All rights reserved. No part of this work may be reproduced in any form (print,
photocopy or by other means) or processed, duplicated or distributed using
electronic systems without the written consent of the publisher.
These documents have been created and inspected with the greatest care.
However, errors cannot be ruled out completely.
All details are subject to technical modifications. Technical specifications are
subject to change without noti ce .
Index ............................................................................................................ 78
OLFCM 15/30/45/60
en(us)
5 / 84
Preface
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
HYDAC FILTER SYSTEMS GMBH
Technische Dokum ent ati on
Pos tfach 12 51
66273 S ulzbach / Saar
Preface
We have compiled the most important instructions for the operation and
maintenance of our product for you, its user, in this docu me nt ation.
It will acquaint you with the product and assist you in using it as intended in
an optimal manner.
Keep this documentation in the v i ci ni ty of the produc t for i mm ediate
reference.
Sometimes the information contained in the documentation cannot always
keep up with changes made to the product as we attach considerable
importance to keeping our products cutting-edge.Consequently, there might
be deviations in technical details, illustrations and dimensions.
If you discover errors while reading the documentation or have suggestions
or other useful information, please don’t hesitate to contact us:
Germany
OLFCM 15/30/45/60
en(us)
6 / 84
Preface
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Fax:
+49 (0) 6897 509 - 846
E-Mail:
filtersystems@hydac.com
Technical Support
Contact our technical sales department if you have any questions on our
product. When contacting us, always include the model/type designation,
serial no. and part-no. of the product:
Product modification
We would like to point out that changes to the product (e.g. purchasing
additional options, etc.) may mean that the information in the operating
instructions is no longer applicable or adequate.
After modification or repair work that affects the safety of the product has
been carried out on components, the product may not be returned to
operation until it has been checked and released by a HYDAC technician.
Report any modifications carried out on the product by you or a third party
immediately.
Warranty
For the warranty provided by us, please refer to the General Terms of Sale
and Delivery of HYDAC FILTER SYST EMS GMBH.
You will find these under www.hydac.com -> General terms and con di ti ons .
OLFCM 15/30/45/60
en(us)
7 / 84
Preface
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Note that the method described for locating specific information
these instructions prior to starting the unit up for the first time and
Chapter description
Page number
Document language
Documentation no.
Using the documentation
does not release you from your responsibility of carefully reading
at regular intervals in the future.
What do I want to know?
I determine which topic I am looking for.
WHERE can I find the information I’m looking for?
The documentation has a table of contents at the beginning. There, I select
the chapter I'm looking for and the corresponding page number.
Edition date
with index/
file name
The documentation number with its index enables you to order another copy
of the operating and maintenance instructions.
The index is incremented every time the manual is revised or changed.
OLFCM 15/30/45/60
en(us)
8 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Safety informati on
The unit was built according to the statutory provisions valid at the time of
delivery and satisfies current safety requirements.
Any residual hazards are indicated by safety information and instructions and
are described in the operating instructions.
Observe all safety and warning instructions attached to the unit. They must
always be complete and legible.
Do not operate the unit unless all the safety devices are present.
Secure the hazardous areas which may arise between the unit and other
equipment.
Maintain the unit inspection intervals prescribed by law.
Document the results in an inspection certificate and keep it until the next
inspection.
Hazard symbols
These symbols are listed for all safety information and instructions in these
operating instructions which indicate particular hazards to persons, property
or the environment.
Observe these instructions and act with particular caution in such cases.
Pass all safety information and instructions on to other users.
General hazard
Danger due to electrical voltage / current
Exposed electrical co mp on en ts
Danger of electrical shock
OLFCM 15/30/45/60
Danger due to operating pressure
en(us)
9 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
DANGER
DANGER – The signal word indicates a hazardous situation with a high level
WARNING
WARNING – The signal word indicates a hazardous situation with a medium
CAUTION
CAUTION – The signal word indicates a hazardous situation with a low level
NOTICE
NOTICE – The signal word indicates a hazardous situation with a high level
Warning of flammable substances
Signal words and their meaning in the safety information and
instructions
In these instructions you will find the following signal words:
of risk, which, if not avoided, will result lethal or serious injury.
level of risk, which, if not avoided, can result lethal or serious injury.
of risk, which, if not avoided, can result in minor or moderate injury.
of risk, which, if not avoided, will result in damage to property.
