HP SAN Array 1000 User Manual

QuickSpecs

Overview

hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
HP StorageWorks Modular SAN Array 1000
The msa1000 offers the following key features
The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1” universal disk drives in a single 4U rackmount cabinet. More storage can be easily deployed with the addition of up to two StorageWorks 4314 Enclosures for a maximum storage capacity of 6 TB when using the new 146 GB drives. The msa1000 provides the latest 2 Gb Fibre Channel technology to the hosts. Besides the single port 2 Gb Fibre Channel I/O module that comes standard, there is an optional 3-port 2 Gb Fibre Channel hub that also fits inside – an ideal low cost solution for simple 2-node clustering. There is also a newly introduced 8-port switch that mounts internally, featuring a low cost per port option that saves rack space. The msa1000 provides Ultra3 SCSI connections to the hard drives and uses the HP Universal 1” Ultra2, Ultra3, and/or Ultra320 drives. By utilizing SCSI drives, the msa1000 lowers the total cost of ownership and extends the customer’s hardware investments into the future.
An alternative firmware version, installed in place of the standard version, now enables support for OpenVMS and Tru64 UNIX. A copy of this alternative firmware ships with the msa1000 and is also downloadable at no charge from the HP msa1000 Web site. It replaces the existing firmware that ships with the MSA1000. Included with the firmware will be instructions on the procedure to upgrade the firmware in either a Tru64 UNIX or an OpenVMS environment
High performance controller(s) built on DAS to SAN {DtS} architecture for maximum investment protection
4U rackmount design combining both the controller and disk shelf
2 Gb Fibre Channel host connections
Ultra3 SCSI connections to drives
Support for HP Ultra2, Ultra3, and Ultra320 Universal 1” Drives
Scaleable from 3 to 42 drives via HP StorageWorks 4200/4300 Enclosures
Support for 1 Gb and 2 Gb Fibre Channel fabrics
What’s new
Supported Alpha servers
Multiple clusters and/or single server access to an individual msa1000.
Support for concurrent access by servers with OpenVMS and Tru64 UNIX operating systems
Redundancy (if present) retained while expanding number of drives or enlarging LUNs
New 3-port embedded hub or 8-port switch option
Ability to add an additional storage drive enclosure (42/4300) to a msa1000 without power cycling unit
Support for larger and/or faster drives allowing total capacity to scale to 6 TB
DS10, DS10L, DS20E, DS25
ES40, ES45, ES47, ES80
GS80, GS160, GS320, GS1280
DA-11621 Canada — Version 2 — April 15, 2003 1
QuickSpecs

