HEWLETT-PACKARD COMPANY MAKES NO WARRANTY
OF ANY KIND WITH REGARD TO THIS MATERIAL,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not
be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing,
performance, or use of this material.
The information contained herein is subject to change
without notice. The only warranties for HP products and
services are set forth in the express warranty statements
accompanying such products and services. Nothing herein
should be construed as constituting an additional warranty.
HP shall not be liable for technical or editorial errors or
omissions contained herein.
Hewlett-Packard assumes no responsibility for the use or
reliability of its software on equipment that is not furnished
by Hewlett-Packard.
See the Customer Support/Warranty booklet included with
the product.
A copy of the specific warranty terms applicable to your
Hewlett-Packard products and replacement parts can be
obtained from your HP Sales and Service Office or
authorized dealer.
Safety
Before installing and operating these products, please read
the “Installation Precautions” in chapter 2, “Installing the
Switch 5300xl Series”, and the safety statements in
appendix C, “Safety and Regulatory Statements”.
Hewlett-Packard Company
8000 Foothills Boulevard, m/s 5552
Roseville, California 95747-5552
The ProCurve Switch 5300xl Series include the Switch 5304xl and its bundles,
the Switch 5348xl and the Switch 5332xl-Gigabit, and the Switch 5308xl and
its bundles, the Switch 5372xl and the Switch 5348xl-Gigabit. They are multiport modular switches that provide Layer 3 routing features, and that feature
low latency for high-speed networking.
This chapter describes your Switch 5300xl Series including:
■Front and back of the switches
■Features
■Switch operation overview
Switch 5304xl, Switch 5348xl and the Switch 5304xl-32G. The Switch
5304xl is available as an open 4-slot chassis (J4850A), as the Switch 5348xl
bundle (J4849B) with two 24-port 10/100-TX xl Modules pre-installed, and as
the Switch 5304xl-32G (J8166A) with two 16-port 100/1000-T xl Modules preinstalled.
1
Introducing the ProCurve
Switch 5300xl Series
ProCurve Switch 5304xl
(J4850A)
ProCurve
Switch 5348xl
bundle (J4849B)
with two
10/100-TX xl Modules
preinstalled
hp procurve
switch 5304xl
J4850A
hp procurve
switch 5304xl
J4850A
procurve
xl module
J4820B
Reset
Console
Console
Clear
Self
Test
ClearReset
Self
Test
Status
Fan
Power
Modules
Status
Fan
Power
ModulesLED Mode Select
ActDCBA21
LED Mode Select
ActDCBA21
Max
FDx
!
Use xl modules only
A
C
Max
FDx
!
Use xl modules only
A
procurve
xl
xlmodule
J4820B
C
Figure 1-1. Example 5304xl chassis and 5348xl bundle
D
xl
D
1-1
Page 10
Introducing the ProCurve Switch 5300xl Series
ProCurve
Switch 5304xl-32G
bundle (J8166A)
with two 16 port
100/1000-T xl Modules
preinstalled
Switch 5300xl Series
Introducing the ProCurve
Figure 1-2. Example 5304-32G bundle
Switch 5308xl and Switch 5372xl and the Switch 5308xl-48G. The
Switch 5308xl is available as an open 8-slot chassis (J4819A), as the Switch
5372xl bundle (J4848B) with three 24-port 10/100-TX xl Modules pre-installed
and as the Switch 5308xl-48G bundle (J8167A) with three 16-port
100/1000-T xl Modules pre-installed.
hp procurve
switch 5308xl
J4819A
!
Use xl modules only
ProCurve Switch5308xl
(J4819A)
Figure 1-3. Example 5308xl chassis
1-2
Page 11
ProCurve
Switch 5372xl
bundle (J4848B)
with three
10/100-TX xl Modules
preinstalled
hp procurve
switch 5308xl
J4819A
hpprocurve10
/
100-TX
xl module
J4820B
Clear
Reset
Console
1 2 A B C D E F G H
Self
Fan
Power
Test
Status
ModulesLED Mode Select
Figure 1-4. Example 5372xl bundle
Introducing the ProCurve Switch 5300xl Series
Max
FDx
Act
Use xl modules only
hp procurve
10
/
100-TX
xl module
J4820B
hpprocurve10
/
100-TX
xl
xl module
J4820B
Introducing the ProCurve
Switch 5300xl Series
xl
xl
ProCurve
Switch 5308xl-48G
bundle (J8167A)
with three
100/1000-T xl Modules
preinstalled
Figure 1-5. Example 5308xl-48G bundle
See “Switch Features” on page 1-10 for a list of the switch modules that you
can install in the ProCurve Switch 5300xl Series (modules available when this
manual was printed).
1-3
Page 12
Introducing the ProCurve Switch 5300xl Series
Front of the Switch
Front of the Switch
Status LEDs for the
Console
Port
Switch 5300xl Series
Introducing the ProCurve
Power
and Fault
LEDs
Reset and Clear
buttons
Fans, Power Supplies,
and Switch Modules
LED Mode Select button
and indicator LEDs
hp procurve
switch 5304xl
J4850A
procurve
xl module
J4820A
Console
ClearReset
Status
Self
Fan
Power
Test
ModulesLED Mode Select
Max
FDx
ActDCBA21
!
Use xl modules only
A
procurve
xl
xl module
J4820A
C
Self Test LED
Switch Modules and slots
with Link and Mode LE Ds for each port located on each module
Figure 1-6. Example front description
This illustration shows the 5348xl, but the labeling and descriptions apply to
all of the ProCurve Switch 5300xl Series.
xl
D
1-4
Page 13
Introducing the ProCurve Switch 5300xl Series
Front of the Switch
LEDs
As described in the next two tables, there are LEDs on the switch chassis and
on the switch modules that keep you informed of the status of the switch and
the network connections.
Table 1-1.Switch Chassis LEDs
LEDsStateMeaning
Power
(green)
Fault
(orange)
Self Test
(green)
OnThe switch is receiving power.
OffThe switch is NOT receiving power.
OffThe normal state; indicates that there are no fault conditions on the switch.
Flashing
OnOn briefly at the beginning of switch self test after the switch is powered on or reset. If on
OffThe normal operational state; the switch is not undergoing self test.
OnThe switch self test and initialization are in progress after you have power cycled or reset
Flashing
†
A fault has occurred on the switch, one of the switch modules, an individual port, a power
supply, or a fan. The Status LED for the module or other device with the fault will flash
simultaneously.
for a prolonged time, the switch has encountered a fatal hardware failure, or has failed its
self test. See chapter 4, “Troubleshooting” for more information.
the switch. The switch is not operational until this LED goes off. The Self Test LED also
comes on briefly when you “hot swap” a module into the switch and the module is
automatically self tested.
†
A component of the switch has failed its self test. The Status LED for that component, for
example a switch module, and the switch Fault LED will flash simultaneously.
Introducing the ProCurve
Switch 5300xl Series
Status/Fan
(green)
Status/Power
(green numbers
corresponding
to the power
supply
positions)
OnThe cooling fans are operating normally.
Flashing
OnA power supply is installed in the position in the back of the switch corresponding to the
OffA power supply is not installed in the position corresponding to the number.
Flashing
†
One or more of the cooling fans have failed. The switch Fault LED will be flashing
simultaneously.
number, and the supply is plugged in to an active AC power source. As shipped, the switch
has a single power supply in position 1.
†
The power supply installed in the position corresponding to the number is not plugged in
to an active AC power source, or has experienced a fault. The switch Fault LED will be
flashing simultaneously.
1-5
Page 14
Introducing the ProCurve Switch 5300xl Series
Front of the Switch
LEDsStateMeaning
Status/
Modules
(green - letters
corresponding
to the switch
module slots)
Switch 5300xl Series
Introducing the ProCurve
LED Mode
Select
(3 green LEDs)
†
The flashing behavior is an on/off cycle once every 1.6 seconds, approximately.
OnA module is installed in the switch module slot corresponding to the letter and the module
OffA module is not installed in the switch module slot corresponding to the letter.
Flashing
ActIndicates that the port Mode LEDs are displaying network activity information.
FDxIndicates that the port Mode LEDs are lit for ports that are in Full Duplex Mode.
MaxIndicates that the port Mode LEDs are lit for ports that are operating at their maximum
!
is undergoing or has passed self test. This also occurs when you install a module when
the switch is already powered on (“hot swap”).
†
The module status LED flashes very briefly when a module is being hot swapped. If the LED
flashes for a prolonged time, the module in the slot corresponding to the letter has failed
self test or encountered some other fault condition. See chapter 4, “Troubleshooting” for
a more information.
possible link speed -- for any Gigabit-capable connection, that would be 1000 Mbps; for
the 10/100-TX ports and 100-FX ports, that would be 100 Mbps.
Indicates tha t specifi c error packets are being detec ted on the port. In this mode, the Mode
LED for the port will flash briefly for each error packet that is detected, for example CRC
errors or late collisions. See chapter 4, “Troubleshooting” for more information.
Table 1-2.Switch Module LEDs
The following LEDs are located on the modules themselves, one pair for each
port.
LEDStateMeaning
Link OnIndicates the port is enabled and receiving a link beat signal (for the twisted-pair
OffOne of these conditions exists:
Flashing†The port has failed self test. The switch Fault, Self Test LEDs, and appropriate
ModeDepending on the mode selected, displays the following: network activity information, whether
the port is configured for Full Duplex operation, maximum speed op eration, or whether networ k
errors are occurring on the port. See “LED Mode Select Button and Indicator LEDs” below for
more information.
†
The flashing behavior is an on/off cycle once every 1.6 seconds, approximately.
ports), or a strong enough light le vel (for the fiber-optic por ts) from the connected
device.
• no active network cable is connected to the port
• the port is not receiving link beat or sufficient light
• the port has been disabled through the switch console, the web browser
interface, ProCurve Manager, or other network management tool.
module status LEDs will flash simultaneously.
1-6
Page 15
Introducing the ProCurve Switch 5300xl Series
Front of the Switch
LED Mode Select Button and Indicator LEDs
To optimize the amount of information that can be displayed for each of the
switch ports, the Switch 5300xl Series use a Mode LED for each port. The
operation of this LED is controlled by the LED Mode Select button on the
switch chassis, and the current selection is indicated by the mode indicator
LEDs near the button. Press the button to change from one mode to the next.
LED Mode Select button
and indicator LEDs
Status
n
Power
ModulesLED Mode Select
Max
FDx
ActDCBA21
!
Mode LEDs
(one for each port)
Use xl modules only
A
procurve
xl
xl module
J4820A
Introducing the ProCurve
Switch 5300xl Series
C
Figure 1-7. Example Mode Select button and Mode LEDs
■If the Activity indicator LED is lit, each port Mode LED displays
activity information for the port—it flickers as network traffic is received
and transmitted through the port.
■If the Full Duplex indicator LED is lit, the port Mode LEDs light for
those ports that are operating in full duplex.
■If the maximum speed indicator LED is lit, the port Mode LEDs light
for those ports that are operating at their maximum possible link speed,
for example 1000 Mbps on a 100/1000-T port.
■If the attention indicator LED is lit, each Mode LED lights briefly for
each network event that might require operator attention, for example,
late collisions or CRC errors. See chapter 4, “Troubleshooting” for more
information.
Act
FDx
Max
!
1-7
Page 16
Introducing the ProCurve Switch 5300xl Series
Front of the Switch
Console Port
This port is used to connect a console to the switch by using the serial cable
supplied with the switch. This connection is described under “Connecting a
Console to the Switch” in chapter 2, “Installing the Switch 5300xl Series”. The
console is a full-featured interface that can be used to configure, monitor, and
troubleshoot the switch. It can be run on a PC, laptop, or handheld device
emulating a VT-100 terminal, or on a standard VT-100 terminal.
Switch 5300xl Series
Introducing the ProCurve
Reset Button
This button is used to reset the switch while it is powered on. This action clears
any temporary error conditions that may have occurred, executes the switch
self test, and resets all network activity counters to zero. The counters are
displayed in the switch console interface, the switch web browser interface,
and through SNMP network management applications, such as ProCurve
Manager.
Press the Reset button also after changing the module type that is installed in
any of the switch module slots while the switch is powered on. In this case,
the switch must be reset to initialize the new module type. See “Hot Swapping
Switch Modules” on page 2-21.
1-8
Clear Button
This button is used for the following purposes:
■Deleting Passwords - When pressed by itself for at least one second, the
Clear button deletes any switch console access passwords that you may
have configured. Use this feature if you have misplaced the password and
need console access.
This button is provided for your convenience, but its presence means that
if you are concerned with the security of the switch configuration and
operation, you should make sure the switch is installed in a secure
location, such as a locked wiring closet.
■Restoring Factory Default Configuration - When pressed with the
Reset button in a specific pattern, the Clear button clears any configuration changes you may have made through the switch console, the web
browser interface, or SNMP management, and restores the factory default
configuration to the switch. For the specific method to restore the factory
default configuration, see “Restoring the Factory Default Configuration”
in chapter 4, “Troubleshooting” of this manual.
Page 17
Back of the Switch
.
Introducing the ProCurve Switch 5300xl Series
Back of the Switch
Introducing the ProCurve
Switch 5300xl Series
AC power connector
pull strap
Figure 1-8. Example back of 5300xl Series
slot for installing optional
redundant power supply
Power Connector
The Switch 5300xl Series do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.
Slot for Redundant Power Supply
A second, load-sharing redundant power supply (ProCurve Switch gl/xl RPS,
J4839A) can be installed in the back of the Switch 5300xl Series. To provide
true redundancy, this second power supply should be connected to a different
AC power source from the other supply. Then, if one AC power source fails,
the switch will continue to run.
CautionThe switch redundant power supply is hot swappable, but, as indicated by the
caution statement on the power supply, it must be disconnected from AC
power before being installed or removed.
Caution:
.
Refer to the installation guide for proper power cord selection.
.
Disconnect AC power from this power supply BEFORE installing or removing
the supply. Otherwise, damage to the equipment may result.
Because the switch can run on a single supply, removing a redundant supply
will not interrupt switch operation.
1-9
Page 18
Introducing the ProCurve Switch 5300xl Series
Switch Features
Switch Features
The features of the Switch 5300xl Series include:
■4 or 8 slots for installing any of the available Switch xl Modules.
Supported Modules: As of this printing, the supported xl modules
Switch 5300xl Series
Introducing the ProCurve
includes:
•Access Control xl Module (J8162A) -- operates as an access controller
(ProCurve Access Controller 720wl) for a wireless network and it
must be connected to an access control server (either a ProCurve
Access Control Server 740wl or a ProCurve Integrated Access
Manager 760wl).
•24-port 10/100-TX xl Module (J4820B)
•4-port 100/1000-T xl Module (J4821B)
•4-port mini-GBIC xl Module (J4878B) -- into which you can install the
supported mini-GBICs, the Gigabit-SX LC mini-GBIC (J4858A), the
Gigabit-LX LC mini-GBIC (J4859A), the Gigabit-LH LC mini-GBIC
(J4860A), and the 1000Base-T mini-GBIC (J8177B)
•12 port 100-FX MTRJ xl Module (J4852A) - provides 12 100-FX ports
with MT-RJ connectors for 100 Mbps networking over multimode
fiber-optic cable.
•16 port 10/100/1000Base-T xl Module (J4907A) -- includes 14 10/100/
1000-T ports and two dual personality ports: 10/100/1000-T or miniGBIC
•24-port 10/100-TX xl PoE Module (J8161A) -- which, when connected
to a ProCurve 600 Redundant and External Power Supply(J8168A),
can provide Power over Ethernet (PoE) power to 802.3af compliant
devices. For more information on PoE power refer to the ProCurve PoE Planning and Implementation Guide. For more information on
the J8161A module refer to the ProCurve Switch xl Modules Instal-lation Guide.
CautionFor safe and reliable operation, disconnect EPS cable before installing or
removing J8161A modules. For more information refer to the ProCurve
Switch xl Modules Installation Guide.
