42U Rack with HP ProLiant BL25p System Installed42U Rack with HP ProLiant BL25p System Installed
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
1.
BL p-Class interconnects (2) in HP BladeSystem p-Class server blade enclosure (interconnect switch shown)
2.
HP ProLiant BL25p server blades (8) in HP BladeSystem p-Class server blade enclosure
3.
HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6)
What's New
What's New
What's NewWhat's New
Support for AMD Opteron 200 series Dual-Core processors
Models 275 (2.2GHz), 270 (2.0GHz) and 265 (1.8GHz)
1MB L2 cache per core
New HP BladeSystem p-Class 1U Power Enclosure
Up to two 2.6GHz AMD Opteron Processors with 1M L2 cache
Up to 16GB ECC PC3200 DDR (8 DIMM slots)
Integrated Smart Array 6i Plus with optional BBWC
DA - 12160 North America — Version 7 — June 27, 2005
Page 1
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
At A Glance
At A Glance
At A GlanceAt A Glance
Performance dual processor server blade designed with enterprise availability
HP ProLiant BL25p server blade includes:
AMD Opteron 200 series single and dual-core processors (dual capability)
Models 275 (2.2GHz), 270 (2.0GHz), 265 (1.8GHz), 252 (2.6GHz) and 250 (2.4GHz)
HP ProLiant BL25p Dual Port Fibre Channel Adapter (2-Gb) option for SAN connectivity
AMD 8131 and 8111 Chipsets
1024-MB or 2048-MB PC3200 Registered ECC 400MHz DDR memory, (2 x 1 Interleaved Memory), expandable to 16 GB
Five total network adapters:
Four PCI-X Gigabit Server NICs (embedded) with WOL and PXE (two single-port NC7781 and one dual-port NC7782)
Plus one additional 10/100 NIC dedicated to iLO Management
Smart Array 6i (integrated on system board Controller with optional battery-backed write cache)
Wide Ultra320 SCSI Drive Cage standard supports up to two 1" Wide Ultra320 hot plug hard drives
Integrated Lights-Out (iLO) Advanced Management (ASIC on motherboard)
Plugs vertically into 6U enclosure, 8 BL25p server blades per enclosure
Cisco Gigabit Ethernet Switch Module (CGESM) option for Gigabit Ethernet network adapter consolidation.
Integrated Access Tool for blade management and enhanced server blade documentation including Best Practices and
Common Procedures guides
HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Server Blade Enclosure:HP BladeSystem p-Class Server Blade Enclosure:
Server blades and interconnects blind mate into server blade enclosures for network connection and power
Server blade enclosure is 6U and holds up to 8 HP ProLiant BL25p server blades and 2 interconnects
Types of interconnects available: GbE Interconnect Switches, GbE2 and CGESM Interconnect Switches with optional
Fibre Channel pass through, Patch Panels or Patch Panel 2 with Fibre Channel pass through
HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Enclosures:HP BladeSystem p-Class Power Enclosures:
Use BL p-Class sizing tool to determine power based on your configuration
BL p-Class power enclosure provides shared, external, redundant power
Choose the HP BladeSystem p-Class 3U power enclosure or the HP BladeSystem p-Class 1U power enclosure
Choose single-phase or three-phase power
HP BladeSystem power enclosures with power supplies are not needed if using facility -48VDC ± 10%, in this case
purchase facility DC option kit
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
Distributes power from the power enclosure to the server blade enclosures
Four power distribution choices:
BL p-Class scalable bus bar
BL p-Class mini bus bar
BL p-Class power bus box
Dual power input kit for mini bus bar (required for support of two power enclosures)
HP ProLiant BL25p server blade, and p-Class server blade enclosure, interconnects and power enclosure protected by a
limited three year warranty with optional service uplifts available
NOTE:
NOTE:
NOTE: NOTE:
Power requirements for a HP BladeSystem p-Class-: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 2
QuickSpecs
Overview
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
++++
HP BladeSystem p-Class Server Blade Enclosure
HP BladeSystem p-Class Server Blade Enclosure
HP BladeSystem p-Class Server Blade EnclosureHP BladeSystem p-Class Server Blade Enclosure
++++
DA - 12160 North America — Version 7 — June 27, 2005
Page 3
QuickSpecs
Overview
OR
OR
OROR
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Patch Panel (shown) or
Patch Panel 2
BL p-Class Interconnects
BL p-Class Interconnects
BL p-Class InterconnectsBL p-Class Interconnects
GbE Interconnect Switch (shown) or GbE2 Interconnect Switch or
CGESM Interconnect Switch (fiber or copper-based)
++++
BL p-Class power enclosures and power supplies
BL p-Class power enclosures and power supplies
BL p-Class power enclosures and power suppliesBL p-Class power enclosures and power supplies
OR
OR
OROR
HP BladeSystem p-Class 1U power enclosure and power supplies
HP BladeSystem p-Class 1U power enclosure and power supplies
HP BladeSystem p-Class 1U power enclosure and power suppliesHP BladeSystem p-Class 1U power enclosure and power supplies
OR
OR
OROR
Facility DC
Facility DC
Facility DCFacility DC
DA - 12160 North America — Version 7 — June 27, 2005
Page 4
QuickSpecs
Overview
OR
OROR
OROR
OR
OROR
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Scalable bus bar
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
Configuration Steps
Configuration Steps
Configuration StepsConfiguration Steps
For a complete configuration of the HP ProLiant BL25p server blade, do the following:
1.
Select desired model, configuration and quantity of HP ProLiant BL25p server blades.
PLUS
PLUS
PLUSPLUS
2.
Decide how many HP BladeSystem p-Class Server Blade Enclosures to purchase (each enclosure can hold up to 8 HP ProLiant
BL25p server blades):
Mini bus bar
Bus boxes
Dual power input kit for mini bus bar
HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack
licenses (281404-B22)
Or
HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack trial
(243564-B22)
Or
HP BladeSystem p-Class server blade enclosure with enhanced backplane components with 8 HP BladeSystem Management
Suite licenses (380625-B22) - includes: a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the
following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch
Management Pack (VPM)
NOTE:
NOTE:
NOTE:NOTE:
server blade model is selected.
NOTE:
NOTE:
NOTE:NOTE:
Or
HP BladeSystem p-Class Enhanced Server Blade enclosures may be required depending on which HP ProLiant BL25p
The HP BL25p server blade does not currently support PMP. Future support is planned.
DA - 12160 North America — Version 7 — June 27, 2005
Page 5
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)(354100-B21)
NOTE:
NOTE:
NOTE: NOTE:
upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.
PLUS
PLUS
PLUSPLUS
3.
Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the Cisco GESM which contains a
single Switch per kit. One pair of interconnects is required with each blade enclosure:
RJ-45 Patch Panel 2 with Fibre Channel pass through (required for Fibre Channel connectivity on HP ProLiant BL20p G3
when using the patch panel interconnect) (306465-B21)
Or
RJ-45 Patch Panel (230766-B21)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T
downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination
of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with
or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for
ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T
downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000 T/TX/T SFP
modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel
connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM
Interconnect Switch)
Or
BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink
ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel
connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the GbE2
Interconnect Switch)
Or
BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000
T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre
Channel connectors) (321745 -B21) (required for BLXXp server blade Fibre Channel connectivity when using the GbE2
Interconnect Switch)
Or
BL p-Class C-GbE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink ports and 16 RJ-45 10/100 T/TX downlink
ports (249655-B21)
Or
BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX uplink ports and 16 RJ-45 10/100 T/TX downlink ports) (279720-B21)
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field
PLUS
PLUS
PLUSPLUS
4.
Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration. Use p-Class sizing tool to help
determine power configuration:
NOTE:
NOTE:
NOTE: NOTE:
Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a max of four power
supplies) (239162-001)
Or
Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a max of six power
supplies) (230769-001)
NOTE:
NOTE:
NOTE: NOTE:
Or
1U power enclosure with six power supplies (378284-B21)
Or
Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
3U Power enclosures and supplies can also be purchased separately see options list
DA - 12160 North America — Version 7 — June 27, 2005
.
Page 6
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Overview
1U power enclosure with two power supplies (380314-B21)
NOTE:
NOTE:
Additional power supplies can also be purchased separately - see options list below.
NOTE:NOTE:
PLUS
PLUS
PLUSPLUS
5.
Select power distribution (only required with 3U power enclosures):
Scalable bus bar - Supports up to 5 server blade enclosures* (240560-B21)
Or
Mini bus bar - Supports up to 3 server blade enclosures* (240559-B21)
Or
Power Bus Box - Supports only 1 server blade enclosure* (240562-B21)
Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. (364565-B21)
Or
HP Modular Distribution Unit 40 Amp (P/N 252663-D75)
Or
HP Modular Distribution Unit 24 Amp (P/N 252663-D74)
*
NOTE:
NOTE:
Maximum depends upon power input
NOTE:NOTE:
**
NOTE:
NOTE:
The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-
NOTE:NOTE:
class 1U power enclosure.
**
**
DA - 12160 North America — Version 7 — June 27, 2005
Page 7
QuickSpecs
Standard Features (Server Blade)
Processors
Processors
ProcessorsProcessors
Upgradeability
Upgradeability
UpgradeabilityUpgradeability
Cache Memory
Cache Memory
Cache MemoryCache Memory
Chipset
Chipset
ChipsetChipset
Memory
Memory
MemoryMemory
AMD Opteron Model 252 processor 2.6 GHz/1 GHz - 1MB (single-core)
AMD Opteron Model 250 processor 2.4 GHz/800 MHz - 1MB (single-core)
AMD Opteron Model 265 processor 1.8GHz/1 GHz (dual-core)
AMD Opteron Model 270 processor 2.0GHz/1 GHz (dual-core)
AMD Opteron Model 275 processor 2.2GHz/1 GHz (dual-core)
Upgradeable to dual processing.
