zu betreiben.
1.1 Verpflichtungen und Haftungen
Grundvoraussetzung für den sicherheitsgerechten Umgang und störungsfreien Betrieb
des OLF ist die Kenntnis der grundlegenden Sicherheitshinweise und der Sicherheitsvorschriften.
Diese Bedienungsanleitung, insbesondere die Sicherheitshinweise, sind von allen
Personen zu beachten, die mit dem OLF arbeiten.
Darüber hinaus sind die für den Einsatzort geltenden Regeln und Vorschriften zur
Unfallverhütung zu beachten.
Die hierin beschriebenen Sicherheitshinweise beschränken sich lediglich auf die
Verwendung des OLF.
Der OLF ist nach dem Stand der Technik und den anerkannten sicherheitstechnischen Regeln gebaut. Dennoch können bei der Verwendung Gefahren für Leib und Leben des Benutzers oder Dritter bzw. Beeinträchtigungen am Gerät oder an anderen Sachwerten entstehen. Der OLF ist nur zu benutzen
für die bestimmungsgemäße Verwendung
in sicherheitstechnisch einwandfreiem Zustand
Störungen, die die Sicherheit beeinträchtigen können, sind umgehend zu beseitigen.
Grundsätzlich gelten unsere Allgemeinen Geschäftsbedingungen (AGB). Diese stehen dem Betreiber spätestens seit Vertragsabschluß zur Verfügung. Gewährleistungs- und Haftungsansprüche bei Personen- und Sachschäden sind ausgeschlossen, wenn sie auf eine oder mehrere der folgenden Ursachen zurückzuführen sind:
Nicht bestimmungsgemäße Verwendung des OLF
Unsachgemäßes Montieren, Inbetriebnehmen, Bedienen und Warten des OLF
Betreiben des OLF bei defekten Sicherheitseinrichtungen
Eigenmächtige bauliche Veränderung am OLF
Mangelhafte Überwachung von Geräteteilen, die einem Verschleiß unterliegen
Unsachgemäß durchgeführte Reparaturen
1.2 Symbole und Hinweiserklärung
In dieser Bedienungsanleitung werden folgende Benennungen und Zeichen für Gefährdungen und Hinweise verwendet:
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 3
Page 4
1.2.1 Grundlegende Symbole
Dieses Symbol kennzeichnet Sicherheitshinweise, die bei Nichtbeachtung Gefährdungen für Personen hervorrufen können.
Dieses Symbol kennzeichnet Sicherheitshinweise, die bei Nichtbeachtung zu Gefährdungen von Personen durch elektrische Spannungen führen können.
Dieses Symbol gibt wichtige Hinweise für den sachgerechten Umgang mit dem OLF
Das Nichtbeachten dieser Hinweise kann zu Sachschäden an dem OLF oder zu Umweltschäden in deren Umgebung führen.
Unter diesem Symbol erhalten Sie Anwendungstips und besonders nützliche Informationen. Sie helfen Ihnen, alle Funktionen an Ihrem OLF optimal zu nutzen.
1.3 Bestimmungsgemäße Verwendung
Die Offline Filter der OLF-Compact Reihe wurden insbesondere für Anwendungen an Hydrauliksystemen mit einem Tankvolumen bis ca. 2000l entwickelt.
Alle anderen Verwendung gelten als nicht bestimmungsgemäß, für hieraus entstehende Schäden haftet der Hersteller nicht.
Zur bestimmungsgemäßen Verwendung gehören auch:
Das Beachten aller Hinweise aus der Bedienungsanleitung.
Die Einhaltung der Inspektions- und Wartungsarbeiten.
1.4 Sachwidrige Verwendung
Andere Verwendungen als oben aufgeführt sind verboten. Bei sachwidrigem Gebrauch können Gefahren entstehen. Solche sachwidrigen Verwendungen sind z.B. :
Falsches anschließen des Ein- bzw. Auslasses.
1.5 Schutzeinrichtungen
Vor jeder Inbetriebnahme des OLF müssen alle Schutzeinrichtungen an der Hydraulikanlage, an der der OLF zum Einsatz kommt, sachgerecht angebracht und voll funktionsfähig sein.
Schutzvorrichtungen dürfen nur entfernt werden nach Stillstand und Absicherung gegen Wieder-Ingangsetzen der Maschine (z.B. Warnschild oder Vorhängeschloß am Hauptschalter).
Bei Lieferung von Teilkomponenten sind die Schutzvorrichtungen durch den Betreiber vorschriftsmäßig anzubringen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 4
Page 5
1.6 Informelle Sicherheitsmaßnahmen
Die Bedienungsanleitung ist stets an dem OLF aufzubewahren. Ergänzend zur Bedienungsanleitung sind die allgemeingültigen sowie die örtlichen Regelung
zur Unfallverhütung und zum Umweltschutz bereitzustellen und zu beachten. Alle Sicherheits- und Gefahrenhinweise an dem OLF sind in lesbarem Zustand zu halten und
gegebenenfalls zu erneuern. Vor dem Öffnen von Teilen des OLF muß das Anschlußkabel abgeklemmt werden. Tests bei
geöffnetem Gehäuse dürfen nur von ausgebildeten Elektrofachkräften durchgeführt werden. Dies gilt auch für Reparaturen bzw. für von uns genehmigten Modifikationen an elektrischen Anlagenteilen.
Die Dichtheit der Anschlußstücke muss täglich überprüft werden (Sichtkontrolle). Die elektrische Ausrüstung des OLF muss ebenfalls regelmäßig überprüft werden (monatliche Sichtkontrolle). Lose Verbindungen und beschädigte Kabel sind sofort auszutauschen.
Alle Flüssigkeiten, die unter Druck stehen, können Körper-verletzungen mit Todesfolge verursachen. Beachten Sie deshalb unbedingt alle Sicherheitsvorschriften die beim Arbeiten mit unter Druck stehenden Flüssigkeiten gelten!