OLFCM 15/30/45/60
en(us)
10 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Structure of the safety information and instructions
All warning instructions in this manual are highlighted with pictograms and
signal words. The pictogram and the signal word indicate the severity of the
danger.
Warning instructions listed before an activity are laid out as follows :
HAZARD SYMBOL
SIGNAL WORD
Observe regulatory information
Observe the following regulatory information and guidelines:
• Legal and local regulations for accident prevention
• Legal and local regulat ions for environmental protectio n
• Country-specific regul a t ions , or g ani zation-specific regulations
Type and source of danger
Consequence of the danger
►Measures to avert danger
OLFCM 15/30/45/60
en(us)
11 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Proper/Designated Use
Use the unit only for the application described in the following.
The OLF Compact is a stationary filter unit used for filtering hydraulic or
lubricating oils in bypass flow.
Proper or designated us e of the prod uc t extends to the following :
• observing all instructions contained in the instruction manual.
• performing inspectio n and maintenance work.
Depending on the version (see model code), you may use the OLF only in
connection with the following media:
WARNING
Fire hazard
Danger of bodily injury
► With the OLF, you may filter/pump only
media/fluids with a flash point ≥ 56°C/133°F
NOTICE
Unpermitted operating media
The filtration unit will be destroyed.
►The OLF is to be used only with mineral oils or mineral oil-based
raffinates.
►Do not filter any caustic or explosive media.
OLFCM 15/30/45/60
en(us)
12 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Never operate the unit in potentially explosive
Improper Use or Use Deviating from Intended Use
DANGER
Danger due to unanticipated use of the unit
Bodily injury and damage to property will result
when operated improperly.
►
atmospheres.
►The unit is only to be used with permissible
media.
Any use extending beyond or deviating therefrom shall not be considered
intended use. HYDAC Filter Systems GmbH will assume no liability for any
damage resulting from such use. The user alone, shall assume any and all
associated risk
Improper use may result in hazards and/or will damage the unit. Examples of
improper use:
• Operation in potentially explosive atmospheres.
• Operation with a non-approved medium.
• Operation under non-approved operational conditions.
• Operation when the safety devices are defective.
• Modifications to the power unit made by the user or purchaser.
• Inadequate monitoring of parts that are subject to wear and tear
• Improperly performed repair work.
OLFCM 15/30/45/60
en(us)
13 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Qualifications of personnel / target group
Persons who work on the power unit must be aware of the associated
hazards when using the power unit.
Auxiliary and specialist personnel must have read and understood the
operating instructions, in particular the safety information and instructions,
and applicable regulations before beginning work.
The operating instructions and applicable regulations are to kept so they are
accessible for operating and specialist personnel.
These operating instructions is intended for:
Auxiliary personnel: such persons have been instructed in power unit
operation and are aware of pote nti al haz ar ds due to i mproper use.
Specialist personnel : such persons with corresponding specialist training and
several years work experience. They are able to assess and perfor m the
work assigned to them, they are also able to recognize potential hazards.
OLFCM 15/30/45/60
en(us)
14 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Activity
Personnel
Knowledge
Transport / storage
Forwarding agent
Proof of knowledge of
Hydraulic / electrical
Specialist personnel
Safe handling/use of
Operation,
Auxiliary personnel
Product-specific
Disposal
Specialist personnel
Proper and
installation,
first commissioning,
operation/settings
maintenance,
troubleshooting,
repair,
decommissioning,
disassembly
Specialist personnel
cargo securing
instructions
Safe handling/operat ion
of hoisting and lifting
equipment
tools
Fitting and connection
of hydraulic lines and
connections
Fitting and connection
of electrical lines,
electrical machinery,
sockets, etc.