MSA1000 Highlights

hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
High Levels of Performance, Scalability, and Functionality
Performance – The msa1000 and its components have been designed using the latest industry standard 2 Gb interconnects and Fibre Channel technology. Performance tests indicate a data transmission rate of over 30, 000 IOPS and bandwidth of up to 200 MB per second. (Single msa1000 Controller)
Modular Chassis – The modular design of the msa1000 cabinet supports up to fourteen 1” Universal hard drives, redundant controllers, 2 Gb embedded fabric switches or hubs, fans and power supplies in a 4U rackmount cabinet.
Scalability – The msa1000 is easily expanded. The msa1000 cabinet scales to 2.0 TB, using fourteen, 146 GB, 1” HP Universal hard drives. By simply adding additional StorageWorks 4200/4300 Enclosures (two enclosures max), the msa1000 scales to 6.0 TB, using forty-two, 146 GB, 1” HP Universal hard drives – all within 10U of rack space.
msa Hub 2/3 – The optional msa Hub 2/3, to be installed within the msa1000, offers 2 Gb performance. With two ports accessible by the user, the msa hub 2/3 is the ideal interconnect for low-cost 2-node clustering or simple attaching two servers. A second msa hub 2/3 can be installed for redundancy. This hub ships with two SFPs included.
msa SAN switch 2/8 – The optional msa SAN switch 2/8 can also be installed within the msa1000. With seven ports accessible by the user, the msa SAN switch 2/8 is the ideal interconnect for cost effective multiple clusters or nodes or connection to other hp SAN switches from the hp interconnect family of switches. A second msa SAN switch 2/8 can be installed for redundancy. This switch ships with four SFPs included.
Hot Plug Expansion and Replacement Support – The msa1000 supports hot plug expansion and replacement of hard drives, redundant controllers, fabric switches or hubs for simple, fast installation and maintenance. Fans and power supplies are also hot plug replaceable.
Advanced Data Guarding (RAID ADG) Fault Tolerance – This is the highest level of fault tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.
Low Total Cost of Ownership
The modular and scalable design of the msa1000 provides an extremely flexibly platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, cache, fabric switches and storage enclosures can easily be added, as your storage needs change.
Fabric Support for 1 Gb and 2 Gb Infrastructure – The msa1000 supports both 1 Gb and 2 Gb Fibre Channel fabrics to ensure that your investment in 1 Gb infrastructure is protected.
Optional embedded interconnects – The msa SAN switch 2/8 or the msa hub 2/3 require no rack space as they are installed in the msa1000’s chassis. This not only saves valuable rack space (up to 2U saved) but also eliminates some of the cabling needed with external interconnects.
Universal Hard Drive – Since the msa1000 supports HP Universal 1” Ultra2, Ultra3 and Ultra320 drives, cost is minimized as you add new drives
Configuration Command Line Interface (CLI) – A connection between a standard ANSI
terminal or terminal emulator and the msa1000 is required to use the command line interface (CLI) to configure and manage the msa1000. A custom serial cable, part number 259992-001, is required for this connection and ships with the MSA1000. CLI commands are documented in the HP StorageWorks Modular SAN Array 1000 User Guide.
Management −−−− msa1000 events are logged in the OpenVMS or Tru64 UNIX error log and can be monitored with HP Analyze or other error log analysis tools.
DA-11621 Canada — Version 2 — April 15, 2003 2
QuickSpecs
A
A
A
A
A
A
A
A
A
A

Models

hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
HP StorageWorks Modular SAN Array 1000 For Alpha Server Systems w/ OpenVMS and Tru64 UNIX
msa1000, with 256MB cache 201723-B22/
3R-A4328-A
msa1000 Controller, with 256MB cache 218231-B22/
3R-A4330-A
256 MB Cache Module for Controller 254786-B21/
3R-A3954-A
msa Fibre Channel I/O Module 218960-B21/
3R-A2969-A
msa SAN Switch 2/8 (integrated) 288247-B21/
3R-A4289-A
msa HUB 2/8 (integrated) 286763-B21/
3R-A3907-A
FCA2354 Host Adapter (Open VMS/Tru64 UNIX) 261329-B21/
DS-KGPSA-D
2 Gb SFP SW Transceiver Kit 221470-B21/
3R-A2973-A
HP StorageWorks Enclosure Model 4314R 190209-001/
DS-SL13R-A
HP StorageWorks Dual bus Enclosure Model 4354R 190211-001/
DS-SL13R-B
DA-11621 Canada — Version 2 — April 15, 2003 3
QuickSpecs
specific for Tru64 UNIX and OpenVMS only