1.7 Verhalten im Notfall
Im Notfall trennen Sie bitte unverzüglich den OLF vom elektrischen Netz.
1.8 Ausbildung des Personals
Nur geschultes und eingewiesenes Personal darf an dem OLF arbeiten. Legen Sie die Zuständigkeiten des Personals klar fest. Anzulernendes Personal darf nur unter Aufsicht einer erfahrenen Person an dem OLF
arbeiten.
Personen
Tätigkeit
Verpackung Transport
Inbetriebnahme
Betrieb
unterwiesene
Personen
X X X X
X X X X
Personen mit
technischer Ausbildung
X X X
Elektrofachkraft Vorgesetzter
mit ent-
sprechender
Kompetenz
Störungssuche
Störungs­beseitigug
mechanisch
Störungs­beseitigug
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
X X X
X X
X X
de
Seite 5
Page 6
Personen
Tätigkeit
elektrisch
Wartung
Instandsetzung
Außerbetrieb­nahme
Lagerung
unterwiesene
Personen
X X X X
X X X X
Personen mit
technischer Ausbildung
Elektrofachkraft Vorgesetzter
mit ent-
sprechender
Kompetenz
1.9 Sicherheitsmaßnahmen im Normalbetrieb
OLF nur betreiben, wenn alle Schutzeinrichtungen voll funktionsfähig sind. Mindestens einmal pro Tag das Produkt auf äußerlich erkennbare Schäden und
Funktionsfähigkeit der Sicherheitseinrichtungen überprüfen.
1.10 Gefahren durch elektrische Energie
X
Arbeiten an der elektrischen Versorgung nur von einer Elektrofachkraft ausführen lassen. Die elektrische Ausführung des Produktes regelmäßig überprüfen. Lose Verbindungen und
angeschmorte Kabel sofort beseitigen. Sind Arbeiten an spannungsführenden Teilen notwendig, ist eine zweite Person
hinzuzuziehen, die notfalls den Hauptschalter ausschalten kann.
1.11 Wartung und Instandhaltung, Störungsbeseitigung
Vorgeschriebene Wartungs- und Inspektionsarbeiten fristgemäß durchführen. Alle Betriebsmedien gegen unbeabsichtigte Inbetriebnahme absichern. Bei allen Wartungs-, Inspektions- und Reparaturarbeiten, den OLF spannungsfrei schalten
und die Gesamtanlage gegen unerwartetes Wiedereinschalten sichern. Gelöste Schraubverbindungen auf festen Sitz kontrollieren. Nach Beendigung der Wartungsarbeiten Sicherheitseinrichtungen auf Funktion überprüfen.
1.12 Bauliche Veränderung an dem OLF
Nehmen Sie ohne Genehmigung des Herstellers keine baulichen Veränderungen an dem OLF vor.
Alle Umbaumaßnahmen bedürfen einer schriftlichen Genehmigung der Firma HYDAC Filtertechnik GmbH
Maschinenteile in nicht einwandfreiem Zustand sofort austauschen. Nur original Ersatz- und Verschleißteile verwenden. Bei fremdbezogenen Teilen ist nicht
gewährleistet, dass sie beanspruchungs- und sicherheitsgerecht konstruiert und gefertigt sind.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 6
Page 7
1.13 Spezielle Gefahren am Offline Filter OLF Compact
Der Betreiber muß durch geeignete Maßnahmen (z.B. Entlüften) die Bildung von Luftpolstern in Behältern und System verhindern.
Die Reparatur, Wartung und Inbetriebnahme darf nur von Fachpersonal durchgeführt werden. Der OLF nur im abgekühltem Zustand berühren!
Die Vorgaben in der Betriebsanleitung der Gesamtmaschine oder Anlage sind einzuhalten.
Achtung Druckgerät: Bei allen Arbeiten am Druckgerät ist sicherzustellen, daß der betreffende Druckraum (Filtergehäuse) druckfrei ist.
2 Lieferumfang
Der Dichtsatz wird verpackt geliefert. Bitte prüfen Sie vor dem Umbau den Dichtsatz auf Vollständigkeit.
Zum Lieferumfang gehören:
Pos. Menge Bezeichnung
1 1 Wellendichtring
2 2 O-Ring
2
1
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 7
Page 8
3 Erforderliches Werkzeug *
Zum Austausch des Dichtsatzes ist folgendes Werkzeug erforderlich:
Pos. Menge Bezeichnung
1 1 Kreuzschlitzschraubendreher PH#2
2 1 Gabelschlüssel 7x8 mm
3 1 Gabelschlüssel 10x13 mm
4 1 Gabelschlüssel 22x24 mm
5 1 Innensechskantschlüssel 3 mm
6 1 Innensechskantschlüssel 5 mm
7 1 Auszieherwerkzeug
8 1 Hammer 500 gr.
9 1 Lineal 300 mm
10 1 Drehmomentschlüssel (1-10 Nm)
11 1 Einsatz Innensechskant 3 mm
12 1 Einsatz Innensechskant 5 mm
*) nicht im Lieferumfang enthalten / not supplied
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 8
Page 9
4 Wechseln des Elektromotors
Pos. Darstellung Beschreibung
Der OLF ist Abzuschalten und auf Spannungsfreiheit zu prüfen.
Hydraulikanlage ist drucklos zu machen. Die Absperrorgane in der Saug- und
Druckleitung schliessen. Die Anschlußverrohrung zum OLF ist zu
entfernen.
Der OLF ist über den Ölablaufstopfen unten am Filtertopf vollständig zu entleeren.
Ölablaufstopfen
Der Ein- und Austritt (G1) ist mit Kunststoff­Verschlussstopfen zu verschließen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 9
Page 10
Pos. Darstellung Beschreibung
Klemmenkasten am Elektromotor öffnen und die elektrische Zuleitung abklemmen und entfernen.
