Hozelock Ltd.
Midpoint Park, Birmingham,
B76 1AB. England
Tel: +44 (0) 121 313 1122
www.hozelock.com
33904-000
?
www.hozelock.com
1
E
J
D
B
K
C
I
H
A
G
F
2
M
L
3A
O
P
Q
3B5
N
6
4
7
U
T
S
U
8
R
U
U
V
W
X
9
10
Z
i
ii
iii
Y
AA
AA
CC
DD
10A10B
BB
BB
EE
EE
GB
Thank you for choosing a Hozelock quality product,
you can be assured of many years of reliable service
from this product.
INSTALLATION &
OPERATING INSTRUCTIONS
READ THESE INSTRUCTIONS CAREFULLY
BE FOR E ATTEM PTIN G IN STALL ATION.
FAILURE TO OBSERVE THE FOLLOWING
NOTICES MAY RESULT IN INJURY, PRODUCT
DAMAGE OR LOSS OF FISH.
KEEP THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
The Hozelock Cyprio EasyClear™ Fountain and
Waterfall pump is designed for submersible use in
outdoor ponds. It is an integrated unit that provides
Mechanical & Biological Filtration with an Ultra Violet
Clarifier and a Fountain and Waterfall.
Attention: UV Caution
This appliance contains a UV-C emitter. Unintended
use of the appliance or damage to the housing may
result in the escape of dangerous UV-C radiation.
UV-C radiation may, even in little doses, cause harm to
the eyes and skin. The lamp is fitted with an interlock
that will turn the lamp off when the bayonet is
removed (fig 8-X).
When switched on, the lamp can be checked for
operation in dark conditions, by looking for a bluish
glow from the Fountain outlet (Fig 1-A). Do not run the
produc t dry.
Warning: Do not attempt to operate the UV-C
emitter when it is removed from the appliance
housing.
Warning: The appliance must be disconnected from
the supply before replacing the UV-C emitter.
Important
This appliance must only be used by or under the
supervision of a responsible adult who is capable
of using the appliance in a safe way and who
understands the hazards involved. Use and store this
appliance out of reach of children and persons with
reduced physical, sensory, or mental capabilities.
Warning:
Safety & Electrical Connections
1.1 WARNING: ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICIT Y SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, CARRYING OUT ANY
MAINTENANCE OR BEING HANDLED IN ANY
WAY.
1.2 This filter has been designed for the use with
garden ponds only. Do not use this filter for any
other use (i.e. do not use this filter in swimming
pools, etc). Using the product for any other
application may result in injury or product
damage. This pump must not be used when
people are in the water.
1.3 Appliances that are obviously damaged must
not be operated.
1.4 The clear tube inside the unit is made from
quartz glass and care should be taken during
installation and maintenance. We recommend
the use of eye protection and suitable gloves.
1.5 Do not remove and operate the pump unit from
its outer housing. Using the unit without its
outer housing may invalidate your warranty.
1.6 Important:
This product is supplied with 10m of 3-core
electric cable . It is designed to be permanently
wired to the mains supply. For connection to the
mains supply use only 3-core cable (ref HO5 RNF). This has a minimum copper cross-section of
0.75mm2 with Polycloroprene-Rubber insulation.
The termination to the mains supply should be:
a) Permanent.
b) Inside a dry weatherproof enclosure.
c) Through a double pole switched fused spur to
BS 3676.
d) Fitted with a 3 or 5 amp fuse.
1.7 If an extension cable is required, this should be
connected to the end of the unit cable using
a weatherproof connector. The joint must be
positioned in a suitable weatherproof housing.
The extension cable should be of 3 core
0.75mm2 Polychloroprene rubber insulated cable
(ref: HO5 RN-F) and permanently wired to the
mains supply as described above in 1.6.
1.8 WARNING: This appliance MUST be earthed
and it is essential that the connections are made
using the following code:
•BROWN-live
•BLUE-neutral
•GREEN/YELLOW-earth.