MSA1000 Components

With the following components, your storage capacity and performance can be scaled to new levels
Modular SAN Array 1000
The 4U cabinet houses up to fourteen 1” Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives. Each msa1000 includes the following standard components: (1) msa1000 Controller, (1) msa Fibre Channel I/O Module with a single SFP, dual hot pluggable fans/power supplies and power cables, (2) 3’ VHDCI to VHDCI SCSI cables to connect expansion enclosures, documentation and a CD Kit containing firmware upgrade code for Tru64 and OpenVMS and a support software CD.
The modular design of the msa1000 makes it possible to add redundant controllers, redundant single port Fibre Channel I/O Modules, 3-port hub, or msa SAN switch 2/8 and storage expansion enclosures.
hp StorageWork s
modular SAN array 1000
msa1000 Controller
The msa1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256 MB read/write battery-backed cache (expandable to 512 MB per controller). One msa1000 Controller is included with the msa1000; a redundant msa1000Controller is an option.
Key Features
msa1000 Controller Management Features
Fault Tolerance
Fault Recovery
Redundant controller support with mirrored cache
Fabric, Private Loop & Public Loop Support
Auto Negotiated F, FL & L Port Login
RAID 0, 1, 1+0, 5 and ADG
2 Gb/1 Gb Frequency Agile
Primary & Secondary Inter-Controller Link (ICL)
configurable with Command Line Interface (CLI)
Online RAID Level Migration: allows for online post-configuration change to
RAID level without destroying data or volume information.
Online Capacity Expansion: lets you add storage to an operational msa1000—reducing expensive server downtime.
Global Online Spare: reduces the risk of data loss by facilitating automatic rebuilds after a drive failure
Several fault tolerant configurations, which keep data available and servers running while drives are being replaced, are supported including:
Advanced Data Guarding (RAID ADG): Allocates the equivalence of two parity drives across multiple drives and allows simultaneous write operations.
Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows simultaneous write operations.
Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file.
Minimizes downtime, reconstructs data, and f acilitates a quick recovery from drive failure
Online Spares: If a failure occurs, recovery begins with an online spare and data is reconstructed automatically. Multiple online spares can be assigned per array and used across multiple arrays. It is also possible to assign different online spares across different arrays.
Array Accelerator: Onboard, battery-backed cache memory protects data in the event of a power failure. In the unlikely event of a controller failure, the battery-backed cache will save critical user dat a for up to three days
msa Fibre Channel I/O Module
DA-11621 Canada — Version 2 — April 15, 2003 4
Provides a single 2 Gb Fibre Channel connection per controller from the host side into the msa1000. The msa Fibre Channel I/O Module includes one 2 Gb, Short Wave, Small-Form-Factor-Pluggable Transceiver (SFP). A second msa Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used.
QuickSpecs
MSA1000 Components
hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
msa Hub 2/3
msa SAN switch 2/8
The HP StorageWorks msa Hub 2/3 is a low-cost interconnect designed for clustering or low cost, high speed attachment of two servers to the msa1000, an entry-level storage area network (SAN) solution. The msa Hub 2/3 is a 3-port Fibre Channel Arbitrated Loop hub that is mounted on a blade that easily installs inside the msa1000 storage unit, saving valuable rack space. Two of these hubs may be installed for redundancy within the msa1000. The msa Hub 2/3 is not cascadable.
The hub presents the user with two SFP ports for simple direct attachment to two single or clustered servers without having to purchase an external interconnect device. It offers the most cost-effective solution for a user to enable a clustered server environment.
high-performance: supports msa1000 with a 2 Gb interconnect capable of 200 MB/s speed
low cost: supports the entry-level SAN array with the most cost effective option for 2-node clustering
compact: imbeds in the msa1000, replacing the I/O module, saving valuable rack space
complete: comes with two SW SFPs – no need for further investment
The hp StorageWorks msa SAN switch 2/8 ia a new optional switch embedded on a blade, for mounting internal to an msa1000. The msa SAN Switch 2/8 offers low price per port and full scalability, doing so while taking zero rack space, even in a redundant configuration. It ships with four SFPs installed. Because of its’ low cost per port it is the most cost effective method of enabling the larger SAN. It is interoperable with the hp line of SAN interconnect family of FC switches.
eight 2 Gb ports: 1 to controller, 7 user accessible
product ships with 4 SFPs installed
no E-port restriction, accepts all optional software
interoperates with external SAN Switch 2 Gb switches
configuration and management methodology common with SAN Switch product line, same methods as
installed base of 30,000+ HP SAN Switches
2 Gb Small Form Factor Pluggable (SFP) SW Transceiver Kit
Multi-Mode Fibre Channel Cables
2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot plug into 2 Gb infrastructure components such as 2 Gb Fabric Switches. StorageWorks 2 Gb SFP SW Transceivers support distances up to 300 metres at 2 Gb and 500 metres at 1 Gb using multi-mode fiber optic cable.
Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic interference. HP offers cables to connect the msa1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC to LC cables are used when connecting the msa1000 to other 2 Gb Fibre Channel components because both connections will utilize small form factor transceivers. LC to SC cables are used when connecting the msa1000 to 1 Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers.
SOFTWARE COMPONENTS
Command Line Interface (CLI)
OS Support Tru64 UNIX Support
The command line interface (CLI) is used to configure and manage the MSA1000. Additionally, the CLI can be used to display system information and status. See the HP StorageWorks Modular SAN Array 1000 User Guide for more information on the CLI commands
OpenVMS Support
Tru64 UNIX v5.1A with PK4 and NHD6
Tru64 UNIX v5.1B with IPK
OpenVMS v7.3-1 with TIMA (ECO) Kit
OpenVMS v7.2-2 with TIMA (ECO) Kit
OpenVMS v7.3 with TIMA (ECO) Kit
DA-11621 Canada — Version 2 — April 15, 2003 5
QuickSpecs
specific for Tru64 UNIX and OpenVMS only

