No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website:http://e.huawei.com
Issue 16 (2015-08-26)Huawei Proprietary and Confidential
CloudEngine 7800&6800&5800 Series Switches
Hardware DescriptionAbout This Document
About This Document
Intended Audience
This document describes hardware components of the CE7800&6800&5800 series switches,
including the chassis, power modules, fan modules, cables, and optical modules. You can find
useful information about CE7800&6800&5800 series switches hardware components from this
document.
This document is intended for:
lNetwork planning engineers
lHardware installation engineers
lCommissioning engineers
lOn-site maintenance engineers
lSystem maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
SymbolDescription
Indicates an imminently hazardous situation
which, if not avoided, will result in death or
serious injury.
Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury.
Issue 16 (2015-08-26)Huawei Proprietary and Confidential
CloudEngine 7800&6800&5800 Series Switches
Hardware Description
SymbolDescription
Command Conventions
About This Document
Indicates a potentially hazardous situation
which, if not avoided, could result in
equipment damage, data loss, performance
deterioration, or unanticipated results.
NOTICE is used to address practices not
related to personal injury.
Calls attention to important information, best
practices and tips.
NOTE is used to address information not
related to personal injury, equipment damage,
and environment deterioration.
The command conventions that may be found in this document are defined as follows.
ConventionDescription
BoldfaceThe keywords of a command line are in boldface.
ItalicCommand arguments are in italics.
[ ]Items (keywords or arguments) in brackets [ ] are optional.
{ x | y | ... }Optional items are grouped in braces and separated by
vertical bars. One item is selected.
[ x | y | ... ]Optional items are grouped in brackets and separated by
vertical bars. One item is selected or no item is selected.
{ x | y | ... }
[ x | y | ... ]
&<1-n>The parameter before the & sign can be repeated 1 to n times.
#A line starting with the # sign is comments.
*
*
Optional items are grouped in braces and separated by
vertical bars. A minimum of one item or a maximum of all
items can be selected.
Optional items are grouped in brackets and separated by
vertical bars. Several items or no item can be selected.
Declaration
This manual is only a reference for you to configure your devices. The contents in the manual,
such as command line syntax, and command outputs, are based on the device conditions in the
Issue 16 (2015-08-26)Huawei Proprietary and Confidential
CloudEngine 7800&6800&5800 Series Switches
Hardware Description
lab. The manual provides instructions for general scenarios, but do not cover all usage scenarios
of all product models. The contents in the manual may be different from your actual device
situations due to the differences in software versions, models, and configuration files. The
manual will not list every possible difference. You should configure your devices according to
actual situations.
The specifications provided in this manual are tested in lab environment (for example, the tested
device has been installed with a certain type of boards or only one protocol is run on the device).
Results may differ from the listed specifications when you attempt to obtain the maximum values
with multiple functions enabled on the device.
Change History
Changes between document issues are cumulative. The latest document issue contains all the
changes made in earlier issues.
Issue 16 (2015-08-26)
About This Document
This version has the following updates:
The following information is modified:
l2 Chassis
l3 Power Module
l4 Fan Module
Issue 15 (2015-06-10)
This version has the following updates:
The following information is modified:
l2.3 Appearance and Structure
l6.2 SFP/SFP+ Modules
Issue 14 (2015-05-30)
This version has the following updates:
The following information is added:
lCE6810-32T16S4Q-LI
lCE6810-24S2Q-LI
lCE6850-48T6Q-HI
lCE6851-48S6Q-HI
lCE6850U-48S6Q-HI
lCE6850U-24S2Q-HI
lCE5855-48T4S2Q-EI
lCE5855-24T4S2Q-EI
l150 W AC Power Module (ES0W2PSA0150)
Issue 16 (2015-08-26)Huawei Proprietary and Confidential
CloudEngine 7800&6800&5800 Series Switches
Hardware Description
Contents
Contents
About This Document.....................................................................................................................ii
1 Version Support for Components..............................................................................................1
1.1 Components Available in V100R001C00......................................................................................................................2
1.2 Components Available in V100R002C00......................................................................................................................3
1.3 Components Available in V100R003C00......................................................................................................................5
1.4 Components Available in V100R003C10......................................................................................................................7
1.5 Components Available in V100R005C00......................................................................................................................9
1.6 Components Available in V100R005C10....................................................................................................................12
2.2 Version Mapping..........................................................................................................................................................19
2.3 Appearance and Structure.............................................................................................................................................20
3 Power Module............................................................................................................................105
3.1 150 W AC Power Module (PAC-150WA).................................................................................................................106
3.2 150 W AC Power Module (ES0W2PSA0150)...........................................................................................................110
3.3 350 W AC Power Module..........................................................................................................................................113
3.4 350 W DC Power Module..........................................................................................................................................118
3.5 600 W AC Power Module..........................................................................................................................................123
3.6 600 W AC&240 V DC Power Module.......................................................................................................................128
3.7 600 W High-Voltage DC Power Module...................................................................................................................134
4 Fan Module.................................................................................................................................139
4.1 FAN-40EA Series Fan Modules.................................................................................................................................140
4.2 FAN-40SB Series Fan Modules.................................................................................................................................143
4.3 FAN-40HA Series Fan Modules................................................................................................................................147
4.4 FAN-040A Series Fan Modules.................................................................................................................................151
4.5 FAN-060A Series Fan Modules.................................................................................................................................155
CloudEngine 7800&6800&5800 Series Switches
Hardware DescriptionContents
5.1 AC Power Cable.........................................................................................................................................................161
5.2 DC Power Cable.........................................................................................................................................................162
5.3 380 V High-Voltage DC Power Cable.......................................................................................................................164
CloudEngine 7800&6800&5800 Series Switches
Hardware Description1 Version Support for Components
1 Version Support for Components
About This Chapter
NOTE
The availability of device models and modules described in this document will be specified in product
change notices (PCNs). For details, contact the product manager of Huawei local office.
The versions mentioned in this document refer to the software versions released for the
CE7800&6800&5800 series switches.
1.1 Components Available in V100R001C00
1.2 Components Available in V100R002C00
1.3 Components Available in V100R003C00
1.4 Components Available in V100R003C10
1.5 Components Available in V100R005C00
1.6 Components Available in V100R005C10
Issue 16 (2015-08-26)Huawei Proprietary and Confidential
CloudEngine 7800&6800&5800 Series Switches
Hardware Description2 Chassis
2.1 Naming Conventions
Figure 2-1 shows the CE7800&6800&5800 series switches naming conventions.
Figure 2-1 CE7800&6800&5800 series switches naming conventions
Table 2-1 describes the CE7800&6800&5800 series switches naming conventions.
Table 2-1 CE7800&6800&5800 series switches naming conventions
FieldMeaning
ACloudEngine series data center switches
l CE78: CE7800 series
l CE68: CE6800 series
l CE58: CE5800 series
BProduct model category:
l 10: basic model
l 50: advanced model
CSpecial function flag. This flag is not present if the product does not provide special
functions.
U: The product supports the unified port function.
DNumber and type of downlink interfaces:
l T: GE/10GBase-T electrical interfaces
l S: GE/10GE SFP+ optical interfaces
l Q: quad small form-factor pluggable plus (QSFP+) optical interfaces
ENumber and types of uplink interfaces:
l T: GE/10GBase-T electrical interfaces
l S: GE/10GE SFP+ optical interfaces
l Q: QSFP+ optical interfaces
NOTE
This field is not present in the product name if the product has only fixed interfaces and the uplink
and downlink interfaces are the same type or if the product supports flexible service units.
Issue 16 (2015-08-26)Huawei Proprietary and Confidential