HP J4093A, J4120A Installation Manual

Page 1
HP ProCurve Switches and Hubs
HP ProCurve Switch 1600M and 2424M Installation Guide
Less Work, More Network
http://www.hp.com/go/procurve
Page 2
Page 3
HP ProCurve Switch 1600M and 2424M
Page 4
© Copyright 1998 Hewlett-Packard Company All Rights Reserved.
This document contains information which is protected by copyright. Reproduction, adaptation, or translation without prior permission is prohibited, except as allowed under the copyright laws.
Publication Number
5967-9953 December 1998
Applicable Products
HP ProCurve Switch 1600M (HP J4120A) HP ProCurve Switch 2424M (HP J4093A)
Disclaimer
The information contained in this document is subject to change without notice.
HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard.
Warranty
See the Customer Support/Warranty booklet included with the product.
A copy of the specific warranty terms applicable to your Hewlett-Packard products and replacement parts can be obtained from your HP Sales and Service Office or authorized dealer.
Safety
Before installing and operating these products, please read
the “Installation Precautions” in chapter 2, “Installing the Switch 1600M and 2424M”, and the safety statements in appendix C, “Safety and Regulatory Statements”.
Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.hp.com/go/procurve
Page 5
Contents
1 Introducing the HP ProCurve Switch 1600M and 2424M
Front of the Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Network Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Mode Select Button and Indicator LEDs . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Clear Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Back of the Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Slot for Switch Module (Switch 2424M) . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Switch Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Switch Operation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Address Table Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Simultaneous Network Communications . . . . . . . . . . . . . . . . . . . . . . . 1-9
Effect of VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
2 Installing the Switch 1600M and 2424M
Included Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Installation Precautions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
1. Prepare the Installation Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2. Install Switch Module (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
3. Verify the Switch Passes Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
LED Behavior: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
4. Mount the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Rack or Cabinet Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Horizontal Surface Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
iii
Page 6
5. Connect the Switch to a Power Source . . . . . . . . . . . . . . . . . . . . . . 2-13
6. Connect the Network Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Using the RJ-45 Connectors (10/100Base-TX ports) . . . . . . . . . . 2-14
Connecting Cables to the Switch Module . . . . . . . . . . . . . . . . . . . 2-14
7. (Optional) Connect a Console to the Switch . . . . . . . . . . . . . . . . . . 2-15
Terminal Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Direct Console Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Telnet Console Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Sample Network Topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
As a Desktop Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
As a Segment Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Connecting to a Backbone Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
Hot Swapping the Switch Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Adding or Replacing the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Changing the Module Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
Where to Go From Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-21
3 Troubleshooting
Basic Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Diagnosing with the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Proactive Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Hardware Diagnostic Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Testing the Switch by Resetting It . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Checking the Switch LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Checking Console Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Testing Twisted-Pair Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Testing Switch-to-Device Network Communications . . . . . . . . . . . . . 3-9
Testing End-to-End Network Communications . . . . . . . . . . . . . . . . . 3-10
Restoring the Factory Default Configuration . . . . . . . . . . . . . . . . . . 3-10
HP Customer Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Before Calling Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
iv
Page 7
A Specifications
Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Acoustic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
B Connectors and Cables
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Twisted Pair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Fiber-Optic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Twisted-Pair Cable/Connector Pin-Outs . . . . . . . . . . . . . . . . . . . . . . . B-3
Twisted-Pair Cable for Switch (MDI-X) to Computer (MDI)
10 Mbps or 100 Mbps Network Connection . . . . . . . . . . . . . . . . . . . . B-4
Twisted-Pair Cable for Switch (MDI-X) to Hub or Switch (MDI-X)
10 Mbps or 100 Mbps Network Connection . . . . . . . . . . . . . . . . . . . . B-5
Twisted-Pair Cable Pin Assignments
for 10 Mbps or 100 Mbps Operation . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
Twisted-Pair Straight-Through Cable . . . . . . . . . . . . . . . . . . . . . . B-6
Twisted-Pair Cross-Over Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
C Safety and EMC Regulatory Statements
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
EMC Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-8
Index
v
Page 8
Page 9
Introducing the HP ProCurve Switch 1600M and 2424M
The HP ProCurve Switch 1600M and 2424M are multiport switches that can be used to build high-performance switched workgroup networks. These switches are store-and-forward devices that offer low latency for high-speed networking.
HP ProCurve Switch 1600M
(HP J4120A)
1
Introducing the HP ProCurve
Switch 1600M and 2424M
HP ProCurve Switch 2424M
(HP J4093A)
Throughout this manual, these switches will be abbreviated as the Switch 1600M and Switch 2424M, or when common features are being described, as the Switch 1600M and 2424M.
The Switch 1600M and 2424M have 16 and 24 autosensing 10/100Base-T ports respectively. Both switches have a module slot for installing any of the supported switch modules. The modules provide expanded network connec­tivity, and media and network speed flexibility. For the Switch 2424M, the HP ProCurve Gigabit Stacking Module can be installed allowing up to seven switches to be stacked and interconnected with a high speed backbone.
With these switches you can build a switched network infrastructure by connecting them to hubs, other switches, or routers, or you can directly connect computers, printers, and servers to provide dedicated bandwidth to those devices.
This chapter describes your HP Switch 1600M and 2424M including:
Front and back of the switch
Features
Switch operation overview
1-1
Page 10
Introducing the HP ProCurve Switch 1600M and 2424M
Front of the Switches
Front of the Switches
Introducing the HP ProCurve
Switch 1600M and 2424M
Reset and Clear
Power
and Fault
LEDs
Console
buttons
port
Self Test
Console
port
Link and Mode LEDs
for Switch 2424M
10/100Base-TX ports
LED
Mode Select button
and indicator LEDs
Slot for Switch Module (Switch 1600M)
Status LEDs for switch module,
Mode Select button
and indicator LEDs
and fan
HP ProCurve Switch 1600M
10/100Base-TX RJ-45 ports
with Link and Mode LEDs at each port
HP ProCurve Switch 2424M
Self Test and
Module Status
LEDs
Reset and Clear
buttons
Network Ports
16 or 24 autosensing 10/100Base-TX ports
one universal switch module slot for installing any of the supported switch
modules (see “Features” on page 1-7). On the Switch 1600M, the slot is in the front; on the Switch 2424M, the slot is in the back.
1-2
10/100Base-TX
RJ-45 ports
Page 11
Introducing the HP ProCurve Switch 1600M and 2424M
Front of the Switches
LEDs
Table 1-1. Switch LEDs
Switch LEDs State Meaning
Power (green)
Fault (orange)
Self Test (green)
On The switch is receiving power.
Off The switch is NOT receiving power.
Off The normal state; indicates that there are no fault conditions on the switch.
Blinking
On On briefly after the switch is powered on or reset, at the beginning of switch self test.
Off The normal operational state; the switch is not undergoing self test.
On The switch self test and initialization are in progress after you have power cycled or
Blinking
A fault has occurred on the switch, the switch module (if installed), or a fan. The Status LED for the device with the fault will blink simultaneously.
If this LED is on for a prolonged time, the switch has encountered a fatal hardware
failure, or has failed its self test. See chapter 3, “Troubleshooting” for more information.
reset the switch. The switch is not operational until this LED goes off. The Self Test LED also comes on briefly when you “hot swap” a module into the switch; the module is self tested when it is hot swapped.
A component of the switch has failed its self test. The status LED for that component, for example a fan, and the switch Fault LED will blink simultaneously.
Introducing the HP ProCurve
Switch 1600M and 2424M
Mode Select (3 green LEDs)
Module Status (green)
Fan Status
(green)
Switch 1600M
only
The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
Act Indicates that the port Mode LEDs are displaying network activity information.
Fdx Indicates that the port Mode LEDs are lit for ports that are in Full Duplex Mode.
100 Indicates that the port Mode LEDs are lit for ports that are operating at 100 Mbps.
On A module is installed in the switch module slot and that the module is undergoing or
has passed self test.
Off A module is not installed in the switch module slot.
Blinking
On The cooling fans are operating normally.
Blinking
The module in the slot has failed self test or is not installed properly. The switch Fault LED, and the Self Test LED may be flashing simultaneously. If the Module Status LED is flashing by itself, a different module type has been hot swapped into the slot without
the switch being reset. See “Hot Swapping Switch Modules” on page 2-20.
One or more of the cooling fans have failed. The switch Fault LED will be flashing simultaneously.
1-3
Page 12
Introducing the HP ProCurve
Switch 1600M and 2424M
Introducing the HP ProCurve Switch 1600M and 2424M
Front of the Switches
Table 1-2. Switch Module LEDs
Port LEDs State Meaning
Link On Indicates the port is enabled and receiving a link beat signal (for the twisted-pair ports),
or a strong enough light level (for the fiber-optic ports on the switch modules) from the connected device.
Off One of these conditions exists:
• no active network cable is connected to the port
• the port is not receiving link beat or sufficient light
• the port has been disabled through the switch console, the web browser interface, or HP TopTools.
Mode Displays network activity information, or whether the port is configured for Full Duplex operation, or
100 Mbps operation depending on the mode selected. See “Mode Select Button and Indicator LEDs” below for more information.
Mode Select Button and Indicator LEDs
To optimize the amount of information that can be displayed for each of the switch ports without overwhelming you with LEDs, the Switch 1600M and 2424M use a Mode LED for each port. The operation of this LED is controlled by the Mode Select button, and the current setting is indicated by the Mode indicator LEDs near the button. Press the button to step from one mode to the next.
1-4
Mode Select button
and indicator LEDs
If the Activity (Act) indicator LED is lit, each Mode LED displays activity
Mode LED
(one for each port)
information for the associated port—it flickers as network traffic is received and transmitted through the port.
If the Full Duplex (Fdx) indicator LED is lit, the Mode LEDs light for those
ports that are operating in full duplex.
If the 100 Mbps (100) indicator LED is lit, the Mode LEDs light for those
ports that are operating at 100 Mbps.
Page 13
Introducing the HP ProCurve Switch 1600M and 2424M
Front of the Switches
Console Port
This port is used to connect a console to the switch by using the serial cable
supplied with the switch. This connection is described under “Connect a Console to the Switch” in chapter 2, “Installing the Switch 1600M and 2424M”. The console can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal.
Reset Button
This button is used to reset the switch while it is powered on. This action clears any temporary error conditions that may have occurred, executes the switch self test, and resets all network activity counters to zero. The counters are displayed in the switch console interface, the switch web browser interface, and through SNMP network management applications, such as HP TopTools for Hubs & Switches.
Clear Button
This button is used for these purposes:
Deleting Passwords - When pressed by itself for at least one second, the
button deletes any switch console access passwords that you may have configured. Use this feature if you have misplaced the password and need console access.
