Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 712980-001 December 2012 Edition: 1
Page 2
© Copyright 2012 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation. Intel® is a trademark of Intel Corporation in the United States and other countries.
Page 3
Contents
Technician notes ........................................................................................................................... 4
Warnings, cautions, and notes ...................................................................................................................... 4
Downloading files ........................................................................................................................................ 4
HP contact information .................................................................................................................................. 5
Introduction .................................................................................................................................. 6
Overview .................................................................................................................................................... 6
UTP CAT6/CAT6a cable .............................................................................................................................. 6
LEDs ........................................................................................................................................................... 6
Installing an adapter ..................................................................................................................... 8
Installation overview ..................................................................................................................................... 8
Preventing electrostatic discharge .................................................................................................................. 8
Installing an adapter in a server..................................................................................................................... 9
Installing a low profile bracket ....................................................................................................................... 9
Connecting the network cable ..................................................................................................................... 10
Specifications ............................................................................................................................. 11
UTP cable specifications ............................................................................................................................. 11
General specifications ................................................................................................................................ 11
Compliance ............................................................................................................................................... 11
Power and environmental specifications ....................................................................................................... 12
Regulatory compliance notices ..................................................................................................... 13
Safety and regulatory compliance ................................................................................................................ 13
Warranty information ................................................................................................................................. 13
Turkey RoHS material content declaration ..................................................................................................... 13
Ukraine RoHS material content declaration ................................................................................................... 13
Electrostatic discharge ................................................................................................................. 14
Preventing electrostatic discharge ................................................................................................................ 14
Grounding methods to prevent electrostatic discharge .................................................................................... 14
Acronyms and abbreviations ........................................................................................................ 15
Documentation feedback ............................................................................................................. 16
Contents 3
Page 4
Technician notes
Warnings, cautions, and notes
WARNING: Only authorized technicians trained by HP should attempt to repair this equipment.
All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
WARNING: To reduce the risk of electric shock, personal injury, and damage to the equipment:
Do not attempt to service any parts of the equipment other than those specified in the following
procedure. Any other activities may require that you shut down the server and remove the power cord.
Installation and maintenance of this product must be performed by individuals who are
knowledgeable about the procedures, precautions and hazards associated with the product.
WARNING: To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to cool
before touching.
CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of
clearance at the front and back of the server.
CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper
operation, plug the AC power cord into a properly grounded AC outlet only.
NOTE: Any indications of component replacement or printed wiring board modifications may
void any warranty.
Downloading files
1. Go to the HP website (http://www.hp.com/#Support).
Technician notes 4
Page 5
2.
Select Download drivers and software (and firmware).
3. Type the adapter name in the For product box and then click Go. For example, type HP Ethernet 10Gb
2-port 530T.
4. Download the drivers, firmware, or documentation as needed.
HP contact information
For United States and worldwide contact information, see the Contact HP website (http://www.hp.com/go/assistance).
In the United States:
To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be
recorded or monitored.
If you have purchased a Care Pack (service upgrade), see the Support & Drivers website
(http://www8.hp.com/us/en/support-drivers.html). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care Packs, see the HP website (http://pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html).
Technician notes 5
Page 6
Introduction
Overview
The HP Ethernet 10Gb 2-port 530T Adapter is a dual-port, 10GBase-T adapter that supports Gen8 ML/DL/SL ProLiant servers and uses the Broadcom 57810s Meru-D and BCM84833 PHY chipsets.
For more information about the HP Ethernet 10Gb 2-port 530T Adapter, see the HP website
UTP CAT6/CAT6a cable
(http://www.hp.com/go/proliantnics).
The HP Ethernet 10Gb 2-port 530T adapter can use existing UTP CAT6 (or better) cable to deliver Gigabit Ethernet over copper, according to the IEEE 802.3an specifications. For new installations, CAT6a cable is recommended.
LEDs
For troubleshooting and other information about cabling, see "UTP cable specifications (on page 11)."
The HP Ethernet 10Gb 2-port 530T Adapter has two ports with LEDs for Link (L) and Activity (A) for each port. A standard-height bracket is shown in the following illustration with ports and LEDs.
Item LED Description
1
Link Off = No link to the adapter is established. The adapter is not receiving power or
the cable connection is faulty. Amber = Link to the adapter is established at 10 Gb/s. The adapter is receiving power and the cable connection is good. Green = Link to the adapter is established at 1 Gb/s. The adapter is receiving
Introduction 6
Page 7
Item LED Description
Green = Indicates network activity on the link. The adapter is sending or receiving
power and the cable connection is good.
2
Activity Off = Indicates no network activity on the link.
network data at up to 10 Gb/s.
Introduction 7
Page 8
Installing an adapter
Installation overview
This section describes installation precautions, how to install the adapter, and how to connect the network cable.
WARNING: To reduce the risk of personal injury or damage to the equipment, consult the safety
information and user documentation provided with the server before attempting the installation. Some servers contain high energy circuits, high current circuits, moving parts (such as fan blades), or any combination of these hazards, that may be exposed if covers and access panels are removed while the product is connected to a power source. These products are intended to be serviced only by qualified personnel who have been trained to deal with these hazards. Do not remove enclosures or attempt to bypass any interlocks designed to guard against these hazardous conditions.
WARNING: Installation of this adapter should be performed by individuals who are both
qualified in the servicing of computer equipment, and trained in the hazards associated with products capable of producing hazardous energy levels. This adapter is intended to be installed in Certified (UL or CSA) ITE equipment having instructions for adding and removing user installed components such as PCI, PCI-X, and PCI Express devices. Refer to the equipment instructions to verify that it is suitable for user installed components and that it has the power capacity to support all of the installed components.
