Hunter 33283 Owner's Manual

English
English
Inglés
The Care Free
®
Evaporative Humidifier
Model 33283
see page 2
ESPAÑOL
vea la página 7
FRANÇAIS
voir la page 13
©2008 HUNTER FAN CO. 43050-01 04/14/2008
©2008 HUNTER FAN CO. 43050-01 06/04/08
2
CONTENTS
Safety Instructions .....................................................................2
How the Humidifier Works .........................................................2
Humidifier Parts .........................................................................3
Humidifier Features ................................................................... 3
Using Your Humidifier ................................................................ 3
Refilling the Water Tank .............................................................4
Cleaning the Humidifier ............................................................. 4
Humidifier Troubleshooting ........................................................5
Service Parts ............................................................................. 5
Other Home Comfort Products from Hunter ..............................5
Español......................................................................................6
Français ................................................................................... 12
SAFETY INSTRUCTIONS
The Care Free® Evaporative Humidifier has a unique patented design with several innovative features:
• Low Maintenance – Other humidifiers have paper filters
that need to be replaced every few months. Our exclusive PermaWick™ filter saves time and money. It’s designed to last season after season, saving up to $45 a year. No wet paper odors either.
• Pump System – By dispersing water from the top of the
PermaWick™ filter, stagnant water around the PermaWick™ filter is eliminated, and the buildup of mineral residue that can
clog the filter and impede performance is eliminated.
NOTE: The filter has a coating on the wick which may make it appear old or used, but is actually new.
• Built-in Antimicrobial Properties – The plastic parts and the
PermaWick™ filter have built-in antimicrobial properties to inhibit the growth of bacteria, mold and fungi that may affect these parts.
NOTE: This product contains antimicrobial properties which are built-in to inhibit the growth of bacteria which may affect the plastic and PermaWick™ filter in the humidifier. These properties do not extend to the water, humidified air or users. Conduct routine cleaning and maintenance based upon use and individual conditions.
• No White Dust – The Care Free® Humidifier Plus Evaporative
Humidifier produces no white dust that can settle on furniture or be inhaled.
NOTE: You may notice mineral deposits accumulating in the tank base or on the PermaWick™ filter. This is normal and does not affect performance. If you would like to clean these
deposits away, please see CLEANING THE HUMIDIFIERAND
WATER TANK.
HOW THE HUMIDIFIER WORKS
Important Safety Instructions:
Read all instructions before using this
humidifier.
1. This humidifier may not work properly on an uneven
surface. ALWAYS place this humidifier on a firm, level, and water resistant surface. ALWAYS place the humidifier
at least six (6) inches away from walls and 3 ft. from heat sources such as stoves, radiators, or heaters.
2. ALWAYS place the humidifier in an area that is out of the
reach of children.
3. Before using the humidifier, extend the cord and inspect for any signs of damage. DO NOT use the product if the
cord has been damaged.
4.This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. DO NOT attempt to defeat
or override this safety feature.
5. ALWAYS UNPLUG AND EMPTY the humidifier when it is
not in operation or while it is being cleaned.
6. DO NOT tilt or move the humidifier while it is in operation.
Never move the humidifier while there is water in the tank. Empty the water tank, turn off, and unplug the unit before moving.
7. In addition to routine maintenance which may be required, this humidifier requires seasonal cleaning. Refer to and
follow CLEANING THE HUMIDIFIER AND THE WATER
TANK instructions.
8. This unit is designed to be used with distilled and/or tap
water. DO NOT add scented oils, perfumes, or fragrance
additives to the water.
Thank you for purchasing The Care Free® Humidifier Plus Evaporative Humidifier by Hunter Fan Company. Please read and save these instructions to receive the maximum benefit and performance from your humidifier.
TABLE OF CONTENTS
©2008 HUNTER FAN CO. 43050-01 06/04/08
3
HUMIDIFIER PARTS
Figure 1
Base
PermaWick™
Filter
PermaWick™
Filter Frame
Tank
Cap
Main
Housing
Power/Speed
Control
Humidistat
Controls
Water
Tank
Easy Tote
Handle
Adjustable Humidistat: Enables you to set a desired maximum humidity level. Once this level is reached, the unit will shut off until the humidity level drops. NOTE: The humidifier may not be running because the humidistat setting may need to be adjusted.
