HP 275 User Manual

QuickSpecs

Overview

42U Rack with HP ProLiant BL25p System Installed
42U Rack with HP ProLiant BL25p System Installed
42U Rack with HP ProLiant BL25p System Installed42U Rack with HP ProLiant BL25p System Installed
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
1.
BL p-Class interconnects (2) in HP BladeSystem p-Class server blade enclosure (interconnect switch shown)
2.
HP ProLiant BL25p server blades (8) in HP BladeSystem p-Class server blade enclosure
3.
HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6)
What's New
What's New
What's NewWhat's New
Models 275 (2.2GHz), 270 (2.0GHz) and 265 (1.8GHz)
1MB L2 cache per core New HP BladeSystem p-Class 1U Power Enclosure Up to two 2.6GHz AMD Opteron Processors with 1M L2 cache Up to 16GB ECC PC3200 DDR (8 DIMM slots) Integrated Smart Array 6i Plus with optional BBWC
DA - 12160 North America — Version 7 — June 27, 2005
Page 1
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
At A Glance
At A Glance
At A GlanceAt A Glance
Performance dual processor server blade designed with enterprise availability HP ProLiant BL25p server blade includes: AMD Opteron 200 series single and dual-core processors (dual capability)
Models 275 (2.2GHz), 270 (2.0GHz), 265 (1.8GHz), 252 (2.6GHz) and 250 (2.4GHz) HP ProLiant BL25p Dual Port Fibre Channel Adapter (2-Gb) option for SAN connectivity AMD 8131 and 8111 Chipsets 1024-MB or 2048-MB PC3200 Registered ECC 400MHz DDR memory, (2 x 1 Interleaved Memory), expandable to 16 GB Five total network adapters:
Four PCI-X Gigabit Server NICs (embedded) with WOL and PXE (two single-port NC7781 and one dual-port NC7782)
Plus one additional 10/100 NIC dedicated to iLO Management Smart Array 6i (integrated on system board Controller with optional battery-backed write cache) Wide Ultra320 SCSI Drive Cage standard supports up to two 1" Wide Ultra320 hot plug hard drives Integrated Lights-Out (iLO) Advanced Management (ASIC on motherboard) Plugs vertically into 6U enclosure, 8 BL25p server blades per enclosure Cisco Gigabit Ethernet Switch Module (CGESM) option for Gigabit Ethernet network adapter consolidation. Integrated Access Tool for blade management and enhanced server blade documentation including Best Practices and Common Procedures guides HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Server Blade Enclosure:HP BladeSystem p-Class Server Blade Enclosure:
Server blades and interconnects blind mate into server blade enclosures for network connection and power
Server blade enclosure is 6U and holds up to 8 HP ProLiant BL25p server blades and 2 interconnects
Types of interconnects available: GbE Interconnect Switches, GbE2 and CGESM Interconnect Switches with optional
Fibre Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Enclosures:HP BladeSystem p-Class Power Enclosures:
Use BL p-Class sizing tool to determine power based on your configuration
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
BL p-Class power enclosure provides shared, external, redundant power
Choose the HP BladeSystem p-Class 3U power enclosure or the HP BladeSystem p-Class 1U power enclosure
Choose single-phase or three-phase power
HP BladeSystem power enclosures with power supplies are not needed if using facility -48VDC ± 10%, in this case
purchase facility DC option kit HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
Distributes power from the power enclosure to the server blade enclosures
Four power distribution choices:
BL p-Class scalable bus bar
BL p-Class mini bus bar
BL p-Class power bus box
Dual power input kit for mini bus bar (required for support of two power enclosures) HP ProLiant BL25p server blade, and p-Class server blade enclosure, interconnects and power enclosure protected by a limited three year warranty with optional service uplifts available
NOTE:
NOTE:
NOTE: NOTE:
Power requirements for a HP BladeSystem p-Class-: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 2
QuickSpecs
Overview
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
++++
HP BladeSystem p-Class Server Blade Enclosure
HP BladeSystem p-Class Server Blade Enclosure
HP BladeSystem p-Class Server Blade EnclosureHP BladeSystem p-Class Server Blade Enclosure
++++
DA - 12160 North America — Version 7 — June 27, 2005
Page 3
QuickSpecs
Overview
OR
OR
OROR
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Patch Panel (shown) or
Patch Panel 2
BL p-Class Interconnects
BL p-Class Interconnects
BL p-Class InterconnectsBL p-Class Interconnects
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or
CGESM Interconnect Switch (fiber or copper-based)
++++
BL p-Class power enclosures and power supplies
