Huawei DRH3926A User Manual

Page 1
Issue
Draft A
Date
2013-04-26
Page 2
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
i
Copyright © Huawei Technologies Co., Ltd. 2013 . All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:
Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China
Website:
http://www.huawei.com
Email:
support@huawei.com
Page 3
Page 4
DRH Installation Guide
About This Chapter
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
iii
Purpose
Product Name
Product Version
DRH
V100R001 and later versions
This document describes the process of installing a DC DRH (referred to as DRH in this document). (DRHDistributed Remote Head)
Product Versions
The following table lists the product versions related to this document.
About This Chapter
Intended Audience
This document is intended for: Base station installation engineers
Organization
1 Changes in the DRH Installation Guide
This chapter describes the changes in the DRH Installation Guide.
2 Installation Preparations
This chapter describes the reference documents, tools, and instruments that must be ready before the installation. In addition, it specifies the skills and prerequisites that installation engineers must have.
3 Information About the Installation
Before installing a DRH, you must be familiar with its exterior, ports, indicators, installation options and installation clearance requirements.
4 Unpacking the Equipment
This chapter describes how to unpack and check the delivered equipment to ensure that all the materials are included and intact.
5 Installation Process
Page 5
DRH Installation Guide
About This Chapter
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
iv
The installation process involves installing a DRH and DRH cables, checking the DRH hardware installation, and powering on the DRH.
6 (Optional) Installing the Plastic Shells of the DRH
This section describes the procedure for installing the plastic shells of the DRH.
8 Installing the DRH
This chapter describes the procedure for installing the DRH. The DRH can be installed on a pole, U-steel, angle steel, wall, or an IFS06 . The procedure for installing the DRH varies depending on installation options.
9 Installing DRH Cables
This chapter describes the procedure for installing DRH cables.
10 Checking the DRH Hardware Installation
After a DRH is installed, check the hardware installation.
11 Powering On a DRH
After all the devices are installed, check the power-on status of a DRH. 12 Appendix This section describes the procedure for adding an easy power receptacle (pressfit type)
connector.
Page 6
DRH Installation Guide
Contents
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
v
Contents
1 Changes in the DRH Installation Guide ............................................................................... 1
2 Installation Preparations ......................................................................................................... 2
2.1 Reference Documents ................................................................................................................................ 2
2.2 Tools and Instruments ................................................................ ................................................................ 2
2.3 Skills and Requirements for Onsite Personnel ............................................................................................ 4
3 Information About the Installation ....................................................................................... 5
3.1 DRH Exterior ............................................................................................................................................ 5
3.2 DRH Ports ................................................................................................................................................. 6
3.3 DRH Indicators ......................................................................................................................................... 8
3.4 Installation Scenarios ................................................................................................................................. 9
3.5 Installation Clearance Requirements of a DRH ..........................................................................................18
4 Unpacking the Equipment .................................................................................................... 27
5 Installation Process ................................................................................................................ 29
6 (Optional) Installing the Plastic Shells of the DRH .......................................................... 30
7 Installing the DRH ................................................................................................................. 33
7.1 Mounting Kits for a DRH .........................................................................................................................33
7.2 Installing the DRH on a Pole .....................................................................................................................35
7.3 Installing the DRH on U-steel ...................................................................................................................47
7.4 Installing the DRH on Angle Steel ............................................................................................................52
7.5 Installing the DRH on a Wall ....................................................................................................................57
7.6 Installing a DRH on an IFS06 ...................................................................................................................64
8 Installing DRH Cables .......................................................................................................... 72
8.1 Cabling Requirements...............................................................................................................................73
8.2 Cable Connections ....................................................................................................................................76
8.3 Installation Process ...................................................................................................................................77
8.4 DRH Cable List ........................................................................................................................................78
8.5 Installing a DRH PGND Cable..................................................................................................................79
8.6 Installing a DRH RF Jumper .....................................................................................................................80
8.7 Installing a DRH Alarm Cable ..................................................................................................................84
8.8 Opening the Cover Plate of a DRH Cabling Cavity....................................................................................85
8.9 Installing a DRH Power Cable ..................................................................................................................86
8.10 Installing a CPRI Fiber Optic Cable ........................................................................................................88
Page 7
DRH Installation Guide
Contents
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
vi
8.11 Closing the Cover Plate of a DRH Cabling Cavity ...................................................................................91
9 Checking the DRH Hardware Installation ......................................................................... 93
10 Powering On a DRH ............................................................................................................ 94
11 Appendix ............................................................................................................................... 97
11.1 Adding a Tool-Less Female Connector (Pressfit Type) to the DRH Power Cable on the DRH Side ...........97
Page 8
DRH Installation Guide
1 Changes in the DRH Installation Guide
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
1
1 Changes in the DRH Installation Guide
This chapter describes the changes in the DRH Installation Guide.
01 (2013-04-26)
This is the first official release.
Page 9
DRH Installation Guide
2 Installation Preparations
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
2
2 Installation Preparations
Hammer drill (a φ12 bit)
ESD gloves
Vacuum cleaner
This chapter describes the reference documents, tools, and instruments that must be ready before the installation. In addition, it specifies the skills and prerequisites that installation engineers must have.
2.1 Reference Documents
Before the installation, you must be familiar with reference documents.
2.2 Tools and Instruments
You must prepare the following tools and instruments before the installation.
2.3 Skills and Requirements for Onsite Personnel
Onsite personnel must be qualified and trained. Before performing any operation, onsite personnel must be familiar with correct operation methods and safety precautions.
2.1 Reference Documents
Before the installation, you must be familiar with reference documents. The following reference documents are required during DRH installation:
DRH Hardware Description
DRH Installation Guide
2.2 Tools and Instruments
You must prepare the following tools and instruments before the installation.
Page 10
DRH Installation Guide
2 Installation Preparations
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
3
Heat gun
Phillips screwdriver (M3 to M6)
Flat-head screwdriver (M3 to M6)
Rubber mallet
COAX crimping tool
Wire stripper
Utility knife
Cable cutter
Adjustable wrench (size ≥ 32
mm [1.26 in.])
Torque wrench
Size: 16 mm (0.63 in.) and 32 mm (1.26 in.)
Combination wrench
Size: 16 mm (0.63 in.) and 32 mm (1.26 in.)
Level
Torque screwdriver
5 mm
5mm
(M3 to M6)
(M3 to M6)
Torque socket
Multimeter
Marker (diameter ≤ 10 mm [0.39 in.])
Measuring tape Inner hexagon wrench
5 mm
Hydraulic pliers
Page 11
DRH Installation Guide
2 Installation Preparations
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
4
2.3 Skills and Requirements for Onsite Personnel
Onsite personnel must be qualified and trained. Before performing any operation, onsite personnel must be familiar with correct operation methods and safety precautions.
Before the installation, pay attention to the following items:
The customer's technical engineers must be trained by Huawei and be familiar with the proper installation and operation methods.
The number of onsite personnel depends on the engineering schedule and installation environment. Generally, only three to five onsite personnel are necessary.
Page 12
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
5
3 Information About the Installation
Before installing a DRH, you must be familiar with its exterior, ports, indicators, installation options and installation clearance requirements.
3.1 DRH Exterior
This section describes the exterior and dimensions of a DRH.
3.2 DRH Ports
This section describes ports on the DRH panels. A DRH has a bottom panel, cabling cavity panel, and indicator panel.
3.3 DRH Indicators
This section describes six indicators on a DRH. They indicate the running status.
3.4 Installation Scenarios
A DRH can be installed on a pole, U-steel, angle steel, wall, or IFS06. Installation scenarios must meet heat-dissipation and waterproofing requirements of the DRH.
3.5 Installation Clearance Requirements of a DRH
This section describes the requirements for the installation clearance of a single DRH and multiple DRHs and the requirements for the installation spacing between DRHs.
3.1 DRH Exterior
This section describes the exterior and dimensions of a DRH.
Figure 3-1 shows a DRH.
Page 13
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
6
Figure 3-1 DRH exterior
Figure 3-2 shows DRH dimensions.
Figure 3-2 DRH dimensions
3.2 DRH Ports
This section describes ports on the DRH panels. A DRH has a bottom panel, cabling cavity panel, and indicator panel.
