The Hozelock Cyprio Cascade 450 pump is designed for submersible u
se only. The pump does not use oil
or grease for lubrication and can be used safely in ponds containing fish or plants. T
ater.
IMPORTANT
1. WARNING: ALWAYS UNPLUG OR DISCONNECT ALL APPLIANCES IN THE POND FROM THE ELECTRICITY SUPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED, REPAIRED, MAINTAINED OR HANDLED.
2. Do not use the supply cable to lift the pump, as this may cause damage. We recommend fitting a lifting cord when the pump is installed in deep water.
3. Do not operate or leave the pump in freezing conditions.
4. Do not allow the pump to run dry.
5. Check that the voltage marked on the pump corresponds to the mains supply.
6. A 10MA OR 30 MA RESIDUAL CURRENT DEVICE MUST
BE FITTED TO THE MAINS
SUPPLY.
7. DO NOT OPERATE THIS PUMP WITHOUT THE STRAINER CAGE ATTACHED. USING THE PUMP WITHOUT A STRAINER MAY INVALIDATE YOUR WARRANTY.
From 1st January 2005 installing this product in the garden is classed as 'notifiable' in the revised Building Regulations for England and Wales. The Regulations now require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved.
Safety Information
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
(Australia & NZ only) This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the
appliance safely. Young children should be supervised
to ensure that they do not play with the appliance.
WARNING: SAFETY AND ELECTRICAL CONNECTIONS.
1
. The pump is supplied with 10m of 3 core
electric cable which is permanently connected and sealed to the motor. The supply cable cannot be replaced. If the cable is damaged, the pump should be discarded. This product is designed to be permanently wired to the mains supply in a dry weatherproof enclosure through a Double-Pole Switched Fused Spur ­(Disconnector) to BS 3676, with a minimum contact separation of 3mm in each Pole - Fitted with a 3 or 5 Amp fuse. The installation must conform to the national and local wiring regulations which could include the use of plastic or metal conduit to protect the cable.
2. A 10MA OR 30MA RESIDUAL CURRENT DEVICE (RCD) MUST
BE FITTED TO THE
MAINS SUPPLY.
3. WARNING: THIS APPLIANCE MUST
BE EARTHED AND IT IS ESSENTIAL THAT THE CONNECTIONS ARE MADE USING THE FOLLOWING CODE;
Brown - Live
Blue - Neutral
Green/Yellow ­Earth
The BROWN lead should be connected to the LIVE terminal which may be marked with an ‘L’ or coloured brown or red. The BLUE lead should be connected to the NEUTRAL terminal which may be marked with an ‘N’ or coloured blue or black. The GREEN/YELLOW lead should be connected to the EARTH terminal which may be marked with an ‘E’ or coloured green or green/yellow.
4. If an extension cable is required, this should be connected to the end of the pump cable using a weatherproof cable connector. The joint must be positioned in a suitable weatherproof housing. The extension cable should be of 3 core
0.75mm
2
Polychloroprene rubber insulated cable (ref: HO5 RN-F) and permanently wired to the mains supply with a 3 or 5 Amp fuse.
5. The pump cable (and extension cable) should be positioned and adequately protected against damage especially where contact with gardening equipment (lawn mowers, forks etc..) children and domestic animals may occur.
6. CONSULT A QUALIFIED ELECTRICIAN OR
LOCAL AUTHORITY IF IN ANY DOUBT ABOUT WIRING TO THE MAINS SUPPLY.
ACCESSORY ASSEMBLY.
Telescopic Stem Assembly.
Take the outer telescopic stem ‘A’ and slide t
he inner stem ‘B’ into it, as shown. See Fig 1.
PUMP INSTALLATION.
Position
Position the pump in the pond or water feature ensuring that it is fully submerged in water at all times whilst the pump is running. The connection to the outlet of the pump can be made with 12.5mm (1/2”) bore hose.
Flow Control
The flow from the pump can be regulated to meet your needs by rotating the flow controller on the front of the pump. See Fig 3 (D).
Base Fixing.
Slide off the rear cover/base. Fix the base using the holes provided. Slide the motor onto the rear cover/base. For extra stability when using the fountain attachments, clip the pump onto the separate base plate. See Fig 3 (E). This can be secured to a surface with screws through the holes in each of the base plate corners.
Fountain Only.
1. Place the pump next to the pond and route the cable back to the mains supply.
2. Select the desired fountain accessory. The 2 and 3 tier fountainheads simply snap onto the fountain stem (See Fig 4). The fountain stem pushes onto the narrower tube section of the telescopic fountain stem (See Fig 4). Then place the pump in the desired position. Note: Check that the inner stem of the telescopic tube has not been pushed inside the outer tube.