1-MB Level 2 Cache per core
AMD 8131 and 8111 chipsets
Standard
Maximum
NOTE:
NOTE:
Memory must be installed in pairs.
NOTE:NOTE:
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
1024 MB or 2048 MB of 2-way interleaved PC3200 DDR SDRAM running at
400MHz (depending on model)
16 GB
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Manageability
Manageability
ManageabilityManageability
Internal Storage
Internal Storage
Internal StorageInternal Storage
Five network adapters total:
Four PCI-X Gigabit NICs (embedded) with WOL and PXE (two single-port NC7781 and one dual-port
NC7782)
One 10/100 iLO NIC dedicated to management
NOTE:
NOTE:
Must use a HP BladeSystem p-class server blade enclosure with enhanced backplane to utilize all
NOTE:NOTE:
four NIC's (281404-B22, 243564-B22 or 380625-B22).
Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board)
Hard Drives
Maximum Internal Storage
None ship standard
600 GB (internal drive cage) (2 x 300 GB Wide Ultra320, 1" drive
DA - 12160 North America — Version 7 — June 27, 2005
Page 8
QuickSpecs
Standard Features (Server Blade)
Fiber Channel on the
Fiber Channel on the
Fiber Channel on theFiber Channel on the
HP ProLiant BL25p server
HP ProLiant BL25p server
HP ProLiant BL25p serverHP ProLiant BL25p server
blade
blade
bladeblade
The following items are needed to connect the HP ProLiant BL25p server blade to the SAN:
1. HP ProLiant BL25/45p Dual-port Fibre Channel Adapter plugs into the Server Blades
The HP ProLiant BL25/45p dual-port Fibre Channel Adapter is compatible with the new HP
ProLiant BL25p and BL45p server blades (it cannot be used with a HP ProLiant BL20p, HP ProLiant
BL30p, HP ProLiant BL35p or HP ProLiant BL40p server blades)
Two ports on each Dual-port Fibre Channel Mezzanine Card provide a redundant Fibre Channel
connection to each server blade
Supports up to 2 Gb/s Fibre Channel equipment
Uses the QLogic chipset
Includes two small form factor pluggable transceivers with LC connectors for installation into the
Patch Panel 2, CGESM or GbE2 Interconnect Switch (with the Storage Connectivity Kit)
The HP ProLiant BL25p Dual-port Fibre Channel Adapter Option Kit must be ordered separately.
and
Allows pass through of both Ethernet and Fibre Channel signals
Ethernet signals exit out the rear of the RJ-45 Patch Panel G2; Fibre Channel signals exit out the
front of the RJ-45 Patch Panel G2
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the front of each RJ-45
patch panel 2 (16 Fibre Channel connections per server blade enclosure); for insertion of SPF
transceivers included with the HP ProLiant BL25p Dual-port Fibre Channel kit
or
2B. BL p-Class C-GbE2 or F-GbE2 or CGESM Interconnect Kit plus the optional Storage Connectivity Kit
Allows LAN signal consolidation and pass through of BL20p G3 Fibre Channel signals
Both LAN Ethernet signals and SAN Fibre Channel signals exit out the rear of the GbE2 or
CGESM Interconnect Switch (with the Storage Connectivity Kit option) via dedicated modular
interconnect modules
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the back of each GbE2
Interconnect Switch (16 Fibre Channel SPF slots per server blade enclosure)
SPF transceivers are included with the HP ProLiant BL25p Dual-port Fibre Channel Adapter kit
and
3. Compatible SAN
Optimized for StorageWorks arrays: HSG80 (MA8000, EMA12000, EMA16000); EVA5000;
EVA3000; XP48, XP128, XP512, XP1024; HP StorageWorks Modular Smart Array 1000 and
1500
Compatible with select 3rd party SANs (please see blade storage page for more details
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
)
Expansion Slots
Expansion Slots
Expansion SlotsExpansion Slots
No PCI slots all features are integrated
I/O cable connectors:
I/O cable connectors:
I/O cable connectors:I/O cable connectors:
(2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port
(2) I/O cables ship with every server blade enclosure
Tested USB devices (keyboard, mouse, floppy) are listed in the "Options" section of this QuickSpecs
DA - 12160 North America — Version 7 — June 27, 2005
Page 9
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Standard Features (Server Blade Enclosure and Interconnects)
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class InterconnectsHP BladeSystem p-Class Server Blade Enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade
Enclosures
Enclosures
EnclosuresEnclosures
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class Power
p-Class Power
p-Class Powerp-Class Power
Requirements
Requirements
RequirementsRequirements
6U (10.5-inch), 19-inch wide
Holds up to 8 HP ProLiant BL25p servers blades
10 bays per server blade enclosure 8 bays for server blades
2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect
Switch, GbE2 Interconnect Switch or CGESM Interconnect Switch)
Server blades blind mate into the server blade enclosure backplane for power and data connections
NOTE:
NOTE:
NOTE: NOTE:
which HP ProLiant BL25p server blade model is selected.
NOTE: NOTE:
and enables a field upgrade of a blade enclosure to support specific HP ProLiant BL25p server blade
models and provide a single, physical iLO port for the enclosure.
Server blade management module attached to the back of each HP BladeSystem p-Class 6U server
blade enclosure to report events all servers and provide asset and inventory information
(Every HP BladeSystem pClass server blade
enclosure requires two
interconnect switches OR
two RJ-45 patch panels)
Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of
HP ProLiant BL20p, HP ProLiant BL25p, HP ProLiant BL30p, HP ProLiant BL35p, HP ProLiant BL40p and
HP ProLiant BL45p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen
internal server network (NIC) ports to six external ports (four on a modular rear mounting interconnect
module and two on the switch front panel). This provides a total of twelve external ports per server blade
enclosure. Only one to all twelve external ports may be used per server blade enclosure.
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are for applications that require
network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure. The CGESM
supports the same and HP ProLiant BL25p Fibre Channel pass-through as the GbE2.
The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect
Switch or one CGESM with four (4) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable
(SFP) Modules
Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two CGESM
Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T
or Fiber SX external ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP
ProLiant BL25p Fibre Channel pass-through when using either the CGESM Interconnect Kit.
DA - 12160 North America — Version 7 — June 27, 2005
Page 10
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
The GbE2 Interconnect Kits (C-GbE2 and F-GbE2) are for applications that require network adapter
consolidation to 1000 Mbps (Gigabit Ethernet) and HP ProLiant BL25p Fibre Channel pass-through.
The ProLiant BL p-Class F-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and
two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45
10/100/1000 T/TX/T external ports per server blade enclosure.
The ProLiant BL p-Class C-GbE2 Interconnect Kit includes two GbE2 Interconnect Switches and
two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external
ports per server blade enclosure.
The optional ProLiant BL p-Class Storage Connectivity Kit (321745 -B21) is required for HP ProLiant
BL25p Fibre Channel pass-through when using either the C-GbE2 or F-GbE2 Interconnect Kit.
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter
consolidation to 100 Mbps (Fast Ethernet).
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two
DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX
external ports per server blade enclosure.
The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two
QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ45 10/100 T/TX external ports per server blade enclosure.
Also included (per Interconnect Switch):
One (1) RS-232 DB-9 front panel out-of-band management port
Redundant crosslink ports connecting the two interconnect switches
Redundant power inputs and on-board redundant fans
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Power ON, management, and per port status and speed LED indicators
Reset/power momentary push-button switch
HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD
Fully pre-configured for rapid deployment and immediate operation
The GbE Interconnect Kits (C-GbE and F-GbE) are for applications that require network adapter
consolidation to 100 Mbps (Fast Ethernet).
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE Interconnect Switches and two
DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX
external ports per server blade enclosure.
The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE Interconnect Switches and two
QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ45 10/100 T/TX external ports per server blade enclosure.
ProLiant BL Interconnect Switch Management System and Utilities:
Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level
user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging,
EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol,
broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP
client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and
duplex mode, and more.
DA - 12160 North America — Version 7 — June 27, 2005
Page 11
QuickSpecs
Standard Features (Server Blade Enclosure and Interconnects)
RJ-45 Patch PanelRJ-45 Patch Panel
(Two patch panels per kit)
(Every BL p-Class server
blade enclosure requires
two Interconnect switches
OR two RJ-45 patch
panels)
The Storage Connectivity Kit is used if HP ProLiant BL25p Fibre Channel signal pass-through is desired
when using the CGESM or GbE2 Interconnect Switch. Therefore, both LAN cable consolidation and SAN
connectivity is possible using a single interconnect option. Order one Storage Connectivity Kit per server
blade enclosure for Fibre Channel pass through.
The Storage Connectivity Kit includes two OctalFC Interconnect Modules that provide sixteen open
transceiver slots for the pluggable small form factor transceivers that come with each HP ProLiant
BL25/45p Dual port Fibre Channel Adapter. The Storage Connectivity Kit supports up to eight HP
ProLiant BL25p server blades (for a total of sixteen Fibre Channel signals).
