HQ EL-EPM02FHQ User Manual

1
EL-EPM02FHQ
MANUAL (p. 2)
Energy meter French version
MODE D’EMPLOI (p. 7)
Compteur électrique – Version Française
EN
Corrections EL-EPM02FHQ_A5.indd 1 2009.6.10 6:03:04 PM
2
English
Introduction:
Plug-In (French/Belgium version) Mains Power and Energy Monitor. Measures voltage (V), Ampere (A), Watts (W), Volt-Ampere(VA), Hertz (Hz) and power factor (PF). Ideal to check how much power your appliances are consuming.
Operation:
FUNC
SET
Display
UP
Master clear
General features:
1) Display current clock
2) Display line voltage
3) Display line current
4) Display line power
5) Display and memory peak line power
6) Display and memory accumulative total electric quantity
7) Display and memory total on time and total electric charge
8) Display and memory total on time and total electric charge of price1
9) Display and memory total on time and total electric charge of price2
10) Display line frequency
11) Display power factor
12) Adjustable max. overload current, max. overload warning
13) Adjustable price / kWh
11 combinations of day or blocks of days available as follows: MO/ TU/ WE/ TH/ FR/ SA/ SU/ MO, TU, WE, TH, FR/ MO, TU, WE, TH, FR, SA/ SA, SU/ MO, TU, WE, TH, FR, SA, SU
The data base:
Press FUNC button the data displays as follows:
VOLTvac AMP WATT MAX WATT KWh TOTAL PRICE; TOTAL ON TIME PRICE1 PRICE2
Corrections EL-EPM02FHQ_A5.indd 2 2009.6.10 6:03:04 PM
3
1) The meter will display current clock and line voltage, frequency, if plug in socket after insert battery without any operation
2) Press FUNC button once and release, the meter will display current clock and line current, power factor
3) Press FUNC button once again and release, the meter will display current clock and real power, power factor
4) Press FUNC button once again and release, the meter will display max. line power and the appear time of max. line power, power factor. Press and hold FUNC button for 5 seconds will clear max. line power display during this state
5) Press FUNC button once again and release, the meter will display current clock and accumulative power factor
6) Press FUNC button once again and release, the meter will display total on time and total electrical charge
7) Press FUNC button once again and release, the meter will display total on time of price 1 and total electrical charge of price 1
8) Press FUNC button once again and release, the meter will display total on time of price 2 and total electric charge of price 2
9) Press FUNC button once again and release, the meter will come back to display current time and line voltage. Press and hold FUNC button for 5 seconds to clear accumulative total electric quantity and total electric charge during display state of total electric charge or total electric charge of price 1 or total electric charge of price 2
10) LCD display when total electric quantity, total electric charge overow, the OVER
will ash at the same time
Setting current clock:
1) Press FUNC button until the CLOCK displays in LCD
2) Press SET button once time, the WEEK DAY will ash at the same time, the clock
change to SET mode, you can set the current clock
3) Press UP button to set the WEEK DAY
4) Press SET button once time again and release, the HOUR will ash the WEEK DAY will stop ashing and keep display
5) Press UP button to set the HOUR
6) Press SET button once time again and release, the MINUTE will ash, the HOUR will stop ashing and keep display
7) Press UP button to set the MINUTE
8) Press SET button once time again and release, the time come back to CLOCK display mode
9) Press UP button during the CLOCK display state, change 12-24 hour mode. To reset
incorrect time, repeat all above steps. After nish setting, plug the meter into a regular
230/240V power outlet, plug in an appliance that you want to use and turn the mains power on. Now the meter begins to measure the consumption of the appliance and detect the equipment that uses too much electricity at once
Corrections EL-EPM02FHQ_A5.indd 3 2009.6.10 6:03:04 PM
4
Setting price of cost/kWh & over load current:
Press and hold FUNC button for 5 seconds during display state of voltage or current or power.
Setting price 1:
1) Press SET button once and release, SET display, the rst digital COST.kWh ash, press
UP button to set it
2) Press SET button once and release, the second COST/kWh ash, press UP button to set it
3) Press SET button once and release, the third COST/kWh ash, press UP button to set it
4) Press SET button once and release, the fourth COST/kWh ash, press UP button to set it
5) Press SET button once and release, the radix point COST/kWh ash, press UP button to
set it
6) Press SET button once and release, the weekday ash, press UP button to set it
7) Press SET button once and release, the hour of ON TIME ash, press UP button to set it
Setting price 2:
1) Press FUNC button once and release after nish Setting price 1, setting price 2. repeat
above steps
Setting OVER LOAD current data:
Press FUNC button once and release after nish setting price 2
1) Press SET button once and release, SET and AMP display, the rst digital MAX. LOAD ash, press UP button to set it
2) Press SET button once and release, the second digital MAX.LOAD ash, press UP
button to set it
3) Press SET button once and release, the third MAX. LOAD ash, press UP button to set it
4) Press SET button once and release, the fourth MAX. LOAD ash, press UP button to set it
The OVER LOAD WARNING will ash when load overtop the setting data. The button function
will failure. You must draw out the appliance or set the OVER LOAD data again.