Den OLF am Einbauort demontieren. Dazu sind die am Elektromotorfuß
angebrachten 4 Befestigungsschrauben /­muttern zu lösen.
Spannklammer
Die Spannklammer öffnen und über den Filtertopf nach unten ablegen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 10
Page 11
Pos. Darstellung Beschreibung
Elektromotor mit montierter Pumpenbauguppe vom Filtertopf heben.
Das Filterelement verbleibt im Filtertopf.
Elektromotor mit Pumpenbaugruppe
Filterelement
Filtertopf
Lüfterhaube
Elektromotor auf der Lüfterhaube abstellen.
Auf saubere Unterlage achten !
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 11
Page 12
4.1 Pumpenbaugruppe demontieren
Die 4 Stück Zylinderschrauben mit Innenseckskant lösen (Gegenuhrzeigersinn) und diese in den Bohrungen belassen.
Der hierzu benötigte Innsechskantschraubendreher hat die Schlüsselweite SW = 5 mm.
b
[a]
Die Pumpenbaugruppe (Pumpe und Anschlussstück) [a] mit beiden Händen ausschließlich an der Pumpe [b] anpacken und langsam nach oben anheben.
[b]
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 12
Page 13
Pumpenbaugruppe auf ebener und sauberer Unterlage abstellen.
Anschlussstück von Pumpe abnehmen.
Anschlussstück
Pumpe
Anschlussstück
Pumpe
Anschlussstück von Pumpe abnehmen und ...
auf sauberer Unterlage ablegen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 13
Page 14
4.1.1 Wellendichtring Demontage / Montage
Ausziehwerkzeug*
Griffstück
Kappe mit Scheibe
Auszieher Hülse Montagedorn
*) nicht im Lieferumfang enthalten
Stift entnehmen und auf sauberer Unterlage ablegen
Stift
Steuersheibe
Pumpenkörper
Wellendichtring
Pumpe um 180° drehen und auf der Steuerscheibe ablegen, so dass der Wellendichtring nach oben zeigt
Auszieher zusammendrehen
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 14
Page 15
Auszieher durch den Wellendichtring einführen bis der Wulst des Ausziehers in den Wellendichtring greift
Auszieher
Wellendichtring
Wulst
Auszieher aufdrehen bis Widerstand spürbar ist.
Hülse überstülpen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 15
Page 16
Kappe zur Hülse auflegen. Dabei beachten,
Unterlagscheibe
Kappe
Hülse
dass die Unterlegscheibe nach oben zeigt.
Am Griffstück die Sechskantmutter bis zum oberen Gewindeende drehen.
Griffstück Sechskantmutter
Griffstück
Hülse
Griffstück im Uhrzeigersinn auf den Auszieher aufschrauben bis dieser vollständig aufgedreht ist.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 16
Page 17
Griffstück
Auszieher am Griffstück festhalten und die Sechskantmutter SW24 mit einem Gabelschlüssel im Uhrzeigersinn drehen bis der Wellendichtring vollständig aus der Pumpe gezogen ist.
Gabelschlüssel
Hülse
Ausziehwerkzeug vollständig abheben.
Auszieher aus Hülse nehmen.
Auszieher
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
Hülse
de
Seite 17
Page 18
Griffstück mittels Gabelschlüssel SW 13 vom Auszieher im Gegenuhrzeigersinn abschrauben.
Griffstück
Auszieher
Auszieher
1.
2.
Wellendichtring
1. Auszieher zusammenschrauben.
2. Wellendichtring vom Auszieher nehmen und entsorgen.
Wellennut auf Schmutz und Schäden kontrollieren gegebenenfalls reinigen / nacharbeiten.
Anschließend mit Medium benetzen.
Wellendichtring mit Medium benetzen.
Wellendichtring
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 18
Page 19
Montagedorn
Wellendichtring – offene Seite
Montage
Wellendichtring
Wellendichtring auf den Montagedorn aufstecken dabei auf korrekte Einbaulage achten.
Die offene Seite den Wellendichtringes in Richtung Pumpe montieren.
Montagedorn mit Wellendichtring in Hülse einführen.
Hülse Sleeve
Mit einem 500 gr. Hammer bestimmt auf die Einführhilfe schlagen bis der Wellendichtring vollständig in der Nut sitzt.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 19
Page 20
Die Einbaulage des Wellendichtringes mit einem Lineal prüfen. Dieser darf nicht über die Nut / Pumpe herrausragen.
4.1.2 O-Ring Demontage / Montage
Pumpe um 180° auf die Seite des Wellendichtringes ablegen.
O-Ring entnehmen und entsorgen.
3x Innensechkantschrauben mittels Innensechskantschlüsseln SW 3 im Gegenuhrzeigersinn zu lösen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 20
Page 21
1
Steuerscheibe nach oben abnehmen.
O-Ring entnehmen und entsorgen und Fläche mit sauberem Tuch abreiben.
Keine Reinigungsmittel verwenden.
Sichtprüfung auf Riefen an der Dichtfläche der Steuerscheibe.
Bei deutlich sichtbaren Riefen an
Innenflächen oder Teilen, ist die Reparatur abzubrechen und eine neue Pumpe zu verwenden.
Den neuen O-Ring und die Nut mit Medium benetzen.
O-Ring in Nut einlegen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 21
Page 22
Steuerscheibe auflegen dabei auf die korrekte Einbaulage (wie nachfolgend beschrieben) achten.
B
C
C
Steuerscheibe - Oberseite
C
A
B
B
A = Stiftloch B = Schraubloch C = Durchgangsbohrung
C
Stift zur Montagekontrolle einstecken. Steuerscheibe ausrichten, dass Durchgangslöcher sowie Gewindelöcher übereinstimmen. Dieses trifft nur in einer Position zu.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 22
Page 23
Der Stift darf max. x=5 mm über die Steuerscheibe herrausragen.
