HP 275 User Manual

QuickSpecs

Overview

42U Rack with HP ProLiant BL25p System Installed
42U Rack with HP ProLiant BL25p System Installed
42U Rack with HP ProLiant BL25p System Installed42U Rack with HP ProLiant BL25p System Installed
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
1.
BL p-Class interconnects (2) in HP BladeSystem p-Class server blade enclosure (interconnect switch shown)
2.
HP ProLiant BL25p server blades (8) in HP BladeSystem p-Class server blade enclosure
3.
HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6)
What's New
What's New
What's NewWhat's New
Models 275 (2.2GHz), 270 (2.0GHz) and 265 (1.8GHz)
1MB L2 cache per core New HP BladeSystem p-Class 1U Power Enclosure Up to two 2.6GHz AMD Opteron Processors with 1M L2 cache Up to 16GB ECC PC3200 DDR (8 DIMM slots) Integrated Smart Array 6i Plus with optional BBWC
DA - 12160 North America — Version 7 — June 27, 2005
Page 1
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
At A Glance
At A Glance
At A GlanceAt A Glance
Performance dual processor server blade designed with enterprise availability HP ProLiant BL25p server blade includes: AMD Opteron 200 series single and dual-core processors (dual capability)
Models 275 (2.2GHz), 270 (2.0GHz), 265 (1.8GHz), 252 (2.6GHz) and 250 (2.4GHz) HP ProLiant BL25p Dual Port Fibre Channel Adapter (2-Gb) option for SAN connectivity AMD 8131 and 8111 Chipsets 1024-MB or 2048-MB PC3200 Registered ECC 400MHz DDR memory, (2 x 1 Interleaved Memory), expandable to 16 GB Five total network adapters:
Four PCI-X Gigabit Server NICs (embedded) with WOL and PXE (two single-port NC7781 and one dual-port NC7782)
Plus one additional 10/100 NIC dedicated to iLO Management Smart Array 6i (integrated on system board Controller with optional battery-backed write cache) Wide Ultra320 SCSI Drive Cage standard supports up to two 1" Wide Ultra320 hot plug hard drives Integrated Lights-Out (iLO) Advanced Management (ASIC on motherboard) Plugs vertically into 6U enclosure, 8 BL25p server blades per enclosure Cisco Gigabit Ethernet Switch Module (CGESM) option for Gigabit Ethernet network adapter consolidation. Integrated Access Tool for blade management and enhanced server blade documentation including Best Practices and Common Procedures guides HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Server Blade Enclosure:HP BladeSystem p-Class Server Blade Enclosure:
Server blades and interconnects blind mate into server blade enclosures for network connection and power
Server blade enclosure is 6U and holds up to 8 HP ProLiant BL25p server blades and 2 interconnects
Types of interconnects available: GbE Interconnect Switches, GbE2 and CGESM Interconnect Switches with optional
Fibre Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Enclosures:HP BladeSystem p-Class Power Enclosures:
Use BL p-Class sizing tool to determine power based on your configuration
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
BL p-Class power enclosure provides shared, external, redundant power
Choose the HP BladeSystem p-Class 3U power enclosure or the HP BladeSystem p-Class 1U power enclosure
Choose single-phase or three-phase power
HP BladeSystem power enclosures with power supplies are not needed if using facility -48VDC ± 10%, in this case
purchase facility DC option kit HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
Distributes power from the power enclosure to the server blade enclosures
Four power distribution choices:
BL p-Class scalable bus bar
BL p-Class mini bus bar
BL p-Class power bus box
Dual power input kit for mini bus bar (required for support of two power enclosures) HP ProLiant BL25p server blade, and p-Class server blade enclosure, interconnects and power enclosure protected by a limited three year warranty with optional service uplifts available
NOTE:
NOTE:
NOTE: NOTE:
Power requirements for a HP BladeSystem p-Class-: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 2
QuickSpecs
Overview
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
++++
HP BladeSystem p-Class Server Blade Enclosure
HP BladeSystem p-Class Server Blade Enclosure
HP BladeSystem p-Class Server Blade EnclosureHP BladeSystem p-Class Server Blade Enclosure
++++
DA - 12160 North America — Version 7 — June 27, 2005
Page 3
QuickSpecs
Overview
OR
OR
OROR
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Patch Panel (shown) or
Patch Panel 2
BL p-Class Interconnects
BL p-Class Interconnects
BL p-Class InterconnectsBL p-Class Interconnects
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or
CGESM Interconnect Switch (fiber or copper-based)
++++
BL p-Class power enclosures and power supplies
BL p-Class power enclosures and power supplies
BL p-Class power enclosures and power suppliesBL p-Class power enclosures and power supplies
OR
OR
OROR
HP BladeSystem p-Class 1U power enclosure and power supplies
HP BladeSystem p-Class 1U power enclosure and power supplies
HP BladeSystem p-Class 1U power enclosure and power suppliesHP BladeSystem p-Class 1U power enclosure and power supplies
OR
OR
OROR
Facility DC
Facility DC
Facility DCFacility DC
DA - 12160 North America — Version 7 — June 27, 2005
Page 4
QuickSpecs
Overview
OR
OR OR
OROR
OR
OROR
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Scalable bus bar
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
Configuration Steps
Configuration Steps
Configuration StepsConfiguration Steps
For a complete configuration of the HP ProLiant BL25p server blade, do the following:
1.
Select desired model, configuration and quantity of HP ProLiant BL25p server blades.
PLUS
PLUS
PLUSPLUS
2.
Decide how many HP BladeSystem p-Class Server Blade Enclosures to purchase (each enclosure can hold up to 8 HP ProLiant BL25p server blades):
Mini bus bar
Bus boxes
Dual power input kit for mini bus bar
HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack licenses (281404-B22) Or HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack trial (243564-B22) Or HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 HP BladeSystem Management Suite licenses (380625-B22) - includes: a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM)
NOTE:
NOTE:
NOTE:NOTE: server blade model is selected. NOTE:
NOTE:
NOTE:NOTE:
Or
HP BladeSystem p-Class Enhanced Server Blade enclosures may be required depending on which HP ProLiant BL25p
The HP BL25p server blade does not currently support PMP. Future support is planned.
DA - 12160 North America — Version 7 — June 27, 2005
Page 5
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)(354100-B21)
NOTE:
NOTE:
NOTE: NOTE: upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.
PLUS
PLUS
PLUSPLUS
3.
Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the Cisco GESM which contains a single Switch per kit. One pair of interconnects is required with each blade enclosure: RJ-45 Patch Panel 2 with Fibre Channel pass through (required for Fibre Channel connectivity on HP ProLiant BL20p G3 when using the patch panel interconnect) (306465-B21) Or RJ-45 Patch Panel (230766-B21) Or Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch) Or Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000 T/TX/T SFP modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch) Or BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the GbE2 Interconnect Switch) Or BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for BLXXp server blade Fibre Channel connectivity when using the GbE2 Interconnect Switch) Or BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21) Or BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and 16 RJ-45 10/100 T/TX downlink ports) (279720-B21)
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field
PLUS
PLUS
PLUSPLUS
4.
Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration. Use p-Class sizing tool to help determine power configuration:
NOTE:
NOTE:
NOTE: NOTE:
Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a max of four power supplies) (239162-001) Or Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a max of six power supplies) (230769-001)
NOTE:
NOTE:
NOTE: NOTE:
Or 1U power enclosure with six power supplies (378284-B21) Or
Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
3U Power enclosures and supplies can also be purchased separately see options list
http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
DA - 12160 North America — Version 7 — June 27, 2005
.
Page 6
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
1U power enclosure with two power supplies (380314-B21)
NOTE:
NOTE:
Additional power supplies can also be purchased separately - see options list below.
NOTE:NOTE:
PLUS
PLUS
PLUSPLUS
5.
Select power distribution (only required with 3U power enclosures): Scalable bus bar - Supports up to 5 server blade enclosures* (240560-B21) Or Mini bus bar - Supports up to 3 server blade enclosures* (240559-B21) Or Power Bus Box - Supports only 1 server blade enclosure* (240562-B21) Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. (364565-B21) Or HP Modular Distribution Unit 40 Amp (P/N 252663-D75) Or HP Modular Distribution Unit 24 Amp (P/N 252663-D74)
*
NOTE:
NOTE:
Maximum depends upon power input
NOTE:NOTE:
**
NOTE:
NOTE:
The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-
NOTE:NOTE:
class 1U power enclosure.
**
**
DA - 12160 North America — Version 7 — June 27, 2005
Page 7
QuickSpecs

Standard Features (Server Blade)

Processors
Processors
ProcessorsProcessors
Upgradeability
Upgradeability
UpgradeabilityUpgradeability
Cache Memory
Cache Memory
Cache MemoryCache Memory
Chipset
Chipset
ChipsetChipset
Memory
Memory
MemoryMemory
AMD Opteron Model 252 processor 2.6 GHz/1 GHz - 1MB (single-core) AMD Opteron Model 250 processor 2.4 GHz/800 MHz - 1MB (single-core) AMD Opteron Model 265 processor 1.8GHz/1 GHz (dual-core) AMD Opteron Model 270 processor 2.0GHz/1 GHz (dual-core) AMD Opteron Model 275 processor 2.2GHz/1 GHz (dual-core)
Upgradeable to dual processing.
1-MB Level 2 Cache per core
AMD 8131 and 8111 chipsets
Standard
Maximum
NOTE:
NOTE:
Memory must be installed in pairs.
NOTE:NOTE:
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
1024 MB or 2048 MB of 2-way interleaved PC3200 DDR SDRAM running at 400MHz (depending on model)
16 GB
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Manageability
Manageability
ManageabilityManageability
Internal Storage
Internal Storage
Internal StorageInternal Storage
Five network adapters total: Four PCI-X Gigabit NICs (embedded) with WOL and PXE (two single-port NC7781 and one dual-port
NC7782) One 10/100 iLO NIC dedicated to management
NOTE:
NOTE:
Must use a HP BladeSystem p-class server blade enclosure with enhanced backplane to utilize all
NOTE:NOTE: four NIC's (281404-B22, 243564-B22 or 380625-B22).
Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board)
Hard Drives Maximum Internal Storage
None ship standard 600 GB (internal drive cage) (2 x 300 GB Wide Ultra320, 1" drive
DA - 12160 North America — Version 7 — June 27, 2005
Page 8
QuickSpecs
Standard Features (Server Blade)
Fiber Channel on the
Fiber Channel on the
Fiber Channel on theFiber Channel on the HP ProLiant BL25p server
HP ProLiant BL25p server
HP ProLiant BL25p serverHP ProLiant BL25p server blade
blade
bladeblade
The following items are needed to connect the HP ProLiant BL25p server blade to the SAN:
1. HP ProLiant BL25/45p Dual-port Fibre Channel Adapter plugs into the Server Blades The HP ProLiant BL25/45p dual-port Fibre Channel Adapter is compatible with the new HP
ProLiant BL25p and BL45p server blades (it cannot be used with a HP ProLiant BL20p, HP ProLiant BL30p, HP ProLiant BL35p or HP ProLiant BL40p server blades) Two ports on each Dual-port Fibre Channel Mezzanine Card provide a redundant Fibre Channel connection to each server blade Supports up to 2 Gb/s Fibre Channel equipment Uses the QLogic chipset Includes two small form factor pluggable transceivers with LC connectors for installation into the Patch Panel 2, CGESM or GbE2 Interconnect Switch (with the Storage Connectivity Kit) The HP ProLiant BL25p Dual-port Fibre Channel Adapter Option Kit must be ordered separately. and
2A. BL p-Class Patch Panel 2 (with Fibre Channel pass through) interconnect option
Allows pass through of both Ethernet and Fibre Channel signals Ethernet signals exit out the rear of the RJ-45 Patch Panel G2; Fibre Channel signals exit out the front of the RJ-45 Patch Panel G2 8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the HP ProLiant BL25p Dual-port Fibre Channel kit or
2B. BL p-Class C-GbE2 or F-GbE2 or CGESM Interconnect Kit plus the optional Storage Connectivity Kit
Allows LAN signal consolidation and pass through of BL20p G3 Fibre Channel signals Both LAN Ethernet signals and SAN Fibre Channel signals exit out the rear of the GbE2 or CGESM Interconnect Switch (with the Storage Connectivity Kit option) via dedicated modular interconnect modules 8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the back of each GbE2 Interconnect Switch (16 Fibre Channel SPF slots per server blade enclosure) SPF transceivers are included with the HP ProLiant BL25p Dual-port Fibre Channel Adapter kit and
3. Compatible SAN Optimized for StorageWorks arrays: HSG80 (MA8000, EMA12000, EMA16000); EVA5000;
EVA3000; XP48, XP128, XP512, XP1024; HP StorageWorks Modular Smart Array 1000 and 1500 Compatible with select 3rd party SANs (please see blade storage page for more details
http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/storage.html
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
)
Expansion Slots
Expansion Slots
Expansion SlotsExpansion Slots
No PCI slots all features are integrated
I/O cable connectors:
I/O cable connectors:
I/O cable connectors:I/O cable connectors:
(2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port (2) I/O cables ship with every server blade enclosure Tested USB devices (keyboard, mouse, floppy) are listed in the "Options" section of this QuickSpecs
DA - 12160 North America — Version 7 — June 27, 2005
Page 9
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade

Standard Features (Server Blade Enclosure and Interconnects)

HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class InterconnectsHP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade Enclosures
Enclosures
EnclosuresEnclosures
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Power
p-Class Power
p-Class Powerp-Class Power Requirements
Requirements
RequirementsRequirements
6U (10.5-inch), 19-inch wide Holds up to 8 HP ProLiant BL25p servers blades 10 bays per server blade enclosure 8 bays for server blades 2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect
Switch, GbE2 Interconnect Switch or CGESM Interconnect Switch) Server blades blind mate into the server blade enclosure backplane for power and data connections
NOTE:
NOTE:
NOTE: NOTE: which HP ProLiant BL25p server blade model is selected.
http://www.hp.com/go/bladesystem/enclosure/compatibility
NOTE:
NOTE:
NOTE: NOTE: and enables a field upgrade of a blade enclosure to support specific HP ProLiant BL25p server blade models and provide a single, physical iLO port for the enclosure.
Server blade management module attached to the back of each HP BladeSystem p-Class 6U server blade enclosure to report events all servers and provide asset and inventory information
Redundant 200V - 240V AC, 30 amp single-phase Redundant 208V 30amp 3-phase 4 wire Redundant -48VDC ± 10%
HP BladeSystem p-Class Enhanced Server Blade enclosures might be required depending on
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch Option
Option
OptionOption
(Every HP BladeSystem p­Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels)
Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL25p, HP ProLiant BL30p, HP ProLiant BL35p, HP ProLiant BL40p and HP ProLiant BL45p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen internal server network (NIC) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure. Only one to all twelve external ports may be used per server blade enclosure.
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same and HP ProLiant BL25p Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect Switch or one CGESM with four (4) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two CGESM Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T or Fiber SX external ports per server blade enclosure. The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP ProLiant BL25p Fibre Channel pass-through when using either the CGESM Interconnect Kit.
DA - 12160 North America — Version 7 — June 27, 2005
Page 10
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL25p Fibre Channel pass-through.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure. The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP ProLiant BL25p Fibre Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ­45 10/100 T/TX external ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port Redundant crosslink ports connecting the two interconnect switches Redundant power inputs and on-board redundant fans Hot-plug and hot- remove with configuration retention and no need to cable/re-cable Power ON, management, and per port status and speed LED indicators Reset/power momentary push-button switch HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD Fully pre-configured for rapid deployment and immediate operation
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per server blade enclosure. The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ­45 10/100 T/TX external ports per server blade enclosure.
ProLiant BL Interconnect Switch Management System and Utilities: Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level
user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more.
DA - 12160 North America — Version 7 — June 27, 2005
Page 11
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class Storage Connectivity Kit
Storage Connectivity Kit
Storage Connectivity KitStorage Connectivity Kit Option
Option
OptionOption (Supports two CGESM or GbE2 switches per kit)
ProLiant BL p-Class
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class RJ-45 Patch Panel
RJ-45 Patch Panel
RJ-45 Patch PanelRJ-45 Patch Panel (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)
The Storage Connectivity Kit is used if HP ProLiant BL25p Fibre Channel signal pass-through is desired when using the CGESM or GbE2 Interconnect Switch. Therefore, both LAN cable consolidation and SAN connectivity is possible using a single interconnect option. Order one Storage Connectivity Kit per server blade enclosure for Fibre Channel pass through. The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open transceiver slots for the pluggable small form factor transceivers that come with each HP ProLiant BL25/45p Dual port Fibre Channel Adapter. The Storage Connectivity Kit supports up to eight HP ProLiant BL25p server blades (for a total of sixteen Fibre Channel signals).
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections
Supports Gigabit Ethernet network adapters
16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per server blade enclosure)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
ProLiant BL p-Class RJ-45
ProLiant BL p-Class RJ-45
ProLiant BL p-Class RJ-45ProLiant BL p-Class RJ-45 Patch Panel 2
Patch Panel 2
Patch Panel 2 Patch Panel 2 Channel pass through) (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)
NOTE:
NOTE:
The Patch Panel 2
NOTE:NOTE: or a Switch Interconnect Kit is required for SAN connectivity on the HP ProLiant BL25p server blade
Required Network
Required Network
Required NetworkRequired Network Cabling
Cabling
CablingCabling
(with Fibre
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections also
used to pass Fibre Channel signals for SAN connectivity Supports Gigabit Ethernet network adapters 16 RJ-45 connectors on the back of each RJ-45 patch panel 2 (32 RJ-45 connections per server blade
enclosure) Fibre Channel,
Fibre Channel,
Fibre Channel,Fibre Channel, pass through
pass through
pass throughpass through
10Base-T
100Base-TX
1000Base-T
1000Base-SX
NOTE:
NOTE:
NOTE: NOTE:
http://www.compaq.com/products/servers
For cabling information, refer to the Web site at:
Fibre Channel signals travel from a HP ProLiant BL25p server blade with a Dual-Port Fibre Channel Adapter through p-Class server blade enclosure backplane. The Fibre Channel signals are terminated through the RJ-45 Patch Panel 2 in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals and one Fibre Channel signal terminates through the right RJ-45 Patch Panel 2, one Fibre Channel signal travels terminates through the left RJ-45 Patch Panel 2.
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF transceivers included with the Dual-port Fibre Channel Adapter
Categories 3, 4 or 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters)
50/125 µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 12
QuickSpecs

Standard Features (Power System and Rack Information)

HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Power System
p-Class Power System
p-Class Power Systemp-Class Power System and Rack Information
and Rack Information
and Rack Informationand Rack Information
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class 3U Power
p-Class 3U Power
p-Class 3U Powerp-Class 3U Power Enclosure
Enclosure
EnclosureEnclosure
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class 1U Power
p-Class 1U Power
p-Class 1U Powerp-Class 1U Power Enclosure
Enclosure
EnclosureEnclosure
NOTE:
NOTE:
NOTE: NOTE: Planning Whitepaper and sizing tool at
class/20p/index.html
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available.
HP BladeSystem p-Class 3U power enclosure provides external, shared hot-plug power. Each three­phase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures hold up to four hot-plug power supplies to power the BL p-Class server blades and interconnects Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully populated with BL p-Class server blades and interconnects. Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator.
NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
To determine power configuration please refer to the HP BladeSystem p-Class Overview and
http://h18000.www1.hp.com/products/servers/proliant-bl/p-
.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
.
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Power
p-Class Power
p-Class Powerp-Class Power Distribution (only required
Distribution (only required
Distribution (only requiredDistribution (only required with 3U power
with 3U power
with 3U powerwith 3U power enclosures)
enclosures)
enclosures)enclosures)
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the server blade enclosures through the bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack:
HP BladeSystem p-Class scalable bus bar HP BladeSystem p-Class mini bus bar HP BladeSystem p-Class power bus box
NOTE:
NOTE:
To support a full 42U rack of HP ProLiant BL25p server blades (6 server blade enclosures), two
NOTE:NOTE: mini bus bars are needed.
DA - 12160 North America — Version 7 — June 27, 2005
Page 13
QuickSpecs
Standard Features (Power System and Rack Information)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Scalable Bus Bar
Scalable Bus Bar
Scalable Bus BarScalable Bus Bar Mini Bus Bar
Mini Bus Bar
Mini Bus BarMini Bus Bar Power Bus Box
Power Bus Box
Power Bus BoxPower Bus Box
Required Power Source
Required Power Source
Required Power SourceRequired Power Source
Power Enclosures Supported
Power Enclosures Supported
Power Enclosures SupportedPower Enclosures Supported
1 or 2 1 or 2
1
Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures.
NOTE:
NOTE:
To support a full 42U rack
NOTE:NOTE: of BL p-Class server blades, use two stacked pairs of mini bus bars.
Two 30amp redundant power feeds per power enclosure Connectors
-NEMA receptacles
1-phase L6-30, 250v, 30A 3-wire 3-phase L15-30, 250V, 30A, 4-wire Optimized for power cabling from bottom and network cabling from top
Server Blade Enclosures
Server Blade Enclosures
Server Blade EnclosuresServer Blade Enclosures
Supported
Supported
SupportedSupported
up to 5 up to 3
1
Max. Rack Space Occupied
Max. Rack Space Occupied
Max. Rack Space OccupiedMax. Rack Space Occupied
36U 21U
9U
DA - 12160 North America — Version 7 — June 27, 2005
Page 14
QuickSpecs