1.9 Exposed cable runs should be sensibly positioned
and protected by armoured conduit, especially
if there is a risk of contact with gardening
equipment such as forks and lawnmowers, or
children and domestic animals.
1.10 Do not operate this product if the mains supply
cable has become damaged in any way. The
supply cable is permanently connected and
sealed to the pump and cannot be replaced.
If the cable is damaged, the unit should be
disposed of according to local regulations.
1.11 A 30mA maximum Residual Current Device
(RCD) MUST be fitted to the mains supply.
1.12 Permanent installations to the mains supply
(hard wiring), must conform to the national and
local wiring regulations. If in any doubt about
wiring to the mains supply, consult a qualified
electrician or local electricity authority.
1.13 Do not use the supply cable to lift the unit, as
this may cause damage. We recommend fitting
a lifting cord to the hook feature on the base,
when the filter is installed in deep water. (Fig
1-F). If the product needs to be moved, the
product should be switched off and lifted out of
the water using this cord.
1.14 Do not switch the pump on out of water! The
water level should be above the UVC indicator at
the ball joint (Fig 4-L).
1.15 Do not operate or leave the unit in freezing
conditions. (See the section, “Winter Storage”).
1.16 This product is not suitable for water
temperatures above 35ºC or below 0ºC.
1.17 Only use accessories which have been designed
for use with this product. The use of any other
accessories or spares may invalidate your
guarantee.
Installing this product in the garden is classed
as ‘notifiable’ in the Regulations for England
and Wales. The Regulations require you to tell
your local authority building control department
that you intend to install this product before
To help ensure your EasyClear’s long life and to
prevent damage, it is fitted with automatic thermal
overload protection. This switches the pump or UV
lamp off if either overheats. If this occurs, switch off
the power at the mains supply to the unit. If it is the
pump that has activated the Overload Protection,
check for the cause (it is usually debris blocking the
inlet of the pump or obstructing the impeller). Remove
the obstruction and wait 15 minutes for the unit to
cool down. Then switch it on again.
If it is the UV lamp that is activating the overload
protection (pump is still running but UV lamp keeps
going out after running for a short time), please
contact Hozelock Consumer Services Helpline on +44
(0)121 313 1122.
Remember: The lamp is fitted with an interlock that
will turn the lamp off when the bayonet is removed
(fig 8-X), so you can only see if the lamp is working in
dark conditions, by looking for a bluish glow from the
Fountain outlet (Fig 1-A) with the bayonet tube locked
in position.
NOTE: YOU MUST SWITCH OFF THE MAINS
SUPPLY BEFORE THE UNIT WILL RESET.
CAUTION: To avoid a safety hazard due to inadvertent
resetting of the thermal overload protection, this
product must not be used with an external switching
device, such as a timer, or connected to a circuit that is
regularly switched on and off by the electricity supply.
Periods of Operation
Keep the filter working 24 hours a day. Ideally it
should run all year round, but at least throughout the
fish-feeding season, (i.e. until the water temperature
falls below 10°C and the fish stop feeding). In winter,
operating the unit will maintain a basic level of useful
bacteria in the Biological Filter, and will help prevent
the pond icing over. However, the unit must not be
allowed to freeze. If you switch the unit off for winter,
wash the unit thoroughly before resuming filtration in
the spring (see ‘Winter Storage’). Never feed your fish
when the unit is not in use.
Before First Use
Inappropriate handling of this product during transit
may result in damage to the quartz tube. Please
inspect the quartz tube and seal before installation.
See the section “Maintenance” for details on how to
access the quartz tube and lamp.
Installation
Position - Construct a solid and level platform on
which to place the EasyClear™. The platform should be
greater than 300 mm (12”) below the water level. For
depths between 300mm and 600mm use the fountain
stem extension segments (Fig 1-K), which simply screw
together, to allow the fountain to be above the water
level. For general installation see Fig 4. When using
the EasyClear for a waterfall the entire unit should be
submersed.