Introducing the HP ProCurve
Switch 1600M and 2424M
This button is provided for your convenience, but its presence means that if you are concerned with the security of the switch configuration and operation, you should make sure the switch is installed in a secure location, such as a locked wiring closet.
Restoring Factory Default Configuration - When pressed with the
Reset button in a specific pattern, clears any configuration changes you may have made through the switch console, the web browser interface, and SNMP management, and restores the factory default configuration to the switch. For the specific method to restore the factory default config­uration, see “Restoring the Factory Default Configuration” in chapter 3, “Troubleshooting” of this manual.
1-5
Page 14
Introducing the HP ProCurve
Switch 1600M and 2424M
Introducing the HP ProCurve Switch 1600M and 2424M
Back of the Switches
Back of the Switches
.
HP ProCurve Switch 1600M
AC power connector
cooling vent - make sure this is not
obstructed for proper switch operation
HP ProCurve Switch 2424M
Slot for Switch Module (Switch 2424M)
Power Connector
The Switch 1600M and Switch 2424M do not have a power switch; they are powered on when connected to an active AC power source. The switches automatically adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz. There are no voltage range settings required.
Slot for Switch Module (Switch 2424M)
The slot for installing any of the supported switch modules in the Switch 2424M is in the back of the switch. For a description of the modules, see
“Features” on page 1-7.
1-6
Page 15
Introducing the HP ProCurve Switch 1600M and 2424M
Switch Features
Switch Features
The features of the Switch 1600M and 2424M include:
16 or 24 autosensing 10/100Base-TX RJ-45 ports
a slot for installing any of the available switch modules—as of this
printing, these include:
8-port 10/100Base-TX Module (HP J4111A)
4-port 100Base-FX Module (HP J4112A)
1-port Gigabit-SX Module (HP J4113A)
1-port Gigabit-LX Module (HP J4114A)
4-port 10Base-FL Module (HP J4118A)
Gigabit Stacking Module (HP J4130A — for Switch 2424M only, available Summer 1999)
the modules are “hot swappable”
plug-and-play networking—all ports are enabled—just connect the
network cables to active network devices and your switched network is operational
automatic learning of the network addresses in the switch’s 8000-address
forwarding table, with configurable address aging value
automatically negotiated full-duplex operation of the 10 Mbps, 100 Mbps,
ports when connected to other auto-negotiating or full-duplex devices — Gigabit ports always operate at full duplex
easy management of the switches through several available interfaces:
web browser interface—an easy to use built-in graphical interface that can be accessed from common web browsers.
console interface—a full featured, easy to use, VT-100 terminal interface that is especially good for out-of-band switch management, or for telnet access to the switch.
HP TopTools for Hubs & Switches—an SNMP-based, full-featured graphical network management tool that you can use to manage your entire network. This product is included with your new switch.
support for the Spanning Tree Protocol to eliminate network loops
support for up to 30 IEEE 802.1Q-compliant VLANs so you can divide the
attached end nodes into logical groupings that fit your business needs
support for many advanced features to enhance network performance—
described in the Management and Configuration Guide that came with your switch.
Introducing the HP ProCurve
Switch 1600M and 2424M
1-7
Page 16
Introducing the HP ProCurve
Switch 1600M and 2424M
Introducing the HP ProCurve Switch 1600M and 2424M
Switch Operation Overview
Switch Operation Overview
Address Table Operation
Address Learning. As devices are connected to the switch ports, either directly or through hubs or other switches, the MAC addresses of those devices are learned automatically and stored in the 8000-entry address table featured by the Switch 1600M and 2424M. The switches also identify the number of the port on which each address is learned so they know the network location of each device.
Forwarding, Filtering, Flooding. When the switch receives a packet, it determines the destination address and looks for the address in the address table. Based on the port location of that address, the switch then determines whether to forward, filter-out, or flood the packet.
forward - if the destination address is on a different port than the one on
which the packet was received, the packet is forwarded to the destination port and on to the destination device.
filter out - if the destination address is on the same port as the one on
which the packet was received, the packet is filtered out. The switch thereby isolates local traffic so the rest of the network connected to the switch does not lose bandwidth dealing with unnecessary traffic.
flood - whenever a new destination address is found in a packet received
on one switch port, the destination address will not yet be in the switch’s address table and the switch cannot know whether to forward or filter out the packet. In this case, it sends the packet to all the other switch ports. This is referred to as “flooding”. When the destination device receives the packet, it replies, and the switch learns the new address from the reply packet. Then, all future packets destined for that address are forwarded or filtered out appropriately.
Network Moves and Changes. When devices are moved in the network, and become connected to a different switch port, the Switch 1600M and 2424M automatically recognize the change and update the address table with the new port location of the device. Communication with the device is automatically maintained, without any address table manipulation being required.
1-8
Page 17
Introducing the HP ProCurve Switch 1600M and 2424M
Switch Operation Overview
Simultaneous Network Communications
As part of the traffic isolation benefits provided by the Switch 1600M and 2424M address table operation, the switches enhance network performance because they can conduct multiple, simultaneous network connections. Instead of sharing the network bandwidth, as in connections to a hub, each connection has its own 10 Mbps, 100 Mbps, or 1000 Mbps bandwidth to use.
Effect of VLANs
If you configure multiple virtual LANs (VLANs) on the switch, each VLAN
behaves as a “logical switch” containing the switch ports that you assign to it. Each logical switch behaves as an isolated broadcast domain, just as if it were an isolated physical switch. The forward, filter, and flood behavior described for the physical switch above, operates the same for each of the logical switches defined by the VLANs: packets are forwarded or flooded only to the ports that are within a given VLAN. Just as for separate isolated physical switches, there is no communication between ports that are in separate VLANs unless the VLANs are connected by an external router.
For more information on configuring VLANs and their behavior, see the Management and Configuration Guide that came with your switch.
Introducing the HP ProCurve
Switch 1600M and 2424M
1-9
Page 18
Page 19
c2.fm Page 1 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
The HP Switch 1600M and 2424M are easy to install units. They each come with an accessory kit that includes the brackets for mounting the switch in a standard 19-inch telco rack or an equipment cabinet, or on a wall, and with rubber feet that can be attached so the switch can be securely located on a horizontal surface. The brackets are designed to allow mounting the switch in a variety of orientations.
This chapter shows you how to install your Switch 1600M and 2424M.
2
Installing the Switch 1600M
and 2424M
Included Parts
The Switch 1600M and 2424M have the following components shipped with them:
HP ProCurve Switch 1600M and 2424M Installation Guide (5967-6966),
this manual
HP ProCurve Switch Management and Configuration Guide
(5967-2142 for the 1600M, and 5967-6967 for the 2424M)
HP TopTools for Hubs & Switches - CD ROM and booklet
Customer Support/Warranty booklet
Accessory kit (5064-4280)
two mounting brackets
four 10 mm M4 screws to attach the mounting brackets to the switch
four 5/8-inch number 12-24 screws to attach the switch to a rack
four rubber feet
Console cable
Power cord, one of the following:
Australia/New Zealand China Continental Europe Denmark Japan Switzerland United Kingdom/Hong Kong/Singapore United States/Canada/Mexico
8120-6803 8120-8377 8120-6802 8120-6806 8120-6804 8120-6807 8120-8709 8120-6805
2-1
Page 20
c2.fm Page 2 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
Installation Procedures
Summary
Follow these easy steps to install your switch. The rest of this chapter provides details on these steps.
1. Prepare the installation site (page 2-4). Make sure that the physical
2. Install switch module (optional—page 2-6). The switches have a slot
and 2424M
environment into which you will be installing the switch is properly prepared including having the correct network cabling ready to connect to the switch, and having a good location for the switch. Please see page
2-3 for some installation precautions.
for installing any of the supported HP switch modules. Depending on where you will install the switch, it may be easier to install the module
first, but the modules are “hot swappable”—they can also be installed and removed after the switch is installed and powered on.
3. Verify that the switch passes self test (page 2-8). This is a simple
Installing the Switch 1600M
process of plugging the switch into a power source and observing that the LEDs on the switch’s front panel and on any optional modules indicate correct switch operation.
4. Mount the switch (page 2-10). The Switch 1600M and 2424M can be mounted in a 19-inch telco rack, in an equipment cabinet, on a wall, or on a horizontal surface.
5. Connect power to the switch (page 2-13). Once the switch is mounted, plug it in to the nearby main power source.
6. Connect the network devices (page 2-14). Using the appropriate network cables, connect other switches, hubs, routers, computers, servers, printers, and other network devices to the switch ports.
7. Connect a console to the switch (optional—page 2-15). You may wish to modify the switch’s configuration, for example, to configure an IP address so it can be managed using a web browser, from an SNMP network management station, or through a telnet session to the switch console. Configuration changes can be made easily by using the included console cable to connect a PC to the switch’s console port.
At this point, the switch is fully installed and your network should be up and running. See the rest of this chapter if you need more detailed information on any of these installation steps.
2-2
Page 21
c2.fm Page 3 Tuesday, January 12, 1999 1:26 PM
Installation Precautions:
Follow these precautions when installing your HP Switch 1600M and 2424M.
Warning The rack or cabinet should be adequately secured to prevent it from
Installing the Switch 1600M and 2424M
Installation Procedures
becoming unstable and/or falling over.
Devices installed in a rack or cabinet should be mounted as low as possible, with the heaviest device at the bottom and progressively lighter devices installed above.
Installing the Switch 1600M
Cautions Make sure that the power source circuits are properly grounded, then use
the power cord supplied with the switch to connect it to the power source.
If your installation requires a different power cord than the one supplied with the switch, be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the switch.
Ensure that the switch does not overload the power circuits, wiring, and
over-current protection. To determine the possibility of overloading the supply circuits, add together the ampere ratings of all devices installed on the same circuit as the switch and compare the total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the AC power connectors.
Do not install the switch in an environment where the operating ambient
temperature might exceed 55°C (131°F).
Make sure the air flow around the sides and back of the switch is not
restricted.
Make sure that if no module is installed in the module slot, the cover plate
is installed to cover the slot. A cover plate is required for safe operation, and to ensure proper switch cooling.
and 2424M
2-3
Page 22
c2.fm Page 4 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
1. Prepare the Installation Site
Cabling Infrastructure - Ensure that the cabling infrastructure meets
Table 2-1. Summary of Cable Types to Use with the Switch
Port Type Cable Type Length Limits
the necessary network specifications. See the following table for cable types and lengths, and see appendix B, “Cables and Connectors” for more
information:
and 2424M
Installing the Switch 1600M
10/100Base-TX • 10 Mbps operation:
Category 3, 4, or 5, 100-ohm unshielded twisted-pair (UTP)
• 100 Mbps operation:
Category 5, 100-ohm UTP or shielded twisted-pair (STP) cable.
