HP SAN Array 1000 User Manual

QuickSpecs

Overview

hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
HP StorageWorks Modular SAN Array 1000
The msa1000 offers the following key features
The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1” universal disk drives in a single 4U rackmount cabinet. More storage can be easily deployed with the addition of up to two StorageWorks 4314 Enclosures for a maximum storage capacity of 6 TB when using the new 146 GB drives. The msa1000 provides the latest 2 Gb Fibre Channel technology to the hosts. Besides the single port 2 Gb Fibre Channel I/O module that comes standard, there is an optional 3-port 2 Gb Fibre Channel hub that also fits inside – an ideal low cost solution for simple 2-node clustering. There is also a newly introduced 8-port switch that mounts internally, featuring a low cost per port option that saves rack space. The msa1000 provides Ultra3 SCSI connections to the hard drives and uses the HP Universal 1” Ultra2, Ultra3, and/or Ultra320 drives. By utilizing SCSI drives, the msa1000 lowers the total cost of ownership and extends the customer’s hardware investments into the future.
An alternative firmware version, installed in place of the standard version, now enables support for OpenVMS and Tru64 UNIX. A copy of this alternative firmware ships with the msa1000 and is also downloadable at no charge from the HP msa1000 Web site. It replaces the existing firmware that ships with the MSA1000. Included with the firmware will be instructions on the procedure to upgrade the firmware in either a Tru64 UNIX or an OpenVMS environment
High performance controller(s) built on DAS to SAN {DtS} architecture for maximum investment protection
4U rackmount design combining both the controller and disk shelf
2 Gb Fibre Channel host connections
Ultra3 SCSI connections to drives
Support for HP Ultra2, Ultra3, and Ultra320 Universal 1” Drives
Scaleable from 3 to 42 drives via HP StorageWorks 4200/4300 Enclosures
Support for 1 Gb and 2 Gb Fibre Channel fabrics
What’s new
Supported Alpha servers
Multiple clusters and/or single server access to an individual msa1000.
Support for concurrent access by servers with OpenVMS and Tru64 UNIX operating systems
Redundancy (if present) retained while expanding number of drives or enlarging LUNs
New 3-port embedded hub or 8-port switch option
Ability to add an additional storage drive enclosure (42/4300) to a msa1000 without power cycling unit
Support for larger and/or faster drives allowing total capacity to scale to 6 TB
DS10, DS10L, DS20E, DS25
ES40, ES45, ES47, ES80
GS80, GS160, GS320, GS1280
DA-11621 Canada — Version 2 — April 15, 2003 1
QuickSpecs

MSA1000 Highlights

hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
High Levels of Performance, Scalability, and Functionality
Performance – The msa1000 and its components have been designed using the latest industry standard 2 Gb interconnects and Fibre Channel technology. Performance tests indicate a data transmission rate of over 30, 000 IOPS and bandwidth of up to 200 MB per second. (Single msa1000 Controller)
Modular Chassis – The modular design of the msa1000 cabinet supports up to fourteen 1” Universal hard drives, redundant controllers, 2 Gb embedded fabric switches or hubs, fans and power supplies in a 4U rackmount cabinet.
Scalability – The msa1000 is easily expanded. The msa1000 cabinet scales to 2.0 TB, using fourteen, 146 GB, 1” HP Universal hard drives. By simply adding additional StorageWorks 4200/4300 Enclosures (two enclosures max), the msa1000 scales to 6.0 TB, using forty-two, 146 GB, 1” HP Universal hard drives – all within 10U of rack space.
msa Hub 2/3 – The optional msa Hub 2/3, to be installed within the msa1000, offers 2 Gb performance. With two ports accessible by the user, the msa hub 2/3 is the ideal interconnect for low-cost 2-node clustering or simple attaching two servers. A second msa hub 2/3 can be installed for redundancy. This hub ships with two SFPs included.
msa SAN switch 2/8 – The optional msa SAN switch 2/8 can also be installed within the msa1000. With seven ports accessible by the user, the msa SAN switch 2/8 is the ideal interconnect for cost effective multiple clusters or nodes or connection to other hp SAN switches from the hp interconnect family of switches. A second msa SAN switch 2/8 can be installed for redundancy. This switch ships with four SFPs included.
Hot Plug Expansion and Replacement Support – The msa1000 supports hot plug expansion and replacement of hard drives, redundant controllers, fabric switches or hubs for simple, fast installation and maintenance. Fans and power supplies are also hot plug replaceable.
Advanced Data Guarding (RAID ADG) Fault Tolerance – This is the highest level of fault tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.
Low Total Cost of Ownership
The modular and scalable design of the msa1000 provides an extremely flexibly platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, cache, fabric switches and storage enclosures can easily be added, as your storage needs change.
Fabric Support for 1 Gb and 2 Gb Infrastructure – The msa1000 supports both 1 Gb and 2 Gb Fibre Channel fabrics to ensure that your investment in 1 Gb infrastructure is protected.
Optional embedded interconnects – The msa SAN switch 2/8 or the msa hub 2/3 require no rack space as they are installed in the msa1000’s chassis. This not only saves valuable rack space (up to 2U saved) but also eliminates some of the cabling needed with external interconnects.
Universal Hard Drive – Since the msa1000 supports HP Universal 1” Ultra2, Ultra3 and Ultra320 drives, cost is minimized as you add new drives
Configuration Command Line Interface (CLI) – A connection between a standard ANSI
terminal or terminal emulator and the msa1000 is required to use the command line interface (CLI) to configure and manage the msa1000. A custom serial cable, part number 259992-001, is required for this connection and ships with the MSA1000. CLI commands are documented in the HP StorageWorks Modular SAN Array 1000 User Guide.
Management −−−− msa1000 events are logged in the OpenVMS or Tru64 UNIX error log and can be monitored with HP Analyze or other error log analysis tools.
DA-11621 Canada — Version 2 — April 15, 2003 2
QuickSpecs
A
A
A
A
A
A
A
A
A
A