Figure 3-3 shows the ports on the DRH panels.
Page 14
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
7
Figure 3-3 Ports on the DRH panels
Item
Silkscreen
Remarks
(1) Ports in the cabling cavity
RTN(+)
Power supply socket NEG(-)
CPRI0
Optical/electrical port 0
CPRI1
Optical/electrical port 1
(2) Ports at the bottom
ANT_TX/RXA
TX/RX port A
ANT_RXB
RX port B
EXT_ALM
Alarm port
(3) Indicators
RUN
See 3.3 DRH Indicators.
ALM
ACT
VSWR
CPRI0
Table 3-1 describes ports and indicators on the DRH panels.
Table 3-1 Ports and indicators on the DRH panels
Page 15
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
8
Item
Silkscreen
Remarks
CPRI1
Indicator
Color
Status
Meaning
RUN
Green
Steady on
There is power supply, but the module is faulty.
Steady off
There is no power supply, or the module is faulty.
Blinking (on for 1s and off for 1s)
The board is functioning properly.
Blinking (on for
0.125s and off for
0.125s)
Software is being loaded to the module, or the module is not started.
ALM
Red
Steady on
Alarms are generated, and the module must be replaced.
Blinking (on for 1s and off for 1s)
Alarms are generated. The alarms may be caused by the faults on the related boards or ports. Therefore, you need to locate the fault before deciding whether to replace the module.
Steady off
No alarm is generated.
ACT
Green
Steady on
The module is running properly with TX channels enabled or the software is being loaded without DRH running.
Blinking (on for 1s and off for 1s)
The module is running properly with TX channels disabled.
VSWR
Red
Steady off
No Voltage Standing Wave Ratio (VSWR) alarm is generated.
Blinking (on for 1s and off for 1s)
VSWR alarms are generated on the ANT_RXB port.
The port for transmitting RET signals is determined by the software.
3.3 DRH Indicators
This section describes six indicators on a DRH. They indicate the running status. For detailed positions of DRH indicators, see 3.2 DRH Ports.
Table 3-2 describes DRH indicators.
Table 3-2 DRH indicators
Page 16
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
9
Indicator
Color
Status
Meaning
Steady on
VSWR alarms are generated on the ANT_TX/RXA port.
Blinking (on for
0.125s and off for
0.125s)
VSWR alarms are generated on the ANT_TX/RXA and ANT_ RXB ports.
CPRI0
Red or green
Steady green
The CPRI link is functioning properly.
Steady red
An optical module fails to transmit or receive signals because the optical module is faulty or the fiber optic cable is broken.
Blinking red (on for 1s and off for 1s)
The CPRI link is out of lock because of a failure in clock lock between two modes or mismatched data rates over CPRI ports.
Steady off
The optical module cannot be detected, or the optical module is powered off.
CPRI1
Red or green
Steady green
The CPRI link is functioning properly.
Steady red
An optical module fails to transmit or receive signals because the optical module is faulty or the fiber optic cable is broken.
Blinking red (on for 1s and off for 1s)
The CPRI link is out of lock because of a failure in clock lock between two modes or mismatched data rates over CPRI ports.
Steady off
The optical module cannot be detected, or the optical module is powered off.
3.4 Installation Scenarios
A DRH can be installed on a pole, U-steel, angle steel, wall, or IFS06. Installation scenarios must meet heat-dissipation and waterproofing requirements of the DRH.
Requirements for the Installation Scenarios
Application scenarios: To ensure proper heat dissipation of the DRH, the following requirements must be met:
The DRH cannot be installed in an enclosed cabinet without a cooling system.
The DRH cannot be installed in an enclosed camouflage box.
The DRH cannot be installed in an enclosed equipment room without a cooling system.
When multiple DRHs are installed in centralized mode, the minimum clearance requirements must be met. For details about the minimum clearance requirements, see
Clearances for Three or More DRHs and Installation Spacing Between DRHs.
Page 17
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
10
(1) DRH
(2) Installation support (pole, U-steel, angle steel, or wall)
If the DRH is improperly installed, heat dissipation of the DRH deteriorates and the DRH may not work properly, as shown in Figure 3-4.
Figure 3-4 Improperly installed DRHs
Method of installation:
To ensure the heat dissipation of the DRH and waterproofing of the ports at the bottom of the DRH, the vertical deviation angle of a DRH must be less than or equal to 10 degrees, as shown in Figure 3-5.
Figure 3-5 Requirements for the vertical deviation angle of a DRH
Page 18
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
11
Installing a DRH on a Pole
Figure 3-6 shows the diameter of a pole for installing a DRH.
Figure 3-6 Diameter of a pole
The diameter of a pole for installing a DRH ranges from 60 mm (2.36 in.) to 114 mm (4.49 in.). The recommended diameter is 80 mm (3.15 in.).
When the diameter of a pole ranges from 60 mm (2.36 in.) to 76 mm (2.99 in.), a maximum of three DRHs can be installed on the pole and the side-mounted installation is recommended.
Only a pole whose diameter ranges from 76 mm (2.99 in.) to 114 mm (4.49 in.) supports more than three DRHs.
The recommended thickness of the wall of a pole is 3.5 mm (0.14 in.) or above.
Figure 3-7 shows a single DRH installed on a pole.
Page 19
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
12
Figure 3-7 A single DRH installed on a pole
Figure 3-8 shows two DRHs installed on a pole.
Figure 3-8 Two DRHs installed on a pole
Installing a DRH on U-steel
Figure 3-9 shows U-steel specifications.
Page 20
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
13
Figure 3-9 U-steel specifications
U-steel supports the standard or reverse installation of a single DRH only.
Figure 3-10 shows a DRH installed on U-steel.
Figure 3-10 DRH installed on U-steel
Installing a DRH on Angle Steel
Figure 3-11 shows angle steel specifications.
Page 21
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
14
Figure 3-11 Angle steel specifications
Angle steel supports the standard or reverse installation of a single DRH only.
Figure 3-12 shows a DRH installed on angle steel.
Figure 3-12 DRH installed on angle steel
Installing a DRH on a Wall
The wall for installing DRHs must meet the following requirements:
When a single DRH is installed, the wall has a capacity of bearing at least four times the weight of the DRH.
Expansion anchor bolts must be tightened to 30 N·m (265.52 lbf·in.) so that the bolts stay secured without damaging the wall.
Page 22
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
15
It is recommended that the DRH be installed on a wall in standard mode.
When DRHs are installed on a wall outdoors in side-mounted mode, you are not advised to combine the mounting brackets for multiple DRHs, as shown in Figure 3-13. When DRHs are installed on a wall indoors in side-mounted mode, do not combine mounting brackets for multiple DRHs, as shown in Figure 3-14.
Figure 3-13 Correct installation of mounting brackets for multiple DRHs installed on an outdoor wall in side-mounted mode
Figure 3-14 Correct installation of mounting brackets for multiple DRHs installed on an indoor wall in side-mounted mode
Figure 3-15 shows a DRH installed on a wall.
Page 23
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
16
Figure 3-15 DRH installed on a wall
Installing a DRH on an IFS06
In an IFS06 scenario:
The upper and lower adjustable beams on an IFS06 can be moved up and down to fit for heights of DRHs.
The IFS06 supports at least three DRHs when the ambient temperature is higher than or equal to the lowest operating temperature of the DRH and at least 5°C (41°F) lower than the highest operating temperature of the DRH. The IFS06 supports a maximum of six DRHs when the ambient temperature is higher than or equal to the lowest operating temperature of the DRH and at least 10°C (50°F) lower than the highest operating temperature of the DRH.
The mounting brackets for multiple DRHs cannot be combined when the DRHs are installed on an IFS06, as shown in Figure 3-16.
Page 24
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
17
Figure 3-16 Correct installation of mounting brackets for DRHs installed on an IFS06
(1) Height-restricted scenario
(2) Height-unrestricted scenario
Figure 3-17 and Figure 3-18 show DRHs installed on an IFS06.
Figure 3-17 Three DRHs installed on an IFS06
Page 25
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
18
Figure 3-18 Six DRHs installed on an IFS06
(1) Height-restricted scenario
(2) Height-unrestricted scenario
3.5 Installation Clearance Requirements of a DRH
This section describes the requirements for the installation clearance of a single DRH and multiple DRHs and the requirements for the installation spacing between DRHs.