Standard Features

ProLiant Essentials
ProLiant Essentials
ProLiant EssentialsProLiant Essentials Foundation Pack
Foundation Pack
Foundation PackFoundation Pack Software for the ProLiant
Software for the ProLiant
Software for the ProLiantSoftware for the ProLiant BL Server Blades
BL Server Blades
BL Server BladesBL Server Blades
ProLiant Essentials Rapid Deployment Pack
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the Altiris Deployment Solution and ProLiant Integration Module featuring ProLiant server pre-configured events for OS installation, and optimized software drivers, firmware and management agents. Every RDP CD includes 10-node trial licenses for evaluation purposes. RDP requires a license for each server deployed and is available for purchase with blade servers. For more information, visit
http://www.hp.com/servers/rdp
.
HP Systems Insight Manager
Management Agents
Subscriber's Choice
HP Systems Insight Manager (HP SIM) help maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM is easy to set up to work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Out Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP Systems Insight Manager customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP Systems Insight Manager visit
http://www.hp.com/go/hpsim
The Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to in­depth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to HP Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from HP, please visit the management Web site at
http://www.hp.com/servers/manage
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at
http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
.
.
ROMPaq software, and configuration utilities
Insight Diagnostics Online Edition
NOTE:
NOTE:
NOTE: NOTE:
http://www.hp.com/servers/proliantessentials
, support
For more information regarding ProLiant Essentials Software, please see the following URL:
DA - 12160 North America — Version 7 — June 27, 2005
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available in the RDP CD, SmartStart or downloadable from Software and Drivers download pages, linked from the SmartStart website at
The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in SmartStart.
http://www.hp.com/go/support
.
Page 15
QuickSpecs
Standard Features
Optional ProLiant
Optional ProLiant
Optional ProLiantOptional ProLiant Essentials Value Packs
Essentials Value Packs
Essentials Value PacksEssentials Value Packs
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
Workload Management Pack - provides easier management of complex environments, improving overall server utilization and enabling Windows® 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server. Performance Management Pack - a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources. Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages and steers traffic to the optimum route based on network conditions. Vulnerability and Patch management Pack - identifies and remediates software security vulnerabilities due to missing patches as well operating system configurations that can be exploited by viruses, worms and other blended threats. Virtual Machine Management Pack - provides central management and control of virtual machines from Microsoft and VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management console.
NOTE:
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer
NOTE:NOTE: to
http://www.hp.com/servers/proliantessentials
QuickSpecs for more information.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
or the various ProLiant Essentials Value Pack product
SmartStart
SmartStart
SmartStartSmartStart
OS Support:
OS Support:
OS Support:OS Support: Single-Core
Single-Core
Single-CoreSingle-Core
2.4 GHz and 2.6 GHz
2.4 GHz and 2.6 GHz
2.4 GHz and 2.6 GHz2.4 GHz and 2.6 GHz models
models
modelsmodels
SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and consistent server configurations. SmartStart 7.30 and later can now deploy all HP ProLiant BL25p server blades, using the I/O port with an attached USB CD-ROM device. To obtain a copy of SmartStart for your blade server, redeem the coupon that is included with your Blade server or order your copy from the SmartStart web site. For more information, please visit the SmartStart Web site at
http://www.hp.com/servers/smartstart
SmartStart version supported (minimum): SmartStart 6.20
Microsoft Windows 2000 Server Microsoft Windows 2000 Advanced Server Windows Server 2003, Standard Edition Windows Server 2003, Enterprise Edition Red Hat Enterprise Linux 3 Red Hat Enterprise Linux 4 SuSE Linux Enterprise Server 8 SuSE Linux Enterprise Server 9
NOTE:
NOTE:
For a complete and up-to-date listing of supported OSs and versions, please visit our OS
NOTE:NOTE: Support Matrix at: NOTE:
NOTE:
For an up-to-date listing of the latest drivers available for the HP ProLiant BL p-Class, please see:
NOTE:NOTE:
http://h18004.www1.hp.com/support/files/server/us/family/model/5342.html
NOTE:
NOTE:
For a more complete and up-to-date information on Linux support, please visit HP Linux Web
NOTE:NOTE: site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html
http://www.hp.com/go/supportos
.
.
.
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 16
QuickSpecs
Standard Features
OS Support:
OS Support:
OS Support:OS Support: Dual-Core
Dual-Core
Dual-CoreDual-Core
1.8 GHz, 2.0 GHz and
1.8 GHz, 2.0 GHz and
1.8 GHz, 2.0 GHz and1.8 GHz, 2.0 GHz and
2.2 GHz models
2.2 GHz models
2.2 GHz models2.2 GHz models
Intelligent Manageability
Intelligent Manageability
Intelligent ManageabilityIntelligent Manageability
Microsoft Windows 2000 Server (licensed by core) Microsoft Windows 2000 Advanced Server (licensed by core) Windows Server 2003, Standard Edition (licensed by processor socket) Windows Server 2003, Enterprise Edition (licensed by processor socket) Red Hat Enterprise Linux 3 Update 5 Red Hat Enterprise Linux 4 Update 2 SuSE Linux Enterprise Server 9 SP1 NOTE:
NOTE:
For a complete and up-to-date listing of supported OSs and versions, please visit our OS
NOTE:NOTE: Support Matrix at: http://www.hp.com/go/supportos NOTE:
NOTE:
For an up-to-date listing of the latest drivers available for the HP ProLiant BL p-Class, please see
NOTE:NOTE:
http://h18004.www1.hp.com/support/files/server/us/family/model/5342.html
NOTE:
NOTE:
For a more complete and up-to-date information on Linux support, please visit HP Linux Web
NOTE:NOTE: site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html
Integrated Lights-Out Advanced (iLO)
Virtual Text and Graphical Remote Console * Virtual CD-ROM* Virtual Floppy * Virtual Power Button Control Dedicated LAN Connectivity Automatic IP Configuration via DHCP/DNS/WINS Industry Standard 128-bit Secure Sockets Layer (SSL) Security IML and iLO Event Logging Support for 12 user accounts with customizable access privileges
Automatic Server Recovery-2 (ASR-2) Insight Manager 7 HP Systems Insight Manager Redundant ROM Remote Flash ROM ROM Based Setup Utility (RBSU) Advanced Configuration and Power Interface Specification Ready (ACPI) Server and Interconnect Switch Health Logs Redundant Power Supply Utility Pre-Failure Warranty (covers processors, as well as hard drives and memory) Interconnect Switch Management System and Utilities (Interconnect Switch option) Integrated Management Log (IML) Off-Line Backup Processor capability Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Network adapter teaming set-up utility
* Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL p­Class server.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
.
:
.
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 17
QuickSpecs
Standard Features
Availability
Availability
AvailabilityAvailability
Power redundancy: Redundant AC feeds into power enclosures, redundant DC feeds from power enclosure to server blade enclosures, N + N redundant power supplies Dual-Port Fibre Channel Mezzanine Card for redundant SAN connection Two hot-plug SCSI hard drive bays and integrated RAID (Smart Array 6i Plus) on every server blade (Battery-backed write cache is optional.) Redundant ROM on each server blade ECC Memory Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing) Interconnects Switch Availability
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable Two network connections per server blade bay (four NICs total) routed to two redundant interconnect switches Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports per each interconnect switch Redundant front panel ports per each interconnect switch for diagnostics, management, and additional uplinks Redundant serial ports Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning tree protocol support for loop-free path redundancy Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and failover Redundant configuration files and operating system firmware images in memory (GbE2 switch) Redundant fans per each interconnect switch Redundant 1+1 power to each interconnect switch Support for ProLiant network adapter teaming Redundant configurable community strings and SNMP trap manager hosts Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Security
Security
SecuritySecurity
Power-on password Administrator's password Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction
* CGESM and GbE2 Interconnect Switch only
DA - 12160 North America — Version 7 — June 27, 2005
Page 18
QuickSpecs
Standard Features
Minimum Rack
Minimum Rack
Minimum RackMinimum Rack Requirements
Requirements
RequirementsRequirements
Rack Airflow
Rack Airflow
Rack AirflowRack Airflow Requirements
Requirements
RequirementsRequirements
Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria:
Compatible with 19-inch Standard EIA rail sets EIA rail-to-rail depth is 29 - 30" Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear RETMA rail to rear door, inclusive in the 36-inch overall depth) Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration with patch panel) Must be capable of supporting 1600 lb (for full rack configuration) Perforated front and rear doors to accommodate front-to-back cooling Must have 65% open perforation on server blade enclosure doors to support airflow requirements Optimized for use with the HP 10000 Series racks
NOTE:
NOTE:
If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are
NOTE:NOTE: required.
Rack 10000 series Cabinets
Rack 10000 series Cabinets
Rack 10000 series CabinetsRack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION:CAUTION: adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION:
CAUTION:CAUTION: arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE:
NOTE:
NOTE: NOTE: provided with the server, or to the server documentation located in the Support section at the following URL:
http://www.hp.com/servers/bl25p
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
If a third-party rack is used, observe the following additional requirements to ensure
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
For additional information, refer to the Setup and Installation Guide or the Documentation CD
.
Factory Express Portfolio
Factory Express Portfolio
Factory Express PortfolioFactory Express Portfolio for Servers and Storage
for Servers and Storage
for Servers and Storagefor Servers and Storage
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging and custom packaging. HP products supported through Factory Express include: a wide array of servers and storage: HP Integrity, HP ProLiant & HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales representative or go to
DA - 12160 North America — Version 7 — June 27, 2005
http://www.hp.com/go/factory-express
.
Page 19
QuickSpecs
Standard Features
Service and Support
Service and Support
Service and SupportService and Support
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services.
NOTE:
NOTE:
Sever Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
NOTE:NOTE: NOTE:
NOTE:
Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor,
NOTE:NOTE: 3-year on-site support.
Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up Education courses Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWare-based IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours. System Management, Performance Services and Mission Critical Support Solution
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the HP BladeSystem p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution.
NOTE:
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales offices or
NOTE:NOTE: resellers or visit our worldwide Web site on the internet at: NOTE:
NOTE:
For more complete information on HP Services offerings, customers and resellers, please visit us
NOTE:NOTE: at:
http://www.hp.com/hps
NOTE:
NOTE:
Additional information regarding worldwide limited warranty and technical support is available
NOTE:NOTE: at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
http://www.hp.com/hps/carepack
DA - 12160 North America — Version 7 — June 27, 2005
Page 20
QuickSpecs