•1-port 10-GbE xl Module (J8988A) -- into which you can install the
supported transceivers, the ProCurve 10-GbE X2-SC SR Optic
(J8436A), the ProCurve 10-GbE X2-SC LR Optic (J8437A), the
ProCurve 10-GbE X2-SC ER Optic (J8438A), the ProCurve 10-GbE X2
CX4 Xcvr (J8440B), and the ProCurve 10-GbE CX4 Optical Media
Converter (J8439A)
1-10
Page 19
Introducing the ProCurve Switch 5300xl Series
Switch Features
■the modules can be installed in any order and in any combination and can
be “hot swapped”.
■the supported mini-GBICs can be hot swapped into the mini-GBIC xl
Module.
■the supported transceivers can be hot swapped into the 10-GbE vl Module.
■plug-and-play networking—all ports are enabled—just connect the
network cables to active network devices and your switched network is
operational.
■automatic learning of the network addresses in the switch’s 16,000-
address forwarding table, with configurable address aging value.
■full-duplex operation available on all ports.
■easy management of the switch through several available interfaces:
•web browser interface—an easy to use built-in graphical interface
that can be accessed from common web browsers.
•console interface—a full featured, easy to use, VT-100 terminal interface for out-of-band switch management, or for telnet access to the
switch. The console includes complete switch management through
a command line interface (CLI) and a slightly reduced feature set
accessible through an intuitive menu interface.
•ProCurve Manager—an SNMP-based graphical interface that is used
to manage your entire network, included with your new switch.
•Supported by ProCurve Network Manager—an HP OpenView application that accurately displays your switch on network maps and
provides a graphical interface for configuring and monitoring your
switch.
■support for the Spanning Tree Protocol to eliminate network loops.
■support for up to 256 IEEE 802.1Q-compliant VLANs so you can divide the
attached end nodes into logical groupings that fit your business needs.
■Layer 3 routing functionality:
•IP static routes
•RIP V1 and V2
•IRDP - ICMP Router Discovery Protocol
•OSPF- Open Shortest Path First
•DHCP relay
■support for many other advanced features to enhance network perfor-
mance, security, and control— for a description, see the Management and
Configuration Guide that is on the ProCurve Web site, www.procurve.com.
Introducing the ProCurve
Switch 5300xl Series
1-11
Page 20
Page 21
Installing the Switch 5300xl Series
The Switch 5300xl Series is easily installed. They come with an accessory kit
that includes the brackets for mounting the switch in a standard 19-inch telco
rack, in an equipment cabinet, or on a wall. The switches have rubber feet
already attached so they can be securely located on a horizontal surface. This
chapter shows you how to install your Switch 5300xl Series.
Included Parts
The Switch 5300xl Series have the following components shipped with them:
■ProCurve Switch 5300xl Series Installation and Getting Started Guide,
this manual
■ProCurve Manager - CD ROM and booklet
■Customer Support/Warranty booklet
■Accessory kit (5065-6521 for the 8-slot Switch 5308xl, Switch 5372xl, and
Switch 5308xl-G48; 5064-9943 for the 4-slot Switch 5304xl, Switch 5348xl,
and Switch 5304xl-G32):
•two mounting brackets
•six 10 mm M4 screws to attach the mounting brackets to the switch
•four 5/8-inch number 12-24 screws to attach the switch to a rack
■Console cable
2
Installing the Switch 5300xl
Series
2-1
Page 22
Installing the Switch 5300xl Series
Included Parts
■Power cord, one of the following:
Series
Installing the Switch 5300xl
Japan Power
Cord Warning
Australia/New Zealand
China
Continental Europe
Denmark
Japan
Switzerland
United Kingdom/
Hong Kong/Singapore
United States/Canada/
Mexico
8120-6803
8120-8377
8120-6802
8120-6806
8121-0606
8120-6807
8120-8709
8121-0605
2-2
Page 23
Installing the Switch 5300xl Series
Installation Procedures
Installation Procedures
Summary
Follow these easy steps to install your switch. The rest of this chapter provides
details on these steps.
1.Prepare the installation site (page 2-6). Make sure that the physical
environment into which you will be installing the switch is properly
prepared including having the correct network cabling ready to connect
to the switch, and having a good location for the switch. Please see page
2-5 for some installation precautions.
2.Install switch modules (page 2-8). The Switch 5300xl Series have four
or eight universal slots for installing any of the ProCurve Switch xl
modules. The Switch 5372xl has three 24-port 10/100-TX xl Modules
preinstalled, and the Switch 5348xl has two 24-port 10/100-TX xl Modules
preinstalled. Depending on where you will install your Series 5300xl
Switch, it may be easier to install the modules first. The modules are “hot
swappable” though, so they can also be installed and removed after the
switch is powered on.
Installing the Switch 5300xl
Series
Note Make sure you use only ProCurve Switch xl Modules in your Switch 5300xl
Series.
3.(Optional) Install second power supply (page 2-10). The Switch
5300xl Series have a slot in the back for installing a second, load-sharing
power supply. If you have purchased this supply, it may be easier to install
it before mounting the switch.
4.Verify the switch passes self test (page 2-12). This is a simple process
of plugging the switch into a power source and observing that the LEDs
on the switch’s front panel and on the modules show correct operation.
5.Mount the switch (page 2-14). The Switch 5300xl Series can be mounted
in a 19-inch telco rack, in an equipment cabinet, on a wall, or on a
horizontal surface. Note that there are some limitations to the wall
mounting orientations that are supported. Please see the installation
details for more information.
6.Connect power to the switch (page 2-18). Once the switch is mounted,
plug it in to the nearby main power source.
2-3
Page 24
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Installation Procedures
7.Connect the network devices (page 2-18). Using the appropriate
network cables, connect other switches, hubs, routers, computers,
servers, printers, and other network devices to the switch ports. For more
information, see “Connect the Network Devices” on page 2-18.
Note The 10/100Base-TX ports on the 10/100-TX and PoE xl Modules have the
HP Auto-MDIX feature, and the 100/1000Base-T ports on the 100/1000-T
xl Module comply with IEEE 802.3ab standard which includes the Auto MDI/MDI-X feature. These two features operate the same and allow you
to use straight-through twisted-pair cable for all of your twisted-pair
network connections.
8.(Optional) Connect a console to the switch (page 2-19). You ma y
wish to modify the switch’s configuration, for example, to configure an IP
address so it can be managed using a web browser or from an SNMP
network management station. Configuration changes can be made easily
through the switch’s console interface.
At this point, the switch is fully installed. See the rest of this chapter if you
need more detailed information on any of these installation steps.
WARNING
2-4
Installation Precautions
Follow these precautions when installing your Series 5300xl Switch:
■Devices installed in a rack or cabinet should be mounted as low
as possible, with the heaviest device at the bottom and progressively lighter devices installed above.
The rack or cabinet should be adequately secured to prevent it
from becoming unstable and/or falling over.
■Ensure a cover plate is installed on any empty switch power
supply slot. A cover plate is required for safe operation, and
to ensure proper switch cooling.
■To avoid energy and mechanical hazards, never allow any part
of your body, jewelry, tool, or other foreign object to enter any
module or power supply slots.
Page 25
Installing the Switch 5300xl Series
Installation Precautions (continued)
Installation Procedures
Cautions
■Ensure the power source circuits are properly grounded, then use the
power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied
with the switch and power supply, be sure the cord is adequately sized
for the switch’s current requirements. In addition, be sure to use a power
cord displaying the mark of the safety agency that defines the regulations
for power cords in your country. The mark is your assurance that the
power cord can be used safely with the switch and power supply.
■When installing the switch, note that the AC outlet should be near the
switch and should be easily accessible in case the switch must be
powered off.
■Ensure the switch does not overload the power circuits, wiring, and over-
current protection. To determine the possibility of overloading the supply
circuits, add together the ampere ratings of all devices installed on the
same circuit as the switch and compare the total with the rating limit for
the circuit. The maximum ampere ratings are usually printed on the
devices near the AC power connectors.
■Do not install the switch in an environment where the operating ambient
temperature might exceed 40°C (104°F).
■Allow three to four inches of space around the sides and back of the
switch to make sure the air flow for the switch is not restricted.
■Ensure that for any switch slot into which no module is installed, the
cover plate is installed to cover the slot. A cover plate is required for safe
operation, and to ensure proper switch cooling. For safety, you should
never have more than one module slot uncovered at a time while the
switch is powered on.
Installing the Switch 5300xl
Series
■For safe and reliable operation, disconnect EPS cable before installing
or removing J8161A modules. For more information refer to th e ProCurve
Switch xl Modules Installation Guide.
2-5
Page 26
Installing the Switch 5300xl Series
Installation Procedures
1. Prepare the Installation Site
Cabling Infrastructure
Ensure the cabling infrastructure meets the necessary network specifications.
See the following table for cable types and lengths, and see appendix B,
“Switch Ports and Network Cables” on page B-1 for more information:
Table 2-1.Summary of Cable Types to Use with the Switch
Port TypeCable TypeLength Limits
Twisted-Pair Cables
Series
Installing the Switch 5300xl
10/100/1000Base-T For either 10, 100 Mbps or 1000 Mbps
Gigabit-SX
(on Gigabit-SX-LC
mini-GBIC)
Gigabit-LX
(on Gigabit-LX-LC
mini-GBIC)
operation:
Category 5 or better, 100-ohm UTP or shielded
twisted-pair (STP) balanced cable. For 1000
Mbps (gigabit) operation, Category 5e cabling
or better is recommended.
Fiber Optic Cables
Multimode fiber-optic cables fitted with LC
connectors
Single-mode fiber-optic cables fitted with LC
connectors.
The multimode cables specified for the GigabitSX mini-GBIC may also be used, but a modeconditioning pa tch cord may be needed — See
the Installation Guide that came with your
module for more information.
100 meters
Note: The ProCurve 10/100/1000-T xl
Modules and 100/1000-T Transceiver are
compatible with the IEEE 802.3ab standard
including the “Auto MDI/MDI-X” feature,
which allows use either straight-through or
crossover twisted-pair cables for
connecting to any network devices
including end n odes, such as computers, or
to other switches, hubs, and routers.
The Auto MDI/MDI-X feature only works
when the port is in auto-negotiation mode.
220 meters to 550 meters depending on the
cable used. See “Fiber-Optic Cables” on
page B-3 for more information.
• single-mode cable = 10 kilometers
• multimode cable = 550 meters
Gigabit-LH
(on Gigabit-LH-LC
mini-GBIC)
Note:
Gigabit-LH - The transmission distances are dependent on the particular fiber loss and coupling loss involved, among
other factors, and can be estimated from the optical loss budget. For distances less than 20km, a 10dB attenuator must
be used. For distances between 20km and 40km, a 5dB attenuator must be used. Attenuators can be purchased from
most cable vendors.
The same singl e-mode fiber-optic cables a s for
Gigabit-LX.
• 70 kilometers
2-6
Page 27
Installing the Switch 5300xl Series
Port TypeCable TypeLength Limits
Installation Procedures
10-GbE SRMultimode fiber-optic cable designed for
Gigabit Ethernet: 62.5/125 μm (core/cladding)
diameter or 50/125 μm, low metal content,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
■62.5 μm cable:
•160 Mhz/km = 2-26 meters
•200 Mhz/km = 2-33 meters
■50 μm cable:
•400 Mhz/km = 2-66 meters
•500 Mhz/km = 2-82 meters
•2000 Mhz/km = 2-300 meters
10-GbE LR9/125 μm (core/cladding) diameter, low metal
single-mode cable: 2-10 kilometers
content, single mode fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
10-GbE ER9/125 μm (core/cladding) diameter, low metal
content, single mode fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC
single-mode cable: 2-30 kilometers (40
kilometers, on an engineered fiber optic link
that meets standards in the specification).
793-2 Type B1 standards.
Note: Conditioning patch cord cables are not supported on 10-GbE.
Before installing the switch, plan its location and orientation relative to other
devices and equipment:
■In the front of the switch, allow at least 7.6 cm (3 inches) of space for the
twisted-pair and fiber-optic cabling.
■In the back of the switch, allow at least 10.2 cm (4 inches) of space for the
power cord and cooling.
■On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling.
0.5-15 metersCX4
2-7
Page 28
Installing the Switch 5300xl Series
Installation Procedures
2. Install Switch xl Modules
Install switch modules into the slots as shown in the illustration below. For
installation details, see the instructions in the manual that comes with the
module.
CautionMake sure you install only ProCurve Switch xl Modules. Switch gl and
vl Modules will fit into your Switch xl slots, but they will not operate.
Avoid any electrostatic discharge problems by handling the modules only by
their bulkheads.
The slot cover can be removed, and the module can be installed with either a
flat-bladed or Torx T-10 screwdriver. Retain the slot cover for future use.
Series
Installing the Switch 5300xl
Module
Installation
Notes
■Any of the supported Switch xl Modules can be installed in any of the slots.
■The modules can be “hot swapped”, installed after the switch is already
powered on, and normally will be immediately operational. But, if you are
replacing a module with a different type than what was previously
installed in the slot, the switch must be rebooted after the module is
installed. See “Hot Swapping the Switch Module” on page 2-21.
■The modules employ “low-force” connectors. Using high force to insert
the modules is not needed and should not be used.
■Ensure you fully insert the modules. That is, press the module into the slot
until the bulkhead on the module is contacting or is very close to
contacting the front face of the switch chassis.
■Once the module is fully inserted, ensure that you screw in the two
retaining screws to secure the module in place. The screws should be
tightened until they are secure, but not overtightened.
■If you do not use one or more of the slots, ensure the slot cover plate is
still attached over the slot for safe operation and proper switch cooling.
For safety, you should not have more than one module slot uncovered at
a time.
2-8
Page 29
1.insert module into the
guides and slide it in until
it is fully inserted.
Installing the Switch 5300xl Series
Installation Procedures
“Low-force” connector.
High insertion force is not
needed and should not be
used.
Installing the Switch 5300xl
Series
Figure 2-1. Installing a module
the module is fully inserted when the
module bulkhead is contacting, or
very close to contacting
the face of the switch.
Figure 2-2. Tighting module retaining screws
2. then tighten the retaining screws on
the module until they are sec ure, but do
not overtighten them.
2-9
Page 30
Installing the Switch 5300xl Series
Installation Procedures
3. (Optional) Install Second Power Supply
A second, load-sharing redundant power supply (ProCurve Switch gl/xl/vl
RPS, J4839A) can be installed in the back of the switch. To provide true
redundancy, this second power supply should be connected to a different AC
power source from the other supply. Then, if one AC power source fails, the
switch will continue to run. Each supply provides enough power to operate a
fully loaded switch, so even if one fails, the switch will continue to operate
normally.
Install the second power supply into power slot number 2 as shown in the
illustration on the next page.
The slot cover can be removed with either a flat-bladed or Torx T-10 screwdriver. Retain the slot cover for future use.
CautionThe switch power supplies are hot swappable; they can be installed while the
Series
switch is receiving power from the supply in the other slot. But, as indicated
by the caution statement on the power supply, the supply must not be connected to AC power before being installed.
Installing the Switch 5300xl
Caution:
.
Refer to the installation guide for proper power cord selection.
.
Disconnect AC power from this power supply BEFORE installing or removing
the supply. Otherwise, damage to the equipment may result.
For safety and proper switch cooling, if either of the power supply slots are
not being used, make sure to attach the cover plate over the slot. Please see
the “Installation Precautions” on page 2-5 for more information.
For installation details, see the instructions in the manual that comes with the
power supply.
2-10
Page 31
Insert the power supply into the
opening, then slide it all the way
in until it connects to the switch.
The power supply face plate will
be flush with the back face of the
switch.
Figure 2-3. Installing a power supply
Installing the Switch 5300xl Series
Installation Procedures
Installing the Switch 5300xl
Series
Once the power supply is installed, ensure you tighten the four retaining
screws that hold it in place. The screws can be tightened with either a flatbladed or Torx T-10 screwdriver. Be careful not to overtighten the screws.
tighten the
four screws
Figure 2-4. Tighting the power supply retaining screws
2-11
Page 32
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Installation Procedures
4. Verify the Switch Passes Self Test
After you have installed any modules and the optional second power supply,
but before mounting the switch in its network location, you should first verify
it is working properly by plugging it into a power source and verifying it passes
its self test.