3. a). 3 tier fountain – Creates a wide and attractive fountain spray. b). 2 tier fountain – Creates a higher and narrower display.
4. The ball joint - See Fig 5 (F), fits onto the pump outlet and the telescopic stem pushes onto the top. This can then be used to adjust the fountain angle so that it is vertical.
NOTE: This pump will not operate a fountain and waterfall at the same time.
Waterfall Only.
1. Fit a suitable length of hose 12.5mm bore hose on to the hose adaptor. See Fig 2 (C).
2. Route the hose back to the waterfall.
MAINTENANCE.
The Hozelock Cyprio range of Cascade pumps has been designed to allow fast and easy maintenance. As with all pumps of its kind, occasionally it will become necessary to clean
Cascade 450
INSTALLATION AND OPERATING INSTRUCTIONS.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
GB
3303
the Strainer Cage and Fountain Spray head ring.
A
lways unplug or disconnect ALL
a
ppliances in the pond from the electricity supply before putting your hands in the water or starting m
aintenance.
Fountain Head
1
. Place a coin or similar in the slot and
gently lever off the fountain head.
2. Rinse in clean water and reassemble.
Strainer.
1
. Remove the strainer from the front of the
pump by gently pulling it.
2. Rinse the strainer with clean water and
t
hen re-fit it.
Rotor Assembly.
1
. Remove the Strainer Cage as described
above.
2. Release the Chamber Front Plate, by
u
nsnapping it from the Motor Body. See
Fig 5 (G).
3. Gently pull the Chamber Front Plate
s
quarely away from the Motor Body.
4. Pull the Rotor Assembly out of the Motor
Body. See Fig 5 (H).
5
. Wash out all of the components in clean
water. Do not use detergents or other
chemical cleaners.
6
. Replace the Rotor Assembly into the
Motor Body and refit the Pump Chamber and Strainer Cage.
ALL YEAR PUMP CARE.
A quick daily check should be carried out to ensure that the pump is performing satisfactorily. Once a week- Remove and clean the Strainer Cage and Fountain Head in accordance with
the general maintenance notes. Depending on water conditions, cleaning may be r
equired more frequently. Once a year- Completely disassemble the pump including the Rotor Assembly as d
escribed in the general maintenance notes and wash all components in clean, fresh water. Replace worn or broken parts.
HOZELOCK CYPRIO 3 YEAR GUARANTEE.
If this pump, excluding the Rotor Assembly, becomes unserviceable within 1 year of the d
ate of purchase it will be repaired or replaced at our option free of charge, unless in our opinion it has been damaged or m
isused. Liability is not accepted for damage due to accident, improper installation or use. L
iability is limited to replacement of a faulty pump. This guarantee is not transferable. It does not affect your statutory rights. T
o obtain the benefits of the guarantee, firstly contact Hozelock Cyprio Consumer Services who may request that the pump is s
ent along with proof of purchase directly to
the address below.
D
AMAGE CAUSED BY RUNNING THE PUMP DRY OR BY FROST INVALIDATES THE GUARANTEE.
Hozelock Cyprio
Midpoint Park, Birmingham B76 1AB Tel: +44 (0)121 313 1122 www.hozelock.com
The Aquatics Division of Hozelock Group
33435-002
FAULT FINDING
W
ARNING: ALWAYS UNPLUG OR DISCONNECT ALL APPLIANCES IN THE POND FROM THE ELECTRICITY SUPPLY B
EFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED, REPAIRED, MAINTAINED OR H
ANDLED.
IMPORTANT - PLEASE KEEP THIS SECTION FOR REFERENCE
LOW FLOW FROM PUMP
1. Ensure the Strainer Cage is clean.
2. A small diameter outlet pipe will
restrict outlet flow.
3. Clear any blockages and adjust the flow
c
ontrols.
N
O FLOW FROM PUMP
1
. Check power supply is on. 2
. Check fuse and wiring. 3
. Check the Rotor Assembly is not
jammed, damaged or showing signs of excessive wear.
4
. Ensure the Strainer Cage is clean.
POOR FOUNTAIN DISPLAY.
1
. Clean the Fountain Head. (see
maintenance).
Fig. 4
Fig. 1
Fig. 3
Fig. 5
Fig. 2
A
B
C
F
D
E
G
H
PLEASE NOTE: Do not dispose of in household waste