![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg1.png)
HP 3000 Series 9X8LX/RX PA-RISC Computer System
Installation and Configuration Guide
Series 9X8LX/RX Family
rli~
~~ PACKARD
HP Part No. A2051·90006
Printed in U.S.A. 1993
HEWLETT
First Edition
E1093
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg2.png)
Notice
Hewlett-Packard makes no warranty of any kind with regard to this material, including,
but not limited to, the implied warranties of merchantability and fitness for a particular
purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of this material.
Hewlett-Packard assumes no responsibility for the use or reliability of its software on
equipment that is not furnished by Hewlett-Packard.
This document contains proprietary information which is protected by copyright. All rights
are reserved. No part of this document may be photographed, reproduced, or translated to
another language without prior written consent of Hewlett-Packard Company.
The information contained in this document is subject to change without notice.
@
Copyright Hewlett-Packard Company, 1993. All rights reserved.
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg3.png)
Printing History
New editions are complete revisions of the manual. Update packages, which are issued
between editions, contain additional and replacement pages to be merged into the manual by
the customer. The dates on the title page change only when a new edition or a new update
is published. No information is incorporated into a reprinting unless it appears as a prior
update; the edition does not change when an update is incorporated.
Many product updates and fixes do not require manual changes and, conversely, manual
corrections may be done without accompanying product changes. Therefore, do not expect a
one-to-one correspondence between product updates and manual updates.
First Edition October 1993
List of Effective Pages
The List of Effective Pages gives the date of the current edition and of any pages changed
in updates to that edition. Within the manual, any page changed since the last edition
is indicated by printing the date the changes were made on the bottom of the page. No
information is incorporated into a reprinting unless it appears as a prior update.
All October 1993
iii
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg4.png)
Safety and Regulatory Information
For your protection this product has been tested to various national and international
regulations and standards. The scope of this regulatory testing includes electrical/mechanical
safety, radio frequency interference, ergonomics, acoustics, and hazardous materials. Where
required, approvals obtained from third-party test agencies are shown on the product label. In
addition, various regulatory bodies require someinformation under the followingheadings.
FCC Statement (USA only)
The United States Federal Communications Commission (in SubpartJ,of Part 15, Docket
20780) has specified that the followingnotice be brought to the attention of the users of this
product:
Warning
This equipment generates, uses, and can radiate radio frequency energy and if
not installed and used in accordance with the instructions manual, may cause
interference to radio communications. It has been tested for compliance with
the limits of ClassAcomputing devices pursuant to Subpart J of Part
FCC Rules, which are deSigned to provide reasonable protection against such
interference.
Operation of this equipment in a residential area is likely to cause interference
in which case the user at his own expense will be required to take whatever
measures may be required to correct the interference.
Japanese Radio Frequency Interference
i:.
0)~i1i!
C'
ffii
I~!iB~
~~~ (VCCI)
.vt..,
3 /
§tf~~~
-c.
Ii.
m-f~IH~ffl~i?1-CFmI*Jt!r~K
-Z:-.0).il[.1&:~~~J.7:L1:.
~·§-it.]-c
1iJ;ifKJljiSl-C:Jol)iTv
~"8:tt!!~
Ie:
~{§
't
t:
lIf'J;~
(;:I:
-t-
O)~ng
i-4;t ~
i:.
L
C
i;.~'
-l,
t:.:ffl~~:~~.~
t:.ttB~C'~ffl
t.J~
it>
I)
't
To
-C{fJf~
T ~
2'
n
{,«
~·ffl~·~·~) .
~:~·ilR:~~:§±:1J!J1jIJ:
C,
'7:;;t, T
i-
15
of
t:
y
~ 1&~
iv
B~• Ie:
itE ..,-cIf.
L ~\
1&
I)
1&~\i-l-cF
Japanese Radio Frequency Notice
tt
~'o
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg5.png)
Finland (only)
LASERTURVALLISUUS
LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT
HP 3000 Series 9x8LX/RX -tietokoneisiin voidaan asentaa Iisavarusteena muistilaitteeksi
laitteensisainen CD-ROM-levyasema,joka on laserlaite.
