Hozelock Bioforce 3000, Bioforce 4500 Instruction Manual

1350 1351
Bioforce
3000/4500
?
www.hozelock.com
2
guarantee
Hozelock Ltd.
Midpoint Park, Birmingham,
B76 1AB. England
Tel: +44 (0) 121 313 1122
www.hozelock.com
33850-000
Downloaded from www.watergardeningdirect.com
Assembly
1
2
5
3
6
4
7
Downloaded from www.watergardeningdirect.com
GB
Thank you for choosing a Hozelock quality product, you can be assured of many years of reliable service from this product.
Attention: UV Caution
Exposure to Ultra Violet (UV) radiation can be dangerous and cause damage to eyes and skin. Under no circumstances should any attempt be made to gain access to the lamp when the unit is switched on.
From 1st January 2005 installing this product in the garden is classed as ‘notifiable’ in the revised Building Regulations for England and Wales. The Regulations now require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved.
Safety Information
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
(Australia & NZ only)
This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
PLEASE READ CAREFULLY AND KEEP THESE INSTRUCTIONS
Hozelock Cyprio Bioforce filters are a new concept in fish life­support systems for garden ponds. They are:
•SMALLyetEFFICIENT
•EASYtoCONCEAL
•TROUBLE-FREEtoMAINTAIN
And they can be sited almost anywhere (See Fig 1).
When used with the appropriate pond pump, the Bioforce will remove unwanted solids from the water and convert dissolved organic and chemical fish waste into harmless compounds. In addition, the combined filter/UVC units will give Guaranteed Clear Water if the advice given in the Filter Equipment Selection Chart and in these instructions is adhered to.
Safety and Electrical Connections
WARNING: Always unplug or disconnect all appliances in
the pond from the electricity supply before putting your hands in the water whilst equipment is being installed, repaired, maintained or handled.
This product is NOT SUBMERSIBLE, and should be sited
where it cannot fall into the water or become waterlogged. However, the design is weatherproof, and Bioforce filters can safely be installed outdoors.
Direct exposure to ultra-violet light can damage eyes and
skin. DO NOT attempt to view the lamp when lit, except briefly through the viewing lens.
This product is supplied complete with 5m of 3 core
electric cable. For connection to the mains supply, use only three-core cable Ref: HO5 RN-F. This has a minimum copper cross-section of 0.75mm2 with Polychloroprene Rubber Insulation. The termination to the mains supply should be permanent, inside a dry weatherproof enclosure, through a double pole switched fused spur with a minimum contact gap of 3mm - (disconnector) to BS 3676 - and fitted with a 3 or 5 amp fuse.
Exposed cable runs should be sensibly positioned, and
protected if necessary by armoured conduit, especially if contact is likely with gardening equipment such as forks and lawnmowers, or children or domestic animals.
A 10mA or 30mA Residual Current Circuit Breaker (RCD)
MUST be fitted to the mains supply.
The supply cable cannot be replaced. If the cable is
damaged, the unit should be discarded.
The installation must conform to the national and local
wiring regulations which could include the use of plastic or metal conduit to protect the cable.
If in any doubt about wiring to the mains supply, consult a
qualified electrician or your local electricity authority.
Protect from frost if the unit is not to run year-round. In
cold winter weather (when fish are not active and algal growth ceases), the unit may be switched off. It should then be drained of water, removed (if possible) from its installation and stored in a dry, frost-protected area.
Choosing the right size
The Technical information section gives general guidelines on the specifications of pump, filter and flexible hose diameter for garden ponds up to 4500 ltrs (990 gallons). For best results, the following condition factors must also be taken into account.
Depth
Hozelock Cyprio recommend a minimum depth of 1.2m (4’) for Koi ponds.
For a pond with an average depth of less than 0.75m (2’ 6”) the Condition Factor is + 25%. Shallow ponds are subject to full penetration of sunlight, and warm up quickly. This encourages algae growth.
Location
Pond location determines the daily amount of sunlight or shade a pond receives. Ponds exposed to full sunshine throughout the day have a Condition Factor of +25%.
Climate
Climate affects water temperatures and fish activity rate/ feeding requirements. The more active the fish, the greater the demands on the filtration system.
In hot climates (eg South Africa), the Condition Factor is +35%
In temperate climates (eg Southern Europe), the Condition Factor is +15%
In a Northern European climate (eg most areas of Great Britain), the Condition Factor is +0%.
Downloaded from www.watergardeningdirect.com
Loading...
+ 5 hidden pages