HP 2000fc User Manual

QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array

Overview

The HP StorageWorks 2000fc G2 Modular Smart Array (MSA2000fc) represents the newest Fibre Channel model of the MSA2000 family (which includes the MSA2000i iSCSI and the MSA2000sa SAS connected models), a new generation of HP storage arrays specifically designed for entry-level customers and features the very latest in functionality and technology at highly affordable price points.
The MSA2000fc G2 is a 4 Gb Fibre Channel connected 2U storage area network (SAN) or direct connect solution designed for small to medium size departments or remote locations. The controller-less chassis is offered in two models - one comes standard with twelve 3.5-inch drive bays, the other can accommodate twenty-four Small Form Factor (SFF) 2.5-inch drives. Both are able to simultaneously support enterprise-class SAS drives and archival-class SATA drives. The chassis can have one or two MSA2300fc controllers.
The MSA2000fc G2 is all about the ability to choose the proper configuration to fit individual needs. The user can opt for the 24­drive bay SFF chassis for the highest spindle counts in the most dense form factor, or go for the 12 drive bay LFF model to max out total capacity. Choose a single controller unit for low initial cost with the ability to upgrade later; or decide on a model with dual controllers for the most demanding entry-level situations. Capacity can easily be added when needed by attaching additional drive enclosures. Maximum raw capacity ranges with LFF drives from 5.4 TB SAS or 12 TB SATA in the base chassis, to 27 TB SAS or 60 TB SATA with the addition of the maximum number of drive enclosures. Configurations utilizing the SFF drive chassis can grow from twenty-four to a total of ninety-nine SFF drives. The MSA2300fc has been fully tested up to 64 hosts.
hidden charges, licenses or fees as you add enclosures or hosts and users.
NOTE:
NOTE:
There are no additional
NOTE:NOTE:
The MSA2000fc G2 is a member of HP StorageWorks Modular Smart Array offerings, delivering simple and affordable storage technology to meet today's demanding and growing IT needs. These storage solutions offer excellent price/performance and availability features for direct attach configurations, clusters, workgroups and entry-level SAN environments. Each solution is designed to be easy to deploy, to be secure, and with low management costs, while driving rapid return on investment.
What's New
What's New
What's NewWhat's New
Support for Small Form Factor (SFF) SAS and SATA drives, common with ProLiant Support for attachment of THREE dual I/O MSA70 SFF JBODs (ninety-nine) SFF drive Increased support to FOUR MSA2000 LFF disk enclosures with the MSA2312fc (sixty LFF drives) Increased optional snapshot capability to 255 snaps Additional LUN support up to 512 total volumes in a Dual Controller system Adding support for HP-UX, OpenVMS, and Integrity servers Optional DC-power chassis
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 1
QuickSpecs
Overview
Models
Models
ModelsModels
StorageWorks 2000fc G2
StorageWorks 2000fc G2
StorageWorks 2000fc G2StorageWorks 2000fc G2 Modular Smart Array
Modular Smart Array
Modular Smart ArrayModular Smart Array
Controller-less CHASSIS & MSA2300fc G2 FC Controller
Controller-less CHASSIS & MSA2300fc G2 FC Controller
Controller-less CHASSIS & MSA2300fc G2 FC ControllerController-less CHASSIS & MSA2300fc G2 FC Controller HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF)
(Will accept one or two controllers or Disk Enclosure I/O modules) HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF)
(Will accept one or two controllers) HP StorageWorks 2300fc G2 Modular Smart Array Controller Configured Units
Configured Units
Configured UnitsConfigured Units HP StorageWorks 2312fc G2 Dual Controller Modular Smart Array (LFF)
(Pre-configured with two array controllers) HP StorageWorks 2324fc G2 Dual Controller Modular Smart Array (SFF)
(Pre-configured with two array controllers) MSA2300fc SAN Starter Kits
MSA2300fc SAN Starter Kits
MSA2300fc SAN Starter KitsMSA2300fc SAN Starter Kits HP StorageWorks 2312fc G2 Single Controller Modular Smart Array SAN Starter Kit
(includes single controller, 12-drive bay LFF array head, 8-port 8Gb switch, two 8Gb HBAs, SFPs and cables)
HP StorageWorks 2324fc G2 Single Controller Modular Smart Array SAN Starter Kit (includes single controller, 24-drive bay SFF array head, 8-port 8Gb switch, two 8Gb HBAs, SFPs and cables)
HP StorageWorks 2300fc G2 Modular Smart Array SAN Starter HA Upgrade Kit (includes additional single controller, 8-port 8Gb switch, two more 8Gb HBAs, SFPs and cables) For upgrading AJ954A or AJ955A to dual controller, high availability configurations
Controller-less Chassis: DC-powered units
Controller-less Chassis: DC-powered units
Controller-less Chassis: DC-powered unitsController-less Chassis: DC-powered units HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis
(LFF) (can add one or two MSA2300fc G2 controllers or MSA2000 JBOD I/O modules)
HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) (can add one or two MSA2300fc G2 controllers. No MSA2000 JBOD I/O module support)
Disk Enclosures
Disk Enclosures
Disk EnclosuresDisk Enclosures
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2324fc Modular Smart Array
HP StorageWorks 2324fc Modular Smart Array
HP StorageWorks 2324fc Modular Smart ArrayHP StorageWorks 2324fc Modular Smart Array
StoraageWorks 2312fc Modular Smart Array
StoraageWorks 2312fc Modular Smart Array
StoraageWorks 2312fc Modular Smart ArrayStoraageWorks 2312fc Modular Smart Array
AJ948A
AJ949A
AJ798A
AJ795A
AJ797A
AJ954A
AJ955A
AJ956A
AJ950A
AJ951A
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 2
QuickSpecs
Overview
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks MSA2000 Single I/O 3.5-inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with single controller array head
HP StorageWorks MSA2000 Dual I/O 3.5-inch inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with dual controller array head
HP StorageWorks MSA2000 Drive Enclosure I/O Module (no cable included)
HP StorageWorks MSA70 2.5-inch 25 SFF Drive Enclosure 2.5 in Drive Enclosure (single I/O, single domain) (w/one .5m miniSAS to miniSAS cable)
HP StorageWorks Dual Domain I/O Module for MSA70 enclosure (upgrades MSA70 to dual domain) (w/ one .5m miniSAS to miniSAS cable)
Related Option
Related Option
Related OptionRelated Option HP StorageWorks 2000fc Modular Smart Array Controller (restricted use)
(for use only with an AJ948A LFF chassis to configure an older MSA2012fc. Only supports older features, functionalities. No SFF support, max 48 LFF drives, max 64 snaps; no HP-UX, OpenVMS, or Integrity server support)
AJ749A
AJ750A
AJ751A
418800-B21
AG779A
AJ744A
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 3
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array

Features and Benefits

Key Hardware Features
Key Hardware Features
Key Hardware FeaturesKey Hardware Features
Highly efficient consolidation and sharing of storage geared to departmental and small to medium business requirements Cost efficient plus high-availability choices Flexibility in drives: LFF MSA2 3.5-inch or HP ProLiant SFF 2.5-inch drives Enterprise-class SAS or archival-class SATA drives as the need and budget dictates Dual-ported SAS drives for enterprise needs Large capacity SATA drives for inexpensive archival storage Able to mix SAS and SATA drives within the same drive enclosure Choose either single or dual controller array models to fit the budget Choice of low cost single I/O or high-availability dual I/O drive enclosure models
Customer Benefits
Customer Benefits
Customer BenefitsCustomer Benefits
The HP StorageWorks 2000 Modular Smart Array family manages growing storage requirements across multiple HP ProLiant, Integrity, and a selection of PA-RISC servers for customers who need a centralized dedicated storage solution for applications. SANs allow for controlled, cost-effective growth and increased protection of data. Its ease of management allows a department or small company to effectively handle growing storage requirements with a minimum of complexity. The MSA2000fc extends the benefits of shared storage resources (e.g. SAN) to first time implementers on a limited budget This new Fibre Channel G2 model introduces support for Integrity servers and the HP-UX and OpenVMS operating systems The modular design allows the user to start relatively small but supports future growth to hundreds of users and up to 27TB of LFF SAS or 60TB of LFF SATA storage, or 14.4TB of SFF SAS or 24TB SFF SATA storage. The optional controller-based snapshot and clone capability of the MSA2000 family allows the smaller departmental user or company to implement functionality once only available to much larger firms with expensive arrays. The MSA2300fc G2 controller supports up to 255 snaps.