X
O-Ring und Nut mit Medium benetzen. O-Ring in die Nut einlegen.
3x Innensechkantschrauben mittels Innensechskantschlüssel SW 3 im Uhrzeigersinn festziehen (Drehmoment = 3 Nm).
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 23
Page 24
Mit einem Finger durch den Wellendichtring den Rotor der Pumpe auf Leichtgängigkeit prüfen. D.h. der Rotor muss sich ohne Kraftaufwand mit dem Finger drehen bzw. verschieben lassen.
Rotor so verschieben, dass die Passfedernut
!
freiliegt damit die Passfeder der Motorwelle eingreifen kann.
Anschlussstück auf Pumpe aufsetzten, dabei die Ausrichtung der Teile zueinander beachten.
Verschmutzungsanzeige
Anschlussstück
Pumpe
Pumpe mit dem Stift nach hinten und Anschlussstück mit der Verschmutzungsanzeige nach vorne legen.
Stift
Anschlussstück auf Pumpe setzen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 24
Page 25
4.2 Montage der Pumpenbaugruppe
Die Position der Paßfeder [k] an der Motorwelle auf die exakt gleich Position der Paßfedernut in der Pumpe drehen.
k
b
Pumpenbaugruppe exakt zentriert auf den Elektromotor aufsetzten.
Die 4 Stück Zylinderschrauben mit Innensechskant mittels Innensechskantschraubenschlüssel SW = 5 mm mit 9 Nm (im Uhrzeigersinn) festschrauben.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 25
Page 26
Elektromotor mit montierter Pumpenbaugruppe auf Filtertelement und Filtertopf aufsetzten.
Spannklammer montieren und spannen. (Anzugsmoment = 5 Nm (max. 10 Nm))
Verschlußstopfen im Ein- und Austritt entfernen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 26
Page 27
Die Anschlussrohre am Einbauort mit dem OLF verbinden.
Öffnen der Absperrorgane in den Leitungen.
Elektrische Verbindung gemäß Anschlußplan wieder herstellen.
Deckel des Klemmenkasten verschließen. Hydraulikanlage entlüften. OLF wieder in Betrieb nehmen.
5 Inbetriebnahme
Schließen Sie den OLF COMPACT an das elektrische Netz an und prüfen Sie mittels Tippbetrieb die Drehrichtung des Motors. Ein Markierungspfeil auf dem Gehäuse zeigt die richtige Drehrichtung an.
Sollte eine Änderung der Drehrichtung nötig sein, so vertauschen Sie bitte die Brücke gemäß Anschlußplan im Anschlußgehäuse des E-Motors.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 27
Page 28
6 Fehler und Fehlerbeseitigung
Fehler Ursache(n) Abhilfe
kein Ölfluß
Filter verschmutzt
Pumpe fördert in die falsche Richtung
Luft in Saugleitung und Pumpe Es kann einige Minuten dauern
Betriebsviskosität < 200mm²/s und ungefüllte Pumpe
Medium ist stark verschmutzt Ersetzen Sie das Filterelement
Vergewissern Sie sich, daß die Pumpe in Richtung des Markierungspfeils am Gehäuse fördert. Tauschen Sie ggf. zwei Brücken des elektr. Anschlusses.
bis die Pumpe die Luft abtransportiert hat, Vorteile bringt auch ein Drehen des OLF­Compact in die waagerechte Lage bis die Luft abgeführt ist.
Fördert die Pumpe auch nach ca. 5 min nicht, hilft ein Vorfüllen der Pumpe (über die Saugleitung) mit Fördermedium
In diesem Viskositätsbereich benötigt die Pumpe ca. 10 Minuten um den max. Volumenstrom zu erreichen. Siehe 6.D
(Verschmutzungs­anzeige spricht an)
Leckage am Filtertopf Ablaßschraube am Filtertopf
Filterelement ist erschöpft Ersetzen Sie das Filterelement
Die Viskosität des Mediums ist zu hoch
Warten Sie bis sich durch das Umpumpen des Öls in der Pumpe (Druckbegrenzungs­ventil geöffnet) eine Erwärmung des Öls eingestellt hat und normaler Pumpbetrieb aufgenommen wird.
bzw. die Spannklammer am Filtertopf nachziehen
(Anzugsdrehmoment der Spannklammer: 5 Nm (max. 10 Nm))
Bei Spin-on Elementen, Element festziehen bzw, Dichtung erneuern.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 28
Page 29
7 Technische Daten
Betriebsdruck 3,5 – 6 bar
Volumenstrom 4 l/min
Fluid Temperatur 0 – 80° C
Umgebungstemperatur -20 - +40° C
Verschmutzungsanzeige VM 2 BM
Dichtungsmaterial NBR / FPM
Schutzart IP 55
Gewicht
Stromversorgung 120 V AC, 50/60 Hz
Leistungsaufnahme 0,37 kW
Umdrehungen / min. 1800 bei 60 Hz
Umschaltung Kondensator Die Umschaltung des Anlauf- und
Filterelement Dimicron 5µm (siehe Ersatzteilliste)
Schmutzaufnahmekapazität 200 g
11 kg
Betriebskondensators erfolgt mittels Spannungsrelais.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 29