Models

hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
HP StorageWorks Modular SAN Array 1000 For Alpha Server Systems w/ OpenVMS and Tru64 UNIX
msa1000, with 256MB cache 201723-B22/
3R-A4328-A
msa1000 Controller, with 256MB cache 218231-B22/
3R-A4330-A
256 MB Cache Module for Controller 254786-B21/
3R-A3954-A
msa Fibre Channel I/O Module 218960-B21/
3R-A2969-A
msa SAN Switch 2/8 (integrated) 288247-B21/
3R-A4289-A
msa HUB 2/8 (integrated) 286763-B21/
3R-A3907-A
FCA2354 Host Adapter (Open VMS/Tru64 UNIX) 261329-B21/
DS-KGPSA-D
2 Gb SFP SW Transceiver Kit 221470-B21/
3R-A2973-A
HP StorageWorks Enclosure Model 4314R 190209-001/
DS-SL13R-A
HP StorageWorks Dual bus Enclosure Model 4354R 190211-001/
DS-SL13R-B
DA-11621 Canada — Version 2 — April 15, 2003 3
QuickSpecs
specific for Tru64 UNIX and OpenVMS only

MSA1000 Components

With the following components, your storage capacity and performance can be scaled to new levels
Modular SAN Array 1000
The 4U cabinet houses up to fourteen 1” Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives. Each msa1000 includes the following standard components: (1) msa1000 Controller, (1) msa Fibre Channel I/O Module with a single SFP, dual hot pluggable fans/power supplies and power cables, (2) 3’ VHDCI to VHDCI SCSI cables to connect expansion enclosures, documentation and a CD Kit containing firmware upgrade code for Tru64 and OpenVMS and a support software CD.
The modular design of the msa1000 makes it possible to add redundant controllers, redundant single port Fibre Channel I/O Modules, 3-port hub, or msa SAN switch 2/8 and storage expansion enclosures.
hp StorageWork s
modular SAN array 1000
msa1000 Controller
The msa1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256 MB read/write battery-backed cache (expandable to 512 MB per controller). One msa1000 Controller is included with the msa1000; a redundant msa1000Controller is an option.
Key Features
msa1000 Controller Management Features
Fault Tolerance
Fault Recovery
Redundant controller support with mirrored cache
Fabric, Private Loop & Public Loop Support
Auto Negotiated F, FL & L Port Login
RAID 0, 1, 1+0, 5 and ADG
2 Gb/1 Gb Frequency Agile
Primary & Secondary Inter-Controller Link (ICL)
configurable with Command Line Interface (CLI)
Online RAID Level Migration: allows for online post-configuration change to
RAID level without destroying data or volume information.
Online Capacity Expansion: lets you add storage to an operational msa1000—reducing expensive server downtime.
Global Online Spare: reduces the risk of data loss by facilitating automatic rebuilds after a drive failure
Several fault tolerant configurations, which keep data available and servers running while drives are being replaced, are supported including:
Advanced Data Guarding (RAID ADG): Allocates the equivalence of two parity drives across multiple drives and allows simultaneous write operations.
Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows simultaneous write operations.
Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file.
Minimizes downtime, reconstructs data, and f acilitates a quick recovery from drive failure
Online Spares: If a failure occurs, recovery begins with an online spare and data is reconstructed automatically. Multiple online spares can be assigned per array and used across multiple arrays. It is also possible to assign different online spares across different arrays.
Array Accelerator: Onboard, battery-backed cache memory protects data in the event of a power failure. In the unlikely event of a controller failure, the battery-backed cache will save critical user dat a for up to three days
msa Fibre Channel I/O Module
DA-11621 Canada — Version 2 — April 15, 2003 4
Provides a single 2 Gb Fibre Channel connection per controller from the host side into the msa1000. The msa Fibre Channel I/O Module includes one 2 Gb, Short Wave, Small-Form-Factor-Pluggable Transceiver (SFP). A second msa Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used.
QuickSpecs
MSA1000 Components
hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
msa Hub 2/3
msa SAN switch 2/8
The HP StorageWorks msa Hub 2/3 is a low-cost interconnect designed for clustering or low cost, high speed attachment of two servers to the msa1000, an entry-level storage area network (SAN) solution. The msa Hub 2/3 is a 3-port Fibre Channel Arbitrated Loop hub that is mounted on a blade that easily installs inside the msa1000 storage unit, saving valuable rack space. Two of these hubs may be installed for redundancy within the msa1000. The msa Hub 2/3 is not cascadable.
The hub presents the user with two SFP ports for simple direct attachment to two single or clustered servers without having to purchase an external interconnect device. It offers the most cost-effective solution for a user to enable a clustered server environment.
