HP HLMP-1300, HLMP-1301, HLMP-1302, HLMP-1385, HLMP-1400 Datasheet

...
H
T-1 (3 mm) Diffused LED Lamps
Technical Data

Features

• High Intensity
• Choice of 4 Bright Colors
High Efficiency Red Orange Yellow High Performance Green
• Popular T-1 Diameter Package
• Selected Minimum Intensities
• Wide Viewing Angle
• General Purpose Leads
• Reliable and Rugged
• Available on Tape and Reel

Description

This family of T-1 lamps is widely used in general purpose indicator applications. Diffusants, tints, and optical design are balanced to yield superior light output and wide viewing angles. Several intensity choices are available in each color for increased design flexibility.
HLMP-130X Series HLMP-1385 HLMP-140X Series HLMP-1485 HLMP-1503 HLMP-1523 HLMP-1585 HLMP-K40X Series HLMP-K600

Package Dimensions

Part Minimum
Number Intensity Color
HLMP- Application (mcd) at 10 mA (Material)
1300 General Purpose 1.3 High Efficiency 1301 General Purpose 2.1 1302 High Ambient 3.4 1385 Premium Lamp 8.6 K400 General Purpose 1.3 Orange K401 High Ambient 2.1 K402 Premium Lamp 3.4 1400 General Purpose 1.4 Yellow 1401 General Purpose 2.2 1402 High Ambient 3.6 1485 Premium Lamp 5.7 1503 General Purpose 1.0 Green 1523 High Ambient 2.6 1585 Premium Lamp 4.2
[1]
K600
Note:
1. Please refer to Application Note 1061 for information comparing standard green and emerald green light output degradation.
General Purpose 1.0 Emerald Green
Red (GaAsP on GaP)
(GaAsP on GaP)
(GaAsP on GaP)
(GaP)
(GaP)
1-134
5964-9374E
Absolute Maximum Ratings at T
= 25°C
A
Parameter HER/Orange Yellow Green Units
Peak Forward Current 90 60 90 mA Average Forward Current DC Current
[2]
[1]
25 20 25 mA
30 20 30 mA Reverse Voltage (IR = 100 µA) 5 5 5 V Transient Forward Current
[4]
500 500 500 mA
(10 µsec Pulse) LED Junction Temperature 110 110 110 °C Operating Temperature Range -55 to +100 -55 to +100 -20 to +100 °C
Storage Temperature Range -55 to +100 Lead Soldering Temperature 260°C for 5 seconds
[1.6 mm (0.063 in.) from body]
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the Absolute Maximum Ratings.
Electrical Characteristics at T
= 25°C
A
Device Test
Symbol Description HLMP- Min. Typ. Max. Units Conditions
I
Luminous Intensity High Efficiency Red
V
1300 1.3 5.0 mcd I
= 10 mA
F
1301 2.1 5.5 1302 3.4 7.0 1385 8.6 11.0
Orange K400 1.3 5.0 K401 2.1 5.5 K402 3.4 7.0
Yellow 1400 1.4 5.0 1401 2.2 6.0 1402 3.6 7.0 1485 5.7 10.0
Green 1503 1.0 5.0 1523 2.6 7.0 1585 4.2 8.5
Emerald Green K600 1.0 4.5
1-135
Loading...