Page 30
7.1 Abmessungen
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 30
Page 31
7.2 Aufbau Offline Filter
Pos. Bezeichnung Pos. Bezeichnung
1.10 Anschlussstück 1.64 O-Ring
1.11 Verschlussschraube 1.70 Adapter
1.20 Verschmutzungsanzeige 2.20 Motor
1.30 Kegel 2.21 Buchse
1.31 Druckfeder 2.22 O-Ring
1.32 Führung 2.23 Passfeder
1.33 Sicherungsring 2.30 Flügelzellenpumpe, kpl.
1.40 O-Ring 2.31 Stift
1.41 O-Ring 2.32 Pumpenkörper
1.42 O-Ring 2.33 Flügel
1.43 Dichtring 2.34 Rotor
1.50 Innensechskantschraube 2.35 Innenring
1.60 Führung 2.36 O-Ring
1.61 Druckfeder 2.37 Steuerscheibe
1.62 Kegel 2.38 Innensechskantschraube
1.63 Ventilsitz 2.39 Wellendichtring
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 31
Page 32
8 Ersatzteile und Zubehör
Artikel-Nr. Artikelbezeichnung
3075882 Reparaturset Filtertopf FPM
Bestehend aus: 1x Filtertopf, 1x O-Ring, 1x Entleerungsschraube, 1x Spannklammer
3081959 Reparatursatz OLF 5/4 FPM
Bestehend aus: O-Ringe, Flügel, Wellendichtring, Befestigungsschrauben
3068101 Filterelement N5DM005, Filterfeinheit 5 µm
6026511 Motor Olf-5/4 120V/60Hz mit Anlauf- und Betriebskondensator
303191 Verschmutzungsanzeige
3075885 Reparatursatz Pumpe OLF-5/4 FPM
Bestehend aus: 1x Flügelzellenpumpe, 6x O-Ring, 4x Schraube
9 Entsorgung / Recycling und Außerbetriebnahme
Bei der Außerbetriebnahme und/oder Entsorgung des CS müssen alle lokalen Richtlinien und Auflagen bezüglich Arbeitssicherheit und des Schutzes der Umwelt berücksichtigt werden. Insbesondere gilt dies für das im Gerät befindliche Öl, ölverschmierte und elektronische Bauteile.
Nach erfolgter Demontage sortenreiner Trennung sind die Teile entsprechend den örtlichen Bestimmungen der Entsorgung bzw. dem Recycling zuzuführen.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c de.doc 2005-11-15
de
Seite 32
Page 33
Retrofitting Instructions OLF Compact
Contents
1 General Safety Precautions ............................................................................................ 34
1.1 Obligations and Liability............................................................................................... 34
1.2 Explanation of Symbols and Warnings, etc. ................................................................ 34
1.2.1 Basic Symbols...................................................................................................... 35
1.3 Proper/Designated Use ............................................................................................... 35
1.4 Improper Use............................................................................................................... 35
1.5 Safety Devices............................................................................................................. 35
1.6 Informal Safety Precautions ........................................................................................36
1.7 Instructions to Be Followed in the Event of an Emergency .........................................36
1.8 Training and Instruction of Personnel.......................................................................... 36
1.9 Electrical Hazards........................................................................................................ 37
1.10 Maintenance, Servicing and Troubleshooting.......................................................... 37
1.11 Modifications to the OLF ..........................................................................................38
1.12 Special Hazards Posed by the OLF......................................................................... 38
2 Scope of Delivery ............................................................................................................38
3 Required tools *...............................................................................................................39
4 Replacing the Electric Motor ........................................................................................... 40
4.1 Dismanteling pump unit ...............................................................................................43
4.1.1 Shaft seal dismounting / mounting ....................................................................... 45
4.1.2 O-Ring Removal / Replacement........................................................................... 51
4.2 Pump unit mounting..................................................................................................... 56
5 Recommissioning............................................................................................................ 58
6 Errors and Troubleshooting............................................................................................. 59
7 Technical Data ................................................................................................................ 60
7.1 Dimensions..................................................................................................................61
7.2 Vane pump .................................................................................................................. 62
8 Spare Parts ..................................................................................................................... 63
9 Disposal / Recycling and Decommissioning ...................................................................63
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 33
Page 34
Retrofitting Instructions OLF Compact
1 General Safety Precautions
These retrofitting instructions contain the key instructions for properly and safely operating the conversions kit.
1.1 Obligations and Liability
The basic prerequisite for the safe and proper handling and operation of the OLF is knowledge of the safety instructions and warnings.
These operating instructions in general, and the safety precautions in particular, are to be adhered by all those who work with the OLF.
Adherence is to be maintained to pertinent accident prevention regulations applicable at the site where the product is used.
The safety precautions listed herein are limited solely to using the OLF.
The OLF has been designed and constructed in accordance with the current state of the art and recognized safety regulations. Nevertheless, hazards may be posed to the life and limb of the individual using the product or to third parties. Risk of damage may be posed to the product or other equipment and property. The OLF is to be used as follows:
solely for its designated use
only when in a safe, perfect condition
Any faults or malfunctions which might impair safety are to be immediately properly
repaired or remedied.
Our General Terms and Conditions apply. They are made available to the owner upon concluding purchase of the product at the latest. Any and all warranty and liability claims for personal injuries and damage to property shall be excluded in the event they are attributable to one or more of the following causes:
improper use of the OLF or use deviating from its designated use,
improper assembly, installation, commissioning, operation and maintenance of the
OLF,
operating the OLF when the system equipment or systems are defective,
modifications to the product made by the user or purchaser,
improper monitoring of product components subject to wear and tear, or
improperly performed repair work
1.2 Explanation of Symbols and Warnings, etc.
The following designations and symbols are used in this manual to designate hazards, etc.:
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 34
Page 35
Retrofitting Instructions OLF Compact
1.2.1 Basic Symbols
This symbol identifies safety instructions that may lead to hazards to persons if not observed.
This symbol identifies safety instructions that may lead to personal injuries due to electric shocks if not observed.
This symbol provides important instructions and tips for the proper handling and operation of the OLF.
Non-adherence to these instructions may result in damage to the OLF or in damage to its immediate surroundings.
This symbol designates tips for usage and other particularly useful information.
This information helps you to optimally utilize all the features offered by your OLF.