If you have installed a second power supply, repeat these procedures with the
second power supply to verify it works correctly also.
1.Connect the power cord supplied with the switch to the power connector
on the back of the switch, and then into a properly grounded electrical
outlet.
connect power cor d to
power connector
Figure 2-5. Connecting the power cord
NoteThe Switch 5300xl Series does not have a power switch. They are powered on
when the power cord is connected to the switch and to a power source.
If your installation requires a different power cord than the one supplied with
the switch, please see the “Installation Precautions” on page 2-5.
2.Check the LEDs on the switch and on each of the switch modules. The
LED behavior is described on the next page.
If the LED display is different than what is described, especially if the
Fault LED stays on for more than approximately 120 seconds or it starts
flashing, the self test has not completed correctly. Refer to chapter 4,
“Troubleshooting” for diagnostic help.
2-12
Page 33
Installing the Switch 5300xl Series
switch chassis LEDs
Installation Procedures
switch module LEDs:
Link and Mode LEDs
for each port
hp procurve
switch 5304xl
J4850A
procurve
xl module
Console
ClearReset
Self
Test
Status
Fan
Power
ModulesLED Mode Select
Max
FDx
ActDCBA21
!
A
xl
Figure 2-6. Switch LEDs
When the switch is powered on, it performs its diagnostic self test. The entire
download, initialization, and self test process can take up to 2 minutes for a
fully loaded chassis, depending on the number and type of modules installed
in the switch.
LED Behavior:
During the self test:
■Initially, Power and Fault, and all the switch chassis LEDs are on. Then,
after approximately 30 seconds, all the module LEDs go on as the modules
receive power and code is downloaded to them, the Fault LED goes off,
and the chassis LEDs go off except Power, Self Test, Fan Status, and Power Status.
■When the download of code to the modules is completed, the module
LEDs go off. You may see each port LED go on briefly, in sequence, as the
port is tested.
■For the duration of the self test, the Self Test LED stays on.
xl
Installing the Switch 5300xl
Series
When the self test completes successfully:
■The Power LED stays on, and the Status LEDs on the switch chassis stay
on for the devices installed: one for each switch module installed, one for
each power supply installed, and one for all the fans.
■The Fault and Self Test LEDs are off.
■The port LEDs on the switch modules go into their normal operational
mode:
•If the ports are connected to active network devices, the Link LEDs
stay on and the Mode LEDs behave according to the mode selected.
In the default mode (Activity), the Mode LEDs should flicker showing
network activity on the port.
•If the ports are not connected to active network devices, the LEDs
will stay off.
2-13
Page 34
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Installation Procedures
5. Mount the Switch
After the modules and optional power supply are installed and you have
verified the switch passes self test, you are ready to mount the switch in a
stable location. The Switch 5300xl Series can be mounted in these ways:
■in a rack or cabinet
■on a horizontal surface
■on a wall
Rack or Cabinet Mounting
The Switch 5300xl Series is designed to be mounted in any EIA-standard 19inch telco rack or in an equipment cabinet such as a server cabinet. If you are
installing the switch in an equipment cabinet, please see the “Equipment
Cabinet Note” on page 2-16.
CautionFor safe operation, please read the “Installation Precautions” on page 2-5
before mounting the switch.
1.Use a #1 Phillips (cross-head) screwdriver and attach the mounting
brackets to the switch with the included 10-mm M4 screws.
For the Switch 5304xl and Switch 5348xl, each bracket is attached with
two screws, and for the Switch 5308xl and Switch 5372xl each bracket is
attached with three screws as shown in the illustrations on the next page.
2-14
10 mm
M4 screws
Figure 2-7. Attaching brackets to the switch 5308xl
Page 35
Installing the Switch 5300xl Series
Installation Procedures
2.Partially install a screw (5/8-inch number 12-24) into the top hole of a pair
of holes that are 0.5 inches apart in each rack/cabinet upright as shown
in the illustration below. Ensure that the screws are at the same level in
each upright.
.
partially install a screw
into the top hole of a
close (0.5-inch) pair on
both sides of the rack
Installing the Switch 5300xl
Series
Figure 2-8. Partially installed screw for bracket notch
3.Place the switch in the rack and lower it so the notches in the bottom of
the bracket slide onto the screws, then tighten these screws.
lower the switch with
mounting brackets onto the
partially installed screws,
then tighten these screws
Figure 2-9. Setting the bracket notch
2-15
Page 36
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Installation Procedures
4.Install the other number 12-24 screw into the upper hole in each bracket.
Tighten these screws.
install and tighten the
other 12-24 screws
Figure 2-10. Installing the final rack mounting screw
Equipment
Cabinet
Note
If you are installing the switch in an equipment cabinet, in place of the
12-24 screws supplied with the switch, use the clips and screws that came with
the cabinet. Plan which four holes you will be using in the cabinet and install
all four clips and partially install the two bottom screws, as described in step
2 on the previous page, before proceeding to step 3.
Horizontal Surface Mounting
Place the switch on a table or other horizontal surface. Use a sturdy surface
in an uncluttered area. You may want to secure the networking cables and
switch power cord to the table legs or other part of the surface structure to
help prevent people from tripping over the cords.
NoteEnsure the air flow is not restricted around the sides and back of the switch.
2-16
Page 37
Installing the Switch 5300xl Series
Installation Procedures
Wall Mounting
The mounting brackets supplied with the switch allow you to mount it on a
wall. The illustrations below show mounting a Switch 5308xl/5372xl. The
Switch 5304xl/5348xl would be mounted in a similar way.
CautionFor safe operation, do not install the switch with the vents or fans facing
downward. The only recommended and supported wall mounting orientation
is with the unit upright and the modules facing out, as shown in the illustrations below.
Additionally, the switch should be mounted only to a wall or wood surface
that is at least 1/2-inch plywood or its equivalent.
1.Use a #1 Phillips
(cross-head)
screwdriver and
attach the
mounting brackets
to the switch with
the included
10-mm M4 screws.
10 mm
M4 screws
Installing the Switch 5300xl
Series
2.Attach the
switch to the
wall or wood
surface with four
5/8-inch number
12 wood screws
or larger (not
included).
Figure 2-11. Attaching brackets to the rear of the
switch
5/8-inch
number 12
wood screws
Figure 2-12. Mounting to a wall
2-17
Page 38
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Installation Procedures
6. Connect the Switch to a Power Source
1.Plug the included power cord into the switch’s power connector and into
a nearby properly grounded AC power source.
If you have installed a redundant power supply module into the switch, it
should be connected to a separate AC power source. Then, if there is a
power outage from one of the AC sources, the switch will continue to
operate by power coming from the other source.
See the ProCurve Switch gl/xl/vl RPS Installation Guide for additional
information.
2.Re-check the LEDs during self test. See “LED Behavior” on page 2-13.
7. Connect the Network Devices
The type of network connections you will need to use depends on the types
of switch modules you have installed in your Series 5300xl Switch. See the
documentation accompanying the modules for cabling configurations and
procedures for those modules.
In general for all the modules, when a network cable from an active network
device is connected to the switch, the Link LED for the switch port should go
on. If the Link LED does not go on, use the table below to help solve the
problem, and see the module documentation for troubleshooting procedures.
ConditionDiagnostic Tip
Port LED is
still off when
a cable is
connected
Try the following procedures:
• For the indicated port, verify both ends of the cabling, at the switch and the connected device, are
securely connected.
• Verify the connected device and switch are both powered on and operating correctly.
• Verify you have used the correct cable type for the connection:
– for all twisted-pair connections, the RJ-45 connectors on the Switch 5300xl Series allow you
to use either “straight-through” cable or “crossover” cable when the port is in the “Auto”
configuration.
– for fiber-optic connections, verify the transmit port on the switch is connected to
the receive port on the connected device, and the switch receive port is connected to
the transmit port on the connected device.
See appendix B, “Switch Ports and Network Cables” for information on cables.
• Verify the port has not been disabled through a switch configuration change.
• Verify the connection parameters in the configurations of the switch port and the connected
device match. Mismatched configurations are a frequent cause of connection problems.
You can use the console interface, or, if you have configured an IP address on the switch, use the
web browser interface, or ProCurve Manager network management software to determine the
state and configuration of the port and re-enable the port if necessary.
• If the other procedures don’t resolve the problem, try using a different port or a different cable.
2-18
Page 39
Installing the Switch 5300xl Series
Installation Procedures
8. (Optional) Connect a Console to the Switch
The Switch 5300xl Series have a full-featured, easy to use console interface
for performing the following tasks:
■Monitor switch and port status and observe network activity counters
■Modify the switch’s configuration
■Read the event log and access diagnostic tools to help in troubleshooting
■Download new software to the switch
■Add passwords and other security features to control access to the switch
from the console, web browser interface, and network management
stations
The console can be accessed through these methods:
■Out-of-band: Connect a PC or VT-100 terminal, to be used as a console,
directly to the switch using the serial cable that comes with the Switch
5300xl Series. If the PC or terminal has a 25-pin serial connector, you can
use a readily available 9-pin to 25-pin serial cable, or attach a 9-to-25 pin
straight-through adapter to the PC end of the cable.
■In-Band: Access the console using telnet from a PC or UNIX station on
the network, and a VT-100 terminal emulator. This method requires that
you first configure the switch with an IP address and subnet mask by using
either out-of-band console access or through DHCP/Bootp.
Installing the Switch 5300xl
Series
The Switch 5300xl Series can simultaneously support one out-of-band console
session through the Console Port and one in-band telnet session.
Terminal Configuration
To connect a console to the switch, configure the PC terminal emulator as a
VT-100 or DEC VT-100 (ANSI) terminal, or use a VT-100 terminal and configure
it to operate with these settings:
■any baud rate from 2400 to 115200 (the switch automatically senses the
speed)
■8 data bits, 1 stop bit, no parity, and flow control set to None
■for Windows Terminal program, also disable (uncheck) the “Use Func-
tion, Arrow, and Ctrl
■for the Hilgrave HyperTerminal program, select the “Terminal keys”
option for the “Function, arrow, and ctrl keys act as” parameter
Keys for Windows” option
2-19
Page 40
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Installation Procedures
If you want to operate the console using a different configuration, ensure you
change the settings on both the terminal and on the switch. Change the switch
settings first, then change the terminal settings, and reestablish the console
session.
Direct Console Access
To connect a console to the
switch, follow these steps:
1.Connect the PC or
terminal to the switch’s
Console Port using the
console cable included
with the switch. (If your
PC or terminal has a 25pin serial connector, first
attach a 9-pin to 25-pin
straight-through adapter
to the PC end of the
console cable.)
2.Turn on the terminal or
PC’s power and, if using a
PC, start the PC terminal
program.
3.Press the Enter key two
or three times and you
will see the copyright
page and the message
“Press any key to
continue”. Press a key, and you will then see the switch console CLI
prompt.
console port
console cable
supplied with the
switch
PC running a
terminal emulator
program, or a VT100 terminal
Figure 2-13. Connecting a console
2-20
Telnet Console Access
To access the switch through a telnet session, follow these steps:
1.Ensure the switch is configured with an IP address and that the switch is
reachable from the telnet workstation (for example by using a Ping
command to the switch’s IP address)
2.Start the telnet program and connect to the switch’s IP address.
3.You will see the copyright page and the message “Press any key to
continue”. Press a key, and you will then see the switch console CLI
prompt.
Page 41
Installing the Switch 5300xl Series
Hot Swapping Switch Modules
If you want to continue with console management of the switch at this time
through either a direct connection or a telnet session, see chapter 3, “Getting
Started With Switch Configuration” for some basic configuration steps. For
more detailed information, refer to the Management and Configuration Guide which is on the ProCurve Web site, www.procurve.com.
Hot Swapping Switch Modules
The switch modules can be “hot swapped”, that is installed or replaced while
the switch is powered on (See Module Installation Notes on page 2-8). The
procedures differ slightly, though between adding new modules to an empty
slot or replacing modules with the same type, and exchanging the module with
a different type.
Adding or Replacing Modules
If a module has to be replaced with one of the same type, or you are expanding
the switch capability by adding a module in a slot where one was not previously installed (since the last switch reboot), the replaced or new module is
immediately operational; there is no interruption to the switch operation.
Changing the Module Type
If you exchange a module with a different type of module though, for example
a 100/1000-T xl Module is installed in place of a 10/100-TX xl Module that was
in the slot, the switch must be rebooted after the new module is installed so
the switch processor can properly initialize and configure the new module
type.
You can reboot the switch by any of the following methods:
■Pressing the Reset button on the front of the switch.
■Unplugging and plugging in the power cord (power cycle). If two power
supplies are installed, both power cords would have to be unplugged.
■Issuing the boot command from the switch console CLI, or selecting the
Reboot Switch option from the switch console menu, the web browser
interface, or ProCurve Manager.
Installing the Switch 5300xl
Series
Until the switch is rebooted, the module will not operate and the Module
Status LED for the affected slot will continue to flash.
2-21
Page 42
Series
Installing the Switch 5300xl
Installing the Switch 5300xl Series
Example Network Topologies
Example Network Topologies
This section shows you a few example network topologies in which the Switch
5300xl Series can be implemented. For more topology information, see the
ProCurve Networking Web site, www.procurve.com.
Basic Connectivity
server connected
by a Gigabit link
switch 5300xl
twisted-pair
straight-through
or crossover
2-22
PCs and
peripherals
Figure 2-14. Basic topology
The Switch 5300xl Series can provide basic network connectivity to a high
number of users. End nodes, printers and other peripherals, and servers can
be easily connected, as shown in the above illustration.
Notice the end node devices are connected to the switch by either straightthrough or crossover twisted-pair cables. Either cable type can be used
because of the “HP Auto-MDIX” feature on the 10/100-TX xl Modules and the
standard “Auto MDI/MDI-X” feature on the 100/1000-T xl Transceiver to which
the server is connected. The six twisted-pair ports on the
100/1000-T xl Module also support the “Auto MDI/MDI-X” feature.
Page 43
Use as an Edge Switch
Installing the Switch 5300xl Series
Example Network Topologies
trunked
redundant Gigabit
fiber-optic cables
Figure 2-15. Using the 5300 Series on the Edge
When your network expands and the users need to access resources beyond
the edge of the local network, the Switch 5300xl Series are excellent platforms
for that expansion. With the flexibility of 4 or 8 slots, the high port count 10/
100-TX xl Module for local connections, and the availability of Gigabit speeds
through either the Gigabit Transceiver xl Module or the 100/1000-T xl Module,
the Switch 5300xl Series can provide that access beyond the edge for a high
number of network users.
ProCurve
Routing Switch 9308
Fiber-Optic
Fiber-Optic
Gigabit-LX
Gigabit-LX
HP J4132A
HP J4132A
Rx
Rx
Tx
Tx
switch 5300xl
Fiber-Optic
Fiber-Optic
Gigabit-LX
Gigabit-LX
HP J4132A
HP J4132A
Rx
Rx
Tx
Tx
Installing the Switch 5300xl
Series
In the above illustration, two Switch 5308xls are connected to a ProCurve
Routing Switch 9308, which can serve as a campus backbone or core switch.
The 1000 Mbps fiber-optic connections between the two Switch 5308xls and
the Routing Switch 9308 is by way of Gigabit-LX mini-GBICs installed in
mini-GBIC xl Modules in the Switch 5308xls and Gigabit-LX ports on the
Routing Switch 9308. With the Gigabit-LX connections, the distance between
the Switch 5308xls and the Routing Switch 9308 can be up to ten kilometers.
The connections are trunked, through a configuration change on the Switch
5308xl, to provide redundancy and load sharing for higher bandwidth.
2-23
Page 44
Installing the Switch 5300xl Series
Example Network Topologies
This example configuration shows connectivity using a Switch Access
Controller xl Module (J8162A) as a 720 access controller for a wireless
network. Remember the Access Controller xl Module must be connected to
an access control server (either a ProCurve Access Control Server 740wl or a
ProCurve Integrated Access Manager 760wl).