HP MSA2300fc Models At a Glance:
HP MSA2300fc Models At a Glance:
HP MSA2300fc Models At a Glance:HP MSA2300fc Models At a Glance:
High performance Modular Smart Array controller(s), each with two 4Gb Fibre Channel ports Single or dual controller capability 1 GB transportable cache per controller - battery-free cache backup with super capacitors and compact flash 512 LUNs with 16TB LUNs supported 2U rack mount chassis combining both the controller and disk shelf Twelve 3.5-inch or twenty-four 2.5-inch dual-ported SAS or SATA drive bays (supports mixing of drive types in a single shelf) Supports expansion to 4 additional LFF enclosures for a total of 60 LFF disks Supports expansion to 3 additional SFF enclosures (MSA70) for a maximum total of 99 SFF disks Redundant power supplies and fans are standard RAID levels 0, 1, 3, 5, 6, 10, 50 Non-disruptive on-line controller code upgrade (requires dual controllers w/ multi-pathing software) Heterogeneous support for 32-bit and 64-bit Windows, Red Hat and SuSE Linux, HP-UX and OpenVMS Windows Server 2008 x64 Hyper-V, VMware, RedHat Enterprise Linux Virtualization, and Citrix XenServer Qualified and certified for Windows, Linux, HP-UX and OpenVMS clustering Optional controller-based snapshot and clone functionality
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 4
QuickSpecs

Family Information

HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Capacity
Capacity
CapacityCapacity Minimum / with maximum additional drive enclosures
Controller Cache
Controller Cache
Controller CacheController Cache Total LUNs
Total LUNs
Total LUNsTotal LUNs Host connect
Host connect
Host connectHost connect MSA2000 have 1 or 2 controllers, EVA has 2 controllers standard
Maximum Drives
Maximum Drives
Maximum DrivesMaximum Drives w/ expansion
Maximum host supported
Maximum host supported
Maximum host supportedMaximum host supported Snapshot, clone
Snapshot, clone
Snapshot, cloneSnapshot, clone
Use for Storage
Use for Storage
Use for StorageUse for Storage
NOTE:
NOTE:
NOTE:NOTE: LUNs and LUN size.
(raw)
maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of
MSA2000fc G2
MSA2000fc G2
MSA2000fc G2MSA2000fc G2
LFF
LFF
: 5.4 TB SAS
LFFLFF
or 12 TB SATA
w/ 4 drive enclosures:
27 TB SAS
or 60 TB SATA
SFF
SFF
: 3.5 TB SAS
SFFSFF
or 2.8 SATA
w/ 3 MSA70 JBODs:
14.4 TB SAS
or 11.8 TB SATA
1 GB per controller 1 GB per controller 1 GB per controller 2 GB per controller
512 256 256
Two 4 Gb
Fibre Channel ports
per controller
60 LFF/99 SFF
64 16
Snapshot (max 255)
clone
Primary Storage
with SAS.
Secondary with SATA
MSA2000i
MSA2000i
MSA2000iMSA2000i
5.4 TB SAS
or 12 TB SATA
w/ 3 drive enclosures:
21.6 TB SAS
or 48 TB SATA
(LFF only)
Two 1 GbE
iSCSI ports
per controller
48 48 96
Snapshot (max 64)
clone
Primary Storage
with SAS.
Secondary with SATA
MSA2000sa
MSA2000sa
MSA2000saMSA2000sa
5.4 TB SAS
or 12 TB SATA
w/ 3 drive enclosures
21.6 TB SAS
or 48 TB SATA
(LFF only)
Two 3 Gb
SAS ports
per controller
4
Snapshot (max 64)
clone
Primary Storage
with SAS.
Secondary with SATA
Comparison w/
Comparison w/
Comparison w/Comparison w/
EVA4400
EVA4400
EVA4400EVA4400
5.4 TB FC
or 12 TB FATA
w/ 8 drive enclosures
43 TB FC
or 96 TB FATA
(LFF only)
1024
Two 4 Gb
Fibre Channel ports
per controller
(Ten w/switch)
Snapshot, clone,
remote data replication
Primary Storage
with FC
Secondary with FATA
512
Product Technology
Product Technology
Product TechnologyProduct Technology
4 Gb Fibre Channel
4 Gb Fibre Channel
4 Gb Fibre Channel4 Gb Fibre Channel technology
technology
technologytechnology
Modular Chassis
Modular Chassis
Modular ChassisModular Chassis
Drives available
Drives available
Drives availableDrives available
DA - 13187 EMEA — Version 2 — February 10, 2009
Two host ports per controller, shipped with SFPs. the MSA2000fc G2 controller can run in either point-to-point or FCAL (loop). The default is FCAL which is used in Direct Connect, particularly with two controllers. The PtP (fabric) mode is used with almost all switches.
2U rack height. 12 Large Form Factor or 24 Small Form Factor drive bays, accommodating SAS and SATA. Comes with space for one or two controllers, or MSA2000 3.5-inch disk Enclosure I/O modules (LFF chassis only)
The new MSA2000fc G2 controller supports either the MSA2 3.5-inch Large Form Factor (LFF) drives, or the HP ProLiant 2.5-inch Small Form Factor (SFF) drive Serial Attached SCSI (SAS) enterprise-class drives designed for high volume, 24x7 usage. Serial-ATA (SATA) are usually reserved for archival of data as they are both relatively inexpensive and are available in very large capacities. The MSA2000 family of arrays can accommodate both SAS and SATA drives within the same enclosure making it ideal to have both business-critical, high activity files on SAS drives while using Snapshot or clone capability to keep back-up or archival data on the less expensive drives. For investment protection, the MSA2300fc G2 controller will support single
Page 5
QuickSpecs
Family Information
Optional Disk enclosures
Optional Disk enclosures
Optional Disk enclosuresOptional Disk enclosures
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
port SAS & SATA drives in a single-domain MSA70. This support allows current owners of MSA70s to migrate their single port drives (in their MSA70 only) to be attached to an MSA2300fc. They can only cascade to another single I/O MSA70. This is not a data-in-place transition. SAS drive performance can be approximately 30% greater than SATA performance on sequential host I/O. SAS performance excels in sequential lower latency response time and random I/O per second transaction performance due to higher rpm disk speeds yielding lower seek times. SAS drive random performance is generally twice that of SATA drives.
NOTE:
NOTE:
MSA2 3.5-inch Large Form Factor (LFF) drives are for use only in the
NOTE:NOTE: MSA2000 family. The 2.5-inch Small Form Factor (SFF) drives are supported only with the MSA2300fc G2 controller and are common with and are the same part numbers as the ProLiant optional 2.5-inch drives.
Just as the user has a choice of chassis for the array head (LFF and SFF drive bays), so also do they have a choice of expansion disk enclosures accommodating either drive size.
MSA2000 3.5-inch drive enclosure
MSA2000 3.5-inch drive enclosure
MSA2000 3.5-inch drive enclosureMSA2000 3.5-inch drive enclosure drive bays and accepts for MSA2 dual-ported SAS and SATA drives. One model (AJ749A) has a single I/O module that matches with a single controller array head, giving a single path to the drives. The second model (AJ750A) comes standard with two I/O modules installed, required when paired with a dual controller array head, giving two paths to the drives for higher availability.
. This 2U unit has twelve LFF (3.5-inch)
This 3.5-inch drive enclosure can be attached to either the MSA2312fc or MSA2324fc array head. In addition it continues to support the MSA2000i and MSA2000sa. Each model ships standard with two .6m SAS to SAS cables for cascading to other MSA2000 drive enclosures For connection to either form-factor MSA2300fc array head, miniSAS to SAS cable(s) must be purchased. The single I/O model can be upgraded to a dual model with the purchase of an additional MSA2000 Drive Enclosure I/O module (AJ751A). No cable is included with this upgrade. Up to four MSA2000 3.5-inch enclosures can be attached to an MSA2300fc G2 controller in the array head.
MSA70 2.5-inch drive enclosure
MSA70 2.5-inch drive enclosure
MSA70 2.5-inch drive enclosureMSA70 2.5-inch drive enclosure designed to support twenty five ProLiant 2.5-inch Universal form factor (SFF) SAS or SATA hard drives. It ships standard with a single I/O module installed.
This 2.5-inch drive enclosure can only be attached to an MSA2324fc G2 controller (SFF)array head. It cannot be attached to the MSA2312fc (LFF) or the MSA2000i or MSA2000sa models. The MSA70 enclosure ships with a single .5m miniSAS to miniSAS cable. To support a dual controller MSA2124fc array head, the user needs to purchase and install an MSA70 Dual Domain I/O Module (AG779A). This option ships standard with an additional .5m miniSAS to miniSAS cable. Up to three MSA70s may be attached to the array head, given total support for 99 SFF drives.
. This 2U storage enclosure (418800-B21) is
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 6
QuickSpecs
Family Information
Scalability
Scalability
ScalabilityScalability
LUNs
LUNs
LUNsLUNs
RAID 0, 1, 3, 5, 6, 10,
RAID 0, 1, 3, 5, 6, 10,
RAID 0, 1, 3, 5, 6, 10,RAID 0, 1, 3, 5, 6, 10, 50
50
5050
Performance
Performance
PerformancePerformance
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
The MSA2300fc G2 controller is designed to allow an installation to begin with smaller capacity and be able to grow gradually as needed. The flexibility of SAS or SATA drive technology, form factors, sizes, speeds, and costs per GB allows a system to easily fit in almost any budget.