Clearance for a Single DRH
This section describes the recommended and minimum clearance for a single DRH.
Page 26
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
19
The recommended clearance ensures normal running and provides an appropriate space for operation and maintenance (OM). If there is sufficient space, leave the recommended clearance after installing the equipment.
The minimum clearance ensures normal running and heat dissipation, but OM activities such as checking indicator status and opening the cabling cavity cannot be properly conducted. If the installation space is restricted, leave the minimum clearance after installing the equipment.
Clearance for a Single DRH in Standard or Reverse Mode
Figure 3-19 shows the clearance for a single DRH in standard or reverse mode.
Figure 3-19 Clearance for a single DRH in standard or reverse mode
Page 27
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
20
Clearance for a Single DRH in Side-Mounted Mode
Figure 3-20 shows the clearance for a single DRH in side-mounted mode.
Figure 3-20 Clearance for a single DRH in side-mounted mode
Clearances for Three or More DRHs
This section describes the recommended and minimum clearances for three or more DRHs.
Page 28
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
21
The recommended clearances ensure normal running and provide an appropriate space for operation and maintenance (OM). If there is sufficient space, retain the recommended clearances.
The minimum clearances ensure normal running and heat dissipation but do not allow OM activities such as checking indicator status and opening the cabling cavity. If the installation space is insufficient, retain the minimum clearances after the installation.
Recommended Clearances for Three or More DRHs Installed on a Pole
Figure 3-21 shows the recommended clearances for multiple DRHs installed in centralized
mode.
Figure 3-21 Recommended clearances for three or more DRHs installed on a pole
Minimum Clearances for Three or More DRHs Installed on a Pole
Figure 3-22 shows the minimum clearances for multiple DRHs installed in centralized mode.
Page 29
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
22
Figure 3-22 Minimum clearances for multiple DRHs installed in centralized mode
Recommended Clearances for Three or More DRHs Installed on a Wall in Standard Mode
Figure 3-23 shows the recommended clearances for multiple DRHs installed on a wall in
standard mode.
Page 30
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
23
Figure 3-23 Recommended clearances for three or more DRHs installed on a wall in standard mode
Minimum Clearances for Three or More DRHs Installed on a Wall in Standard Mode
Figure 3-24 shows the minimum clearances for three or more DRHs installed on a wall in
standard mode.
Figure 3-24 Minimum clearances for three or more DRHs installed on a wall in standard mode
Page 31
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
24
Recommended Clearances for Three or More DRHs Installed on a Wall in Side-Mounted Mode
Figure 3-25 shows the recommended clearances for three or more DRHs side-mounted on a
wall.
Figure 3-25 Recommended clearances for three or more DRHs installed on a wall in side-mounted mode
Installation Spacing Between DRHs
This section describes the horizontal and vertical spacing between DRHs.
Recommended Horizontal Spacing Between DRHs
Figure 3-26 shows the recommended horizontal spacing between DRHs.
Figure 3-26 Recommended horizontal spacing between DRHs
Page 32
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
25
Minimum Horizontal Spacing Between DRHs
Figure 3-27 shows the minimum horizontal spacing between DRHs.
Figure 3-27 Minimum horizontal spacing between DRHs
Recommended Vertical Spacing Between DRHs
Figure 3-28 shows the recommended vertical spacing between DRHs.
Figure 3-28 Recommended vertical spacing between DRHs
Minimum Vertical Spacing Between DRHs
Figure 3-29 shows the minimum vertical spacing between DRHs.
Page 33
DRH Installation Guide
3 Information About the Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
26
Figure 3-29 Minimum vertical spacing between DRHs
Page 34
DRH Installation Guide
4 Unpacking the Equipment
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
27
Context
If ...
Then ...
The total number tallies with the packing list
Go to Step 2.
The total number does not tally with the packing list
Find out the cause and report any missing articles to the local Huawei office.
If ...
Then ...
The outer packing is intact
Go to Step 3.
The outer packing is severely damaged or soaked
Find out the cause and report it to the local Huawei office.
The shockwatch label is red
Stop unpacking the wooden crate, and then report it to the transportation company.
If ...
Then ...
Types and quantity of the article tally with those on the packing list
Sign the Packing List with the customer.
4 Unpacking the Equipment
This chapter describes how to unpack and check the delivered equipment to ensure that all the materials are included and intact.
When transporting, moving, or installing the equipment, components, or parts, you must:
Prevent them from colliding with doors, walls, shelves, or other objects.
Wear clean gloves, and avoid touching the equipment, components, or parts with bare hands, sweat-soaked gloves, or dirty gloves.
Procedure
Step 1 Check the total number of articles in each case according to the packing list.
Step 2 Check the exterior of the packing case.
Step 3 Check the type and quantity of the equipment in the cases according to the packing list.
Page 35
DRH Installation Guide
4 Unpacking the Equipment
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
28
If ...
Then ...
Either shipment shortage, wrong shipment or damaged articles.
Report to the local Huawei office.
To protect the equipment and prevent damage to the equipment, you are advised to keep the unpacked equipment and packing materials indoors, take photos of the stocking environment, packing case or carton, packing materials, and any rusted or eroded equipment, and then file the photos.
----End
Page 36
DRH Installation Guide
5 Installation Process
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
29
5 Installation Process
The installation process involves installing a DRH and DRH cables, checking the DRH hardware installation, and powering on the DRH.
Figure 5-1 shows the process of installing a DRH.
Figure 5-1 Process of installing a DRH
Page 37
DRH Installation Guide
6 (Optional) Installing the Plastic Shells of the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
30
6 (Optional) Installing the Plastic Shells of
(1) Screw
(2) Metal sheet
the DRH
This section describes the procedure for installing the plastic shells of the DRH.
Context
A DRH is equipped with a plastic shell only when necessary.
Procedure
Step 1 Use an M6 Phillips screwdriver to loosen the two screws on the metal sheet of the DRH and
remove the metal sheet, as shown in Figure 6-1.
Figure 6-1 Removing the metal sheet
Page 38
DRH Installation Guide
6 (Optional) Installing the Plastic Shells of the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
31
Step 2 Install a buckle on each side at the bottom of the DRH, and use an M4 torque wrench to
(1) Buckle
(2) Screw
tighten the screws on the buckles to 1.4 N•m (12.39 lbf•in.), as shown in Figure 6-2.
Figure 6-2 Installing buckles at the bottom
Step 3 Use four hex screws to secure the plastic shells onto the DRH and use an M6 hex key wrench
to tighten the screws to 2.8 N•m (24.78 lbf•in.), as shown in Figure 6-3.
Page 39
DRH Installation Guide
6 (Optional) Installing the Plastic Shells of the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
32
Figure 6-3 Installing the plastic shells of the DRH
----End
Page 40
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
33
7 Installing the DRH
This chapter describes the procedure for installing the DRH. The DRH can be installed on a pole, U-steel, angle steel, wall, or an IFS06 . The procedure for installing the DRH varies depending on installation options.
7.1 Mounting Kits for a DRH
This section describes the bracket assembly and the attachment plate for a DRH.
7.2 Installing the DRH on a Pole
One or more DRHs can be installed on a pole.
7.3 Installing the DRH on U-steel
This section describes the procedure and precautions for installing the DRH on U-steel. A DRH can be installed on U-steel secured on the ground. Each piece of U-steel allows only one DRH to be installed in standard or reverse mode.
7.4 Installing the DRH on Angle Steel
This section describes the procedure and precautions for installing the DRH on angle steel. A DRH can be installed on angle steel secured on the ground. Each piece of angle steel allows only one DRH to be installed in standard or reverse mode.
7.5 Installing the DRH on a Wall
This section describes the procedure and precautions for installing the DRH on a wall.
7.6 Installing a DRH on an IFS06
This section describes the procedure and precautions for installing a DRH on an IFS06.
7.1 Mounting Kits for a DRH
This section describes the bracket assembly and the attachment plate for a DRH.
Figure 7-1 shows the front and side of a DRH.
