All rights reserved. This manual may not be reproduced in part or whole without the
express written consent of HYDAC FILTER SYSTEMS GMBH. Contraventions are
liable to compensation.
Exclusion of Liability
Wir haben unser Möglichstes getan, die Richtigkeit des Inhalts dieses Dokuments
zu gewährleisten, dennoch können Fehler nicht ausgeschlossen werden.
Consequently, we accept no liability for such errors as may exist nor for any damage
or loss whatsoever which may arise as a result of such errors. The content of the
manual is checked regularly. Any corrections required will be incorporated in future
editions. We welcome any suggestions for improvements.
All details are subject to technical modifications.
Technical specifications are subject to change without notice.
HYDAC FILTER SYSTEMS GMBH
Postfach 12 51
66273 Sulzbach / Saa
Germany
Documentation Representative
Mr. Günter Harge
c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar
For you, as the owner of a product manufactured by us, we have produced this
manual, comprising the most important instructions for its operation and
maintenance.
It will acquaint you with the product and assist you in using it as intended in an
optimal manner.
Keep it in the vicinity of the product so it is always available.
Note that the information on the unit's engineering contained in the documentation
was that available at the time of publication.There may be deviations in technical
details, figures, and dimensions as a result.
If you discover errors while reading the documentation or have additional comments
or suggestions, contact us at:
HYDAC FILTER SYSTEMS GMBH
Technische Dokumentation
Postfach 12 51
Contact our technical sales department if you have any questions on our product.
When contacting us, please always include the model/type designation, serial no.
and part-no. of the product:
Fax: ++49 (0) 6897 / 509 – 846
E-mail: filtersystems@hydac.com
Modifications to the Product
We would like to point out that changes to the product (e.g. purchasing additional
options, etc.) may mean that the information in the operating instructions is no
longer applicable or adequate.
After modification or repair work that affects the safety of the product has been
carried out on components, the product may not be returned to operation until it has
been checked and released by a HYDAC technician.
Please notify us immediately of any modifications made to the product whether by
you or a third party.
Warranty
For the warranty provided by us, please refer to the General Terms of Sale and
Delivery of HYDAC Filter Systems GmbH.
Refer to these at www.hydac.com General terms and conditions.
Note that the method described for locating specific information does
not release you from your responsibility of carefully reading these
instructions prior to starting the unit up for the first time and at regular
intervals in the future.
What do I want to know?
I determine which topic I am looking for.
Where can I find the information I’m looking for?
The documentation has a table of contents at the beginning. There, I select
the chapter I'm looking for and the corresponding page number.
Chapter description
Page number
Edition date
Documentation no.
with index/
file name
Document language
The documentation number with its index enables you to order another copy of the
operating an
d maintenance instructions. The index is incremented every time the
These operating instructions contain the most important information for operating
the OF in a proper, safe manner.
Obligations and Liability
The basic prerequisite for the safe and proper handling and operation of the unit is
knowledge of the basic safety instructions and safety regulations.
These operating instructions in general, and the safety instructions in particular, are
to be adhered by all those who work with the unit.
Adherence is to be maintained to pertinent accident prevention regulations
applicable at the site where the product is used.
The safety instructions listed here are restricted to use of the unit.
The OF has been designed and constructed in accordance with the current state of
the art and recognized safety regulations. Nevertheless, hazards may be posed to
the life and limb of the individual using the product or to third parties. Risk of
damage may be posed to the product or other equipment and property.
Ensure that the unit is used:
solely for its designated use
only when in a safe, perfect condition
Immediately remedy any malfunctions that might impair safety.
Our General Terms and Conditions apply. They are made available to the owner
upon concluding purchase of the unit at the latest. Any and all warranty and liability
claims for personal injuries and damage to property shall be excluded in the event
they are attributable to one or more of the following causes:
improper use of the unit or use deviating from its designated use
improper assembly/installation, start up, operation and maintenance of the unit
operating the OF when the system equipment or systems are defective
modifications made by the user or purchaser
Improper monitoring of unit components that are subject to wear and tear
Any use deviating from the proper/designated use described above is prohibited.
Improper use may result in hazard to life and limb.
Example of improper use:
Commissioning without a suction strainer
Operation with non-approved fluids
Informal Safety Precautions
Make sure to always keep the operating instructions in the vicinity of the unit.
Apart from the operating instructions, any and all general and local regulations
pertaining to accident prevention and environmental protection are to be made
available and observance is to be maintained to them.
Make sure to keep the safety and hazard symbols and warnings on the product in a
legible condition.
Structural modifications to the unit
Do not make any modifications (design modifications, extensions) to the OF without
the approval of the manufacturer.
Immediately replace any unit components which are not in perfect condition.
Only use original (OEM) spare parts and consumables. When using non-OEM
components it cannot be ensured that they have been designed and manufactured
so as to comply with loading and safety requirements.
The OF may only be operated by properly trained and instructed personnel. The
areas of responsibility of your staff must be established in a clear-cut manner.