Power/Speed Control: Turns the humidifier ‘ON’ and ‘OFF’. The power should always be off before unplugging the humidifier, moving the humidifier, or refilling the water tank.
Power Light: The light will be illuminated when the power is
on.There are 2 fan speeds, high and low.
NiteGlo™ Night Light Control: Turns the night light ‘ON’ and ‘OFF’. The night light can be turned on even if the humidifier fan is turned off.
HUMIDIFIER FEATURES
Figure 2
Power
Light
Power/Speed
Control
Adjustable
Humidistat
Control
NiteGlo™
Night
Light
Control
1. Remove The Care Free® Evaporative Humidifier from its packaging. Read and Save the Instructions.
2. Place the humidifier on a hard, flat, water resistant surface. Always place the humidifier at least six (6) inches away from walls and sources of heat.
3. Lift the main housing to confirm that the PermaWick™ filters
are placed upright in the slots. Replace the main housing. (See Figure 1.)
4. Remove the water tank and take it to the sink or tub to fill.
5. Turn the tank upside down and unscrew the tank cap by turning it counterclockwise. Fill the water tank with cool water
and replace the tank cap (Never use hot water). Be sure not
to fill the tank to overflowing as water damage may occur to furniture or flooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE.
6. Carry the tank back to the humidifier. Turn the tank upright and place the full tank on the unit and allow the water to fill
the bottom tray. Be sure that the tank is seated properly in
the base. If the tank is properly located on the base, you will see air bubbles flowing up into the tank.
7. With the power control knob in the ‘OFF’ position, plug the humidifier into the wall.
CAUTION: Never plug in the Humidifier while your hands are wet as Electric Shock could occur.
8. Once the water is at the proper level, the tank will stop
bubbling. Run the unit on “HI” speed for 11⁄2 minutes for
optimum pump operation. Set the unit to the desired speed.
9. You can choose the desired humidity output by adjusting the Adjustable Humidistat knob. In a very dry room, the “HI” setting should be used to quickly achieve a comfortable level of humidity. Once the room is comfortable, you can turn the Adjustable Humidistat down. Selection of your desired humidity level is a personal choice and you may have to adjust the dial to find the level where you feel most comfortable. To begin with, we suggest you try a middle location between the lowest and the maximum setting. Then, adjust the level to suit your needs.
10. When the humidity reaches the level you have set, the
Humidifier will shut off. The humidifier will not output humidity while the humidity in the room is at the selected humidity level. When the humidity in the room drops below the selected level, the humidifier will cycle on again.
11. Follow REFILLING THE WATER TANK directions.
12. Use the control button to turn the night light off and on.
The night light can be operated even if the humidifier fan is turned ‘OFF’.
Using Your Humidifier
©2008 HUNTER FAN CO. 43050-01 06/04/08
4
1. When the water tank level is low, turn the humidifier ‘OFF’, and unplug.
2. Remove the tank and take it to the sink or tub to refill.
3. Turn the tank upside down and unscrew the tank cap by turning it counterclockwise. Empty the tank, refill with fresh cool water (never use hot water), and replace the tank cap.
Be sure not to overfill the tank as water damage may occur
to furniture or flooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE TO PROPERTY CAUSED BY WATER SPILLAGE.
4. Carry the tank back to the humidifier. Turn the tank upright
and place it on the humidifier. Be sure that the tank is seated
properly in the base. If the tank is properly located on the base, you will see air bubbles flowing up into the tank.
5. Place the full tank on the unit and allow the water to fill the bottom tray. The water is at the proper level in the bottom tray when the tank stops bubbling. Run the unit on “HI” speed for 11⁄2 minutes for optimum pump operation. Set the unit to the desired speed.
REFILLING THE WATER TANK
Cleaning the Humidifier
Many regions have hard water with high concentrations of
minerals. When water evaporates from The Care Free® Evaporative Humidifier, minerals may be left behind. These minerals can form a hard white scale which can be removed by following the cleaning instructions. The frequency of cleaning due to mineral build up can vary depending upon the quality of water you may have. Refer to Figure 1 for part names.