high-performance: supports msa1000 with a 2 Gb interconnect capable of 200 MB/s speed
low cost: supports the entry-level SAN array with the most cost effective option for 2-node clustering
compact: imbeds in the msa1000, replacing the I/O module, saving valuable rack space
complete: comes with two SW SFPs – no need for further investment
The hp StorageWorks msa SAN switch 2/8 ia a new optional switch embedded on a blade, for mounting internal to an msa1000. The msa SAN Switch 2/8 offers low price per port and full scalability, doing so while taking zero rack space, even in a redundant configuration. It ships with four SFPs installed. Because of its’ low cost per port it is the most cost effective method of enabling the larger SAN. It is interoperable with the hp line of SAN interconnect family of FC switches.
eight 2 Gb ports: 1 to controller, 7 user accessible
product ships with 4 SFPs installed
no E-port restriction, accepts all optional software
interoperates with external SAN Switch 2 Gb switches
configuration and management methodology common with SAN Switch product line, same methods as
installed base of 30,000+ HP SAN Switches
2 Gb Small Form Factor Pluggable (SFP) SW Transceiver Kit
Multi-Mode Fibre Channel Cables
2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot plug into 2 Gb infrastructure components such as 2 Gb Fabric Switches. StorageWorks 2 Gb SFP SW Transceivers support distances up to 300 metres at 2 Gb and 500 metres at 1 Gb using multi-mode fiber optic cable.
Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic interference. HP offers cables to connect the msa1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC to LC cables are used when connecting the msa1000 to other 2 Gb Fibre Channel components because both connections will utilize small form factor transceivers. LC to SC cables are used when connecting the msa1000 to 1 Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers.
SOFTWARE COMPONENTS
Command Line Interface (CLI)
OS Support Tru64 UNIX Support
The command line interface (CLI) is used to configure and manage the MSA1000. Additionally, the CLI can be used to display system information and status. See the HP StorageWorks Modular SAN Array 1000 User Guide for more information on the CLI commands
OpenVMS Support
Tru64 UNIX v5.1A with PK4 and NHD6
Tru64 UNIX v5.1B with IPK
OpenVMS v7.3-1 with TIMA (ECO) Kit
OpenVMS v7.2-2 with TIMA (ECO) Kit
OpenVMS v7.3 with TIMA (ECO) Kit
DA-11621 Canada — Version 2 — April 15, 2003 5
QuickSpecs
specific for Tru64 UNIX and OpenVMS only

Service & Support, CarePaq and Warranty Information

hp StorageWork s
modular SAN array 1000
Storage Service Packages
Warranty
Service & Support, CarePaq and Warranty Information
The Storage Services Packaging takes the existing storage product along with the existing services and creates a package of the storage hardware and appropriate services. The increased level of support provides for a higher level of storage system availability for the customer. The package includes 24x7 support with a 4-hour response for 3 years as well as installation and startup service.
Three-year Limited Warranty for msa1000s, Fibre Channel Cables and SFP Transceivers; 3 years parts exchange; 1 year labour; 1 year on-site; next business day response. Options for the msa1000 carry their own warranty. Refer to HP's Limited Warranty Statement for further details.
Software Product Services
Hardware Product Services
Installation and Startup Services
Warranty Upgrade Options
HP warrants only that the Software media will be free of physical defects for a period of ninety (90) days from delivery.
Upgrades to the 90 day media defect warranty are available as CarePaq services. These services are available to upgrade the warranty to (1 or 3) full year of 9 hours by 5 days (or 24x7) software advisory and remedial software telephone support, new version license rights, and media and documentation distribution service.
Installation services
On-site maintenance (includes warranty support)
Response time upgrades during the warranty period
Post-warranty coverage
RAID setup and performance consulting via statement of work
Migration service consulting via statement of work
The Installation and Startup Service package provides installation and configuration of HP StorageWorks products. Major categories of work could include:
Pre-installation consulting and planning
Hardware installation, configuration and verification
RAID array configuration and initialization
Installation, configuration and verification of StorageWorks software
Service tools installed, configured and verified
Customer orientation
Response – Upgrade on-site response from next business day to same
day 4 hours
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
Duration – Select duration of coverage for a period of 1, 3, or 5 years
DA-11621 Canada — Version 2 — April 15, 2003 6
Loading...
+ 11 hidden pages