5407366 Issue 3 April 2011 C00196081
2 of 17
Service Manual UK
Indesit
Company
English
HEALTH AND SAFETY
For the servicing of refrigeration products, containing Isobutane R600a refrigerant. These instructions are in addition to any other Company procedures already published.
Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY.
1. Only engineers who have been trained on the safe handling of Isobutane R600a refrigerant are authorised to transport, store or carry out system repairs.
2. This manual is not intended as a comprehensive repair/maintenance guide to the appliance.
3. Must only be used by suitably qualified persons having technical competence, applicable product knowledge, suitable tools and test equipment.
4. Servicing of electrical appliances must be undertaken with the appliance disconnected (unplugged from the electrical supply).
5. Servicing must be preceded by earth continuity and insulation checks, plus refrigerant leak detection.
6. Personal safety precautions must be taken to protect against accidents caused by sharp edges on metal and plastic parts.
7. After servicing, the appliance must be rechecked for electrical safety.
8. Smoking, naked flames, or operating gas and/or electrical equipment (including cordless power tools) are forbidden within the storage area, working area and vehicles used to transport Isobutane.
9. The carrying case for the scales and refrigerant must display a red flammability label Part Number C00247960 (8100063) that should be visible and readable at all times.
10. The vehicle and storage area must be ventilated as far as is reasonably practicable and the aluminium case kept out of direct sunlight. The storage temperature of Isobutane should not exceed 50°C.
11. The vehicle transporting Isobutane (R600a) refrigerant must display a Red Flammable Gas warning sticker (Part Number C00247960 [8100063]).
12. Engineers should not wear clothes that are liable to cause static discharge ('electrostatic sparking').
13. Avoid working in small rooms.
14. Do not work in cellars.
15. Whenever possible move the appliance into a larger open area away from possible ignition sources.
16. Request the customer to turn off all other electrical and gas appliances in the near vicinity of the repair and note that it is done. Customers should be advised to restrict activity within the near vicinity for a short time.
17. Isobutane refrigerant must be vented to atmosphere, (outside of the premises e.g. via open window through the clear plastic hose supplied).
18. Isobutane is heavier than air and must not be vented within 3 metres of the following: sewer cover, cellar, drain or any similar construction lower than ground level, boiler air inlet/outlet, or near any possible source of ignition.
continued...
3 of 17
Indesit Company
Service Manual UK English
HEALTH AND SAFETY
19. Working with a naked flame i.e. soldering or brazing is forbidden. Unless otherwise stated, pipework connections must only be made using the Lokring coupling system.
20. Electronic leak detectors with high voltage tips must NOT be used with any Isobutane (R600a).
21. All equipment used for this activity must be checked regularly and maintained in a safe working condition; parts must be replaced as required.
Information Regarding Isobutane Canisters
1. The maximum quantity of Isobutane an engineer should hold or store at any one time is two 1kg net aluminium canisters, supplied individually as Part Number C00218421 (2602600).
2. Canisters must be stored inside the aluminium case with the weighing scales for protection from possible damage and heat. The aluminium case must NEVER be placed next to a heat source or in direct sunlight.
3. Isobutane must only be dispensed to the appliance from the 1kg net aluminium canister placed in an upright position on the weighing scales provided.
4. All used canisters must be a returned as scrap and therefore, left out for the driver to collect and return for disposal.
5. Canisters must not be punctured or the internal valve damaged.
6. Before storing the canister it must have the extraction tap valve removed and the internal valve of the canister checked for leakage using leak detector (Leak Detector: Part Number C00222861 [5700043]).
7. All used canisters and those found to be leaking should be exhausted to atmosphere to ensure they are emptied completely. Refer to the following paragraph.
8. Refit the extraction tap if necessary, open the tap and then invert the canister. This must be done outside in open air away from buildings and ignition sources and complying with Item 18 on previous page.
STABILITY BRACKET
The stability bracket MUST be fitted to the wall or floor behind every 17** fridge model. Full instructions are published in the customer instruction book.
THERMOSTAT REPLACEMENT
All replacement thermostats must have the capillary phial taped/insulated where it is routed past any electrical terminations, in the same way as the original one fitted to the appliance. Replacement thermostats will not have the insulating tape already fitted and this MUST be done before the work is completed.
4 of 17
Service Manual UK
Indesit
Company
English
CONTENTS
Health & Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 3
Index & Serial Number / Product Identity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 7
Product Description with Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Door Reversal Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 - 11
'J' Models ~ Joining Kit Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 - 13
Wiring Connection Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3 Terminal Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Theoretical Wiring Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PRODUCT IDENTITY
Mod. - - - - - -
TI
Cod.