Large Form Factor configurations can scale up to 5.4 TB SAS or 12 TB SATA, expandable to 27 TB SAS or 60 TB SATA with the addition of a maximum of four MSA2000 3.5-inch Drive Enclosures. Small Form Factor configurations can scale from 3.5 TB SAS or 6 TB SATA. With the addition of three MSA70 JBODs, the MSA2324fc G2 can support 14.4 TB SAS or 24.7 TB SATA. Users may configure a 24-drive MSA2324fc G2 SFF array head with up to three 12-drive LFF MSA2000 3.5-inch disk enclosures. This is an excellent method for a configuration that support fast SFF enterprise­class SAS drives in the array head, combined with economical LFF drives staged for archival purposes, all in the same array. Qualification of larger capacity drives is ongoing.
The MSA2000 family of arrays supports 512 LUNs (total volumes in a dual controller system) and LUN sizes up to 16 TB. The array supports expansion and deletion of any LUN.
In addition to the usual RAID levels, the MSA2000 family features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes.
Performance numbers are a guideline as established by tests in a lab environment. 96 72 GB 15K SAS drives were used in dual controller configurations of eight 12 Disk vdisks, eight 806 GB volumes, and two volumes per host.
Number and type of applications along with the number of hosts will affect overall performance.
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 7
QuickSpecs
Family Information
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
DC-power chassis
DC-power chassis
DC-power chassisDC-power chassis
Configuration and
Configuration and
Configuration andConfiguration and Management Tools
Management Tools
Management ToolsManagement Tools
Hot Plug Expansion and
Hot Plug Expansion and
Hot Plug Expansion andHot Plug Expansion and Replacement Support
Replacement Support
Replacement SupportReplacement Support
Snapshot and Clone
Snapshot and Clone
Snapshot and CloneSnapshot and Clone
Workload
Host Connect
MSA2000 RAID 10 Performance Results (rounded)
MSA2000 RAID 10 Performance Results (rounded)
MSA2000 RAID 10 Performance Results (rounded)MSA2000 RAID 10 Performance Results (rounded) Random Reads IOPs Random Writes IOPs Random Mix IOPs 60/40
read/write Sequential Reads MB Sequential Writes MBs MSA2000 RAID 5 Performance Results (rounded)
MSA2000 RAID 5 Performance Results (rounded)
MSA2000 RAID 5 Performance Results (rounded)MSA2000 RAID 5 Performance Results (rounded) Random Reads IOPs Random Writes IOPs Sequential Reads MBs Sequential Writes MBs Random Mix IOPs
60/40 read/write MSA2000 RAID 6 Performance Results (rounded)
MSA2000 RAID 6 Performance Results (rounded)
MSA2000 RAID 6 Performance Results (rounded)MSA2000 RAID 6 Performance Results (rounded) Random Reads IOPs Random Writes IOPs Sequential Reads MBs Sequential Writes MBs Random Mix IOPs 60/40
read/write
HP is making the two models of controller-less chassis available with direct current (DC) power supplies. They each have the two empty bays where users can insert one or two MSA2300fc G2 controller(s). In addition, the MSA2012 LFF drive bay can have MSA2000 3.5-inch I/O modules inserted to create a LFF DC-power JBOD. The 500 watt power supply is designed to operate over the input range of ­40VDC to -75VDC. This is specifically intended to conform to Telco requirements. Certification is in process but no claims are made at this time.
HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF)
HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF)
HP StorageWorks MSA Storage Management Utility (SMU). Management access, out-of-band: WEB GUI, CLI. Interface Types: Mini DB9 RS232, 10/100 Ethernet Protocols Supported SNMP, SSL, SSH, SMTP, HTTP, Telnet
All MSA2000 models support hot plug expansion and replacement of redundant controllers, enclosures, fans, power supplies, and I/O modules for simple, fast installation and maintenance.
Optional controller based functionality. Offers higher levels of data protection, enabling an almost instant recovery from data failure or corruption. Offers alternative development testing of 'offline' production data and the ability to backup snapped/cloned data.
MSA2300fc
4 Gb Fibre
Channel
21,400 10,600
8,800 4,900 4,500
13,500
1,300
560 350 260
20,500 10,200
2,400 2,000 1,600 1,300
780 380 270
5,900 3,300 3,200
20,500 10,100
1,600 1,400 1,200 1,300
820 380 270
4,500 2,750 2,560
MSA2000sa
3 Gb SAS
6,800 6,100
700 300
700 300
700 300
MSA2000i
1GbE Ethernet
8,200
7,800
7,800
AJ950A
AJ951A
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 8
QuickSpecs
Family Information
Overview
Overview
OverviewOverview
Server Compatibility
Server Compatibility
Server CompatibilityServer Compatibility
Industry Standard X86
Industry Standard X86
Industry Standard X86Industry Standard X86 servers support
servers support
servers supportservers support
OS Support (x86)
OS Support (x86)
OS Support (x86)OS Support (x86)
OS Support
OS Support
OS SupportOS Support (Integrity, HP9000)
(Integrity, HP9000)
(Integrity, HP9000)(Integrity, HP9000)
Web Browser support
Web Browser support
Web Browser supportWeb Browser support
The MSA2000fc G2 comes integrated with web browser based software for storage and RAID management, setup, configuration and troubleshooting. This reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP storage solution.
Supports most HP ProLiant and Integrity servers including
HP ProLiant DL, ML HP ProLiant c-Class Blade Servers Integrity servers, IA64 & PA Risc
Supports most multi-vendor industry standard 32-bit Intel and AMD based (x86) servers. HP requires the Third-Party Server to be logo'd and listed on the Microsoft Windows Server Catalog. Refer to the Microsoft website: HP StorageWorks Division recommends that the Third-Party Server Vendor is an active member of TSANet. Refer to the TSANet website for details:
Microsoft Windows Server 2008 IA32 (Standard, Enterprise, Datacenter) Microsoft Windows Server 2008 x64 (Standard, Enterprise, Datacenter) Microsoft Windows 2003 and 2003 R2 Microsoft Windows 2003 X64 Red Hat Linux 4 & 5 (32/64) SuSE SLES 9 & 10 (32/64) Microsoft Windows Server 2008 x64 Hyper-V VMware ESX 3.0.1, 3.0.2, 3.5 Integrated Citrix XenServer HP Enterprise. Citrix Xen Enterprise 4.1.0-7846 (AMD64, EMT64)
HP-UX V3 Integrity, HP9000 HP-UX V2 Integrity, HP9000 OpenVMS 8.3. OpenVMS 8.3-1H1
MSA2000 support target based management, and includes a Web interface and a telnet interface, and requires a web browser for management. Only Microsoft Internet Explorer V6.X and above, and Mozilla Firefox 1.0.7 or later are supported
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
http://www.microsoft.com/windows/catalog/server/
www.tsanet.com
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 9
QuickSpecs

Optional Software

MSA2300 Snapshot and
MSA2300 Snapshot and
MSA2300 Snapshot andMSA2300 Snapshot and Volume Copy Software
Volume Copy Software
Volume Copy SoftwareVolume Copy Software
Path failover (MPIO)
Path failover (MPIO)
Path failover (MPIO)Path failover (MPIO)
Product Features
Product Features
Product FeaturesProduct Features Data Protection
Data Protection
Data ProtectionData Protection
Snapshots create up to 255 point-in-time pictures of data Volume Copies create up to 128 point-in-time copies of data Recovery is instant - revert data from any previous Snapshot or Volume Copy Backup 'snapped' data to disk, virtual tape, or physical tape without a backup window
Data Testing
Data Testing
Data TestingData Testing
Snap or clone data to test the performance of a software application on 'offline' production data Snap or clone data to test how a software patch or enhancement will function on 'offline;
production data HP StorageWorks 2000 Modular Smart Array Snapshot 255 Software LTU HP StorageWorks 2000 Modular Smart Array Snapshot 64 Software LTU HP StorageWorks 2000 Modular Smart Array Snapshot 8 Software LTU HP StorageWorks 2000 Modular Smart Array Snapshot 8/255 Upgrade Software
1
LTU HP StorageWorks 2000 Modular Smart Array Snapshot 64/255 Upgrade Software
1
LTU HP StorageWorks 2000 Modular Smart Array Snapshot 8 to 64 Upgrade Software
LTU HP StorageWorks 2000 Modular Smart Array Volume Copy Software LTU
1
The snapshot software is supported on the MSA2324 and MSA2312 (G2) models
only
MPIO Basic Failover for Windows provides a single multi-path solution for HP StorageWorks MSA2000fc Modular Smart Array on HP ProLiant servers by providing basic path failover. Supports Windows 2003, Windows 2003 R2, and Windows 2003 X64 operating systems.
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
1
T5539A T5512A T5513A T5540A
T5541A
T5515A
T5514A
HP StorageWorks Storage
HP StorageWorks Storage
HP StorageWorks StorageHP StorageWorks Storage Mirroring
Mirroring
MirroringMirroring
HP MPIO Full Featured DSM for MSA2000fc v2.2.0.22
Microsoft Windows 2008: Microsoft MPIO is bundled with Windows Server 2008 and must be
installed as an operating system feature.
Failover support for Linux is with Device Mapper 4.0.