10Base-FL (on the 10FL Module)
100Base-FX (on the 100FX Module)
Gigabit-SX (on the Gigabit-SX Module and the Gigabit Stacking Module with SX transceivers)
62.5/125 µm or 50/125 µm core/cladding
diameter, graded-index, multimode fiber­optic cables that are fitted with ST connectors
62.5/125 µm or 50/125 µm core/cladding
diameter, graded-index, multimode fiber­optic cables that are fitted with SC connectors
62.5/125 µm or 50/125 µm core/cladding
diameter, graded-index, multimode fiber­optic cables that are fitted with SC connectors
100 meters
Note: Since the 10Base-T operation is through 10/100Base-TX ports, if you ever want to upgrade the ports to 100Base-T, it would be best to cable the ports initially with category 5 cable.
For connecting these ports to end nodes or other
MDI ports, use “straight-through” cable; for connecting to MDI-X ports on hubs or other switches, use “crossover” cable.
1 kilometer
• 412 meters for half-duplex connections
• 2 kilometers for full-duplex connections
•62.5 µm cable:
– 160 MHz*km = 220 meters – 200 MHz*km = 275 meters
•50 µm cable:
– 400 MHz*km = 500 meters – 500 MHz*km = 550 meters
Gigabit-LX (on the Gigabit-LX Module and the Gigabit Stacking Module with LX transceivers)
single-mode cables fitted with SC connectors
62.5/125 µm or 50/125 µm core/cladding
diameter, graded-index, multimode fiber­optic cables may also be used, but a mode conditioning patch cord may be needed — see the the module for more information
Installation Guide
2-4
• single-mode cable - 5 kilometers
• multimode cable - 550 meters
that came with
Page 23
c2.fm Page 5 Tuesday, January 12, 1999 1:26 PM
Installation Location - Before installing the switch, plan its location and
Installing the Switch 1600M and 2424M
Installation Procedures
orientation relative to other devices and equipment:
In the front of the switch, leave at least 7.6 cm (3 inches) of space for
the twisted-pair and fiber-optic cabling.
In the back of the switch, leave at least 3.8 cm (1 1/2 inches) of space
for the power cord and any network cabling for any installed modules. For the Switch 2424M, if you are installing a Gigabit Stacking Module in the back, allow an additional 10 cm (4 inches) for the module and the fiber-optic or twisted-pair cabling.
On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling.
Installing the Switch 1600M
and 2424M
2-5
Page 24
c2.fm Page 6 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
2. Install Switch Module (optional)
Install a switch module into the slot as shown in the illustration on the next page. For installation details, see the instructions in the Installation Guide that comes with the module.
The slot cover can be removed with either a flat-bladed or Torx T-10 screw­driver. Keep the slot cover for future use.
Notes Any of the supported switch modules can be installed in the slot in the
The modules can be “hot swapped”, installed when the switch is powered
Switch 1600M and 2424M, except the Gigabit Stacking Module, which can be installed only in the Switch 2424M.
on and normally will be immediately operational. But, if the new module is replacing a module of a different type than what was previously installed in the slot, the switch must be rebooted after the new module is installed. See “Hot Swapping the Switch Module” on page 2-20.
and 2424M
Installing the Switch 1600M
The transceivers that provide the ports in the Gigabit Stacking Module for the Switch 2424M are NOT hot swappable. See the HP ProCurve Switch 2424M Gigabit Stacking Module Installation Guide or the HP ProCurve Gigabit Transceivers Installation Guide for more informa­tion.
Make sure the module is fully installed and that you screw in the
retaining screws to secure the module in place.
If you do not install a module in the slot, make sure that the slot cover
plate is still attached over the slot for safe operation and proper switch cooling.
2-6
Page 25
c2.fm Page 7 Tuesday, January 12, 1999 1:26 PM
Installing a Switch Module in the Switch 1600M
Insert module into the guides and slide it in until it stops. Then press in firmly until
the module “snaps” into place and is flush with the face of the switch.
make sure you tighten the retaining screws on the module
Installing the Switch 1600M and 2424M
Installation Procedures
Then
.
Installing the Switch 1600M
and 2424M
Installing a Switch Module in the Switch 2424M
2-7
Page 26
c2.fm Page 8 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
3. Verify the Switch Passes Self Test
Before mounting the switch in its network location, you should first verify that it is working properly by plugging it into a power source and verifying that it passes its self test.
1. Connect the power cord supplied with the switch to the power connector on the back of the switch, and then into a properly grounded electrical outlet.
Connect power c ord to
the power connector
and 2424M
Installing the Switch 1600M
Note The Switch 1600M and Switch 2424M do not have a power switch. They are
powered on when the power cord is connected to the switch and to a power source.
If your installation requires a different power cord than the one supplied with the switch, be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the switch.
2. Check the LEDs on the switch and on the switch module (if installed in the switch). The LED behavior is described on the next page.
Note The illustration on the next page shows a Switch 1600M. The LEDs on the
Switch 2424M are located differently than what is shown, but the LED behavior is the same as described on the page.
2-8
Page 27
c2.fm Page 9 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
switch port LEDs
Power and Fault LEDs
LED Behavior:
Self Test LED
Installing the Switch 1600M
When the switch is powered on, it performs its diagnostic self test. The self test takes approximately 45 seconds to complete.
and 2424M
During the self test:
Initially, all the switch and port LEDs are on.
After approximately 3 seconds most of the LEDs go off and then may
come on again during phases of the self test. For the duration of the self test, the Self Test LED stays on.
When the self test completes successfully:
•The Power LED remains on.
For the Switch 1600M, the Fan Status LED also stays on.
For a switch in which a module is installed, the Module Status LED
also stays on.
•The Fault and Self Test LEDs go off.
The port LEDs on the front of the switch and on the switch module
go into their normal operational mode: – If the ports are connected to active network devices, the Link
LEDs stay on and the Mode LEDs behave according to the mode selected. In the default mode (Activity), the Mode LEDs should flicker showing network activity on the port.
If the ports are not connected to active network devices, the Link
and Mode LEDs will stay off.
If the LED display is different than what is described above, especially if the Fault and Self Test LEDs stay on for more than 60 seconds or they start blinking, the self test has not completed correctly. Refer to chapter 3, “Troubleshooting” for diagnostic help.
2-9
Page 28
c2.fm Page 10 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
4. Mount the Switch
After you have verified that the switch passes self test, you are ready to mount the switch in a stable location. The Switch 1600M and 2424M can be mounted in these ways:
in a rack or cabinet
on a horizontal surface
on a wall
Rack or Cabinet Mounting
The Switch 1600M and 2424M are designed to be mounted in any EIA-standard 19-inch telco rack or in an equipment cabinet such as a server cabinet.
and 2424M
Installing the Switch 1600M
Warning For safe operation, please read the mounting precautions on
page 2-3, before mounting a switch.
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting brackets to the switch with the included 10-mm M4 screws.
10 mm
M4 screws
2-10
Page 29
c2.fm Page 11 Tuesday, January 12, 1999 1:26 PM
2. Partially install a screw (5/8-inch number 12-24) into the top hole of a pair
.
partially install a screw
into the top hole of a
close (0.5-inch) pair on
both sides of the rack
Installing the Switch 1600M and 2424M
Installation Procedures
of holes that are 0.5 inches apart in each rack/cabinet upright as shown in the illustration below. Ensure that the screws are at the same level in each upright.
Installing the Switch 1600M
and 2424M
3. Place the switch in the rack and lower it so the notches in the bottom of the bracket slide onto the screws, then tighten these screws.
.
lower switch with mounting
brackets onto the partially
installed screw
2-11
Page 30
c2.fm Page 12 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
4. Install the other number 12-24 screw into the upper hole in each bracket.
install additional
screw
Tighten these screws.
and 2424M
Installing the Switch 1600M
Horizontal Surface Mounting
Attach the bumper feet included in the accessory kit to the bottom of the switch, and place the switch on a table or other horizontal surface. Use a sturdy surface in an uncluttered area. You may want to secure the networking cables and switch power cord to the table legs or other part of the surface structure to help prevent people from tripping over the cords.
Note Make sure the air flow is not restricted around the sides and back of the switch.
2-12
Page 31
c2.fm Page 13 Tuesday, January 12, 1999 1:26 PM
Wall Mounting
You can mount the switch on a wall as shown in the illustration below.
Caution The switch should be mounted only to a wall or wood surface that is at least
1/2-inch plywood or its equivalent.
1. Use a #1 Phillips (cross-head) screwdriver and attach the mounting
2. Attach the switch to the wall or wood surface with two 5/8-inch number
Installing the Switch 1600M and 2424M
Installation Procedures
brackets to the switch with the included 10-mm M4 screws.
12 wood screws (not included).
Installing the Switch 1600M
and 2424M
10 mm M4
screws
5/8-inch wood
screws
5. Connect the Switch to a Power Source
1. Plug the included power cord into the switch’s power connector and into
a nearby AC power source.
2. Re-check the LEDs during self test. See “LED Behavior” on page 2-9.
2-13
Page 32
X
2
c2.fm Page 14 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
6. Connect the Network Cables
Connect the network cables, described under “Cabling Infrastructure” (page 2-4), from the network devices or your patch panels to the fixed RJ-45 ports on the switch or the ports on any module you have installed in the switch.
Using the RJ-45 Connectors (10/100Base-TX ports)
To c on ne ct :
Push the RJ-45 plug into the RJ-45 jack until the tab on the plug clicks into place. When power is on for the switch and for the connected device, the Link LED for the port should light to confirm a powered-on device (for example, an end node) is at the other end of the cable.
1X
Link
9X
Link
2X 3X 4
Mode
10X 11X 1
Mode
RJ-45 connector
and 2424M
Installing the Switch 1600M
If the Link LED does not go on when the network cable is connected to the port, see “Diagnosing With the LEDs” in chapter 3, “Troubleshooting”.
Unshielded twisted-pair cable:
• Category 3, 4, or 5 for 10 Mbps ports
• Category 5 only for 100 Mbps ports
Maximum distance: 100 meters
To disconnect:
Press the small tab on the plug and pull the plug out of the jack
.
Connecting Cables to the Switch Module
If you have a switch module installed in the switch, the type of network connections you will need to use depends on the type of module you have installed. See the documentation accompanying the modules for cabling configurations and procedures for those modules.
The module documentation will also cover troubleshooting procedures for connections to the module, but, in general for all the switch ports, when a network cable from an active network device is connected to the port, the Link LED for that port should go on. If the Link LED does not go on when the network cable is connected to the port, see “Diagnosing With the LEDs” in chapter 3, “Troubleshooting”.