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections
Supports Gigabit Ethernet network adapters
16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per
server blade enclosure)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Patch Panel 2 Patch Panel 2
Channel pass through)
(Two patch panels per kit)
(Every BL p-Class server
blade enclosure requires
two Interconnect switches
OR two RJ-45 patch
panels)
NOTE:
NOTE:
The Patch Panel 2
NOTE:NOTE:
or a Switch Interconnect
Kit is required for SAN
connectivity on the HP
ProLiant BL25p server
blade
Required Network
Required Network
Required NetworkRequired Network
Cabling
Cabling
CablingCabling
(with Fibre
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U server blade enclosures
Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections also
used to pass Fibre Channel signals for SAN connectivity
Supports Gigabit Ethernet network adapters
16 RJ-45 connectors on the back of each RJ-45 patch panel 2 (32 RJ-45 connections per server blade
enclosure)
Fibre Channel,
Fibre Channel,
Fibre Channel,Fibre Channel,
pass through
pass through
pass throughpass through
10Base-T
100Base-TX
1000Base-T
1000Base-SX
NOTE:
NOTE:
NOTE: NOTE:
http://www.compaq.com/products/servers
For cabling information, refer to the Web site at:
Fibre Channel signals travel from a HP ProLiant BL25p server blade with a
Dual-Port Fibre Channel Adapter through p-Class server blade enclosure
backplane. The Fibre Channel signals are terminated through the RJ-45
Patch Panel 2 in the interconnect bays. To provide redundancy each server
blade has two Fibre Channel signals and one Fibre Channel signal
terminates through the right RJ-45 Patch Panel 2, one Fibre Channel signal
travels terminates through the left RJ-45 Patch Panel 2.
8 Fibre Channel small form factor pluggable (SPF) transceiver slots on the
front of each RJ-45 patch panel 2 (16 Fibre Channel connections per server
blade enclosure); for insertion of SPF transceivers included with the Dual-port
Fibre Channel Adapter
DA - 12160 North America — Version 7 — June 27, 2005
Page 12
QuickSpecs
Standard Features (Power System and Rack Information)
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class Power System
p-Class Power System
p-Class Power Systemp-Class Power System
and Rack Information
and Rack Information
and Rack Informationand Rack Information
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class 3U Power
p-Class 3U Power
p-Class 3U Powerp-Class 3U Power
Enclosure
Enclosure
EnclosureEnclosure
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class 1U Power
p-Class 1U Power
p-Class 1U Powerp-Class 1U Power
Enclosure
Enclosure
EnclosureEnclosure
NOTE:
NOTE:
NOTE: NOTE:
Planning Whitepaper and sizing tool at
class/20p/index.html
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single
phase and three phase models available.
HP BladeSystem p-Class 3U power enclosure provides external, shared hot-plug power. Each threephase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures
hold up to four hot-plug power supplies to power the BL p-Class server blades and interconnects
Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using
facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single
phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power
enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully
populated with BL p-Class server blades and interconnects.
Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator.
NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If
using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.
To determine power configuration please refer to the HP BladeSystem p-Class Overview and
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
.
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class Power
p-Class Power
p-Class Powerp-Class Power
Distribution (only required
Distribution (only required
Distribution (only requiredDistribution (only required
with 3U power
with 3U power
with 3U powerwith 3U power
enclosures)
enclosures)
enclosures)enclosures)
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or
facility DC power) is distributed from the power enclosures to the server blade enclosures through the bus
bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open
from the center to enable easy rear access to the server blades and network cables. Power is distributed
redundantly through independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on the maximum number of server
blade enclosures planned for the rack:
HP BladeSystem p-Class scalable bus bar
HP BladeSystem p-Class mini bus bar
HP BladeSystem p-Class power bus box
NOTE:
NOTE:
To support a full 42U rack of HP ProLiant BL25p server blades (6 server blade enclosures), two
NOTE:NOTE:
mini bus bars are needed.
DA - 12160 North America — Version 7 — June 27, 2005
Page 13
QuickSpecs
Standard Features (Power System and Rack Information)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Scalable Bus Bar
Scalable Bus Bar
Scalable Bus BarScalable Bus Bar
Mini Bus Bar
Mini Bus Bar
Mini Bus BarMini Bus Bar
Power Bus Box
Power Bus Box
Power Bus BoxPower Bus Box
Required Power Source
Required Power Source
Required Power SourceRequired Power Source
Power Enclosures Supported
Power Enclosures Supported
Power Enclosures SupportedPower Enclosures Supported
1 or 2
1 or 2
1
Dual power input kit for mini bus
bar option (364565-B21)
required to support two power
enclosures.
NOTE:
NOTE:
To support a full 42U rack
NOTE:NOTE:
of BL p-Class server blades, use
two stacked pairs of mini bus bars.
Two 30amp redundant power feeds per power enclosure
Connectors
-NEMA receptacles
1-phase L6-30, 250v, 30A 3-wire
3-phase L15-30, 250V, 30A, 4-wire
Optimized for power cabling from bottom and network cabling from top
Server Blade Enclosures
Server Blade Enclosures
Server Blade EnclosuresServer Blade Enclosures
Supported
Supported
SupportedSupported
up to 5
up to 3
1
Max. Rack Space Occupied
Max. Rack Space Occupied
Max. Rack Space OccupiedMax. Rack Space Occupied
36U
21U
9U
DA - 12160 North America — Version 7 — June 27, 2005
Page 14
QuickSpecs
Standard Features
ProLiant Essentials
ProLiant Essentials
ProLiant EssentialsProLiant Essentials
Foundation Pack
Foundation Pack
Foundation PackFoundation Pack
Software for the ProLiant
Software for the ProLiant
Software for the ProLiantSoftware for the ProLiant
BL Server Blades
BL Server Blades
BL Server BladesBL Server Blades
ProLiant Essentials Rapid
Deployment Pack
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Rapid Deployment Pack (RDP) is an automated deployment and provisioning
solution for all ProLiant servers. RDP includes the Altiris Deployment Solution
and ProLiant Integration Module featuring ProLiant server pre-configured
events for OS installation, and optimized software drivers, firmware and
management agents. Every RDP CD includes 10-node trial licenses for
evaluation purposes. RDP requires a license for each server deployed and is
available for purchase with blade servers. For more information, visit
http://www.hp.com/servers/rdp
.
HP Systems Insight
Manager
Management Agents
Subscriber's Choice
HP Systems Insight Manager (HP SIM) help maximize system uptime and
performance and reduce system maintenance costs by providing proactive
notification of problems before those problems result in unplanned downtime
or reduced productivity. HP SIM is easy to set up to work with the Insight
Management Agents, integrated Light-Out and Remote Insight Light-Out
Edition, and Version Control Agents to deliver robust fault, configuration,
and asset management as well as remote administration. With HP Systems
Insight Manager customers will also be able to take advantage of role-based
security; the ability to manage ProLiant, Integrity, and HP9000 systems; and
plug-ins for storage, client, printer, and power management as well as server
rapid deployment, performance management, and workload management.
For more details on HP Systems Insight Manager visit
http://www.hp.com/go/hpsim
The Management Agents form the foundation for HP's Intelligent
Manageability strategy. They provide direct, browser-based access to indepth instrumentation built into HP servers, workstations, desktops, and
portables, and send alerts to HP Systems Insight Manager and other
enterprise management applications in case of subsystem or environmental
failures. For additional information about the Management Agents and other
management products from HP, please visit the management Web site at
http://www.hp.com/servers/manage
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides software and driver change
notifications for ProLiant products. Sign up at
http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
.
.
ROMPaq
software, and
configuration utilities
Insight Diagnostics Online
Edition
NOTE:
NOTE:
NOTE: NOTE:
http://www.hp.com/servers/proliantessentials
, support
For more information regarding ProLiant Essentials Software, please see the following URL:
DA - 12160 North America — Version 7 — June 27, 2005
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options, available in the RDP CD, SmartStart or
downloadable from Software and Drivers download pages, linked from the
SmartStart website at
The most advanced configuration analysis, reporting and troubleshooting
utilities used by HP and at your fingertips, available in SmartStart.
http://www.hp.com/go/support
.
Page 15
QuickSpecs
Standard Features
Optional ProLiant
Optional ProLiant
Optional ProLiantOptional ProLiant
Essentials Value Packs
Essentials Value Packs
Essentials Value PacksEssentials Value Packs
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to
address specific business problems and needs:
Workload Management Pack - provides easier management of complex environments, improving
overall server utilization and enabling Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant Server.
Performance Management Pack - a performance management solution that identifies and
explains hardware performance bottlenecks on ProLiant servers and attached options enabling
users to better utilize their valuable resources.
Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages
and steers traffic to the optimum route based on network conditions.
Vulnerability and Patch management Pack - identifies and remediates software security
vulnerabilities due to missing patches as well operating system configurations that can be
exploited by viruses, worms and other blended threats.
Virtual Machine Management Pack - provides central management and control of virtual
machines from Microsoft and VMware. Integrated approach provides the ability to manage both
physical and virtual resources from a single management console.