Models

ProLiant BL25p 1.8GHz-
ProLiant BL25p 1.8GHz-
ProLiant BL25p 1.8GHz-ProLiant BL25p 1.8GHz­1MB,DC 1GB (1P)
1MB,DC 1GB (1P)
1MB,DC 1GB (1P)1MB,DC 1GB (1P) 392443-B21
ProLiant BL25p 2.0GHz-
ProLiant BL25p 2.0GHz-
ProLiant BL25p 2.0GHz-ProLiant BL25p 2.0GHz­1MB, DC 2GB (2P)
1MB, DC 2GB (2P)
1MB, DC 2GB (2P)1MB, DC 2GB (2P) 392441-B21
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller Hard Drives
Hard Drives
Hard DrivesHard Drives Internal Storage
Internal Storage
Internal StorageInternal Storage Optical Drive
Optical Drive
Optical DriveOptical Drive Form Factor
Form Factor
Form FactorForm Factor
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller Hard Drives
Hard Drives
Hard DrivesHard Drives Internal Storage
Internal Storage
Internal StorageInternal Storage Optical Drive
Optical Drive
Optical DriveOptical Drive Form Factor
Form Factor
Form FactorForm Factor
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
(1) AMD Opteron Model 265 dual-core 1.8 GHz standard (up to 2 supported)
1-MB Level 2 cache per core 1024-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (2x512 MB) Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management Smart Array 6i Controller (integrated on system board) None ship standard Up to 600-GB maximum (with optional hard drives) None Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
(2) AMD Opteron Model 270 dual-core 2.0 GHz standard (up to 2 supported)
1-MB Level 2 cache per core 2048-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (4x512 MB) Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management Smart Array 6i Controller (integrated on system board) None ship standard Up to 600-GB maximum (with optional hard drives) None Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
ProLiant BL25p 2.2GHz-
ProLiant BL25p 2.2GHz-
ProLiant BL25p 2.2GHz-ProLiant BL25p 2.2GHz­1MB, DC 2GB (2P)
1MB, DC 2GB (2P)
1MB, DC 2GB (2P)1MB, DC 2GB (2P) 392439-B21
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller Hard Drives
Hard Drives
Hard DrivesHard Drives Internal Storage
Internal Storage
Internal StorageInternal Storage Optical Drive
Optical Drive
Optical DriveOptical Drive Form Factor
Form Factor
Form FactorForm Factor
DA - 12160 North America — Version 7 — June 27, 2005
(2) AMD Opteron Model 275 dual-core 2.2 GHz standard (up to 2 supported)
1-MB Level 2 cache per core 2048-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (4x512 MB) Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management Smart Array 6i Controller (integrated on system board) None ship standard Up to 600-GB maximum (with optional hard drives) None Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
Page 21
QuickSpecs
Models
ProLiant BL25p 2.4GHz-
ProLiant BL25p 2.4GHz-
ProLiant BL25p 2.4GHz-ProLiant BL25p 2.4GHz­1MB, 1GB (1P)
1MB, 1GB (1P)
1MB, 1GB (1P)1MB, 1GB (1P) 374797-B21
ProLiant BL25p 2.6GHz-
ProLiant BL25p 2.6GHz-
ProLiant BL25p 2.6GHz-ProLiant BL25p 2.6GHz­1MB, 1GB (1P)
1MB, 1GB (1P)
1MB, 1GB (1P)1MB, 1GB (1P) 374798-B21
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller Hard Drives
Hard Drives
Hard DrivesHard Drives Internal Storage
Internal Storage
Internal StorageInternal Storage Optical Drive
Optical Drive
Optical DriveOptical Drive Form Factor
Form Factor
Form FactorForm Factor
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller Hard Drives
Hard Drives
Hard DrivesHard Drives Internal Storage
Internal Storage
Internal StorageInternal Storage Optical Drive
Optical Drive
Optical DriveOptical Drive Form Factor
Form Factor
Form FactorForm Factor
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
(1) AMD Opteron Model 250 single-core 2.4 GHz standard (up to 2 supported)
1-MB Level 2 cache per core 1024-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (2x512MB) Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management Smart Array 6i Controller (integrated on system board) None ship standard Up to 600-GB maximum (with optional hard drives) None Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
(1) AMD Opteron Model 252 single-core 2.6 GHz standard (up to 2 supported)
1-MB Level 2 cache per core 1024-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (2x512MB) Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management Smart Array 6i Controller (integrated on system board) None ship standard Up to 600-GB maximum (with optional hard drives) None Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
ProLiant BL25p 2.6Ghz-
ProLiant BL25p 2.6Ghz-
ProLiant BL25p 2.6Ghz-ProLiant BL25p 2.6Ghz­1MB, 2GB (2P)
1MB, 2GB (2P)
1MB, 2GB (2P)1MB, 2GB (2P) 374799-B21
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller Hard Drives
Hard Drives
Hard DrivesHard Drives Internal Storage
Internal Storage
Internal StorageInternal Storage Optical Drive
Optical Drive
Optical DriveOptical Drive Form Factor
Form Factor
Form FactorForm Factor
DA - 12160 North America — Version 7 — June 27, 2005
(2) AMD Opteron Model 252 single-core 2.6 GHz standard (up to 2 supported)
1-MB Level 2 cache per core 2048-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (4x512MB) Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management Smart Array 6i Controller (integrated on system board) None ship standard Up to 600-GB maximum (with optional hard drives) None Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
Page 22
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade

Configuration Information Factory Integrated Models

NOTE:
NOTE:
NOTE: NOTE: Configure-to-order servers must start with a CTO Chassis.
NOTE:
NOTE:
NOTE: NOTE:
Step 1: Base Server Blade Configuration
Step 1: Base Server Blade Configuration
Step 1: Base Server Blade ConfigurationStep 1: Base Server Blade Configuration
Models
Models
ModelsModels
Step 2: Choose Required Options (one of the following from each list unless otherwise
Step 2: Choose Required Options (one of the following from each list unless otherwise
Step 2: Choose Required Options (one of the following from each list unless otherwiseStep 2: Choose Required Options (one of the following from each list unless otherwise noted):
noted):
noted):noted):
Processors
Processors
ProcessorsProcessors
Memory
Memory
MemoryMemory
Communications
Communications
CommunicationsCommunications
HP does not allow factory integration of options into standard models listed above.
This product offering does not support HP Factory Express Server Configuration Level 1.
HP ProLiant BL25p CTO Blade Configurable Model ships with:
Configurable Model ships with:
Configurable Model ships with:Configurable Model ships with: One additional 10/100 NIC dedicated to iLO Management Four Gigabit NICs
(embedded) with WOL and PXE
NOTE:
NOTE:
Two can be upgraded to multifunction network adapters)
NOTE:NOTE:
One additional 10/100 NIC dedicated to iLO Management
HP BL25p 0265 1.8GHz DC FIO Base HP BL25p 0270 2.0GHz DC FIO Base HP BL25p 0275 2.2GHz DC FIO Base HP BL25p O252 2.6GHz SC FIO Base HP BL25p O250 2.4GHz SC FIO Base For dual processor configurations choose one of the above FIO choices, plus one of
the matching option kits below: HP BL25p Opteron 2.2GHz-1M DC Processor Option Kit HP BL25p Opteron 2.0GHz-1M DC Processor Option Kit HP BL25p Opteron 1.8GHz-1M DC Processor Option Kit HP BL25p Opteron 2.6GHz-1M SC Processor Option Kit HP BL25p Opteron 2.4GHz-1M SC Processor Option Kit
NOTE:
NOTE:
Two-way memory interleaving is enabled when an identical pair of DIMMs is
NOTE:NOTE: installed.
1GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
NOTE:
NOTE:
Must install in pairs
NOTE:NOTE:
2GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) 4GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
NOTE:
NOTE:
NOTE: NOTE:
HP ProLiant BL25/35/45p NIC Mezz FIO Base
Must install in pairs
382731-405
392444-L21 392442-L21 392440-L21 381588-L21 381587-L21
392440-B21 392442-B21 392444-B21 381588-B21 381587-B21
376638-B21
376639-B21 379300-B21
382850-B21
Step 3: Choose Additional Factory Integratable Options
Step 3: Choose Additional Factory Integratable Options
Step 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integratable Options
Fibre Channel Options
Fibre Channel Options
Fibre Channel OptionsFibre Channel Options
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory IntegrationStep 4: Choose Additional Options for Factory Integration
NOTE:
NOTE:
NOTE: NOTE: subsystem options, please refer to the "Options" section below.
For additional options, including server blade enclosure with enhanced backplanes, interconnect options and power
FC Adapter Card BL25p/45p
DA - 12160 North America — Version 7 — June 27, 2005
381881-B21
Page 23
QuickSpecs