BL p-Class power enclosures and power supplies
BL p-Class power enclosures and power suppliesBL p-Class power enclosures and power supplies
OR
OR
OROR
HP BladeSystem p-Class 1U power enclosure and power supplies
HP BladeSystem p-Class 1U power enclosure and power supplies
HP BladeSystem p-Class 1U power enclosure and power suppliesHP BladeSystem p-Class 1U power enclosure and power supplies
OR
OR
OROR
Facility DC
Facility DC
Facility DCFacility DC
DA - 12160 North America — Version 7 — June 27, 2005
Page 4
QuickSpecs
Overview
OR
OR OR
OROR
OR
OROR
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Scalable bus bar
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
Configuration Steps
Configuration Steps
Configuration StepsConfiguration Steps
For a complete configuration of the HP ProLiant BL25p server blade, do the following:
1.
Select desired model, configuration and quantity of HP ProLiant BL25p server blades.
PLUS
PLUS
PLUSPLUS
2.
Decide how many HP BladeSystem p-Class Server Blade Enclosures to purchase (each enclosure can hold up to 8 HP ProLiant BL25p server blades):
Mini bus bar
Bus boxes
Dual power input kit for mini bus bar
HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack licenses (281404-B22) Or HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack trial (243564-B22) Or HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 HP BladeSystem Management Suite licenses (380625-B22) - includes: a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM)
NOTE:
NOTE:
NOTE:NOTE: server blade model is selected. NOTE:
NOTE:
NOTE:NOTE:
Or
HP BladeSystem p-Class Enhanced Server Blade enclosures may be required depending on which HP ProLiant BL25p
The HP BL25p server blade does not currently support PMP. Future support is planned.
DA - 12160 North America — Version 7 — June 27, 2005
Page 5
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)(354100-B21)
NOTE:
NOTE:
NOTE: NOTE: upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.
PLUS
PLUS
PLUSPLUS
3.
Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the Cisco GESM which contains a single Switch per kit. One pair of interconnects is required with each blade enclosure: RJ-45 Patch Panel 2 with Fibre Channel pass through (required for Fibre Channel connectivity on HP ProLiant BL20p G3 when using the patch panel interconnect) (306465-B21) Or RJ-45 Patch Panel (230766-B21) Or Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch) Or Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000 T/TX/T SFP modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch) Or BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the GbE2 Interconnect Switch) Or BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for BLXXp server blade Fibre Channel connectivity when using the GbE2 Interconnect Switch) Or BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21) Or BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and 16 RJ-45 10/100 T/TX downlink ports) (279720-B21)
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field
PLUS
PLUS
PLUSPLUS
4.
Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration. Use p-Class sizing tool to help determine power configuration:
NOTE:
NOTE:
NOTE: NOTE:
Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a max of four power supplies) (239162-001) Or Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a max of six power supplies) (230769-001)
NOTE:
NOTE:
NOTE: NOTE:
Or 1U power enclosure with six power supplies (378284-B21) Or
Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
3U Power enclosures and supplies can also be purchased separately see options list
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
DA - 12160 North America — Version 7 — June 27, 2005
.
Page 6
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
1U power enclosure with two power supplies (380314-B21)
NOTE:
NOTE:
Additional power supplies can also be purchased separately - see options list below.
NOTE:NOTE:
PLUS
PLUS
PLUSPLUS
5.
Select power distribution (only required with 3U power enclosures): Scalable bus bar - Supports up to 5 server blade enclosures* (240560-B21) Or Mini bus bar - Supports up to 3 server blade enclosures* (240559-B21) Or Power Bus Box - Supports only 1 server blade enclosure* (240562-B21) Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. (364565-B21) Or HP Modular Distribution Unit 40 Amp (P/N 252663-D75) Or HP Modular Distribution Unit 24 Amp (P/N 252663-D74)
*
NOTE:
NOTE:
Maximum depends upon power input
NOTE:NOTE:
**
NOTE:
NOTE:
The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-
NOTE:NOTE:
class 1U power enclosure.
**
**
DA - 12160 North America — Version 7 — June 27, 2005
Page 7
QuickSpecs