Page 41
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
34
Figure 7-1 Front and side view of a DRH
(1) Attachment plate
(1) Plastic cap
(2) Standard M10 nut
(3) Spring washer
(4) Thick flat washer
(5) Square-neck bolt
(6) Hoist clamp on the main bracket
(7) Main bracket
(8) Pole installation bracket
(9) Auxiliary bracket
-
Figure 7-2 shows the bracket assembly for a DRH.
Figure 7-2 12 L blade DRH mounting kit
Page 42
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
35
7.2 Installing the DRH on a Pole
One or more DRHs can be installed on a pole.
Installing a Single DRH
This section describes the procedure and precautions for installing a single DRH on a pole.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Procedure
Step 1 Determine a position for installing the mounting brackets.
If the pole must be installed on the ground, determine a position for installing the mounting brackets according to Figure 7-3.
Figure 7-3 Distance between the mounting brackets and the ground
It is recommended that the mounting brackets be installed at a height of 1200 mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.
Page 43
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
36
Step 2 Install the DRH mounting brackets, as shown in Figure 7-4.
Figure 7-4 Installing the DRH mounting brackets
Verify that the arrows on the mounting brackets are pointing up.
1. Adjust the position of the nut and remove one end of the square-neck bolt from the slot
on the auxiliary bracket.
2. Slide the mounting brackets onto the pole horizontally and insert the square-neck bolt
into the slot.
Step 3 Use a 16 mm (0.63 in.) M10 torque wrench to tighten the nuts to 40 N·m (354.03 lbf·in.) so
that the mounting brackets are secured onto the pole, as shown in Figure 7-5.
Tighten the nuts on the two square-neck bolts alternatively. After the main and auxiliary brackets are secured properly, measure the spacing between the brackets on both sides and ensure that the spacing is the same on the two sides.
Page 44
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
37
Figure 7-5 Securing the DRH mounting brackets
Step 4 Install the DRH onto the main bracket, as shown in Figure 7-6.
Figure 7-6 Installing the DRH onto the main bracket
Step 5 Use an inner hexagon torque screwdriver to tighten the captive screw into the holes on the top
of the attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in Figure 7-7.
Page 45
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
38
Figure 7-7 Securing the captive screw into the connection hole
----End
Installing Two DRHs
This section describes the procedure and precautions for installing two DRHs on a pole.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Procedure
Step 1 Install the first DRH onto the main bracket, as shown in Figure 7-8. For details, see Installing
a Single DRH.
Page 46
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
39
Figure 7-8 Installing the first DRH onto the main bracket
(1) Main bracket
(2) Pole installation bracket
Step 2 Use an M6 inner hexagon screwdriver to remove the four inner hexagon screws from the
second set of mounting brackets, and remove the main bracket from the auxiliary bracket, as shown in Figure 7-9.
Figure 7-9 Removing the DRH main bracket
Step 3 Install the removed main bracket on one side of the first main bracket, as shown in Figure
7-10.
Page 47
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
40
(1) Removed main bracket
The second main bracket must be installed with the opening ends of U-shaped slots on both sides facing downwards.
Figure 7-10 Installing the second main bracket
Step 4 Install the second DRH onto the main bracket, as shown in Figure 7-11.
Page 48
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
41
Figure 7-11 Installing the second DRH onto the main bracket
After installing each DRH on its main bracket, use an inner hexagon torque screwdriver to tighten the captive screw into the holes of the attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in
Figure 7-12.
Page 49
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
42
Figure 7-12 Securing the captive screw into the connection hole
(1) Screw
(2) Metal sheet
Step 5 Install the metal sheet for neighboring DRHs, as shown in Figure 7-13.
Figure 7-13 Installing the metal sheet
1. Use an M6 Phillips screwdriver to loosen the screw on the metal sheet farther from the
handle of the first DRH and remove the screw.
2. Use an M6 Phillips screwdriver to loosen the screw on the metal sheet closer to handle of
the first DRH. Then rotate the metal sheet to align the vacant hole in the metal sheet with a hole on the top of the second DRH.
3. Insert the removed screw into the hole on the top of the second DRH and use an M6
torque screwdriver to tighten the screw to 5 N·m (44.25 lbf·in.).
Page 50
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
43
----End
Installing Three or More DRHs
The section describes the procedure and precautions for installing three or more DRHs on a pole.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Context
Procedure
Step 1 Install the two DRHs, as shown in Figure 7-14. For details, see Installing Two DRHs.
A pole supports the installation of three, four, or six DRHs. The procedures for installing them are the same. Following is the procedure of installing four DRHs on a pole.
Figure 7-14 Two DRHs installed on a pole
Page 51
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
44
Step 2 Use an M6 inner hexagon screwdriver to remove the four inner hexagon screws from the
(1) Main bracket
(2) Pole installation bracket
second set of mounting brackets, and remove the main bracket from the auxiliary bracket, as shown in Figure 7-15.
Figure 7-15 Removing the DRH main bracket
Step 3 Install the third main bracket and install the third DRH onto the third main bracket. Then use
an inner hexagon torque screwdriver to tighten the captive screw into the connection holes on the top of the attachment plate and main bracket for the DRH, with a torque of 5 N·m (44.25 lbf·in.), as shown in Figure 7-16.
The third main bracket must be installed with the opening ends of U-shaped slots on both sides facing downwards.
Page 52
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
45
Figure 7-16 Installing the third DRH onto the third main bracket
(1) Screw
(2) Metal sheet
Step 4 Install the metal sheet for neighboring DRHs, as shown in Figure 7-17.
Figure 7-17 Installing the metal sheet
1. Use an M6 Phillips screwdriver to loosen the screw on the metal sheet farther from the
handle of the first DRH and remove the screw.
2. Use an M6 Phillips screwdriver to loosen the screw on the metal sheet closer to handle of
the first DRH. Then rotate the metal sheet to align the vacant hole in the metal sheet with a hole on the top of the second DRH.
3. Insert the removed screw into the hole on the top of the second DRH and use an M6
torque screwdriver to tighten the screw to 5 N·m (44.25 lbf·in.).
Page 53
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
46
Step 5 Install the second set of DRH mounting brackets above or below the first set of DRH
mounting brackets and maintain a space equal to or greater than 80 mm (3.15 in.) between the two sets of brackets, as shown in Figure 7-18.
Figure 7-18 Installing the second set of DRH mounting brackets
Step 6 Install the fourth DRH onto the fourth main bracket, use an inner hexagon torque screwdriver
to tighten the captive screw into the holes of the attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in
Figure 7-19.
Page 54
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
47
Figure 7-19 Installing the fourth DRH onto the fourth main bracket
----End
7.3 Installing the DRH on U-steel
This section describes the procedure and precautions for installing the DRH on U-steel. A DRH can be installed on U-steel secured on the ground. Each piece of U-steel allows only one DRH to be installed in standard or reverse mode.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Page 55
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
48
Context
(1) U-steel
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Figure 7-20 shows the top view of the DRH installed on U-steel.
When the width of the narrower edges of the U-steel is less than 40 mm (1.57 in.), only the a and b modes are supported.
Figure 7-20 Top view of the DRH
Procedure
Step 1 Determine a position for installing the mounting brackets.
Page 56
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
49
If the DRH must be installed on U-steel secured on the ground, see Figure 7-21 to determine a position.
Figure 7-21 Distance between the mounting brackets and the ground
It is recommended that the mounting brackets be installed at a height of 1200 mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.
Step 2 Install the DRH mounting brackets, as shown in Figure 7-22.
Figure 7-22 Installing the DRH mounting brackets
Verify that the arrows on the mounting brackets are pointing up.
1. Adjust the position of the nut and remove one end of the square-neck bolt from the slot
on the auxiliary bracket.
2. Slide the mounting brackets onto the U-steel horizontally and insert the square-neck bolt
into the slot.
Page 57
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
50
Step 3 Use a 16 mm (0.67 in.) M10 torque wrench to tighten the nuts to 40 N·m (354.03 lbf·in.) so
that the mounting brackets are secured onto the U-steel, as shown in Figure 7-23.
Tighten the nuts on the two square-neck bolts alternatively. After the main and auxiliary brackets are secured properly, measure the spacing between the brackets on both sides and ensure that the spacing is the same on the two sides.
Figure 7-23 Securing the DRH mounting brackets
Step 4 Use an inner hexagon screwdriver to remove the attachment plate from one side of the DRH,
reinstall the attachment plate onto the rear of the DRH, and tighten the four stainless screws to 5 N·m (44.25 lbf·in.), as shown in Figure 7-24.