NOTE:
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer
NOTE:NOTE:
to
http://www.hp.com/servers/proliantessentials
QuickSpecs for more information.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
or the various ProLiant Essentials Value Pack product
SmartStart
SmartStart
SmartStartSmartStart
OS Support:
OS Support:
OS Support:OS Support:
Single-Core
Single-Core
Single-CoreSingle-Core
2.4 GHz and 2.6 GHz
2.4 GHz and 2.6 GHz
2.4 GHz and 2.6 GHz2.4 GHz and 2.6 GHz
models
models
modelsmodels
SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and
consistent server configurations. SmartStart 7.30 and later can now deploy all HP ProLiant BL25p server
blades, using the I/O port with an attached USB CD-ROM device. To obtain a copy of SmartStart for
your blade server, redeem the coupon that is included with your Blade server or order your copy from
the SmartStart web site. For more information, please visit the SmartStart Web site at
http://www.hp.com/servers/smartstart
SmartStart version supported (minimum): SmartStart 6.20
Microsoft Windows 2000 Server
Microsoft Windows 2000 Advanced Server
Windows Server 2003, Standard Edition
Windows Server 2003, Enterprise Edition
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 4
SuSE Linux Enterprise Server 8
SuSE Linux Enterprise Server 9
NOTE:
NOTE:
For a complete and up-to-date listing of supported OSs and versions, please visit our OS
NOTE:NOTE:
Support Matrix at:
NOTE:
NOTE:
For an up-to-date listing of the latest drivers available for the HP ProLiant BL p-Class, please see:
Microsoft Windows 2000 Server (licensed by core)
Microsoft Windows 2000 Advanced Server (licensed by core)
Windows Server 2003, Standard Edition (licensed by processor socket)
Windows Server 2003, Enterprise Edition (licensed by processor socket)
Red Hat Enterprise Linux 3 Update 5
Red Hat Enterprise Linux 4 Update 2
SuSE Linux Enterprise Server 9 SP1
NOTE:
NOTE:
For a complete and up-to-date listing of supported OSs and versions, please visit our OS
NOTE:NOTE:
Support Matrix at: http://www.hp.com/go/supportos
NOTE:
NOTE:
For an up-to-date listing of the latest drivers available for the HP ProLiant BL p-Class, please see
For a more complete and up-to-date information on Linux support, please visit HP Linux Web
NOTE:NOTE:
site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html
Integrated Lights-Out Advanced (iLO)
Virtual Text and Graphical Remote Console *
Virtual CD-ROM*
Virtual Floppy *
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Automatic Server Recovery-2 (ASR-2)
Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM Based Setup Utility (RBSU)
Advanced Configuration and Power Interface Specification Ready (ACPI)
Server and Interconnect Switch Health Logs
Redundant Power Supply Utility
Pre-Failure Warranty (covers processors, as well as hard drives and memory)
Interconnect Switch Management System and Utilities (Interconnect Switch option)
Integrated Management Log (IML)
Off-Line Backup Processor capability
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Network adapter teaming set-up utility
* Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL pClass server.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
.
:
.
.
DA - 12160 North America — Version 7 — June 27, 2005
Page 17
QuickSpecs
Standard Features
Availability
Availability
AvailabilityAvailability
Power redundancy: Redundant AC feeds into power enclosures, redundant DC feeds from power
enclosure to server blade enclosures,
N + N redundant power supplies
Dual-Port Fibre Channel Mezzanine Card for redundant SAN connection
Two hot-plug SCSI hard drive bays and integrated RAID (Smart Array 6i Plus) on every server blade
(Battery-backed write cache is optional.)
Redundant ROM on each server blade
ECC Memory
Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load
balancing)
Interconnects Switch Availability
Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
Two network connections per server blade bay (four NICs total) routed to two redundant
interconnect switches
Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports
per each interconnect switch
Redundant front panel ports per each interconnect switch for diagnostics, management, and
additional uplinks
Redundant serial ports
Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning tree protocol support
for loop-free path redundancy
Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and
failover
Redundant configuration files and operating system firmware images in memory (GbE2 switch)
Redundant fans per each interconnect switch
Redundant 1+1 power to each interconnect switch
Support for ProLiant network adapter teaming
Redundant configurable community strings and SNMP trap manager hosts
Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Security
Security
SecuritySecurity
Power-on password
Administrator's password
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
Interconnect switch multilevel user names and passwords, management interface time out period setting,
SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication
and authorization*, and IP address restriction
* CGESM and GbE2 Interconnect Switch only
DA - 12160 North America — Version 7 — June 27, 2005
Page 18
QuickSpecs
Standard Features
Minimum Rack
Minimum Rack
Minimum RackMinimum Rack
Requirements
Requirements
RequirementsRequirements
Rack Airflow
Rack Airflow
Rack AirflowRack Airflow
Requirements
Requirements
RequirementsRequirements
Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria:
Compatible with 19-inch Standard EIA rail sets
EIA rail-to-rail depth is 29 - 30"
Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from
rear RETMA rail to rear door, inclusive in the 36-inch overall depth)
Ample room for top and bottom cable egress (approximately 8 square inches for full rack
configuration with patch panel)
Must be capable of supporting 1600 lb (for full rack configuration)
Perforated front and rear doors to accommodate front-to-back cooling
Must have 65% open perforation on server blade enclosure doors to support airflow requirements
Optimized for use with the HP 10000 Series racks
NOTE:
NOTE:
If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are
NOTE:NOTE:
required.
Rack 10000 series Cabinets
Rack 10000 series Cabinets
Rack 10000 series CabinetsRack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum
cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION:CAUTION:
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be
a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION:
CAUTION:CAUTION:
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE:
NOTE:
NOTE: NOTE:
provided with the server, or to the server documentation located in the Support section at the following
URL:
http://www.hp.com/servers/bl25p
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
If a third-party rack is used, observe the following additional requirements to ensure
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
For additional information, refer to the Setup and Installation Guide or the Documentation CD
.
Factory Express Portfolio
Factory Express Portfolio
Factory Express PortfolioFactory Express Portfolio
for Servers and Storage
for Servers and Storage
for Servers and Storagefor Servers and Storage
HP Factory Express offers configuration, customization, integration and deployment services for HP
servers and storage products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging and custom packaging. HP products supported through Factory Express include: a wide array of
servers and storage: HP Integrity, HP ProLiant & HP ProLiant Server Blades, HP BladeSystem, HP 9000
servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and
configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales
representative or go to
DA - 12160 North America — Version 7 — June 27, 2005
http://www.hp.com/go/factory-express
.
Page 19
QuickSpecs
Standard Features
Service and Support
Service and Support
Service and SupportService and Support
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of
hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide
network of resellers and service providers. In addition 90-day's getting started software telephone support
may be covered under the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services.
NOTE:
NOTE:
Sever Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
NOTE:NOTE:
NOTE:
NOTE:
Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor,
NOTE:NOTE:
3-year on-site support.
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMWare-based IT solutions helping to deliver high level of application availability. Response times
range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the HP
BladeSystem p-Class blade enclosure that the server blade is installed in as well as interconnects, power
enclosure with power supplies and power distribution.
NOTE:
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales offices or
NOTE:NOTE:
resellers or visit our worldwide Web site on the internet at:
NOTE:
NOTE:
For more complete information on HP Services offerings, customers and resellers, please visit us
NOTE:NOTE:
at:
http://www.hp.com/hps
NOTE:
NOTE:
Additional information regarding worldwide limited warranty and technical support is available
ProLiant BL25p 2.0GHz-ProLiant BL25p 2.0GHz1MB, DC 2GB (2P)
1MB, DC 2GB (2P)
1MB, DC 2GB (2P)1MB, DC 2GB (2P)
392441-B21
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory
Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller
Hard Drives
Hard Drives
Hard DrivesHard Drives
Internal Storage
Internal Storage
Internal StorageInternal Storage
Optical Drive
Optical Drive
Optical DriveOptical Drive
Form Factor
Form Factor
Form FactorForm Factor
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory
Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller
Hard Drives
Hard Drives
Hard DrivesHard Drives
Internal Storage
Internal Storage
Internal StorageInternal Storage
Optical Drive
Optical Drive
Optical DriveOptical Drive
Form Factor
Form Factor
Form FactorForm Factor
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
(1) AMD Opteron Model 265 dual-core 1.8 GHz standard (up to 2
supported)
1-MB Level 2 cache per core
1024-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (2x512 MB)
Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Smart Array 6i Controller (integrated on system board)
None ship standard
Up to 600-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
(2) AMD Opteron Model 270 dual-core 2.0 GHz standard (up to 2
supported)
1-MB Level 2 cache per core
2048-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (4x512 MB)
Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Smart Array 6i Controller (integrated on system board)
None ship standard
Up to 600-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
ProLiant BL25p 2.2GHz-
ProLiant BL25p 2.2GHz-
ProLiant BL25p 2.2GHz-ProLiant BL25p 2.2GHz1MB, DC 2GB (2P)
1MB, DC 2GB (2P)
1MB, DC 2GB (2P)1MB, DC 2GB (2P)
392439-B21
Processor(s)
Processor(s)
Processor(s)Processor(s)
Cache Memory
Cache Memory
Cache MemoryCache Memory
Memory
Memory
MemoryMemory
Network Adapter
Network Adapter
Network AdapterNetwork Adapter
Storage Controller
Storage Controller
Storage ControllerStorage Controller
Hard Drives
Hard Drives
Hard DrivesHard Drives
Internal Storage
Internal Storage
Internal StorageInternal Storage
Optical Drive
Optical Drive
Optical DriveOptical Drive
Form Factor
Form Factor
Form FactorForm Factor
DA - 12160 North America — Version 7 — June 27, 2005
(2) AMD Opteron Model 275 dual-core 2.2 GHz standard (up to 2
supported)
1-MB Level 2 cache per core
2048-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (4x512 MB)
Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Smart Array 6i Controller (integrated on system board)
None ship standard
Up to 600-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
(1) AMD Opteron Model 250 single-core 2.4 GHz standard (up to 2
supported)
1-MB Level 2 cache per core
1024-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (2x512MB)
Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Smart Array 6i Controller (integrated on system board)
None ship standard
Up to 600-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
(1) AMD Opteron Model 252 single-core 2.6 GHz standard (up to 2
supported)
1-MB Level 2 cache per core
1024-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (2x512MB)
Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Smart Array 6i Controller (integrated on system board)
None ship standard
Up to 600-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
DA - 12160 North America — Version 7 — June 27, 2005
(2) AMD Opteron Model 252 single-core 2.6 GHz standard (up to 2
supported)
1-MB Level 2 cache per core
2048-MB (Standard) to 16-GB (Maximum) of 2-way interleaved capable
PC3200 DDR SDRAM running at 400MHz (4x512MB)
Four Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Smart Array 6i Controller (integrated on system board)
None ship standard
Up to 600-GB maximum (with optional hard drives)
None
Plugs vertically into HP BladeSystem p-Class Server Blade Enclosure
Page 22
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Configuration Information Factory Integrated Models
NOTE:
NOTE:
NOTE: NOTE:
Configure-to-order servers must start with a CTO Chassis.