Connection - Place the unit next to the pond and
route the cable back to the mains supply. Ensure that
you allow for enough cable for positioning the product
in the desired location in the pond.
Accessory Assembly
Bell Fountain (Fig 1).
Locate the Bell Support (B) to the Bell Main Body (C)
and push fully home.
Position the Bell (D) to the Body Assembly and press
into the central location. Insert this into the Fountain
Flow Adjuster (Fig 1-H).
2 and 3 tier fountain display assembly (Fig 1-G).
The plastic discs (Fig 1-E) that create the 2 and 3
tier water displays simply snap onto the fountain
stem. Push the fountain stem into the fountain stem
extension segment and screw onto the Fountain Flow
Adjuster (Fig 1-H).
Fountain Only Operation
Please note: It is not possible to completely close off
the waterfall outlet (Fig 1-I). This is to allow water
to always bypass in to the pond even if the fountain
head becomes blocked ensuring clear water. If the
pond water is not clearing sufficiently it may be
necessary to allow more water to bypass in to the
pond by opening the waterfall outlet.
The 2 and 3 tier fountainheads simply snap onto the
fountain stem. The fountain angle can be adjusted to
be vertical using the ball joint (Fig 2-L). The tightness
of the ball joint can be adjusted (Fig 2-M) if required,
the 2- Tier Fountainhead can be used to achieve an
alternative and higher display pattern than the 3-Tier.
The fountain height can be adjusted to suit your needs
by rotating the Fountain Flow Adjuster (Fig 3B-N). Turn
the Waterfall Adjuster (Fig 3A-O) until closed to obtain
the maximum fountain height.
The Bell Fountain creates a decorative ‘water bell’. The
size of the bell can be adjusted to suit your needs by
rotating the Fountain Flow Adjuster (Fig 3B-N).
Install and position the pump as previously described
and switch on.
Fountain and Waterfall Operation
Attach a suitable length (3m maximum) of 25 mm (1”)
hose to the hose tail on the Waterfall Adjuster (Fig 3AQ) and secure with a suitable hose clip and position
the outlet end of the hose in the desired position.
Screw the Waterfall Adjuster onto the waterfall outlet
on the front of the EasyClear™ (Fig 3A-Q).
Once the pump is operating the flow of the waterfall
and the height of the fountain can be independently
adjusted using the Fountain Adjuster (Fig 3B-N) and
Waterfall Adjuster (Fig 3A-O).
Install and position the pump as previously described
and switch on.
Waterfall Only Operation
(Fig 4 for general installation guide)
Screw the blanking plug onto the fountain outlet (Fig
3A- P).
Attach a suitable length (3m maximum) of 25 mm (1”)
hose to the hose tail on the Waterfall Adjuster (Fig
3A-O) and secure with a suitable hose clip and position
the outlet end of the hose in the desired position.
Screw the Waterfall Adjuster onto the waterfall outlet
on the front of the EasyClear™ (Fig 3A-Q).
Adjust the flow using the Waterfall Adjuster, (Fig 3A-
O), to suit your needs.
Install and position the pump as previously described
and switch on.
UVC Operation
The UVC will automatically switch on once the unit
has been connected to the electricity supply if the
bayonet tube is correctly locked in place.
The UVC lamp can be checked for operation by
looking for a bluish glow from ball joint outlet (Fig
1-A). Please note that this may only become visible in
low light conditions.
See Maintenance section for Lamp replacement.
Maintenance
The Hozelock Cyprio EasyClear™ has been designed
to allow fast and easy maintenance. As with all pond
equipment, occasionally it will become necessary to
clean or replace parts.
WARNING: Disconnect this product from the
electricity supply and refer to the section “Safety
& Electrical Connections” before attempting any
maintenance.
Fountain Head (Fig 1-E)
Follow the below procedure if the fountain head is
blocked:
1 - Place a coin or similar in the slot and gently lever
off the fountain head.