Series
Installing the Switch 5300xl
switch 5300xl
access points
Figure 2-16. Topology integrating an Access Controller module
740/760
2-24
Page 45
Used as an Aggregation Switch
switch 5300xl
Installing the Switch 5300xl Series
Example Network Topologies
switch 5300xl
switch 5300xl
switch 8212zl
switch 5300xl
switch 5300xl
Figure 2-17. 10-GbE Aggregation Topology
The J8988A module in the Switch 5300xl Series will provide customers with a
10-GbE uplink connection (expected throughput is 2.5 to 7 Gbps, depending
on packet size). Traffic from a single MAC SA to a single MAC DA cannot
exceed 1 Gbps. Each Switch 5300xl Series can support up to four J8988A
modules. The 10-GbE module supports trunking – however, each trunk will
support at most two 10-GbE ports, and 10-GbE ports cannot be mixed with
other port speeds in the trunk.
Installing the Switch 5300xl
Series
If more than two J8988A ports are added to an IEEE 802.3ad (LACP) dynamic
trunk the remaining ports beyond the first two, as per the LACP specification,
are placed in a "standby" mode. All four ports could be placed in a dynamic
trunk. Two ports will remain on "standby" and be blocked, and two ports will
be added to the dynamic trunk. If one (or both) of the ports in the dynamic
trunk are disabled or disconnected, the highest priority "standby" port(s) will
then be added to the trunk and the disabled/disconnected port(s) will be
removed from the trunk. This works just like 10/100/1000 ports.
2-25
Page 46
Page 47
Getting Started With Switch Configuration
This chapter is a guide for using the console Switch Setup screen to quickly
assign an IP (Internet Protocol) address and subnet mask to the switch, set a
Manager password, and, optionally, configure other basic features.
For more information on using the switch console and the other switch
management interfaces: the web browser interface and the SNMP management tool, ProCurve Manager, please see the Management and Configuration Guide which is on the ProCurve Web site, www.procurve.com.
Recommended Minimal Configuration
In the factory default configuration, the switch has no IP (Internet Protocol)
address and subnet mask, and no passwords. In this state, it can be managed
only through a direct console connection. To manage the switch through inband (networked) access, you should configure the switch with an IP address
and subnet mask compatible with your network. Also, you should configure
a Manager password to control access privileges from the console and web
browser interface. Other parameters in the Switch Setup screen can be left at
their default settings or you can configure them with values you enter.
3
Getting Started With Switch
Configuration
Many other features can be configured through the switch’s console interface,
to optimize the switch’s performance, to enhance your control of the network
traffic, and to improve network security. Once an IP address has been configured on the switch, these features can be accessed more conveniently through
a remote Telnet session, through the switch’s web browser interface, and from
an SNMP network management station running a network management
program, such as ProCurve Manager. For a listing of switch features available
with and without an IP address, refer to “How IP Addressing Affects Switch
Operation” in the Management and Configuration Guide which is on the
ProCurve Web site, www.procurve.com.
For more information on IP addressing, refer to “IP Configuration” in the
Management and Configuration Guide.
3-1
Page 48
Getting Started With Switch Configuration
NoteBy default, the switch is configured to acquire an IP address configuration
from a DHCP or Bootp server. To use DHCP/Bootp instead of the manual
method described in this chapter, see “DHCP/Bootp Operation” in the
Management and Configuration Guide which is on the ProCurve Web site,
www.procurve.com.
Using the Switch Setup Screen
The quickest and easiest way to minimally configure the switch for management and password protection in your network is to use a direct console
connection to the switch, start a console session, and access the Switch Setup
screen.
1.Using the method described in the preceding section, connect a terminal
device to the switch and display the switch console command (CLI)
prompt (the default display).
The CLI prompt appears displaying the switch model number:
ProCurve Switch 5308xl
2.At the prompt, enter the setup command to display the Switch Setup
screen. The following illustration is an example of a Setup screen with
default settings.
Configuration
Getting Started With Switch
3.Use the Tab key to select the Manager Password field and enter a manager
password of up to 16 characters.
3-2
Page 49
Getting Started With Switch Configuration
4.Tab to the IP Config (DHCP/Bootp) field and use the Space bar to select the
Manual option.
5.Tab to the IP Address field and enter the IP address that is compatible with
your network.
6.Tab to the Subnet Mask field and enter the subnet mask used for your
network.
7.Press Enter, then S (for S
ave).
The following is information on the fields in the Setup screen. For more
information on these fields, see the Management and Configuration Guide
which is on the ProCurve Web site, www.procurve.com:
ParameterDefault
System NameblankOptional; up to 25 characters, including spaces
System ContactblankOptional; up to 48 characters, including spaces
Manager PasswordblankRecommended; up to 16 characters (no blank spaces)
Logon DefaultCLIThe default setting selects the command line interface for console access.
The alternative is the Menu interface.
Time Zone0 (none)Optional; 1440 to -1440. The number of minutes your location is to the
West (-) or East (+) of GMT.
Community NamepublicDefault setting recommended.
Spanning Tree EnabledNoDefault setting recommended unless STP is already running on your network
or the switch will be used in complex network topologies.
Default GatewayblankRecommended; Enter the IP address of the next- hop gateway node if network
traffic needs to be able to reach off-subnet destinations.
Time Sync MethodTimePOptional; The protocol the switch uses to acquire a time signal. The options
are SNTP and TimeP.
TimeP ModeDisabledSynchronizes the time kept on the switch to the TimeP server.
IP ConfigDHCP/BootpSet to Manual unless a DHCP/Bootp server is used on your network to
configure IP addressing.
IP Addressxxx.xxx.xxx.xxx Recommended; If you set IP Config to Manual, then enter an IP address
compatible with your network.
Note: The IP address and subnet mask assigned for the switch must be compatible with the IP addressing used in
your network. For more information on IP addressing, see the Management and Configuration Guide which is on the
ProCurve Web site, www.procurve.com.
Subnet Maskxxx.xxx.xxx.xxx Recommended; If you entered an IP address, then enter a subnet mask
compatible with your network.
Getting Started With Switch
Configuration
3-3
Page 50
Getting Started With Switch Configuration
Where to Go From Here
The above procedure configures your switch with a Manager password, IP
address, and subnet mask. As a result, with the proper network connections,
you can now manage the switch from a PC equipped with Telnet, a web
browser interface, or from an SNMP-based network management station
using a tool such as ProCurve Manager.
Some basic information on managing your switch is included in the next
section. For more information on the console, web browser, and SNMP
management interfaces and all the features that can be configured on the
Switch 5300xl Series, please see the Management and Configuration Guide
which is on the ProCurve Web site, www.procurve.com.
To Recover from a Lost Manager Password: If you cannot start a console session at the manager level because of a lost Manager password, you
can clear all passwords and user names by getting physical access to the
switch and pressing and holding the Clear button for a full second.
Configuration
Getting Started With Switch
3-4
Page 51
Using the IP Address for Remote Switch Management
Getting Started With Switch Configuration
Using the IP Address for Remote Switch
Management
With your Switch 5300xl Series, you can use the switch’s IP address to manage
the switch from any PC that is on the same subnet as the switch. You can use
either a Telnet session or a standard web browser to manage the switch.
Starting a Telnet Session
To access the switch through a Telnet session, follow these steps:
1.Ensure the switch is configured with an IP address and that the switch is
reachable from the PC that is running the Telnet session (for example, by
using a ping command to the switch’s IP address).
2.Start the Telnet program on a PC that is on the same subnet as the switch
and connect to the switch’s IP address.
3.You will see the copyright page and the message “Press any key to
continue”. Press a key, and you will then see the switch console command
(CLI) prompt, for example (assuming there is no password):
ProCurve Switch 5308xl#
Getting Started With Switch
Enter help or ? to see a list of commands that can be executed at the
prompt. Entering any command followed by help provides more detailed
context help information about the command. Entering any command
followed by ? displays a list of options that are available at that point in
the command entry.
Starting a Web Browser Session
Your Series 5300xl Switch can be managed through a graphical interface that
you can access from any PC or workstation on the network by running your
web browser and typing in the switch’s IP address as the URL. No additional
software installation is required to make this interface available; it is included
in the switch’s onboard software.
An example web browser interface screen is shown in the next illustration.
3-5
Configuration
Page 52
Getting Started With Switch Configuration
Using the IP Address for Remote Switch Management
For more information on using the web browser interface, please see the
Management and Configuration Guide which is on the ProCurve Web site,
www.procurve.com.
An extensive help system is also available for the web browser interface. To
access the help system though, the subnet on which the switch is installed
must have access to the internet, or ProCurve Manager needs to be installed
Configuration
on a network management station that is on the subnet.
Getting Started With Switch
3-6
Page 53
Configuring the ProCurve Access Controller xl Module (J8162A)
Getting Started With Switch Configuration
Configuring the ProCurve Access
Controller xl Module (J8162A)
Before beginning the configuration, backup current configurations of all
devices. The Access Control Serer (740wl) and the Integrated Access Manager
(760wl) software must be updated to version 4.1.3.x or later and the 5300xl
switch software must be updated to version E.09.2x or later.
There are three phases of configuration:
■configuration of the 740wl/760wl
■configuration of the module
■configuration of the 5300xl switch
740wl/760wl Configuration
HP recommends the use of a static IP address for the 740wl/760wl. If the IP
address of the 740wl/760wl should change, access controller xl modules and
720wl Access Controllers would need to be reconfigured. Record this information, you will need it to configure the module. You also need to configure
a shared secret on the 740wl/760wl. Refer to the documentation that came
with that unit.
Module Configuration
Getting Started With Switch
Configuration
Once the module has been installed into the 5300xl switch you need to
configure it to enable communication with the 740wl/760wl. The module
requires an IP address. By default the module uses DHCP to obtain an IP
address. ProCurve recommends using DHCP to configure the module’s IP
address. If you need to configure a specific IP address for the module, do the
following:
From the CLI command prompt at the global configuration level
ProCurve Switch 5308xl (config) #
enter access-controller<slot ID>
where <slot ID> is the slot letter (A-H) where the module is installed.
To configure the module’s IP address
enter ip address <IP> <mask>
where <IP> is the selected address and <mask> is the selected mask. CIDR
notation “/mask bit number” (for example 10.1.1.1/24) is an acceptable
shortcut for the IP address mask combination.
3-7
Page 54
Getting Started With Switch Configuration
Configuring the ProCurve Access Controller xl Module (J8162A)
Next, configure the module with the IP address of the 740wl/760wl and its
shared secret.
access-control-server ip <ip address> secret <shared secret> <shared secret>
The shared secret and IP address here are what you configured on the 740wl/
760wl above. You enter the shared secret twice to ensure you typed it correctly.
The shared secret is case sensitive. This command tells the Access Controller
xl Module where the Access Control Server (740wl) or Integrated Access
Manager (760wl) is and allows secure communication between the module
and the 740wl/760wl. The following is an example command.
access-control-server ip 13.13.13.8 secret 7734Oh 7734Oh
Wait a few moments for the module to connect to the 740wl/760wl over the
network. To confirm that the module has connected successfully, enter the
following command:
show status
Uptime: 23 hrs, 12 mins
Access Controller Function
Access Control Server: 13.13.13.8
Connected: 2 secs
Active Clients: None
When the connection is complete between the 740wl/760wl and the Access
Controller xl Module, control of the module is turned over to the 740wl/760wl.
For more information on managing the module, see the documentation that
came with the 740wl/760wl.
For more information on the console, web browser, and SNMP management
Configuration
interfaces and all the features that can be configured on the Switch 5300xl
Series, please see the Management and Configuration Guide on the
ProCurve Web site, www.procurve.com. For the latest version you can also visit
Getting Started With Switch
the ProCurve networking products Web site www.procurve.com.
3-8
Page 55
Configuring the ProCurve Access Controller xl Module (J8162A)
Getting Started With Switch Configuration
5300xl Switch Configuration
Configuring the switch consists of assigning switch ports as client downlink
ports and reviewing the uplink VLAN used by the module. The client downlink
ports connect the module to clients, for example, access points. The uplink
VLAN connects the module to the rest of the network and the 740wl/760wl.
By default, it is assigned to the default_VLAN.
To configure client downlink ports, from the CLI command prompt at the
global configuration level
ProCurve Switch 5308xl (config) #
enter access-controller<slot ID> client-ports <port list>
where <slot ID> is the slot letter where the module is installed.
where <port list> is the port(s) to be used as client downlink ports.
Each client downlink port is assigned to a separate, automatically created
VLAN.
NoteIf a port is already assigned to an untagged VLAN, it is reassigned as an
untagged member of the new VLAN. If a port is a tagged member of an existing
VLAN, it joins the new VLAN as an untagged member, while retaining its
previous tagged VLAN membership.
Getting Started With Switch
If you receive a message ‘Command will take effect after saving configuration
and reboot.’ use write memory to save the configuration and reload to reboot
the switch. If you have additional client ports to configure do so now, then
save the configuration and reload the switch.
To change the uplink VLAN from the default_VLAN, enter the configuration
context for the new VLAN at the global configuration level
ProCurve Switch 5308xl (config) # vlan <vid>
assign the module’s uplink to that VLAN as an untagged member
where <slot ID> is the slot where the module is installed. For example, if the
module is in slot ‘B’ the command to assign the uplink VLAN to VLAN 3 would
be
ProCurve Switch 5308xl (vlan 3) # untagged bup
3-9
Configuration
Page 56
Getting Started With Switch Configuration
Configuring the ProCurve Access Controller xl Module (J8162A)
To confirm the uplink VLAN change, enter the following from the global
configuration level
You must assign at least one switch port to the uplink VLAN. This port must
be an untagged member of the VLAN and the VLAN must be able to reach the
740wl/760wl. The <slot-ID> up port must be a tagged member of the uplink
VLAN to carry client traffic.
For more information see the ProCurve 6400cl/5300xl/3400cl Management and Configuration Guide.
Configuration
Getting Started With Switch
3-10
Page 57
Configuring the ProCurve Wireless Edge Services xl Modules (J9001A, J9003A)
Getting Started With Switch Configuration
Configuring the ProCurve Wireless Edge
Services xl Modules (J9001A, J9003A)
Before beginning the configuration, backup the current configuration of the
switch. The 5300xl switch software must be updated to version E.10.30 or
later. The ProCurve Wireless Edge Services xl Module (J9001A) and the
ProCurve Redundant Wireless Services xl Module (J9003A) must be running
software version WS.01.03 or later.
NoteThe term ‘module’ is used in this section to refer to both the ProCurve Wireless
Edge Services xl Module (J9001A) and the ProCurve Redundant Wireless
Services xl Module (J9003A).
There are four module configuration tasks required:
■configuring an IP address for the module
■configuring VLANs on the 5300xl switch
■determining a module configuration backup process
■configuring wireless LAN services
Configuring an IP Address for the Module
By default, the module uses DHCP to get an IP address. The 5300xl switch CLI
has a command context, the wireless services context (accessed from the
CLI’s config context), for configuring and managing a module.
Getting Started With Switch
Configuration
Note‘ProCurve’ is used here as a generic prompt for all 5300xl switches.
To show the module’s IP address, first enter the CLI config context on the
5300xl switch, then enter the following command to access the module’s
wireless services CLI context for the module:
ProCurve (config)# wireless-services <slot-id>
where <slot-id> is the slot in the 5300xl where the module is installed.
To display the module’s IP address, enter:
ProCurve (wireless-services-id)# show ip interfaces
3-11
Page 58
Getting Started With Switch Configuration
Configuring the ProCurve Wireless Edge Services xl Modules (J9001A, J9003A)
The following example enters the wireless services context of a module
installed in Slot B of a 5300xl switch and then displays the IP address assigned
by DHCP to the module:
ProCurve# configure
ProCurve(config)# wireless-services b
ProCurve(wireless-services-B)#show ip interface
Interface IP-Address Status Protocol
vlan1 10.35.12.24(DHCP) up up
ProCurve(wireless-services-B)#
If no DHCP service is available or if the administrator wishes to manually set
the Wireless Edge Services xl Module IP Address, it can be specified using the
CLI. From the wireless services context, enter the config context and then
configure the vlan1 interface. Use the following command to set the IP address:
ProCurve(wireless-services-<slot-id>)(config-if)# ip address <IP>
where <slot-id> is the slot in the 5300xl where the module is installed.
where <IP> is the IP address in CIDR notation (/mask bit number) or
dhcp which uses a DHCP client to obtain an IP address.