Service & Support, CarePaq and Warranty Information

hp StorageWork s
modular SAN array 1000
Storage Service Packages
Warranty
Service & Support, CarePaq and Warranty Information
The Storage Services Packaging takes the existing storage product along with the existing services and creates a package of the storage hardware and appropriate services. The increased level of support provides for a higher level of storage system availability for the customer. The package includes 24x7 support with a 4-hour response for 3 years as well as installation and startup service.
Three-year Limited Warranty for msa1000s, Fibre Channel Cables and SFP Transceivers; 3 years parts exchange; 1 year labour; 1 year on-site; next business day response. Options for the msa1000 carry their own warranty. Refer to HP's Limited Warranty Statement for further details.
Software Product Services
Hardware Product Services
Installation and Startup Services
Warranty Upgrade Options
HP warrants only that the Software media will be free of physical defects for a period of ninety (90) days from delivery.
Upgrades to the 90 day media defect warranty are available as CarePaq services. These services are available to upgrade the warranty to (1 or 3) full year of 9 hours by 5 days (or 24x7) software advisory and remedial software telephone support, new version license rights, and media and documentation distribution service.
Installation services
On-site maintenance (includes warranty support)
Response time upgrades during the warranty period
Post-warranty coverage
RAID setup and performance consulting via statement of work
Migration service consulting via statement of work
The Installation and Startup Service package provides installation and configuration of HP StorageWorks products. Major categories of work could include:
Pre-installation consulting and planning
Hardware installation, configuration and verification
RAID array configuration and initialization
Installation, configuration and verification of StorageWorks software
Service tools installed, configured and verified
Customer orientation
Response – Upgrade on-site response from next business day to same
day 4 hours
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
Duration – Select duration of coverage for a period of 1, 3, or 5 years
DA-11621 Canada — Version 2 — April 15, 2003 6
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Service & Support, CarePaq and Warranty Information
hp StorageWork s
modular SAN array 1000
CarePaq Information
Sample part numbers:
9x5, Next Business Day, On-Site Coverage, 3 years FM-FCXHW-36
103840-002
9x5, 4-Hour Response, On-Site Coverage, 3 years FM-FC4HR-36
402165-002
24x7, 4-Hour Response, On-Site Coverage, 3 years FM-FC724-36
402164-002
9x5, Next Business Day, On-Site Coverage, 5 years FM-FCXHW-60
170183-002
9x5, 4-Hour Response, On-Site Coverage, 5 years FM-FC4HR-60
170185-002
24x7, 4-Hour Response, On-Site Coverage, 5 years FM-FC724-60
170187-002
Hardware Installation FM-FCINS-IN
402162-002
CarePaq is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage.
CarePaq is not available for less than the product’s warranty duration.
CarePaq is available for sale anytime during the warranty period for most products, but the commencement
date will be the same a s the Warranty Start Date (delive ry date to end user customer) . Proof of purchase may be required.
CarePaq services are prepaid.
NOTE: For additional CarePaq (hardware & software) information, as well as orderable part numbers, please
refer to the URL listed below:
English: http://www.compaq.ca/English/productinfo/storage/storageworks.htm French: http://www.compaq.ca/Francais/Produits/stockage/Storageworksf.htm
DA-11621 Canada — Version 2 — April 15, 2003 7
QuickSpecs