HP-UX PV-Links
Xen: Inbox Device Mapper
HP StorageWorks Storage Mirroring Software provides host-based, continuous replication for customers seeking a low-cost alternative to fabric or array-based replication. Patented replication and failover technology continuously captures byte-level data changes as they happen and replicates those changes to one or more target servers at any location without geographic limitations. By replicating only the bytes that change, Storage Mirroring Software uses the absolute minimum bandwidth on your existing LAN or WAN to replicate your data. Storage Mirroring also provides server failover where a production server can automatically be 'replaced' by the storage mirroring server in the event of failure. Couple Storage Mirroring with MSA2000 Snapshots and/or Volume Copy to achieve an Enterprise class data protection strategy creating different data recovery points using continuous data protection with Storage Mirroring and point-in-time data protection with Snapshots and/or Volume Copy. Storage Mirroring Software supports:
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 10
QuickSpecs
Optional Software
Any DAS, NAS, and SAN storage device.
Any Windows or Linux ProLiant server including all ML, DL, and BL platforms
Many Windows platforms including Windows Server 2000, Windows Server 2003, Windows
Server 2003 R2, Windows Storage Server 2003, Windows Storage Server 2003 R2, 64bit
Windows, and Windows on Itanium
Some Linux platforms including Red Hat Linux Enterprise 4.4-4.6, 5.x
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
For more information visit HP StorageWorks Storage Mirroring Software Windows Server Edition 1 LTU HP StorageWorks Storage Mirroring Software Windows Enterprise Server Edition 1
LTU HP StorageWorks Storage Mirroring Software Windows NAS Edition 1 LTU HP StorageWorks Storage Mirroring Software for AiO Edition 1 LTU HP StorageWorks Storage Mirroring Software for 5 Virtual Machines 1 LTU HP StorageWorks Storage Mirroring SW Linux 1 LTU HP StorageWorks Storage Mirroring Virtual Infrastructure 1 LTU
NOTE:
NOTE:
For more information visit
NOTE:NOTE:
http://h18006.www1.hp.com/products/storage/software/sm/index.html
HP ProLiant Storage
HP ProLiant Storage
HP ProLiant StorageHP ProLiant Storage Server gateways:
Server gateways:
Server gateways:Server gateways: Add more value to your
Add more value to your
Add more value to yourAdd more value to your MSA array
MSA array
MSA arrayMSA array
Stretch your MSA2000 array investment by adding file & print services, iSCSI connectivity, and management hosting with a ProLiant Storage Server gateway platform. HP ProLiant Storage Servers are optimized file and print server solutions that are built on industry-standard HP ProLiant servers and come with either Microsoft Windows Storage Server 2003 R2 or Windows Unified Data Storage Server 2003 operating system pre-installed. Since they're Windows-based, network integration is easy, your tools and data protection applications run right on the box, and management has a familiar look and feel. Like many Network Attached Storage (NAS) devices, they support heterogeneous file serving environments and are pre-configured to install in minutes. A DL380 G5 x64 SAN Storage Server is a file/iSCSI gateway that adds IP-based services to your Fibre Channel array or SAN. So it not only enhances your MSA investment with file and print services, but it helps you save even more by enabling tiered (Fibre Channel and iSCSI) block access for application servers. All of your important client and server data can be managed, scaled, and protected on a single MSA2000 array.
http://h18006.www1.hp.com/products/storage/software/sm/index.html
T5438A T5440A
T5442A T5446A T5444A T5448A T5450A
NOTE:
NOTE:
For more information visit:
NOTE:NOTE:
HP ProLiant DL380 G5 Base Storage Server
NOTE:
NOTE:
Microsoft Windows Storage Server 2003 R2 Standard x64 Edition O/S with
NOTE:NOTE: file/print services on a 2U rack form factor platform. For more information, go to:
http://h18006.www1.hp.com/products/quickspecs/12559_div/12559_div.html
HP ProLiant DL380 G5 SAN Gateway Storage Server
NOTE:
NOTE:
Microsoft Windows Unified Data Storage Server 2003 Enterprise x64 Edition
NOTE:NOTE: O/S with file/print, iSCSI, and cluster services on a 2U rack form factor platform. For more information, go to:
http://h18006.www1.hp.com/products/quickspecs/12559_div/12559_div.html
HP ProLiant SB460c SAN Gateway Storage Server
NOTE:
NOTE:
Microsoft Windows Unified Data Storage Server 2003 Enterprise x64 Edition
NOTE:NOTE: O/S with file/print, iSCSI, and cluster services on a blade form factor platform. For more information, go to:
http://h18006.www1.hp.com/products/quickspecs/13114_div/13114_div.html
Fibre Channel HBA options for DL380 G5 Storage Servers
Fibre Channel HBA options for DL380 G5 Storage Servers
Fibre Channel HBA options for DL380 G5 Storage ServersFibre Channel HBA options for DL380 G5 Storage Servers
DA - 13187 EMEA — Version 2 — February 10, 2009
http://www.hp.com/go/storageservers
AG815B
AG771B
AN583A
Page 11
QuickSpecs
Optional Software
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks FC2142SR 4Gb PCIe HBA HP StorageWorks FC2242SR Dual Channel 4 Gb PCIe HBA HP StorageWorks FC1142SR 4Gb PCIe HBA HP StorageWorks FC1242SR Dual Channel 4 Gb PCIe HBA HP StorageWorks 81Q PCI-e FC HBA HP 82Q 8Gb Dual Port PCI-e FC HBA HP StorageWorks 81E 8Gb SP PCI-e FC HBA HP 82E 8Gb Dual-port PCI-e FC HBA Fibre Channel HBA options for the SB460c SAN Gateway Storage Server
Fibre Channel HBA options for the SB460c SAN Gateway Storage Server
Fibre Channel HBA options for the SB460c SAN Gateway Storage ServerFibre Channel HBA options for the SB460c SAN Gateway Storage Server Emulex LPe1105 FC Dual Channel 4Gb, PCI-E-to-Fibre Channel Host Bus Adapter QLogic QMH2462 4Gb FC HBA for HP c-Class BladeSystem
A8002A A8003A
AE311A AE312A
AK344A
AJ764A AJ762A AJ763A
403621-B21 403619-B21
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 12
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

Warranty
Warranty
WarrantyWarranty
Three-year limited warranty
Three years parts exchange
Next Business day delivery
Enclosures, Hard drives, and Options for the MSA2000fc carry their own warranty. Refer to HP's Limited Warranty Statement for more information.
The MSA2000fc has been designed with customer self repairable parts to minimize repair time and provide greater flexibility in performing defective parts replacement. Please refer to HP's limited warranty Statement and parts replacement instructions for further details.
http://h18006.www1.hp.com/products/storageworks/warranty.html
Products included in various Kits carry their own individual warranties.
NOTE:
NOTE:
The warranty of the hard drive options purchased with the MSA2000fc product is different for
NOTE:NOTE: SAS hard drives versus SATA hard drives. SAS hard drive options have a three year warranty and SATA hard drives options have a one year warranty.
HP Care Pack Services. Scalable, Flexible, Dependable. Like your storage.
HP Care Pack Services. Scalable, Flexible, Dependable. Like your storage.
HP Care Pack Services. Scalable, Flexible, Dependable. Like your storage.HP Care Pack Services. Scalable, Flexible, Dependable. Like your storage.
Your storage is evolving. Get scalable support that evolves with it. HP Care Pack Services is an easy-to-buy, easy-to-use portfolio of packaged services covering your lifecycle needs. You can rely on our highly skilled, HP certified professionals to offer a breadth of expertise across leading storage technologies, and work side by side with you for optimal results. Push services beyond expectations and choose support that meets the changing needs of your business with the same reliability, scalability and flexibility you demand of your storage.
Protect your business beyond the warranty
Protect your business beyond the warranty
Protect your business beyond the warrantyProtect your business beyond the warranty
Standard warranty protects against product defects and some causes of downtime. HP Care Pack Services helps you proactively guard against unplanned downtime which can reduce your productivity and profitability. By using a standard approach to warranty uplifts, such as HP Care Pack Services, customers can be more sure of consistency of operations for both mission-critical and standard business computing.
Extending warranties with HP Care Pack Services
The key to normalizing the warranty of combined solutions-is making service uplift simple: HP Care Pack Services. This portfolio of predefined packages, extending across the entire IT lifecycle, offering consulting, education, technical support, optimization, risk assessment, and more. It's entirely flexible allowing customers to extend the cover to the precise level of support required. Customer's standard hardware warranty, for example, can be upgraded to next-business-day response, to same-day coverage, or even to a committed six-hour call-to-repair service available 24 hours every day of the week.
Provide consistent, predictable levels of support across your entire department or business Give you direct access to proven technical and problem-solving expertise Offer a choice of response-time and repair-time commitments Are available whenever and wherever you do business
For many products, post-warranty HP Care Pack Services are available when your original warranty has expired. Choose the support levels that meet your business requirements, from basic to mission-critical.
NOTE:
NOTE:
Care Pack Services availability may vary by product and country.
NOTE:NOTE:
DA - 13187 EMEA — Version 2 — February 10, 2009
http://www.hp.com/hps/storage
Page 13
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
Related Services
Related Services
Related ServicesRelated Services
Services that will enhance the user experience in many product deployments
Services that will enhance the user experience in many product deployments
Services that will enhance the user experience in many product deploymentsServices that will enhance the user experience in many product deployments HP SAN Solution Service
HP Data Migration Service
Get your SAN implementation right - right from the start.
