Hunter 94121A Owner's Manual

®
The
CEN TU RY
High Performance Oscillating Fan
ENGLISH
See page 2
Vea la página 11
ESPAÑOL
OWNER’S GUIDE
41746 05/02/2005
41746_CentFan_04.29.05.indd 1 5/2/05, 10:50:54 AM
Consulter la page 21
FRANÇAIS
IMPORTANT SAFETY INFORMATION
Read & Save These Instructions
WARNING
To reduce the risk of fi re or electrical shock, DO NOT use this fan with any solid-state speed control device.
CAUTION
When using electrical appliances, ba sic pre cau tions should al ways be tak en to reduce the risk of fi re, elec tric shock and per son al injury:
1. Read all instructions before using
ENGLISH
this fan.
2. Improper installation may result in the risk of fi re, elec tric shock or personal injury.
3. To prevent the risk of fi re and elec tric shock, DO NOT use the unit near windows. Rain and mois ture may cre ate an elec tri cal hazard.
4. The power plug must be removed from the pow er sock et when not in use, before clean ing, servicing, main te nance and before mov ing to another location.
5. DO NOT put fan in a damp place or where hu mid i ty is high—such as a bathroom.
6. The fan should be placed on a fl at, stable surface to avoid over­ turn ing.
7. Use fan only for intended use, as described in this in struc tion man u al.
8. To protect against electrical shock, DO NOT im merse unit, plug or cord in water or spray with liq uids.
9. Close supervision is necessary when any ap pli ance is used by or near children.
10. NEVER insert fi ngers, pencils or any other ob jects through the grill when the fan is running.
11. DO NOT operate any appliance with a dam aged cord or plug, af ter the appliance mal func tions or has been dropped or damaged in any manner.
12. To disconnect, grip plug and pull from wall outlet. NEV ER yank on cord.
13. ALWAYS use on a dry surface.
14. This product is intended for house­ hold use only and not for commer­cial or industrial use.
15. DO NOT operate fan in the pres­ ence of explosive and/or fl am­ ma ble fumes.
16. DO NOT place fan or any parts near an open fl ame, cook ing or any other heating appliances.
17. DO NOT use near curtains, plants, window treatments, etc.
18. Never operate the fan if the grills are not properly installed. Operat­ing the fan without the grills could result in serious in ju ry.
19. The appliance is not intended for use by young children or infi rm persons without supervision. Young children should be super­vised to ensure that they do not play with the appliance.
20. This appliance has a grounded three-prong plug and is suitable for ground ed receptacle use only. An adapter is available for con­ nect ing three-blade ground ing­type plugs to two-slot re cep ta cles. The adapter must be properly grounded. DO NOT attempt to defeat the purpose of this safely feature.
2 41746-01 05/02/2005
41746_CentFan_04.29.05.indd 2 5/2/05, 10:50:56 AM
WELCOME UNPACKING
Thank you for choosing the Hunter Century Pedestal Fan. This manual gives you complete instructions for using your fan. Here are some the features you will enjoy with your fan:
• An attractive design that enhances any decor
• A powerful Hunter motor for max­ i mum air fl ow
• Three speeds to adjust your com­ fort level
Before installing your fan, record the following information for your re­cords and for warranty assistance.
Model Name ___________________
Date Code _____________________
Date Purchased _________________
Where Purchased________________
_______________________________
As you unpack the fan, save the car ton and packing materials in case you want to move or ship the unit in the future.
Carefully remove all items from the box.
NOTE: It is best to have someone hold the box while you lift the fan and the protective packaging out of the carton.
Make sure all shipping materials are removed from fan before operating.
ENGLISH
Please attach your
receipt or a copy of your
receipt to this manual
for future reference.
41746-01 05/02/2005 3
41746_CentFan_04.29.05.indd 3 5/2/05, 10:50:56 AM
GROUNDING IN STRUC TIONS
This appliance is for household use only and may be plugged into any 120-volt AC electrical outlet (or­ di nary household current). DO NOT use any other type of outlet.
WARNING
This unit is suitable for ground­ ed receptacle use only.
The cord has a grounded plug as shown in Figure 1. An adapter, as shown in Figure 2, is available for
ENGLISH
con nect ing three-blade grounding­type plugs to two-slot receptacles. The green ground ing lug extending from the adapter must be con­nected to a permanent ground such as a prop er ty grounded outlet box. The adapter should not be used if a three-slot grounded re cep ta cle is avail able.
LINE CORD SAFETY TIPS
1. NEVER pull or yank on the cord or the appliance.
2. To insert plug, grasp it fi rmly and guide it into the outlet.
3. To disconnect the appliance, grasp the plug and remove it from the outlet.
4. Before each use, inspect the line cord for cuts and/or abrasion marks. If any are found, the ap­ pli ance should be serviced and the line cord replaced. Please re turn it to our Service De part ­ment or to an authorized service rep re sen ta tive.