Configuration Information

STEP 1 – ORDER REQUIRED ITEMS
HP StorageWorks Modular SAN Array 1000 201723-B22
Includes
hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
(1) msa1000 Controller with 256 MB cache
(1) MSA Fibre Channel I/O Module with 2 Gb SFP SW Transceiver
Redundant Hot Pluggable Power Supply/blower assemblies
Universal Rackmounting Kit
msa1000 Support CD & Documentation
(2) Power cables
(2) 3-ft VHDCI to VHDCI SCSI cables
NOTE: Fibre Channel cables are ordered separately.
DA-11621 Canada — Version 2 — April 15, 2003 8
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Configuration Information
STEP 2 – SELECT OPTIONAL NON-REDUNDANT MSA1000 SYSTEM OPTIONS
msa SAN Switch 2/8 (integrated) (Includes four 2Gb SFPs) 288247-B21 msa Hub 2/3 (integrated) (Includes two 2 Gb SFP transceivers) 286763-B21
NOTE: The msa Hub 2/3 has two external Fibre Channel ports, both of which already
have 2 Gb transceivers installed. The msa SAN switch 2/8 has seven external ports, four of which have transceivers installed.
modular SAN array 1000
hp StorageWork s
DA-11621 Canada — Version 2 — April 15, 2003 9
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Configuration Information
STEP 3 – CHOOSE REDUNDANT MSA1000 SYSTEM OPTIONS
Redundant Configuration
msa1000 Controller 218231-B22
NOTE: Redundant configurations require two Host Adapters per server, an additional
controller for each server. Mixing of the msa Fibre Channel I/O Modular and the msa Hub 2/3 is not supported. When configuring the msa1000 for redundant controllers use either two msa Fibre Channel I/O Modules, two msa SAN switch 2/8s, or two msa Hub 2/3s.
hp StorageWork s
modular SAN array 1000
msa Fibre Channel I/O Module (Includes 2 Gb SFP transceiver) 218960-B21 msa Hub 2/3 (integrated) (Includes two 2Gb SFP transceivers) 286763-B21 msa SAN Switch 2/8 (integrated) (Includes four 2Gb SFP transceivers) 288247-B21
DA-11621 Canada — Version 2 — April 15, 2003 10
hp StorageWork s
modular SAN array 1000
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Configuration Information
STEP 4 – CHOOSE SUPPORTED OPTION S FOR 2 GB OR 1 GB INFRASTRUCTURE
2 Gb Fibre Channel Transceiver
(SFP)
2 Gb SFP SW Transceiver Kit 221470-B21
2 Gb Fibre Channel Fabric “Infrastructure” family of switches
NOTE: “Infrastructure” switches above are interoperable only with HP StorageWorks
MSA SAN Switch 2/8, SAN Switch 2/8EL, 2/16, 2/32, core 2/64 products and all Power Pak models. They are also interoperable with designated discontinued 1
Gb SAN Switch models.
