Hubbell KLV360, KLV365, KLV366, LTV765, LTV766 Installation Instructions Manual

...
Mini Vault - LTV765/766 & KLV360/361/365/366
Installation Instructions
P.O. Box 60080 16555 East Gale Ave. City of Industry, California 91716-0080 626/968-5666 • FAX 626/330-3861
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Do not overdrive fixtures with greater than 12 volts or fixture over-heating and short lamp life will occur. This can happen when using other than KIM KLV model transformers.
SAFETY WARNING: Low voltage fixtures can become very hot depending on the lamp wattage used.
Glass lenses and metal areas above and around the lamp can become hot enough to blister hands. DO NOT touch the lamp at any time. Particular care should be taken not to locate fixtures where small children can reach them if higher wattages are used. Lighted lamp is HOT!
CAUTION: Lamp gets HOT quickly. When relamping fixture avoid touching the lamp envelope with bare hands. If touching the lamp is necessary during installation, clean the envelope with alcohol and dry with a clean, soft cloth before burning. Contamination of the envelope may reduce lamp performance.
MAINTENANCE: To maintain light efficiency and prevent fixture overheating, glass lenses and enclosures must be kept clean and free of dirt, dust, leaves, trash and mineral deposits from water. Do not use these fixtures in submersible installations such as fountains or swimming pools. Do not install luminaire within 10 feet (1.52m) of a pool, spa, or fountain. Keep away from materials that may burn. DO NOT operate luminaire with missing or damaged lens.
NOTE: Keep the lamp free from impact while burning, as this may deform the filament and shorten the lamp life. All electrical work should be done by a qualified electrician. NOT INTENDED FOR INDOOR USE.
KEEP THIS SHEET FOR FUTURE REFERENCE.
Revision 7/16/10 ECN 100715008 Status 13 Part No. 95598
Make certain electrical supply is OFF before starting fixture installations.
LTV765/766 KLV360/361
1. Excavate hole in desired location approximately 12” in diameter and about 3” deeper than height of fixture.
CAUTION:
Do not exceed maximum wattage shown on fixture label.
2. Backfill hole with sand/gravel and soil for stabiity. Do not backfill with bark or vermicolite. (May be installed in concrete, for paved area installation use Trim Ring, part no. TR60.)
Tools Required: Flat Head Screwdriver F” Hex Wrench
!
Socket Head Cap Screw (5)
3. To open fixture, remove five (5) socket head cap screws, lens frame, lens and gasket.
Socket Head
Cap Screw (5)
!
KLV365 KLV366
!
Page 2 KIM Lighting • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
Mini Light Vault - LTV765/766 & KLV360/361/365/366
Installation Instructions
KIM LIGHTING LIMITED WARRANTY
When installed in accordance with Kim Installation Instructions and accepted trade practices, the following shall apply:
General Product Limited Warranty Coverage
All material and component parts used in the manufacture of Kim Products, are warranted to be free from defects of material and/or workmanship for a period of 1 year from date of sale, with the following exceptions:
Auxiliary Equipment
All auxiliary equipment (such as lamps, ballasts, and transformers) provided by and/or included in Kim Products shall carry the component manufacturer's warranty.
Copper, Bronze and Brass Landscape Components
Copper and Bronze Landscape fixture components shall be warranted against defects of material and/or workmanship, and failure due to corrosion, for a period of 25 years from date of sale. Kim Lighting's brass components are constructed from several brass parts that are manufactured by various methods at various times. Since brass naturally deepens in color as it ages through the normal oxidation process, these parts may exhibit subtle differences in coloration when the product is new. This is normal and expected. These color differences will be eliminated shortly after installation through the normal brass oxidation process.
Composite In-Grade Components
Composite In-Grade fixture components installed below grade, shall be warranted against defects of material and/or workmanship, and failure due to corrosion, for a period of 7 years from date of sale.
Aluminum Landscape Components
Aluminum Landscape fixture components not in direct contact with soil, shall be warranted against defects of material and/or workmanship for a period of 3 years from date of sale. Aluminum fixture components in direct contact with soil shall be warranted from defects of material and failure from corrosion for a period of 1 year from date of sale.
Stainless Steel Components
Stainless steel landscape components (Lens Rings) installed in the outdoor environment shall show signs of oxidation after 5 to 6 years of install and is dependent on the application and its environment. A proper maintenance and cleaning program will extend the beauty of the stainless steel.
Limit of Liability and General Conditions
Only products which are installed, used and maintained in accordance with applicable Kim instructions, specifications and accepted trade practices, are covered by the Kim Warranty. During the warranty period, with proof of purchase, Kim will repair or replace with the same or similar product, at Kim's option, without charge. Labor costs are the owner's responsibility and are excluded from this warranty. This warranty is void if the product is modified, tampered with, misapplied, poorly installed, improperly maintained, or subjected to abnormal conditions.
Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of fitness for a particular application. Kim Lighting shall not be liable to the purchaser for indirect or consequential damages.
LAMP INFORMATION
Catalog Lamp Max No. Type Watts
LTV765 LED 5 LTV766/KLV360 MR16 75 KLV361 LED 5 KLV365 MR16 75 KLV366 LED 5
How may we serve you better?
Please let us know. Visit our website at:
www.kimlighting.com
Your concerns are important to us.
To Relamp turn off/unplug and allow to cool before replacing lamp. Replace per chart at bottom of page. Lamp gets hot quickly. Contact only switch or plug when turning on.
1
2
3
4
5
5. Make sure gasket surface is clean and free of all dirt and debris so a leak free installation can be achieved. Replace lens, gasket and lens ring. Secure with socket head cap screws (5). Tighten opposing screws progressively and evenly.
Rotational
Locking
Screw
Vertical Locking Screw
4. Observe warnings & cautions! Install lamp of type and wattage shown on fixture label (not needed for LED fixtures). To aim lamp loosen vertical and rotational locking screws. Aim lamp bracket assembly to desired orientation & tighten screws.
Remember, the total wattage of all lamps connected to one transformer must not exceed the capacity of that transformer.
6. Connect fixture cable to main system cable using a Kim KLV410 Sealed Connector. (See KLV410 Sealed Connector Installation Instructions P/N
95484.)
Loading...