Checking the phase
sequence
Product-specific
knowledge
Operations control
knowledge
Knowledge about how
to handle operating
media
environmentally-friendly
disposal of materials
and substances
Decontamination of
contaminants
Knowledge about reuse
OLFCM 15/30/45/60
en(us)
15 / 84
Safety information
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Wear suitable clothing
Loose-fitting clothing increases the risk of being caught or being drawn in on
rotating parts, and the risk of getting caught on protruding parts. You can be
severely injured or killed.
• Wear close-fitting clothing.
• Do not wear any rings, chains or any other jewelry.
• Wear work safety shoes.
Stoppage in an emergency (EMERGENCY STOP)
In case of emergency, switch off the power unit at the main switch.
OLFCM 15/30/45/60
en(us)
16 / 84
Transporting the OLF
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Transport the OLF in an upright
For transportation using a crane or
Transporting the OLF
position only.
forklift, use two slings at the
specified anchor points between
the filter housing and the base.
OLFCM 15/30/45/60
en(us)
17 / 84
Storing the OLF
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Storage temperature:
5 … 30°C / 41 … 86°F
Humidity:
up to 80% relative humidity, non-condensing
Air condition:
Clean, salt-free air, not near oxidizing substances
Storage duration:
Indefinite.
Store the OLF in an upright
Storing the OLF
Completely drain the OLF and remove all filter elements before putting into
storage.
position only.
(rust film).
Before the unit is started up again after being
stored for more than two years, all seals must be
replaced.
OLFCM 15/30/45/60
en(us)
18 / 84
Checking the scope of delivery
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Item
Qty.
Description
1 1 OffLine Filter 15/30/45/60
Operation and Maintenance Instructions OLFCM 15-60
- 1 Operating and maintenance instructions CS1000
- 1 Operating and maintenance instructions AS 1000 (optional)
- 1 Operating and maintenance instructions SMU1200 (optional)
Checking the scope of delivery
Upon receiving the OLF, check it for any damage in transit. Do not put the
OLF into operation unless it is in perfect condition. Any damage in transit is to
be reported to the forwarding agent or the department in charge immediately;
the unit may not be commissioned until this damage is properly remedied.
The following items are suppl ied:
- 1
(this document)
OLFCM 15/30/45/60
en(us)
19 / 84
OLF Features
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Differential pressur e at 15l/min.
Viscosity [mm²/s]
OLF Features
The filters of the OLF 15/30/45/60 series are sturdy filters for stationary
applications in hydraulic and lubrication systems with large volumes of fluid.
Features of the DIMICRON® filter elements used in thes e filter s ar e thei r
particularly high contamination retention capacity and an environmentally
safe method of disposal (incinerable).
The OLFCM has a vane pump and is suitable for operating fluids with a
viscosity of 15–200 mm²/s.
Pressure drop over DIMICRON® filter element(s)
Differential pressur e [bar]
The pressure loss through the filter housing is negligible.
OLFCM 15/30/45/60
en(us)
20 / 84
OLFCM components
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
OLFCM components
OLFCM 15/30/45/60
en(us)
21 / 84
OLFCM components
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Item
Description
1
Inlet (IN)
2
Outlet (OUT)
3
Motor pump assembly
4
Protective screen
5
ContaminationSensor CS1000
6
AquaSensor AS1000 (optional)
8
Air bleed
9
Back-pressure indicator
10
Draining
11
Filter housing
12
Differential pressur e indicator (optional)
20
Switch cabinet (optional)
21
SensorMonitoring Unit (opt ional)
OLFCM 15/30/45/60
en(us)
22 / 84
Dimensions
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Dimensions
The filtration unit is available in different versions; below you will find an
overview with the corresponding dimensions.
Version OLF 15/15, 30/15
(All dimensions in mm)
OLFCM 15/30/45/60
en(us)
23 / 84
Dimensions
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Version – OLF 30-60
(All dimensions in mm)
OLFCM 15/30/45/60
en(us)
24 / 84
Dimensions
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Version – OLF30-60 - FA
(All dimensions in mm)
OLFCM 15/30/45/60
en(us)
25 / 84
Hydraulic diagram
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
M
CS
OUT
IN
AS
3
4
5
6
7
8
12
11
10
9
1
2
Hydraulic diagram
OLFCM 15/30/45/60
en(us)
26 / 84
Loading...
+ 58 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.