NOTE:
NOTE:
NOTE: NOTE:
Step 1: Base Server Blade Configuration
Step 1: Base Server Blade Configuration
Step 1: Base Server Blade ConfigurationStep 1: Base Server Blade Configuration
Models
Models
ModelsModels
Step 2: Choose Required Options (one of the following from each list unless otherwise
Step 2: Choose Required Options (one of the following from each list unless otherwise
Step 2: Choose Required Options (one of the following from each list unless otherwiseStep 2: Choose Required Options (one of the following from each list unless otherwise
noted):
noted):
noted):noted):
Processors
Processors
ProcessorsProcessors
Memory
Memory
MemoryMemory
Communications
Communications
CommunicationsCommunications
HP does not allow factory integration of options into standard models listed above.
This product offering does not support HP Factory Express Server Configuration Level 1.
HP ProLiant BL25p CTO Blade
Configurable Model ships with:
Configurable Model ships with:
Configurable Model ships with:Configurable Model ships with:
One additional 10/100 NIC dedicated to iLO Management Four Gigabit NICs
(embedded) with WOL and PXE
NOTE:
NOTE:
Two can be upgraded to multifunction network adapters)
NOTE:NOTE:
One additional 10/100 NIC dedicated to iLO Management
HP BL25p 0265 1.8GHz DC FIO Base
HP BL25p 0270 2.0GHz DC FIO Base
HP BL25p 0275 2.2GHz DC FIO Base
HP BL25p O252 2.6GHz SC FIO Base
HP BL25p O250 2.4GHz SC FIO Base
For dual processor configurations choose one of the above FIO choices, plus one of
the matching option kits below:
HP BL25p Opteron 2.2GHz-1M DC Processor Option Kit
HP BL25p Opteron 2.0GHz-1M DC Processor Option Kit
HP BL25p Opteron 1.8GHz-1M DC Processor Option Kit
HP BL25p Opteron 2.6GHz-1M SC Processor Option Kit
HP BL25p Opteron 2.4GHz-1M SC Processor Option Kit
NOTE:
NOTE:
Two-way memory interleaving is enabled when an identical pair of DIMMs is
NOTE:NOTE:
installed.
1GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
NOTE:
NOTE:
Must install in pairs
NOTE:NOTE:
2GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
4GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory Integration
Step 4: Choose Additional Options for Factory IntegrationStep 4: Choose Additional Options for Factory Integration
NOTE:
NOTE:
NOTE: NOTE:
subsystem options, please refer to the "Options" section below.
For additional options, including server blade enclosure with enhanced backplanes, interconnect options and power
FC Adapter Card BL25p/45p
DA - 12160 North America — Version 7 — June 27, 2005
381881-B21
Page 23
QuickSpecs
Options
ProLiant Essentials
ProLiant Essentials
ProLiant EssentialsProLiant Essentials
Value Pack Software
Value Pack Software
Value Pack SoftwareValue Pack Software
ProLiant Essentials Vulnerability and Patch Management Pack, 1 Server + 10Desktop
Bundle License
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License
ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity
License
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for
New Servers
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking License for
Installed servers
ProLiant Essentials Server Migration Pack, 25-Server License
ProLiant Essentials Server Migration Pack, 50-Server License
ProLiant Essentials Server Migration Pack, 100-Server License
ProLiant Essentials Server Migration Pack, 10-Server License
NOTE:
NOTE:
This license allows 10 servers to be migrated from a physical server to 10
NOTE:NOTE:
virtual machines. Or this license can be used to migrate 10 virtual machines from one
virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware
ESX or Microsoft Virtual Server 2005.
ProLiant Essentials Server Migration Pack, Single-Server License
ProLiant Essentials Server Migration Pack, Flexible-Quantity License
ProLiant Essentials Server Migration Pack, Tracking license
ProLiant Essentials Virtual Machine Management Pack, SINGLE LIC IP CCAO-
NOTE: NOTE:
multiple licenses with a single activation key. The quantity ordered for this part number
will be the quantity of licenses included in the kit in the form of a corresponding
activation key. Use the same key to activate all licenses in the actual quantity ordered.
For a given order, one kit will be delivered with the activation key, and
documentation.
NOTE: NOTE:
Purchase of this part number entitles the customer to deploy additional licenses of the
product under the terms of the existing Activation Key Agreement.
NOTE:
NOTE:
Nothing is delivered in conjunction with the purchase of this part number. Visit
For use with multiple servers. This part number can be used to purchase
NOTE:NOTE:
multiple licenses with a single activation key. The quantity ordered of this part number
will be the quantity of licenses included in the kit in the form of a corresponding
activation key. Use the same key to activate all licenses in the actual quantity ordered.
For a given order, one kit will be delivered with activation key, and documentation.
NOTE: NOTE:
Purchase of this part number entitles the customer to deploy additional licenses of the
product under the terms of the existing Activation Key Agreement.
NOTE:
Flexible Quantity License Kit
License-Only - for use with a Master License Agreement
ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning
Manager version 2.0)
NOTE:
NOTE:
NOTE:NOTE:
following URL:
NOTE:
NOTE:
NOTE:NOTE:
Value Packs. Refer to URL
ProLiant Essentials Value Pack product QuickSpecs for more information.
For use with signed and implemented Activation Key Agreements only.
Nothing is delivered in conjunction with the purchase of this part number. Visit
This license allows 10 servers to be managed and deployed via the
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments.
This license allows 10 servers to be managed and deployed via the
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments.
This license allows 1 server to be managed and deployed via the Deployment
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments.
This license allows 1 server to be managed and deployed via the Deployment
Not necessary if you purchase the server blade enclosure with 8 Rapid
Rapid Deployment pack is now available in Linux only environments.
For more information regarding ProLiant Essentials Software, please see the
http://hp.com/servers/proliantessentials
Flexible and volume quantity license kits are available for ProLiant Essentials
http://hp.com/servers/proliantessentials
.
or the various
374055-B21
306697-B21
306698-B21
269817-B21
267196-B21
302127-B21
302128-B21
303284-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 25
QuickSpecs
Options
Processor
Processor
ProcessorProcessor
Memory
Memory
MemoryMemory
(SDRAM DIMMs)
Hard Drives
Hard Drives
Hard DrivesHard Drives
HP BL25p Opteron 2.2GHz-1M DC Processor Option Kit
HP BL25p Opteron 2.0GHz-1M DC Processor Option Kit
HP BL25p Opteron 1.8GHz-1M DC Processor Option Kit
HP BL25p Opteron 2.6GHz-1M SC Processor Option Kit
HP BL25p Opteron 2.4GHz-1M SC Processor Option Kit
4GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
2GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
1GB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot PlugUltra320 SCSI – Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
146.8-GB 15,000 rpm U320 Universal Hard Drive (1")
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Please see the following Controller QuickSpecs for Technical Specifications
NOTE:NOTE:
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak
Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support,
and additional information:
Dual port Fibre Channel Adapter (2-Gb) for HP ProLiant BL25p server blade (shared
with the HP ProLiant BL45p server blade)
NOTE:
NOTE:
When using this card, the Patch Panel 2, CGESM, or GbE2 Interconnect
NOTE:NOTE:
Switch (with Storage Connectivity Kit) must be used to provide the Fibre Channel pass
through.
NOTE:
NOTE:
The BL30p/35p and BL20p dual-port Fibre Channel adapters are not
NOTE:NOTE:
compatible with the HP ProLiant BL25p server blade.
346914-B21
381881-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 26
QuickSpecs
Options
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade
Enclosures
Enclosures
EnclosuresEnclosures
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane
components and the HP BladeSystem Management Suite
NOTE:
NOTE:
NOTE: NOTE:
backplane components, a single copy of Systems Insight Manager (SIM) and 8
licenses for each of the following products: Rapid Deployment Pack (RDP),
Performance Management Pack (PMP) and the Vulnerability and Patch Management
Pack (VPM).
NOTE:
NOTE:
The HP ProLiant BL25p server blade does not currently support PMP. Future
NOTE:NOTE:
support is planned.
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane
components (ProLiant Essentials Rapid Deployment Pack Trial)
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane
components (8 ProLiant Essentials Rapid Deployment Licenses)
NOTE:
NOTE:
NOTE: NOTE:
backplane components may be required depending on which HP ProLiant BL25p
server blade model is selected.
