oshizaki reserves the right to change specifications without notice.
H
Item #
Project:
URC-F
Hoshizaki
SRC-H/SRK-H
REMOTE CONDENSER SERIES
Qty:
*AutoCad available on KCL
URC-F/SRC-H/SRK-H
2/08
Item # 13084
URC-5F
Air-Cooled
URC-6F
Air-Cooled
SRK-7H
Air-Cooled
URC-7F
Air-Cooled
URC-9F
Air-Cooled
SRC-10H
Air-Cooled
URC-12F
Air-Cooled
SRK-14H
Air-Cooled
URC-14F
Air-Cooled
URC-20F
Air-Cooled
URC-21F
Air-Cooled
URC-24F
Air-Cooled
URC-6F
Remote Condenser
Remote Condenser
URC-5F
URC-6F
SRK-7H
URC-7F
URC-9F
SRC-10H
URC-12F
SRK-14H
URC-14F
URC-20F
URC-21F
URC-24F
• Remote condensers for KM Series Cubers and F Series Flakers
• Quiet operation
• Improved efficiency
• Energy savings
• Weather resistant cabinet for longer life
• May be installed outdoors up to 55 feet from icemaker using a pre-charged tubing kit
• For installations exceeding 55 feet, contact Factory Service Department
KM-461MRH Cuber
KM-650MRH Cuber
KM-501MRH Cuber
F-1001MRH-(C) Flaker
KMS-750MLH Cuber
KML-600MRH Cuber
KML-631MRH Cuber
FS-1001MLH-C Cubelet
KM-900MRH(3) Cuber
KMD-700MRH Cuber
KMD-900MRH Cuber
KM-1300SRH(3) Cuber
F-1500MRH-(C) Flaker
KMS-1400MLH Cuber
KM-1340MRH Cuber
KM-2000SRH(3) Cuber
F-2000MRH(3) Flaker
KM-1601MRH(3) Cuber
KM-1601SRH(3) Cuber
KM-2400SRH(3) Cuber
URC-24F
Remote Condenser
Use with Ice Machine
Model Number
Ice Machines Sold Separately
Warranty
Valid in United States, Canada, Puerto Rico, & U.S.Territories. Contact factory for warranty in
other countries.
When used with KM Series Cubers: When used with F Series Flakers:
Three Year - Parts & Labor on entire unit. Two Year - Parts & Labor on entire unit.
© HOSHIZAKI AMERICA, INC.
618 Hwy. 74 S., Peachtree City, GA 30269 TEL 1-800-438-6087 FAX 1-800-345-1325 www.hoshizaki.com
Five Year - Parts on: air-cooled condenser coil. Five Year - Parts on: air-cooled condenser coil.
URC-F/SRC-H/SRK-H
REMOTE CONDENSER SERIES
AIR-COOLED
• URC-5F • URC-9F • URC-14F
• URC-6F • SRC-10H • URC-20F
• SRK-7H • URC-12F • URC-21F
Hoshizaki
RE M OT E AI R - C OO L E D
Model Number
Air-Cooled
Condenser
URC-5F R404-2046-2 R404-3546-2 N/A 60 lbs.
URC-6F R404-2046-2 R404-3546-2 N/A 60 lbs.
SRK-7H R404-20810 R404-35810 R404-55810 240 lbs.
URC-7F R404-2046-2 R404-3546-2 N/A 85 lbs.
URC-9F R404-2068-2 R404-3568-2 N/A 95 lbs.
SRC-10H R404-20410 R404-35410 R404-5510 180 lbs.
URC-12F R404-2068-2 R404-3568-2 R404-5568-2 110 lbs.
SRK-14H R404-20810 R404-35810 R404-55810 273 lbs.
URC-14F R404-2068-2 R404-3568-2 R404-5568-2 110 lbs.
URC-20F R404-20610 R404-35610 R404-55610 145 lbs.
URC-21F R404-20610 R404-35610 R404-55610 165 lbs.
URC-24F R404-20610 R404-35610 R404-55610 210 lbs.
R E M O T E C O N D E N S E R I N S T A L L A T I O N O N R O O F
For best performance allow 24 inch clearance for air circulation
For best performance
the Remote Condenser
should not be more
than 33 feet above the
KM Icemaker or no
more than 10 feet below
it. Thes distances are
measured from fitting to
fitting.