Staff undergoing training may not use the OF unless supervised by an experienced
staff member.
s w
ua
v
undergoing training
n
technical training/
engineering
background
Electrician
Supervisor with the
appropriate authority
Activity
Individuals
Individuals
Packing / transportation
Commissioning
Operation
Troubleshooting/
locating the source of malfunction
The filtration unit is supplied ready for connection and immediate operation with
hoses and a mains connection.
Check the unit for damage upon delivery. A unit may only be put into operation if it
shows no signs of damage. Report any damage in transit to the forwarding agent or
responsible party.
The following items are supplied:
Item Qty. Description
1 1 OF5 with power cable, suction hose and pressure hose
The filtration unit OF 5 mobile is designed for the filling of hydraulic tanks, whilst
simultaneously filtering the fluid. It also provides offline filtration and can be used for
draining hydraulic tanks as well as for pumping out hydraulic and lubrication oils
without filtration.
Items supplied
NOTICE
Impermissible operating media
The unit will be damaged
► The unit is only to be used with mineral oils or mineral oil-based raffinates.
Consult and observe the following chapter in order to prepare the OF5 for operation.
Inserting the filter element
The unit has no filter element installed upon delivery from the factory. Prior to start
up, check to see whether a filter element is contained in the filter housing.
Information on changing a filter element can be found on page 26.
Hanging / connecting the suction hose
NOTICE
Severe contamination
The unit will be destroyed
► Do not prime directly at the bottom of the tank (in the sump).
The greatest contamination is found on the bottom of the tank. All
impurities and other particles are deposited on the bottom of the tank.
Pull the suction hose (thick hose) with lance out of the mounting in the floor plate.
Put the suction hose with lance, without tension and or twist, into the appropriate
container and secure it.
Hanging / connecting the pressure hose
Pull out the pressure hose (thin hose) with lance from the mounting in the floor plate
and insert it in the appropriate receptacle.
Put the pressure hose with lance, without tension and or twist, into the appropriate
container and secure it.
To prevent air from entering the medium, make sure that the pressure
hose with lance is always below the oil level in operation.
Check or compare the local mains voltage and frequency specifications with the
specifications on the type label of the unit.
Plug the power plug of the OF5 into a suitable power outlet.
The unit has a motor protection switch in the on / off switch. If the nominal current is
exceeded, the motor protection switch trips.
Checking the direction of rotation
Check the direction of rotation of the motor by switching it on briefly (jog mode). An
arrow on the fan cover shows the correct direction of rotation for the unit.
If the direction of rotation is opposite to the direction of the arrow, correct it using the
phase inverter contained in the connection plug, as shown in the diagram below.
After switching on the OF5, monitor the suction action via the transparent suction
hose.
If the unit is not feeding medium after several minutes of operation, the pump must
be pre-filled. Switch the motor off and fill the pump via the suction hose.
The special element receptacle renders it unnecessary to vent the filter housing.
Pay particular attention to the clogging indicator during operation. As soon as the
clogging indicator enters the red zone, the filter element must be changed
immediately.
The pressure relief valve in the pump returns the medium to the suction side if the
maximum operating pressure is exceeded.
The motor protection switch contained in the main switch permanently monitors the
nominal current and switches the unit off in case of overload.
► Never operate the filtration unit without a suction screen.
► Clean the suction screen regularly.
To protect the pump from coarse contamination or foreign bodies, a suction screen
is installed in the suction lance. Clean the suction screen regularly and check it
immediately in the event of insufficient suction or delivery action.
► Use only filter elements with the type code suffix -KB
(for example: 1300 R 003 BN4HC /-KB)
Depending on the version, the unit has an optical back-pressure indicator (2)
(red/green) or a scale in the filter cover. The version with switchover may have an
optional differential pressure gauge (1).
Change the filter element as soon as the back-pressure indicator or differential
pressure gauge is in the red area.
When decommissioning and/or disposing of the unit, observe all local guidelines and
regulations pertaining to occupational safety and environmental protection. This
applies in particular to the oil contained in the unit, to components coated in oil and
to electronic components.
After disassembling the unit and separating the various materials, reuse them or
dispose of them properly in accordance with local regulations.
E = Standard, pressure gauge
B = Differential pressure indicator - visual (VM2B.1)
C = Differential pressure indicator - electrical (VM2C.0)
D = Differential pressure indicator, visual/electrical (VM2D.0)
B, C and D not available for version "L"
We hereby declare that the following designated product, on the basis of its design and
construction, and in the version which we have brought to market, corresponds to the
fundamental safety and health requirements contained in the standards listed below.
Any modification of this product that is not coordinated with us in writing will cause this
declaration to lose its validity.
Designation Filter aggregate
Type OF 5 mobile series
Part no. -
Serial-no. -
EU Machinery Directive 2006/42/EC
EU Electrical Equipment Regulations 2006/95/EC
EMC Guideline 2004/108/EC
Safety of machinery and devices EN 12100-1/2
2009-12-22 Dr. Andreas Schunk
Date Name (CE-authorized person)
Executive director: Documentation Representative:
Mathias Dieter, Dipl.Kfm. Wolfgang Haering Mr. Günter Harge
Registered seat of company: 66280 Sulzbach / Saar - Germany c/o HYDAC International GmbH, Industriegebiet , 66280 Sulzbach / Saar