For additional information regarding Blade Enclosure Compatibility, please visit the
following URL:
HP BladeSystem p-Class Server Blade Enclosure Upgrade Kit (option)
NOTE:
NOTE:
Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced
NOTE:NOTE:
backplane components and enables a field upgrade of a blade enclosure to support
BL p-class blades and provide a single, physical iLO port for the enclosure.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Includes a HP BladeSystem p-Class Server Blade Enclosure with enhanced
HP BladeSystem p-Class Enhanced Server Blade Enclosures with enhanced
HP BladeSystemHP BladeSystem
p-Class Interconnects
p-Class Interconnects
p-Class Interconnectsp-Class Interconnects
ProLiant BL p-Class RJ-45 Patch Panel 2 with Fibre pass-through (pair) (required for
FC connectivity)
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class RJ-45 Patch Panel (pair)
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class C-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches
and two QuadT2 Interconnect Modules)
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class F-GbE2 Interconnect Kit (with pair of GbE2 Interconnect Switches
and two QuadSX Interconnect Modules)
NOTE:
NOTE:
NOTE:NOTE:
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit only
NOTE:
NOTE:
NOTE: NOTE:
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor
Pluggable (SFP) Modules
Modules and two Fibre Channel signal conditioning cards)
Only one interconnect kit required per server blade enclosure.
Only one interconnect kit required per server blade enclosure.
Only one interconnect kit required per server blade enclosure.
Only one interconnect kit required per server blade enclosure.
Two CGESM interconnect kits required per server blade enclosure.
Two CGESM interconnect kits required per server blade enclosure.
306465-B21
230766-B21
283192-B21
283193-B21
378926-B21
378927-B21
378928-B21
378929-B21
321745-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 27
QuickSpecs
Options
NOTE:
NOTE:
NOTE: NOTE:
CGESM or GbE2 Interconnect Switch.
NOTE:
NOTE:
NOTE: NOTE:
NOTE:
NOTE:
NOTE: NOTE:
ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches
and two QuadT Interconnect Modules)
NOTE:
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:NOTE:
NOTE:
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
NOTE:NOTE:
recommended that a patch panel or GbE2 Interconnect Switch option be used if
server NIC speeds to 1000 Mbps are required.
NOTE:
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels
NOTE:NOTE:
on the ends of any individual rack or a series of coupled racks and the front and rear
doors must be installed in any racks containing more than one ProLiant BL p-Class
GbE Interconnect Kit.
ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches
and two DualTSX Interconnect Modules)
NOTE:
NOTE:
Only one interconnect kit required per server blade enclosure.
NOTE:NOTE:
NOTE:
NOTE:
The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is
NOTE:NOTE:
recommended that a patch panel option be used if server NIC speeds to 1000 Mbps
are required.
NOTE:
NOTE:
To meet applicable radio frequency (RF) emission limits, the sidewall panels
NOTE:NOTE:
on the ends of any individual rack or a series of coupled racks and the front and rear
doors must be installed in any racks containing more than one ProLiant BL p-Class
GbE Interconnect Kit.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Required for BL20P G3 Fibre Channel signal pass through when using the
Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit.
Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit.
249655-B21
279720-B21
HP BladeSystem p-Class
HP BladeSystem p-Class
HP BladeSystem p-ClassHP BladeSystem p-Class
Power Options
Single Phase 3U Power Enclosure with 4 power supplies
(Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need to
order additional power supplies with this option kit)
3 Phase 3U Power Enclosure with 6 power supplies
(3 Phase 3U Power Enclosure holds a maximum of 6 power supplies; no need to
order additional power supplies with this option kit)
Single Phase 3U Power Enclosure (empty)
(Holds up to 4 power supplies; power supplies are not included in this kit)
3 Phase 3U Power Enclosure (empty)
(Holds up to 6 power supplies; power supplies are not included in this kit)
Single 3U Power Supply
1U Power Enclosure with six power supplies
1U Power Enclosure with two power supplies
Single 1U Power Supply
Facility DC Power Connection
Use p-Class sizing tool to help determine power configuration:
DA - 12160 North America — Version 7 — June 27, 2005
Page 28
QuickSpecs
Options
Power Distribution (only
Power Distribution (only
Power Distribution (onlyPower Distribution (only
required with 3U power
required with 3U power
required with 3U powerrequired with 3U power
enclosures)
enclosures)
enclosures)enclosures)
SAN Switches
SAN Switches
SAN SwitchesSAN Switches
HP BladeSystem p-Class Scalable Bus Bar
HP BladeSystem p-Class Mini Bus Bar
HP BladeSystem p-Class Bus Power Box
Dual Power Input Kit for Mini Bus Bar
HP Modular Distribution Unit 40 Amp
HP Modular Distribution Unit 24 Amp
NOTE:
NOTE:
The Modular Distribution Unit Kits excludes the extension bars as they are not
NOTE:NOTE:
required with the HP BladeSystem p-class 1U power enclosure.
HP BladeSystem Power Extension Kit
NOTE:
NOTE:
This kit is specifically for HP BladeSystem p-Class customers who want to
NOTE:NOTE:
upgrade their standard server blade enclosures to enhanced server blade enclosures
and would like to install an additional, redundant 3U power enclosure above the
server blade enclosures rather than below them. The option kit consists of two
extension cable assemblies - one for each side (A and B).
Brocade 4GB SAN Switch, Base
Brocade 4GB SAN Switch, full fabric
Brocade 4GB SAN Switch, power pack
McDATA 4Gb SAN Switch
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
240560-B21
240559-B21
240562-B21
364565-B21
252663-D75
252663-D74
381686-B21
A7533A
A7534A
A7535A
A8001A
Other Options
Other Options
Other OptionsOther Options
Tape Libraries
Tape Libraries
Tape LibrariesTape Libraries
HP BladeSystem p-Class Diagnostic Station
NOTE:
NOTE:
The Diagnostic Station allows access to the ProLiant BL20p server blade and
NOTE:NOTE:
the BL p-Class interconnect switch outside of the server enclosure. The option provides
power and a data interface so that "offline" upgrade and diagnostic functions may be
performed.
HP BladeSystem p-Class Power Enclosure Shipping Bracket Option Kit
Please reference the Magneto-Optical Jukebox data sheets at
NOTE:NOTE:
http://www.hp.com/go/optical
complete solution
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical JukeboxesHP StorageWorks 9.1 GB High-end Optical Jukeboxes
1200mx, 4 drive, up to 128 slots
1200mx, 6 drive, up to 128 slots
2200mx, 4 drive, up to 238 slots
2200mx, 6 drive, up to 238 slots
2200mx, 10 drive, up to 238 slots
NOTE:
NOTE:
Please reference the Magneto-Optical Jukebox data sheets at
NOTE:NOTE:
http://www.hp.com/go/optical
complete solution.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Please reference the Ultra Density Optical Jukebox QuickSpecs at
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Please see the StorageWorks Modular Smart Array 1500 QuickSpecs for
For additional information regarding the HP Serviceguard for Linux License,
201723-B22
218231-B22
218960-B21
286763-B21
201723-B22
AA986A
307754-B26
305199-B26
USB Options
USB Options
USB OptionsUSB Options
HP Rack 5000 Series
HP Rack 5000 Series
HP Rack 5000 SeriesHP Rack 5000 Series
(Graphite Metallic)
Rack Options for Rack
Rack Options for Rack
Rack Options for RackRack Options for Rack
5000 Series
5000 Series
5000 Series5000 Series
USB 1.44-MB External Diskette Drive (Carbonite)
USB 2-Button Optical Mouse (Carbonite)
USB Optical Scroll Mouse (Carbonite)
256MB HP Drive Key II (USB 2.0)
HP 5642 Rack - Unassembled
Stabilizer Kit for 5642 Rack (Graphite Carbon)
NOTE:
NOTE:
NOTE: NOTE:
Baying Kit for 5642 Rack (Graphite Carbon)
NOTE:
NOTE:
NOTE: NOTE:
The stabilizing kit is used to prevent rack from tipping over.
The baying kit is used to join two or more HP 5642 racks.
DC141B
DC172B
DD441B
PH657A
358254-B21
374493-B21
374499-B21
DA - 12160 North America — Version 7 — June 27, 2005
Page 32
QuickSpecs
Options
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Rack 10000 Series
Rack 10000 Series
Rack 10000 SeriesRack 10000 Series
(Graphite Metallic)
Rack, HP Infrastructure 42U (HV)
Rack, HP Infrastructure 42U (LV)
HP Rack 10842 (42U) - Pallet
HP Rack 10842 (42U) - Shock Pallet
HP S10614 (14U) Rack Cabinet - Shock Pallet
HP Rack 10647 (47U) Cabinet - Pallet
HP Rack 10647 (47U) Cabinet - Crated
HP Rack 10642 (42U) Cabinet - Pallet
HP Rack 10642 (42U) Cabinet - Shock Pallet
HP Rack 10642 (42U) Cabinet - Crated
HP Rack 10636 (36U) Cabinet - Pallet
HP Rack 10636 (36U) Cabinet - Shock Pallet
HP Rack 10636 (36U) Cabinet - Crate
HP Rack 10622 (22U) Cabinet - Pallet
HP Rack 10622 (22U) Cabinet - Shock Pallet
HP Rack 10622 (22U) Cabinet - Crated
NOTE:
NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck
NOTE:NOTE:
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels)
-B23 (crated) used for air shipments of empty racks
Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE:
NOTE:
Please see the Rack 10000 QuickSpecs for Technical Specifications such as
NOTE:NOTE:
height, width, depth, weight, and color:
Rack Options for HPRack Options for HP
Rack 10000 Series
Rack 10000 Series
Rack 10000 SeriesRack 10000 Series
HP Light kit for 10000 series rack
HP Plinth kit for 10000 series rack
42U Side Panel – Graphite Metallic
36U Side Panel – Graphite Metallic
47U Side Panel – Graphite Metallic
NOTE:
NOTE: For additional information regarding Rack Options, please see the following
ProLiant BL p-Class Bus Bar Telco Rack Kit
ProLiant BL p-Class Enclosure Telco Rack Kit
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
For additional information regarding HP KVM Switches and options, please
262585-B21
262586-B21
373035-B21
336047-B21
263474-B21
263474-B22
263474-B23
263474-B24
263474-B25
245249-B21
266076-B21
Service and Support
Service and Support
Service and SupportService and Support
Offerings
Offerings
Offerings Offerings
Services)
(HP Care Pack
NOTE:
NOTE: The HP Care Pack services for ProLiant BL p-Class server blades, cover the
NOTE:NOTE:
server blade and the p-Class blade enclosure that the server blade is installed in as
well as interconnects, power enclosure with power supplies and power distribution.