2 - Rinse in clean water and reassemble.
Foam
Follow the below procedure if flow appears reduced:
1 - Release the Foam Cover by pushing the two
buttons (Fig 5-R) and lift the cover (Fig 6-S).
2 - Remove the Foam (Fig 7-T). Note:- If the unit is out
of the pond for more then 20 minutes the biological
filter action may stop working. Rinse thoroughly in
pond water (do not use tap water).
3 - The Foam Cover and Base should also be rinsed in
pond water (do not use tap water).
4 – It may also be necessary to clean out the biomedia
and stones (Fig 7-U) if these have become clogged.
If this is necessary, the biomedia and stones should
be rinsed in pond water only.
5 - Reassemble the Filter.
Quartz Tube
Follow the below procedure if your pond remains
green:
1 - Remove the bayonet locking screw (Fig 8-V), twist
and lift the bayonet tube (Fig 8-W).
2 - Clean the Quartz Tube. Take extra care when
handling the Quartz tube. In hard water areas,
the quartz tube may become covered in limescale,
which will reduce efficiency. Clean the tube with a
soft cloth and a gentle de-scaler (such as vinegar
and water), rinse in water before refitting.
3 – Reassemble the bayonet tube and screw and
restart (Fig 8-X).
Warning! Ensure that the quartz tube is not
damaged before refitting.
Lamp Replacement
Follow the below procedure if the lamp needs
replacing or does not illuminate:
Change the lamp at the start of the new season. Even
though the lamp still glows it may not be giving out
any useful UV radiation. How well the EasyClear™
performs is related to the strength of the UV radiation
produced. This will slowly decline from the day your
lamp is switched on. The UVC lamp has an effective
any way or you cannot guarantee a water tight seal,
contact Hozelock Consumer Services.
Biological Filter
Normally, there is no need to remove the biomedia
as any cleaning may kill the colonies of bacteria that
make toxic waste harmless. However if the biomedia
becomes heavily clogged and does require cleaning
follow this procedure.
1 - Remove the foam.
2 - The bag of Kaldnes Biomedia (Fig 7-U) can then be
removed for cleaning.
3 - Wash in pond water.
4 - Reassemble the filter and restart.
Rotor Cleaning/Replacement
If the no water is being pumped or flow is reduced,
remove the quartz tube and lamp as described above,
then follow the below procedure.
1 - Release the Foam Cover by pushing the two
buttons (Fig 5-R) and lift the cover (Fig 6-S).
2 - Remove the foam (Fig 7-T), biomedia (Fig 7-U) and
stone bag.
3 – Turn the unit over and remove the 4 fixing screws
(Fig 10-A A) and lift the base clear.
4- Remove the 2 fixing screws (Fig 10-BB) and lift the
Pump Assembly clear.
5 - Twist the Pump Chamber anticlockwise (Fig 10-CC)
and lift clear. The rotor can now be pulled out for
cleaning or replacement ( Fig 10-DD).
Important! Take extra care so as to not drop any of
the small components.
See Fig EasyClearTM 10A for assembly of the
EasyClearTM 6000 and EasyClearTM 7500 rotors and
Fig 10B for assembly of the EasyClear 9000 rotor.
6 - Reassemble the pump and 2 off fixing screws (Fig
10- BB).
7 - Reroute the cable (Fig 10-EE).
8 - Reassemble the filter, and restart.
AllYearPumpCare
A quick daily check should be carried out to ensure
that the pump is performing satisfactorily.
Once a week- Remove the outer casing and Fountain
Head in accordance with the general maintenance
notes.
Depending on pond water conditions, cleaning may be
required more frequently.
Once a year- Completely disassemble the unit
including the Rotor Assembly as described in the
general maintenance notes, and wash all components
in clean, freshwater.
Replace worn or broken parts.
Winter Storage
When not in use, the unit should be removed,
thoroughly washed and cleaned, dried and stored in
a dry frost protected area. Always store the unit with
the foam and foam cover off to ensure adequate
ventilation and drying.
