HP J3591A User Manual

Page 1
Secure console access ...
J3591A HP Secure Web Console
HP Manufacturing Part Number J3591-90101
Edition 2 E08/98 Printed in U.S.A.
USERS
SECURE
Password login
login name
password
Exit without loginlogin
Page 2
Copyright and trademark information
This document contains proprietary information which is protected by copyright. All rights reserved. No part of this document may be photocopied, reproduced or translated into another language without the prior written consent of Hewlett-Packard company.
© Copyright Hewlett-Packard Company, 1998. All rights reserved.
Publication Number Applicable Product
J3591-90101 J3591A Edition 2 August 1998
Warranty
The HP Secure Web Console (J3591A) has a one-year return-to-HP limited hardware and firmware warranty.
Hewlett-Packard warrants this product against defects in materials and workmanship for the duration ofthewarrantyperiod,commencingonthe date of purchase from HP or an HP-authorized reseller.
If your HP Secure Web Console requires warranty service, contact your HP-authorized reseller or local HP representative for assistance.
For defects that occur during the warranty period, HP will, at its option, either repair or replace the defective product, or refund the purchase price. For information on how to contact HP, consult the WEB site http:// www.hp.com/go/webconsole.
This warranty does not apply to defects resulting from improper or inadequate maintenance by the customer; customer-supplied software, interfacing, supplies, unauthorized modification or improper use, operation outside the published environmental specifications for the product, or improper site preparation or maintenance by the customer.
Disclaimer
The information contained in this document is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard.
Java™ is a registered trademark of Sun Microsystems Inc. Internet Explorer™ is a registered trademark of Microsoft Corporation. Netscape™ and Netscape Navigator™ are registered trademarks of Netscape Communication Corporation.
Pre-Installation notes:
You should have obtained an IP address and a subnet mask for the HP Secure Web Console, and know the name of the system to be administered.
The HP Secure Web Console comes with complete online support information on the World Wide Web at http:// www.hp.com/go/webconsole. Select “SUPPORT”, and “FAQ’s”, or “Downloading & Patches”, or “Troubleshooting Tools & Flowcharts”, and “Troubleshooting Flowcharts”. In the “FAQ’s”, check the list of supported WEB browsers (Internet Explorer™ or Netscape Navigator™) versions; on your WEB browser, enable Java™ and Java™ scripts.
Need Help? Follow the troubleshooting steps. For detailed information on support from the World Wide Web, refer to page 7 of this document.
Configuration Example:
2
3
Page 3
Hardware Installation
1. Connect the LAN RJ45 cable (diagram A).
2. Connect the external power adapter to a wall socket. The device performs hardware and firmware self-tests, then starts the software boot sequence.
3. Connect the power adapter (diagram B).
4. Connect the serial cable to the system console port
Note: Step C should be executed only after the Initial Configuration is completed.
Initial Configuration
Overview
The HP Secure Web Console comes with a pre-configured IP address 192.0.0.192. An Initial Configuration step is required to assign the final IP address to the HP Secure Web Console.
LAN cable
A
HP Secure Web Console
power LAN
LED Status
Solid amber, test in progress. Amber off, self-test passed. Amber stays on, self-test failed. Flashing green, network activity.
amber green
External
B
power adapter
Serial cable
C
from system
Warning: For security reasons, do not connect the serial cable (diagram C) until you have completed the configuration.
A. If you have a DHCP server, you first need to configure the following entry for the HP Secure WEB Console into the DHCP server configuration file:
To activate this entry, execute on the DHCP server: bootpd < DHCP configuration file >
When the HP Secure WEB Console is first powered-on, the DHCP server assigns to it the IP address mapped to its MAC address. This is only executed if the HP Secure WEB Console IP address is 192.0.0.192. Connect the serial cable to the console port (see graph C p. 4). From a PC or Workstation, run a browser with http://<Console IP address> and follow the instructions on the screen.
B. If you have no DHCP server, you need to connect to the HP Secure Web Console over the LAN using its 192.0.0.192 IP address.
Note: For this initial step, your HP Secure Web Console must be on the same physical LAN as the client_host (no intermediate IP router); you may temporarily connect the HP Secure Web Console to your client_host’ s LAN and move it to its final location only after the final IP address has been assigned to it. Note: Power-off any other devices having the same 192.0.0.192 IP address (Check that “ping 192.0.0.192” does not reply before you power-on the HP Secure WEB Console).
Run a web browser from a client_host (PC or a Workstation) on the same IP subnet as the HP Secure WEB Console.
1. Disable Proxies (use “no Proxies” or temporarily add
192.0.0.192 to the list of URLs for which no proxy is configured), enable Java™ and Java™ scripts.
2. Enter the following commands into either a DOS or UNIX window on the client_host (PC or Workstation where your browser is running) to configure the HP Secure Web Console and add it to the gateway list:
Example (
customize italics
): mac:ht=ether: \ ha=
0060b0a6021
:\
gw=
15.128.125.1
:\
ip=
15.128.175.190
:\
sm=
255.255.248.0
:\
ds=
15.0.48.4
:\
dn=
hplvod6
Field meaning:
hardware type: ether Hardware address (ethernet) gateway address WEB Console IP address subnet mask domain name server’ IP addr domain name of WEB console
4
5
Page 4
7. Access the device through your Web browser on the same subnet by typing the following URL: http://192.0.0.192.
8. Follow the instructions on the screen:
* User Parameters: configure a User Administrator * Network Parameters: Web Console IP address, system name
The Console will then reboot automatically.