5. NEVER wrap the cord tightly around the appliance, as this could place undue stress on the cord where it enters the ap pli ­ance and could cause it to fray and break.
6. DO NOT operate appliance if the line cord shows any dam­age, if the appliance works in ter mit tent ly or stops working entirely.
Grounded Plug
Grounding Pin
4 41746-01 05/02/2005
41746_CentFan_04.29.05.indd 4 5/2/05, 10:50:56 AM
Grounded Outlet
Box Cover
Adapter
Grounding Means
Metal Screw
Grounded Outlet Box Cover
FIGURE 2FIGURE 1
ASSEMBLY
1. With the base resting on the fl oor, place the base cover over the base. See Figure 3.
2. Slide the round cover support cap onto the bottom of the tele­ scop ing pole before placing it in the base.
3. Place the telescoping pole into the base, making sure the plug con nec tor goes through the base, then tighten the pole into the base by twist ing clockwise.
4. Raise the support cap and base cover and locate the setscrew in the neck of the base.
5. Tighten the pole setscrew fi rmly against the telescoping poles with the included Allen Wrench until it stops.
6. Lower the base cover back over the base.
7. Install the cover support cap into the base by twisting clock­wise until tight.
8. Lean the base onto its side care­ ful ly.
9. Match the polarized plug con­ nec tors, by aligning the sticker in di ca tors, from the telescoping pole and the connector from the elec tri cal cover and connect.
10. Remove one of the black cover assembly screws from the base and loosen the other three black cover assembly screws.
11. Place the electrical cover against the base and align the keyslots on the electrical cover with the three loosened black cover as­sembly screws. Rotate the elec­trical cover counterclockwise. See Figure 4.
12. Install the fourth black cover as­sembly screw. Securely tighten all four black cover assembly screws to attach the electrical cover to the base.
13. Hold the wall plug out of the way and stand the fan upright.
ENGLISH
Telescoping Pole
Cover Support Cap
Base Cover
Pole Setscrew
Base
FIGURE 3
41746-01 05/02/2005 5
41746_CentFan_04.29.05.indd 5 5/2/05, 10:50:57 AM
Electrical Cover
Telescoping Pole
Black Cover Assembly Screw
FIGURE 4
Keyslots
Base
Wall Plug
continued
ASSEMBLY CONTINUED
14. While supporting the fan mo­tor with one hand, loosen the ad just ment grip on the pole by turn ing counter clockwise and raise the top pole slightly. Twist the grip clockwise to stabilize the pole.
15. Locate the plug connector in the top of the telescoping pole and the plug connector from the fan motor.
16. Hold the fan motor over the tele scop ing poles and connect
ENGLISH
the plugs. See Figure 5.
17. Lower the motor over the tele­ scop ing poles aligning the three
Grille Ring
Front Grille
Tabs
Blade Assembly
holes in the fan motor mount with the three in the poles.
CAUTION: Make sure that all
wires remain inside the pole.
18. Install the 35mm motor mount­ ing screw through the pole and motor mount placing the head of the screw in the in dent ed area on the mo tor mount and se cure ly tighten.
19. Install a setscrew into the re­ main ing hole and tighten.
20. Remove the mounting screw on the upper left side of the motor face.
Grille Assembly
Back Grille
Screws
Bracket
Interlock Switch
Motor Face
Fan Motor
Ring Tabs
Ring Screws
Hunter Logo
Tabs
Motor Shaft
Motor Mount
Motor Mount Setscrew
35mm Motor Mounting Screw
Telescoping Pole
Adjustment Grip
FIGURE 5
6 41746-01 05/02/2005
41746_CentFan_04.29.05.indd 6 5/2/05, 10:50:58 AM
21. Align the keyhole slots in the back grille with the three screws re main ing in the motor face and place the back grill onto the screws with the washers in front of the grille, next to the head of the screw.
28. Place the bracket on the inter­lock switch over the back and front grille, aligning the holes in the bracket with the holes in the tab on top of the front grille. Install the two grille assembly screws.
22. Rotate the back grille clockwise to situate the screws in the nar­row ends of the keyhole slots.
23. Install the fourth screw into the remaining hole and tighten all screws.
24. Place the blade assembly over the motor shaft lining up the blade as sem bly setscrew on the back of the blade shaft with the rectangular indentation in the motor shaft. Rotate the motor shaft as needed.
25. Tighten the blade setscrew so that it sits in the rectangular in­ den ta tion, preventing the blades from touching the back grille or coming off the shaft. Gently pull the blades back and forth to check if the setscrew is in the right place.
26. With the Hunter logo facing forward, engage the tabs in the lower part of the front grille into the rim of the back grille.
29. Place the grille ring over the two grille rims leaving the open­ing at the bottom and the ring screw on the back side of the fan.