Standard Features (Server Blade)

Processors
Processors
ProcessorsProcessors
Upgradeability
Upgradeability
UpgradeabilityUpgradeability
Cache Memory
Cache Memory
Cache MemoryCache Memory
Chipset
Chipset
ChipsetChipset
Memory
Memory
MemoryMemory
AMD Opteron Model 252 processor 2.6 GHz/1 GHz - 1MB (single-core) AMD Opteron Model 250 processor 2.4 GHz/800 MHz - 1MB (single-core) AMD Opteron Model 265 processor 1.8GHz/1 GHz (dual-core) AMD Opteron Model 270 processor 2.0GHz/1 GHz (dual-core) AMD Opteron Model 275 processor 2.2GHz/1 GHz (dual-core)
Upgradeable to dual processing.
1-MB Level 2 Cache per core
AMD 8131 and 8111 chipsets
Standard
Maximum
NOTE:
NOTE:
Memory must be installed in pairs.
NOTE:NOTE:
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
1024 MB or 2048 MB of 2-way interleaved PC3200 DDR SDRAM running at 400MHz (depending on model)
16 GB
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Manageability
Manageability
ManageabilityManageability
Internal Storage
Internal Storage
Internal StorageInternal Storage
Five network adapters total: Four PCI-X Gigabit NICs (embedded) with WOL and PXE (two single-port NC7781 and one dual-port
NC7782) One 10/100 iLO NIC dedicated to management
NOTE:
NOTE:
Must use a HP BladeSystem p-class server blade enclosure with enhanced backplane to utilize all
NOTE:NOTE: four NIC's (281404-B22, 243564-B22 or 380625-B22).
Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board)
Hard Drives Maximum Internal Storage
None ship standard 600 GB (internal drive cage) (2 x 300 GB Wide Ultra320, 1" drive
DA - 12160 North America — Version 7 — June 27, 2005
Page 8
QuickSpecs
Standard Features (Server Blade)
Fiber Channel on the
Fiber Channel on the
Fiber Channel on theFiber Channel on the HP ProLiant BL25p server
HP ProLiant BL25p server
HP ProLiant BL25p serverHP ProLiant BL25p server blade
blade
bladeblade
The following items are needed to connect the HP ProLiant BL25p server blade to the SAN:
1. HP ProLiant BL25/45p Dual-port Fibre Channel Adapter plugs into the Server Blades The HP ProLiant BL25/45p dual-port Fibre Channel Adapter is compatible with the new HP
ProLiant BL25p and BL45p server blades (it cannot be used with a HP ProLiant BL20p, HP ProLiant BL30p, HP ProLiant BL35p or HP ProLiant BL40p server blades) Two ports on each Dual-port Fibre Channel Mezzanine Card provide a redundant Fibre Channel connection to each server blade Supports up to 2 Gb/s Fibre Channel equipment Uses the QLogic chipset Includes two small form factor pluggable transceivers with LC connectors for installation into the Patch Panel 2, CGESM or GbE2 Interconnect Switch (with the Storage Connectivity Kit) The HP ProLiant BL25p Dual-port Fibre Channel Adapter Option Kit must be ordered separately. and
2A. BL p-Class Patch Panel 2 (with Fibre Channel pass through) interconnect option
Allows pass through of both Ethernet and Fibre Channel signals Ethernet signals exit out the rear of the RJ-45 Patch Panel G2; Fibre Channel signals exit out the front of the RJ-45 Patch Panel G2 8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the HP ProLiant BL25p Dual-port Fibre Channel kit or
2B. BL p-Class C-GbE2 or F-GbE2 or CGESM Interconnect Kit plus the optional Storage Connectivity Kit
Allows LAN signal consolidation and pass through of BL20p G3 Fibre Channel signals Both LAN Ethernet signals and SAN Fibre Channel signals exit out the rear of the GbE2 or CGESM Interconnect Switch (with the Storage Connectivity Kit option) via dedicated modular interconnect modules 8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the back of each GbE2 Interconnect Switch (16 Fibre Channel SPF slots per server blade enclosure) SPF transceivers are included with the HP ProLiant BL25p Dual-port Fibre Channel Adapter kit and
3. Compatible SAN Optimized for StorageWorks arrays: HSG80 (MA8000, EMA12000, EMA16000); EVA5000;
EVA3000; XP48, XP128, XP512, XP1024; HP StorageWorks Modular Smart Array 1000 and 1500 Compatible with select 3rd party SANs (please see blade storage page for more details
http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/storage.html
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
)
Expansion Slots
Expansion Slots
Expansion SlotsExpansion Slots
No PCI slots all features are integrated
I/O cable connectors:
I/O cable connectors:
I/O cable connectors:I/O cable connectors:
(2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port (2) I/O cables ship with every server blade enclosure Tested USB devices (keyboard, mouse, floppy) are listed in the "Options" section of this QuickSpecs
DA - 12160 North America — Version 7 — June 27, 2005
Page 9
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade

Standard Features (Server Blade Enclosure and Interconnects)

HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class InterconnectsHP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade Enclosures
Enclosures
EnclosuresEnclosures
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Power
p-Class Power
p-Class Powerp-Class Power Requirements
Requirements
RequirementsRequirements
6U (10.5-inch), 19-inch wide Holds up to 8 HP ProLiant BL25p servers blades 10 bays per server blade enclosure 8 bays for server blades 2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect
Switch, GbE2 Interconnect Switch or CGESM Interconnect Switch) Server blades blind mate into the server blade enclosure backplane for power and data connections
NOTE:
NOTE:
NOTE: NOTE: which HP ProLiant BL25p server blade model is selected.
http://www.hp.com/go/bladesystem/enclosure/compatibility
NOTE:
NOTE:
NOTE: NOTE: and enables a field upgrade of a blade enclosure to support specific HP ProLiant BL25p server blade models and provide a single, physical iLO port for the enclosure.
Server blade management module attached to the back of each HP BladeSystem p-Class 6U server blade enclosure to report events all servers and provide asset and inventory information
Redundant 200V - 240V AC, 30 amp single-phase Redundant 208V 30amp 3-phase 4 wire Redundant -48VDC ± 10%
HP BladeSystem p-Class Enhanced Server Blade enclosures might be required depending on
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch Option
Option
OptionOption
(Every HP BladeSystem p­Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels)
Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL25p, HP ProLiant BL30p, HP ProLiant BL35p, HP ProLiant BL40p and HP ProLiant BL45p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen internal server network (NIC) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure. Only one to all twelve external ports may be used per server blade enclosure.
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same and HP ProLiant BL25p Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect Switch or one CGESM with four (4) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two CGESM Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T or Fiber SX external ports per server blade enclosure. The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP ProLiant BL25p Fibre Channel pass-through when using either the CGESM Interconnect Kit.
DA - 12160 North America — Version 7 — June 27, 2005
Page 10
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL25p Fibre Channel pass-through.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure. The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP ProLiant BL25p Fibre Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ­45 10/100 T/TX external ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port Redundant crosslink ports connecting the two interconnect switches Redundant power inputs and on-board redundant fans Hot-plug and hot- remove with configuration retention and no need to cable/re-cable Power ON, management, and per port status and speed LED indicators Reset/power momentary push-button switch HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD Fully pre-configured for rapid deployment and immediate operation
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ­45 10/100 T/TX external ports per server blade enclosure.
ProLiant BL Interconnect Switch Management System and Utilities: Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level
user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more.
DA - 12160 North America — Version 7 — June 27, 2005
Page 11
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class Storage Connectivity Kit
Storage Connectivity Kit
Storage Connectivity KitStorage Connectivity Kit Option
Option
OptionOption (Supports two CGESM or GbE2 switches per kit)
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class RJ-45 Patch Panel
RJ-45 Patch Panel
RJ-45 Patch PanelRJ-45 Patch Panel (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)
The Storage Connectivity Kit is used if HP ProLiant BL25p Fibre Channel signal pass-through is desired when using the CGESM or GbE2 Interconnect Switch. Therefore, both LAN cable consolidation and SAN connectivity is possible using a single interconnect option. Order one Storage Connectivity Kit per server blade enclosure for Fibre Channel pass through. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver slots for the pluggable small form factor transceivers that come with each HP ProLiant BL25/45p Dual port Fibre Channel Adapter. The Storage Connectivity Kit supports up to eight HP ProLiant BL25p server blades (for a total of sixteen Fibre Channel signals).
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections
Supports Gigabit Ethernet network adapters
16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
ProLiant BL p-Class RJ-45
ProLiant BL p-Class RJ-45
ProLiant BL p-Class RJ-45ProLiant BL p-Class RJ-45 Patch Panel 2
Patch Panel 2
Patch Panel 2 Patch Panel 2 Channel pass through) (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)
NOTE:
NOTE:
The Patch Panel 2
NOTE:NOTE: or a Switch Interconnect Kit is required for SAN connectivity on the HP ProLiant BL25p server blade
Required Network
Required Network
Required NetworkRequired Network Cabling
Cabling
CablingCabling
(with Fibre
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections also
used to pass Fibre Channel signals for SAN connectivity Supports Gigabit Ethernet network adapters 16 RJ-45 connectors on the back of each RJ-45 patch panel 2 (32 RJ-45 connections per server blade
enclosure) Fibre Channel,
Fibre Channel,
Fibre Channel,Fibre Channel, pass through
pass through
pass throughpass through
10Base-T
100Base-TX
1000Base-T
1000Base-SX
NOTE:
NOTE:
NOTE: NOTE:
http://www.compaq.com/products/servers
For cabling information, refer to the Web site at:
Fibre Channel signals travel from a HP ProLiant BL25p server blade with a Dual-Port Fibre Channel Adapter through p-Class server blade enclosure backplane. The Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals and one Fibre Channel signal terminates through the right RJ-45 Patch Panel 2, one Fibre Channel signal travels terminates through the left RJ-45 Patch Panel 2.
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the Dual-port Fibre Channel Adapter
Categories 3, 4 or 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
50/125 µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 12
QuickSpecs