Kyseinen CD-ROM-levyasema on kayttajan kannalta turvallinen luokan llaserlaite.
Normaalissa kaytossa levyaseman suojakotelo estaa lasersateen paasyn laitteen ulkopuolelle.
CD-ROM-levyaseman on tyyppihyvaksynyt Suomessa laserturvallisuuden osalta
Tyoministerion tyosuojeluosasto. Laitteen turvallisuusluokka on maaritetty valtioneuvoston
paatoksen N:o 472/1985 ja standardin SFS-EN 60825 (1992) mukaisesti.
Tiedot CD-ROM-levyasemassa kaytettavan laserdiodin sateilyominaisuuksista:
Aallonpituus 790 nm
Teho 1,1 pW
Luokan 1 laser
Acoustics (Germany only)
Laermangabe (SchalldruckpegelLpA) gemessen an Arbitplatzbei norrnalen Betrieb nach DIN
45635,teil 19:
Acoustic noise (A-weight sound pressure level LpA) measured at operator's position, normal
operation, to 1807779:
HP
300 9X8LX/RX:
59dB bis (up to) 37°C, 62dB ueber (above) 37°C
v
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg6.png)
Safety Considerations
This product and related documentation must be reviewed for familiarization with safety
markings and instructions before operation. The following figure shows some of the safety
symbols used on the product to indicate various safety considerations.
Warning
Caution
I
The WARNING sign denotes a hazard. It calls attention to a procedure,
practice, of the like, which if not done correctly or adhered to, could result in
injury. Do not proceed beyond a WARNING sign until the indicated conditions
are fully understood and met.
The CAUTION sign denotes a hazard. It calls attention to an operating
procedure, practice, of the like, which if not done correctly or adhered to,
could damage or destroy part or all of the product. Do not proceed beyond a
CAUTION sign until the indicated conditions are fully understood and met.
Preface
This manual is intended for use by trained and experienced Hewlett-Packard field maintenance
personnel. This edition of the Installation and Configuration Guide contains technical
information about the HP 3000 Series 9X8LXjRX Family of computers listed in the table
below.
Computer Type
Description"
HP 3000 928LX
HP 3000 928RX
HP 3000 968LX
HP 3000 968RX
Other Documents Referenced in this Guide:
Part Number Title
5958-5859
5958-2370
50779-90012
2 slot Ij0chassis with a 48MHz CPU
4 slot 110 chassis with a 48MHz CPU
2 slot 110 chassis with a 64MHz CPU
4
slot 110 chassis with a 64MHz CPU
HP 3000 and HP 9000 CE HandbookA1707-90016
Computer Products Site Preparation Resources Guide
HP CEO Site Preparation Handbook
HP Predictive Support User's Guide
vi
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg7.png)
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacture's Name:
Hewlett-Packard
8000 Foothills Blvd.
Roseville CA. 95747, U.S.A.
declares, that the product:
Product Name: PA-RISC Computer System
Model Number(s): HP3000908LX
HP3000 918LX/RX
HP3000 928LX/RX
HP3000 968LX/RX
HP3000 978RX
HP9000 E25 (806)
HP9000 E35 (816)
HP9000 E45 (826)
Conform to the following Product Specifications:
Safety:
EMC:
IEC950: 1986+Al+A2/EN 60950: 1988+Al+A2
CISPR-22: 1985/EN55022:1988-Class A
IEC801-2: 1991/prEN55024-2: 1992 -3kV CD, 8kV AD
IEC801-3: 1991/prEN55024-3: 1991 3V/m
IEC801-4: 1988/prEN55024-4: 1992 0.5kV Signal Lines,
1KV Power Lines
Supplementary Information:
The product herewith complies with the requirements of the Low VOltage
Directive 73/23/EEC and the EKC Directives 89/336/EEC.
RoseVille~~
e. -~
Ed Heinsen, NCMOQality Manager
Quality Department NCMO, Roseville, California, U.s.A.
European Contact: Your local Hewlett-Packard sat.esand service
office or Hewlett-Packard GmbH, department ZQ/Standards Europe,
Herrenberger Strafie 130, D-71034 Boblingen FAX: +49-7031-14-3143
vii
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg8.png)
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg9.png)
Contents
1. About This Manual
2. Site Considerations
Site Preparation Considerations .