93139180000 S/N 704211801
220 - 240 V- 50 Hz 150 W
W
Fuse
A
Max 15 w
Total
Gross Bruto Brut
Compr.
Kompr.
Syst.
R134 a
kg 0,090
Gross Bruto Brut
340
Net Util Utile
Gross Bruto Brut
Freez. Capac
Poder de Cong
75
Made in - - - - 13918
Test
P.S-I.
Pressure HIGH-235
LOW 140
kg/24 h
4,0
Class
Clase
N
Classe
1
2
Example
1 Industrial Code:
93 13918 0000
0000 original production
Commercial Code*
Factory of origin
2 Serial Number:
704 1801
Build number that day, e.g. 1801th built
Day of manufacture, e.g. 21
st
of month
Month of manufacture, e.g. April
21
Year of manufacture, e.g. 2007
*Vital for correct model information and system identification
Other numbers denote major production changes
5 of 17
Indesit Company
Service Manual UK English
MODEL INTRODUCTION
The models included in this publication are 1500 and 1700 mm high larder fridges, introduced in March 2007. All models are similar with regard to the furniture design, but there are variations for energy-banding (A and A+), exterior colour and 'V' models that have an air circulation fan in the fridge compartment.
For banding and colour information, refer to the Front Cover and/or Specifications page.
The appliance is 'wet wall' design so defrosting is automatic, with the water draining into a gutter and a dissipator. Doors are reversible but do require a T20 Torx key to remove the plinth/kick strip.
A thermostat mounted behind the control panel/top facia controls the temperature; the door switch is also mounted in the same area.
JOINING MODELS & JOINING KIT OVERVIEW
Model numbers with the suffix 'J' (= JOINING) at the end, signify that the model can be joined/linked to the freezer. Example: SD1722J joined to UP1722J.
A joining kit is available and full instructions will be included with the kit. Similar instructions are also published in this manual.
When installing and joining these models together, the larder fridge must always be on the right hand side with the matching freezer on the left hand side. The fridge is supplied with the door hinged on the right hand side whereas the freezer door will be on the left hand side, i.e. both grab handles positioned in the middle. The reason for the positioning is that the freezer has extra system pipework routed up and down, close to its right hand side panel. The affect of this, is to warm the side panel and in doing so, removing the risk of cross-ambient temperatures between the fridge and freezer, which would otherwise cause condensation.
ANTI-BACTERIA (Hygiene Control)
Some models have anti-bacteria protection (hygiene control) - built in protection for life of the product. Food safety is becoming increasingly important to consumers with more and more cases of food poisoning.
The hygiene control is built into the plastic of the fridge interior during manufacture so it cannot wash or wear out. It provides permanent protection against bacteria as it reduces on contact the spread of food poisoning bacteria, which can cause contamination and odour.
It gives extra hygiene reassurance as it kills or inhibits the growth of any bacteria, which may come into contact with the interior surfaces of the fridge.
The anti-bacteria protection is approved safe for use in food contact applications by the European Scientific Committee for Food and has proven safe over many in personal care and household cleaning products.products.
6 of 17
Service Manual UK
Indesit
Company
English
SPECIFICATIONS
GENERAL:
Manufactured in Great Britain: Appliance Type Larder Fridges Static / Frost Free Static Door Reversibility Yes Plug/Cable EU / 1.6M
Noise Level ’A’ band models ~ 42dB - ’A+’ band models 40dB
Climate Class (Rating Plate) ’A’ band models ~ SN.N.ST = 10°C to 38°C
’A+’ band models ~ SN.N.ST.T. = 10°C to 43°C
Refrigeration Type Static / Wet Wall (V models = Include a ventilation fan)
DIMENSIONS & WEIGHT:
Models: SD15** SD17** Height: 1500 mm 1750 mm Width: 600 mm 600 mm Depth: 655 mm 655 mm Weight Gross: 54.4 kg 60.1 kg Weight Net: 51.4 kg 57.3 kg
CAPACITIES / VOLUME:
Gross Volume Net Volume
Fridge: SD15** 290 litre 288 litre Fridge: SD17** 350 litre 348 litre
Colours Introduction Date - March 2007
Polar White
SD1511 SD1521 SD1711 SD1711V
SD1721
SD1721VHA SD1746
Argento Vivo SD1513 SD1723
Inox SD1522
SD1522HA SD1712V SD1722J SD1722JHA SD1722VHA
'V' = Ventilation Fan 'J' = Joining models – SD & UP1722J
'HA’ = Hotpoint / Ariston brand - Introduction April 2008.