Standard Features (Power System and Rack Information)

HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Power System
p-Class Power System
p-Class Power Systemp-Class Power System and Rack Information
and Rack Information
and Rack Informationand Rack Information
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class 3U Power
p-Class 3U Power
p-Class 3U Powerp-Class 3U Power Enclosure
Enclosure
EnclosureEnclosure
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class 1U Power
p-Class 1U Power
p-Class 1U Powerp-Class 1U Power Enclosure
Enclosure
EnclosureEnclosure
NOTE:
NOTE:
NOTE: NOTE: Planning Whitepaper and sizing tool at
class/20p/index.html
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available.
HP BladeSystem p-Class 3U power enclosure provides external, shared hot-plug power. Each three­phase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures hold up to four hot-plug power supplies to power the BL p-Class server blades and interconnects Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully populated with BL p-Class server blades and interconnects. Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator.
NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
To determine power configuration please refer to the HP BladeSystem p-Class Overview and
http://h18000.www1.hp.com/products/servers/proliant-bl/p-
.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
.
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Power
p-Class Power
p-Class Powerp-Class Power Distribution (only required
Distribution (only required
Distribution (only requiredDistribution (only required with 3U power
with 3U power
with 3U powerwith 3U power enclosures)
enclosures)
enclosures)enclosures)
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the server blade enclosures through the bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack:
HP BladeSystem p-Class scalable bus bar HP BladeSystem p-Class mini bus bar HP BladeSystem p-Class power bus box
NOTE:
NOTE:
To support a full 42U rack of HP ProLiant BL25p server blades (6 server blade enclosures), two
NOTE:NOTE: mini bus bars are needed.
DA - 12160 North America — Version 7 — June 27, 2005
Page 13
QuickSpecs
Standard Features (Power System and Rack Information)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Scalable Bus Bar
Scalable Bus Bar
Scalable Bus BarScalable Bus Bar Mini Bus Bar
Mini Bus Bar
Mini Bus BarMini Bus Bar Power Bus Box
Power Bus Box
Power Bus BoxPower Bus Box
Required Power Source
Required Power Source
Required Power SourceRequired Power Source
Power Enclosures Supported
Power Enclosures Supported
Power Enclosures SupportedPower Enclosures Supported
1 or 2 1 or 2
1
Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures.
NOTE:
NOTE:
To support a full 42U rack
NOTE:NOTE: of BL p-Class server blades, use two stacked pairs of mini bus bars.
Two 30amp redundant power feeds per power enclosure Connectors
-NEMA receptacles
1-phase L6-30, 250v, 30A 3-wire 3-phase L15-30, 250V, 30A, 4-wire Optimized for power cabling from bottom and network cabling from top
Server Blade Enclosures
Server Blade Enclosures
Server Blade EnclosuresServer Blade Enclosures
Supported
Supported
SupportedSupported
up to 5 up to 3
1
Max. Rack Space Occupied
Max. Rack Space Occupied
Max. Rack Space OccupiedMax. Rack Space Occupied
36U 21U
9U
DA - 12160 North America — Version 7 — June 27, 2005
Page 14
Loading...
+ 31 hidden pages