1. Turn the humidifier ‘OFF’ and unplug the unit.
2. Lift the main housing and remove the PermaWick Filter
Frame containing the PermaWick™ Filter. The motor is
attached to the main housing. Do not place the motor near water. Do not use a wet towel on the motor or motor housing
as electrical shock may occur.
3. The PermaWick™ Filter should be cleaned in a vinegar and water solution to remove any mineral buildup. Place in a solution of one (1) gallon of water and eight (8) ounces of undiluted white vinegar. Allow the filter to soak for 20 minutes.
4. After soaking, rinse it several times with clean water. Place the PermaWick™ Filter in a location where it can drip dry while you clean the other parts of your humidifier.
5. Remove the water tank from the base and empty any water that is left in the tank. Soak the base in a mixture of one (1) gallon of water and eight (8) ounces of vinegar for 20 minutes.
6. After soaking, wipe the base with a soft cloth or sponge to remove any mineral build up. Rinse with clean water several times. If you are planning on storing the humidifier, be sure
the base is completely dry.
7. Fill the water tank with one (1) gallon of water and eight ounces of undiluted white vinegar. Replace the tank cap and shake the tank vigorously until all interior surfaces of the tank have been exposed to the water/vinegar mixture.
8. Empty the tank of the water/vinegar mixture. Rinse it several times with clean water and then replace the tank cap. If you are planning on storing the humidifier, dry it inside and out, leaving the cap off to allow the tank to completely dry. Continue to clean the other parts of your humidifier.
9. Remove the water diffuser cap by squeezing the two tabs as shown in Figure 3. Rinse the cap in clean water to remove any debris. If the cap contains hard water residue, soak it in a mixture of one (1) quart of water and two (2) ounces of vinegar for 20 minutes. Rinse well and reinstall the
water diffuser cap. Do not expose motor or other electrical
components to water.
10. Wipe the surfaces of the main housing with a soft cloth.
11. Once all the parts are clean, reassemble the humidifier,
and follow the USING YOUR HUMIDIFIER instructions to
continue use. If you are storing the humidifier, make sure the parts are completely dry, reassemble, and store in a dry location.
Figure 3
Water Diffuser Cap
Ta b
Ta b
©2008 HUNTER FAN CO. 43050-01 06/04/08
5
HUMIDIFIER TROUBLESHOOTING
1. When I turn my humidifier on, it does nothing but hum.
Sometimes mineral deposits from the water can get trapped in the impeller of the humidifier. Follow the cleaning instructions on page 5.
2. I just bought my humidifier and I am setting it up, but my filter is filthy right out of the box.
Your filter has been treated with an anti-microbial agent that can give the appearance that the filter has mineral deposits on it.
3. My humidifier is starting to sound like a waterfall when I run
it. What should I do?
Follow the cleaning instructions on page 5. Your humidifier filter or water diffuser cap may be clogged.
4. I used to add chemicals to my water such as water softeners
or anti-microbial treatments. Do I need these with my Hunter
humidifier?
There is no need for additives with your Hunter humidifier. Anti-microbial properties have already been molded into the plastic in the unit. Adding these type of treatments could cause damage to the pump system.
5. If the unit is “Care Free”, why do I have to clean it?
All humidifiers require some maintenance. To keep your Hunter humidifier running it is necessary to clean minerals deposits from the filter and pump system.
6. How do I clean my Hunter humidifier and how often?
Refer to page 5 for cleaning instructions. Check your humidifier filters periodically and when you start to see crystal like formations coating the filter or inside of the unit, it is time to be cleaned.
To obtain a service part for your humidifier, call customer service at 1-888-830-1326 or e-mail us at Techsupport@ hunterfanhq.com. Please be prepared to tell the operator the model number of your humidifier and the name of the part you need to replace and the part number. Refer to Figure 1 for part names.
SERVICE PARTS
Filter Frame
95449
Base
98502
Water Tank
95857
Knob A
76729
Tank Cap
86113
Water Diffuser
74884
Filter
74080
To learn more about Hunter Fan Company products, please
see our web page at:
www.hunterfan.com
OTHER HOME COMFORT PRODUCTS
FROM HUNTER
Hunter Original®
QuietFlo™
True HEPA Air
Purifier
Programmable
Thermostat
HUNTER FAN COMPANY
2500 FRISCO AVENUE
MEMPHIS, TN 38114, USA
Loading...
+ 10 hidden pages