Options

ProLiant Essentials
ProLiant Essentials
ProLiant EssentialsProLiant Essentials Value Pack Software
Value Pack Software
Value Pack SoftwareValue Pack Software
ProLiant Essentials Vulnerability and Patch Management Pack, 1 Server + 10Desktop Bundle License
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity
License ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for
New Servers ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for
Installed servers ProLiant Essentials Server Migration Pack, 25-Server License ProLiant Essentials Server Migration Pack, 50-Server License ProLiant Essentials Server Migration Pack, 100-Server License ProLiant Essentials Server Migration Pack, 10-Server License
NOTE:
NOTE:
This license allows 10 servers to be migrated from a physical server to 10
NOTE:NOTE: virtual machines. Or this license can be used to migrate 10 virtual machines from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005.
ProLiant Essentials Server Migration Pack, Single-Server License ProLiant Essentials Server Migration Pack, Flexible-Quantity License ProLiant Essentials Server Migration Pack, Tracking license ProLiant Essentials Virtual Machine Management Pack, SINGLE LIC IP CCAO-
WGR ProLiant Essentials Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-
WGR ProLiant Essentials Intelligent Networking Pack, Single Server License
NOTE:
NOTE:
NOTE: NOTE: activation key and documentation.
ProLiant Essentials Intelligent Networking Pack, Flexible License
NOTE:
NOTE:
NOTE: NOTE: multiple licenses with a single activation key. The quantity ordered for this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with the activation key, and documentation.
ProLiant Essentials Intelligent Networking Pack, Tracking License
NOTE:
NOTE:
NOTE: NOTE: Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE:
NOTE:
Nothing is delivered in conjunction with the purchase of this part number. Visit
NOTE:NOTE:
http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html
for more information on Activation Key Agreements.
ProLiant Essentials Performance Management Pack, Single-Server License
NOTE:
NOTE:
For use with a single server. Contains one license with a unique license
NOTE:NOTE: activation key and documentation.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
For use with a single server. Contains one license with a unique license
For use with multiple servers. This part number can be used to purchase
For use with signed and implemented Activation Key Agreements only.
389941-B21
371645-B21 372029-B21 371646-B21
371647-B21
378372-B21
391674-B21 391675-B21 391676-B21 390739-B21
375345-B21 375346-B21 375347-B21 372214-B21
372215-B21 372216-B21
372906-B21
372950-B21
372951-B21
306696-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 24
QuickSpecs
Options
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
ProLiant Essentials Performance Management Pack, 10-Server License
NOTE:
NOTE:
For use with up to 10 servers. Contains 10 licenses with one unique license
NOTE:NOTE: activation key and documentation.
ProLiant Essentials Performance Management Pack, Flexible-Quantity License
NOTE:
NOTE:
For use with multiple servers. This part number can be used to purchase
NOTE:NOTE: multiple licenses with a single activation key. The quantity ordered of this part number will be the quantity of licenses included in the kit in the form of a corresponding activation key. Use the same key to activate all licenses in the actual quantity ordered. For a given order, one kit will be delivered with activation key, and documentation.
ProLiant Essentials Performance Management Pack, Tracking license
NOTE:
NOTE:
NOTE: NOTE: Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement. NOTE:
NOTE:
NOTE:NOTE:
http://h18004.www1.hp.com/products/servers/proliantessentials/license/akalic.html
for more information on Activation Key Agreements.
Rapid Deployment Pack, 10 User, V1.x
NOTE:
NOTE:
NOTE: NOTE: Deployment Server. NOTE:
NOTE:
NOTE: NOTE: Deployment Pack licenses 281404-B21. NOTE:
NOTE:
NOTE: NOTE: NOTE:
NOTE:
NOTE: NOTE: Deployment Server. NOTE:
NOTE:
NOTE: NOTE: Deployment Pack licenses 281404-B21. NOTE:
NOTE:
NOTE: NOTE:
Rapid Deployment Pack, 1 User, V1.x
NOTE:
NOTE:
NOTE: NOTE: Server. NOTE:
NOTE:
NOTE: NOTE: Deployment Pack licenses 281404-B21. NOTE:
NOTE:
NOTE: NOTE: NOTE:
NOTE:
NOTE: NOTE: Server. NOTE:
NOTE:
NOTE: NOTE: Deployment Pack licenses 281404-B21. NOTE:
NOTE:
NOTE: NOTE:
Flexible Quantity License Kit License-Only - for use with a Master License Agreement ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning
Manager version 2.0)
NOTE:
NOTE:
NOTE:NOTE: following URL:
NOTE:
NOTE:
NOTE:NOTE: Value Packs. Refer to URL ProLiant Essentials Value Pack product QuickSpecs for more information.
For use with signed and implemented Activation Key Agreements only.
Nothing is delivered in conjunction with the purchase of this part number. Visit
This license allows 10 servers to be managed and deployed via the
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments. This license allows 10 servers to be managed and deployed via the
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments.
This license allows 1 server to be managed and deployed via the Deployment
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments. This license allows 1 server to be managed and deployed via the Deployment
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments.
For more information regarding ProLiant Essentials Software, please see the
http://hp.com/servers/proliantessentials
Flexible and volume quantity license kits are available for ProLiant Essentials
http://hp.com/servers/proliantessentials
.
or the various
374055-B21
306697-B21
306698-B21
269817-B21
267196-B21
302127-B21 302128-B21 303284-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 25
QuickSpecs
Options
Processor
Processor
ProcessorProcessor
Memory
Memory
MemoryMemory (SDRAM DIMMs)
Hard Drives
Hard Drives
Hard DrivesHard Drives
HP BL25p Opteron 2.2GHz-1M DC Processor Option Kit HP BL25p Opteron 2.0GHz-1M DC Processor Option Kit HP BL25p Opteron 1.8GHz-1M DC Processor Option Kit HP BL25p Opteron 2.6GHz-1M SC Processor Option Kit HP BL25p Opteron 2.4GHz-1M SC Processor Option Kit
4GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB) 2GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) 1GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot PlugUltra320 SCSI – Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
146.8-GB 15,000 rpm U320 Universal Hard Drive (1")
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
392440-B21 392442-B21 392444-B21 381588-B21 381587-B21
379300-B21 376639-B21 376638-B21
350964-B22 286716-B22 286714-B22 286778-B22 347708-B22 286776-B22
Storage Controllers
Storage Controllers
Storage ControllersStorage Controllers
ProLiant BL25/45p Fibre
ProLiant BL25/45p Fibre
ProLiant BL25/45p FibreProLiant BL25/45p Fibre Channel
Channel
ChannelChannel Adapter
Adapter
AdapterAdapter
128MB Battery Backed Write Cache Enabler Option Kit
NOTE:
NOTE:
Please see the following Controller QuickSpecs for Technical Specifications
NOTE:NOTE: such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/12030_na/12030_na.HTML
(Smart Array 6i)
Dual port Fibre Channel Adapter (2-Gb) for HP ProLiant BL25p server blade (shared with the HP ProLiant BL45p server blade)
NOTE:
NOTE:
When using this card, the Patch Panel 2, CGESM, or GbE2 Interconnect
NOTE:NOTE: Switch (with Storage Connectivity Kit) must be used to provide the Fibre Channel pass through. NOTE:
NOTE:
The BL30p/35p and BL20p dual-port Fibre Channel adapters are not
NOTE:NOTE: compatible with the HP ProLiant BL25p server blade.
346914-B21
381881-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 26
QuickSpecs
Options
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade Enclosures
Enclosures
EnclosuresEnclosures
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components and the HP BladeSystem Management Suite
NOTE:
NOTE:
NOTE: NOTE: backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM). NOTE:
NOTE:
The HP ProLiant BL25p server blade does not currently support PMP. Future
NOTE:NOTE: support is planned.
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (ProLiant Essentials Rapid Deployment Pack Trial)
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (8 ProLiant Essentials Rapid Deployment Licenses)
NOTE:
NOTE:
NOTE: NOTE: backplane components may be required depending on which HP ProLiant BL25p server blade model is selected. For additional information regarding Blade Enclosure Compatibility, please visit the following URL:
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)
NOTE:
NOTE:
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced
NOTE:NOTE: backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Includes a HP BladeSystem p-Class Server Blade Enclosure with enhanced
HP BladeSystem p-Class Enhanced Server Blade Enclosures with enhanced
http://www.hp.com/go/bladesystem/enclosure/compatibility
380625-B22
243564-B22
281404-B22
354100-B21
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Interconnects
p-Class Interconnects
p-Class Interconnectsp-Class Interconnects
ProLiant BL p-Class RJ-45 Patch Panel 2 with Fibre pass-through (pair) (required for FC connectivity)
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class RJ-45 Patch Panel (pair)
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules)
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules)
NOTE:
NOTE:
NOTE:NOTE:
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only
NOTE:
NOTE:
NOTE: NOTE:
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules
NOTE:
NOTE:
NOTE: NOTE:
Cisco RJ-45 10/100/1000 T/TX/T SFP Module Cisco Fiber SX SFP Module ProLiant BL p-Class Storage Connectivity Kit (with pair of OctalFC Interconnect
Modules and two Fibre Channel signal conditioning cards)
Only one interconnect kit required per server blade enclosure.
Only one interconnect kit required per server blade enclosure.
Only one interconnect kit required per server blade enclosure.
Only one interconnect kit required per server blade enclosure.
Two CGESM interconnect kits required per server blade enclosure.
Two CGESM interconnect kits required per server blade enclosure.
306465-B21
230766-B21
283192-B21
283193-B21
378926-B21
378927-B21
378928-B21 378929-B21 321745-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 27
QuickSpecs
Options
NOTE:
NOTE:
NOTE: NOTE: CGESM or GbE2 Interconnect Switch. NOTE:
NOTE:
NOTE: NOTE: NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules)
NOTE:
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:NOTE: NOTE:
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
NOTE:NOTE: recommended that a patch panel or GbE2 Interconnect Switch option be used if server NIC speeds to 1000 Mbps are required. NOTE:
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels
NOTE:NOTE: on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules)
NOTE:
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:NOTE: NOTE:
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
NOTE:NOTE: recommended that a patch panel option be used if server NIC speeds to 1000 Mbps are required. NOTE:
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels
NOTE:NOTE: on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Required for BL20P G3 Fibre Channel signal pass through when using the
Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit.
249655-B21
279720-B21
HP BladeSystem p-Class
HP BladeSystem p-Class
HP BladeSystem p-ClassHP BladeSystem p-Class Power Options
Power Options
Power OptionsPower Options
NOTE:
NOTE:
NOTE: NOTE:
http://h30099.www3.hp.com/configurator/powercalcs.asp
Single Phase 3U Power Enclosure with 4 power supplies (Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)
3 Phase 3U Power Enclosure with 6 power supplies (3 Phase 3U Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit)
Single Phase 3U Power Enclosure (empty) (Holds up to 4 power supplies; power supplies are not included in this kit)
3 Phase 3U Power Enclosure (empty) (Holds up to 6 power supplies; power supplies are not included in this kit)
Single 3U Power Supply 1U Power Enclosure with six power supplies 1U Power Enclosure with two power supplies Single 1U Power Supply Facility DC Power Connection
Use p-Class sizing tool to help determine power configuration:
239162-001
230769-001
231710-001
231709-001
239161-B21 378284-B21 380314-B21 380312-B21 240563-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 28
QuickSpecs
Options
Power Distribution (only
Power Distribution (only
Power Distribution (onlyPower Distribution (only required with 3U power
required with 3U power
required with 3U powerrequired with 3U power enclosures)
enclosures)
enclosures)enclosures)
SAN Switches
SAN Switches
SAN SwitchesSAN Switches
HP BladeSystem p-Class Scalable Bus Bar HP BladeSystem p-Class Mini Bus Bar HP BladeSystem p-Class Bus Power Box Dual Power Input Kit for Mini Bus Bar HP Modular Distribution Unit 40 Amp HP Modular Distribution Unit 24 Amp
NOTE:
NOTE:
The Modular Distribution Unit Kits excludes the extension bars as they are not
NOTE:NOTE: required with the HP BladeSystem p-class 1U power enclosure.
HP BladeSystem Power Extension Kit
NOTE:
NOTE:
This kit is specifically for HP BladeSystem p-Class customers who want to
NOTE:NOTE: upgrade their standard server blade enclosures to enhanced server blade enclosures and would like to install an additional, redundant 3U power enclosure above the server blade enclosures rather than below them. The option kit consists of two extension cable assemblies - one for each side (A and B).
Brocade 4GB SAN Switch, Base Brocade 4GB SAN Switch, full fabric Brocade 4GB SAN Switch, power pack McDATA 4Gb SAN Switch
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
240560-B21 240559-B21 240562-B21
364565-B21 252663-D75 252663-D74
381686-B21
A7533A A7534A A7535A A8001A
Other Options
Other Options
Other OptionsOther Options
Tape Libraries
Tape Libraries
Tape LibrariesTape Libraries
HP BladeSystem p-Class Diagnostic Station
NOTE:
NOTE:
The Diagnostic Station allows access to the ProLiant BL20p server blade and
NOTE:NOTE: the BL p-Class interconnect switch outside of the server enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed.
HP BladeSystem p-Class Power Enclosure Shipping Bracket Option Kit
NOTE:
NOTE:
NOTE: NOTE:
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape LibraryHP StorageWorks MSL6000 Tape Library Ultrium 960 technology
Ultrium 960 technology
Ultrium 960 technologyUltrium 960 technology MSL6030, 1 drive, 30 slots, Ultrium 960 AD606A MSL6030, 2 drive, 30 slots, Ultrium 960 AD607A MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router MSL6060, 2 drive, 60 slots, Ultrium 960 AD610A MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router SDLT 600 technology