1.3 Proper/Designated Use
The OLF Compact filter unit range was especially designed for hydraulic systems with reservoir volumes of approx. 2.000 litres.
Any other use shall be deemed to be improper and not in keeping with the product designated use. The manufacturer will not assume any liability for any damage resulting from such use.
Proper or designated use of the product extends to the following:
Maintaining adherence to all the instructions contained herein and.
Performing requisite inspection and maintenance work.
1.4 Improper Use
Any use deviating from the proper/designated use described above is prohibited.
Improper use may result in hazard to life and limb.
Example of improper use:
improper connection of the OLF inlet and outlet ports.
1.5 Safety Devices
Prior to starting up the product each time, make sure that all the safety devices are properly fitted to the hydraulic system in which the product is to be used and are in proper working order.
Safety devices may not be removed until the product has been shut down and secured against being restarted (e.g. warning sign or padlock on the main switch).
When the product is supplied in partial consignments, the safety devices are to be applied by the operator as specified by law/pertinent regulations.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 35
Page 36
Retrofitting Instructions OLF Compact
1.6 Informal Safety Precautions
Make sure to always keep the operating instructions in the vicinity of the product.
Apart from the operating instructions, any and all general and local regulations pertaining to accident prevention and environmental protection are to be made available and observance to be maintained to them.
Make sure to keep the safety and hazard symbols and warnings on the product in a legible condition.
The power plug/cord of the product is to always be pulled before opening any components of the product. Tests conducted with the housing open may only be performed by properly trained, certified electricians. This also applies to all repair work or to any modifications to electric components approved by us.
The hoses and connection fittings are to be checked daily for leakage (visual check). The electrical components of the product are to also be regularly checked (visual check once a month). Any loose connections or damaged cables are to be replaced immediately.
Warning: Pressurized fluids pose a hazard to life and limb.
Consequently, the safety regulations pertaining to working with pressurized liquids are to be adhered to at all time!
1.7 Instructions to Be Followed in the Event of an Emergency
In the event of an emergency, immediately disconnect the OLF from the power supply.
1.8 Training and Instruction of Personnel
The OLF may only be operated by properly trained and instructed personnel.
The areas of responsibility of your staff must be established in a clear-cut manner.
Staff undergoing training may not use the OLF unless supervised by an experienced staff member.
Individuals
Activity
Packing Transportation
Commissioning
Individuals
undergoing
training
X X X X
Individuals with
technical
training/ engineering background
X X X
Electrician Supervisor
with the
appropriate
authority
Operation
Troubleshooting/ locating the source of malfunction
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
X X X X
X X X
en
Page 36
Page 37
Retrofitting Instructions OLF Compact
Individuals
Activity
Remedying of mechanical faults
Remedying of electrical faults
Maintenance and servicing
Repair work
Shutdown/ decommissioning
Storage
Individuals
undergoing
training
X X X X
X X X X
1.9 Electrical Hazards
Individuals with
technical
training/ engineering background
X X
Electrician Supervisor
with the
appropriate
authority
X X
X
Any work involving the power supply may only be done by a properly trained, certified electrician.
Make sure to check the electrical equipment of the product on a regular basis. Any loose connections or damaged cables are to be remedied/replaced immediately.
If work to live components is required, a second individual is required who can switch off the product at the main switch as may prove necessary.
1.10 Maintenance, Servicing and Troubleshooting
The prescribed adjustment, maintenance/servicing and inspection work is to be conducted in a timely fashion.
All operating media is to be protected/isolated for the event that the product is accidentally started up.
The OLF is to be disconnected from the power supply and protected against being inadvertently switched back on when performing any maintenance, servicing, inspection or repair work.
Any screwed fittings which have been undone/removed are to be checked to see that they have been properly retightened / reinstalled.
Always check the product to see that it functions properly when performing maintenance and servicing.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 37
Page 38
Retrofitting Instructions OLF Compact
1.11 Modifications to the OLF
Do not make any modifications (design modifications, extensions) to the OLF without the prior consent of the manufacturer.
Any design modifications or extensions may not be made without HYDAC Filtertechnik GmbH express prior written approval.
Immediately replace any machine components which are not in perfect condition.
Only use original (OEM) spare parts and consumables. When using non-OEM components it cannot be ensured that they have been designed and manufactured so as to comply with loading and safety requirements.
1.12 Special Hazards Posed by the OLF
The owner/operator has to prevent the formation of air cushions in tanks and the system by taking suitable measures (e.g. air-bleeding).
Repair, maintenance, servicing and commissioning work may only be performed by properly trained personnel. Do not touch the enclosed reel filter unless it has completely cooled.
Make sure to adhere to the operating instructions of the overall unit or facility.
Caution when dealing with pressure vessels: In any work involving the pressure vessel make sure that the pressure chamber (filter housing) is unpressurized.
2 Scope of Delivery
The Seal Kit comes packed. Before start your work, check the contents of the package to make sure everything is present.
The Seal Kit comes with the following:
Pos. Qty. Description
1 1 Shaft seal
2 2 O-ring
1
2
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 38
Page 39
Retrofitting Instructions OLF Compact
3 Required tools *
The following tools will be required for replacing the seals:
Pos. Qty. Description
1 1 Screwdriver cross slot PH #2
2 1 Open-end wrench 7x8 mm
3 1 Open-end wrench 10x13 mm
4 1 Open-end wrench 22x24 mm
5 1 Allen key, 3 mm
6 1 Allen wrench, 5 mm
7 1 Puller
8 1 Hammer 500 gr.
9 1 Maschinist’s scale 300 mm
10 1 Torque wrench (1-10 N-m)
11 1 Allen bit for torque wrench, 3 mm
12 1 Allen bit for torque wrench, 5 mm
*) not supplied
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 39
Page 40
Retrofitting Instructions OLF Compact
4 Replacing the Electric Motor
Item Illustration Description
Switch off the OLF and disconnected it from the electrical.