In the following example, the CLI commands set the module’s IP address to
10.245.22.14 with a 21-bit subnet mask.
ProCurve(wireless-services-B)#configure
ProCurve(wireless-services-B)(config)#interface vlan1
ProCurve(wireless-services-B)(config-if)#ip address 10.245.22.14/21
ProCurve(wireless-services-B)(config-if)#show ip interface
Interface IP-Address Status Protocol
Configuration
vlan1 10.245.22.14 up up
ProCurve(wireless-services-B)(config-if)#
Getting Started With Switch
If necessary, use the following command from the wireless services config
context to set or change the default gateway:
where <ip-addr> is the numeric IP address of the default gateway, for
example 10.1.2.1.
3-12
Page 59
Configuring the ProCurve Wireless Edge Services xl Modules (J9001A, J9003A)
Getting Started With Switch Configuration
Configuring VLANs on the 5300xl Switch
In a wireless services-enabled 5300xl switch, the Wireless Edge Services xl
Module and the Redundant Wireless Services xl Module use ports on the
switch to pass wired and wireless traffic to and from the network. An uplink
VLAN, containing the module’s uplink port, communicates with the wired side
of the network; downlink radio port VLANs, containing the module’s downlink
port, communicate with the wireless side of the network.
See the Wireless Edge Services xl Module Supplement to the ProCurve 6400cl/5300xl/3400cl Management and Configuration Guide for detailed information on the set up and configuration of VLANs for module communication.
Determining a Module Configuration Backup Process
The module’s configuration files are stored on the module, not on the 5300xl
switch, unlike other 5300xl modules. An external FTP or TFTP server must be
used to back up and restore a module’s complete configuration.
The switch does save a small subset of the module’s configuration that allows
the switch to locate the full configuration file on the external FTP or TFTP
server and to validate it using a checksum. The stored subset of a module’s
configuration file appears in a show running-config or show config command
as uneditable text.
Getting Started With Switch
For more information on configuring and managing configuration files on an
external FTP or TFTP server see the ProCurve Wireless Edge Services xl Modules Management and Configuration Guide.
Configuring Wireless LAN Services
To configure wireless LAN services on a wireless services-enabled 5300xl
switch use one of the following management interfaces for the module:
■Web browser interface—Accessed through a Web browser, this intu-
itive interface provides comprehensive information to help you
manage and monitor your company’s wireless services. The menus
and online help guide you through configuration steps. See the
ProCurve Wireless Edge Services xl Modules Management and
Configuration Guide for information on using the Web browser
interface to configure and manage a module.
3-13
Configuration
Page 60
Getting Started With Switch Configuration
Configuring the ProCurve Wireless Edge Services xl Modules (J9001A, J9003A)
To run the Web browser interface for the ProCurve Wireless Edge Services
xl Module, your workstation must be running Java Virtual Machine (JVM).
If your workstation is not running the JVM and you attempt to open the
module’s Web browser interface, the workstation will automatically try to
access the Internet and download the JVM.
■Command line interface (CLI)—Available through a serial, Telnet, or
Secure Shell (SSH) session to the 5300xl switch, the wireless services
context, accessed from the 5300xl’s CLI config context, provides a
complete set of commands to configure, manage, and troubleshoot
your wireless services.
The CLI commands available in the wireless services context of the 5300xl
CLI are documented in an appendix of the ProCurve Wireless Edge Services xl Modules Management and Configuration Guide. Refer to this
manual for more information.
Because the Web browser interface simplifies both management and configuration tasks, this interface is recommended.
Configuration
Getting Started With Switch
3-14
Page 61
Troubleshooting
This chapter describes how to troubleshoot your Switch 5300xl Series. Note
that this document describes troubleshooting mostly from a hardware
perspective. You can perform more in-depth troubleshooting using the software tools available with the switch, including the full-featured console
interface, the built-in web browser interface, and ProCurve Manager, the
SNMP-based network management tool. For more information, see the
chapter on “Troubleshooting” in the Management and Configuration Guide
that is on the ProCurve Web site, www.procurve.com.
This chapter describes the following:
■basic troubleshooting tips (page 4-1)
■diagnosing with the LEDs (page 4-4)
■Proactive Networking tools (page 4-9)
■hardware diagnostic tests (page 4-10)
■restoring the factory default configuration (page 4-12)
■downloading new code (page 4-13)
■HP Customer Support Services (page 4-13)
4
Basic Troubleshooting Tips
Most problems are caused by the following situations. Check for these items
first when starting your troubleshooting:
■Faulty or loose cables. Look for loose or obviously faulty connections.
If they appear to be OK, make sure the connections are snug. If that does
not correct the problem, try a different cable.
■Non-standard cables. Non-standard and miswired cables may cause
network collisions and other network problems, and can seriously impair
network performance. Use a new correctly-wired cable or compare your
cable to the cable in appendix B, “Switch Ports and Network Cables” for
pinouts and correct cable wiring. A category 5 cable tester is a recommended tool for every 100Base-TX and 1000Base-T network installation.
4-1
Troubleshooting
Page 62
Troubleshooting
Basic Troubleshooting Tips
■Improper Network Topologies. It is important to make sure you have
a valid network topology. Common topology faults include excessive
cable length and excessive repeater delays between end nodes. If you have
network problems after recent changes to the network, change back to
the previous topology. If you no longer experience the problems, the new
topology is probably at fault.
In addition, you should make sure that your network topology contains
no data path loops. Between any two end nodes, there should be only
one active cabling path at any time. Data path loops will cause broadcast
storms that will severely impact your network performance.
With your Switch 5300xl Series, if you wish to build redundant paths
between important nodes in your network to provide some fault tolerance, you should enable Spanning Tree Protocol support on the switch.
This ensures that only one of the redundant paths is active at any time,
thus avoiding data path loops. Spanning Tree can be enabled through the
switch console, the web browser interface, or ProCurve Manager.
The Switch 5300xl Series also support Trunking, which allows multiple
network cables to be used for a single network connection without
causing a data path loop. See the Management and Configuration Guide
that is on the ProCurve Web site, www.procurve.com for more information
on Spanning Tree and on Trunking.
■Connecting to devices that have a fixed full-duplex configuration.
The RJ-45 ports on the Switch 5300xl Series are all configured as “Auto”.
That is, when connecting to attached devices, the switch will operate in
one of two ways to determine the link speed and the communication mode
(half duplex or full duplex):
•if the connected device is also configured to Auto, the switch will
automatically negotiate both link speed and communication mode
•if the connected device has a fixed configuration, for example 100
Mbps, at half or full duplex, the switch will automatically sense the
link speed, but will default to a communication of half duplex
Because the Switch 5300xl Series behave in this way (in compliance with the IEEE 802.3 standard), if a device connected to the switch has a fixed
configuration at full duplex, the device will not connect correctly to the
switch. The result will be high error rates and very inefficient communications between the switch and the device.
Ensure that all devices connected to the Switch 5300xl Series are configured to auto negotiate, or are configured to connect at half duplex (all
Troubleshooting
hubs are configured this way, for example).
4-2
Page 63
Basic Troubleshooting Tips
Troubleshooting
If necessary though, you can modify the configuration of the ports on the
Switch 5300xl Series to match the configuration of the connected device.
Use the switch console, the web browser interface, or ProCurve Manager
to modify the port configuration.
■Check the port configuration. A port on your Series 5300xl Switch may
not be operating as you expect because it has been put into a “blocking”
state by Spanning Tree, GVRP (automatic VLANs), or LACP (automatic
trunking). (Note that the normal operation of the Spanning Tree, GVRP,
and LACP features may put the port in a blocking state.) Or, the port just
may have been configured as disabled through software.
Use the switch console to determine the port’s configuration and verify
that there is not an improper or undesired configuration of any of the
switch features that may be affecting the port. See the Management and Configuration Guide that is on the ProCurve Web site, www.procurve.com
for more information.
For more information on possible network problems and their solutions, refer
to the technical note “Troubleshooting LAN Performance and Intermittent
Connectivity Problems”, which can be found on the ProCurve Web site,
www.procurve.com, in the Information Library section.
4-3
Troubleshooting
Page 64
Troubleshooting
Diagnosing with the LEDs
Power
Off with
power cord
plugged in
Diagnosing with the LEDs
Tables 4-1 shows LED patterns on the switch and the switch modules that
indicate problem conditions.
1.Check in the table for the LED pattern you see on your switch
2.Refer to the corresponding diagnostic tip on the next few pages.
Table 4-1.LED Error Indicators
LED Pattern Indicating Problems
Diagnostic
Tips
Fault
* * *** *
Self Test
Module Status
module)
(one LED per
Power Status
(one LED per
power supply)
Fan Status
Port Link
➊
OnProlonged OnProlonged
On
OnFlashing
OnFlashing
OnFlashing
OnOffOffFlashing
OnFlashing
OnFlashing
OnFlashing
OnOffOffOff**Fast
OnOffOffOn**Off with cable
* This LED is not important for the diagnosis.
Troubleshooting
†
The flashing behavior is an on/off cycle once every 1.6 seconds, approximately.
††
The fast flashing behavior is an on/off cycle once every 0.8 seconds, approximately
†
Flashing
†
Flashing†Flashing
†
Flashing†Flashing
†
Flashing†Flashing
†
†
†
Off*Flashing
Off**Flashing
*** *
Off** *
†
†
†
†
**Never On
**On briefly,
** *
**Flashing
†
**
†
then Off
*
Flashing
connected
†
††
➋
➌
➍
➎
➏
➐
➑
➒
➓
l
4-4
Page 65
Diagnostic Tips:
Diagnosing with the LEDs
Troubleshooting
Tip
Number
➊
➋
➌
ProblemSolution
The power suppli es
installed in the
switch are not
plugged into active
AC power sources,
or the power sup ply
may have failed.
A switch hardware
failure has
occurred. All the
LEDs will stay on
indefinitely.
The switch has
experienced a
backplane failure
during self test.
1. Verify the power cord is plugged into an active power source and to the switch.
Ensure these connections are snug.
2. Try power cycling the switch by unplugging and plugging the power cord back in.
3. If the Power LED is still not on, verify the AC power source works by plugging
another device into the outlet. Or try plugging the switch into a different outlet or
try a different power cord.
If the power source and power cord are OK and this condition persists, the switch
power supply may have failed. Call your HP-authorized LAN dealer, or use the
electronic support services from HP to get assistance. See the Customer Support/
Warranty card for more information.
Try power cycling the switch. If the fault indication reoccurs, the switch may have
failed. Call your HP-authorized LAN dealer, or use the electronic support services
from HP to get assistance. See the Customer Support/Warranty card for more
information.
The failure may be just in the communications with a single module slot, or it might
be more significant. Start a console session with the switch, and at the CLI prompt
issue the command show logging. In the event log that is displayed, there will be
messages that describe the extent of the problem. If the problem is with individual
slots, the r emainder of the switch slots will be fully operational and can be used until
you get a chance to replace the switch.
If necessary to resolve the problem, contact your HP-authorized LAN dealer, or use
the electronic support services from HP to get assistance. See the Customer
Support/Warranty card for more information.
➍
The module
installed in the slot
that corresponds to
the letter that is
flashing is an
invalid module.
The fact that the Link and Mode LEDs never are lit on the module indicates that it is
a ProCurve Switch gl or vl module and should not be used in your xl switch.
Ensure you have installed an xl module in the slot. ProCurve gl and vl
modules will fit in the sl ot, but they are not compatible with your ProCurve
xl
xl switch. Check to e nsure the module has a magenta “xl module ” symbol
on it.
Remove the module from the switch and replace it with an xl module, or recover the
slot with the cover plate. You can remove and replace the module without having to
power down the switch. Call your HP-authorized LAN dealer, or use the electronic
support services from HP to get information on supported Switch xl modules. The
modules that are available as of the printing of this manual are listed on page 1-10.
Troubleshooting
4-5
Page 66
Troubleshooting
Diagnosing with the LEDs
Tip
Number
➎
ProblemSolution
The module
installed in the slot
that corresponds to
the letter that is
flashing has
experienced a self
test or initialization
fault.
The modules are all tested whenever the switch is powered on, or reset (through
the Reset button on the switch, or the Reboot or Reset options in the console or web
browser interface), and when they are hot swapped (installed when the switch is
powered on).
Since the Link and Mode LEDs on the module were lit at least briefly, that indicates
that the module did receive power from the switch, but the subsequent download
process failed. Either the module is faulty, or it is a new module type that is not yet
supported by the operating code on the switch.
As Hewlett-Packard introduces new modules for your ProCurve Switch xl, you may
have to update the switch with new operating code that supports the new module.
The documentation that came with the module will indicate which version of the
operating code is needed to support the module. The modules that are supported in
your Switch xl, as of the printing of this manual, are listed on
page 1-10 under “Switch Features”. The latest code can be downloaded from the
ProCurve Web site at www.procurve.com.
First verify the switch has a version of code that supports the module that is
indicating the fault. If the module is not one of the ones listed on page 1-10, check
the module documentation to see what version of switch code is needed. Download
the new code and retest the module.
If you have the correct code installed in the switch, try removing and reinstalling the
module. You can do this without having to power do wn the switch. When the module
is reinstalled, it will be retested automatically.
If the fault indication reoccurs, the module may have failed . Remove the module fro m
the switch and replace it with another module, or recover the slot with the cover
plate. Call your HP-authorized LAN dealer, or use the electronic support services
from HP to get assistance. See the Customer Support/Warranty card for more
information.
➏
In the slot
corresponding to
the letter that is
flashing, a module
was installed th at is
a different type
than the previously
installed module,
and the switch has
not yet been reset.
When you “hot swap” modules in the switch slots, if you install a different module
type than the one that was previously installed in the slot, you must reset the switch
so the switch processor can properly initialize and configure the new module type.
The flashing LED informs you that this change of module types has occurred. The
module will not work properly until the switch is reset.
You can reset the switch by any of these methods:
• pressing the Reset button.
• power cycling the switch.
• selecting the reset or reboot option from the console, web browser interface, or
ProCurve Manager.
Troubleshooting
4-6
Page 67
Diagnosing with the LEDs
Troubleshooting
Tip
Number
➐
➑
ProblemSolution
The network port
for which the Link
LED is flashing has
experienced a self
test or initialization
failure.
A fault condition
has been detected
on the power
supply installed in
the slot
corresponding to
the flashing
number.
During the module self test, described in tip number 4 earlier in this table, each
network port is also tested. If the port self test fails, the individual port is not usable,
but the rest of the ports on the module, which have passed their self test, will
continue to operate normally.
If the port is a mini-GBIC, verify it is one of the mini-GBICs supported by the
mini-GBIC xl Module. Unsupported mini-GBICs will be identified with this fault
condition. The supported mini-GBICs are listed in the module Installation Guide. The
mini-GBICs are also tested when they are “hot-swapped”--installed or changed
after the mini-GBIC xl Module is installed and receiving power from the switch.
To verify the port has failed, try removing and reinstalling the module, as described
in tip number 4. For the mini-GBICs, you can just remove and reinstall the
mini-GBIC with out having to remove the module. If the port fault indication reo ccurs,
and you need to be able to use the port, you will have to replace the mini-GBIC or
the module. In the mean time, all the other module ports will operate normally.
Try removing and reinstalling the power supply.
Caution: Ensure the AC power cord is disconnec ted from the supply bef ore removing
and reinstalling the supply.
Reconnect the power supply to the AC powe r source. If the error indication reoccurs
after the supply is reinstalled, the power supply may be faulty. Call your HPauthorized LAN dealer, or use the electronic support services from HP to get
assistance. See the Customer Support/Warranty card for more information.
➒
➓
One or more of the
switch cooling fans
may have failed.
The network port
for which the Link
LED is flashing has
been disabled
because port
security has been
configured on the
switch and a
security violation
has been detected
on the port.