SDLT 600 technology
SDLT 600 technologySDLT 600 technology MSL6026, 1 drive, 26 slots, SDLT 600 MSL6026, 2 drive, 26 slots, SDLT 600 MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router MSL6052, 2 drive, 52 slots, SDLT 600 MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router Ultrium 460 technology
Ultrium 460 technology
Ultrium 460 technologyUltrium 460 technology
230743-B21
365044-B21
AD608A AD609A
AD611A
AD582A AD583A AD584A AD585A AD587A AD588A
DA - 12160 North America — Version 7 — June 27, 2005
Page 29
QuickSpecs
Options
MSL6030, 1 drive, 30 slots, Ultrium 460 AD598A MSL6030, 2 drive, 30 slots, Ultrium 460 AD599A MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router
NOTE:
NOTE:
NOTE: NOTE:
http://www.hp.com/go/automation
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks MSL5026S2 Tape Library
HP StorageWorks MSL5026S2 Tape Library
HP StorageWorks MSL5026S2 Tape LibraryHP StorageWorks MSL5026S2 Tape Library MSL5026S2, 1 drive, 26 slots, SDLT 320, RM MSL5026S2, 2 drive, 26 slots, SDLT 320, RM MSL5026S2, 1 drive, 26 slots, SDLT 320, RM with embedded FC router MSL5026S2, 2 drive, 26 slots, SDLT 320, RM with embedded FC router
NOTE:
NOTE:
Please reference the MSL5026S2 Tape Library QuickSpecs at
NOTE:NOTE:
http://www.hp.com/go/automation
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks MSL5052S2 Tape Library
HP StorageWorks MSL5052S2 Tape Library
HP StorageWorks MSL5052S2 Tape LibraryHP StorageWorks MSL5052S2 Tape Library MSL5052S2, 2 drive, 52 slots, SDLT 320, RM MSL5052S2, 2 drive, 52 slots, SDLT 320, RM with embedded FC router
NOTE:
NOTE:
NOTE: NOTE:
http://www.hp.com/go/automation
complete solution; reference current compatibility information at
http:/www.hp.com/go/ebs
HP StorageWorks ESL E-Series Tape Libraries
HP StorageWorks ESL E-Series Tape Libraries
HP StorageWorks ESL E-Series Tape LibrariesHP StorageWorks ESL E-Series Tape Libraries ESL Extended 712e Tape Library, 0 drive, 712 LTO slots ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots ESL Extended 322e Tape Library, 0 drive, 322 LTO slots ESL Extended 286e Tape Library, 0 drive, 286 SDLT slots ESL E-Series Ultrium 960 drive kit ESL E-Series Ultrium 460 drive kit ESL E-Series Ultrium 460-FC drive kit ESL E-Series SDLT 320 drive kit ESL E-Series e2400-FC 2G Interface Controller
NOTE:
NOTE:
Please reference the ESL E-Series Tape Libraries QuickSpecs at
NOTE:NOTE:
http://www.hp.com/go/automation
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Please reference the MSL6000 Tape Library QuickSpecs at
for additional information needed to create a
for additional information needed to create a
Please reference the MSL5052S2 Tape Library QuickSpecs at
for additional information needed to create a
for additional information needed to create a
.
AD600A AD601A AD604A
293472-B22
293472-B23
293472-B24
293472-B25
293474-B21
293474-B24
AA934B AA935B AA939B AA940B
AD595A
AA937A AA941A AA936A AA928A
DA - 12160 North America — Version 7 — June 27, 2005
Page 30
QuickSpecs
Options
Ultra Density Optical
Ultra Density Optical
Ultra Density OpticalUltra Density Optical Jukeboxes
Jukeboxes
JukeboxesJukeboxes
Magneto-Optical
Magneto-Optical
Magneto-OpticalMagneto-Optical Jukeboxes
Jukeboxes
JukeboxesJukeboxes
1000ux, 2 drive, 32 slot jukebox 1900ux, 4 drive, 64 slot jukebox 1900ux, 4 mixed drive, 64 slot jukebox 2300ux, 2 drive, 76 slot jukebox 3800ux, 4 drive, 128 slot jukebox 3800ux, 6 drive, 128 slot jukebox 7100ux, 4 drive, 238 slot jukebox 7100ux, 6 drive, 238 slot jukebox 7100ux, 10 drive, 238 slot jukebox 7100ux, 6 mixed drive, 238 slot jukebox
NOTE:
NOTE:
NOTE: NOTE:
http://www.hp.com/go/optical
complete solution.
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical JukeboxesHP StorageWorks 9.1 GB Mid-range Optical Jukeboxes 300mx, 2 drive, 32 slot jukebox 600mx, 4 drive, 64 slot jukebox
700mx, 2 drive, 76 slot jukebox
NOTE:
NOTE:
Please reference the Magneto-Optical Jukebox data sheets at
NOTE:NOTE:
http://www.hp.com/go/optical
complete solution
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical JukeboxesHP StorageWorks 9.1 GB High-end Optical Jukeboxes 1200mx, 4 drive, up to 128 slots 1200mx, 6 drive, up to 128 slots 2200mx, 4 drive, up to 238 slots 2200mx, 6 drive, up to 238 slots 2200mx, 10 drive, up to 238 slots
NOTE:
NOTE:
Please reference the Magneto-Optical Jukebox data sheets at
NOTE:NOTE:
http://www.hp.com/go/optical
complete solution.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Please reference the Ultra Density Optical Jukebox QuickSpecs at
for additional information needed to create a
for additional information needed to create a
for additional information needed to create a
AA965A AA966A AA968A AA967A AA969A AA970A AA973A AA971A AA972A AA974A
C1150M C1160M
C1170M
C1104M C1105M C1111M C1107M C1110M
DA - 12160 North America — Version 7 — June 27, 2005
Page 31
QuickSpecs
Options
HP StorageWorks
HP StorageWorks
HP StorageWorksHP StorageWorks Modular Smart Array
Modular Smart Array
Modular Smart ArrayModular Smart Array 1000
1000
10001000
HP StorageWorks
HP StorageWorks
HP StorageWorksHP StorageWorks Modular Smart Array
Modular Smart Array
Modular Smart ArrayModular Smart Array 1500
1500
15001500
Cluster Options
Cluster Options
Cluster OptionsCluster Options
HP StorageWorks Modular Smart Array 1000 Modular Smart Array 1000 Controller Modular Smart Array Fibre Channel I/O Module Modular Smart Array hub 2/3 HP StorageWorks Modular Smart Array 1000
NOTE:
NOTE:
Please see the StorageWorks Modular Smart Array 1000 QuickSpecs for
NOTE:NOTE: additional options and configuration information at:
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
HP StorageWorks Modular Smart Array 1500
NOTE:
NOTE:
NOTE: NOTE: additional options and configuration information at:
http://h18000.www1.hp.com/products/quickspecs/11945_na/11945_na.HTML
HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and Red Hat EL 3 (single license version)
HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and Red Hat EL 3 (2 node license cluster kit).
NOTE:
NOTE:
NOTE: NOTE: please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Please see the StorageWorks Modular Smart Array 1500 QuickSpecs for
For additional information regarding the HP Serviceguard for Linux License,
201723-B22
218231-B22
218960-B21
286763-B21
201723-B22
AA986A
307754-B26
305199-B26
USB Options
USB Options
USB OptionsUSB Options
HP Rack 5000 Series
HP Rack 5000 Series
HP Rack 5000 SeriesHP Rack 5000 Series (Graphite Metallic)
Rack Options for Rack
Rack Options for Rack
Rack Options for RackRack Options for Rack 5000 Series
5000 Series
5000 Series5000 Series
USB 1.44-MB External Diskette Drive (Carbonite) USB 2-Button Optical Mouse (Carbonite) USB Optical Scroll Mouse (Carbonite) 256MB HP Drive Key II (USB 2.0)
HP 5642 Rack - Unassembled
Stabilizer Kit for 5642 Rack (Graphite Carbon)
NOTE:
NOTE:
NOTE: NOTE:
Baying Kit for 5642 Rack (Graphite Carbon)
NOTE:
NOTE:
NOTE: NOTE:
The stabilizing kit is used to prevent rack from tipping over.
The baying kit is used to join two or more HP 5642 racks.
DC141B DC172B DD441B
PH657A
358254-B21
374493-B21
374499-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 32
QuickSpecs
Options
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Rack 10000 Series
Rack 10000 Series
Rack 10000 SeriesRack 10000 Series (Graphite Metallic)
Rack, HP Infrastructure 42U (HV) Rack, HP Infrastructure 42U (LV) HP Rack 10842 (42U) - Pallet HP Rack 10842 (42U) - Shock Pallet HP S10614 (14U) Rack Cabinet - Shock Pallet HP Rack 10647 (47U) Cabinet - Pallet HP Rack 10647 (47U) Cabinet - Crated HP Rack 10642 (42U) Cabinet - Pallet HP Rack 10642 (42U) Cabinet - Shock Pallet HP Rack 10642 (42U) Cabinet - Crated HP Rack 10636 (36U) Cabinet - Pallet HP Rack 10636 (36U) Cabinet - Shock Pallet HP Rack 10636 (36U) Cabinet - Crate HP Rack 10622 (22U) Cabinet - Pallet HP Rack 10622 (22U) Cabinet - Shock Pallet HP Rack 10622 (22U) Cabinet - Crated
NOTE:
NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck
NOTE:NOTE:
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE:
NOTE:
Please see the Rack 10000 QuickSpecs for Technical Specifications such as
NOTE:NOTE: height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML
NOTE:
NOTE:
For additional information regarding Rack Cabinets, please see the following
NOTE:NOTE: URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-
options/index.html
379005-001
379006-001
257415-B21
257415-B22
292302-B22
245160-B21
245160-B23
245161-B21
245161-B22
245161-B23
245162-B21
245162-B22
245162-B23
245163-B21
245163-B22
245163-B23
Rack Options for HP
Rack Options for HP
Rack Options for HPRack Options for HP Rack 10000 Series
Rack 10000 Series
Rack 10000 SeriesRack 10000 Series
HP Light kit for 10000 series rack HP Plinth kit for 10000 series rack 42U Side Panel – Graphite Metallic 36U Side Panel – Graphite Metallic 47U Side Panel – Graphite Metallic
NOTE:
NOTE: For additional information regarding Rack Options, please see the following
NOTE:NOTE: URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-
options/index.html
TFT5600 Rack Keyboard Monitor TFT7210R Rack Mounted 17" Monitor
NOTE:
NOTE:
For a complete list of Monitors please view the following URL:
NOTE:NOTE:
http://h18004.www1.hp.com/products/monitors/
1U Rack Keyboard & Drawer (Carbon)
NOTE:
NOTE:
NOTE: NOTE: URL:
options/index.html
For additional information regarding Rack Options, please see the following
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-
DA - 12160 North America — Version 7 — June 27, 2005
.
.
361589-B21
251960-B21
246099-B21
246102-B21
255486-B21
221546-001
348373-B21
257054-001
Page 33
QuickSpecs
Options
HP KVM Switch Options
HP KVM Switch Options
HP KVM Switch OptionsHP KVM Switch Options
Rack Options for Telco
Rack Options for Telco
Rack Options for TelcoRack Options for Telco Racks
Racks
RacksRacks
IP Console Switch Box (KVM/IP), 1 x 1 x 16 IP Console Switch Box (KVM/IP) , 3 x 1 x 16 Serial Interface adapter - 1 Pack with power supply Interface adapter - USB 1.0 (single pack) CAT5e Cable 3', 4 pack CAT5e Cable 6', 8 pack CAT5e Cable 12', 8 pack CAT5e Cable 20', 4 pack CAT5e Cable 40', 1 pack
NOTE:
NOTE:
NOTE: NOTE: see the following URL:
http://h18004.www1.hp.com/products/servers/proliantstorage/rack­options/list.html/#console
ProLiant BL p-Class Bus Bar Telco Rack Kit ProLiant BL p-Class Enclosure Telco Rack Kit
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
For additional information regarding HP KVM Switches and options, please
262585-B21
262586-B21
373035-B21
336047-B21
263474-B21
263474-B22
263474-B23
263474-B24
263474-B25
245249-B21
266076-B21
Service and Support
Service and Support
Service and SupportService and Support Offerings
Offerings
Offerings Offerings Services)
(HP Care Pack
NOTE:
NOTE: The HP Care Pack services for ProLiant BL p-Class server blades, cover the
NOTE:NOTE: server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution.
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site ServiceHardware Services On-site Service Next Business Day On-site Service, 5-Day x 9-Hour Coverage,
3 Years Next Business Day On-site Service, 5-Day x 9-Hour Coverage,
3 Years, Electronic 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
UA203A
UA203E
UA204A
UA204E
UA205A
UA205E
UA206A
UA206E
DA - 12160 North America — Version 7 — June 27, 2005
Page 34
QuickSpecs
Options
Installation & Start-up Services
Installation & Start-up Services
Installation & Start-up ServicesInstallation & Start-up Services ProLiant BL p-Class Blade Server Hardware Installation
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
UA219A
ProLiant BL p-Class Blade Server Hardware Installation, Electronic ProLiant BL p-Class Enclosure and Server Blade Hardware Installation ProLiant BL p-Class Enclosure and Server Blade Hardware Installation, Electronic Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment Pack
on a Customer supplied server designated as a Deployment Server. Includes the deployment of a single server. This new server will be deployed using either one of the pre-configured scripts or an image. In addition, the service will provide for the capture and storage of the configuration of the newly deployed server and orientation on product usage. To be delivered during standard office ours, standard office days.
Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment Pack on a Customer supplied server designated as a Deployment Server. Includes the deployment of a single server. This new server will be deployed using either one of the pre-configured scripts or an image. In addition, the service will provide for the capture and storage of the configuration of the newly deployed server and orientation on product usage. To be delivered during standard office ours, standard office days. Electronic.
Provides for the Installation and Start-up of Rapid Deployment Pack Implementation of Rapid Deployment Pack (Basic)
Provides for the Installation and Start-up of Rapid Deployment Pack Implementation of Rapid Deployment Pack (Basic) (Electronic)
Provides for the Installation and Start-up of System Insight Manager Provides for the Installation and Start-up of System Insight Manager (Electronic) Provides for the Installation and Start-up of System Insight Manager Agents Provides for the Installation and Start-up of System Insight Manager (Electronic)
NOTE:
NOTE:
For more information, customer/resellers can contact
NOTE:NOTE:
http://www.hp.com/hps/carepack/services/
Software Operating Environment Care Packs
Software Operating Environment Care Packs
Software Operating Environment Care PacksSoftware Operating Environment Care Packs Microsoft Software Operating Environment Software Telephone 9x5 - 3 incident Microsoft Software Operating Environment Software Telephone 9x5 - 3 incident
(Electronic) Red Hat Software Operating Environment Software Telephone 9x5 - 10 incident Red Hat Software Operating Environment Software Telephone 9x5 - 10 incident
(Electronic) SUSE Software Operating Environment Software Telephone 9x5 - 3 incident SUSE Software Operating Environment Software Telephone 9x5 - 3 incident
(Electronic) ProLiant Essentials Operating Environment, - 5 Day, 8x5,1 year, 3 incident ProLiant Essentials Operating Environment, - 5 Day, 8x5,1 year, 3 incident (Electronic)
UA219E
U4971A
U4971E
U5683A
U5683E
UA042A
UA042E
UA041A
UA041E
UA040A
UA040E
U8169A
U8169E
U3402A
U3402E
U9615A
U9615E
U8222A
U8222E
DA - 12160 North America — Version 7 — June 27, 2005
Page 35
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade

Memory

HP ProLiant BL25p Server Blade (2P Models)
HP ProLiant BL25p Server Blade (2P Models)
HP ProLiant BL25p Server Blade (2P Models)HP ProLiant BL25p Server Blade (2P Models) Standard Memory
Standard Memory
Standard MemoryStandard Memory 2048-MB PC3200 Registered DDR SDRAM DIMM installed (4 x 512MB SDRAM DIMM)
Standard Memory Plus Optional Memory
Standard Memory Plus Optional Memory
Standard Memory Plus Optional MemoryStandard Memory Plus Optional Memory Up to 10240-MB of DDR SDRAM DIMM memory is available with the installation of optional DDR SDRAM DIMM memory expansion kits.
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional MemoryStandard Memory Replaced with Optional Memory Up to 16384-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional SDRAM DDR DIMM memory expansion kits.
Memory
Memory
MemoryMemory
1111 2222 3333 4444 5555 6666 7777 8888
Standard
Standard
StandardStandard Optional
Optional
OptionalOptional Maximum
Maximum
MaximumMaximum
2048 MB
2048 MB
2048 MB2048 MB 10240 MB
10240 MB
10240 MB10240 MB 16384 MB
16384 MB
16384 MB16384 MB
512 MB 512 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB
Empty Empty 512 MB 512 MB
Following are memory options available from HP:
4096MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB) 2048MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) 1024MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
Slot
Slot
SlotSlot
512 MB 512 MB 2048 MB 2048 MB
Empty Empty 512 MB 512 MB
379300-B21
376639-B21
376638-B21
HP ProLiant BL25p Server Blade (1P Model)
HP ProLiant BL25p Server Blade (1P Model)
HP ProLiant BL25p Server Blade (1P Model)HP ProLiant BL25p Server Blade (1P Model) Standard Memory
Standard Memory
Standard MemoryStandard Memory 1024-MB PC3200 400MHz Registered DDR SDRAM DIMM installed
Standard Memory Plus Optional Memory
Standard Memory Plus Optional Memory
Standard Memory Plus Optional MemoryStandard Memory Plus Optional Memory Up to 5120-MB of DDR SDRAM DIMM memory is available with the installation of optional DDR SDRAM DIMM memory expansion kits.
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional MemoryStandard Memory Replaced with Optional Memory Up to 8192-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional DDR SDRAM DIMM memory expansion kits.
Memory
Memory
MemoryMemory
Standard
Standard
StandardStandard Optional
Optional
OptionalOptional Maximum
Maximum
MaximumMaximum
1024 MB
1024 MB
1024 MB1024 MB 5120 MB
5120 MB
5120 MB5120 MB 8192 MB
8192 MB
8192 MB8192 MB
1111 2222 3333 4444 5555 6666 7777 8888 512 MB 512 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB 2048 MB
Empty Empty Empty Empty Empty Empty 512 MB 512 MB
Slot
Slot
SlotSlot
Empty Empty Empty Empty Empty Empty Empty Empty
Following are memory options available from HP:
4096MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB) 2048MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) 1024MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
379300-B21 376639-B21 376638-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 36
QuickSpecs