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site ServiceHardware Services On-site Service
Next Business Day On-site Service, 5-Day x 9-Hour Coverage,
3 Years
Next Business Day On-site Service, 5-Day x 9-Hour Coverage,
3 Years, Electronic
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
UA203A
UA203E
UA204A
UA204E
UA205A
UA205E
UA206A
UA206E
DA - 12160 North America — Version 7 — June 27, 2005
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
UA219A
ProLiant BL p-Class Blade Server Hardware Installation, Electronic
ProLiant BL p-Class Enclosure and Server Blade Hardware Installation
ProLiant BL p-Class Enclosure and Server Blade Hardware Installation, Electronic
Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment Pack
on a Customer supplied server designated as a Deployment Server. Includes the
deployment of a single server. This new server will be deployed using either one of the
pre-configured scripts or an image. In addition, the service will provide for the capture
and storage of the configuration of the newly deployed server and orientation on
product usage. To be delivered during standard office ours, standard office days.
Provides for the Installation and Start-up of ProLiant Essentials Rapid Deployment Pack
on a Customer supplied server designated as a Deployment Server. Includes the
deployment of a single server. This new server will be deployed using either one of the
pre-configured scripts or an image. In addition, the service will provide for the capture
and storage of the configuration of the newly deployed server and orientation on
product usage. To be delivered during standard office ours, standard office days.
Electronic.
Provides for the Installation and Start-up of Rapid Deployment Pack Implementation of
Rapid Deployment Pack (Basic)
Provides for the Installation and Start-up of Rapid Deployment Pack Implementation of
Rapid Deployment Pack (Basic) (Electronic)
Provides for the Installation and Start-up of System Insight Manager
Provides for the Installation and Start-up of System Insight Manager (Electronic)
Provides for the Installation and Start-up of System Insight Manager Agents
Provides for the Installation and Start-up of System Insight Manager (Electronic)
NOTE:
NOTE:
For more information, customer/resellers can contact
NOTE:NOTE:
http://www.hp.com/hps/carepack/services/
Software Operating Environment Care Packs
Software Operating Environment Care Packs
Software Operating Environment Care PacksSoftware Operating Environment Care Packs
Microsoft Software Operating Environment Software Telephone 9x5 - 3 incident
Microsoft Software Operating Environment Software Telephone 9x5 - 3 incident
(Electronic)
Red Hat Software Operating Environment Software Telephone 9x5 - 10 incident
Red Hat Software Operating Environment Software Telephone 9x5 - 10 incident
DA - 12160 North America — Version 7 — June 27, 2005
Page 35
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Memory
HP ProLiant BL25p Server Blade (2P Models)
HP ProLiant BL25p Server Blade (2P Models)
HP ProLiant BL25p Server Blade (2P Models)HP ProLiant BL25p Server Blade (2P Models)
Standard Memory
Standard Memory
Standard MemoryStandard Memory
2048-MB PC3200 Registered DDR SDRAM DIMM installed (4 x 512MB SDRAM DIMM)
Standard Memory Plus Optional Memory
Standard Memory Plus Optional Memory
Standard Memory Plus Optional MemoryStandard Memory Plus Optional Memory
Up to 10240-MB of DDR SDRAM DIMM memory is available with the installation of optional DDR SDRAM DIMM memory
expansion kits.
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional MemoryStandard Memory Replaced with Optional Memory
Up to 16384-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional
SDRAM DDR DIMM memory expansion kits.
Standard Memory Plus Optional MemoryStandard Memory Plus Optional Memory
Up to 5120-MB of DDR SDRAM DIMM memory is available with the installation of optional DDR SDRAM DIMM memory expansion
kits.
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional Memory
Standard Memory Replaced with Optional MemoryStandard Memory Replaced with Optional Memory
Up to 8192-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional
DDR SDRAM DIMM memory expansion kits.
(non-condensing)(non-condensing)
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE:
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Height
Width
Depth
Rated input voltage
Rated input current
Rated input Power
Rated input voltage
Rated input current
Rated input Power
Operating
Non-Operating
Operating
Non-Operating
Operating
Non-Operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
10.5 in (26.67 cm)
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC
62.5 A at -48 VDC
3000 W
-43 VDC to -53 VDC
6.25 A at -48 VDC
300 W
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Nominal -48 VDC
Nominal -48 VDC
HP BladeSystem
HP BladeSystem
HP BladeSystemHP BladeSystem
p-Class Server Blade
p-Class Server Blade
p-Class Server Bladep-Class Server Blade
Enclosure with enhanced
Enclosure with enhanced
Enclosure with enhancedEnclosure with enhanced
backplane components
backplane components
backplane componentsbackplane components
Dimensions
Dimensions
DimensionsDimensions
Input Specifications
Input Specifications
Input SpecificationsInput Specifications
Individual Server Blade
Individual Server Blade
Individual Server BladeIndividual Server Blade
Bay Ratings
(non-condensing)(non-condensing)
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE:
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Height
Width
Depth
Rated input voltage
Rated input current
Rated input Power
Rated input voltage
Rated input current
Rated input Power
Operating
Non-Operating
Operating
Non-Operating
Operating
Non-Operating
10.5 in (26.67 cm)
17.60 in (44.70 cm)
28.86 in (73.30 cm)
-43 VDC to -53 VDC
125 A at -48 VDC
6000 W
-43 VDC to -53 VDC
14.6 A at -48 VDC
700 W
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Nominal -48 VDC
Nominal -48 VDC
DA - 12160 North America — Version 7 — June 27, 2005
Page 37
QuickSpecs
Technical Specifications
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for RJ-45
Specifications for RJ-45
Specifications for RJ-45Specifications for RJ-45
Patch Panel 2 with Fiber
Patch Panel 2 with Fiber
Patch Panel 2 with FiberPatch Panel 2 with Fiber
Channel pass through
Channel pass through
Channel pass throughChannel pass through
Dimensions
Dimensions
DimensionsDimensions
Capability
Capability
CapabilityCapability
Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Fiber Channel SAN
Fiber Channel SAN
Fiber Channel SANFiber Channel SAN
Connector
Connector
ConnectorConnector
Cable Support
Cable Support
Cable SupportCable Support
EMI
EMI
EMIEMI
NOTE:
NOTE:
NOTE: NOTE:
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
100 Base-TX
1000 Base-TX
Fiber Channel
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
10.405 in (26.43 cm)
1.535 in (3.899 cm)
27.697 in (70.35 cm)
10 Mbps
20 Mbps
100 Mbps
200 Mbps
1000 Mbps
Auto-rate negotiate between 2G and 1G
RJ-45 in the back.
Pluggable SFP optical slot in the front.
Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)
Category 5 UTP (2 pair); up to 328 ft/100 m
Category 5E (4 pair); up to 328 ft (100 m)
SFP optical cable
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for RJ-45
Specifications for RJ-45
Specifications for RJ-45Specifications for RJ-45
Patch Panel
Patch Panel
Patch PanelPatch Panel
Dimensions
Dimensions
DimensionsDimensions
Capability
Capability
CapabilityCapability
Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Connector
Connector
ConnectorConnector
Cable Support
Cable Support
Cable SupportCable Support
Power Requirements
Power Requirements
Power RequirementsPower Requirements
Temperature Range
Temperature Range
Temperature RangeTemperature Range
DA - 12160 North America — Version 7 — June 27, 2005
(non-condensing)(non-condensing)
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for ProLiant
Specifications for ProLiant
Specifications for ProLiantSpecifications for ProLiant
BL p-Class GbE
BL p-Class GbE
BL p-Class GbEBL p-Class GbE
Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
NOTE:
NOTE:
NOTE: NOTE:
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight
Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode
MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses
Forwarding Table
Forwarding Table
Forwarding TableForwarding Table
Age Time
Age Time
Age TimeAge Time
Memory
Memory
MemoryMemory
Compliance
Compliance
ComplianceCompliance
Network Transfer Rate
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Connector
Connector
ConnectorConnector
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Operating
Non-operating
Operating
Non-operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Height
Width
Depth
11.5 lb/5.2 kg per interconnect switch
9.6 Gbps external port bandwidth per server blade enclosure (full duplex)
Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per
gigabit port, (64-byte packets)
Non-blocking, full-wire speed for all connections
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
8,191 per interconnect switch; MAC address based filtering and MAC
address packet priority configuring
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch
IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D,
802.1p, 802.3ac, 802.3ad (Static), and 802.1Q
SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC
(non-condensing)(non-condensing)
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
NOTE:
NOTE:
NOTE: NOTE:
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
UL/CUL Listed Accessory
CE
-48VDC: 1050 mA, 50 W maximum (per interconnect switch)
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for GbE2
Specifications for GbE2
Specifications for GbE2Specifications for GbE2
Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight
Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode
MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses
Forwarding Table
Forwarding Table
Forwarding TableForwarding Table
Age Time
Age Time
Age TimeAge Time
Memory
Memory
MemoryMemory
Compliance
Compliance
ComplianceCompliance
Height
Width
Depth
12.0 lb/5.4 kg per interconnect switch
24 Gbps External port bandwidth per server blade enclosure (full duplex)
Forwarding rate 1.5 million pps per gigabit port (64-byte packets)
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
2,048 per interconnect switch
Maximum age: 1 to 65535 seconds; default: 300 seconds
128MB Main, 32MB flash and 2MB packet buffer per interconnect switch
IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D,
NOTE: NOTE:
sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit)
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
UL/CUL Listed Accessory
CE
48VDC: 2040 mA, 98 W maximum (per interconnect switch without Storage
Connectivity Kit)
48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage
Connectivity Kit)
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
10 Mbps
20 Mbps
100 Mbps
200 Mbps
2000 Mbps
2000 Mbps
50° to 95° F (10° to 35° C)
-22° to 140° F (-30° to 60° C)
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for CGESM
Specifications for CGESM
Specifications for CGESMSpecifications for CGESM
Interconnect Switch
Interconnect Switch
Interconnect SwitchInterconnect Switch
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight
Performance
Performance
PerformancePerformance
Forwarding Mode
Forwarding Mode
Forwarding ModeForwarding Mode
MAC Addresses
MAC Addresses
MAC AddressesMAC Addresses
Memory
Memory
MemoryMemory
DA - 12160 North America — Version 7 — June 27, 2005
Height
Width
Depth
11.5 lb/5.2 kg per interconnect switch
28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum
Forwarding Rate (64 Byte Packets)
9018Bytes Jumbo Frames MTU
Non-blocking architecture. Wire Speed Performance on all ports
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Store and forward
8000 MAC/physical address Table Size
128MB DRAM Memory. 16MB Flash Memory
10.405 in (26.43 cm)
1.6 in (4.06 cm)
28 in (71.12 cm)
Page 41
QuickSpecs
Technical Specifications
Compliance
Compliance
ComplianceCompliance
Network Transfer
Network Transfer
Network TransferNetwork Transfer
Rate
Rate
RateRate
Connector
Connector
ConnectorConnector
EMI
EMI
EMIEMI
Safety
Safety
SafetySafety
Power
Power
PowerPower
Requirements
Requirements
RequirementsRequirements
Temperature
Temperature
TemperatureTemperature
Range
Range
RangeRange
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
NOTE: NOTE:
sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for
Specifications for
Specifications forSpecifications for
Power Enclosures
NOTE: NOTE:
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Operating
Non-operating
Operating
Non-operating
Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
Height
Width
Depth
No Hot-Plug
Power Supplies
All Hot-Plug
Power Supplies
Rated input voltage
Rated input frequency
Rated input current
per side
Rated input power
per side
Power cord
Rated output voltage
Rated output current
Rated output power
Nominal power
Operating
NOTE
NOTE
)
NOTENOTE
Shipping
Operating
)
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
Non-operating
Operating
Non-operating
20% to 80%
5% to 95%
82.4° F (28° C)
101.7° F (38.7° C)
Single-Phase Model
Single-Phase Model
Single-Phase ModelSingle-Phase Model
5.25 in (13.34 cm)5.25 in (13.34 cm)
27.15 in (68.96 cm)27.15 in (68.96 cm)
17.60 in (44.7 cm)17.60 in (44.7 cm)
47.5 lb (21.55 kg)47.5 lb (21.55 kg)
99.5 lb (45.13 kg)
200 VAC to 240 VAC200 VAC to 240 VAC
50 Hz to 60 Hz50 Hz to 60 Hz
24A
5760 W9976 W
1 NEMA L6-30P per
side
-48.8 VDC to -54 VDC -48.8 VDC to -54 VDC
99A
4298 W8310 W
4158 W at 208 VAC7202 W at 208 VAC
50° to 95° F
(10° to 35° C)
-22° to 140° F
(-30° to 60° C)
20% to 80%20% to 80%
5% to 95%5% to 95%
82.4° F (28° C)82.4° F (28° C)
101.7° F (38.7° C)101.7° F (38.7° C)
Three-Phase Model
Three-Phase Model
Three-Phase ModelThree-Phase Model
125.5 lb (56.93 kg)
line to line
24A per phase
1 NEMA L15-30 per
side
170A
50° to 95° F
(10° to 35° C)
-22° to 140° F
(-30° to 60° C)
DA - 12160 North America — Version 7 — June 27, 2005
Page 43
QuickSpecs
Technical Specifications
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for
Specifications for
Specifications forSpecifications for
Power Distribution
Power Distribution
Power DistributionPower Distribution
Devices
Devices
DevicesDevices
Power
Power
PowerPower
Enclosures or facility DC
Enclosures or facility DC
Enclosures or facility DCEnclosures or facility DC
feeds Supported
feeds Supported
feeds Supportedfeeds Supported
(3U each)
Server blade enclosures
Server blade enclosures
Server blade enclosuresServer blade enclosures
supported
supported
supportedsupported
(6U each)
Total rack height of
Total rack height of
Total rack height ofTotal rack height of
supported enclosures
Total Max Input CurrentTotal Max Input Current
At Minimum Voltage
At Minimum Voltage
At Minimum VoltageAt Minimum Voltage
Total Max Input Current
Total Max Input Current
Total Max Input CurrentTotal Max Input Current
At Nominal Voltage
At Nominal Voltage
At Nominal VoltageAt Nominal Voltage
Max Current Per Power
Max Current Per Power
Max Current Per PowerMax Current Per Power
Feed
Feed
FeedFeed
Max Local Ambient
Max Local Ambient
Max Local AmbientMax Local Ambient
Temperature
Temperature
TemperatureTemperature
NOTE:
NOTE:
NOTE: NOTE:
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Power Bus Box
Power Bus Box
Power Bus BoxPower Bus Box
112
135
9U
5.1 in (12.95 cm)
3.6 in (9.14 cm) each
3.25 in (8.26 cm)
3.62 lb (1.64 kg)
-43.2 VDC to -54 VDC-43.2 VDC to -54 VDC -43.2 VDC to -54 VDC
3000 W9000 W
69.44 A at -43.2VDC
62.5 A at -48VDC
70A70A
149° F (65° C)149° F (65° C)149° F (65° C)
All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds.
Mini Bus Bar
Mini Bus Bar
Mini Bus BarMini Bus Bar
21U36U
19.45 in (49.40 cm)
19.74 in (50.14 cm)19.74 in (50.14 cm)
2.2 in (5.59 cm)2.2 in (5.59 cm)
13.2 lb (5.9 kg)
208.32 A at -43.2 VDC
187.5 A at -48 VDC312.5 A at -48 VDC
Scalable Bus Bar
Scalable Bus Bar
Scalable Bus BarScalable Bus Bar
48.57 in (123.37 cm)
26 lb (11.79 kg)
15000 W
347.2 A at -43.2 VDC
(equivalent of 175A per
feed)
(equivalent of 175A per
feed)
210A
Operating and
Operating and
Operating andOperating and
Performance
Performance
PerformancePerformance
Specifications for
Specifications for
Specifications forSpecifications for
Facility DC
Facility DC
Facility DCFacility DC
Voltage
Voltage
VoltageVoltage
Nominal input voltage
Operating voltage range
Max Input voltage slew
rate
Redundant feed voltages*
(A & B)
Ripple/Noise
Overshoot
Voltage transients
DA - 12160 North America — Version 7 — June 27, 2005
-48 VDC
-48VDC ± 10% or -43.2 VDC to -52.8 VDC
0.5V/uS
*A and B feeds must differ by no more than
5VDC during steady state operation
480 mV PARD**
Must remain within regulation limits on all feeds
during startup or shutdown
Must not exceed -60 VDC
Page 44
QuickSpecs
Technical Specifications
Current
Current
CurrentCurrent
In-rush current
In-rush current
In-rush currentIn-rush current
Input over-current
Input over-current
Input over-currentInput over-current
Max Input Current Slew
Max Input Current Slew
Max Input Current SlewMax Input Current Slew
Rate
Rate
RateRate
Max Rated Power
Max Rated Power
Max Rated PowerMax Rated Power
Connections and Cables
Connections and Cables
Connections and CablesConnections and Cables
NOTE:
NOTE:
NOTE: NOTE:
feeds.
** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured
at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz
frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed
to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF
ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the
current. The printed wiring board assembly is installed in its enclosure for this measurement, or the
measurement leads are properly shielded with Earth grounds applied to the insert.
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
Max steady state input
current
Max steady state current
per feed/total
Power bus boxes
Mini bus bars
Scalable bus bars
Must support up to 2X the maximum operating current per server blade
enclosure (125 A) for up to 1.0 mS
Customer provided fusing for facility DC feeds that protects the system from
catastrophic over-current within 20 uS. Fuse should sustain all in-rush and
operating currents.
1A/uS
3000W per server blade enclosure
Compaq provided facility DC cable connection kit:
The facility DC connection kit supports the connection of up to four 48VDC, RETURN pairs and ground
The power cable assemblies consist of 1/0AWG, color-coded, flexible cable
rated at 105° C, terminated with bus mating connectors at one end and
unterminated at the other end. The cable length provided enables the
customer to route to a fuse panel within or adjacent to the rack.
*All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B
62.5A per server blade enclosure installed at 48VDC
70 A/70A
210 A/210A
210 A/350A or equivalent of 175A per feed*
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
DA - 12160 North America — Version 7 — June 27, 2005
Page 45
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.