Physical Considerations .
Electrical Considerations. . .
Specifications . . . . . . . .
Hewlett-Packard Responsibilities
Third Party Service . .
Customer Responsibilities
Local Codes . . . . .
Data Communications Equipment .
3. Receiving The System
Unpacking and Inspection . . . . . . . . .
Unpack the HP 3000 9X8LX/RX Computer
In Case of Damage
Physical Inventory
Manuals.
Equipment .
Computer .
Claims Procedures
Repacking ....
Storage Requirements
2-1
2-1
2-2
2-2
2-5
2-5
2-7
2-7
2-7
3-1
3-1
3-4
3-4
3-4
3-4
3-4
3-4
3-5
3-5
4. Installation
Installation Procedures
SPU Installation
System Console Installation
Peripheral Equipment
DTC Installation ..
PowerTrust UPS
External Disk Cabinet
Installation Completion
4-1
4-1
4-3
4-4
4-4
4-4
4-5
4-5
Contents-1
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bga.png)
5. Starting the Computer System
Turning On the Computer System
Initial Power On . . . . . . .
Power On Selftest and PDC Displays
Installation Verification . . . .
Verifier global status messages
Verifier log file . . . . . . .
A. Remote Support Modem Configuration
Quick Reference .
HP Support Link (HP50759A) . . .
Hayes Smartmodem 2400 .....
Black Box V.32 Plus (Version 2.01.01)
Multitech MT224EH7
HP 37212B .
Modem Cable Pin-out . . . . . . .
Multifunction I/O PCA Modem Line Behavior
CCITT Mode AP protocol 0 . .
Bell Mode AP protocol 1 .
CCITT _BIS Mode AP protocol 2 . . .
Modem Settings (HP Predictive Support)
5-1
5-1
5-2
5-4
5-4
5-5
A-2
A-2
A-4
A-5
A-6
A-7
A-8
A-9
A-9
A-9
A-lO
A-I0
Contents-2
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bgb.png)
Figures
3-1. Removing Loose Parts
3-2. Positioning the Shipping Box
3-3. Raising the Flap . . . . .
3-4. Removing the Computer from the Box .
Tables
2-1. Environmental Specifications . . . . . . . . . .
2-2. 2-Slot and 4-slot Chassis Power Specifications
2-3. 2-Slot and 4-Slot Chassis DC Power Specifications
2-4. Electromagnetic Susceptibility Specifications . .
2-5. 2-S1otand 4-Slot Chassis Physical Specifications
2-6. Technical Tasks/Personnel . . . . . . . . . .
4-1. A2941A Line Cord Options .
A-I. Settings for Remote Support Modem (Quick Reference)
A-2. 8-Position DIP Switch Option Settings (Set S)
A-3. 4-Position DIP Switch Option Settings (Set X)
A-4. Switch Option Settings ....
A-5. HP 37212B Switch Configuration . . . . . .
A-6. 92219QCable Pin-out . . .
A-7. Predictive Support Modems and Switch Settings
3-2
3-2
3-3
3-3
2-2
2-3
3
2-4
2-4
2-4
2-6
4-3
A-2
A-3
A-3
A-4
A-8
A-9
A-ll
Contents-3
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bgc.png)
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bgd.png)
About This Manual
1
This manual contains the installation instructions for the HP 3000 Series
Computer Systems.
This manual also contains information for installing the Distributed Terminal Subsystem and
for configuring modems for remote support. This manual does not include instructions for
installing networks.
This manual is organized as follows:
Chapter 1 About This Manual. Introduces the manual and describes its organization.
Chapter 2 Site Considerations. This chapter defines HP organizations and lists site
preparation responsibilities.
Chapter
instructions for unpacking the system, and putting it into position.
Chapter 4 Installation. Contains installation procedures and configuration information.
Chapter 5 Starting the Computer System. Provides instructions for turning on the
equipment, booting MPEjiX, and running the verification program.
Appendix A Support Link Modem Configuration. Provides configuration information on a
number of modems that can be used for the support link modem.