2-14
Page 33
c2.fm Page 15 Tuesday, January 12, 1999 1:26 PM
7. (Optional) Connect a Console to the Switch
The Switch 1600M and 2424M have a full-featured, easy to use console interface for performing the following tasks:
Monitor switch and port status and observe network activity counters
Modify the switch’s configuration
Read the event log and access diagnostic tools to help in troubleshooting
Download new software to the switch
Add passwords to control console, web browser interface, and
Installing the Switch 1600M and 2424M
Installation Procedures
network management access to the switch
The console can be accessed through these methods:
Out-of-band: The Switch 1600M and 2424M come with a serial cable for
connecting a PC or VT-100 terminal to be used as a console directly to the switch. If the PC or terminal has a 25-pin serial connector, you can use a readily available 9-pin to 25-pin serial cable, or attach a 9-to-25 pin adapter to the end of the supplied cable.
In-Band: Access the console using Telnet from a PC or UNIX station on
the network, and a VT-100 terminal emulator. This method requires that you first configure the switch with an IP address and subnet mask by using either out-of-band console access or through DHCP/Bootp.
The Switch 1600M and 2424M can simultaneously support one out-of-band console session through the Console Port and one in-band telnet console session.
Terminal Configuration
To connect a console to the switch, configure the PC terminal emulator as a DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either one to operate with these settings:
any baud rate from 2400 to 115200 (the switch senses the speed)
8 data bits, 1 stop bit, no parity, and flow control set to XON/XOFF
(Switch 1600M) or None (Switch 2424M).
For the Windows Terminal program, also disable (uncheck) the “Use
Function, Arrow, and C
For the Hilgrave HyperTerminal program, select the “Windows keys”
option for the “Function, arrow, and ctrl keys act as” parameter.
trl Keys for Windows” option.
Installing the Switch 1600M
and 2424M
If you want to operate the console using a different configuration, make sure you change the settings on both the terminal and on the switch. Change the switch settings first, then change the terminal settings, and reestablish the console session.
2-15
Page 34
c2.fm Page 16 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Installation Procedures
Direct Console Access
To connect a console to the switch, follow these steps:
1. Connect the PC or
2. Turn on the terminal or
and 2424M
terminal to the switch’s Console Port using the console cable included with the switch. (If your PC or terminal has a 25-pin serial connector, first attach a 9-pin to 25-pin adapter at one end of the console cable.)
PC’s power and, if using a PC, start the PC terminal program.
console port
console cable s upplied
with the switch
PC running a terminal
emulator program, or
a VT-100 terminal
Switch1600
HPJ4120A
Power
ConsoleFault
A
Reset
3. Press [Enter] two or three times and you will see the copyright page and the
Installing the Switch 1600M
message “Press any key to continue”. Press a key, and you will then see the switch console Main Menu.
Telnet Console Access
To access the switch through a telnet session, follow these steps:
1. Make sure the switch is configured with an IP address and that the switch is reachable from the telnet workstation (for example by using a Ping command to the switch’s IP address).
2. Start the telnet program and connect to the switch’s IP address.
3. You will see the copyright page and the message “Press any key to continue”. Press a key, and you will then see the switch console Main Menu.
If you want to continue with console management of the switch at this time, refer to the Management and Configuration Guide that came with your switch.
2-16
Page 35
c2.fm Page 17 Tuesday, January 12, 1999 1:26 PM
Sample Network Topologies
This section shows you a few sample network topologies in which the Switch 1600M and 2424M are implemented. For more topology information, see the document Designing HP AdvanceStack Workgroup Networks, which can be found on the HP network products World Wide Web site, http://www.hp.com/ go/procurve. You may also be able to obtain a printed copy of this document from your HP-authorized LAN dealer.
Installing the Switch 1600M and 2424M
Sample Network Topologies
As a Desktop Switch
twisted-pair
“straight-through”
cables
Switch 2424M is designed to be used primarily as a desktop switch to which end nodes, printers and other peripherals, and servers are directly connected, as shown in the above illustration. Notice that the end node devices are
connected to the switch by “straight-through” twisted-pair cables.
Installing the Switch 1600M
and 2424M
Server
Switch 2424M
PCs and
peripherals
2-17
Page 36
c2.fm Page 18 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Sample Network Topologies
As a Segment Switch
and 2424M
Installing the Switch 1600M
Server with
“Fast” Ethernet
100 Base-FX
fiber-optic cable
to backbone
“Fast”
Ethernet
Hubs
twisted-pair
“straight-through ”
cables to end
nodes
category 5 twisted-pair “straight-through”
NIC
cable for 100 Mbps connection to server
Switch 1600M
twisted-pair “cross-over”
cables to hubs
printers,
and local
servers
The Switch 1600M can also be used as a desktop switch, but it works well as a segment switch. That is, with its high performance, it can be used for
interconnecting network segments—simply connect the network hubs that form those segments to the switch, or connect other switches.
PCs,
2-18
In the illustration above, two “Fast” Ethernet hubs with PCs, printers, and local servers attached, are both connected to a Switch 1600M. The devices attached to the two hubs can now communicate with each other through the switch. They can also all communicate with the server that is connected to the switch through its 100Base-TX port.
The connections between the switch and the MDI-X ports on the hubs is through category 5 “cross-over” twisted-pair cable. Category 3 or 4 cable can also be used if the connection is 10 Mbps only. If the hubs have MDI ports, you can connect them to the switch through “straight-through” cable. The connec­tion to the server is through category 5 “straight-through” twisted-pair cable.
The switch, in turn, is connected to a network backbone through fiber-optic cabling connected to a 100Base-FX module installed in the switch. Now, all the devices on these network segments can access other network resources that are connected elsewhere on the network backbone.
Page 37
c2.fm Page 19 Tuesday, January 12, 1999 1:26 PM
Connecting to a Backbone Switch
to Gigabit-Ethernet
backbone
Installing the Switch 1600M and 2424M
Sample Network Topologies
Switch 2424M
Installing the Switch 1600M
and 2424M
Switch 8000M
Switch 1600M
The simpler desktop and segment networks shown in the previous two examples can easily be combined and expanded. For example, you could use an HP ProCurve Switch 8000M to interconnect each of your smaller switched workgroups to form a larger switched network. All the devices in this network can communicate with each other. With a Gigabit-SX Module, for example, in the Switch 8000M, the entire switched topology could be connected to a campus backbone, as shown in the illustration above.
Note In the illustration above, the 100 Mbps fiber-optic connection between the
Switch 2424M and the Switch 8000M is by way of a 100Base-FX Module installed in the back of the Switch 2424M.
2-19
Page 38
c2.fm Page 20 Tuesday, January 12, 1999 1:26 PM
Installing the Switch 1600M and 2424M
Hot Swapping the Switch Module
Hot Swapping the Switch Module
Any of the HP ProCurve Switch Modules can be “hot swapped”, that is installed
or replaced while the switch is powered on. The procedures differ slightly, though, between adding a new module to the empty slot or replacing the module with the same type, and exchanging the module with a different type.
Caution The gigabit transceivers that provide the ports for the Gigabit Stacking
Module for the Switch 2424M are NOT hot swappable. The transceivers must be installed, removed, or replaced when the module is not receiving power from the switch, either by installing the transceivers before installing the module, removing the module from the switch before installing or removing the transceivers, or powering off the switch before installing or removing the transceivers. Please see the installation guide that came with your Gigabit Stacking Module or Gigabit Transceivers for more information.
and 2424M
Adding or Replacing the Module
Installing the Switch 1600M
If a module has to be replaced with one of the same type, or you are expanding the switch capability by adding a module for the first time, the replaced or new module is immediately operational; there is no interruption to the switch operation.
Changing the Module Type
If you exchange the module with one of a different type, for example a 100Base-FX module is installed in place of a 10/100Base-T module that was in the slot, the switch must be rebooted after the new module is installed so the switch processor can properly initialize and configure the new module type.
You can reboot the switch by any of these methods:
select the Reset or Reboot option from the console, web browser inter-
face, or HP TopTools for Hubs & Switches
press the Reset button on the switch
unplug and plug in the power cord (power cycle)
Until the switch is rebooted, the new module will not operate, the Module Status LED will continue to blink, and all the LEDs on the module will stay on continuously.
2-20
Page 39
c2.fm Page 21 Tuesday, January 12, 1999 1:26 PM
Where to Go From Here
Your switch is now correctly installed and is able to send and receive data between end nodes, servers, and printers.
The Switch 1600M and 2424M are plug-and-communicate network devices requiring no configuration. If you wish to manage these switches from an SNMP-based network management station, you will need to configure the IP address on the switches; see the Management and Configuration Guide that came with your switch for information on how to use the switch console to configure the IP address.
Installing the Switch 1600M and 2424M
Where to Go From Here
Installing the Switch 1600M
Note The Switch 1600M and 2424M can also be managed through a graphical
interface that you can access from any PC or workstation on the network by
running your web browser and typing in the switch’s IP address as the URL. No additional software installation is required to make this interface available; it is included in the switch’s onboard software.
and 2424M
2-21
Page 40
c2.fm Page 22 Tuesday, January 12, 1999 1:26 PM
Page 41
Troubleshooting
This chapter describes how to troubleshoot your Switch 1600M and 2424M. Note that this document describes troubleshooting mostly from a hardware perspective. You can perform more in-depth troubleshooting using the soft­ware tools available with the switch, including the full-featured console interface, the built-in web browser interface, and HP TopTools for Hubs & Switches, the SNMP-based network management tool. See the Trouble­shooting chapter of the Management and Configuration Guide included with your switch for more information.
This chapter describes the following:
basic troubleshooting tips (page 3-2)
diagnosing with the LEDs (page 3-4)
Proactive Networking tools (page 3-7)
hardware diagnostic tests (page 3-8)
restoring the factory default configuration (page 3-10)
HP Customer Support Services (page 3-11)
3
Troubleshooting
3-1
Page 42
Troubleshooting
Basic Troubleshooting Tips
Basic Troubleshooting Tips
Most problems are caused by the following situations. Check for these items first when starting your troubleshooting:
Incorrect switch-to-switch or switch-to-hub connections. If you
have connected your switch to another switch or a hub by using twisted­pair cable from an RJ-45 MDI-X connector on your switch to an MDI-X connector on the other switch or hub, you must use a crossover cable. If you have used a straight-through cable, the connection will not work. The LED for the port you are using will not come on when you connect the cable.
Most switch and hub ports are wired as MDI-X ports, so for these switch­to-switch or switch-to-hub connections use a crossover cable. LAN adapters in end nodes are normally wired as MDI ports, as are some ports on hubs and switches. For connections from the switch to these MDI ports, use a straight-through cable. See appendix B, “Cables and
Connectors” for pinouts and correct cable wiring for crossover and straight-through twisted-pair cables.
Faulty or loose cables. Look for loose or obviously faulty connections.
If they appear to be OK, make sure the connections are snug. If that does not correct the problem, try a different cable.