Page 58
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
51
Figure 7-24 Installing the attachment plate onto the rear of the DRH
Step 5 Install the DRH onto the main bracket, as shown in Figure 7-25.
Figure 7-25 Installing the DRH onto the main bracket
Step 6 Use an inner hexagon screwdriver to tighten the captive screw into the holes on the top of the
attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in Figure7-26.
Page 59
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
52
Figure 7-26 Securing the captive screw into the connection hole
----End
7.4 Installing the DRH on Angle Steel
This section describes the procedure and precautions for installing the DRH on angle steel. A DRH can be installed on angle steel secured on the ground. Each piece of angle steel allows only one DRH to be installed in standard or reverse mode.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Context
Figure 7-27 shows the top view of the DRH installed on angle steel.
Page 60
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
53
(1) Angle steel
Procedure
Step 1 Determine a position for installing the mounting brackets.
Figure 7-27 Top view of the DRH
If the DRH must be installed on angle steel secured on the ground, see Figure 7-28 to determine a position.
Figure 7-28 Distance between the mounting brackets and the ground
It is recommended that the mounting brackets be installed at a height of 1200 mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.
Step 2 Install the DRH mounting brackets, as shown in Figure 7-29.
Page 61
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
54
Figure 7-29 Installing the DRH mounting brackets
Verify that the arrows on the mounting brackets are pointing up.
1. Adjust the position of the nut and remove one end of the square-neck bolt from the slot
on the auxiliary bracket.
2. Slide the mounting brackets onto the angle steel horizontally and insert the square-neck
bolt into the slot.
Step 3 Use a 16 mm (0.67 in.) M10 torque wrench to tighten the nuts to 40 N·m (354.03 lbf·in.) so
that the mounting brackets are secured onto the angle steel, as shown in Figure 7-30.
Tighten the nuts on the two square-neck bolts alternatively. After the main and auxiliary brackets are secured properly, measure the spacing between the brackets on both sides and ensure that the spacing is the same on the two sides.
Page 62
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
55
Figure 7-30 Securing the DRH mounting brackets
Step 4 Use an inner hexagon screwdriver to remove the attachment plate from one side of the DRH,
reinstall the attachment plate onto the rear of the DRH, and tighten the four stainless screws to 5 N·m (44.25 lbf·in.), as shown in Figure 7-31.
Figure 7-31 Installing the attachment plate onto the rear of the DRH
Step 5 Install the DRH onto the main bracket, as shown in Figure 7-32.
Page 63
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
56
Figure 7-32 Installing the DRH onto the main bracket
Step 6 Use an inner hexagon screwdriver to tighten the captive screw into the holes on the top of the
attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in Figure 7-33.
Figure 7-33 Securing the captive screw into the connection hole
----End
Page 64
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
57
7.5 Installing the DRH on a Wall
This section describes the procedure and precautions for installing the DRH on a wall.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Context
The wall on which DRHs are installed must meet the following requirements:
Procedure
Step 1 Disassemble the DRH mounting brackets, as shown in Figure 7-34.
When a single DRH is installed, the wall must be capable of bearing at least four times the weight of the DRH.
Expansion anchor bolts must be tightened to 30 N·m (265.52 lbf·in.) so that the bolts stay secured without damaging the wall.
Page 65
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
58
Figure 7-34 Disassembling the mounting brackets
(1) Main bracket
(2) Square-neck bolt
(3) Pole installation bracket
(4) Auxiliary bracket
(5) Flat washer
(6) Spring washer
(7) Nut
(8) Plastic cap
1. Use an M6 inner hexagon torque screwdriver to remove the four inner hexagon screws
on the pole installation bracket, and remove the main bracket from the pole installation bracket.
2. Use an M10 torque wrench to loosen the nuts on the two square-neck bolts, and remove
the plastic cap, nuts, spring washers, flat washers, square-neck bolts, and pole installation bracket from the auxiliary bracket.
Step 2 Place the pole installation bracket against the installation position, use a level to verify that
the pole installation bracket is placed horizontally, and then mark anchor points with a marker, as shown in Figure 7-35.
Page 66
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
59
Figure 7-35 Marking anchor points
(1) Level
(2) Pole installation bracket
(3) DRH
(1) M10x80 bolt
(2) Nut
(3) Spring washer
(4) Flat washer
(5) Expansion tube
It is recommended that the pole installation bracket be installed at a height of 1200 mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.
Step 3 Drill holes at the anchor points, and then insert expansion anchor bolt assemblies, as shown in
Figure 7-36.
Figure 7-36 Drilling a hole and inserting expansion anchor bolt assemblies
Page 67
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
60
1. Use a hammer drill with a Ф12 bit to drill holes vertically at the marked anchor points.
Ensure that the depth of each hole ranges from 55 mm (2.17 in.) to 60 mm (2.36 in.).
Take proper safety measures to protect your eyes and respiratory tract against the dust before drilling holes.
3. Use a rubber mallet to pound the expansion anchor bolt until it goes all the way into the
hole.
4. Tighten and then loosen the expansion bolt, and remove the M10 bolt, spring washer,
and flat washer in sequence.
After dismantling an expansion anchor bolt, ensure that the top of the expansion tube is on the same level as the wall. Otherwise, the device cannot be installed on the wall evenly and securely.
Step 4 Install the pole installation bracket on the expansion anchor bolts, place the flat washers,
spring washers, and nuts through the expansion anchor bolts in sequence, and then use a 16 mm (0.63 in.) torque socket to tighten the nuts to 30 N·m (265.52 lbf·in.), as shown in Figure
7-37.
Page 68
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
61
Figure 7-37 Installing the pole installation bracket on the expansion anchor bolts
Verify that the arrows on the pole installation bracket are pointing up.
Step 5 Install the main bracket onto the pole installation bracket, and use an inner hexagon
screwdriver to tighten four M6x16 inner hexagon screws to 5 N·m (44.25 lbf·in.) so that the main bracket and pole installation bracket are firmly secured, as shown in Figure 7-38.
Page 69
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
62
Figure 7-38 Installing the main bracket
(1) Main bracket
(2) Pole installation bracket
Step 6 Use an inner hexagon screwdriver to remove the attachment plate from one side of the DRH,
reinstall the attachment plate onto the rear of the DRH, and tighten the four stainless screws to 5 N·m (44.25 lbf·in.), as shown in Figure 7-39.
Figure 7-39 Installing the attachment plate onto the rear of the DRH
Page 70
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
63
Step 7 Install the DRH onto the main bracket, as shown in Figure 7-40.
Figure 7-40 Installing the DRH onto the main bracket
Step 8 Use an inner hexagon screwdriver to tighten the captive screw into the holes on the top of the
attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in Figure 7-41.
Figure 7-41 Securing the captive screw into the connection hole
----End
Page 71
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
64
7.6 Installing a DRH on an IFS06
This section describes the procedure and precautions for installing a DRH on an IFS06.
Prerequisite
The hoist clamp on the main bracket is secured properly.
Do not stand the DRH upright because the RF ports cannot support the weight of the DRH.
Place a foam pad or cardboard under the DRH to protect the DRH housing from damage during the installation.
Context
The upper and lower adjustable beams on an IFS06 can be moved up and down to fit for heights of DRHs.
DRHs can be installed on an IFS06 only when the ambient temperature is higher than or equal to the lowest working temperature of the DRH and at least 5°C (41°F) lower than the highest working temperature of the DRH. In this scenario, the IFS06 supports at least three DRHs. When the ambient temperature is higher than or equal to the lowest working temperature of the DRH and at least 10°C (50°F) lower than the highest working temperature of the DRH, the IFS06 supports a maximum of six DRHs.
Install DRHs in the sequence from bottom to top and from left to right.
This section describes how to install a DRH in height-unrestricted scenarios. The procedure for installing a DRH in height-restricted scenarios is the same as that in height-unrestricted scenarios.
When installing the pole installation bracket, you need to use the M10x50 bolts delivered with the IFS06.
Rubber washers are easily compressed or broken, whereas do not need to be replaced.
Procedure
Step 1 Disassemble the DRH mounting brackets, as shown in Figure 7-42.