HP StorageWorks core 2/64 PowerPak HP StorageWorks core 2/64 HP StorageWorks SAN Switch 2/32 PowerPak HP StorageWorks SAN Switch 2/32 HP StorageWorks SAN Switch 2/16 PowerPak HP StorageWorks SAN Switch 2/16 HP StorageWorks SAN Switch 2/16-EL HP StorageWorks SAN Switch 2/8 PowerPak HP StorageWorks SAN Switch 2/8-EL HP StorageWorks MSA SAN Switch 2/8 (Includes four 2 Gb SFP transceivers) Fabric Watch for 8 and 16 port switches ISL Trunking kit for 8 and 16 port switches Advanced Performance Monitor for 8 and 16 port switches Quick Loop for 8 and 16 port switches Remote Switch for 8 and 16 port switches Extended Fabric for 8 and 16 port switches HP StorageWorks PowerPak Bundle for 2 Gb Brocade Based 8 and 16 port
Switches(Trunking, Perf Monitor, remote switch, fabric watch, extended fabric) HP Storageworks 2/8-EL Upgrade license
Optional Rack mount kit for SAN Switch 2/8-EL and SAN Switch 2/16 Remote Switch for HP StorageWorks 2/64 ISL trunking for HP StorageWorks 2/64
Extended fabric for HP StorageWorks 2/64
332178-B21 254508-B21 333764-B21 240603-B21 322119-B21 322118-B21 283056-B21 322121-B21 322120-B21 288247-B21 324504-B21 324506-B21 324507-B21 324508-B21 325891-B21 324505-B21 325892-B21
325888-B21 331148-B21 330883-B21 325887-B21
325886-B21
2 Gb Fibre Channel Fabric Switches, “High Availability” family of switches
2 Gb Fibre Channel Integrated Hub
DA-11621 Canada — Version 2 — April 15, 2003 11
NOTE: “High Availability” switches above are interoperable only with HP StorageWorks
Director 2/140. Director 2/64, Edge Switch 2/32, Edge Switch 2/24, and the
discontinued Edge Switch 2/16 products.
HP StorageWorks Director 2/140 (64-ports active) 316094-B21 HP StorageWorks director 2/64 286809-B21 HP StorageWorks edge switch 2/32 (16 active ports) 286810-B21 8-FlexPort upgrade for edge 2/32 302660-B21 HP StorageWorks Edge switch 2/24 (8 ports active) 8-FlexPort upgrade for edge 2/24
MSA Hub 2/3 (integrated option, comes complete with two SFPs) 286763-B21
316095-B21
316096--B21
hp StorageWork s
modular SAN array 1000
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Configuration Information
STEP 4 – CHOOSE SUPPORTED OPTION S FOR 2 GB OR 1 GB INFRASTRUCTURE (continued)
2 Gb Fibre Channel HBAs
FCA2354 Host Adapter (Tru64 UNIX, OpenVMS) 261329-B21
Fibre Channel Cables for 2 Gb Infrastructure
Fibre Channel Cables for 1 Gb Fabric Switches and Hub
Use 2 Gb Fibre Channel cables when connecting the msa Fibre Channel I/O Module or the msa Fabric Switch 6 to FCA2101 HBA(s)
2 m LC-LC Multi-Mode Fibre Channel Cable 5 m LC-LC Multi-Mode Fibre Channel Cable 15 m LC-LC Multi-Mode Fibre Channel Cable 30 m LC-LC Multi-Mode Fibre Channel Cable 50 m LC-LC Multi-Mode Fibre Channel Cable
Use 1 Gb Fibre Channel cables when connecting the msa Fibre Channel I/O Module and FCA2354 HBA(s) to 1 Gb fabric switches or hubs.
2 m LC-SC Multi-Mode Fibre Channel Cable 5 m LC-SC Multi-Mode Fibre Channel Cable 15 m LC-SC Multi-Mode Fibre Channel Cable 30 m LC-SC Multi-Mode Fibre Channel Cable 50 m LC-SC Multi-Mode Fibre Channel Cable