Non-standard cables. Non-standard and miswired cables may cause
numerous network collisions and other network problems, and can seri­ously impair network performance. Use a new correctly-wired cable or compare your cable to the cable in appendix B, “Cables and Connectors” for pinouts and correct cable wiring. A category 5 cable tester is a
Troubleshooting
recommended tool for every 100Base-T network installation.
Improper Network Topologies. It is important to make sure you have
a valid network topology. Common topology faults include excessive cable length and excessive repeater delays between end nodes. If you have network problems after recent changes to the network, change back to the previous topology. If you no longer experience the problems, the new topology is probably at fault. Refer to the Network Design Guide for topology configuration guidelines. This guide can be found online at the HP World Wide Web site for networking products, http://www.hp.com/go/ procurve under the
[Tech Library] button.
3-2
Page 43
Troubleshooting
Basic Troubleshooting Tips
In addition, you should make sure that your network topology contains no data path loops. Between any two end nodes, there should be only one active cabling path at any time. Data path loops will cause broadcast storms that will severely impact your network performance.
If you wish to build redundant paths between important nodes in your network to provide some fault tolerance, you should enable Spanning Tree Protocol support on the switch. This ensures that only one of the redundant paths is active at any time, thus avoiding data path loops. Spanning Tree can be enabled through the switch console, the web browser interface, or HP TopTools for Hubs & Switches.
The Switch 1600M also supports Switch Meshing which allows multiple data paths though a switched network to be active simultaneously for enhanced network bandwidth. See the Management and Configuration Guide that came with your switch for more information on Spanning Tree and on Switch Meshing.
Check the port configuration. A port may not be operating as you
expect because it has been put into a “blocking” state by Spanning Tree
or Switch Meshing. Or, the port just may have been configured as disabled through software.
Use the switch console to determine the port’s configuration and verify that there is not an improper or undesired configuration of any of the switch features that may be affecting the port. See the Management and Configuration Guide that came with your switch for more information.
Troubleshooting
3-3
Page 44
Troubleshooting
Diagnosing with the LEDs
Diagnosing with the LEDs
Tables 3-1 shows LED patterns on the switch and the switch modules that indicate problem conditions.
1. Check in the table for the LED pattern that you see on your switch.
2. Refer to the corresponding diagnostic tip on the next few pages.
Table 3-1. LED Error Indicators
LED Pattern Indicating Problems
Module
Power Fault Self Test
Off with
power
cord
plugged
in
On Prolonged OnProlonged
On Blinking
On Blinking
On Off Off Blinking
On Blinking
**** *
On
Blinking
Blinking
Blinking
Off * Blinking
Status
** *
** *
Fan Status
1600M only)
Link
(Switch
* All Link and Mode
**
(per port)
LEDs On
*
Diagnostic
Tips
➋ ➌
➍ ➎
Troubleshooting
On Off Off On * Off with cable
connected
On Off Off On * On, but the port is
not
communicating
➐ ➑
* This LED is not important for the diagnosis.
The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
3-4
Page 45
Diagnostic Tips:
Tip Problem Solution
Troubleshooting
Diagnosing with the LEDs
The switch is not plugged into an active AC power source, or the
switch’s power supply may have failed.
A switch hardware failure has occurred. All the LEDs will st ay on indefinitely.
The switch has experienced a software failure during self test.
The module installed in the slot is not installed properly, has experienced a self test fault, or has become partly removed during switch operation.
1. Verify that the power cord is plugged into an active power source and to the switch. Make sure these connections are snug.
2. Try power cycling the switch by unplugging and plugging the power cord back in.
3. If the Power LED is still not on, verify that the AC power source works by plugging another device into the outlet. Or try plugging the switch into a different outlet or try a different power cord.
If the power source and power cord are OK and this condition persists, the switch power supply may have failed. Call your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty card for more information.
Try power cycling the switch. If the fault indication reoccurs, the switch may have failed. Call your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty card for more information.
1. Try resetting the switch by pressing the Reset button on the front of the switch, or by power cycling the switch.
2. If the fault indication reoccurs, attach a console to the switch (as indicated in chapter
2) and configure it to operate at 9600 baud. Then, reset the switch. Messages should appear on the console screen and in the console log identifying the error condition. You can view the console log at that point by selecting it from the console Main Menu.
If necessary to resolve the problem, contact your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/ Warranty card for more information.
The module is tested whenever the switch is powered on, or reset (through the Reset button on the switch, or the Reboot or Reset options in the console or web browser interface), and when it is hot swapped (installed when the switch is powered on).
Under this error condition, the following events also occur:
• All the LEDs on the module stay on until the error is resolved.
• The switch software, including console and web browser access will not be opera­tional for approximately one minute from the time the module gets into this condition.
Try rebooting the switch again. If that does not resolve the problem, try reinstalling the module. You can do this without having to power down the switch. When the module is reinstalled, it will be retested automatically. Make sure to screw in the retaining screws so that the module cannot be inadvertently pulled out by pulling on the network cables.
If the fault indication reoccurs, the module may have failed. Remove the module from the switch and replace it with another module, or cover the slot with the cover plate. Call your HP-authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty card for more information.
Troubleshooting
3-5
Page 46
Troubleshooting
Diagnosing with the LEDs
Tip Problem Solution
A module was installed in the slot that is a different type than the previously installed module, and the switch has not yet been reset.
One or more of the switch cooling fans may have failed. (Switch 1600M only)
The network connection is not working properly.
When you “hot swap” modules in the module slot, if you install a different module type than the one that was previously installed in the slot, you must reset the switch. This allows the switch processor to properly initialize and configure the new module type. The blinking LED informs you that this change of module types has occurred. The module will not work properly until the switch is reset as indicated by all the module’s LEDs staying on until the switch is reset.
You can reset the switch by any of these methods:
• pressing the Reset button on the switch
• power cycling the switch
• selecting the reset or reboot option from the console, web browser interface, or HP Top Too ls .
Try disconnecting power from the switch and wait a few moments. Then reconnect the power to the switch and check the LEDs again. If the error indication reoccurs, one or more of the fans has failed. The switch has two fans and may continue to operate OK under this condition if the ambient temperature does not exceed normal room temperature, but for best operation, the switch should be replaced. Contact your HP­authorized LAN dealer, or use the electronic support services from HP to get assistance. See the Customer Support/Warranty card for more information.
Try the following procedures:
• For the indicated port, verify that both ends of the cabling, at the switch and the connected device, are connected properly.
on
• Verify the connected device and switch are both powered
• Verify that you have used the correct cable type for the connection.
- for twisted-pair connections, in general, for connecting an end node to the switch, use “straight- through” cable; for connecting MDI-X ports on hubs or other switches, use “crossover” cable.
- for fiber-optic connections, verify that the transmit port on the switch is connected to the receive port on the connected device, and the switch receive port is connected to the transmit port on the connected device.
• Verify that the port has not been disabled through a switch configuration change.
and operating correctly.
Troubleshooting
The port may be improperly configured
You can use the console interface, or, if you have configured an IP address on the switch, use the web browser interface, or HP TopTools for Hubs & Switches network management software to determine the state of the port and re-enable the port if necessary.
• If the other procedures don’t resolve the problem, try using a different port or a different cable.
Use the switch console, through the Status and Counters Menu, to see if the port is part of a switch mesh (Switch 1600M only) or to see if Spanning Tree is enabled on the switch, and to see if the port may have been put into a “blocking” state by those features. Also check the Port Status screen from the Status and Counters Menu to see if the port has been configured as “disabled”. Other switch features that may affect the port operation include VLANs and IGMP. Use the switch console to see how the port is configured for these features.
For software troubleshooting tips, see chapter 8, “Troubleshooting” in the
and Configuration Guide
3-6
Management
that came with your switch.
Page 47
Troubleshooting
Proactive Networking
Proactive Networking
The Switch 1600M and 2424M have built-in management capabilities that proactively help you manage your network including:
finding and helping you fix the most common network error conditions
(for example, faulty network cabling, and non-standard network topolo­gies)
informing you of the problem with clear, easy-to-understand messages
recommending network configuration changes to enhance the perfor-
mance of your network
The following interfaces provide tests, indicators, and an event log that can be used to monitor the switch and its network connections and to help you take advantage of these proactive networking features:
HP TopTools for Hubs & Switches - an SNMP-based network management
tool that is included with your switch.
A graphical web browser interface that you can use to manage your switch
from a PC running a supported web browser, for example Microsoft Internet Explorer, and Netscape Communicator.
A full-featured easy-to-use console interface that you can access by
merely connecting a standard terminal or PC running a terminal emulator
to the switch’s console port. The cable to make that connection is provided with your switch. The console interface is also accessible through a telnet connection.
Troubleshooting
See chapter 8, “Troubleshooting”, in the Management and Configuration Guide that came with your switch for more information on using these
software tools to diagnose and manage your switch.
3-7
Page 48
Troubleshooting
Hardware Diagnostic Tests
Hardware Diagnostic Tests
Testing the Switch by Resetting It
If you believe that the switch is not operating correctly, you can reset the switch to test its circuitry and operating code. To reset a switch, either:
Unplug and plug in the power cord (power cycling)
Press the reset button on the front of the switch
Power cycling the switch and pressing the Reset button both cause the switch to perform its power-on selftest, which almost always will resolve any tempo­rary operational problems. These reset processes also cause any network traffic counters to be reset to zero, and cause the System Up Time timer to reset to zero. None of the reset procedures cause any changes to the switch configuration.
Checking the Switch LEDs
The selftest passes if the Fault and Self Test LEDs on the front of the switch go off after approximately 30 to 45 seconds. (For the Switch 1600M, the duration depends on whether a module is installed in the switch.) If these LEDs stay on longer than 60 seconds or begin blinking, the switch may have to be replaced.
See “Diagnosing With the LEDs” on page 3-4 for information on interpreting the LED patterns.
Troubleshooting
Checking Console Messages
Useful diagnostic messages may be displayed on the console screen when the switch is reset. As described in chapter 2 under step 7, “Connect a Console to the Switch”, connect a PC running a VT-100 terminal emulator program or a standard VT-100 terminal to the switch’s Console Port and configure it to run at 9600 baud, and with the other terminal communication settings shown on page 2-15. Then, when you reset the switch, note the messages that are displayed. Additionally, you can check the switch event log, which can be accessed from the console Main Menu.
3-8
Page 49
Troubleshooting
Hardware Diagnostic Tests
Testing Twisted-Pair Cabling
If you think the cable should work but still isn’t working, it may not be compatible with the IEEE 802.3 Type 10Base-T or 100Base-TX standards. The twisted-pair cables attached to the Switch 1600M and 2424M must be compat­ible with these standards. To verify that your cable is compatible with these standards, use a qualified cable test device.
HP also offers a wire testing service. Contact your HP-authorized LAN dealer or your local HP sales office for more information.
Note Make sure that you are using the correct cabling type for each connection.