Liquid Refrigerant Line
EL E C T RI C A L
UR C - 5 F / U R C- 6 F / U R C- 7 F / U R C- 9 F
UR C - 1 2F / U R C - 14 F / U R C -2 0 F / U R C- 2 1 F
• 115V/60/1 (Connection to icemaker)
EL E C T RI C A L
SR K - 7 H / S R C- 1 0 H / S R K- 1 4 H / UR C - 2 4F
• 208-230V/60/1 (Connection to icemaker)
© HOSHIZAKI AMERICA, INC.
618 Hwy. 74 S., Peachtree City, GA 30269 TEL 1-800-438-6087 FAX 1-800-345-1325 www.hoshizaki.com
Order Tubing Kits Separately
20’ length
35’ length
Air Flow
21/2 inch Diameter hole in roof for tubing.
Seal after installation to prevent leaking.
Discharge line
ICEMAKER
Liquid refrigerant line
ICE STORAGE BIN
Icemaker and Storage Bin
sold separately
hipping
5’ length
5
Electrical Conduit Access
Discharge Line
Electrical connections must
meet all local codes.
Remote Condenser
fan motor connection
S
eight
W
• URC-7F • SRK-14H • URC-24F
1411/16
21
18
3/16
321
21/2
lectrical
1
3/4
8
1
211/16
2
1/2
181/8
Liquid Ref. Line
Electrical Supply
7/8” Dia.Opening
Suction Ref. Line
23/4
181/8
OP E R AT I NG LI MI T S
UR C - 5 F / U R C- 6 F / U R C- 7 F / U R C- 9 F
UR C - 1 2F / U R C - 14 F / U R C -2 0 F / U R C- 2 1 F
• Ambient Temp Range -20 - 122˚F
• Voltage Range 104 - 127V
OP E R AT I NG LI MI T S
SR K - 7 H / S R C- 1 0 H / S R K- 1 4 H / UR C - 2 4F
• Ambient Temp Range -4 - 122˚F / -22 - 122˚F
• Voltage Range 187 - 253V
1/8
3
2
iquid
1/4 L
efrigerant line
r
2
3
3/16
3
345/16
/4
1
Liquid
refrigerant line
191/2
463/8
23/4
3
3/8 Liquid
refrigerant line
4
523/8
487/16
E
conduit
access
3/8 Discharge line
URC-5F / URC-6F
24 x 18
W x D x H
5
1
11/16
2115/16
Electrical
conduit
access
3/8 Discharge line
5/16 x 18 1/8 x 36 15/16
34
W x D x H
SRK-7H / SRK-14H
52
1511/16
26
5/8 Discharge line
48
1/8 x 32 13/16
3615/16
URC-9F
43
3/8 x 19 1/2 x 43
W x D x H
407/8
Electrical
conduit
access
URC-21F
7/16 x 18 1/8 x 40 7/8
W x D x H
23/4
181/8
3/8 Liquid
refrigerant line
19-29/32"
23/4
(506mm)
23/4
21/2
1
3/4
/8
181
4
3/16
371
28-1/4"
(717mm)
463/8
23/4
3
3/8 Liquid
refrigerant line
155/8
433/4
1
487/16
121/2
3511/16
3
(68mm)
2-11/16"
2-3/4"
(70mm)
11-3/4"
299mm)
181/8
36
Pre-Charged Tubing Kits
(Sold Separately)
Refer to SPECIFICATIONS
table to determine appropriate
Tubing Kit Number for Remote
Condenser Unit specified.
11/16
2
1/2 Discharge line
/4
281
3
/8
303
iquid
/4
1
L
refrigerant line
2
37
RC-12F / URC-14F
U
7
3
13/16 x181/8 x
W x D x H
Electrical conduit
access
6-15/32"
(64mm)
1511/16
26
5/8 Discharge line
93/4
193/4
Printed in U.S.A.
5
1
11/16
9
1
7/8
4
3
13/16
Electrical
onduit
c
ccess
a
/8
3
Discharge line
RC-7F
U
0
3
3/8 x181/8 x3413/16
W x D x H
37
Liquid Refrigeration Line Fitting
Suction Refrigeration Line Fitting
Electrical Supply Hole
(61mm)
2-13/32"
(380mm)
14-31/32"
SRC-10H
1/4 x 25 3/8 x 34 7/8
30
W x D x H
407/8
Electrical
conduit
access
URC-20F
48 7/16 x 18 1/8 x 40 7/8
W x D x H
Electrical conduit
access
5/8 Discharge line
1/4 Liquid refrigerant line
URC-24F
3/4 x 19 3/4 x 36 1/32
43
W x D x H