9. Now you can connect the serial cable (diagram C p. 4).
Resetting the Configuration
Itmay be necessary to reset your HP SecureWeb Console to the factory settings if, for example, the password has been lost.
Warning! All configuration data will be lost.
1. Power off the console by unplugging the power cable.
2. Press the button on the top of the console (as shown in diagram D) and keep it pressed.
3. Power on the box by replugging the power cable.
4. Release the button after a couple of seconds.
Follow the Initial Configuration steps again.
a. route add 192.0.0.192 <client_host IP address>
Example: route add 192.0.0.192 15.128.122.12
b. ping 192.0.0.192. If ping is successful, follow the
instructions Step 7, else proceed with Step c below.
c.
a
rp -s 192.0.0.192
< WEB Console MAC_address>
The MAC address of the HP Secure Web Console is marked on the top of the device and also on the box used for shipment.
UNIX Workstations: 00:60:b0:22:3e:ae
PCs: 00-60-b0-22-3e-ae
format, as shown below:
Note: the MAC address must be entered in the appropriate
Note: During the configuration of your HP Secure Web Console,
you must configure an IP gateway in the “configure IP” screen. If you do not have a valid IP gateway, enter the same IP address as you entered for the HP Secure Web Console.
Button for
D
reset to factory settings
Support from the World Wide Web
HP provides product and support information from the World Wide Web to enable you to identify and resolve problems. You can access this site at:
World Wide Web Site Overview:
PRODUCT provides Product supported features:
- product brief
- sideshows presentation
SUPPORT: Installation & Documentation (on-line version of this guide) Troubleshooting Flowcharts to guide you step-by-step through web console problems Frequently Asked Questions (FAQs) about Product setup and usage Downloading & Patches allows you to upgrade from the WEB to the latest product revision HP Support Services & Warranty gives contacts within the HP support organization for technical assistance and a description of the HP warranty policy
SOLUTIONS provides other general Product information
Main Hints:
Use the Troubleshooting Flowcharts to identify your problem.
Use HP Support Services and Warranty to find out how to contact HP for technical assistance.
Upgrade to the latest Firmware from the Support WEB site (Downloading & Patches).
Use temporarily a regular terminal if your HP Secure WEB Console is defective.
HP Technical Assistance: You can find how to contact HP from the World Wide Web site http://www.hp.com/go/webconsole, under “Support” and “HP Support Services” menu. Before contacting HP, make sure you have the serial number of your HP Secure WEB Console.
http://www.hp.com/go/webconsole
6
7
Page 5
Safety information - Safety earth ground
Warning For your safety, always connect the J3591A to a grounded wall outlet.
Always use a power adaptor supplied by HP for this Product (see warning below the table). Ensure that the adaptor meets your country’s standards for safety. This equipment is disconnected from the power by removing the power adaptor from the power outlet. This means the equipment must be located close to a power outlet that is easily accessible
.
Warning: Only use power adaptors referenced by HP for this Product; Part Numbers are provided for each country on the World Wide Web at http://www.hp.com/go/ webconsole, under “Support”, then “FAQs”.
Regulatory information
For Canada: ICES-003
This product complies with Canadian Electromagnetic compatibility (EMC) Class A requirements.
Conforme à la Classe A des normes canadiennes de compatibilité électromagnétique (CEM).
For the United States
Warning: Federal Communications Commission (FCC) Radio Frequency Statement.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Hewlett-Packard’s system verification tests were conducted with HP-supported peripheral devices and cables, such as those received with your system. Changes or modifications to this equipment not expressly approved by Hewlett-Packard could void the user’s authority to operate the equipment.
Country Input Rating Output Rating
Australia, New Zealand, China 240 V/50 Hz 13 VDC@300 mA Europe, except UK and Ireland 230 V/50 Hz 13 VDC@300 mA Japan 100 V/50/60 Hz 13 VDC@300 mA Korea 220-240 V/50 Hz 13 VDC@625 mA South Africa, India 220-250 V/50 Hz 13 VDC@625 mA UK, Singapore, Ireland, Hong Kong 220-240 V/50 Hz 13 VDC@300 mA USA, Canada, LAR, Taiwan 110-127 VAC/60 Hz 13 VDC@300 mA
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that might cause undesired operation.
For Europe
French Ce produit appartient ä la Classe A. En environnement, ce produit peut engendrer
des interférences radioélectriques, auquel cas l’ utilisateur peut devoir prendre les mesures nécessaires.
German Dieses Produkt ist ein Produkt der Klasse A. In einer häuslichen Umgebung kann
dieses Produkt störende Strahlungen verursachen. In diesem Fall muß der Benutzer selbst entsprechende Maßnahmen ergreifen.
Spanish Este es un producto de Clase A. En un entorno doméstico, este producto puede
provocar interferencias de radio, en cuyo caso es posible que se le pida al usuario que tome las medidas adecuadas.
Italian Questo prodotto rientra nella Classe A. Utilizzato in un ambiente domestico potrebbe
causare interferenze in radio frequenza; nel caso in cui questo si verifichi, è necessa­rio che l’ utente adotti gli opportuni accorgimenti.