This document provides information for HP StorageWorks Data Replication Manager with HSG80 Array
Controller Software Version 8.7P that is not covered elsewhere in user documentation. Individuals responsible
for configuring, installing, and using the Data Replication Manager solution should refer to this document for
last-minute content.
For the latest version of these Release Notes and other Data Replication Manager documentation, access the
website at
link and the technical support page is displayed. Click manuals (guides, supplements, addendums, etc) for a
listing of related documentation.
warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for
incidental or consequential damages in connection with the furnishing, performance, or use of this material.
This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied,
reproduced, or translated into another language without the prior written consent of Hewlett-Packard. The information contained in this
document is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty
statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft®, MS Windows®, Windows®, and Windows NT® are U.S. registered trademarks of Microsoft Corporation.
UNIX® is a registered trademark of The Open Group.
Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided
“as is” without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard Company products are
set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional
warranty.
Data Replication Manager HSG80 ACS Version 8.7P Release Notes
Fifth Edition (March 2004)
Part Number: AA-RPJ2E-TE
2Data Replication Manager HSG80 ACS Version 8.7P Release Notes
Release Notes Contents
These release notes cover the following major topics:
■What’s New, page 4
— SAN Extension Products, page 4
— Controller Firmware Upgrade Path, page 4
— Operating System and Fibre Channel Switch Support, page 5
■Common Platform Issues, page 8
— Performance Considerations—Adding Target Unit Back to Remote Copy Sets, page 8
— Performance Considerations—Full Copy Operation, page 8
— Performance Considerations—Write History Log Merge, page 8
— SWCC and OpenView Management Appliance Limitations, page 8
— Using Switch Zoning to Prevent Crashes When Using VTDPY Host Display, page 8
— Invalid VTDPY Percentages, page 8
— Using Switch Zoning to Prevent Crashes When the 96-Connection Limit Is Exceeded,
page 9
Release Notes Contents
— I/O Pause During Fabric Reconfiguration, page 9
— Controller Saturation, page 9
— RAID 5 Remote Copy Set Target Drop, page 9
— Required Delay Time Before Failback, page 10
— Removing Targets from the Proper Controller, page 10
— Startup of Only One Fabric at a Time, page 10
— Intermittent Double Normalization After a Full Failback or Failback to New Hardware
Procedure, page 11
— Command Scripter Communication Loss Due to SCSI Error, page 11
— Waiting for Write History Logging Disks, page 11
— Association Sets, page 11
■Platform-Specific Issues, page 12
— HP HP-UX, page 12
— HP OpenVMS, page 12
— HP Tru64 UNIX, page 12
— IBM AIX, page 13
— Microsoft Windows 2000, page 13
— Microsoft Windows NT, page 15
— Novell NetWare, page 16
— Sun Solaris, page 18
3Data Replication Manager HSG80 ACS Version 8.7P Release Notes
What’s New
Intended Audience
This document is intended for customers who purchased or upgraded to the HP StorageWorks
Data Replication Manager (DRM) HGS80 Array Controller Software (ACS) Version 8.7P, and
for HP authorized service providers responsible for installing, configuring, and maintaining
DRM systems.
Related documentation
The following documents provide helpful information for running your DRM solution:
■HP StorageWorks Data Replication Manager HSG80 Version 8.7P Configuration Guide,
part number AA-RPHZF-TE
■HP StorageWorks Data Replication Manager HSG80 Version 8.7P Failover/Failback
Procedures Guide, part number AA-RPJ0E-TE
■HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Scripting User
Guide, part number EK-DRMSC-OA. E01
■HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Design Guide
Reference Guide, part number AA-RQ78C-TE
■HP StorageWorks Continuous Access and Data Replication Manager SAN Extensions
Reference Guide, part number AA-RU5CE-TE
■HP StorageWorks SAN Design Reference Guide, part number AA-RMPNL-TE
What’s New
The following sections summarize the major features, enhancements, and requirements of
using ACS Version 8.7P with DRM.
SAN Extension Products
Refer to the HP StorageWorks Continuous Access and Data Replication Manager SAN
Extensions Reference Guide for details on supported Fibre Channel over Internet Protocol
products. All WDM products are permitted with Continuous Access EVA and Data
Replication Manager.
Controller Firmware Upgrade Path
HP strongly recommends that the minimum version of DRM for new installations or upgrades
be ACS v8.7-3P. This version should be obtained from a direct install and not by overlaying
patches on earlier versions of 8.7P. For information on obtaining the appropriate ACS v8.7-3P
PCMCIA card, contact your HP service center.
The rolling upgrade is documented in the HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide. The procedure is designed to allow an array
controller software upgrade without the need for a server reboot. However, you must ensure
that all the latest drivers, and if applicable, the latest release of Secure Path are installed prior
to this upgrade. Installing the latest drivers may require the server to be rebooted. Information
on the latest supported drivers and Secure Path can be found in Table 1.
4Data Replication Manager HSG80 ACS Version 8.7P Release Notes
Operating System and Fibre Channel Switch Support
Support has been added for newer operating systems and switch firmware. Table 1 lists the
minimum hardware and software versions of items supported by those operating systems
compatible with Data Replication Manager running ACS v8.7P and subsequent updates.