Page 72
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
65
Figure 7-42 Disassembling the mounting brackets
(1) Main bracket
(2) Square-neck bolt
(3) Pole installation bracket
(4) Auxiliary bracket
(5) Flat washer
(6) Spring washer
(7) Nut
(8) Plastic cap
1. Use an M6 inner hexagon torque screwdriver to remove the four inner hexagon screws
on the pole installation bracket, and remove the main bracket from the pole installation bracket.
2. Use an M10 torque wrench to loosen the nuts on the two square-neck bolts, and remove
the plastic cap, nuts, spring washers, flat washers, square-neck bolts, and pole installation bracket from the auxiliary bracket.
Step 2 Use the M10x50 bolts delivered with the IFS06 to secure the pole installation bracket to the
IFS06, and then use an M10 torque socket wrench to secure the bolts to 30 N·m (265.52 lbf·in.).
Ensure that the arrows on the pole installation bracket are pointing up.
Height-restricted scenarios
Use one finger to push and remove the rubber plugs on the beam and then install the pole installation bracket, as shown in Figure 7-43.
Page 73
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
66
Figure 7-43 Installing the pole installation bracket in height-restricted scenarios
(1) Spring washer
(2) Rubber washer
Height-unrestricted scenarios
Install the pole installation bracket, as shown in Figure 7-44.
Page 74
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
67
Figure 7-44 Installing the pole installation bracket in height-unrestricted scenarios
(1) Spring washer
(2) Rubber washer
Step 3 Attach the main bracket to the pole installation bracket, and use an inner hexagon screwdriver
to tighten four M6x16 screws to 5 N·m (44.25 lbf·in.) so that the main bracket and pole installation bracket are firmly secured, as shown in Figure 7-45.
Page 75
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
68
Figure 7-45 Installing the main bracket
(1) Main bracket
(2) Pole installation bracket
Step 4 Attach the DRH to the main bracket, and then use an inner hexagon screwdriver to tighten the
captive screw into the holes of the attachment plate and main bracket to 5 N·m (44.25 lbf·in.) so that the attachment plate and main bracket are firmly secured, as shown in Figure 7-46.
Page 76
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
69
Figure 7-46 Installing the DRH onto the main bracket
Step 5 Install the DRHs on the lower level from left to right, as shown in Figure 7-47.
Page 77
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
70
Figure 7-47 Installing DRHs on the lower level
Step 6 Optional: When the ambient temperature is equal to or higher than the lowest operating
temperature of the DRH and at least 10°C (10°F) lower than the highest operating temperature of the DRH, repeat the preceding steps to install the DRHs on the higher level, as shown in
Figure 7-48.
Page 78
DRH Installation Guide
7 Installing the DRH
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
71
Figure 7-48 Installing DRHs on the higher level
----End
Page 79
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
72
8 Installing DRH Cables
This chapter describes the procedure for installing DRH cables.
8.1 Cabling Requirements
Cables must be routed according to the specified cabling requirements to prevent signal interference.
8.2 Cable Connections
This section describes the cable connections for a single DRH and multiple DRHs.
8.3 Installation Process
This section describes the process of installing DRH cables.
8.4 DRH Cable List
This section describes DRH cable connections.
8.5 Installing a DRH PGND Cable
This section describes the procedure for installing a DRH PGND cable.
8.6 Installing a DRH RF Jumper
This section describes the procedure for installing a DRH RF jumper.
8.7 Installing a DRH Alarm Cable
This section describes the procedure for installing a DRH alarm cable.
8.8 Opening the Cover Plate of a DRH Cabling Cavity
This section describes the procedure for opening the cover plate of a DRH cabling cavity.
8.9 Installing a DRH Power Cable
This section describes the procedure for installing a DRH power cable.
8.10 Installing a CPRI Fiber Optic Cable
This section describes the procedure for installing a CPRI fiber optic cable.
8.11 Closing the Cover Plate of a DRH Cabling Cavity
This section describes the procedure for closing the cover plate of a DRH cabling cavity.
Page 80
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
73
8.1 Cabling Requirements
Cables must be routed according to the specified cabling requirements to prevent signal interference.
If a cable listed below is not required, skip the routing requirements of the cable.
General Cabling Requirements
Requirements for Bending Radius
The bending radius of the 7/8'' feeder must be more than 250 mm (9.84 in.), and the bending radius of the 5/4'' feeder must be more than 380 mm (14.96 in.).
The bending radius of the 1/4'' jumper must be more than 35 mm (1.38 in.). The bending radius of the super-flexible 1/2'' jumper must be more than 50 mm (1.97 in.), and the bending radius of the ordinary 1/2'' jumper must be more than 127 mm (5 in.).
The bending radius of the power cable or PGND cable must be at least three times the diameter of the cable.
The bending radius of a fiber optic cable is at least 20 times the diameter of the fiber optic cable, and the minimum bending radius of the breakout cable at each end of the fiber optic cable is 30 mm (1.18 in.).
The bending radius of the signal cable must be at least five times the diameter of the cable.
Requirements for Cable Binding
The same types of cable must be bound together.
Different types of cable must be separately routed with the minimum spacing of 30 mm (1.18 in.) and cannot be entangled.
The cables must be bound tightly and neatly. The sheaths of the cables must not be damaged.
Cable ties are installed in the same direction, and those at the same horizontal line must be in a straight line.
The excess of indoor cable ties is trimmed off, and the excess of outdoor cable ties allows about 5 mm (0.2 in.), without remaining rough edges.
Labels or nameplates must be attached to both ends, joints, or turns of cables after they are installed.
Security Requirements
Cables should be placed away from sharp objects or wall burrs. If these positions are inevitable, protect the cables with protection pipes.
Cables must be routed away from heat sources, or heat-insulation materials are added between cables and heat sources.
Sufficient slack (recommended for about 0.1 m [0.33 ft]) is provided in cables at turns or the position close to a device, facilitating cable and device maintenance.
Outdoor Cabling Requirements
Cables routed outdoors must be led through a pipe when they may be damaged.
AC power cables, transmission cables, and cables buried in the ground must be protected.
Page 81
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
74
If cables at the cabinet bottom need to be routed through a pipe along the ground, lead the pipe into the cabinet base for about 30 mm (1.18 in.) to 50 mm (1.97 in.), not into the cabinet. Block the pipe with waterproof tape or silicon gel, and secure the pipe to the cable hole at the cabinet bottom with metal piece.
If cables at the cabinet bottom need to be routed through a pipe along the metal cable trough, do not lead the pipe into the cabinet base. The cable trough must be sealed and routed through the cable hole at the cabinet bottom.
Cables are secured with cable clips.
Cables are routed neatly along the specified cabling direction and secured with cable clips.
The positions for cable clips are determined onsite. For example, the cable clips for the 7/8" feeder are installed at the spacing of 1.5 m (4.92 ft) to 2 m (6.56 ft) in the same direction, and the cable clips for the power cables are installed at the spacing of 1.5 m (4.92 ft) to 2 m (6.56 ft) in the same direction.
Cable clips must be vertical with cables, and the cables in a cable clip must be parallel.
After routing cables neatly and correctly, tighten the screws on cable clips.
Secure cables on the cable tray, as shown in Figure 8-1.
Figure 8-1 Securing cables on the cable tray
Special Cabling Requirements
Cabling Requirements for Power Cables
Page 82
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
75
Power cables must be installed in the position specified in engineering design documents.
If the length of power cables is insufficient, replace the cables rather than adding connectors or soldering joints to lengthen the cables.
Cables must be routed by only qualified and trained personnel before all preparations are made.
Cables are routed in an untangled and orderly fashion.
Cabling Requirements for PGND Cables
PGND cables for the base station must be connected to the same ground bar.
PGND cables must be buried in the ground or routed indoors. They should not be routed overhead before they are led into the equipment room.
The exterior of the coaxial wire and the shield layer of the shielded cable must have proper electrical contact with the metal surface of the equipment to which they are connected.
PGND cables and signal cables must be installed in an untangled and orderly fashion. A certain distance must be reserved between them to prevent interference from each other.
Fuses or switches must not be installed on the PGND cables.
Other devices must not be used for electrical connections of the PGND cables.
All the metal parts in the housing of the equipment must be reliably connected to the ground terminal.