Storage has become essential to the growth and agility of your business. That's why choosing an HP SAN as your data management solution is a smart business decision. But your SAN can deliver the results you need only if it is implemented correctly and integrated with your business.
SAN installation, startup, and integration call for specialized expertise in planning and design, hardware configuration, network software installation, and operability verification. Your SAN needs to be configured for high performance and availability. And it needs to be integrated with your applications, management environment, and business processes.
Minimize the risks involved in transferring data to your HP StorageWorks SAN.
You need to move your critical enterprise data to your new HP StorageWorks SAN platform. And you need to accomplish that without losing data. And without interrupting your ongoing business operations.
HP Backup & Recovery Solution Service - ISV
HP Data Migration Service helps you lessen the risk of data loss, minimize threats to data integrity, and avoid productivity-sapping performance slowdowns during data transport. A highly experienced HP Services storage specialist works with you to rapidly and securely migrate mission-critical business information across your data center or around the globe ­regardless of the complexity of your environment.
This service consists of installation of the ISV backup software for the supported SAN environment per HP's and the ISV's quality standards by a trained service specialist. HP Backup and Recovery Solution Service for ISV Backup Software provides for the implementation of the supported ISV backup software in a SAN environment. The two levels of service described here are based on the size and complexity of the backup environment.
This service is available for VERITAS NetBackup, VERITAS Backup Exec, CommVault Galaxy, and Legato NetWorker. Implementation of CommVault Galaxy is only available as a Level 3 service.
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 14
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
eSupport
eSupport
eSupporteSupport
HP eSupport is a portfolio of technology-based services that assist you with managing your business environment - from the desktop to the data center.
Support Portal
Support Portal
Support PortalSupport Portal The HP support portal provides one-stop access to the information, tools and services you need to manage the daily operations of your IT environment. Features include:
Access to self-solve tools (including search technical knowledge base)
Efficient logging and tracking of support cases
Collaboration with other business and IT professionals
Download of patches and drivers
Access to diagnostic tools
Proactive notification of relevant information
Access to certain features of the support portal requires an HP service agreement. To access the support portal, visit:
Remote Support Technology (RST)-HP Remote Support Pack Taking a more proactive approach to IT support, the HP Remote Support pack plug-in module easily integrates with HP Systems Insight Manager to provide a powerful, unified "single pane of glass" solution for onsite and remote management.
http://www.hp.com/support
Customer Technical
Customer Technical
Customer TechnicalCustomer Technical Training
Training
TrainingTraining
HP Services Awards
HP Services Awards
HP Services AwardsHP Services Awards
Additional Services
Additional Services
Additional ServicesAdditional Services Information
Information
InformationInformation
HP Remote Support Pack enhances HP Systems Insight Manager with intelligent event diagnosis plus the automatic submission of hardware event notifications securely to HP support, including acknowledgment and status returns. It adds remote configuration collections to allow the delivery of assessment and proactive services for your SAN storage and HP-UX environments.
Consider education as an integral part of your strategy to get the best return on investment for your HP storage solution. HP offers a variety of training courses on storage software, networking, archiving and disk storage systems. Our classes are available in many delivery modalities from traditional instructor-led courses at one of our 80 training centers worldwide to on-site training customized to your needs or online.
www.hp.com/learn/storage
HP Services continues to be recognized for service and support excellence by customers, partners, industry organizations and publications around the world. Recent honors and award reflect our services team's dedications, technical expertise, professionalism and uncompromising commitment to customer satisfaction. For a list of all our awards, please visit
0-0-225-121.html
For more information about HP Care Pack Services for Storage, please visit:
http://www.hp.com/hps/storage
If you have specific questions, contact your local HP representative. Contact information for a representative in your area can be found at "Contact HP"
.
http://h20129.ww2.hp.com/services/cache/77318-
http://www.hp.com
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 15
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
Warranty Upgrade
Warranty Upgrade
Warranty UpgradeWarranty Upgrade Options
Options
OptionsOptions
Software Product Services
Software Product Services
Software Product ServicesSoftware Product Services
Response - Upgrade on-site response from next business day to same day 4-hour response or 6
Hour Call To Repair
Coverage - Extend hours of coverage from next business day to 9 hours x 5 days to 24 hours x 7
days
Duration Select duration of coverage for a period of 1, 3, 4 or 5 years
Product support provides the customer access to HP's experienced technical support resources, as well as access to HP's Information Services database for support on a variety of multi­vendor/multiplatform software products. Product support includes escalation and problem coordination with the appropriate engineering group. HP Services offer a variety of options to allow you to tailor your product service to meet the needs of your organization. Basic warranty on products can be uplifted from day one to ensure you receive the service you need when you need it.
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 16
QuickSpecs

Configuration Information

1.
Power Switch
2.
Fibre Channel Ports
3.
CLI Port
4.
Ethernet Port
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Dual Controller MSA2300fc
Dual Controller MSA2300fc
Dual Controller MSA2300fcDual Controller MSA2300fc
5.
Service Port
6.
Expansion Port
Rear Panel components
Rear Panel components
Rear Panel componentsRear Panel components
1.
Power Supply 1
2.
System fan 1
3.
Dual 7 segment display board (for future use)
Rear Panel components
Rear Panel components
Rear Panel componentsRear Panel components
1.
Service Port
2.
Unit Locator
3.
Power Switch
MSA70 Dual I/O 2.5-inch 25 Drive Enclosure
MSA70 Dual I/O 2.5-inch 25 Drive Enclosure
MSA70 Dual I/O 2.5-inch 25 Drive EnclosureMSA70 Dual I/O 2.5-inch 25 Drive Enclosure
4.
SAS in connector
5.
SAS out connector
6.
I/O module bay
MSA2000 Dual I/O 3.5-inch 12 Drive Enclosure
MSA2000 Dual I/O 3.5-inch 12 Drive Enclosure
MSA2000 Dual I/O 3.5-inch 12 Drive EnclosureMSA2000 Dual I/O 3.5-inch 12 Drive Enclosure
4.
DC Voltage / Fan Fault
5.
AC Power Good
7.
8.
9.
6.
7.
I/O module bay System fan 2 Power supply 2
SAS In Port SAS Out Port
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 17
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Configuration Information
Configure to Order Program Information
Configure to Order Program Information
Configure to Order Program InformationConfigure to Order Program Information
HP introduces the new Configure to Order program for the MSA2000 family The MSA2000 models and options may or may not be factory installed in a rack with add-on controllers, switches, hubs, MSA2000 disk enclosures and hard drives. The MSA2000 arrays may be integrated with ProLiant servers or as standalone storage. Orders to be shipped through the CTO process must have a minimum of two drives ordered per controller. SAN Starter Kits are not eligible for CTO.
Description
Description
DescriptionDescription HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) HP StorageWorks 2300fc G2 Modular Smart Array Controller HP StorageWorks 2312fc G2 Dual Controller Modular Smart Array (LFF) HP StorageWorks 2324fc G2 Dual Controller Modular Smart Array (SFF) HP 2000fc Modular Smart Array Controller (ONLY for use by those wishing to build an older model MSA2012fc)) HP MSA2000 3.5in Single I/O 12 Drive Encl HP MSA2000 3.5in Dual I/O 12 Drive Encl HP MSA2000 Drive Enclosure I/O Module HP MSA2 146GB 3G 15K 3.5-inch SAS HDD HP MSA2 300GB 3G 15K 3.5 inch SAS HDD HP MSA2 450GB 3G 15K 3.5 inch SAS HDD HP MSA2 500GB 7.2K 3.5 inch SATA HDD HP MSA2 750GB 7.2K 3.5 inch SATA HDD HP MSA2 1TB 7.2K 3.5 inch SATA HDD
Product #
Product #
Product #Product # AJ948A#0D1 AJ949A#0D1 AJ798A#0D1 AJ795A#0D1 AJ797A#0D1 AJ744A#0D1 AJ749A#0D1 AJ750A#0D1 AJ751A#0D1 AJ735A#0D1 AJ736A#0D1 AJ737A#0D1 AJ738A#0D1 AJ739A#0D1 AJ740A#0D1
MSA70
MSA70
MSA70MSA70 Single I/O, single domain
Single I/O, single domain
Single I/O, single domainSingle I/O, single domain 25 Small Form Factor
25 Small Form Factor
25 Small Form Factor25 Small Form Factor (SFF) drive bays
(SFF) drive bays
(SFF) drive bays(SFF) drive bays MSA70 I/O Module
MSA70 I/O Module
MSA70 I/O ModuleMSA70 I/O Module Makes the standard
Makes the standard
Makes the standardMakes the standard MSA70 (above) into a
MSA70 (above) into a
MSA70 (above) into aMSA70 (above) into a dual I/O, dual domain
dual I/O, dual domain
dual I/O, dual domaindual I/O, dual domain JBOD
JBOD
JBODJBOD SAS Drives (SFF 2.5-inch)
SAS Drives (SFF 2.5-inch)
SAS Drives (SFF 2.5-inch)SAS Drives (SFF 2.5-inch)
SATA Drives (SFF 2.5-
SATA Drives (SFF 2.5-
SATA Drives (SFF 2.5-SATA Drives (SFF 2.5­inch)
inch)
inch)inch)
35.25 x 23.5 x 15.75 in (89.5 x 59.7 x 40.0 cm)
HP StorageWorks Dual Domain I/O Module
NOTE:
NOTE:
The I/O Module is a field upgradeable Option Kit the addition of which in the
NOTE:NOTE: MSA70 will allow dual domain capability providing higher level of redundancy and reliability
HP 72GB 3G 10K SAS 2.5-inch SFF DP HDD HP 146GB 3G 10K SAS 2.5-inch SFF DP HDD HP 36GB 3G 15K SAS 2.5-inch SFF DP HDD HP 72GB 3G 15K SAS 2.5-inch SFF DP HDD
NOTE:
NOTE:
Only Dual Port (DP) drives will work in the Dual Domain environment. Dual
NOTE:NOTE: Domain environment requires the HP StorageWorks Dual Domain I/O Module Option (# AG779A).