Operating systems are listed by vendor in the left column. Each item in the same row, and
listed to the right, is supported by that operating system.
To use this table, select an operating system and operating system version, then move to the
right and select a Fibre Channel Adapter (FCA). Supported FCA firmware is located further to
the right, followed by the driver and Secure Path versions for the FCA. In the last column is a
brief statement about cluster support for that operating system and version.
Table 2 lists supported switches for the HSG80 controller with their approved version of
firmware when used for DRM. Be aware that a 2 Gb/sec switch is constrained by the HSG80
controller to 1 Gb/sec.
Table 1: Operating System Support Matrix
What’s New
Operating
SystemOS VersionFCA
HP
HP-UX
HP OpenVMS7.2-2 with
HP Tru64
UNIX
IBM-AIX
11.0 (32-bit with
0303 patch bundle)
11.11 (32-bit with
0603 patch bundle)
VMS722_
FIBRE_SCSIV0400
7.3 w i th
VMS73_
FIBRE_SCSIV0500
7.3-1 with
VMS731_
FIBRE_SCSIV0100
5.1a BL22 PK4
5.1b BL1 PK1
4.3.3, 5.1Cambex 1Gb PCI
A5158A 1Gb PCI
A6685A 1Gb HSC
A6795A 2Gb PCI
LP8000 or
LP9002 (FCA2354)
LP9802 (FCA2384)1.00x8 or
LP8000 or
LP9002 (FCA2354)
LP9802 (FCA2384) 1.00x8 or
(1000F)
Cambex 2Gb PCI
(2000F)
Adapter
Firmware
NativeNative3.0aSP1 or
3.81a4, 3.82a1,
3.91a1, or
3.92a0
1.81a1
3.81a4, 3.82a1,
3.91a1, or
3.92a0
1.81a1
2.01.381.5.20.2 2.0cv5.1 supports
Adapter
Driver
NativeNativeVMSCluster
NativeNativeTruClusters
1.5.23.22.0d
Secure
PathClustering
3.0bSP1
ServiceGuard v11.14
Max: 4 nodes
Max: 96 nodes
Max: 8 nodes
HACMP v4.5
5Data Replication Manager HSG80 ACS Version 8.7P Release Notes
What’s New
Table 1: Operating System Support Matrix (Continued)
Operating
System
Microsoft
Windows NT
(Intel)
Windows
2000
(32-bit)
Novell
NetWare
Sun Solaris2.6, 7, 8
OS VersionFCA
4.0 SP6a
5.0 SP2, SP3, SP4
5.1 SP6,
6.0 SP3
2.6, 7, 8
2.6, 7, 8, 9
8 or 9 Build 2QLA2202 cPCI 1Gb
Adapter
Firmware
LP8000 (KGPSA-CB)
LP952 (FCA2101)
LP9002DC (FCA2355)3.82a1 BIOS
QLA2340 (FCA2214)
or BL20P Mezzanine
card (not supported on
NT)
QLA2342
(FCA2214DC) or
BL20P Mezzanine card
(not supported on NT)
LP982 (FCA2408) (not
supported on NT)
LP9802 (FCA2404)
and LP9802DC
(FCA2404DC) (neither
supported on NT
QLA 2340 (FCA2210)1.296.50.z3.0c with
1
JNI FCI-1063 (32-bit
PCI)
SWSA4-SB 1 Gb
32-bit SBUS
JNI FC64-1063 (64-bit
Sbus)
QLA2202 Sbus 1Gb
(FCA2257S)
QLA2310 Sbus 2Gb
(FCA2257P)
(FCA2257C)
3.82a1
BIOS 1.60a5
3.82a1
BIOS1.61a2
3.91a1
BIOS1.63a1
1.61a2
3.91a1 BIOS
1.63a1
1.348.2.0.72
1.348.2.0.72
1.01a24.82a16
1.01a24.82a16
3.0.32.5.9-033.0c with
13.3.7
FC 1.18.3,
firmware comes
with driver
FC 1.18.5,
firmware comes
with driver
FC 1.18.5,
firmware comes
with driver
Adapter
Driver
4.81a94.0cNT - 2 nodes
4.82a14
4.82a16
4.82a9
4.82a14
4.82a16
4.11
Secure
Path
SP1
SP1
Clustering
Windows 2000
Server - none
Windows 2000
Advanced Server MSCS v1.1 & Oracle
9iRAC; Max: 2 nodes
Windows Server
2003, Enterprise
edition - MSCS &
Oracle 9iRAC; Max:
4 nodes
N5.1 supports NCS
V1.01
V6.0 supports NCS
v1.06,
Max: 6 nodes
Veritas Cluster
Services v2.0 or v3.5;
Max 16 nodes
Sun Clusters v2.2;
Max: 16 nodes
1.If used with 2 Gbps B-series switches, you must use the latest switch firmware (v2.2.1c, v3.1.1c, or 4.1.2b at time of publication).
6Data Replication Manager HSG80 ACS Version 8.7P Release Notes
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.