Technical Specifications

HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade Enclosure
Enclosure
EnclosureEnclosure
Dimensions
Dimensions
DimensionsDimensions
Input Specifications
Input Specifications
Input SpecificationsInput Specifications
Individual Server Blade
Individual Server Blade
Individual Server BladeIndividual Server Blade Bay Ratings
Bay Ratings
Bay RatingsBay Ratings
Temperature Range
Temperature Range
Temperature RangeTemperature Range
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Height Width Depth Rated input voltage Rated input current Rated input Power Rated input voltage Rated input current Rated input Power Operating Non-Operating Operating Non-Operating Operating Non-Operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
10.5 in (26.67 cm)
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC
62.5 A at -48 VDC 3000 W
-43 VDC to -53 VDC
6.25 A at -48 VDC 300 W 50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Nominal -48 VDC
Nominal -48 VDC
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade Enclosure with enhanced
Enclosure with enhanced
Enclosure with enhancedEnclosure with enhanced backplane components
backplane components
backplane componentsbackplane components
Dimensions
Dimensions
DimensionsDimensions
Input Specifications
Input Specifications
Input SpecificationsInput Specifications
Individual Server Blade
Individual Server Blade
Individual Server BladeIndividual Server Blade Bay Ratings
Bay Ratings
Bay RatingsBay Ratings
Temperature Range
Temperature Range
Temperature RangeTemperature Range
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Height Width Depth Rated input voltage Rated input current Rated input Power Rated input voltage Rated input current Rated input Power Operating Non-Operating Operating Non-Operating Operating Non-Operating
10.5 in (26.67 cm)
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC 125 A at -48 VDC 6000 W
-43 VDC to -53 VDC
14.6 A at -48 VDC 700 W 50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Nominal -48 VDC
Nominal -48 VDC
DA - 12160 North America — Version 7 — June 27, 2005
Page 37
QuickSpecs
Technical Specifications
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for RJ-45
Specifications for RJ-45
Specifications for RJ-45Specifications for RJ-45 Patch Panel 2 with Fiber
Patch Panel 2 with Fiber
Patch Panel 2 with FiberPatch Panel 2 with Fiber Channel pass through
Channel pass through
Channel pass throughChannel pass through
Dimensions
Dimensions
DimensionsDimensions
Capability
Capability
CapabilityCapability Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Fiber Channel SAN
Fiber Channel SAN
Fiber Channel SANFiber Channel SAN Connector
Connector
ConnectorConnector
Cable Support
Cable Support
Cable SupportCable Support
EMI
EMI
EMIEMI
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Height Width Depth IEEE 802.2, 802.3, 802.3u 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (full-duplex) Velio VC1070 re-timer Network Fiber Channel SAN 10 Base-TX
100 Base-TX 1000 Base-TX Fiber Channel FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps Auto-rate negotiate between 2G and 1G RJ-45 in the back. Pluggable SFP optical slot in the front. Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m) Category 5 UTP (2 pair); up to 328 ft/100 m Category 5E (4 pair); up to 328 ft (100 m) SFP optical cable
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for RJ-45
Specifications for RJ-45
Specifications for RJ-45Specifications for RJ-45 Patch Panel
Patch Panel
Patch PanelPatch Panel
Dimensions
Dimensions
DimensionsDimensions
Capability
Capability
CapabilityCapability Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Connector
Connector
ConnectorConnector Cable Support
Cable Support
Cable SupportCable Support
Power Requirements
Power Requirements
Power RequirementsPower Requirements Temperature Range
Temperature Range
Temperature RangeTemperature Range
DA - 12160 North America — Version 7 — June 27, 2005
Height Width Depth IEEE 802.2, 802.3, 802.3u 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (full-duplex) Network 10 Base-TX
100 Base-TX 1000 Base-TX 200 mA at + 5V DC; 500 mA at -48V Operating Non-operating
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 1000 Mbps RJ-45 in the back Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m) Category 5 UTP (2 pair); up to 328 ft (100 m) Category 5E (4 pair); up to 328 ft (100 m)
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
Page 38
QuickSpecs
Technical Specifications
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for ProLiant
Specifications for ProLiant
Specifications for ProLiantSpecifications for ProLiant BL p-Class GbE
BL p-Class GbE
BL p-Class GbEBL p-Class GbE Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses
Forwarding Table
Forwarding Table
Forwarding TableForwarding Table Age Time
Age Time
Age TimeAge Time Memory
Memory
MemoryMemory Compliance
Compliance
ComplianceCompliance
Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Connector
Connector
ConnectorConnector
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Operating Non-operating Operating Non-operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Height Width Depth
11.5 lb/5.2 kg per interconnect switch
9.6 Gbps external port bandwidth per server blade enclosure (full duplex) Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per
gigabit port, (64-byte packets) Non-blocking, full-wire speed for all connections Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 8,191 per interconnect switch; MAC address based filtering and MAC
address packet priority configuring Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D,
802.1p, 802.3ac, 802.3ad (Static), and 802.1Q SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC
2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC
2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps
IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC
854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC
2131) and ZModem, 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half and
full-duplex) 1000 Base-SX (full-duplex) 12 RJ-45, 2 DB-9 (C-GbE Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit)
20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps 20 Mbps 100 Mbps 200 Mbps 2000 Mbps
2000 Mbps
DA - 12160 North America — Version 7 — June 27, 2005
Page 39
QuickSpecs
Technical Specifications
Cable Support
Cable Support
Cable SupportCable Support
Safety
Safety
SafetySafety
Power Requirements
Power Requirements
Power RequirementsPower Requirements Temperature Range
Temperature Range
Temperature RangeTemperature Range
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A UL/CUL Listed Accessory CE
-48VDC: 1050 mA, 50 W maximum (per interconnect switch) Operating Non-operating Operating Non-operating Operating Non-operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for GbE2
Specifications for GbE2
Specifications for GbE2Specifications for GbE2 Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses Forwarding Table
Forwarding Table
Forwarding TableForwarding Table Age Time
Age Time
Age TimeAge Time Memory
Memory
MemoryMemory Compliance
Compliance
ComplianceCompliance
Height Width Depth
12.0 lb/5.4 kg per interconnect switch 24 Gbps External port bandwidth per server blade enclosure (full duplex) Forwarding rate 1.5 million pps per gigabit port (64-byte packets) Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 2,048 per interconnect switch Maximum age: 1 to 65535 seconds; default: 300 seconds
128MB Main, 32MB flash and 2MB packet buffer per interconnect switch IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D,
802.3ac, 802.3ad (Static), and 802.1Q SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface
Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps
RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
DA - 12160 North America — Version 7 — June 27, 2005
Page 40
QuickSpecs
Technical Specifications
Network Transfer
Network Transfer
Network TransferNetwork Transfer Rate
Rate
RateRate
Connector
Connector
ConnectorConnector
EMI
EMI
EMIEMI
Safety
Safety
SafetySafety
Power
Power
PowerPower Requirements
Requirements
RequirementsRequirements
Temperature
Temperature
TemperatureTemperature Range
Range
RangeRange Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb
Wet Bulb
Wet BulbWet Bulb Temperature
Temperature
TemperatureTemperature
NOTE:
NOTE:
NOTE: NOTE: sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half and
full-duplex) 1000 Base-SX (full-duplex) 12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit) FCC Class A ICES-003 Class A AS/NZS 3548 Class A VCCI Class A UL/CUL Listed Accessory CE 48VDC: 2040 mA, 98 W maximum (per interconnect switch without Storage
Connectivity Kit) 48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage Connectivity Kit)
Operating Non-operating Operating Non-operating Operating Non-operating
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
10 Mbps 20 Mbps 100 Mbps 200 Mbps 2000 Mbps
2000 Mbps
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C) 20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for CGESM
Specifications for CGESM
Specifications for CGESMSpecifications for CGESM Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses Memory
Memory
MemoryMemory
DA - 12160 North America — Version 7 — June 27, 2005
Height Width Depth
11.5 lb/5.2 kg per interconnect switch 28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum
Forwarding Rate (64 Byte Packets) 9018Bytes Jumbo Frames MTU Non-blocking architecture. Wire Speed Performance on all ports Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support Store and forward 8000 MAC/physical address Table Size 128MB DRAM Memory. 16MB Flash Memory
10.405 in (26.43 cm)
1.6 in (4.06 cm) 28 in (71.12 cm)
Page 41
QuickSpecs
Technical Specifications
Compliance
Compliance
ComplianceCompliance
Network Transfer
Network Transfer
Network TransferNetwork Transfer Rate
Rate
RateRate
Connector
Connector
ConnectorConnector EMI
EMI
EMIEMI
Safety
Safety
SafetySafety
Power
Power
PowerPower Requirements
Requirements
RequirementsRequirements Temperature
Temperature
TemperatureTemperature Range
Range
RangeRange
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE
802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 (RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-
MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION­MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS­MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE­RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH­MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO­SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB, SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB, UDP-MIB
1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX 10 Base-T (half-duplex) 10 Base-T (full-duplex) 100 Base-TX (half-duplex) 100 Base-TX (full-duplex) 1000 Base-TX (half and
full-duplex) 1000 Base-SX (full-duplex) 4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9 FCC Part 15 Class A EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24) CNS 13438 Class A MIC CD MIC
AS/NZS 3548 Class A CE VCCI Class A UL to UL 60950, Third Edition
C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition TUV/GS to EN 60950:2000 CB to IEC 60950 with all country deviations NOM to NOM-019-SCFI
CE Marking
-48VDC: 1050 mA, 125 W maximum (per interconnect switch)
Operating Non-operating
10 Mbps 20 Mbps 100 Mbps 200 Mbps 2000 Mbps
2000 Mbps
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
DA - 12160 North America — Version 7 — June 27, 2005
Page 42
QuickSpecs
Technical Specifications
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity (non-condensing)
(non-condensing)
(non-condensing)(non-condensing) Wet Bulb
Wet Bulb
Wet BulbWet Bulb Temperature
Temperature
TemperatureTemperature
NOTE:
NOTE:
NOTE: NOTE: sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for
Specifications for
Specifications forSpecifications for Power Enclosures
Power Enclosures
Power EnclosuresPower Enclosures
Dimensions
Dimensions
DimensionsDimensions
Weights
Weights
WeightsWeights
Input Requirements
Input Requirements
Input RequirementsInput Requirements
Output Voltage
Output Voltage
Output VoltageOutput Voltage Specifications
Specifications
SpecificationsSpecifications
Ambient Temperature
Ambient Temperature
Ambient TemperatureAmbient Temperature Range
Range (See
RangeRange
Relative humidity,
Relative humidity,
Relative humidity,Relative humidity, non-condensing
non-condensing
non-condensingnon-condensing
(See
NOTE
NOTE
NOTENOTE
Wet Bulb
Wet Bulb
Wet BulbWet Bulb Temperature
Temperature
TemperatureTemperature
NOTE:
NOTE:
NOTE: NOTE: direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Operating Non-operating Operating Non-operating
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
Height Width Depth No Hot-Plug
Power Supplies All Hot-Plug
Power Supplies Rated input voltage
Rated input frequency Rated input current
per side Rated input power
per side Power cord
Rated output voltage Rated output current Rated output power Nominal power Operating
NOTE
NOTE
)
NOTENOTE
Shipping
Operating
)
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Non-operating
Operating Non-operating
20% to 80% 5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Single-Phase Model
Single-Phase Model
Single-Phase ModelSingle-Phase Model
5.25 in (13.34 cm) 5.25 in (13.34 cm)
27.15 in (68.96 cm) 27.15 in (68.96 cm)
17.60 in (44.7 cm) 17.60 in (44.7 cm)
47.5 lb (21.55 kg) 47.5 lb (21.55 kg)
99.5 lb (45.13 kg)
200 VAC to 240 VAC 200 VAC to 240 VAC
50 Hz to 60 Hz 50 Hz to 60 Hz 24A
5760 W 9976 W
1 NEMA L6-30P per side
-48.8 VDC to -54 VDC -48.8 VDC to -54 VDC 99A 4298 W 8310 W 4158 W at 208 VAC 7202 W at 208 VAC 50° to 95° F
(10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80% 20% to 80%
5% to 95% 5% to 95%
82.4° F (28° C) 82.4° F (28° C)
101.7° F (38.7° C) 101.7° F (38.7° C)
Three-Phase Model
Three-Phase Model
Three-Phase ModelThree-Phase Model
125.5 lb (56.93 kg)
line to line
24A per phase
1 NEMA L15-30 per side
170A
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
DA - 12160 North America — Version 7 — June 27, 2005
Page 43
QuickSpecs
Technical Specifications
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for
Specifications for
Specifications forSpecifications for Power Distribution
Power Distribution
Power DistributionPower Distribution Devices
Devices
DevicesDevices
Power
Power
PowerPower Enclosures or facility DC
Enclosures or facility DC
Enclosures or facility DCEnclosures or facility DC feeds Supported
feeds Supported
feeds Supportedfeeds Supported (3U each)
Server blade enclosures
Server blade enclosures
Server blade enclosuresServer blade enclosures supported
supported
supportedsupported (6U each)
Total rack height of
Total rack height of
Total rack height ofTotal rack height of supported enclosures
supported enclosures
supported enclosuressupported enclosures Dimensions
Dimensions
DimensionsDimensions Height Width Depth Weight
Weight
WeightWeight Rated Operating
Rated Operating
Rated OperatingRated Operating Voltage
Voltage
VoltageVoltage Max Total Power
Max Total Power
Max Total PowerMax Total Power Supported
Supported
SupportedSupported Total Max Input Current
Total Max Input Current
Total Max Input CurrentTotal Max Input Current At Minimum Voltage
At Minimum Voltage
At Minimum VoltageAt Minimum Voltage
Total Max Input Current
Total Max Input Current
Total Max Input CurrentTotal Max Input Current At Nominal Voltage
At Nominal Voltage
At Nominal VoltageAt Nominal Voltage
Max Current Per Power
Max Current Per Power
Max Current Per PowerMax Current Per Power Feed
Feed
FeedFeed Max Local Ambient
Max Local Ambient
Max Local AmbientMax Local Ambient Temperature
Temperature
TemperatureTemperature
NOTE:
NOTE:
NOTE: NOTE:
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Power Bus Box
Power Bus Box
Power Bus BoxPower Bus Box 1 1 2
1 3 5
9U
5.1 in (12.95 cm)
3.6 in (9.14 cm) each
3.25 in (8.26 cm)
3.62 lb (1.64 kg)
-43.2 VDC to -54 VDC -43.2 VDC to -54 VDC -43.2 VDC to -54 VDC
3000 W 9000 W
69.44 A at -43.2VDC
62.5 A at -48VDC
70A 70A
149° F (65° C) 149° F (65° C) 149° F (65° C)
All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds.
Mini Bus Bar
Mini Bus Bar
Mini Bus BarMini Bus Bar
21U 36U
19.45 in (49.40 cm)
19.74 in (50.14 cm) 19.74 in (50.14 cm)
2.2 in (5.59 cm) 2.2 in (5.59 cm)
13.2 lb (5.9 kg)
208.32 A at -43.2 VDC
187.5 A at -48 VDC 312.5 A at -48 VDC
Scalable Bus Bar
Scalable Bus Bar
Scalable Bus BarScalable Bus Bar
48.57 in (123.37 cm)
26 lb (11.79 kg)
15000 W
347.2 A at -43.2 VDC (equivalent of 175A per feed)
(equivalent of 175A per feed)
210A
Operating and
Operating and
Operating andOperating and Performance
Performance
PerformancePerformance Specifications for
Specifications for
Specifications forSpecifications for Facility DC
Facility DC
Facility DCFacility DC
Voltage
Voltage
VoltageVoltage
Nominal input voltage Operating voltage range Max Input voltage slew
rate Redundant feed voltages*
(A & B) Ripple/Noise Overshoot
Voltage transients
DA - 12160 North America — Version 7 — June 27, 2005
-48 VDC
-48VDC ± 10% or -43.2 VDC to -52.8 VDC
0.5V/uS
*A and B feeds must differ by no more than 5VDC during steady state operation
480 mV PARD** Must remain within regulation limits on all feeds
during startup or shutdown Must not exceed -60 VDC
Page 44
QuickSpecs
Technical Specifications
Current
Current
CurrentCurrent
In-rush current
In-rush current
In-rush currentIn-rush current
Input over-current
Input over-current
Input over-currentInput over-current
Max Input Current Slew
Max Input Current Slew
Max Input Current SlewMax Input Current Slew Rate
Rate
RateRate Max Rated Power
Max Rated Power
Max Rated PowerMax Rated Power Connections and Cables
Connections and Cables
Connections and CablesConnections and Cables
NOTE:
NOTE:
NOTE: NOTE: feeds.
** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Max steady state input current
Max steady state current per feed/total
Power bus boxes Mini bus bars Scalable bus bars
Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS
Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents.
1A/uS
3000W per server blade enclosure Compaq provided facility DC cable connection kit:
The facility DC connection kit supports the connection of up to four ­48VDC, RETURN pairs and ground
The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack.
*All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B
62.5A per server blade enclosure installed at ­48VDC
70 A/70A 210 A/210A 210 A/350A or equivalent of 175A per feed*
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA - 12160 North America — Version 7 — June 27, 2005
Page 45
Loading...