HP 60 GB 1.5 G SATA 5.4K 2.5-inch SFF HDD HP 120 GB 1.5G SATA 5.4K 2.5-inch SFF HDD HP 250 GB 3G 5.4K 2.5-inch SATA SFF ETY HDD
DA - 13187 EMEA — Version 2 — February 10, 2009
418800-B21
AG779A
384842-B21 418367-B21 418369-B21 418371-B21
379306-B21 458924-B21 460355-B21
Page 18
QuickSpecs
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
Configuration Information
NOTE:
NOTE:
SATA drives are not dual port (DP) drives.
NOTE:NOTE: NOTE:
NOTE:
Go to the HP Hard Drive Compatibility table for complete drive compatibility
NOTE:NOTE: information ( unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data
Step 1 - MSA2000fc G2 - Base Configuration
Step 1 - MSA2000fc G2 - Base Configuration
Step 1 - MSA2000fc G2 - Base ConfigurationStep 1 - MSA2000fc G2 - Base Configuration
Select one:
Select one:
Select one:Select one: Model Name
Model Name
Model NameModel Name HP StorageWorks 2012
Modular Smart Array 3.5­inch Drive Bay Chassis
HP StorageWorks 2024 Modular Smart Array 2.5­inch Drive Bay Chassis
There are two array-head chassis - one with twelve 3.5-inch large form factor bays, the other with twenty-four 2.5-inch small form factor drive bays. For additional twelve additional drive bays purchase an MSA2000 3.5-inch Disk Enclosure. You may attach a total of four MSA2000 Drive Enclosures for a total of sixty LFF drive bays. For 25 additional SFF drive bays purchase an MSA70 JBOD with the 2nd I/O module. You may attach a total of three MSA70 JBODs for a total of ninety-nine LFF drive bays. Single controller arrays support Single I/O Disk Enclosures; dual controller arrays support Dual I/O Disk Enclosures.
Model Description:
Model Description:
Model Description:Model Description: Controller-less chassis with twelve Large Form Factor (LFF) MSA2 drive bays. Space
for two controllers.
Controller-less chassis with twenty-four Small Form Factor (SFF) ProLiant drives bays. Space for two controllers. (SFF)
http://www.hp.com/products/harddiskdrives
). Using hard drives in
Part Number
Part Number
Part NumberPart Number
AJ948A
AJ949A
Step 2 - Options
Step 2 - Options
Step 2 - OptionsStep 2 - Options
Select each option with quantities specified.
Step 2a - Options
Step 2a - Options
Step 2a - OptionsStep 2a - Options
Description with Parts Shipped:
Description with Parts Shipped:
Description with Parts Shipped:Description with Parts Shipped: HP StorageWorks 2300fc G2 Modular Smart Array Controller
(for either the LFF MSA2012, SFF MSA2024, or the two DC-powered chassis)
Step 2b - SAS and SATA Drive Options
Step 2b - SAS and SATA Drive Options
Step 2b - SAS and SATA Drive OptionsStep 2b - SAS and SATA Drive Options
NOTE:
NOTE:
SATA drives are designed for archival or reference data. They should not be used in a heavy or intense I/O environment.
NOTE:NOTE: Those situations require the use of enterprise-class SAS drives. MSA2 3.5-inch drives are for use only with MSA2000 products.
MSA2 Large Form Factor (LFF) SAS drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure
MSA2 Large Form Factor (LFF) SAS drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure
MSA2 Large Form Factor (LFF) SAS drives for MSA2312fc and MSA2000 3.5-inch Disk EnclosureMSA2 Large Form Factor (LFF) SAS drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure HP StorageWorks MSA2 146GB 3G 15K 3.5-inch Dual-port SAS LFF HDD HP StorageWorks MSA2 300GB 3G 15K 3.5-inch Dual-port SAS LFF HDD HP StorageWorks MSA2 450GB 3G 15K 3.5-inch Dual-port SAS LFF HDD MSA2 Large Form Factor (LFF) SATA drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure
MSA2 Large Form Factor (LFF) SATA drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure
MSA2 Large Form Factor (LFF) SATA drives for MSA2312fc and MSA2000 3.5-inch Disk EnclosureMSA2 Large Form Factor (LFF) SATA drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure HP StorageWorks MSA2 500GB 7.2K 3.5-inch SATA LFF HDD HP StorageWorks MSA2 750GB 7.2K 3.5-inch SATA LFF HDD HP StorageWorks MSA2 1TB 7.2K 3.5-inch SATA LFF HDD ProLiant Small Form Factor (SFF) SAS drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SAS drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SAS drives for MSA2324fc and MSA70 JBODProLiant Small Form Factor (SFF) SAS drives for MSA2324fc and MSA70 JBOD HP 72GB 3G 10K 2.5-inch SAS SFF SP HDD (MSA70 only) HP 146GB 3G 10K 2.5-inch SAS SFF SP HDD (MSA70 only)
Quantity
Quantity
QuantityQuantity
1 or 2
Part Number
Part Number
Part NumberPart Number
AJ798A
AJ735A AJ736A AJ737A
AJ738A AJ739A AJ740A
375861-B21 431958-B21
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 19
QuickSpecs
Configuration Information
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP 36GB 3G 15K 2.5-inch SAS SFF SP HDD (MSA70 only) HP 72GB 3G 15K 2.5-inch SAS SFF SP HDD (MSA70 only) HP 72GB 3G 10K 2.5-inch SAS SFF DP HDD HP 146GB 3G 10K 2.5-inch SAS SFF DP HDD HP 36GB 3G 15K 2.5-inch SAS SFF DP HDD HP 72GB 3G 15K 2.5-inch SAS SFF DP HDD ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBODProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD HP 60 GB 1.5 G 5.4K 2.5-inch SATA SFF HDD HP 120 GB 1.5G 5.4K 2.5-inch SATA SFF HDD
Step 2c - Drive Enclosure Options
Step 2c - Drive Enclosure Options
Step 2c - Drive Enclosure OptionsStep 2c - Drive Enclosure Options
Should you want a drive enclosure, the model you choose depends on which array model it attaches to. If it is a single controller array, then choose the JBOD designated as "Single I/O". If it is attaching to a dual controller array then choose the "Dual I/O" JBOD
HP StorageWorks MSA2000 Single I/O 3.5-inch 12 Drive Enclosure (use with single controller array heads. Ships with two .6m SAS to SAS cables)
HP StorageWorks MSA2000 Drive Enclosure I/O Module (Use to upgrade the Single I/O model to dual I/O. No cable included)
HP StorageWorks MSA2000 Dual I/O 3.5-inch 12 Drive Enclosure (use with dual controller array heads. Ships with two .6m SAS to SAS cables)
HP StorageWorks 70 Modular Smart Array (MSA70) SFF 2.5-inch drive Single I/O JBOD Single I/O, single domain. 25 Small Form Factor (SFF) drive bays (use only with MSA2324fc array head. Includes one miniSAS to miniSAS cable)
HP StorageWorks Dual Domain I/O Module for MSA70 Makes the standard MSA70 (above) into a dual I/O, dual domain JBOD (Includes one miniSAS to miniSAS cable)
MSA70 NOTE:
MSA70 NOTE:
MSA70 NOTE:MSA70 NOTE: StorageWorks Dual Domain I/O Module Option (# AG779A). For more information on the MSA70, go to the MSA70 Home Page:
http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/drive_enclosures/msa70/index.html
Only Dual Port (DP) drives will work in the Dual Domain environment. Dual Domain environment requires the HP
431933-B21 431935-B21 384842-B21 418367-B21 418369-B21 418371-B21
379306-B21 458924-B21
AJ749A
AJ751A
AJ750A
418800-B21
AG779A
Step 2c - SAS Cable Options
Step 2c - SAS Cable Options
Step 2c - SAS Cable OptionsStep 2c - SAS Cable Options
miniSAS to miniSAS Cables:
miniSAS to miniSAS Cables:
miniSAS to miniSAS Cables:miniSAS to miniSAS Cables: Connecting MSA2300fc controller to MSA70 JBOD if a longer cable is desired.