3
Receiving The System. This chapter provides information on receiving the system,
9X8jLXjRX
Family
About This Manual 1-1
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bge.png)
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bgf.png)
2
Site Considerations
The HP 3000 9X8LX/RX family of computers are office environment computer systems that
do not require special environmental controls. For this reason, no specific site preparation is
required before the system is installed. Even though the computer does not require any site
preparation, there are some site considerations and responsibilities that need to be addressed.
This chapter provides the environmental and electrical specifications for the HP 3000
9X8LX/RX systems. These specifications are provided to ensure the installation site is within
the limits for the system. This chapter also lists the HP organizations and services available
for site preparation for the HP 3000 9X8LX/RX family computers. It also lists and describes
the responsibilities of the customer.
Site Preparation Considerations
The HP 3000 Series 9X8LX/RX computers are primarily designed to be used in commercial
office environments. Except for verifying the environment and AC power, very little site
preparation is required. When the computer is configured into a larger system employing
numerous peripherals and mass storage devices, you should study and become more familiar
with the contents of this chapter.
The CE or Site Preparation Specialist provides peripheral equipment power and
environmental specifications contained in the
3000 and HP 9000 CE Handbook.
It is the customers responsibility to ensure that the facility conditions are maintained in
accordance with the information and specifications contained in this chapter.
This allows Hewlett-Packard to provide support services in accordance with the
Support Services Agreement.
Physical Considerations
Since the HP 3000 9X8LX/RX is a small physical package (refer to physical specs Table 2-5 it
can be located next to a desk or placed in a dedicated computer room. Allow room for cables
and access to the front and rear of the computer cabinet.
Be sure to allow for the peripheral equipment that comes with a computer system, such as
peripheral cabinets, PowerTrust UPS, terminals, printers and other supporting equipment.
Also allow for computer materials storage.
HP CEO Site Preparation Handbook
and the
Customer
HP
Site Considerations 2-1
![](/html/7c/7cdf/7cdfff6db4b5ebe48bed03cd5948d9234210274ef8df373eba6874002e10956b/bg10.png)
Electrical Considerations
Be sure the final installation site has enough AC outlets to support the computer and the
peripherals located close to
breaker. Be very sure the AC power available meets the electrical specifications. Refer to
Table 2-2 for the exact electrical specifications.
Specifications
Description Specification
Operating Temperature 5°C to 40°C (41°F to 104°F)
Non-operating Temperature -40°C to 65°C (-40°F to 149°F)
Maximum Rate of Temperature Change
High Speed Fan (Activated) 30°C to 38°C (86°F to 100.4°F)
Overtemp Warning
Overtemp Hardware Shutdown
Operating Humidity
Non-operating Humidity 5% to 80% RH, non-condensing, less than 30% RH/hr
Operating Altitude
Nonoperating Altitude
Heat Dissipation (max load)
Operating Vibration (random) 0.0001 g2/Hz, 5 to 350 Hz
Non-operating Vibration (sine)
Shock (nonoperating) Edge drop from 2.5 in. above floor
Sound Power
it.
Be sure the outlets are grounded and are protected by a circuit
Table 2·1. Environmental Specifications
(without internal DDS-format drive)
-40°C to 45°C (-40°F to 113°F) (with internal
DDS-format drive - tape media limit)
20°C (36°F)/hour (without tape
media)
lOoC (18°F)/hour (with tape media)
40°C to 48°C (104°F to 118.4°F)
Overtemp Warning +2°C (~3°F)
20% to 80% RH max wet bulb=26°C, non-condensing
rate of change
°
to 3048 meters (10,000 ft)
°
to 4573.2 meters (15,000 ft)
1300 BTU/hr
-6dB/Octave, 350-500 Hz
0.00005 g2/Hz, 500 Hz
(~ 0.21 G
0.5g (peak), 5 to 500 Hz
rms
)
< 37°C=< 45 dB(A) sound pressure at operator's position.
< 5.5 bels(A) sound pressure
> 37°C=< 50 dB(A) sound pressure at operator's position.
< 6.0 bels(A) sound pressure
2-2 Site Considerations