The hydraulic / lubrication system must be depressurised.
Close all shut-off valves in suction and return lines.
Remove the connecting piping to the OLF.
Completely drain the OLF by opening the oil drain plug on the bottom of the contamination container (filter bowl).
Oil drain plug
Seal off the inlet (S) and outlet (P) ports with plastic sealing plugs.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 40
Page 41
Retrofitting Instructions OLF Compact
Item Illustration Description
Open the terminal box to the electric motor. Disconnect the electric lead and remove it.
Remove the OLF from the assembly.
To do this, undo the 4 mounting screw located at the base of the electric motor.
Clamp
Open the clamp and remove it by pulling it downwards over the filter bowl.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 41
Page 42
Retrofitting Instructions OLF Compact
Item Illustration Description
Lift up the electric motor with the mounted pump assembly off the filter bowl.
Leave the filter element in the filter bowl.
Electric motor with mounted pump assembly
Filter element
Filter bowl
Fan shroud
Set the electric motor down on the fan shroud.
Set the electrical motor down on a clean
surface, only !
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 42
Page 43
Retrofitting Instructions OLF Compact
4.1 Dismanteling pump unit
Undo the 4 Allen-head screws by unscrewing them counterclockwise direction). Leave the screws in their holes.
Use a 5-mm Allen key for this propose.
b
2.
[a]
Grasp the pump assembly [a] (pump, connector piece, adapter) using both hands, making sure to only grasp the pump [b], and slowly lift it up.
[b]
b
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 43
Page 44
Retrofitting Instructions OLF Compact
Set the pump assembly down on a clean flat surface.
Remove the adaptor from the pump.
Adaptor
Adaptor
Pump
Pump
Remove the adaptor from the pump and ...
... set it down on a clean surface.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 44
Page 45
Retrofitting Instructions OLF Compact
4.1.1 Shaft seal dismounting / mounting
Puller*
Grip
Puller Sleeve Mandrel
*) not supplied
Pin
Control disk
Pump body
Shaft seal
Cap with washer
Remove the retaining pin and set it down on a clean surface.
Rotate the pump through 180° and position it on the control disk such that the shaft seal is on top.
Close the puller’s jaws.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 45
Page 46
Retrofitting Instructions OLF Compact
Guide the puller through the shaft seal until ist lip engages the shaft seal.
Puller
Shaft seal
Lip
Open the puller’s jaws until a resistance is felt.
Slide the sleeve over the puller’s shaft.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 46
Page 47
Retrofitting Instructions OLF Compact
Set the cap on the sleeve, making certain that
Washer
Cap
Sleeve
the washer is on top.
Screw the nut on the grip all the way up to the end of the thread.
Grip
Hex nut
Screw the grip clockwise onto the puller until it reaches the end of the thread, i.e., the nut abuts against the cap.
Grip
Sleeve
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 47
Page 48
Retrofitting Instructions OLF Compact
Grip
Hold the puller’s grip steady and turn the 24­mm hex nut clockwise using an open-end wrench until the shaft seal is clear of the pump.
Open-end wrench
Sleeve
Puller
Withdraw the puller.
Withdraw the puller from the sleeve.
Sleeve
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 48
Page 49
Retrofitting Instructions OLF Compact
Unscrew the grip from the puller by turning it counterclockwise using a 13-mm open-end wrench.
PullerGrip
Puller
1.
2.
Shaft seal
1. Close the puller’s jaws.
2. Take the shaft seal off the puller and discard it
Check the groove on the shaft for contamination and wear and clean/rework it, if necessary.
Subsequently wet it with medium.
Wet the shaft seal with medium.
Shaft seal
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 49
Page 50
Retrofitting Instructions OLF Compact
Slide the shaft seal onto the mandrel, making
Mandrel
certain that it is correctly positioned.
The free end of the shaft seal should face the pump.
Free end of shaft seal
Insert the mandrel, along with the shaft seal, into the sleeve.
Mandrel
Shaft seal
Sleeve
Use a 500-gram hammer to drive the mandrel into the sleeve until the shaft seal is correctly seated in the groove.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 50
Page 51
Retrofitting Instructions OLF Compact
Check the seating of the shaft seal using a machinist's rule. The seal should not protrude beyond the top of the groove/top surface of the pump.
4.1.2 O-Ring Removal / Replacement
Turn the pump over, onto the side with the shaft seal.
Remove the O-ring and discard it.
Remove the 3 Allen-head screw by unscrewing them counterclockwise using a 3-mm Allen key.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 51
Page 52
Retrofitting Instructions OLF Compact
1
Lift off the control disk.
Remove the O-ring, discard it, and wipe its seat with a clean cloth.
Use no cleaning agents.
Visually inspect the sealing surface on the control disk for scoring.
If any scoring should be clearly visible on
its mating surface or other parts, the repair should be aborted and a new pump employed.
Wet the new O-ring and groove with medium.
Seat the O-ring in the groove.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 52
Page 53
Retrofitting Instructions OLF Compact
Set the control disk onto the pump body and verify that it is correctly positioned thereon (cf. above).
B
C
C
A
Control disk - top side
C
B
B
A = Hole for locating pin
B = Threaded holes for screws
C = Through holes
C
Insert the locating pin as a check for correct alignment. Align the control disk such that the through holes and threaded holes in the control disk are aligned on those in the pump body, which will be the case in one orientation only.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 53
Page 54
Retrofitting Instructions OLF Compact
The locating pin should nut protrude more than 5 mm from the control disk.
X
Wet the O-ring and groove with medium.
Seat the O-ring in the groove.
Insert the 3 Allen-head screws into the threaded holes on torque them down clockwise to 3 N-m using a torque wrench.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 54
Page 55
Retrofitting Instructions OLF Compact
Poke your finger through the shaft seal and verify that the pump’s rotor is free to rotate, i.e., you should be able to easily rotate its rotor and displace it longitudinally with your finger.
