HP A-MSR20 Installation Manual

HP A-MSR20 Router Series
Part number: 5998-1411 Software version: CMW520-R2207P02
Installation Guide
Abstract
This document guides you through installation of HP A Series products, including installing the device, connecting to the network, hardware management, and troubleshooting.
Legal and notice information
© Copyright 2011 Hewlett-Packard Development Company, L.P.
No part of this documentation may be reproduced or transmitted in any form or by any means without prior written consent of Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Contents
Product overview ······························································································································································ 1
A-MSR20-20 panel views ················································································································································ 1 A-MSR20-21 panel views ················································································································································ 2 A-MSR20-40 panel views ················································································································································ 2
Preparing for installation ················································································································································· 4
Safety recommendations ·················································································································································· 4
Installation site requirements ··································································································································· 4 Cooling ······································································································································································ 5 Lightning protection ·················································································································································· 5
Rack-mounting requirements···································································································································· 6 Installation tools ································································································································································· 6 Pre-installation checklist ···················································································································································· 7
Installing the router ·························································································································································· 9
Installation prerequisites ··················································································································································· 9 Installation flowchart ······················································································································································ 10 Installing the router ························································································································································· 11
Installing the router on a workbench ··················································································································· 11
Mounting the router in a 19-inch rack ················································································································ 11
Grounding the router ············································································································································ 13
Installing interface modules ·································································································································· 15 Connecting interface and power cables ····················································································································· 17
Connecting an Ethernet cable ······························································································································ 17
Connecting the console cable and setting terminal parameters ······································································ 17
Connecting the AC power cord ··························································································································· 21 Verifying the installation ················································································································································ 21 Starting up and configuring the router ························································································································ 21
Powering on the router ········································································································································· 21
Configuring basic settings for the router ············································································································· 23
Installing and upgrading internal modules and FRUs ································································································ 24
Opening and removing the chassis cover ··················································································································· 24 Locating internal modules·············································································································································· 26 Installing and removing a VPM module······················································································································· 29
Installing a VPM module ······································································································································· 29
Removing a VPM module ····································································································································· 30 Installing and removing a VCPM or ESM module ······································································································ 30
Installing a VCPM or ESM module ······················································································································ 31
Removing a VCPM or ESM module ···················································································································· 32 Installing and removing a CF card······························································································································· 32
Installing a CF card ··············································································································································· 32
Removing a CF card ············································································································································· 33
Troubleshooting ······························································································································································ 34
Power supply failure ······················································································································································ 34 Fan failure ······································································································································································· 34 Configuration system problems ···································································································································· 34
No terminal display ·············································································································································· 35
Garbled terminal display ····································································································································· 35
No response from the serial port ························································································································· 35
iii
Password loss ································································································································································· 35
User password loss ··············································································································································· 35
Super password loss ············································································································································· 36 Interface module, cable, and connection failure ········································································································ 37
Support and other resources ········································································································································ 38
Contacting HP ································································································································································ 38
Subscription service ·············································································································································· 38 Related information ························································································································································ 38
Documents ······························································································································································ 38
Websites ································································································································································ 38 Conventions ···································································································································································· 39
Appendix A Technical specifications··························································································································· 41
Appendix B LEDs ···························································································································································· 42
A-MSR20-20 LEDs ·························································································································································· 42 A-MSR20-21LEDs ··························································································································································· 43 A-MSR20-40 LEDs ·························································································································································· 44
Appendix C Slot arrangement and interface numbering ·························································································· 46
Slot arrangement ···························································································································································· 46 Interface numbering ······················································································································································· 46
Index ················································································································································································ 48
iv
Product overview
J#
Type
JF283A
A-MSR20-20
JD663B
A-MSR20-21
JF228A
A-MSR20-40
123
(1) PWR LED
(2) SYS LED
(3) ESM LED
1 2
3456789
10
(1) SIC slot 2
(2) SIC slot 1
(3) CF card slot
(4) USB port
(5) AUX port
(6) Console port
(7) Ethernet WAN ports (ETH0 and ETH1)
(8) Power switch
(9) Power receptacle (10) Grounding screw
This chapter discusses the chassis panels of the HP A-MSR20 Router Series models listed in Table 1. The chassis panel views shown may differ slightly from the actual panels.
Table 1 HP A-MSR20 Router Series models
A-MSR20-20 panel views
Figure 1 A-MSR20-20 front panel
Figure 2 A-MSR20-20 rear panel
1
A-MSR20-21 panel views
123
(1) PWR LED
(2) SYS LED
(3) ESM LED
1 2
3456789
1011
(1) SIC slot 2
(2) SIC slot 1
(3) CF card slot
(4) USB port
(5) AUX port
(6) Console port
(7) Ethernet WAN ports (ETH0 and ETH1)
(8) Ethernet LAN ports (ETH2 to ETH9)
(9) Power switch (10) Power receptacle
(11) Grounding screw
1 2 3
456
(1) Console port
(2) Power switch
(3) Power receptacle
(4) AUX port
(5) USB port
(6) CF card slot
Figure 3 A-MSR20-21 front panel
Figure 4 A-MSR20-21 rear panel
A-MSR20-40 panel views
Figure 5 A-MSR20-40 front panel
2
Figure 6 A-MSR20-40 rear panel
1 2
3456
(1) SIC slot 4
(2) SIC slot 3
(3) Ethernet WAN ports (ETH0 and ETH1)
(4) SIC slot 1
(5) SIC slot 2
(6) Grounding screw
3
Preparing for installation
WARNING!