Cabling Requirements for Fiber Optic Cables
Fiber optic cables must be routed by at least three qualified and trained personnel before all preparations are made.
Fiber optic cables are used within the temperature range of -40°C to 60°C. If the current temperature is out of the range, make protection measures or route the cables again.
Cables are routed in an untangled and orderly fashion.
Do not bind fiber optic cables at turns.
Do not stretch, step on, or place heavy objects on fiber optic cables. Keep the cables away from sharp objects.
When fiber optic cables are routed, the excess of the cables must be coiled around special devices, such as a fiber coiler.
When coiling fiber optic cables, apply even strength. Do not bend the cables with force.
Vacant optical connectors must be covered with dustproof caps.
Fiber optic cables cannot be squeezed by the cabinet door when routed through the cabinet, as shown in Figure 8-2.
Page 83
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
76
Figure 8-2 CPRI fiber optic cables routed through the cabinet
(1) PGND cable
(2) DRH RF jumper
8.2 Cable Connections
This section describes the cable connections for DRHs.
A lower-level DRH obtains power directly from the external power system, but not from an upper-level DRH using a power cable.
Figure 8-3 shows the cable connections for a single DRH.
Figure 8-3 Cable connections for a single DRH
Page 84
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
77
(3) DRH power cable
(4) CPRI fiber optic cable
(5) DRH alarm cable
-
-
(1) PGND cable
(2) DRH RF jumper
(3) DRH power cable
(4) CPRI fiber optic cable
-
-
Figure 8-4 shows the cable connections for DRHs.
Figure 8-4 Cable connections for DRHs
8.3 Installation Process
This section describes the process of installing DRH cables.
Figure 8-5 shows the process of installing DRH cables.
Page 85
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
78
Figure 8-5 Process of installing DRH cables
One End
The Other End
Connector
Installation Position
Connector
Installation Position
OT terminal (M6, 16 mm2 or
0.025 in.2)
Ground terminal on the DRH
OT terminal (M8, 16 mm2 or
0.025 in.2)
Ground terminal on the ground bar
Tool-less female connector (pressfit type)
NEG(-) and RTN(+) ports on the DRH
Depending on the power supply equipment
External power equipment
DB15 waterproof male connector
EXT_ALM port on the DRH
Cord end terminal
External alarm device
8.4 DRH Cable List
This section describes DRH cable connections.
Table 8-1 lists DRH cables.
Table 8-1 DRH cables
Page 86
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
79
One End
The Other End
Connector
Installation Position
Connector
Installation Position
DLC connector
CPRI0 port on the DRH
DLC connector
CPRI port on a board in the DCU or CPRI1 port on the upper-level DRH
CPRI1 port on the DRH
CPRI0 port on the lower-level DRH
DIN male connector
ANT_TX/RX A or ANT_ RXB port on the DRH
DIN male connector
Antenna system
8.5 Installing a DRH PGND Cable
This section describes the procedure for installing a DRH PGND cable.
Context
The cross-sectional area of a DRH PGND cable is 16 mm2 (0.025 in.2). The cable has an M6 OT terminal at one end and an M8 terminal at the other end.
Procedure
Step 1 According to the actual cable route, cut the PGND cable into a proper length to prepare a
DRH PGND cable. Then add an OT terminal at each end of the cable according to the instructions in Assembling the OT Terminal and the Power Cable.
Step 2 Install the DRH PGND cable.
Connect the M6 OT terminal at one end of the PGND cable to the ground terminal at the DRH bottom and the M8 OT terminal at the other end to the external ground bar, as shown in
Figure 8-6.
Page 87
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
80
Figure 8-6 Installing a DRH PGND cable
Crimp OT terminals in correct positions, as shown in Figure 8-7.
Figure 8-7 Correct position of an OT terminal
Step 3 Label the installed cables according to the instructions in Attaching a Cable-Tying Label.
----End
8.6 Installing a DRH RF Jumper
This section describes the procedure for installing a DRH RF jumper.
Procedure
Step 1 Connect the DIN male connector at one end of the DRH RF jumper to the ANT port on the
DRH, and use a torque wrench to tighten the connector to 25 N·m (221.27 lbf·in.), as shown in Figure 8-8.
Page 88
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
81
Figure 8-8 Installing a DRH RF jumper
On AC-powered electric railways, such as high speed railways, when leaky cables are connected to DRHs installed in tunnels, high-voltage-resistance DC blocks must be installed between DRH RF jumpers and the leaky cables to protect the DRHs against damage.
Step 2 Link the other end of the RF jumper to the external antenna system. Step 3 Waterproof the connectors of the RF jumper by referring to Figure 8-9.
Page 89
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
82
Figure 8-9 Waterproofing a connector of the RF jumper
(1) Waterproof tape
(2) PVC insulation tape
Before wrapping waterproof tape, stretch the tape evenly until the length of the tape becomes twice its original length.
Do not stretch the PVC insulation tape when wrapping the PVC insulation tape.
Wrap each layer of tape around the connector tightly and neatly, and ensure that each layer of tape overlaps more than 50% of the preceding layer. Ensure that neighboring layers are stuck to each other.
Ensure that the adhesive surface of the tape overlaps the lower layer.
When cutting off the cable ties, reserve a redundant length of 3 mm (0.12 in.) to 5 mm (0.2 in.).
1. Wrap three layers of waterproof tape on the connector, first from bottom up, then from
top down, and finally from bottom up. Start wrapping the connector at a position 50 mm (1.97 in.) away below the bottom of the connector to the top of the connector, first from bottom up, then from top down, and finally from bottom up. Cut off the redundant tape after three layers are wrapped. Wrap each layer of tape around the connector tightly.
2. Wrap three layers of PVC insulation tape. Start the wrapping at a position 30 mm (1.18
in.) away below the bottom of the waterproof tape to the top of the connector, first from bottom up, then from top down, and finally from bottom up. Cut off the redundant tape after three layers are wrapped. Wrap each layer of tape around the connector tightly.
3. Start binding cable ties to the cable at a position 3 mm (0.12 in.) to 5 mm (0.2 in.) away
from one end of the PVC insulation tape.
Step 4 Check the dustproof caps on antenna connectors. In outdoor scenarios, dustproof caps must be
waterproofed, as shown in Figure 8-10.
Page 90
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
83
(1) Dustproof cap
(2) Waterproof tape
(3) PVC insulation tape
Do not remove dustproof caps from vacant antenna connectors.
Figure 8-10 Waterproofing a dustproof cap
Before wrapping waterproof tape, stretch the tape evenly until the length of the tape becomes twice its original length.
Do not stretch the PVC insulation tape when wrapping the PVC insulation tape.
Wrap each layer of tape around the connector tightly and neatly, and ensure that each layer of tape overlaps more than 50% of the preceding layer. Ensure that neighboring layers are stuck to each other.
Ensure that the adhesive surface of the tape overlaps the lower layer.
When cutting off the cable ties, reserve a redundant length of 3 mm (0.12 in.) to 5 mm (0.2 in.).
1. Verify that dustproof caps are not removed.
2. Wrap three layers of waterproof tape on the connector, first from bottom up, then from
top down, and finally from bottom up. Wrap each connector with three layers of waterproof tape, from bottom up, then from top down, and finally from bottom up. Do not cut the tape until all the three layers of the tape are already wrapped. Cut off the redundant tape after three layers are wrapped. Wrap each layer of tape around the connector tightly.
3. Wrap three layers of PVC insulation tape. Wrap each connector with three layers of
waterproof tape, from bottom up, then from top down, and finally from bottom up. Do not cut the tape until all the three layers of the tape are already wrapped. Cut off the redundant tape after three layers are wrapped. Wrap each layer of tape around the connector tightly.
4. Start binding cable ties to the cable at a position 3 mm (0.12 in.) to 5 mm (0.2 in.) away
from one end of the PVC insulation tape.
Step 5 Route the cables according to the instructions in 8.1 Cabling Requirements, and then use
cable ties to bind the cables.
Step 6 Label the installed cables according to the instructions in Attaching a Sign Plate Label.
Page 91
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
84
----End
8.7 Installing a DRH Alarm Cable
This section describes the procedure for installing a DRH alarm cable.