Try disconnecting power from the switch and wait a few moments. Then reconnect
the power to the switch and check the LEDs again. If the error indication reoccurs,
one or more of the fans has failed. The switch has multiple fans and may continue
to operate OK under this condition if the ambient temperature does not exceed
normal room temperature, but for best operation, the switch should be replaced.
Contact your HP-authorized LAN dealer, or use the electronic support services from
HP to get assistance. See the Customer Support/Warranty card for more
information.
For the Port Security feature, you can configure the switch so that whenever a
security violation is detected on a port, the switch will disable the port. When a port
is disabled by this feature, the port Link LED will be continuously flashed at the fast
rate of 0.8 seconds per cycle. The flashing continues until you clear the security
violation through the switch console. In the console, you can view the identity of the
connected device that committed the security violation.
Once the security violation is cleared, you must re-enable the port through the
console.
For more information on the Port Security feature, see the Management and Configuration Guide that is on the ProCurve Web site, www.procurve.com.
Troubleshooting
4-7
Page 68
Troubleshooting
Diagnosing with the LEDs
Tip
Number
l
ProblemSolution
The network
connection is not
working properly.
Try the following procedures:
• For the indicated port, verify both ends of the cabling, at the switch and the
connected device, are securely connected.
• Verify the connected device and switch are both powered on and operating
correctly.
• Verify you have used the correct cable type for the connection.
– for any of the twisted-pair connections, in the default configuration (Auto),
either a straight-through or a crossover cable can be used and the switch will
automatically adjust its operation. See the “HP Auto-MDIX Feature”
description on page B-4 for more information.
Note: If the module configuration is changed to one of the fixed
configuration options though (for example, 100-Full Duplex), then the port
operates as MDI-X only and the correct type of cable must be used. in
general, for connecting to an end node (MDI port), use straight-through
cable; for connecting to MDI-X ports on hubs, other switches, and routers,
use crossover cable.
– for fiber-optic connections, verify that the transmit port on the switch is
connected to the receive port on the connected device, and the switch
receive port is connected to the transmit port on the connected device, and
that both devices are transmitting correctly.
• For a 1000 Mbps connection, verify the network cabling complies with the IEEE
802.3ab standard. The cable should be installed according to the ANSI/TIA/EIA568-A-5 specifications. Cable testing should comply with the stated limitations
for Attenuation, Near-End Crosstalk, Far-End Crosstalk, Equal-Level Far-End
Crosstalk (ELFEXT), Multiple Disturber ELFEXT, and Return Loss.
The cable verification must include all patch cables from any end devices,
including the switch, to any patch panels in the cabling path.
• Verify the port has not been disabled through a switch configuration change.
You can use the console interface, or, if you have configured an IP address on
the switch, use the web browser interface, or ProCurve Manager network
management software to determine the state of the port and re-enable the port
if necessary.
• Verify the switch port configuration matches the configuration of the attached
device. For example, if the switch port is configured as “Auto”, the port on the
attached device al so MUST be configured as “Auto”. Depend ing on the port type,
twisted-pair or fiber-optic, if the configurations don’t match, the results could be
a very unreliable connection, or no link at all.
If the other procedures don’t resolve the problem, try using a different port or a
different cable.
Troubleshooting
4-8
Page 69
Troubleshooting
Proactive Networking
Proactive Networking
The Switch 5300xl Series have built-in management capabilities that
proactively help you manage your network including:
■finding and helping you fix the most common network error conditions
(for example, faulty network cabling, and non-standard network
topologies)
■informing you of the problem with clear, easy-to-understand messages
■recommending network configuration changes to enhance the
performance of your network
The following interfaces provide tests, indicators, and an event log that can
be used to monitor the switch and its network connections, and to help you
take advantage of these proactive networking features:
■ProCurve Manager - an SNMP-based network management tool included
with your switch
■A graphical web browser interface you can use to manage your switch
from a PC that is running a supported web browser, for example Microsoft
Internet Explorer or Netscape Communicator.
■A full-featured easy-to-use console interface you can access by merely
connecting a standard terminal or PC running a terminal emulator to the
switch’s console port. The cable to make that connection is provided with
your switch. The console interface is also accessible through a telnet
connection.
See the “Troubleshooting” chapter in the Management and Configuration Guide that is on the ProCurve Web site, www.procurve.com, for more informa-
tion on using these software tools to diagnose and manage your switch.
4-9
Troubleshooting
Page 70
Troubleshooting
Hardware Diagnostic Tests
Hardware Diagnostic Tests
Testing the Switch by Resetting It
If you believe that the switch is not operating correctly, you can reset the
switch to test its circuitry and operating code. To reset a switch, either:
■Unplug and plug in the power cord (power cycling)
■Press the Reset button on the front of the switch
■Select the reset or reboot option from the console, web browser interface,
or ProCurve Manager.
Power cycling the switch, pressing the Reset button, and the software reset
or reboot options all cause the switch to perform its power-on self-test, which
almost always will resolve any temporary operational problems. These reset
processes also cause any network traffic counters to be reset to zero and cause
the System Up Time timer to reset to zero. Neither of these reset procedures
causes any changes to the switch configuration.
Checking the Switch LEDs
The self-test passes if the Fault and Self Test LEDs on the front of the switch
go off after approximately 90 to 150 seconds depending on the number and
type of modules installed in the switch. If these LEDs stay on longer than 180
seconds or begin flashing, the switch, or a module, or an individual mini-GBIC
may have to be replaced as indicated by the LEDs.
See “Diagnosing With the LEDs” on page 4-4 for information on interpreting
the LED patterns.
Checking Console Messages
Useful diagnostic messages may be displayed on the console screen when the
switch is reset. As described in chapter 2 under step 8, “Connect a Console to
the Switch”, connect a PC running a VT-100 terminal emulator program or a
standard VT-100 terminal to the switch’s Console Port and configure it to run
at 9600 baud and with the other terminal communication settings shown on
page 2-19. Then, when you reset the switch, note the messages that are
displayed.
Troubleshooting
4-10
Page 71
Hardware Diagnostic Tests
Troubleshooting
Testing Twisted-Pair Cabling
If you think the cable should work but still isn’t working, it may not be
compatible with the IEEE 802.3 Type 10Base-T, 100Base-TX, or 1000Base-T
standards, as appropriate for the switch port type that the cable is connected
to. The twisted-pair cables attached to the Switch 5300xl Series must be
compatible with these standards.To verify your cable is compatible with these
standards, use a qualified cable test device.
HP also offers a wire testing service. Contact your HP-authorized LAN dealer
or your local HP sales office for more information.
Testing Switch-to-Device Network Communications
You can perform the following communication tests to verify the network is
operating correctly between the switch and any connected device that can
respond correctly to the communication test.
■Link Test -- a physical layer test that sends IEEE 802.2 test packets to any
device identified by its MAC address
■Ping Test -- a network layer test used on IP networks that sends test
packets to any device identified by its IP address
These tests can be performed through the switch console interface from a
terminal connected to the switch or through a telnet connection, or from the
switch’s web browser interface. See the Management and Configuration Guide that is on the ProCurve Web site, www.procurve.com for more informa-
tion.
These tests can also be performed from an SNMP network management
station running a program that can manage the switch, for example, ProCurve
Manager.
Testing End-to-End Network Communications
Both the switch and the cabling can be tested by running an end-to-end
communications test -- a test that sends known data from one network device
to another through the switch. For example, if you have two PCs on the
network that have LAN adapters between which you can run a link-level test
or Ping test through the switch, you can use this test to verify the entire
communication path between the two PCs is functioning correctly. See your
LAN adapter documentation for more information on running the a link test
or Ping test.
Troubleshooting
4-11
Page 72
Troubleshooting
Restoring the Factory Default Configuration
Restoring the Factory Default
Configuration
As part of your troubleshooting process, it may become necessary to return
the switch configuration to the factory default settings. This process momentarily interrupts the switch operation, clears any password s, clears the console
event log, resets the network counters to zero, performs a complete self test,
and reboots the switch into its factory default configuration including deleting
an IP address, if one is configured.
NoteThis process removes all switch configuration changes that you have made
from the factory default settings. This includes, for example, configuration of
VLANs, spanning tree, trunks, stacking, meshing, routing, and security.
Returning the configuration of these features to their factory default settings
(usually disabling them) may result in network connectivity issues.
If the switch has a valid configuration, and you are restoring the factory default
settings for a reason other than configuration problems, you should save the
switch configuration prior to performing the factory default reset. Then, after
the reset and resolution of the original problem, you can restore the saved
configuration to the switch. For both the save and restore processes, you can
use the console copy command. See the switch Management and Configura-tion Guide that is on the ProCurve Web site, www.procurve.com on this
command.
You can restore the factory default configuration either on the switch itself or
through the switch console.
To execute the factory default reset on the switch, perform these steps:
1.Using pointed objects, simultaneously press both the Reset and Clear
buttons on the front of the switch.
2.Continue to press the Clear button while releasing the Reset button.
3.As soon as the Self Test LED begins to blink, release the Clear button.
The switch will then complete its self test and begin operating with its
configuration restored to the factory default settings.
To restore the factory default configuration using the console, execute the
Troubleshooting
4-12
erase startup config command from the console command prompt.
Page 73
Troubleshooting
Downloading New Code
Downloading New Code
When product enhancements occur for the Switch 5300xl Series, new code
can be downloaded to the switch through several methods, for product
enhancements and new features. Please see the Management and Configu-ration Guide that is on the ProCurve Web site, www.procurve.com for more
information.
The new code would be available on the ProCurve Web site,
www.procurve.com.
HP Customer Support Services
If you are still having trouble with your switch, Hewlett-Packard offers support
24 hours a day, seven days a week through the use of a number of automated
electronic services. See the Customer Support/Warranty booklet that came
with your switch for information on how to use these services to get technical
support. The ProCurve Web site, www.procurve.com also provides up-to-date
support information.
Additionally, your HP-authorized network reseller can provide you with assistance, both with services that they offer and with services offered by HP.
Before Calling Support
Before calling your networking dealer or HP Support, to make the support
process most efficient, you first should have retrieved the following information:
Information ItemInformation Location
• product identification, including the chassis,
modules, and mini-GBICs
• details about the swi tch’s status including the OS
(software) version, a copy of the switch configuration, a copy of the switch Event Log, and a
copy of the switch status and counters information
• copy of your network topology map, including
network addresses assigned to the relevant devices
the front of the switch, and on the
modules and mini-GBICs
switch console: show tech
command
your network records
4-13
Troubleshooting
Page 74
Page 75
A
Specifications
Physical
Width:44.2 cm (17.2 in)
Depth:39.0 cm (15.2 in)
Height:
• Switch 5308xl, 5372xl, 5308xl-48G
• Switch 5304xl, 5348xl, 5304xl-32G
Weight:
• Switch 5308xl
• Switch 5372xl and 5308xl-48G
• Switch 5304xl
• Switch 5348xl and 5304xl-32G
Electrical
The Switch 5300xl Series automatically adjust to any voltage between
100-127 and 200-240 volts and either 50 or 60 Hz.
Specifications
• 22.5 cm (8.7 in)
• 13.5 cm (5.2 in)
• 12.16 kg (26.80 lbs)
• 14.20 kg (31.30 lbs) – includes three Modules
• 9.91 kg (21.85 lbs)
• 11.27 kg (24.85 lbs) – includes two Modules
AC voltage:100–127 volts200–240 volts
Maximum current:8.2 A3.8 A
Frequency range:50/60 Hz50/60 Hz
Each installed J8161A module may draw 408W@50V from an external
power supply
Environmental
OperatingNon-Operating
Temperature:5°C to 40°C (41°F to 104°F)-40°C to 70°C (-40°F to 158°F)
Relative humidity:
(non-condensing)
Maximum altitude:4.6 Km (15,000 ft) 4.6 Km (15,000 ft)
15% to 80% at 40°C (104°F)15% to 90% at 65°C (149°F)
A-1
Page 76
Specifications
Acoustic
Switch 5308xl and Switch 5372xl:
Geräuschemission LwA=63.1 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Specifications
Noise Emission LwA=63.1 dB in a virtual workspace according to
DIN 45635 T.19
Switch 5304xl and Switch 5348xl:
Geräuschemission LwA=64.2 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LwA=64.2 dB in a virtual workspace according to
DIN 45635 T.19
Network Connectors
■The 10/100 Mbps RJ-45 twisted-pair ports on the 10/100-TX xl Module are
compatible with the IEEE 802.3 10Base-T and IEEE 802.3u 100Base-TX
standards.
■The 100/1000 Mbps RJ-45 twisted-pair ports on the 100/1000-T xl Module
are compatible with the IEEE 802.3u 100Base-TX and IEEE 802.3ab
1000Base-T standards.
■The 1000 Mbps fiber-optic ports on the Gigabit-SX and Gigabit-LX
mini-GBICs are compatible with the IEEE 802.3z Gigabit-SX and
Gigabit-LX standards respectively.
Safety
A-2
■EN60950 / IEC 950
■CSA 22.2 No. 950 (cUL1950)
■UL 1950 3
rd
Edition
Page 77
Switch Ports and Network Cables
This appendix includes switch connector information and network cable
information for cables that should be used with the Switch 5300xl Series,
including minimum pin-out information and specifications for twisted-pair
cables.
B
NoteIncorrectly wired cabling is the most common cause of problems for LAN
communications. It is recommended that you work with a qualified LAN cable
installer for assistance with your cabling requirements.
Switch Ports
Twisted Pair
■The RJ-45 ports on the 10/100-TX xl Module and the 100/1000-T xl
Module accept 100-ohm differential unshielded and shielded twisted-pair
cable with RJ-45 connectors as described on the next page.
Fiber-Optic
■The LC-type connector port on the Gigabit-SX mini-GBIC transmits at
850 nm wavelength, and accepts the low metal content, multimode fiberoptic cables for Gigabit-SX described on page B-3.
■The LC-type connector port on the Gigabit-LX and LH mini-GBIC
transmits at 1310 nm wavelength, and accepts the low metal content,
single-mode or multimode fiber-optic cables for Gigabit-LX described on
complying with IEEE 802.3ab 1000Base-T specifications,
fitted with RJ-45 connectors—Category 5e or better is
recommended.
(See “Note on 1000Base-T Cable Requirements”, below)
Cables
Note on 1000Base-T Cable Requirements. The Category 5 networking
cables that work for 100Base-TX connections should also work for
Switch Ports and Network
1000Base-T, as long as all four-pairs are connected. But, for the most robust
connections you should use cabling that complies with the Category 5e
specifications, as described in Addendum 5 to the TIA-568-A standard (ANSI/
TIA/EIA-568-A-5).
Because of the increased speed provided by 1000Base-T (Gigabit-T), network
cable quality is more important than for either 10Base-T or 100Base-TX. Site
cabling that is being used to carry 1000Base-T networking must comply with
the IEEE 802.3ab standards. In particular, the cabling must pass tests for
Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT).
Additionally, unlike the cables for 100Base-TX, the 1000Base-T cables must
pass tests for Equal-Level Far-End Crosstalk (ELFEXT), Multiple Disturber
ELFEXT, and Return Loss.
When testing your cabling, be sure to include the patch cables that connect
the switch and other end devices to the patch panels on your site. The patch
cables are frequently overlooked when testing cable and they must also
comply with the cabling standards.
B-2
Page 79
Switch Ports and Network Cables
Fiber-Optic Cables
Port TypeCable SpecificationsConnector TypeMaximum Length
Gigabit-SX 62.5/125 mm or 50/125 μm (core/cladding)
diameter, graded-index 850 nm, low metal
content, multimode fiber-optic cables,
complying with the ITU-T G.651 and ISO/IEC
793-2 Type A1b or A1a respectively.
index 1310 nm, low metal content, single
mode fiber-optic cables, complying with the
ITU-T G.652 and ISO/IEC 793-2 Type B1
standards.
OR
the multimode fiber-optic cables listed for
Gigabit-SX.
Note: To use multimode cables for Gigabit-LX, a mode conditioning patch cord may be needed - See the
Installation Guide that came with your module for more information.
Gigabit-LH 9/125 mm (core/cladding) diameter, graded-
index 1550 nm, low metal content, single
mode fiber-optic cables, complying with the
ITU-T G.652 and ISO/IEC 793-2 Type B1
standards.