Displace the rotor such that the keyway is
!
Adaptor
exposed in order that the key on the motor is able to engage the keyway.
Set the adaptor on the pump, making certain that it is correctly aligned on the pump.
Turn the pump and adaptor such that locating pin is at the rear and the clogging indicator in the adaptor is facing you.
Clogging indicator
Pin
Pump
Set the adaptor onto the pump.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 55
Page 56
Retrofitting Instructions OLF Compact
4.2 Pump unit mounting
Rotate the motor shaft until the key [k] on the shaft is accuratly aligned on the keyway in the pump’s rotor.
k
b
Accurately center the pump assembly on the electric motor
Insert the 4 Allen-head screws and torque them down clockwise to 9 N-m using a 5-mm Allen wrench.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 56
Page 57
Retrofitting Instructions OLF Compact
Set the electric motor, together with the assembled pump assembly, onto the filter element and filter bowl.
Install the clamp and tighten it down.
(Torque spec. = 5 N-m (max. 10 N-m))
Remove the sealing plugs from the inlet and outlet ports.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 57
Page 58
Retrofitting Instructions OLF Compact
Connect the connecting piping to/from the system to the OLF.
Restore the electric connection as shown in the terminal diagram below.
Replace the cover of the terminal box and tighten down its fastening screws.
Bleed the air out of the hydraulic system.
Recommissioning the OLF.
5 Recommissioning
Start up the OLF COMPACT.
Next, check the motor’s direction of rotation. To do this, briefly interrupt the electrical supply (jogging skip). An arrow on the adaptor indicates the correct direction of rotation which is clockwise, looking toward the blower. If the direction of rotation should be wrong, two bridges circuits in the control box will have to be rewired.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 58
Page 59
Retrofitting Instructions OLF Compact
6 Errors and Troubleshooting
Error Cause(s) Remedy
No oil flow
Filter contaminated
(Clogging indicator has switched)
Pump is pumping fluid in the wrong direction.
Air in the induction tract and pump It might take some minutes until the
Operating viscosity <200mm²/s and pump not primed
Medium heavily contaminated Replace filter element
Filter element service life exceeded
Fluid viscosity too high Wait until the oil has been warmed up
check rotation of the pump - if necessary change the electrical connection
Two bridge circuit in the control box have to be changed
pump has transported the air away, and pumps the fluid. The turning of the OLF-Compact in a horizontal position for some minutes will help.
If the unit does not pump yet the me­dium after approx. 5 min, please fill the pump via the inlet side.
Operating condition in which the max. flow rate is only achieved after approx. 10 minutes. Cf. 6.D.
Replace filter element
by pumping within the pump
Leakage at the filter housing
(pressure relief valve opened). After the fluid has been warmed up the pump starts operation.
Check, if the draining screw or the clamp on the filter housing is tightened. (Tightening torque for clamp: 5 N-m (max. 10 N-m))
For Spin-on model units, check if the element is tightened, or change seal.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 59
Page 60
Retrofitting Instructions OLF Compact
7 Technical Data
Operating Pressure 3.5 – 6 bar
Flow rate 4 l/min
Fluid temperature 0 – 80° C
Ambient temperature -20 - +40° C
Clogging Indicator VM 2 BM
Seal materials NBR / FPM
Safety class IP 55
Weight
Voltage 120 V AC, 50/60 Hz
Electrical Power consumption 0.37 kW
Revolutions per min. 1800 by 60 Hz
Capacitor switching Start- and operation capacitor is switching with relay.
Filter element Dimicron 5 µm (see Spare Parts list)
Contamination capacity to ISO 4572
11 kg
200 g
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 60
Page 61
Retrofitting Instructions OLF Compact
7.1 Dimensions
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 61
Page 62
Retrofitting Instructions OLF Compact
7.2 Vane pump
Item Description Item Description
1.10 Adaptor 1.64 O-ring
1.11 Screw plug 1.70 Adaptor
1.20 Clogging indicator 2.20 E-Motor
1.30 Cone 2.21 Bushing
1.31 Compression spring 2.22 O-ring
1.32 Guide 2.23 Parallel key
1.33 Circlip 2.30 Vane pump, complete.
1.40 O-ring 2.31 Pin
1.41 O-ring 2.32 Pump body
1.42 O-ring 2.33 Vane
1.43 Seal 2.34 Rotor
1.50 Allen-head screw 2.35 Inner ring
1.60 Guide 2.36 O-ring
1.61 Compression spring 2.37 Control disk
1.62 cone 2.38 Allen-head screw
1.63 Valve seat 2.39 Shaft seal
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 62
Page 63
Retrofitting Instructions OLF Compact
8 Spare Parts
P/No. Description
3075882 Repair kit Filter housing FPM
Content:
1x Filter pot, 1x O-Ring, 1x Oil draining screw, 1x Clamp
3081959 Repair kit Olf-5/4 FPM
Content:
O-ring seals, vanes, shaft seal, Screws
3068101 Filter element N5DM005 – 5 µm
6026511 Motor Olf-5/4 120V/60Hz complete with starting and running capacitors
303191 Clogging indicator BM
3075885 Repair kit pump complete OLF-5/4-FPM
Content:
1x Vane pump, 6x O-rings, 4x Screws
9 Disposal / Recycling and Decommissioning
When decommissioning and/or disposing of the OLF, adherence is to be maintained to local occupational-safety and environmental-protection guidelines and regulations, particularly when disposing of hydraulic fluid contained in the unit, components covered with hydraulic fluid, and electronic components.
After disassembling the unit and separating the various materials, they can be reused or disposed of properly in accordance with local regulations.
HYDAC Filtertechnik GmbH
UA OLFC 3226669-01c en.doc 2005-11-15
en
Page 63
Loading...