30. Latch the two sides of the ring together and secure with the ring screw. The ring screw should be installed through the thin side of the ring tabs to the thick side of the ring tabs.
Interlock Switch
Hole in motor face
ENGLISH
27. Insert the interlock switch into the hole on the top of the mo­tor face. See Figure 6.
41746-01 05/02/2005 7
41746_CentFan_04.29.05.indd 7 5/2/05, 10:51:02 AM
FIGURE 6
Fan Motor
OPERATION
This appliance is for household use only.
1. Place the fan on a dry, safe, fl at sur face where it cannot fall or be pulled by the cord.
2. Plug the fan into a grounded 120-volt AC electrical outlet (or di nary household current). DO NOT use any other type of outlet. Make sure that the rated voltage of the fan is the same as the power source before plug­ ging it into the power source.
ENGLISH
3. Turn the fan “ON” or “OFF” by rotating clockwise or coun­ ter clock wise the Pow er/Speed Con trol. The pow er should al­ways be OFF be fore un plug ging the fan.
4. To select the speed, move the Pow er/Speed Control from OFF to the desired speed setting: O (off), I (low), II (medium), III (High).
7. To adjust the height of your fan, while holding the top pole securely with one hand, loosen the grip on the telescoping pole by twisting counterclockwise. While supporting the fan motor, raise or lower the top pole to suit your needs. Tighten the grip on the pole by twisting clock­wise until it stops.
5. To control the upward and down ward direction of air fl ow, loosen the screw on the side of the fan housing neck. Adjust to the desired angle and tighten the screw.
6. To make the fan oscillate, push the oscillation knob down. To stop oscillating, pull the os cil ­la tion knob up. The oscillation knob is located on the top of the fan hous ing, near the handle.
8 41746-01 05/02/2005
41746_CentFan_04.29.05.indd 8 5/2/05, 10:51:05 AM
MAINTENANCE
This fan is permanently lubricated and will not require ad di tion al lu bri ­ca tion (oil) for the life of the fan.
This fan re quires little maintenance and contains no user ser vice able parts. DO NOT try to fi x it yourself. Contact qual i fi ed service personnel if servicing is needed.
TO CLEAN:
1. Before cleaning, turn fan off and unplug from electrical out­let. Wipe off excess dust with a lintfree cloth.
2. To ensure adequate air cir cu ­la tion to the motor, keep vents lo cat ed at the rear of the mo­tor hous ing free from dust ac­ cu mu la tion. A vacuum cleaner hose can be used to clean these vents.
3. DO NOT immerse the fan in wa­ ter or any other liquid.
CLEANING GRILL AND BLADE:
3. To disassemble the blade assem­bly, loosen the setscrew behind the fan blades and pull the blades off of the motor shaft.
4. Grills and blades may be cleaned with mild soap and wa ter.
5. Use a soft, slightly damp cloth to wipe the remaining fan parts.
6. DO NOT allow water or any oth er liquid to get into the mo­ tor housing or base.
7. Reassemble the fan after blades and grills have dried com plete ly. First, replace the blades. When replacing the blade screw, you should feel some resistance as the screw engages the bar. Next, align the grills, replace the interlock switch, replace the ring, place the hook in the hole and replace the screw.
8. DO NOT plug fan into an elec­ tri cal outlet until it has been fully reassembled.
ENGLISH
1. Turn the fan off and unplug from the electrical outlet.
2. To disassemble the grill, loosen the ring screw at the bottom of the grilles and remove the ring. Remove the front grille by re­moving the interlock switch.
41746-01 05/02/2005 9
41746_CentFan_04.29.05.indd 9 5/2/05, 10:51:06 AM
STORAGE TROUBLESHOOTING
®
1. Disassemble and clean fan be­ fore storing.
2. ALWAYS store the fan in a dry place.
3. NEVER store the fan while it is still plugged in.
4. NEVER wrap the cord tightly around the fan.
5. DO NOT put any stress on the cord where it enters the fan, as it could cause the cord to break.
ENGLISH
PROBLEM
• Fan will not work.
SOLUTION
• Make sure the interlock switch is properly installed as directed in the assembly instructions.
PROBLEM
• Fan will not oscillate.
SOLUTION
• Push down on knob on top of mo­ tor housing to activate os cil la tion.
PROBLEM
• Can not adjust the angle of the fan.
SOLUTION
• Loosen the screw on the side of the fan neck. Adjust to the desired angle and tighten the screw.
If you have tried these trou ble ­shoot ing solutions and still have trouble, visit our Web site at http: //www.hunterfanglobal.com.
HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS, TN 38114, USA
Printed in China
10 41746-01 05/02/2005
41746_CentFan_04.29.05.indd 10 5/2/05, 10:51:06 AM
Loading...
+ 22 hidden pages