Hunter 34257 Owner's Manual

The Care Free® Ultra
Evaporative Humidifi er
ENGLISH
See page 2
Vea la página 15
ESPAÑOL
Model 34257
www.hunterfan.com
41786 08/04/2005 1 ©2005 HUNTER FAN CO.
41786-01/-02_rev 08.01.05.indd 1 8/4/05, 4:05:34 PM
READ AND SAVE THESE INSTRUCTIONS
Important Safety Instructions:
Read all instructions before
using this humidifi er.
CAUTION: To avoid electrical shock
and/or fi re, please read all instruc­tions before use.
Thank you for purchasing the Care Free
Ultra Evaporative Humidifi er by Hunter Fan Company. Please read and save these instructions to receive maximum benefi t and performance from your humidifi er.
1. This humidifier may not work prop-
erly on an uneven surface. ALWAYS place this humidifi er on a fi rm, level and water resistant surface. ALWAYS place the humidifi er at least six (6) inches away from walls and heat sources such as stoves, radiators or heaters.
2. ALWAYS place the humidifier in an
area that is out of the reach of children.
3. Before using the humidifier, ex­tend the cord and inspect for any sign of damage. DO NOT use the product if the cord has been damaged.
4. This product has a polarized plug as a safety feature (one blade is wider than the other). This plug will fi t into a polarized outlet only one way. If the plug does not fully fi t into the outlet, reverse the plug. If it still does not fi t, contact a qualifi ed electrician. DO NOT attempt
®
to defeat or override this feature.
5. ALWAYS unplug and empty the humidifi er when it is not in operation or while it is being cleaned.
6. DO NOT tilt or move the humidifier while it is in operation. Never move the humidifi er while there is water in the tank. Empty the water tank, turn the unit off, and unplug the unit before moving.
7. In addition to routine maintenance which may be required, this humidifi er requires seasonal cleaning. Refer to and follow the instructions for CLEANING
THE HUMIDIFIER AND THE WATER TANK.
8. This unit was designed to be used with distilled and/or tap water. DO NOT add scented oils, perfumes or fragrance additives to the water.
How the Care Free® Ultra
Evaporative Humidifi er Works
The Care Free® Ultra Evaporative Humidifi er has a unique, patented design with several innovative features:
• Wickless Humidifi er – Hunter’s exclusive
system does not require a wick to create humidity. Water is transported up the tube and is dispersed by centrifugal force against the Atomizer. The tiny water particles cre­ated from this impact are then evaporated by the oncoming air stream and the moist air is released through the exhaust vents beneath the Water Tank.
41786-01 08/04/2005 2 ©2005 HUNTER FAN CO.
41786-01/-02_rev 08.01.05.indd 2 8/4/05, 4:05:37 PM
• Simple Pump System – By dispersing wa-
ter via centrifugal force through openings in the funnel pump, stagnant water in the reservoir is eliminated and the buildup of mineral residue that can clog conventional pump systems and impede performance is eliminated.
• Built-In Antimicrobial Properties – The
plastic parts in this humidifi er and the fi lter have built-in antimicrobial properties to in­hibit the growth of bacteria, mold and fungi that may affect these parts.
NOTE: The antimicrobial properties built-
into this humidifi er do not extend to the water, humidifi ed air or users. Conduct routine cleaning and maintenance based upon use and individual conditions.
• No White Dust – The Care Free
®
Ultra Evaporative Humidifi er produces no white dust that can settle on furniture or be inhaled.
NOTE: Yo u may notice mineral deposits
accumulating in the tank base or on other components. This is normal and comes with regular usage conditions. If you would like to remove these deposits and maintain humidifi er performance, please see the section CLEANING THE HUMIDI- FIER AND THE WATER TANK.
Assembly of Humidifi er Parts
ATTENTION: Before operating the unit, remove the tape strips located on the bottom of the power pack. These tape strips are used to secure the pump components during shipment and should be removed prior to operation. See Figure 1.
Tape
Figure 1
1. Remove the Care Free tive Humidifi er from its packaging.
2. Select a location for your humidifier. The location should be fl at, hard, water­resistant and at least six (6) inches away from walls and sources of heat.
HUNTER WILL NOT ACCEPT RESPONSI-
BILITY FOR DAMAGE DUE TO WATER SPILLAGE.
3. Remove the Lower Reservoir (marked with the number 2) from the Water Tank and Upper Reservoir (marked with the number 1). See Figure 3.
®
Ultra Evapora-
Water Tank
Tank Cap
Upper Reservoir
Power Pack
Lower Reservoir
Figure 2
4. Set the Lower Reservoir on the flat, hard surface you have chosen.
NOTE: Once the unit has been fi lled with
water and is operating, you should not use the Upper Reservoir handles or Water Ta nk handles to pick up and relocate the humidifi er without emptying all water from the humidifi er. Prior to moving the humidi­fi er, check the water window in the Lower Reservoir for water. If there is water in the Lower reservoir, remove the Water Tank and Upper Reservoir and drain all water.
continued
ENGLISH
41786-01 08/04/2005 3 ©2005 HUNTER FAN CO.
41786-01/-02_rev 08.01.05.indd 3 8/4/05, 4:05:38 PM
Lower Reservoir
Water Tank
Water Tank
Upper Reservoir
Tab
Upper Reservoir
Figure 3
5. Lift the Upper Reservoir (marked with the number 1) and Water Tank and place them on top of the Lower Reservoir (marked with the number 2) so that the two tabs in the Lower Reservoir snap into the Upper Reservoir. See Figure 3.
6. Take the Water Tank to a sink or tub to fi ll with water.
7. Unscrew the Tank Cap by twisting it counterclockwise and fi ll the Water Tank with cool water. NEVER USE HOT WATER. See Figure 4.
Tank Cap
Lower Reservoir
Tank Cap
Water Tank
Figure 5
9. Carrying the Water Tank by the two upper handles on the top of the Tank, posi­tion the Water Tank so that the notch in the back fi ts over the power supply cord and the Ta nk Cap in front fi ts into the cut-out area of the Power Pack. See Figure 6.
Water Tank
Figure 4
8. Replace the Tank Cap by screwing it back onto the Water Tank clockwise. Se­curely tighten the Tank Cap and make sure
Tank Cap
Cut-out area of power pack
Power pack
it is properly sealed. See Figure 5.
Figure 6
41786-01 08/04/2005 4 ©2005 HUNTER FAN CO.
41786-01/-02_rev 08.01.05.indd 4 8/4/05, 4:05:39 PM
Figure 7
Do not carry the water tank by the exhaust vents.
Upper Handle
Exhaust Vents
NOTE: Do not carry the Water Tank by the
exhaust vents. See Figure 7.
10. If the Water Tank is properly seated, you will see air bubbles fl owing up into the tank. If you do not see air bubbles, reposition the Water Tank as instructed above. Make sure the Power Knob is set to OFF and plug the humidifi er into the wall outlet.
CAUTION: Never plug in the humidifi er
while your hands are wet, as electric shock could occur.
11. Thread the power cord through both power cord clips on the back of the hu­midifi er.
12. Turn the Power Knob to the desired set­ting.
NOTE: If the Water Tank is not seated
properly on the Power Pack, it will not turn on.
ENGLISH
41786-01 08/04/2005 5 ©2005 HUNTER FAN CO.
41786-01/-02_rev 08.01.05.indd 5 8/4/05, 4:05:40 PM
Loading...