NOTE: Before removing the cover of your server, refer to the HP documentation for the proper
methods for installing a PCI Express card and avoiding electric shock hazards.
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or assembly.
Installing an adapter 8
Page 9
Installing an adapter in a server
For additional information on how to safely install a PCI Express card in the server, see the HP ProLiant server documentation.
CAUTION: If the server is not PCI Hot Plug compliant, power it down and disconnect the power
cord from the power outlet before removing the server access panel. Failure to do so may damage
1. Power down the server.
2. Remove the power cord and server access panel.
3. Identify the PCIe expansion slot in which the adapter is to be installed. If a low profile option slot is to
4. Remove the expansion slot cover from the PCI Express slot.
the adapter or server.
WARNING: To reduce the risk of personal injury from a hot component, allow the surface of the
option card to cool before touching it.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
be used, install the low profile bracket onto the adapter.
5. Firmly seat the adapter in the PCI Express slot.
NOTE: For 1U type servers you may need to replace the standard profile bracket with a low
profile bracket. See "Installing a low profile bracket (on page 9)."
6. Install the access panel, and then connect the power cord.
Installing a low profile bracket
You may have to install a low profile bracket to complete the product installation. The low profile bracket replaces the existing standard profile bracket shipped on the product.
To install a low profile bracket:
Installing an adapter 9
Page 10
1.
Using a correctly sized slotted screwdriver, carefully remove the two board lock screws located at the top and bottom of the connector.
2. Remove the standard profile bracket and place the low profile bracket over the connector. Be careful
not to damage the connector or bind the low profile bracket to the connector.
Connecting the network cable
To secure the cable, plug the cable connector into the RJ-45 port. Ensure that the tab on the plug clicks into position indicating that it is properly seated.
For more information, see "UTP cable specifications (on page 11)".
Installing an adapter 10
Page 11
Specifications
UTP cable specifications
The HP Ethernet 10Gb 2-port 530T adapter can use existing UTP CAT6 (or better) cable to deliver Gigabit Ethernet over copper, according to the IEEE 802.3an specifications. For new installations, CAT6a cable is recommended.
Maximum distances for CAT6 cable are 30 meters (98 feet). Maximum distances for CAT6a are 100 meters (328 feet).
To connect to the network, the HP Ethernet 10Gb 2-port 530T uses the following cable for 10GBase-T transmission:
CAT6 UTP or better twisted-pair
22-26 AWG, 100 @ 1 MHz
EIA/TIA 568-B.2-10b
General specifications
Specification Value
Controller Data rate PCI bus Connectors Dimensions (LxW)
Broadcom 57810S (Meru) and 10GBaseT PHY (84833) 10 Gb/s per port, 20 Gb/s combined, full-duplex PCI Express x8 Gen2.1 Two 10GBase-T
16.76 cm x 6.89 cm (6.6 inches x 2.7 inches) without bracket
Compliance
Compliance Standard
IEEE
Safety
IEEE 802.3az (EEE), IEEE802.3, IEEE802.3ap, IEEE802.3xx, IEEE802.2x, IEEE802.3ad, 802.1Qaz, 802.1Qau, 802.1Qbb, 802.1Qbg, 802.1Qbh
UL Mark (US and Canada) EN 60950
Specifications 11
Page 12
Compliance Standard
Other
PCIe 2.1 RoHS 6 of 6 IPv6 CE Microsoft Windows Hardware Quality Labs Server Design Guide version 3.0 SNMP IPv4, TCP and UDP Checksum Offload IPv4/IPv6 TCP, Large Send Offload Receive-Side Scaling Jumbo Frames up to 9000 bytes
Power and environmental specifications
Specification Value
Power
Temperature
Humidity
4 W typical, 9 W maximum 10 W typical, 20 W maximum (with PHY)
Operating—0° to 55° C (32° to 131° F) Non-operating—65° to 85° C (-85° to 185° F)
Operating—10 to 90% relative humidity, non-condensing Non-operating—5 to 95% relative humidity, non-condensing
Specifications 12
Page 13
Regulatory compliance notices
Safety and regulatory compliance
For safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the HP website
Warranty information
(http://www.hp.com/support/Safety-Compliance-EnterpriseProducts).
HP ProLiant and X86 Servers and Options (http://www.hp.com/support/ProLiantServers-Warranties)
HP Enterprise Servers (http://www.hp.com/support/EnterpriseServers-Warranties)
HP Storage Products (http://www.hp.com/support/Storage-Warranties)
HP Networking Products (http://www.hp.com/support/Networking-Warranties)
Turkey RoHS material content declaration
Ukraine RoHS material content declaration
Regulatory compliance notices 13
Page 14
Electrostatic discharge
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic discharge
Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist
straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when
standing on conductive floors or dissipating floor mats.
Use conductive field service tools.
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.
For more information on static electricity or assistance with product installation, contact an authorized reseller.
Electrostatic discharge 14
Page 15
Acronyms and abbreviations
CSA
Canadian Standards Association
IPv4
Internet Protocol version 4
IPv6
Internet Protocol version 6
PCIe
peripheral component interconnect express
PCI-X
peripheral component interconnect extended
PHY
physical layer device
RoHS
Restriction of Hazardous Substances
UDP
User Datagram Protocol
UTP
unshielded twisted pair
Acronyms and abbreviations 15
Page 16
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.
Documentation feedback 16
Loading...