HP Ext miniSAS to miniSAS 1m Cable HP Ext miniSAS to miniSAS 2m Cable SAS to miniSAS Cables:
SAS to miniSAS Cables:
SAS to miniSAS Cables:SAS to miniSAS Cables: Connecting MSA2300fc controller to MSA2000 3.5-inch Disk Enclosure
HP SAS to miniSAS .5m Cable HP SAS to miniSAS 1m Cable HP SAS to miniSAS 2m Cable SAS Cables (SAS to SAS)
SAS Cables (SAS to SAS)
SAS Cables (SAS to SAS)SAS Cables (SAS to SAS) Older MSA2000fc controller to MSA2000 3.5-inch Disk Enclosure or cascading two MSA2000 3.5-inch Disk Enclosures if included .6m cables is not of sufficient length
HP Ext SAS to SAS 1m Cable
DA - 13187 EMEA — Version 2 — February 10, 2009
407337-B21 407339-B21
419569-B21 419570-B21 419571-B21
389665-B21
Page 20
QuickSpecs
Configuration Information
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP Ext SAS to SAS 2m Cable
Step 3 - Other MSA2300fc Options
Step 3 - Other MSA2300fc Options
Step 3 - Other MSA2300fc OptionsStep 3 - Other MSA2300fc Options
Description
Description
DescriptionDescription 1st generation HP StorageWorks 2000fc Modular Smart Array Controller (older version) (ONLY for those desiring to configure an older MSA2012fc by using the MSA2012 chassis and installing either one or two of this
model controller. The resulting array head will have the attributes of the first generation MSA2012fc with no support for SFF drives, no HP-UX, limited total drive count, limited snaps, etc.)
Choose optional Power Cord for Non-U.S. Configurations
Choose optional Power Cord for Non-U.S. Configurations
Choose optional Power Cord for Non-U.S. ConfigurationsChoose optional Power Cord for Non-U.S. Configurations
NOTE:
NOTE:
Shipped standard with all units.
NOTE:NOTE:
2 ea. Power Cord, 110/220 VAC, US/Canada/Mexico 227099-001 Power Cord, 220/240 VAC, (US/Canada/Mexico) Power Cord, (Australia/China/New Zealand) Power Cord, (Central Europe) Power Cord, (United Kingdom/Hong Kong) Power Cord, (Switzerland) Power Cord, (Italy) Power Cord, (Denmark) Power Cord, (Japan) Power Cord, (South East Asia/India)
Quantity
Quantity
QuantityQuantity
1 or 2
2 2 2 2 2 2 2 2 2
389668-B21
Part Number
Part Number
Part NumberPart Number
AJ744A
227099-001 227098-001 157215-001 157216-001 157219-001 157217-001 157218-001 139867-001 157220-001
Step 4 - Choose Supported Options For Fibre Channel Infrastructure
Step 4 - Choose Supported Options For Fibre Channel Infrastructure
Step 4 - Choose Supported Options For Fibre Channel InfrastructureStep 4 - Choose Supported Options For Fibre Channel Infrastructure
Fibre Channel
Fibre Channel
Fibre ChannelFibre Channel Host Bus Adapters -
Host Bus Adapters -
Host Bus Adapters -Host Bus Adapters ­X86 servers
X86 servers
X86 serversX86 servers
Model
Model
ModelModel FC2242SR FC2142SR FC2243 FC2143 FC1242SR FC1142SR FC1243 FC1143 Bladeserver HBA Bladeserver HBA
81E
82E
81Q
Description
Description
DescriptionDescription 4Gb PCI-E Dual Channel HBA for Windows and Linux 4Gb PCI-E for Windows and Linux 4Gb PCI-X Dual Channel for Windows and Linux 4Gb PCI-X 2.0 for Windows and Linux 4Gb PCI-E Dual Channel HBA for Windows and Linux 4Gb PCI Express HBA for Windows and Linux 4Gb PCI-X 2.0 Dual Channel for Windows and Linux 4Gb PCI-X 2.0 for Windows and Linux Lpe1105-HP 4Gb FC HBA for HP c-Class BladeSystem QMH2462 4Gb FC HBA for HP c-Class BladeSystem
Windows and Linux StorageWorks 8Gb, PCIe to Fibre Channel Host Bus
Adapter for Windows, Windows Server, and Linux StorageWorks 8Gb, PCIe to Fibre Channel Host Bus
Adapter for Windows, Windows Server, and Linux StorageWorks 8Gb, PCIe to Fibre Channel Host Bus
Adapter for Windows, Windows Server, and Linux
Part Number
Part Number
Part NumberPart Number
A8003A
A8002A AD168A AD167A
AE312A AE311A AE369A
AB429A 403621-B21 403619-B21
AJ762A
AJ763A
AK344A
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 21
QuickSpecs
Configuration Information
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
82Q
Fibre Channel
Fibre Channel
Fibre ChannelFibre Channel Host Bus Adapters -
Host Bus Adapters -
Host Bus Adapters -Host Bus Adapters ­Integrity, PA-Risc servers
Integrity, PA-Risc servers
Integrity, PA-Risc serversIntegrity, PA-Risc servers
Fibre Channel Switches
Fibre Channel Switches
Fibre Channel SwitchesFibre Channel Switches
Integrity and HP9000 HP-UX v3, and v2
Integrity HP-UX v3 and v2
Integrity HP-UX v3 and v2
Integrity server blades BL860c and BL870c HP-UX v3 and v2
Integrity HP-UX v3 and v2
Integrity HP-UX v3 and v2
Integrity server blades BL860c and BL870c HP-UX v3
Integrity HP-UX v3
Integrity HP-UX v3
Integrity HP-UX v3
Integrity and HP9000 HP-UX v3 and v2
Integrity and HP9000 HP-UX v3 and v2
Integrity and HP9000 HP-UX v3 and v2
Brocade 4/12 SAN Switch for HP c-Class Blade System, Base Brocade 4/24 SAN Switch for HP c-Class Blade System, Full Fabric Brocade 4/24 SAN Switch for HP c-Class Blade System, Power Pack HP StorageWorks 4/8 Base SAN Switch HP StorageWorks 4/16 SAN Switch HP StorageWorks 4/16 SAN Switch Power Pack HP StorageWorks 4/8 SAN Switch HP StorageWorks 4/32B Base SAN Switch HP StorageWorks 4/32B Full SAN Switch HP StorageWorks 4/32B Power Pack SAN Switch HP StorageWorks 8/8 Base SAN Switch HP StorageWorks 8/8 SAN Switch
StorageWorks 8Gb, Dual Channel PCIe to Fibre Channel Host Bus Adapter for Windows, Windows Server, and Linux
HP PCI-X 2.0 1Port 4Gb
HP PCI-X 2.0 2Port 4Gb Fibre Channel HBA
HP PCIe 2Port 4Gb Fibre Channel HBA
HP BLc QLogic QMH2462 FC HBA Opt Kit
HP PCIe 1Port 4Gb Fibre Channel HBA
HP PCIe 2-Port 4Gb Fibre Channel HBA
HP BLc Emulex LPe1105 FC HBA Opt Kit
HP PCIe 1p 4Gb FC and 1p 1000BT Adapter
HP PCIe 2p 4Gb FC and 2p 1000BT Adapter
HP PCIe 2p 4Gb FC and 2p 1000BSX Adapter
PCI-X 2Gb Fibre Channel/1000Base-SX HBA
HP PCI-x 1p 4Gb FC and 1p 1000BT Adapter
HP PCI-x 2p 4Gb FC and 2p 1000BT Adapter
AJ764A
AB378B
AB379B
AD300A
403619-B21
AD299A
AD335A
403621-B21
AD221A
AD222A
AD393A
A9782A
AD193A
AD194A
AE370A
AE372A
AE371A
A7984A A7985A A7987A
A8000A AG756A AG757A AG758A AM866A AM867A
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 22
QuickSpecs
Configuration Information
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 8/24 Base SAN Switch HP StorageWorks 8/40 Base SAN Switch HP StorageWorks 8/40 Power Pack+ SAN Switch HP StorageWorks 8/80 Power Pack+ SAN Switch HP StorageWorks 8/80 Base SAN Switch HP StorageWorks 4/256 SAN Director HP StorageWorks 4/256 Power Pack SAN Director HP StorageWorks DC SAN Backbone Director Brocade 8/12c SAN Switch for HP BladeSystem c-Class Brocade 8/24c SAN Switch for HP BladeSystem c-Class Brocade 8/24c SAN Switch for HP BladeSystem c-Class Power Pack+ 8 Gb Simple SAN Connection HP StorageWorks 8/20q Fibre Channel Switch (8 switch ports active) HP StorageWorks 8Gb Simple SAN Connection Kit (8 switch ports active) HP StorageWorks 8/20q Fibre Channel Switch (16 switch ports active) Cisco MDS 9124 8-ports Active Fabric Switch Cisco MDS 9124 16-ports Active Fabric Switch Cisco MDS 9124 24-ports Active Fabric Switch Cisco MDS 9124e 12-port Fabric Switch for HP c-Class BladeSystem Cisco MDS 9124e 24-port Fabric Switch for HP c-Class BladeSystem Cisco MDS 9134 24-ports Active Fabric Switch Cisco MDS 9134 32-ports Active Fabric Switch Cisco MDS 9134 26-ports Active w/kit for 48 port solution Cisco MDS 9134 34-ports Active w/kit for 64 port solution MDS 9222i Multiservice Modular Switch w/0 SFPs Cisco MDS 9216i w/o Ethernet SFP switch Cisco MDS 9216i MDS 9506 Director with Supervisor 2 MDS 9509 Director with Supervisor 2 MDS 9513 Director with Supervisor 2 MDS 9513 Director with Fabric 2 Module
Fibre Channel Cables
Fibre Channel Cables
Fibre Channel CablesFibre Channel Cables
2 m LC-LC Multi-Mode Fibre Channel Cable 5 m LC-LC Multi-Mode Fibre Channel Cable 15 m LC-LC Multi-Mode Fibre Channel Cable 30 m LC-LC Multi-Mode Fibre Channel Cable 50 m LC-LC Multi-Mode Fibre Channel Cable 2 m LC-SC Multi-Mode Fibre Channel Cable 5 m LC-SC Multi-Mode Fibre Channel Cable 15 m LC-SC Multi-Mode Fibre Channel Cable 30 m LC-SC Multi-Mode Fibre Channel Cable 50 m LC-SC Multi-Mode Fibre Channel Cable
AM868A AM869A AM870A AM872A AM871A
A7988A
A7989A
AK857A
AJ820A AJ821A AJ822A
AQ233A
AK241A
AK242A AG646A AG647A AG648A AG641A AG642A AG874A AG875A
AJ732A AJ733A
AG851A
AE390A AE390A AE388A AE389A AE376A
AJ905A
221692-B21 221692-B22 221692-B23 221692-B26 221692-B27 221691-B21 221691-B22 221691-B23 221691-B26 221691-B27
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 23
QuickSpecs
Configuration Information
Step 5 - Choose Rack Options
Step 5 - Choose Rack Options
Step 5 - Choose Rack OptionsStep 5 - Choose Rack Options
Select each required option with quantities specified.