221692-B21 221692-B22 221692-B23 221692-B26 221692-B27
221691-B21 221691-B22 221691-B23 221691-B26 221691-B27
STEP 5 – CHOOSE HARD DRIVES & STORAGEWORKS ENCLOSURES
Hard Drives 36.4 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″) 286713-B22
72.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″) 286714-B22
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1) 286716-B22
18.2 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″) 286775-B22
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″) 286776-B22
72.8 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″) 286778-B22
*NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3
speeds. NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive
Compatibility table located at: http://www.hp.com/.
NOTE: This Web site is available in English only.
DA-11621 Canada — Version 2 — April 15, 2003 12
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Configuration Information
STEP 5 – CHOOSE HARD DRIVES & STORAGEWORKS ENCLOSURES (continued)
modular SAN array 1000
StorageWorks Enclosures
STEP 6 – CHOOSE RACK OPTIONS
The msa1000 cabinet holds fourteen 1” Universal Drives. Add one StorageWorks Enclosure to increase capacity up to 28 drives. Add two HP StorageWorks Enclosures to increase capacity up to the maximum of 42 drives.
HP StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the msa1000)
HP StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the msa1000)
9142 Rack 9136 Rack 9122 Rack 9842 Rack 10647 (47U) rack 10642 (42U) rack 10636 (36U) rack 10622 (22U) rack H9A10 Cab H9A15 Cab
hp StorageWork s
190209-001
190211-001
120663-B21, -B22, -B23 120664-B21, -B22, -B23 120665-B21, -B22, -B23
222192-B21
245160-B21, -B23 245161-B21, -B22, -B23 245162-B21, -B22, -B23 245163-B21, -B22, -B23
H9A10-XX H9A15-XX
DA-11621 Canada — Version 2 — April 15, 2003 13
QuickSpecs
Configuration Information
CONFI GURATION EXAMPLES
Quantity Description Part Number
1 HP StorageWorks Modular SAN Array 1000 201723-B22 1 msa1000 Controller 218231-B22 2
4 Host Adapter 261329-B21 4 2 m LC-LC Multi-Mode Fibre Channel Cable 221692-B21
14 36.4 GB Pluggable Ultra320 Universal Hard Drive, 15K 286776-B21
Quantity Description Part Number
1 HP StorageWorks Modular SAN Array 1000 201723-B22 1 msa1000 Controller 218231-B22 2 256 MB Cache Modules for Controller (one additional for each controller) 254786-B21 2 msa SAN Switch 2/8 (Includes four 2Gb SFP transceivers) 288247-B21 8 Host Adapter (appropriate model for operating system) 8 2 m LC-LC Multi-Mode Fibre Channel Cable 221692-B21 2 StorageWorks Enclosure Model 4314R 190209-001
42
msa Hub 2/3 286763-B21
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
Two Node Redundant Cluster Solution
4 Host, 6TB, Redundant SAN Solution
286716-B22
DA-11621 Canada — Version 2 — April 15, 2003 14
QuickSpecs