Procedure
Step 1 Use an M3 Phillips screwdriver to loosen the screws on the dustproof cap on the EXT_ALM
port and remove the dustproof cap.
Step 2 Connect the waterproof DB15 connector at one end of the DRH alarm cable to the
EXT_ALM port on the DRH, and connect the eight cord end terminals at the other end to external alarm devices, as shown in Figure 8-11.
Figure 8-11 Installing a DRH alarm cable
Step 3 Use an M3 Phillips screwdriver to tighten the posts on both sides of the waterproof DB15
male connector to 0.4 N·m (3.54 lbf·in.).
Step 4 Route the cables according to the instructions in 8.1 Cabling Requirements, and then use
cable ties to bind the cables.
Step 5 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End
Page 92
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
85
8.8 Opening the Cover Plate of a DRH Cabling Cavity
(1) Cover plate
(2) Cabling cavity
(3) Clip
(4) Cable trough for the power cable
(5) Waterproof block
(6) Cable trough for the fiber optic cable
This section describes the procedure for opening the cover plate of a DRH cabling cavity.
Procedure
Step 1 Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic damage to the boards, modules, or electronic components.
Step 2 Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the DRH
cabling cavity, and open the cover plate, as shown in Figure 8-12.
Figure 8-12 Opening the cover plate of the DRH cabling cavity
Step 3 Loosen the screws on the clip, and open the clip, as shown Figure 8-13.
Open the clip only for the associated cable.
Page 93
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
86
Figure 8-13 Opening clips
Step 4 Remove the waterproof block.
Remove only the waterproof blocks for the cables to be installed.
----End
8.9 Installing a DRH Power Cable
This section describes the procedure for installing a DRH power cable.
Prerequisite
An easy power receptacle (pressfit type) connector is added to the DRH power cable on the DRH side. For details, see 11.1 Adding a Tool-Less Female Connector (Pressfit Type)
to the DRH Power Cable on the DRH Side.
Add a connector or OT terminals to the DRH power cable on the power device side. For details, see the DRH Installation Guide.
Context
There are two types of DRH power cables in terms of cross-sectional areas: 3.3 mm2 (0.005 in.2) (12 AWG) complying with North American standards and 4 mm2 (0.006 in.2) complying with European standards.
Table 8-2 describes the power cable connections.
Page 94
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
87
Table 8-2 Power cable connections
Cabl e
Powe r Devic e
One End
The Other End
Re mar ks
Connector
Instal latio n Positi on
Connector
Installation Position
DRH power cable
DCD U-11 B
Tool-less female connector (pressfit type)
Power port on a DRH
Tool-less female connector (pressfit type)
One of the LOAD0 to LOAD5 ports on the DCDU-11B
Blac k
EPU
One of the DRH0 to DRH5 ports on the EPU
Procedure
Step 1 Connect the tool-less female connector (pressfit type) at one end of the DRH power cable to
When installing the DRH power cable, connect the DRH power cable first to the DRH and then to the power device. Operations in the reverse sequence may cause damage to the components and injury of human bodies.
the power supply socket on the DRH, as shown in Figure 8-14.
Page 95
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
88
Figure 8-14 Installing a DRH power cable
Ensure that the exposed shield layer of the power cable is properly tightened using the clip.
Step 2 Connect the tool-less female connector (pressfit type) at the other end of the DRH power
cable to the corresponding position on the power device.
A DCDU-11B can supply power to a maximum of six DRHs. The DRH power cables are connected to the LOAD0 to LOAD5 terminals on the DCDU-11B.
An EPU can supply power to a maximum of six DRHs. The DRH power cables are connected to the DRH0 to DRH5 ports on the EPU.
When the DRH power cable is connected to the EPU, the blue core wire in the tool-less female connector (pressfit type) is connected to the left part of a port on the EPU, and the black/brown core wire is connected to the right part of the port on the EPU.
Step 3 Route the cables according to the instructions in 8.1 Cabling Requirements, and then use
cable ties to bind the cables.
Step 4 Label the installed cables according to the instructions in Attaching a Cable-Tying Label.
----End
8.10 Installing a CPRI Fiber Optic Cable
This section describes the procedure for installing a CPRI fiber optic cable.
Page 96
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
89
Prerequisite
Context
Before the installation, single-mode optical modules can be distinguished from multi-mode optical modules in either of the following ways:
SM and MM labels on an optical module: SM indicates a single-mode optical module, and MM indicates a multi-mode optical module.
Color of the puller on an optical module: Blue indicates a single-mode optical module, and black or gray indicates a multi-mode optical module.
The optical modules to be installed must match CPRI rates.
A CPRI fiber optic cable transmits CPRI signals between a DCU and a DRH.
For details about CPRI fiber optic cable connections, see section "CPRI Cable Connections" in the DCU Hardware Description or DRH Hardware Description.
Procedure
Step 1 Lower the pullers of two optical modules, insert one optical module into the CPRI0 port on
the DRH and the other optical module into the CPRI port on the DCU, and raise the pullers, as shown in Figure 8-15.
Figure 8-15 Installing an optical module
The performance of an optical module that is exposed to the air for more than 20 minutes may be abnormal. Therefore, you must insert an fiber optic cable into an unpacked optical module within 20 minutes.
Page 97
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
90
Step 2 Connect the end labeled 1A and 1B of the fiber optic cable to the optical module on the DRH
side, as shown in Figure 8-16.
Figure 8-16 Installing a CPRI fiber optic cable
To avoid any damage to fiber optic cables, the cables connected to the DRH must be installed according to the installation process. For details about the installation process, see
8.3 Installation Process.
Step 3 Connect the end labeled 2A and 2B of the fiber optic cable to the optical module on the DCU
side.
Step 4 Route the cables according to the instructions in 8.1 Cabling Requirements, and then use
cable ties to bind the cables.
Step 5 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End
Page 98
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
91
8.11 Closing the Cover Plate of a DRH Cabling Cavity
This section describes the procedure for closing the cover plate of a DRH cabling cavity.
Procedure
Step 1 Close the clips for the installed cables. Use a torque screwdriver to tighten the screws on each
clip to 1.4 N·m (12.39 lbf·in.), as shown in Figure 8-17.
Ensure that the exposed shield layer of the power cable is properly tightened using the clip.
Figure 8-17 Closing clips
Step 2 Insert waterproof blocks into vacant cable troughs in the cabling cavity, as shown in Figure
8-18.
Ensure that cables and waterproof blocks are properly inserted into troughs.
Page 99
DRH Installation Guide
8 Installing DRH Cables
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
92
Figure 8-18 Correct placement of waterproof blocks
Step 3 Close the cover plate of the DRH cabling cavity. Use an M5 torque screwdriver to partially
tighten the screws on the cover plate in the sequence shown in Figure 8-19. Then tighten the screws to 2 N·m (17.7 lbf·in.) in the same sequence.
Figure 8-19 Closing the cover plate of a DRH cabling cavity
Step 4 Take off the ESD gloves, and pack up all the tools.
----End
Page 100
DRH Installation Guide
9 Checking the DRH Hardware Installation
Issue Draft A ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd..
93
9 Checking the DRH Hardware Installation
SN
Item
1
The position for each device conforms to the engineering drawing and meets the space requirement. Sufficient space is reserved for equipment maintenance.
2
The DRH is securely installed.
3
The cover plate is securely installed on the DRH cabling cavity.
4
Waterproof blocks are securely installed in vacant cable troughs of the DRH cabling cavity, and the cover plate for the cabling cavity is securely installed. In addition, vacant RF ports are covered with dustproof caps and the caps are tightened.
5
There are no connectors or joints on each power cable or PGND cable.
6
The terminals at two ends of each power cable or PGND cable are securely soldered or crimped.
7
None of power cables and PGND cables can be short-circuited or reversely connected. In addition, these cables are not damaged or broken.
8
Power cables and PGND cables are separately bound from other cables.
9
The protection grounding of the DRH and the surge protection grounding of the building share one group of ground conductors.
10
The connectors of each signal cable are intact and securely linked, and these cables are not damaged or broken.
11
Labels are correct, legible, and complete at both ends of each cable, feeder, and jumper.
After a DRH is installed, check the hardware installation.
Table 9-1 provides the checklist for the DRH hardware installation.
Table 9-1 Checklist for the DRH hardware installation