Rack Cabinet, Customer Assembled
Rack Cabinet, Customer Assembled
Rack Cabinet, Customer AssembledRack Cabinet, Customer Assembled 5642 - 5000 Series rack
14U rack
14U rack
14U rack14U rack HP S10614 Rack with Shock Pallet
Rack Cabinets 10622 G2
Rack Cabinets 10622 G2
Rack Cabinets 10622 G2Rack Cabinets 10622 G2 10622 G2 Universal Rack w/Shock Pallet 10622 G2 Universal Rack w/Standard Pallet
Rack Cabinets under 10636 G2
Rack Cabinets under 10636 G2
Rack Cabinets under 10636 G2Rack Cabinets under 10636 G2 10636 G2 (36U) Rack Cabinet - Pallet 10636 G2 (36U) Rack Cabinet - Shock Pallet 10636 G2 (36U) Rack Cabinet - Crated 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet
Rack Cabinets 10642 G2
Rack Cabinets 10642 G2
Rack Cabinets 10642 G2Rack Cabinets 10642 G2 10642 G2 (42U) Rack Cabinet - Pallet 10642 G2 (42U) Rack Cabinet - Shock Pallet 10642 G2 (42U) Rack Cabinet - Crated 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet Modular Cooling System G2 (MCS G2) MCS G2 10642 G2 Expansion Rack
Rack Cabinets 10842 G2
Rack Cabinets 10842 G2
Rack Cabinets 10842 G2Rack Cabinets 10842 G2 10842 G2 Universal Rack w/Shock Pallet 10842 G2 Universal Rack w/Standard Pallet
Rack Cabinets 10647 G2
Rack Cabinets 10647 G2
Rack Cabinets 10647 G2Rack Cabinets 10647 G2 10647 Rack G2 Pallet
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
358254-B21
292302-B22
AF022A AF021A
AF011A AF012A AF013A AF014A
AF001A AF002A AF003A AF004A AF025A AF026A
AF042A AF041A
AF031A
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 24
QuickSpecs

Technical Specifications

MSA2000fc G2
MSA2000fc G2
MSA2000fc G2MSA2000fc G2
Modular SAN Array
Modular SAN Array
Modular SAN ArrayModular SAN Array 2300fc G2 Controller
2300fc G2 Controller
2300fc G2 Controller2300fc G2 Controller
POWER REQUIREMENTS
POWER REQUIREMENTS
POWER REQUIREMENTSPOWER REQUIREMENTS Input Power Requirements
(typ) Max Input Power Heat Dissipation TEMPERATURE AND HUMIDITY RANGES
TEMPERATURE AND HUMIDITY RANGES
TEMPERATURE AND HUMIDITY RANGESTEMPERATURE AND HUMIDITY RANGES Operating Temperature Shipping Temperature Operating Humidity Non-Operating Humidity DECLARED ACOUSTIC NOISE LEVELS
DECLARED ACOUSTIC NOISE LEVELS
DECLARED ACOUSTIC NOISE LEVELSDECLARED ACOUSTIC NOISE LEVELS Sound Power Sound Pressure SHOCK AND VIBRATION
SHOCK AND VIBRATION
SHOCK AND VIBRATIONSHOCK AND VIBRATION Shock, Operational Shock, Non-Operational Vibration, Operational Vibration, Non-
Operational PHYSICAL
PHYSICAL
PHYSICALPHYSICAL Height Depth (excluding cables)
(back of ear to back of controller handle)
Width (body only) Chassis Weight
(no controllers)
User Interface
User Interface
User InterfaceUser Interface
RAID Support
RAID Support
RAID SupportRAID Support Cache Memory
Cache Memory
Cache MemoryCache Memory
Cache Backup
Cache Backup
Cache BackupCache Backup Upgradeable Firmware
Upgradeable Firmware
Upgradeable FirmwareUpgradeable Firmware Disk Drive and Enclosure
Disk Drive and Enclosure
Disk Drive and EnclosureDisk Drive and Enclosure Protocol Support
Protocol Support
Protocol SupportProtocol Support Expansion Port
Expansion Port
Expansion PortExpansion Port
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
110 VAC 3.6A/394W; 220VAC 1.9/385W
100-240 VAC, 50/60 Hz., 4.5-1.9A; 48-60 VDC 10.4A/8.3A 1622 BTU/hr
41°F to 104°F (5oC to 40°C)
-40°F to 158°F (-40°C to 70°C) 10% to 90% RH @ 104°F (40°C) non-condensing Up to 93% RH @ 104°F (40°C)
< 6.5 Bels < 57 dBA
5G's for 11 milliseconds, half sine 15G 11ms half sine 5-500Hz, 0.21Grms flat spectrum0.000089g2/HZ Random Vibration 5-500-5Hz, 0.5 G peak to peak, sinusoidal
3.436 in/ 8.727 cm MSA2024: 20.28 in / 51.510 cm
MSA2012: 21.8 in. / 55.372 cm
17.55 in / 44.58 cm (w/ ears 19 in / 48.26 cm) MSA2012 chassis: 44 lbs. MSA2024 chassis: 43 lbs
- Status and activity provided via management interfaces Status Indicators on front of Controller
0, 1, 3, 5, 6, 10, 50 1GB Read/Write. ECC protection with backup to Flash memory (indefinite
backup) ECC protection with back up to flash memory (indefinite backup) yes 3 Gb SAS - Serial Attached SCSI / 3 Gb SATA II
MSA2000fc SAS (SFF8470) 4x lane 3 Gb SAS MSA2300fc SAS (SFF8088) 4x lane 3 Gb SAS
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 25
QuickSpecs
Technical Specifications
Regulatory
Regulatory
RegulatoryRegulatory
© Copyright 2009 Hewlett-Packard Development Company, L.P.
Safety
Safety
SafetySafety
Electromagnetic
Electromagnetic
ElectromagneticElectromagnetic Compatibility
Compatibility
CompatibilityCompatibility
RoHS and WEEE
RoHS and WEEE
RoHS and WEEERoHS and WEEE Country Approvals
Country Approvals
Country ApprovalsCountry Approvals
UL 60950-1 (USA) CAN/CSA-C22.2 No.60950-1-03 (Canada) EN 60950-1 (European Union) IEC 60950-1 ( International ) VCCI:2008-04 Class A ICES-003 Issue 4 Class A (Canada) EN55022 : (European Union Class A); CISPR 22 (International) EN61000-3-2 : (Harmonics) EN61000-3-3 : (Flicker) EN 55024 (European Union, Immunity);CISPR 24 (International Immunity) CNS 13438 Taiwan KN22 Class A (Emissions); KN24 (Immunity) RoHS-5 Compliance, China RoHS, WEEE Australia/New Zealand, Canada, China (PRC), European Union, Germany
(GS Mark), Japan, South Korea, Taiwan, United States
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart ArrayHP StorageWorks 2000fc G2 Modular Smart Array
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA - 13187 EMEA — Version 2 — February 10, 2009
Page 26
Loading...