Technical Specifications

MODULAR SAN ARRAY 1000
LED Indicators on Front (3)
LED Indicators for Drive Modules (3)
LED Indicators on Rear Panel
(4)
Interface
Maximum Number of Drives
Temperature Range
Relative Humidity
Input Power Requiremen ts
Heat Dissipation (max)
msa1000 Cabinet
Shipping Packaging
Power Fault detected in one or more sub- systems Fault in Enclosure Management Drive Access (centre) Online (left) Drive Failure (right) Power Supply/Blower Assembly Fault (1) EMU (3) Power, A bus, B bus Ultra3 SCSI to Hard Drives 2 Gb Fibre Channel to Hosts Fourteen, 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (msa1000 Cabinet); expandable to 42 using
two additional StorageWorks 4200/4300 Enclosures Operating Shipping
NOTE: Derated 1°C per 1,000 feet of elevation to 10,000 ft.
Operating 10% to 90% Non-operating Up to 95% Rated Input Voltage 100 to 240 VAC Rated Input Frequency 50 to 60 Hz Rated Input Current 6 A Max Input Power (max) 549 W* 1876 Btu/hr*
* Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration.
4U Rack Form Factor Dimensions (H x W x D) 6.9 x 19 x 20.5 in/17.5 x 48.3 x 52.1 cm Weight Net 55 to 85 lb/24.95 to 38.56 kg Dimensions (L x W x D) 28.5 x 14.81 x 33.13 in/72.4 x 37.6 x 84.1 cm Weight Gross 75 to 105 lb/34.02 to 47.63 kg
hp StorageWork s
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
50° to 95°F/10° to 35°C –22° to 122°F/–30° to 50°C
DA-11621 Canada — Version 2 — April 15, 2003 15
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Technical Specifications
MODULAR SAN ARRAY 1000 CONTROLLER
User Interface
Electrical Interface Protocol Support SCSI Ports Drives Supported Maximum Capacity Logical Drives RAID Support
Cache Memory
Cache Batteries Upgradeable Firmware Disk Drive and Enclosure
Protocol Support Packaging
Controller Display with Status Indicators (2) and Push Buttons (4) Status Indicators on front of Controller (16)
LVD (Low Voltage Differential) Wide Ultra3 SCSI (160 MB/s per channel) 4-channel: 2 external/2 Internal Up to 42 drives
6.0 TB (42 drives x 146 GB) Up to 32 logical drives RAID ADG (Advanced Data Guarding) RAID 5 (Distributed Data Guarding) RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping) Up to 512 MB Read/Write (256-MB modules). Added cache size must match original and if a second controller is
employed, it too must have equally configured cache. ECC protection, battery-backed, and removable Standard, starting November 19, 2002: 256 MB cache memory (single module)
Up to three days of redundant battery life, removable for easy replacement 2 MB flashable ROM HP Ultra 320, Ultra3, and Ultra2 SCSI 1-inch Universal drives
Dimensions (L x W x D) 17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm Weight Gross 6 lb/2.72 kg
hp StorageWork s
modular SAN array 1000
MODULAR SAN ARRAY FIBRE CHANNEL I/O MODULE
Connector Type Number of Fibre Channel Ports Bandwidth Operation Modes Protocols Supported Packaging
LC One 2 Gb Fibre Channel Port using removable Small-Form-Factor-Pluggable Transceiver (SFP) 200 MB/s Fibre Channel Class 2 and 3 connectionless service Fibre Channel Dimensions (L x W x D) 17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm Weight Gross 6 lb/2.72 kg
FCA2354 HOST ADAPTER
Connector Type Protocol Data Transfer Method Maximum Transfer Rate Packaging
DA-11621 Canada — Version 2 — April 15, 2003 16
LC SCSI, IP 64-bit/66 MHz PCI 200 MB/s Dimensions (L x W x D) 11 x 8.5 x 3 in/27.9 x 21.6 x 7.6 cm Weight Gross 1 lb/0.45 kg
hp StorageWork s
modular SAN array 1000
QuickSpecs
specific for Tru64 UNIX and OpenVMS only
Technical Specifications
MUL TI-MODE FIB RE CHANNEL CABLES KITS
Cable Type Available Cable Lengths Packaging
© 2003 Compaq Canada Corp. (an HP Company) All rights reserved. Printed in Canada. Hewlett-Packard, the Hewlett-Packard logo, CarePaq, Open VMS, ProLiant, StorageWorks and Tru64 are trademarks of Hewlett-Packard Company in the
U.S. and/or other countries. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. All other product names mentioned herein may be trademarks of their respective companies.
Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided “as is” without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.
LC-LC (2 Gb to 2 Gb connections) and LC-SC (2 Gb to 1 Gb connections) 50 Micron multi-mode fibre
6.5 ft, 16.4 ft, and 49.2 ft/2 m, 5 m, and 15 m Dimensions (L x W x D) 11.5 x 9 x 1.5 in/29.2 x 22.8 x 3.8 cm Weight Gross 0.75 to 1 lb/0.34 to 0.45 kg
DA-11621 Canada — Version 2 — April 15, 2003 17
Loading...