The switch 10 Mbps and 100 Mbps UTP ports are all wired as MDI-X. For connecting end nodes and other MDI-type devices, use “straight-through” cable. For connecting hubs, other switches, and other MDI-X devices, use “crossover” cable. See appendix B, “Cables and Connectors” for the pinouts for these cables.
Testing Switch-to-Device Network Communications
You can perform the following communication tests to verify that the network is operating correctly between the switch and any connected device that can respond correctly to the communication test.
Link Test -- a physical layer test that sends IEEE 802.2 test packets to any
device identified by its MAC address
Ping Test -- a network layer test used on IP networks that sends test
packets to any device identified by its IP address
These tests can be performed through the switch console interface from a terminal connected to the switch or through a telnet connection, or from the switch’s web browser interface. See the Management and Configuration Guide that came with your switch for more information.
These tests can also be performed from an SNMP network management station running a program that can manage the switch, for example, HP TopTools for Hubs & Switches.
Troubleshooting
3-9
Page 50
Troubleshooting
Restoring the Factory Default Configuration
Testing End-to-End Network Communications
Both the switch and the cabling can be tested by running an end-to-end communications test -- a test that sends known data from one network device to another through the switch. For example, if you have two PCs on the network that have LAN adapters between which you can run a link-level test or Ping test through the switch, you can use this test to verify that the entire communication path between the two PCs is functioning correctly. See your LAN adapter documentation for more information on running a link test or Ping test.
Restoring the Factory Default Configuration
As part of your troubleshooting process, it may become necessary to return the switch configuration to the factory default settings. This process momen­tarily interrupts the switch operation, clears any passwords, clears the console event log, resets the network counters to zero, performs a complete self test, and reboots the switch into its factory default configuration including deleting an IP address.
To execute the factory default reset, perform these steps:
1. Using pointed objects, simultaneously press both the Reset and Clear buttons on the front of the switch.
2. Continue to press the Clear button while releasing the Reset button.
Troubleshooting
3. When the Self Test LED begins to blink, release the Clear button.
The switch will then complete its self test and begin operating with its configuration restored to the factory default settings.
3-10
Page 51
Troubleshooting
HP Customer Support Services
HP Customer Support Services
If you are still having trouble with your switch, Hewlett-Packard offers support 24 hours a day, seven days a week through the use of a number of automated electronic services. See the Customer Support/Warranty booklet that came with your switch for information on how to use these services to get technical support. The HP networking products World Wide Web site, http://www.hp.com/go/procurve also provides up-to-date support informa­tion.
Additionally, your HP-authorized network reseller can provide you with assis­tance, both with services that they offer and with services offered by HP.
Before Calling Support
Before calling your networking dealer or HP Support, to make the support process most efficient, you first should have retrieved the following informa­tion:
Information Item Information Location
• product identification the front of the switch: Switch 1600M (HP J4120A) or Switch 2424M (HP J4093A)
• switch’s OS (software)
version
• copy of the switch config-
uration
• copy of the switch Event
Log
• copy of the switch status
and counters information, including the detailed counters for the problem port(s)
• copy of your network
topology map, including network addresses as­signed to the relevant de­vices
switch console: Main Menu –> 1. Status and Counters –>
1. General System Information (Firmware revision field)
switch console: Main Menu –> 5. Diagnostics –>
3. Browse Configuration File
switch console: Main Menu –> 4. Event Log
switch console: Main Menu –> 1. Status and Counters –>
4. Port Status and 5. Port Counters
your network records
Troubleshooting
3-11
Page 52
Page 53
Specifications
Except where otherwise noted, the following specifications apply to both the Switch 1600M and the Switch 2424M.
Physical
Width: 44.2 cm (17.4 in)
Depth: 33.5 cm (13.2 in)
Height: 6.6 cm (2.6 in)
Weight:
• Switch 1600M
• Switch 2424M
A
4.5 kg (9.9 lbs)
4.7 kg (10.4 lbs)
Electrical
The Switch 1600M and 2424M automatically adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz.
AC voltage: 100–127 volts 200–240 volts
Maximum current:
• Switch 1600M
• Switch 2424M
Frequency range: 50/60 Hz 50/60 Hz
1.0 A
2.0 A
0.6 A
1.0 A
Environmental
Operating Non-Operating
Temperature: 0°C to 55°C (32°F to 131°F) -40°C to 70°C (-40°F to 158°F)
Relative humidity: (non-condensing)
Maximum altitude: 4.6 Km (15,000 ft) 4.6 Km (15,000 ft)
15% to 95% at 40°C (104°F) 15% to 90% at 65°C (149°F)
Specifications
A-1
Page 54
Specifications
Acoustic
Switch 1600M: Geraeuschemission LwA=54 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Switch 2424M: Geraeuschemission LwA=55 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19
Connectors
The 10/100 Mbps RJ-45 twisted-pair ports are compatible with the
IEEE 802.3u 100Base-TX and IEEE 802.3 Type 10Base-T standards.
The 100 Mbps SC fiber-optic ports on the 100Base-FX Switch Module are
compatible with the IEEE 802.3u 100Base-FX standard.
The 10 Mbps ST fiber-optic ports on the 10Base-FL Switch Module are
compatible with the IEEE 802.3 Type 10Base-FL standard.
The 1000 Mbps SC fiber-optic ports on the Gigabit-SX and Gigabit-LX
Switch Modules, and on the Gigabit-SX and Gigabit-LX transceivers for the Gigabit Stacking Module are compatible with the IEEE 802.3z Gigabit­SX and Gigabit-LX standards.
Safety
EN60950 / IEC 950
CSA 22.2 No. 950
UL 1950
Specifications
A-2
Page 55
Connectors and Cables
This appendix includes switch connector information and network cable information for cables that should be used with the Switch 1600M and 2424M, including minimum pin-out information and specifications for twisted-pair cables.
Note Incorrectly wired cabling is the most common cause of problems for LAN
communications. HP recommends that you work with a qualified LAN cable installer for assistance with your cabling requirements.
Connectors
Twisted Pair
B
Connectors and Cables
The fixed RJ-45 10/100Base-T ports on the switches and the ports on the
10/100Base-T Module accept 100-ohm unshielded and shielded twisted­pair cable with RJ-45 connectors as described on the next page.
Fiber-Optic
The ports on the 10Base-FL Module transmit at 820 nm wavelength, and
accept the multimode fiber-optic cables for 10Base-FL described on the next page.
The ports on the 100Base-FX Module transmit at 1300 nm wavelength,
and accept the multimode fiber-optic cables for 100Base-FX described on the next page.
The ports on the Gigabit-SX Module and the Gigabit-SX Transceiver
transmit at 850 nm wavelength, and accept the multimode fiber-optic cables for Gigabit-SX described on the next page.
The ports on the Gigabit-LX Module and Gigabit-LX Transceiver
transmit at 1300 nm wavelength, and accept the single mode or multimode fiber-optic cables for Gigabit-LX described on the next page.
B-1
Page 56
Connectors and Cables
Connectors and Cables
Cables
Twisted-Pair
10 Mbps Operation Category 3, 4, or 5 100-ohm unshielded twisted-pair (UTP)
or shielded twisted-pair (STP) cable, complying with IEEE
802.3 Type 10Base-T specifications, fitted with RJ-45 connectors
100 Mbps Operation Category 5 100-ohm UTP or STP cable, complying with
IEEE 802.3u 100Base-TX specifications, fitted with RJ-45 connectors
Fiber-Optic
10Base-FL 62.5/125 µm or 50/125 µm (core/cladding) diameter, graded-
index, multimode fiber-optic cables, complying with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a respec­tively, fitted with ST connectors
100Base-FX 62.5/125 µm or 50/125 µm (core/cladding) diameter, graded-
index, multimode fiber-optic cables, complying with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a respec­tively, fitted with SC connectors
Gigabit-SX 62.5/125 µm or 50/125 µm (core/cladding) diameter, graded-
index, multimode fiber-optic cables, complying with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a respec­tively, fitted with SC connectors
Gigabit-LX single mode fiber-optic cables, complying with the ITU-T
G.652 and ISO/IEC 793-2 Type B1 standards, fitted with SC connectors
OR
62.5/125 µm or 50/125 µm (core/cladding) diameter, graded­index, multimode fiber-optic cables, complying with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a respec­tively, fitted with SC connectors
Note: Multimode fiber-optic cabling may be used for a Gigabit-LX application, but a mode conditioning patch cord may be needed. See the Installation Guide that came with your module for more information.
B-2
Page 57
Connectors and Cables
Twisted-Pair Cable/Connector Pin-Outs
Twisted-Pair Cable/Connector Pin-Outs
The RJ-45 connectors on the 10/100Base-TX ports on the Switch 1600M and 2424M are all wired as MDI-X ports. The type of twisted-pair cable you connect
to these ports (either “straight through” or “crossover”) depends on the type of device at the other end of the cable.
The rule is, when connecting same-type ports together (for example MDI­X-to-MDI-X), use crossover cable; when connecting opposite-type ports together (for example MDI-X-to-MDI), use straight-through cable.
These additional rules apply:
All twisted-pair wires used for 10 Mbps and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin Assignments” later in this appendix for a listing of the signals used on each pin.
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
unshielded twisted-pair cable, as supported by the IEEE 802.3 Type 10Base-T standard.
For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP or
STP cable only, as supported by the IEEE 802.3u Type 100Base-TX stan­dard.
Connectors and Cables
B-3
Page 58
Connectors and Cables
Connectors and Cables
Twisted-Pair Cable/Connector Pin-Outs
Twisted-Pair Cable for Switch (MDI-X) to Computer (MDI) 10 Mbps or 100 Mbps Network Connection
To connect PCs or other MDI network devices to the switch 10 Mbps or 100 Mbps MDI-X ports, use a “straight-through” cable.
Connector “A” Connector “B”
Straight-Through Cable
white/orange
orange/white
white/green
green/white
Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2
on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6 on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable.
.
B-4
Page 59
Connectors and Cables
Twisted-Pair Cable/Connector Pin-Outs
Twisted-Pair Cable for Switch (MDI-X) to Hub or Switch (MDI-X) 10 Mbps or 100 Mbps Network Connection
To connect hubs or switches or other MDI-X network devices to the switch 10 Mbps or 100 Mbps MDI-X ports, use a “crossover” cable.
Connector “A”
Crossover Cable
white/orange
orange/white
white/green
green/white
Connector “B”
Connectors and Cables
Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6
on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2 on connector “B”.
Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable.
.