Note: Between the transmit and receive ends of the cable, at least 5db of attenuation is required for a
reliable connection. This is equivalent to 20Km of the fiber-optic cable. For distances less than 20Km,
you must add attenuators to bring the total attenuation to at least 5db. Most cable vendors carry
attenuators.
62.5/125 μm or 50/125 μm (core/cladding)
diameter, graded-index, low metal content,
multimode fiber-optic cables, complying
with the ITU-T G.651 and ISO/IEC 793-2 Type
A1b or A1a respectively.
Gigabit Ethernet: 62.5/125 μm (core/
cladding) diame ter or 50/125 μm, 850 nm, low
metal content,
complying with the ITU-T G.652 and ISO/IEC
793-2 Type B1 standards.
MT-RJ• full-duplex connections:
SC
2 kilometers
• half-duplex connections:
412 meters
■62.5 μm cable:
•160 Mhz*km = 2-26 meters
•200 Mhz*km = 2-33 meters
■50 μm cable:
•400 Mhz*km = 2-66 meters
•500 Mhz*km = 2-82 meters
•2000 Mhz*km = 2-300
meters
B-3
Page 80
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Port TypeCable SpecificationsConnector TypeMaximum Length
(40 kilometers, on an engineered
fiber optic link that meets standards
in the specification).
1-300 meters
Cables
Copper Cables
Switch Ports and Network
Port TypeCable SpecificationsConnector
CX4Speed 3.125Gbx4
(Cables compliant with the 802.3ak standard)
Ty pe
CX40.5-15 meters
Supported Length
B-4
Twisted-Pair Cable/Connector Pin-Outs
The HP Auto-MDIX Feature. In the default configuration, “Auto”, the
10/100Base-TX ports on the 10/100-TX and PoE xl Modules used in the Switch
5300xl Series all automatically detect the type of port on the connected device
and operate as either an MDI or MDI-X port, whichever is appropriate. So for
any connection, a straight-through twisted-pair cable can be used -- you no
longer have to use crossover cables, although crossover cables can also be
used for any of the connections. The 100/1000-T xl Module supports the IEEE
802.3ab standard, which includes the “Auto MDI/MDI-X” feature, which operates the same way.
Page 81
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
NoteHP Auto-MDIX was developed and shared with the IEEE for the development
of the IEEE 802.3ab standard. HP Auto-MDIX and the IEEE 802.3ab Auto MDI/
MDI-X feature are completely compatible.
If you connect a Series 5300xl Switch twisted-pair port to another switch or
hub, which typically have MDI-X ports, the Series 5300xl Switch port automatically operates as an MDI port. If you connect it to an end node, such as a
server or PC, which typically have MDI ports, the Series 5300xl Switch port
operates as an MDI-X port. In all cases, you can use standard straight through
cables.
If you happen to use a correctly wired crossover cable, though, the switch will
still be able to automatically detect the MDI/MDI-X operation and link
correctly to the connected device.
If the port configuration is changed to any of the fixed configurations
though, for example 100 Mbps/full duplex, the port operates as MDI-X only
and the correct cable type must be used. In general, for connections to MDI
ports, such as end nodes, use a straight-through cable; for connections to MDIX ports, such as on hubs and other switches, use a crossover cable.
Other Wiring Rules:
■All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See the Pin Assignment tables
below the cable illustrations later in this appendix for a listing of the
signals used on each pin.
■For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See “Note on 1000Base-T Cable Requirements” on page B-2 for more information on 1000Base-T cabling.
■For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
100-ohm differential unshielded twisted-pair (UTP) or shielded twistedpair (STP) cable, as supported by the IEEE 802.3 10Base-T standard.
■For 100 Mbps connections to the ports, use Category 5 100-ohm differen-
tial UTP or STP cable only, as supported by the IEEE 802.3u 100Base-TX
standard.
or STP cable only, as supported by the IEEE 802.3ab 1000Base-T standard;
Category 5e or better is recommended.
Switch Ports and Network
Cables
B-5
Page 82
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Straight-Through Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connections
Because of the HP Auto-MDIX operation of the 10/100 ports on the switches,
for all network connections, to PCs, servers or other end nodes, or to hubs or
other switches, you can use straight-through cables.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and straight-through cables
must be then used for connections to PC NICs and other MDI ports.
Cable Diagram
Cables
Switch Ports and Network
NotePins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.
.
Pin Assignments
B-6
Switch End (MDI-X)Computer, Transceiver, or
SignalPinsPinsSignal
receive +
receive transmit +
transmit -
1
2
3
6
Other End
1
2
3
6
transmit +
transmit receive +
receive -
Page 83
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Crossover Twisted-Pair Cable for
10 Mbps or 100 Mbps Network Connection
The HP Auto-MDIX operation of the 10/100 ports on the switches also allows
you to use crossover cables for all network connections, to PCs, servers or
other end nodes, or to hubs or other switches.
If any of these ports are given a fixed configuration, for example 100 Mbps/
Full Duplex, the ports operate as MDI-X ports, and crossover cables must be
then used for connections to hubs or switches or other MDI-X network
devices.
Cable Diagram
NotePins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired
in the cable.
.
Pin Assignments
Switch Ports and Network
Cables
Switch End (MDI-X)Hub or Switch Port, or Other
SignalPinsPinsSignal
receive +
receive transmit +
transmit -
1
2
3
6
MDI-X Port End
6
3
2
1
transmit transmit +
receive receive +
B-7
Page 84
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Straight-Through Twisted-Pair Cable for
1000 Mbps Network Connections
1000Base-T connections require that all four pairs or wires be connected.
Cable Diagram
Cables
Switch Ports and Network
NotePins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4 and 5 on connector “A” must be wired as a twisted pair to pins 4 and 5
on connector “B”.
Pins 7 and 8 on connector “A” must be wired as a twisted pair to pins 7 and 8
on connector “B”.
.
Pin Assignments
For 1000Base-T operation, all four pairs of wires are used for both transmit
and receive.
B-8
Page 85
Safety and EMC Regulatory Statements
Safety Information
Documentation r eference symbol. If the product is marked with this
!
symbol, refer to the product documentation to get more information
about the product.
C
WARNINGA WARNING in the manual denotes a hazard that can cause injury
or death.
CautionA Caution in the manual denotes a hazard that can damage
equipment.
Do not proceed beyond a WARNING or Caution notice until you
have understood the hazardous conditions and have taken appropriate steps.
Grounding
These are safety class I products and have protective earthing terminals. There
must be an uninterruptible safety earth ground from the main power source
to the product's input wiring terminals, power cord, or supplied power cord
set. Whenever it is likely that the protection has been impaired, disconnect
the power cord until the ground has been restored.
For LAN cable grounding:
■If your LAN covers an area served by more than one power distribu-
tion system, be sure their safety grounds are securely interconnected.
■LAN cables may occasionally be subject to hazardous transient volt-
ages (such as lightning or disturbances in the electrical utilities power
grid). Handle exposed metal components of the network with
Caution.
Servicing
There are no user-serviceable parts inside these products. Any servicing,
adjustment, maintenance, or repair must be performed only by service-trained
personnel.
Safety and EMC Regulatory
Statements
These products do not have a power switch; they are powered on when the
power cord is plugged in.
C-1
Page 86
Safety and EMC Regulatory Statements
Informations concernant la sécurité
Informations concernant la sécurité
Symbole de référence à la documentation. Si le produit est marqué de
!
ce symbole, report ez-vous à la documentation du p roduit afin d'obtenir
des informations plus détaillées.
WARNINGDans la documentation, un WARNING indique un danger susceptible
CautionUn texte de mise en garde intitulé Caution indique un danger suscep-
Cet appareil est un produit de classe I et possède une borne de mise à la terre. La source
d'alimentation principale doit être munie d'une prise de terre de sécurité installée aux
bornes du câblage d'entrée, sur le cordon d'alimentation ou le cordon de raccordement
fourni avec le produit. Lorsque cette protection semble avoir été endommagée,
débrancher le cordon d'alimentation jusqu'à ce que la mise à la terre ait été réparée.
Mise à la terre du câble de réseau local:
■si votre réseau local s'étend sur une zone desservie par plus d'un système de
distribution de puissance, assurez-vous que les prises de terre de sécurité
soient convenablement interconnectées.
■Les câbles de réseaux locaux peuvent occasionnellement être soumis à des
surtensions transitoires dangereuses (telles que la foudre ou des perturbations dans le réseau d'alimentation public). Manipulez les composants
métalliques du réseau avec précautions.
d'entraîner des dommages corporels ou la mort.
tible de causer des dommages à l'équipement.
Ne continuez pas au-delà d'une rubrique WARNING ou Caution avant
d'avoir bien compris les conditions présentant un danger et pris les
mesures appropriées.
Statements
Aucune pièce contenue à l'intérieur de ce produit ne peut être réparée par l'utilisateur.
Tout dépannage, réglage, entretien ou réparation devra être confié exclusivement à un
Safety and EMC Regulatory
personnel qualifié.
C-2
Cet appareil ne comporte pas de commutateur principal ; la mise sous tension est
effectuée par branchement du cordon d'alimentation.
Page 87
Hinweise zur Sicherheit
Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem
!
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
Safety and EMC Regulatory Statements
Hinweise zur Sicherheit
WARNINGSymbol für Dokumentationsverweis. Wenn das Produkt mit diesem
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
CautionSymbol für Dokumentationsverweis. Wenn das Produkt mit diesem
Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation
nach, um mehr Informationen über das Produkt zu erhalten.
Fahren Sie nach dem Hinweis WARNING oder Caution erst fort,
nachdem Sie den Gefahrenzustand verstanden und die entsprechenden Maßnahmen ergriffen haben.
Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdungsterminal. Der Betrieb des Geräts erfordert eine ununterbrochene Sicherheitserdung
von der Hauptstromquelle zu den Geräteingabeterminals, den Netzkabeln oder dem
mit Strom belieferten Netzkabelsatz voraus. Sobald Grund zur Annahme besteht, daß
der Schutz beeinträchtigt worden ist, das Netzkabel aus der Wandsteckdose herausziehen, bis die Erdung wiederhergestellt ist.
Für LAN-Kabelerdung:
■Wenn Ihr LAN ein Gebiet umfaßt, das von mehr als einem Stromverteilungs-
system beliefert wird, müssen Sie sich vergewissern, daß die
Sicherheitserdungen fest untereinander verbunden sind.
■LAN-Kabel können gelegentlich gefährlichen Übergangsspannungen aus-
gesetzt werden (beispielsweise durch Blitz oder Störungen in dem
Starkstromnetz des Elektrizitätswerks). Bei der Handhabung exponierter
Metallbestandteile des Netzwerkes Vorsicht walten lassen.
Safety and EMC Regulatory
Statements
Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile. Wartungs-,
Anpassungs-, Instandhaltungs- oder Reparaturarbeiten dürfen nur von geschultem
Bedienungspersonal durchgeführt werden.
Dieses Gerät hat keinen Netzschalter; es wird beim Anschließen des Netzkabels
eingeschaltet.
C-3
Page 88
Safety and EMC Regulatory Statements
Considerazioni sulla sicurezza
Considerazioni sulla sicurezza
Simbolo di riferimento alla documentazione. Se il prodotto è contras-
!
segnato da questo simbolo, fare riferimento alla documentazione sul
prodotto per ulteriori informazioni su di esso.
WARNINGLa dicitura WARNING denota un pericolo che può causare lesioni o
CautionLa dicitura Caution denota un pericolo che può danneggiare le
Questo prodotto è omologato nella classe di sicurezza I ed ha un terminale protettivo
di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non
interrompibile che vada dalla fonte d'alimentazione principale ai terminali d'entrata,
al cavo d'alimentazione oppure al set cavo d'alimentazione fornito con il prodotto.
Ogniqualvolta vi sia probabilità di danneggiamento della protezione, disinserite il cavo
d'alimentazione fino a quando il collegaento a terra non sia stato ripristinato.
Per la messa a terra dei cavi LAN:
■se la vostra LAN copre un'area servita da più di un sistema di distribuzione
elettrica, accertatevi che i collegamenti a terra di sicurezza siano ben collegati
fra loro;
■i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni
transitorie (ad esempio, provocate da lampi o disturbi nella griglia d'alimen-
Statements
Safety and EMC Regulatory
tazione della società elettrica); siate cauti nel toccare parti esposte in metallo
della rete.
Nessun componente di questo prodotto può essere riparato dall'utente. Qualsiasi
lavoro di riparazione, messa a punto, manutenzione o assistenza va effettuato esclusivamente da personale specializzato.
morte.
attrezzature.
Non procedere oltre un avviso di WARNING o di Caution prima di
aver compreso le condizioni di risc hio e aver provveduto alle misure
del caso.
C-4
Questo apparato non possiede un commutatore principale; si mette scotto tensione
all'inserirsi il cavo d'alimentazione.
Page 89
Safety and EMC Regulatory Statements
Consideraciones sobre seguridad
Consideraciones sobre seguridad
Símbolo de referencia a la documentación. Si el producto va
!
marcado con este símbolo, consultar la documentación del
producto a fin de obtener mayor información sobre el producto.
WARNINGUna WARNING en la documentación señala un riesgo que podría
resultar en lesiones o la muerte.
CautionUna Caution en la documentación señala un riesgo que podría
resultar en averías al equipo.
No proseguir después de un símbolo de WARNING o Caution hasta
no haber entendido las condiciones peligrosas y haber tomado las
medidas apropiadas.
Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por
una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde
la toma de alimentación eléctrica hasta las bornas de los cables de entrada del aparato,
el cable de alimentación o el juego de cable de alimentación suministrado. Si existe la
probabilidad de que la protección a tierra haya sufrido desperfectos, desenchufar el
cable de alimentación hasta haberse subsanado el problema.
Puesta a tierra del cable de la red local (LAN):
■Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una
red de distribución de electricidad, cerciorarse de que las puestas a tierra
estén conectadas entre sí de modo seguro.
■Es posible que los cables de la LAN se vean sometidos de vez en cuando a
voltajes momentáneos que entrañen peligro (rayos o alteraciones en la red
de energía eléctrica). Manejar con precaución los componentes de metal de
la LAN que estén al descubierto.
Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario.
Todas las reparaciones, ajustes o servicio de mantenimiento debe realizarlos solamente el técnico.
Safety and EMC Regulatory
Statements
Este producto no tiene interruptor de potencia; se activa cuando se enchufa el cable
de alimentación.
C-5
Page 90
Safety and EMC Regulatory Statements
Safety Information (Japan)
Safety Information (Japan)
Statements
Safety and EMC Regulatory
Japan Power
Cord Warning
C-6
Page 91
Safety and EMC Regulatory Statements
Safety Information (China)
Safety Information (China)
C-7
Safety and EMC Regulatory
Statements
Page 92
Safety and EMC Regulatory Statements
EMC Regulatory Statements
EMC Regulatory Statements
U.S.A.
FCC Class A
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause interference to
radio communications. Operation of this equipment in a residential area may
cause interference in which case the user will be required to correct the
interference at his own expense.
Canada
This product complies with Class A Canadian EMC requirements.
Australia/New Zealand
This product complies with Australia/New Zealand EMC Class A
requirements.
Statements
Japan
Safety and EMC Regulatory
C-8
VCCI Class A
Page 93
Korea
Taiwan
Safety and EMC Regulatory Statements
EMC Regulatory Statements
Regulatory Model Identification Number
For regulatory identification purposes, the ProCurve
Switch 5300xl Series are assigned a Regulatory Model
Number. The Regulatory Model Number for these switches
is RSVLC-0202.