Contact/SpareParts
For product advice and spares please contact
Hozelock Cyprio Consumer Services on 0121 313 1122
or visit www.hozelock.com
Fish Stocking and Density
Under normal conditions, the EasyClear™ will support
up to 1.44m (EasyClear™ 6000 & EasyClear™ 7500) or
2.16m (EasyClear™ 9000) of fish. Introduce fish slowly
over the first few weeks, up to 20% of the maximum
recommended level, increasing to 50% after six
months. The balance will allow for fish growth.
Hozelock Cyprio Clearwater Guarantee
WE GUARANTEE YOU CLEAR WATER OR YOUR
MONEY BACK.
NOTE: IN SOME CASES IT CAN TAKE UP TO 6-8
WEEKS FOR YOUR WATER TO BECOME CLEAR.
This guarantee runs for 12 months after purchase,
provided that
A refund can only be authorised by Hozelock Cyprio
and is made only at the place of purchase to the
value of the purchase price of the EasyClear™ only.
A Proof of Purchase will be required.Please note that
the Clearwater Guarantee does not cover loss of water
clarity when blanketweed, as opposed to greenwater
algae, is the cause.
3YearProductGuarantee
If this unit, excluding the Rotor Assembly, Filter Foam
& UV Lamp becomes unserviceable within 3 years of
the date of purchase it will be repaired or replaced at
our option free of charge, unless in our opinion it has
been damaged or misused. Liability is not accepted for
damage due to accident, improper installation or use.
Liability is limited to replacement of a faulty unit. This
guarantee is not transferable. It does not affect your
statutory rights.
To obtain the benefits of the guarantee, firstly contact
Hozelock Cyprio Consumer Services who may request
that the filter is sent along with proof of purchase
directly to the address provided.
DAMAGE CAUSED BY RUNNING THE EasyClear™
OUT OF WATER OR BY FROST INVALIDATES THE
GUARANTEE.
Fault Finding
Please read the safety sections of these instructions
before carrying out any remedial action on the
EasyClearTM! It may also be necessary to refer to the
maintenance section of these instructions.
LOW FLOW FROM PUMP
a - The foams may be blocked and require cleaning
b - Ensure the outer cage is clean.
c - Clear any blockages and adjust the flow controls.
d - Check white flap inside pump chamber moves
freely.
e - Ensure rotor is clean and moves freely.
POOR FOUNTAIN DISPLAY
a - As above
b - Clean the Fountain Head.
UV LAMP NOT WORKING
a - Check power supply is on.
b - Check fuse, RCD and wiring.
c - Replace the lamp.
d - The Overload Protection may have operated – see
Overload Protection section.
PUMP NOT WORKING
a - Check power supply is on.
b - Check fuse, RCD and wiring.
c- Check the rotor is not blocked.
d - The Overload Protection may have operated – see
Overload Protection section.
e - Ensure the outer cage is clean.
f – Check for water ingress in lamp area.
Technical Information
Part Number176417661768
Model600075009000
Volt s230V 50Hz230V 50Hz230V 50Hz
UVC Power ( W)91113
Total Power (W )404355
Maximum Pond size without Fish6000 ltr (1319 gal)7500 ltr (1648 gal)9000ltr (1978 gal)
Maximum Pond size with Fish4000 ltr (879 gal)5000 ltr (1099 gal)6000 ltr (1319 gal)
Hozelock Ltd.
Midpoint Park, Birmingham,
B76 1AB. England
Tel: +44 (0) 121 313 1122
www.hozelock.com
33904-000
Do not dis pose of electrical ap plianc es as unsorte d municipal was te,
use sep arate col lection facilities . Contact your local government for
information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and g et into the food chain, dam aging
your health and well-being. In the EU, when replacing old appliances
with new o nes, the retai ler is legally ob ligated to take ba ck your old
appliance for disposal at least free of charge.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.