B-5
Page 60
Connectors and Cables
Twisted-Pair Cable/Connector Pin-Outs
Twisted-Pair Cable Pin Assignments for 10 Mbps or 100 Mbps Operation
Twisted-Pair Straight-Through Cable
Switch End (MDI-X) Computer, Transceiver, or
Other MDI Port End
Connectors and Cables
Signal Pins Pins Signal
receive + receive ­transmit + transmit -
1 2 3 6
1 2 3 6
transmit + transmit ­receive + receive -
Twisted-Pair Cross-Over Cable
Switch End (MDI-X) Hub or Switch Port, or Other
MDI-X Port End
Signal Pins Pins Signal
receive + receive ­transmit + transmit -
1 2 3 6
6 3 2 1
transmit ­transmit + receive ­receive +
B-6
Page 61
Safety and EMC Regulatory Statements
!
Safety Information
Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product.
WARNING A WARNING in the manual denotes a hazard that can cause injury
or death.
CAUTION A CAUTION in the manual denotes a hazard that can damage
equipment.
Do not proceed beyond a WARNING or CAUTION notice until you have understood the hazardous conditions and have taken appro­priate steps.
C
Safety and EMC Regulatory
Statements
Grounding
These are safety class I products and have protective earthing terminals. There must be an uninterruptible safety earth ground from the main power source to the product’s input wiring terminals, power cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, disconnect the power cord until the ground has been restored.
For LAN cable grounding:
If your LAN covers an area served by more than one power distribu-
tion system, be sure their safety grounds are securely interconnected.
LAN cables may occasionally be subject to hazardous transient volt-
ages (such as lightning or disturbances in the electrical utilities power grid). Handle exposed metal components of the network with caution.
Servicing
There are no user-serviceable parts inside these products. Any servicing, adjustment, maintenance, or repair must be performed only by service-trained personnel.
These products do not have a power switch; they are powered on when the power cord is plugged in.
C-1
Page 62
Safety and EMC Regulatory Statements
!
Informations concernant la sécurité
Informations concernant la sécurité
Symbole de référence à la documentation. Si le produit est marqué de ce symbole, reportez-vous à la documentation du produit afin d'obtenir des informations plus détaillées.
WARNING Dans la documentation, un WARNING indique un danger susceptible
d'entraîner des dommages corporels ou la mort.
CAUTION Un texte de mise en garde intitulé CAUTION indique un danger suscep-
tible de causer des dommages à l'équipement.
Ne continuez pas au-delà d'une rubrique WARNING ou CAUTION avant d'avoir bien compris les conditions présentant un danger et pris les mesures appropriées.
Cet appareil est un produit de classe I et possède une borne de mise à la terre. La source
Statements
Safety and EMC Regulatory
d'alimentation principale doit être munie d'une prise de terre de sécurité installée aux bornes du câblage d'entrée, sur le cordon d'alimentation ou le cordon de raccordement fourni avec le produit. Lorsque cette protection semble avoir été endommagée, débrancher le cordon d'alimentation jusqu'à ce que la mise à la terre ait été réparée.
Mise à la terre du câble de réseau local:
si votre réseau local s'étend sur une zone desservie par plus d'un système de
distribution de puissance, assurez-vous que les prises de terre de sécurité soient convenablement interconnectées.
Les câbles de réseaux locaux peuvent occasionnellement être soumis à des
surtensions transitoires dangereuses (telles que la foudre ou des perturba­tions dans le réseau d'alimentation public). Manipulez les composants métalliques du réseau avec précautions.
Aucune pièce contenue à l'intérieur de ce produit ne peut être réparée par l'utilisateur. Tout dépannage, réglage, entretien ou réparation devra être confié exclusivement à un personnel qualifié.
Cet appareil ne comporte pas de commutateur principal ; la mise sous tension est effectuée par branchement du cordon d'alimentation.
C-2
Page 63
Safety and EMC Regulatory Statements
!
Hinweise zur Sicherheit
Hinweise zur Sicherheit
Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten.
WARNING Eine WARNING in der Dokumentation symbolisiert eine Gefahr, die
Verletzungen oder sogar Todesfälle verursachen kann.
CAUTION CAUTION in der Dokumentation symbolisiert eine Gefahr, die dis
Gerät beschädigen kann.
Fahren Sie nach dem Hinweis WARNING oder CAUTION erst fort, nachdem Sie den Gefahrenzustand verstanden und die entsprech­enden Maßnahmen ergriffen haben.
Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdung­sterminal. Der Betrieb des Geräts erfordert eine ununterbrochene Sicherheitserdung von der Hauptstromquelle zu den Geräteingabeterminals, den Netzkabeln oder dem mit Strom belieferten Netzkabelsatz voraus. Sobald Grund zur Annahme besteht, daß der Schutz beeinträchtigt worden ist, das Netzkabel aus der Wandsteckdose herausz­iehen, bis die Erdung wiederhergestellt ist.
Safety and EMC Regulatory
Statements
Für LAN-Kabelerdung:
Wenn Ihr LAN ein Gebiet umfaßt, das von mehr als einem Stromverteilungs-
system beliefert wird, müssen Sie sich vergewissern, daß die Sicherheitserdungen fest untereinander verbunden sind.
LAN-Kabel können gelegentlich gefährlichen Übergangsspannungen aus-
gesetzt werden (beispielsweise durch Blitz oder Störungen in dem Starkstromnetz des Elektrizitätswerks). Bei der Handhabung exponierter Metallbestandteile des Netzwerkes Vorsicht walten lassen.
Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile. Wartungs-, Anpassungs-, Instandhaltungs- oder Reparaturarbeiten dürfen nur von geschultem Bedienungspersonal durchgeführt werden.
Dieses Gerät hat keinen Netzschalter; es wird beim Anschließen des Netzkabels eingeschaltet.
C-3
Page 64
Safety and EMC Regulatory Statements
!
Considerazioni sulla sicurezza
Considerazioni sulla sicurezza
Simbolo di riferimento alla documentazione. Se il prodotto è contras­segnato da questo simbolo, fare riferimento alla documentazione sul prodotto per ulteriori informazioni su di esso.
WARNING La dicitura WARNINGdenota un pericolo che può causare lesioni o
morte.
CAUTION La dicituraCAUTION denota un pericolo che può danneggiare le
attrezzature.
Non procedere oltre un avviso di WARNING o di CAUTIONprima di aver compreso le condizioni di rischio e aver provveduto alle misure del caso.
Questo prodotto è omologato nella classe di sicurezza I ed ha un terminale protettivo
Statements
Safety and EMC Regulatory
di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non interrompibile che vada dalla fonte d'alimentazione principale ai terminali d'entrata, al cavo d'alimentazione oppure al set cavo d'alimentazione fornito con il prodotto. Ogniqualvolta vi sia probabilità di danneggiamento della protezione, disinserite il cavo d'alimentazione fino a quando il collegaento a terra non sia stato ripristinato.
Per la messa a terra dei cavi LAN:
se la vostra LAN copre un'area servita da più di un sistema di distribuzione
elettrica, accertatevi che i collegamenti a terra di sicurezza siano ben collegati fra loro;
i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni
transitorie (ad esempio, provocate da lampi o disturbi nella griglia d'alimen­tazione della società elettrica); siate cauti nel toccare parti esposte in metallo della rete.
Nessun componente di questo prodotto può essere riparato dall'utente. Qualsiasi lavoro di riparazione, messa a punto, manutenzione o assistenza va effettuato esclusi­vamente da personale specializzato.
Questo apparato non possiede un commutatore principale; si mette scotto tensione all'inserirsi il cavo d'alimentazione.
C-4
Page 65
Safety and EMC Regulatory Statements
!
Consideraciones sobre seguridad
Consideraciones sobre seguridad
Símbolo de referencia a la documentación. Si el producto va marcado con este símbolo, consultar la documentación del producto a fin de obtener mayor información sobre el producto.
WARNING Una WARNING en la documentación señala un riesgo que podría
resultar en lesiones o la muerte.
CAUTION Una CAUTION en la documentación señala un riesgo que podría
resultar en averías al equipo.
No proseguir des pués de un símbolo de WARNING o CAUTION hasta no haber entendido las condiciones peligrosas y haber tomado las medidas apropiadas.
Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde
la toma de alimentación eléctrica hasta las bornas de los cables de entrada del aparato, el cable de alimentación o el juego de cable de alimentación suministrado. Si existe la probabilidad de que la protección a tierra haya sufrido desperfectos, desenchufar el cable de alimentación hasta haberse subsanado el problema.
Safety and EMC Regulatory
Statements
Puesta a tierra del cable de la red local (LAN):
Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una
red de distribución de electricidad, cerciorarse de que las puestas a tierra estén conectadas entre sí de modo seguro.
Es posible que los cables de la LAN se vean sometidos de vez en cuando a
voltajes momentáneos que entrañen peligro (rayos o alteraciones en la red de energía eléctrica). Manejar con precaución los componentes de metal de la LAN que estén al descubierto.
Este aparato no contiene pieza alguna susceptible de reparación por parte del usuario. Todas las reparaciones, ajustes o servicio de mantenimiento debe realizarlos sola­mente el técnico.
Este producto no tiene interruptor de potencia; se activa cuando se enchufa el cable de alimentación.
C-5
Page 66
Safety and EMC Regulatory Statements
Safety Information (Japan)
Safety Information (Japan)
Statements
Safety and EMC Regulatory
C-6
Page 67
Safety and EMC Regulatory Statements
Safety Information (China)
Safety Information (China)
Safety and EMC Regulatory
Statements
C-7
Page 68
Safety and EMC Regulatory Statements
EMC Regulatory Statements
EMC Regulatory Statements
U.S.A.
FCC Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference when the equipment is operated in a commercial environment. This equipment gener­ates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment in a residential area may cause interference in which case the user will be required to correct the interference at his own expense.
Statements
Canada
Safety and EMC Regulatory
This product complies with Class A Canadian EMC requirements.
Australia/New Zealand
This product complies with Australia/New Zealand EMC Class A requirements.