Before installation and operation, read all of the safety instructions in the
Compliance and Safety
Guide
supplied with your router.
Temperature
Relative humidity
0°C to 40°C (32°F to 104°F)
5% to 90%
Substance
Concentration limit (particles/m3)
Dust particles
≤ 3 x 104
(No visible dust on desk in three days)
NOTE:
Dust particle diameter ≥ 5 µm
This chapter discusses safety, site, and rack-mounting requirements, as well as the tools and accessories needed for installation.
Safety recommendations
General safety recommendations follow:
Turn off all power and remove all power cables before opening the chassis. Unplug all power and external cables before moving the chassis. Before installation, locate the emergency power switch so that you can shut off power immediately if
necessary.
Always wear an ESD-preventive wrist strap when installing the device. Do not stare into an open optical interface. The light can cause permanent eye damage. Use a good grounding system. This is essential for reliable operation. Confirm that the resistance between the chassis and the ground is less than 1 ohm.
Installation site requirements
This section provides information about temperature and humidity, cleanness, and air quality requirements.
Table 2 Temperature and humidity requirements
Table 3 Dust concentration limit in the equipment room
4
Table 4 Harmful gas concentration limits in the equipment room
Gas
Maximum concentration (mg/m3)
SO
2
0.2
H2S
0.06
NH
3
0.05
Cl
2
0.01
Cooling
Air flows through the A-MSR20 from left to right, as shown in Figure 7.
Figure 7 A-MSR20 ventilation
To prevent overheating:
Provide adequate clearance for air flow.
Provide at least 10 cm [3.94 in] ventilation space around the router's air intake and outlet vents.
For heat dissipation and device maintenance, the front and rear of the rack should be at least
0.8 m (2.62 ft) away from walls or other devices.
The equipment room ceiling height should be no less than 3 m (9.84 ft).
Make sure the site has an adequate cooling system.
Lightning protection
To protect the router from lightning:
Make sure the grounding cable of the chassis is grounded properly. Make sure the grounding terminal of the AC power receptacle is grounded properly. Install a lightning arrester at the input end of the power supply. Install a lightning arrester at the input end of outdoor signal lines (for example, E1/T1 line) to which
the router’s interface modules are connected.
5
Rack-mounting requirements
Before rack-mounting a switch, make sure the rack meets the following requirements:
Size. The rack must be appropriately sized to hold the switch. Ventilation. HP recommends that you mount a switch in an open rack. If you mount a switch in a
closed rack, provide an adequate heat dissipation system. With either type of rack, there must be enough space around the switch's left and right panels for unimpeded airflow and heat dissipation.
Sturdy support. The rack must provide steady, secure support for the switch and accessories.
Installation tools
Accessories supplied with the router
Power cord Console cable Grounding cable Mounting brackets
User-supplied tools and equipment
Phillips screwdriver P1 – 100 mm, P2 – 150 mm, and P3 – 250 mm Flat-bladed screwdriver P4 – 75 mm Screws with different specifications Meters and equipment such as HUB, terminal, and multimeter ESD-preventive gear, including gloves or wrist strap, mat or other work surface, and antistatic bags
6
Item
Requirements
Yes No
Installation site
Ventilation
There is a minimum clearance of 10 cm (3.9 in) around
the router chassis intake and exhaust vents for heat dissipation.
The installation site ventilation system is adequate.
Temperature
0°C to 40°C (32°F to 104°F)
Relative humidity
5% to 90% (noncondensing)
Cleanness
Dust concentration ≤ 3 × 104 particles/m3
ESD prevention
The equipment and floor are properly grounded. The equipment room is dust-controlled. Humidity and temperature are maintained at proper
levels.
Wear an ESD-preventive wrist strap when inspecting or
handling a circuit board.
Place any removed memory module, CF card, or
interface module face-up on an antistatic workbench or in an antistatic bag.
Touch only the edges, not any electronic components,
when inspecting or handling a memory module, CF card, or interface module.
EMI prevention
Take measures to protect the power system from the
power grid system.
Keep the protection ground of the router as far away
from the grounding device or lightning protection grounding device as possible.
Keep the router far away from radio transmitters, radar,
and high-frequency or high-voltage devices.
Use electromagnetic shielding when necessary.
Lightning protection
The grounding cable of the chassis is grounded
properly.
The grounding terminal of the AC power receptacle is
grounded properly.
A port lightning arrester is installed. (Optional) A power lightning arrester is installed. (Optional) A signal lightning arrester is installed at the input end
of an external signal cable. (Optional)
Electricity safety
Install a UPS. In case of emergency during operation, switch off the
external power switch.
Workbench
The workbench is stable. The workbench is grounded properly.
