HP (Hewlett-Packard) A3700-90905 User Manual

36-Gigabyte Disk Drive Module Installation
When installing a 36-Gigabyte disk drive module into an HP SureStore E Disk Array 12H, the controller firmware of the disk array must be a t revision HP54 or higher . The use of 36-Gigabyte disk drives on controller firmware revision previous to HP54 is not supported. If a 36-Gigabyte disk drive is manually included under older controller firmware, it will be treated as if its physical capacity is about 24 Gigabytes.
You can find the controller firmware revision number either manually via the front panel or by using the ARMServer utilities.
KEY CANCEL CANCEL “Ready”
MENU “Language” – “View Settings” ENTER “System State: Ready” + “Primary Cntrl: _” + “SCSI ID x: ___” + “SCSI ID y: ___” + “Firmware: HP__”
To determine the version of firmware using the ARMServer: You can get the controller firmware revision using the ARMServer utilities. The command syntax follows:
arraydsp -c <array-id>
When using the ARMServer utilities, the <array-id> field is used to identify the disk array. The <array-id> field ca n contain th e d isk arra y ser ial number or the raw device file name of any LUN on
the array. To download firmware, refer to the following:
http://SNServer.mayfield.hp.com/
http://SNServer.mayfield.hp.com/products/A3700A/
DISPLAY
CAUTION! When upgrading to HP54 (or higher) for the purpose of using 36­Gigabyte disk drives, it is important that the controller firmware be upgraded before adding the 36-G igabyte disk drives, as any data written on those disk drives under any controller firmware previous to HP54 will be lost!
36-Gigabyte Disk Drive Module Installation Requirement
Customer part number: A3700-90905 Printed in U.S.A. May 1999 Edition 2 E0599
Part Number
' $(&#%'
*A3700-96008*