This regulatory number should not be confused with the
marketing name (ProCurve Switch 5300xl Series), or
product numbers (J4819A, J4848A, J4849B, J4850A)
conforms to the following Product Specifications and regulations:
EMC: Class A
EN 55022:1998 +A1:2001 +A2:2002
EN 55024:1998 +A1+A2
EN 61000-3-2:2000 +A2:2005
EN 61000-3-3:1995 +A1:2001
FCC CFR47 Part 15
2
: HP ProCurve Switch 5304xl, 5308xl, 5348xl (bundle)
DECLARATION OF CONFORMITY
according to ISO/IEC 17050-1 and EN17050-1
1
: RSVLC-0202
Safety:
EN 60950-1:2001 / IEC 60950-1:2001
EN 60825-1:1994 +A1+A2 / IEC 60825-1:1993 +A2 Class 1
Statements
Safety and EMC Regulatory
The device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
The product herewith complies with the requirements of the Low Voltage Directive 2006/95/EC,
the EMC Directive 2004/108/EC and carries the CE marking accordingly.
Additional Information:
1) This product is assigned a Regulatory Model Number which stays with the regulatory aspects of the design. The
Regulatory Model Number is that main product identifier in the regulatory documentation and test reports, this
number should not be confused with the marketing name or the product numbers.
2) This product was tested with HP branded products only.
Roseville, 22 January 2008
European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department HQTRE, Herrenberger Straße 140, D-71034 Böblingen (FAX: + 49-7031-14-3143)
C-10
Page 95
Recycle Statements
Waste Electrical and Electronic
Equipment (WEEE) Statements
Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with
your other household waste. Instead, it is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the recycling of waste electrical and electronic
equipment. The separate collection and recycling of your waste equipment at the time of disposal will
help to conserve natural resources and ensure that it is recycled in a manner that protects human health
and the environment. For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal service or the shop where
you purchased the product.
Likvidace zařízení soukromými domácími uživateli v Evropské unii
Tento symbol na produktu nebo balení označuje výrobek, který nesmí být vyhozen spolu s ostatním
domácím odpadem. Povinností uživatele je předat takto označený odpad na předem určené sběrné
místo pro recyklaci elektrických a elektronických zařízení. Okamžité třídění a recyklace odpadu
pomůže uchovat přírodní prostředí a zajistí takový způsob recyklace, který ochrání zdraví a životní
prostředí člověka. Další informace o možnostech odevzdání odpadu k recyklaci získáte na
příslušném obecním nebo městském úřadě, od firmy zabývající se sběrem a svozem odpadu nebo v
obchodě, kde jste produkt zakoupili.
D
Bortskaffelse af affald fra husstande i den Europæiske Union
Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det, at produktet ikke må
bortskaffes med andet almindeligt husholdningsaffald. I stedet er det dit ansvar at bortskaffe kasseret
udstyr ved at aflevere det på den kommunale genbrugsstation, der forestår genvinding af kasseret
elektrisk og elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr i forbindelse
med bortskaffelsen bidrager til bevarelse af naturlige ressourcer og sikrer, at udstyret genvindes på en
måde, der beskytter både mennesker og miljø. Yderligere oplysninger om, hvor du kan aflevere kasseret
udstyr til genvinding, kan du få hos kommunen, den lokale genbrugsstation eller i den butik, hvor du købte
produktet.
Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus
See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi koos teiste majapidamisjäätmetega kõrvaldada. Teie kohus on oma seadmete jäätmed kõrvaldada, viies need elektri- ja elektroonikaseadmete jäätmete ringlussevõtmiseks selleks ettenähtud kogumispunkti. Seadmete jäätmete eraldi
kogumine ja ringlussevõtmine kõrvaldamise ajal aitab kaitsta loodusvarasid ning tagada, et ringlussevõtmine toimub viisil, mis kaitseb inimeste tervist ning keskkonda. Lisateabe saamiseks selle kohta, kuhu
oma seadmete jäätmed ringlussevõtmiseks viia, võtke palun ühendust oma kohaliku linnakantselei,
majapidamisjäätmete kõrvaldamise teenistuse või kauplusega, kust Te toote ostsite.
D-1
Recycle Statements
Page 96
Recycle Statements
Έ
A
A
Waste Electrical and Electronic Equipment (WEEE) Statements
Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella
Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää kotitalousjätteiden mukana.
Tällöin hävitettävä laite on toimitettava sähkölaitteiden ja elektronisten laitteiden kierrätyspisteeseen.
Hävitettävien laitteiden erillinen käsittely ja kierrätys auttavat säästämään luonnonvaroja ja
varmistamaan, että laite kierrätetään tavalla, joka estää terveyshaitat ja suojelee luontoa. Lisätietoja
paikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla yhteyttä jätehuoltoon tai
liikkeeseen, josta tuote on ostettu.
Élimination des appareils mis au rebut par les ménages dans l'Union européenne
Le symbole apposé sur ce produit ou sur son emballage indique que ce produit ne doit pas être jeté avec
les déchets ménagers ordinaires. Il est de votre responsabilité de mettre au rebut vos appareils en les
déposant dans les centres de collecte publique désignés pour le recyclage des équipements électriques
et électroniques. La collecte et le recyclage de vos appareils mis au rebut indépendamment du reste
des déchets contribue à la préservation des ressources naturelles et garantit que ces appareils seront
recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus d'informations
sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités
locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous
avez acheté ce produit.
Entsorgung von Altgeräten aus privaten Haushalten in der EU
Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass das Produkt nicht über den
normalen Hausmüll entsorgt werden darf. Benutzer sind verpflichtet, die Altgeräte an einer Rücknahmestelle für Elektro- und Elektronik-Altgeräte abzugeben. Die getrennte Sammlung und ordnungsgemäße Entsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert
eine Wiederverwertung, die die Gesundheit des Menschen und die Umwelt sc hützt. Informationen dazu,
wo Sie Rücknahmestellen für Ihre Altgeräte finden, erhalten Sie bei Ihrer Stadtverwaltung, den örtlichen
Müllentsorgungsbetrieben oder im Geschäft, in dem Sie das Gerät erworben haben
Απόρριψη άχρηστου εξοπλισμού από χρήστες σε ιδιωτικά νοικοκυριά στην Ευρωπαϊκή
νωση
Το σύμβολο αυτό στο προϊόν ή τη συσκευασία του υποδεικνύει ότι το συγκεκριμένο προϊόν δεν
πρέπει να διατίθεται μαζί με τα άλλα οικιακά σας απορρίμματα. Αντίθετα, είναι δική σας ευθύνη να
απορρίψετε τον άχρηστο εξοπλισμό σας παραδίδοντάς τον σε καθορισμένο σημείο συλλογής για την
ανακύκλωση άχρηστου ηλεκτρικού και ηλεκτρονικού εξοπλισμού
ανακύκλωση του άχρηστου εξοπλισμού σας κατά την απόρριψη θα συμβάλει στη διατήρηση των
φυσικών πόρων και θα διασφαλίσει ότι η ανακύκλωση γίνεται με τρόπο που προστατεύει την
ανθρώπινη υγεία και το περιβάλλον. Για περισσότερες πληροφορίες σχετικά με το πού μπορείτε να
παραδώσετε τον άχρηστο εξοπλισμό σας
γραφείο, την τοπική υπηρεσία διάθεσης οικιακών απορριμμάτων ή το κατάστημα όπου αγοράσατε το
προϊόν.
Készülékek magánháztartásban történő selejtezése az Európai Unió területén
készüléken, illetve a készülék csomagolásán látható azonos szimbólum annak jelzésére szolgál,
hogy a készülék a selejtezés során az egyéb háztartási hulladéktól eltérő módon kezelendő. A
vásárló a hulladékká vált készüléket köteles a kijelölt gyűjtőhelyre szállítani az elektromos és
elektronikai készülékek újrahasznosítása céljából. A hulladékká vált készülékek selejtezéskori
begyűjtése és újrahasznosítása hozzájárul a természeti erőforrások megőrzéséhez, valamint
biztosítja a selejtezett termékek környezetre és emberi egészségre nézve biztonságos feldolgozását.
begyűjtés pontos helyéről bővebb tájékoztatást a lakhelye szerint illetékes önkormányzattól, az
Recycle Statements
illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat.
γιαανακύκλωση, επικοινωνήστεμετοαρμόδιοτοπικό
. Η ξεχωριστή συλλογή και
D-2
Page 97
Waste Electrical and Electronic Equipment (WEEE) Statements
A
V
Recycle Statements
Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea
Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere
smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature consegnandole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed
elettroniche. La raccolta differenziata e il corretto riciclo delle apparecchiature da smaltire permette di
proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative ai punti di raccolta
delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il
quale è stato acquistato il prodotto.
Nolietotu iekārtu iznīcināšanas noteikumi lietotājiem Eiropas Savienības privātajās
mājsaimniecībās
Šāds simbols uz izstrādājuma vai uz tā iesaiņojuma norāda, ka šo izstrādājumu nedrīkst izmest kopā ar
citiem sadzīves atkritumiem. Jūs atbildat par to, lai nolietotās iekārtas tiktu nodotas speciāli iekārtotos
punktos, kas paredzēti izmantoto elektrisko un elektronisko iekārtu savākšanai otrreizējai pārstrādei.
tsevišķa nolietoto iekārtu savākšana un otrreizējā pārstrāde palīdzēs saglabāt dabas resursus un
garantēs, ka šīs iekārtas tiks otrreizēji pārstrādātas tādā veidā, lai pasargātu vidi un cilvēku veselību.
Lai uzzinātu, kur nolietotās iekārtas var izmest otrreizējai pārstrādei, jāvēršas savas dzīves vietas
pašvaldībā, sadzīves atkritumu savākšanas dienestā vai veikalā, kurā izstrādājums tika nopirkts.
artotojų iš privačių namų ūkių įrangos atliekų šalinimas Europos Sąjungoje
Šis simbolis ant gaminio arba jo pakuotės rodo, kad šio gaminio šalinti kartu su kitomis namų ūkio
atliekomis negalima. Šalintinas įrangos atliekas privalote pristatyti į specialią surinkimo vietą elektros ir
elektroninės įrangos atliekoms perdirbti. Atskirai surenkamos ir perdirbamos šalintinos įrangos atliekos
padės saugoti gamtinius išteklius ir užtikrinti, kad jos bus perdirbtos tokiu būdu, kuris nekenkia žmonių
sveikatai ir aplinkai. Jeigu norite sužinoti daugiau apie tai, kur galima pristatyti perdirbtinas įrangos
atliekas, kreipkitės į savo seniūniją, namų ūkio atliekų šalinimo tarnybą arba parduotuvę, kurioje
įsigijote gaminį.
Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie
Dit symbool op het product of de verpakking geeft aan dat dit product niet mag worden gedeponeerd bij
het normale huishoudelijke afval. U bent zelf verantwoordelijk voor het inleveren van uw afgedankte
apparatuur bij een inzamelingspunt voor het recyclen van oude elektrisch e en elektronische apparatuur.
Door uw oude apparatuur apart aan te bieden en te recyclen, kunnen natuurlijke bronnen worden
behouden en kan het materiaal worden hergebruikt op een manier waarmee de volksgezondheid en het
milieu worden beschermd. Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel
waar u het product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur
kunt aanbieden voor recycling.
Pozbywanie się zużytego sprzętu przez użytkowników w prywatnych gospodarstwach
domowych w Unii Europejskiej
Ten symbol na produkcie lub jego opakowaniu oznacza, że produktu nie wolno wyrzucać do zwykłych
pojemników na śmieci. Obowiązkiem użytkownika jest przekazanie zużytego sprzętu do
wyznaczonego punktu zbiórki w celu recyklingu odpadów powstałych ze sprzętu elektrycznego i
elektronicznego. Osobna zbiórka oraz recykling zużytego sprzętu pomogą w ochronie zasobów
naturalnych i zapewnią ponowne wprowadzenie go do obiegu w sposób chroniący zdrowie człowieka
i środowisko. Aby uzyskać więcej informacji o tym, gdzie można przekazać zużyty sprzęt do
recyklingu, należy się skontaktować z urzędem miasta, zakładem gospodarki odpadami lub sklepem,
w którym zakupiono produkt.
Recycle Statements
D-3
Page 98
Recycle Statements
Waste Electrical and Electronic Equipment (WEEE) Statements
Descarte de Lixo Elétrico na Comunidade Européia
Este símbolo encontrado no produto ou na embalagem indica que o produto não deve ser descartado
no lixo doméstico comum. É responsabilidade do cliente descartar o material usado (lixo elétrico),
encaminhando-o para um ponto de coleta para reciclagem. A coleta e a reciclagem seletivas desse
tipo de lixo ajudarão a conservar as reservas naturais; sendo assim, a reciclagem será feita de uma
forma segura, protegendo o ambiente e a saúde das pessoas. Para obter mais informações sobre locais
que reciclam ess e tipo de material, entre e m contato com o escritório da HP em sua cidade, com o s erviço
de coleta de lixo ou com a loja em que o produto foi adquirido.
Likvidácia vyradených zariadení v domácnostiach v Európskej únii
Symbol na výrobku alebo jeho balení označuje, že daný výrobok sa nesmie likvidovať s domovým
odpadom. Povinnosťou spotrebiteľa je odovzdať vyradené zariadenie v zbernom mieste, ktoré je
určené na recykláciu vyradených elektrických a elektronických zariadení. Separovaný zber a
recyklácia vyradených zariadení prispieva k ochrane prírodných zdrojov a zabezpečuje, že recyklácia
sa vykonáva spôsobom chrániacim ľudské zdravie a životné prostredie. Informácie o zberných
miestach na recykláciu vyradených zariadení vám poskytne miestne zastupiteľstvo, spoločnosť
zabezpečujúca odvoz domového odpadu alebo obchod, v ktorom ste si výrobok zakúpili.
Odstranjevanje odslužene opreme uporabnikov v zasebnih gospodinjstvih v Evropski uniji
Ta znak na izdelku ali njegovi embalaži pomeni, da izdelka ne smete odvreči med gospodinjske
odpadke. Nasprotno, odsluženo opremo morate predati na zbirališče, pooblaščeno za recikliranje
odslužene električne in elektronske opreme. Ločeno zbiranje in recikliranje odslužene opreme
prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv
način. Za podrobnejše informacije o tem, kam lahko odpeljete odsluženo opremo na recikliranje, se
obrnite na pristojni organ, komunalno službo ali trgovino, kjer ste izdelek kupili.
Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la
Unión Europea
Este símbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios
generales de la casa. Es responsabilidad del usuario eliminar los residuos de este tipo depositándolos
en un "punto limpio" para el reciclado de residuos eléctricos y electrónicos. La recogida y el reciclado
selectivos de los residuos de aparatos eléctricos en el momento de su eliminación contribuirá a
conservar los recursos naturales y a garantizar el reciclado de estos residuos de forma que se proteja
el medio ambiente y la salud. Para obtener más información sobre los puntos de recogida de residuos
eléctricos y electrónicos para reciclado, póngase en contacto con su ayuntamiento, con el servicio de
eliminación de residuos domésticos o con el establecimiento en el que adquirió el producto.
Bortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen
Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får
slängas på samma ställe som hushållssopor. I stället är det ditt ansvar att bortskaffa avfallet genom att
överlämna det till ett uppsamlingsställe avsett för återvinning av avfall från elektriska och elektroniska
produkter. Separat insamling och återvinning av avfallet hjälper till att spara på våra naturresurser och
gör att avfallet återvinns på ett sätt som skyddar människors hälsa och miljön. Kontakta ditt lokala
kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten
för att få mer information om var du kan lämna ditt avfall för återvinning.
Recycle Statements
D-4
Page 99
Index
Symbols
! (attention) LED … 1-7
Numerics
100/1000Base-T
connections, length limitations … 2-6
note on cable requirements … B-2
ports, cables used with … 2-6, B-2
twisted-pair cable specifications … B-2
1000Base-LH
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-LX
connections, length limitations … 2-6
ports, cables used with … 2-6
1000Base-SX
connections, length limitations … 2-6
ports, cables used with … 2-6
100Base-TX
ports, cables used with … B-2
twisted-pair cable specifications … B-2
10Base-T
ports, cables used with … B-2
twisted-pair cable specifications … B-2
A
Act LED … 1-6
aggregation switch, example topology as … 2-25
auto MDI/MDI-X operation … B-6, B-8
HP Auto-MDIX feature … B-4
B
back of switch
description … 1-9
power connector … 1-9
slot for redundant power supply … 1-9
basic connectivity, example topology … 2-22
basic switch configuration