Pre-installation checklist
Table 5 Pre-installation checklist
7
Item
Requirements
Yes No
Rack mounting
Install the router in an open rack if possible. If you
install the router in a closed cabinet, make sure that the cabinet is equipped with a good ventilation system.
The rack is sturdy enough to support the weight of the
router and accessories.
The size of the cabinet is appropriate for the router. The front and rear of the cabinet are at least 0.8 m
(31.50 in) away from walls or other devices.
Safety precautions
The router is far away from any sources of heat or moisture. The emergency power switch in the equipment room is identified and
accessible.
Tools
Installation accessories supplied with the router are ready. User-supplied tools are ready.
Reference
Documents shipped with the router are available. Online documents are available.
8
WARNING!
To avoid injury, do not touch bare wires, terminals, or parts with high-voltage hazard signs.
NOTE:
The barcode on the router chassis contains important product information that you must provide to HP Support
before returning a faulty router for service.
The HP tamper-proof label attached to a mounting screw on the router chassis must be kept intact. Before
opening the chassis cover, contact HP Support for authorization; if you do not, you take full responsibility for all operation and maintenance failures.
Installing the router
This chapter provides instructions for installing the router on a workbench or mounting it in a 19-inch rack.
Installation prerequisites
You have read "Preparing for installation" carefully. All requirements in "Preparing for installation" are met.
9
Start
Connect the PGND cable
Install interface modules
Verify the installation
Connect interface cables
Power on the router
Operating properly? Power off the router
Troubleshoot the router
End
Yes
No
Connect the router to a
console terminal
Connect the power cable
Install the router to a
specified position?
Check the workbench Install a 19-inch rack
Install the router to a rack
Install the router to a
workbench
Installation flowchart
Figure 8 shows two ways to install your router:
Install the router on a workbench. Install the router in a 19-inch rack.
Figure 8 A-MSR20 router installation flowchart
10
CAUTION
Mounting brackets can support only the weight of the router. To avoid damaging the router, do not place any objects on it.
1 2
43
Installing the router
When installing the router:
Reserve a space of 10 cm (3.9 in) around the router for heat dissipation. Do not place heavy objects on the router.
Installing the router on a workbench
To install the router on a workbench:
1. Make sure the workbench is clean, stable and properly grounded.
2. Place the router upside down on the workbench and attach the rubber feet to the four round holes
in the chassis bottom.
3. Place the router upright on the workbench.
Mounting the router in a 19-inch rack
A-MSR20-20/A-MSR20-21 router
Figure 9 Rack-mounting the A-MSR20-20/A-MSR20-21 router
To mount the router in a 19-inch rack, as shown in Figure 9:
1. Determine where to attach the cage nuts to match the mounting bracket holes.
2. Attach the cage nuts to the rack posts.
3. Attach the front mounting brackets, shown in Figure 10, to the sides of the router.
4. Mount the router in the rack horizontally by fastening the mounting brackets to the rack with
rustproof panhead screws that meet installation requirements.
11
1 2
(1) Left front mounting bracket
(2) Right front mounting bracket
CAUTION
Mounting brackets can support only the weight of the router. To avoid damaging the router, do not place any objects on it.
21
3 4
65
Figure 10 A-MSR20-20/A-MSR20-21 mounting brackets
A-MSR20-40 router
Figure 11 Rack-mounting the A-MSR20-40 router
To install the router in a 19-inch rack, as shown in Figure 11:
1. Attach the rear mounting brackets, shown in Figure 12, to the rack. a. Determine where to attach the cage nuts to match the mounting bracket holes. b. Attach the cage nuts to the rack posts. c. Attach the rear mounting brackets to the rack.
2. Attach the front mounting brackets, shown in Figure 12, to the sides of the router.
12
1 2 3 4
(1) Left front mounting bracket
(2) Right front mounting bracket
(3) Left rear mounting bracket
(4) Right rear mounting bracket
WARNING!
Connecting the router grounding cable correctly is crucial for protecting the router from lightning and EMI.
3. Screw two weight-bearing screws into the appropriate holes, one on the left side and one on the
right side of the router. These screws will rest on the top edges of the rear mounting brackets.
4. Position the router so that the weight-bearing screws fit securely over the top edges of the rear
mounting brackets.
5. Secure the router fastening the front mounting brackets to the rack with rustproof panhead screws
that meet installation requirements.
Figure 12 A-MSR20-40 front and rear mounting brackets
Grounding the router
The grounding resistance should be less than 5 ohms.
If the router is mounted in a 19-inch standard rack, the rack must be properly grounded.
You can ground the router in one of the following ways, depending on the grounding conditions at the installation site:
Ground the router to a properly grounded grounding strip. Ground the router to a grounding conductor buried in the earth.
Grounding the router to a grounding strip
To connect the grounding cable, as shown in Figure 13:
1. Remove the grounding screw from the rear panel of the router chassis.
2. Put the OT terminal of the supplied grounding cable on the grounding screw.
3. Use a screwdriver to fasten the grounding screw, with the grounding cable OT terminal attached,
to the grounding screw hole.
13