Japan
VCCI Class A
C-8
Page 69
Korea
Taiwan
Safety and EMC Regulatory Statements
EMC Regulatory Statements
Safety and EMC Regulatory
Statements
C-9
Page 70
Safety and EMC Regulatory Statements
EMC Regulatory Statements
European Community
Statements
Safety and EMC Regulatory
C-10
Page 71
Index
Numerics
10/100Base-TX ports
location on switch … 1-2 100 LED … 1-3 100Base-FX
connections, length limitations … 2-4
ports, cables used with … 2-4, B-2 100Base-TX
connections, length limitations … 2-4
ports, cables used with … 2-4 10Base-FL
connections, length limitations … 2-4
ports, cables used with … 2-4, B-2 10Base-T
connections, length limitations … 2-4
ports, cables used with … 2-4
A
Act LED … 1-3 address learning … 1-8 address table
automatic address learning … 1-8
filtering out traffic … 1-8
flooding traffic … 1-8
forwarding traffic … 1-8
moves and changes … 1-8
operation … 1-8
B
back of switch
description … 1-6
power connector … 1-6 backbone switch
topology with … 2-19 bandwidth, how switch enhances … 1-9 basic troubleshooting tips … 3-2 Bootp
for in-band access … 2-15 buttons
Clear button … 1-5
Mode Select button … 1-4
Reset button … 1-5
C
cabinet
mounting the switch in … 2-10
cables
100Base-FX
connections … 2-4
fiber-optic cable specifications … B-2 100Base-TX connections … 2-4 10Base-FL
connections … 2-4
fiber-optic cable specifications … B-2 10Base-T connections … 2-4 connecting cables to switch ports … 2-14 effects of non-standard cables … 3-2 fiber-optic, specifications … B-2 Gigabit-LX
connections … 2-4
fiber-optic cable specifications … B-2 Gigabit-SX
connections … 2-4
fiber-optic cable specifications … B-2 incorrect network connections … 3-2 infrastructure requirements … 2-4 length limitations … 2-4 required types … 2-4 serial, for direct console connection … 2-16 twisted-pair connector pin-outs … B-3 twisted-pair, specifications … B-2
cables, twisted pair
category 3, 4, 5 … B-3 cross-over cable pin-out … B-6 MDI-X to MDI connections … B-4 MDI-X to MDI-X connections … B-5 pin-outs … B-6 straight-through cable pin-out … B-6 switch-to-computer connection … B-4 switch-to-switch or hub connection … B-5
cabling infrastructure … 2-4
Index
Index – 1
Page 72
Clear button
deleting passwords … 1-5 description … 1-5 location on switch … 1-2, 1-5 restoring factory default configuration … 1-5,
3-10
configuration
restoring factory defaults … 1-5, 3-10 connecting the switch to a power source … 2-13 connector specifications … A-2 console
checking messages during
troubleshooting … 3-8 displaying the Main menu … 2-16 features … 2-15 how to connect in-band … 2-15 how to connect out-of-band … 2-15 serial cable connection … 2-16 telnet access … 2-16 terminal configuration … 2-15
console port
description … 1-5 location on switch … 1-2, 1-5
cross-over cable
pin-out … B-6
D
deleting passwords … 1-5 description
back of switch … 1-6
Index
front of switch … 1-2 LEDs … 1-3 switch … 1-1
desktop switch
sample topology … 2-17
DHCP
for in-band access … 2-15
diagnostic tests … 3-8
checking the console messages … 3-8 checking the LEDs … 3-8 end-to-end connectivity … 3-10 testing the switch only … 3-8 testing twisted-pair cabling … 3-9
E
electrical specifications, switch … A-1 EMC regulatory statements … C-8 environmental specifications, switch … A-1
F
factory default configuration, restoring … 1-5, 3-10 Fan Status LED … 1-3 Fault LED … 1-3
behavior during self test … 2-9 behaviors … 1-3 flashing definition … 1-3 location on switch … 1-2
showing error conditions … 3-4 Fdx LED … 1-3 features
console … 2-15
Switch 1600M and 2400M … 1-7 fiber-optic cables … B-2
100Base-FX … B-2
10Base-FL … B-2
Gigabit-LX … B-2
Gigabit-SX … B-2 filtering out traffic … 1-8 flashing LEDs
error indications … 3-4 flooding traffic … 1-8 forwarding traffic … 1-8 front of switch
10/100Base-TX ports … 1-2
Clear button … 1-5
console port … 1-5
description … 1-2
LEDs … 1-3
Mode Select button and LEDs … 1-4
network ports … 1-2
Reset button … 1-5
slot for switch modules … 1-2
G
Gigabit-LX
connections, length limitations … 2-4
ports, cables used with … 2-4, B-2 Gigabit-SX
connections, length limitations … 2-4
ports, cables used with … 2-4, B-2
2 – Index
Page 73
H
horizontal surface, mounting switch on … 2-12 hot swapping
resetting the switch for new module type … 2-20 switch modules … 2-20
I
in-band console access
types of … 2-15 included parts … 2-1 incorrect network connections … 3-2 installation
connecting the switch to a power source … 2-13
horizontal surface mounting … 2-12
network cable requirements … 2-4
optional modules … 2-6
precautions … 2-3
rack or cabinet mounting … 2-10
site preparation … 2-4
summary of steps … 2-2
Switch 1600M and 2400M … 2-1
wall mounting … 2-13
L
LEDs
10/100Base-TX ports … 1-4
100 … 1-3
Act … 1-3
behavior during self test … 2-9
checking during troubleshooting … 3-8
descriptions of … 1-3
error indications … 3-4
Fan Status … 1-3
Fault … 1-3
behavior during self test … 2-9
showing error conditions … 3-4 Fdx … 1-3 flashing definition … 1-3 Link … 1-4 location on switch … 1-2 Mode
description … 1-4
selecting the display … 1-4 mode select indicators … 1-3 Module Status … 1-3 on switch … 1-3 on switch modules … 1-4 Power … 1-3
behavior during self test … 2-9 Self Test … 1-3
behavior during self test … 2-9
length limitations
100Base-FX connections … 2-4 100Base-TX connections … 2-4 10Base-FL connections … 2-4 10Base-T connections … 2-4 Gigabit-LX connections … 2-4 Gigabit-SX connections … 2-4
Link LEDs … 1-4 link test … 3-9
M
Main menu, console
displaying … 2-16
MDI-X to MDI network cable … B-4 MDI-X to MDI-X network cable … B-5 Mode LEDs
description … 1-4 selecting the display … 1-4
Mode Select
button … 1-4 indicator LEDs … 1-3–1-4
Module Status LED … 1-3 modules
switch modules
hot swapping … 2-20
installing … 2-6
LEDs … 1-4
mounting the switch
in a rack or cabinet … 2-10
precautions … 2-3 on a horizontal surface … 2-12 on a wall … 2-13
precautions … 2-13
moves and changes
effect on address table … 1-8
Index
Index – 3
Page 74
N
network cables
100Base-FX connections … 2-4 100Base-TX connections … 2-4 10Base-FL connections … 2-4 10Base-T connections … 2-4 fiber-optic, specifications … B-2 Gigabit-LX connections … 2-4 Gigabit-SX connections … 2-4 incorrect connections … 3-2 required types … 2-4 twisted-pair connector pin-outs … B-3 twisted-pair, specifications … B-2
network devices
connecting to the switch … 2-14
network ports
connecting to … 2-14 LEDs for … 1-4 location on switch … 1-2 standards compliance … A-2 types of … 1-2, 2-4
non-standard network cables, effects … 3-2
O
out-of-band console access … 2-16
power source
connecting the switch to … 2-13
precautions
mounting the switch … 2-3 power requirements … 2-3
preparing the installation site … 2-4 Proactive Network tools
diagnostics with … 3-7
R
rack
mounting precautions … 2-3 mounting the switch in … 2-10
rebooting the switch
to initialize new module type … 2-6
regulatory statements … C-8 Reset button
description … 1-5 location on switch … 1-2, 1-5 restoring factory default configuration … 3-10
resetting the switch
factory default reset … 3-10 for module hot swap … 2-20 location of Reset button … 1-5 troubleshooting procedure … 3-8
P
parts, included with the switch … 2-1
Index
passwords, deleting … 1-5 physical specifications, switch … A-1 Ping test … 3-9 pin-outs
twisted-pair cables … B-3
port LEDs
Link … 1-4 Mode … 1-4
ports
10/100Base-TX, location on switch … 1-2 connecting to … 2-14 console … 1-5, 2-15
network connections … 2-14 power connector … 1-6 Power LED … 1-3
behavior during self test … 2-9
behaviors … 1-3
location on switch … 1-2
S
safety and regulatory statements … C-1 safety specifications … A-2 segment switch
sample topology … 2-18 selecting the Mode LED display … 1-4 self test
Fault LED behavior … 2-9
LED behavior during … 2-9
Power LED behavior … 2-9 Self Test LED … 1-3
behavior during factory default reset … 3-10
behavior during self test … 2-9 serial cable
for direct console connection … 2-16 slot for switch module
location on Switch 1600M … 1-2
location on Switch 2424M … 1-6
4 – Index
Page 75
specifications
connectors … A-2 electrical … A-1 environmental … A-1 physical … A-1 safety … A-2
straight-through cable
pin-out … B-6
summary
of cables used with the switch … 2-4 of switch installation … 2-2
switch
connecting to a power source … 2-13 description … 1-1 electrical specifications … A-1 environmental specifications … A-1 features … 1-7 front panel description … 1-2 included parts … 2-1 LED descriptions … 1-3 mounting in a rack or cabinet … 2-10 mounting on a wall … 2-13 mounting on horizontal surface … 2-12 operation … 1-8 physical specifications … A-1
switch modules
booting the switch to initialize new module
type … 2-6 hot swapping … 2-20 installing … 2-6 LEDs description … 1-4 slot, location on Switch 1600M … 1-2 slot, location on Switch 2424M … 1-6
switch operation
address table … 1-8 description … 1-8 effect of VLANs … 1-9 filtering out traffic … 1-8 flooding traffic … 1-8 forwarding traffic … 1-8 network moves and changes … 1-8 simultaneous network communications … 1-9 verifying after installation … 2-8
T
telnet access to the console … 2-16 terminal configuration … 2-15 testing
checking the console messages … 3-8 checking the LEDs … 3-8 diagnostic tests … 3-8 end-to-end communications … 3-10 link test … 3-9 Ping test … 3-9 switch operation … 3-8 switch-to-device communications … 3-9
twisted-pair cabling … 3-9 tips for troubleshooting … 3-2 topologies
effects of improper topology … 3-2
samples of … 2-17 troubleshooting … 3-1
basic tips … 3-2
checking the console messages … 3-8
checking the LEDs … 3-8
common network problems … 3-2
diagnostic tests … 3-8
effects of improper topology … 3-2
effects of non-standard cables … 3-2
incorrect network connections … 3-2
link test … 3-9
Ping test … 3-9
Proactive Network tools … 3-7
restoring factory default configuration … 3-10
testing connections to other devices … 3-9
testing end-to-end communications … 3-10
testing the switch … 3-8
testing the twisted-pair cables … 3-9 twisted-pair cable
cross-over cable pin-out … B-6
pin-outs … B-3, B-6
straight-through cable pin-out … B-6
switch-to-computer connection … B-4
switch-to-switch or hub connection … B-5
testing … 3-9 twisted-pair cables … B-2
Index
Index – 5
Page 76
V
VLAN
effect on basic switch operation … 1-9
VT-100 terminal
serial cable connection for … 2-16
W
wall
mounting switch on … 2-13
Index
6 – Index
Page 77
Page 78
Page 79
Page 80
Technical information in this document is subject to change without notice.
©Copyright Hewlett-Packard Company
1998. All rights reserved. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws.
Printed in Singapore 12/98
Manual Part Number 5967-9953
*5967-9953*
Loading...