IMPORTANT
Only qualified service technicians should attempt to install, service or maintain this icemaker. No installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/ manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the installation, maintenance and service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department for assistance.
HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
NOTE: To expedite assistance, all correspondence/communication MUST include the following
information:
Model Number
Serial Number
Complete and detailed explanation of the problem
2
• Please review this manual. It should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service and maintain the icemaker. This manual should be made available to the technician prior to installation, maintenance or service.
• Keep this manual with the icemaker for future reference.
CONTENTS
PAGE
I. SPECIFICATIONS .................................................................................................... 4
1. NAMEPLATE RATING ........................................................................................... 4
[a] KM-280MAH (Air-cooled) ................................................................................... 4
[b] KM-280MWH (Water-cooled) ............................................................................. 5
2. DIMENSIONS/CONNECTIONS.............................................................................. 6
[a] KM-280MAH....................................................................................................... 6
[b] KM-280MWH...................................................................................................... 7
II. INSTALLATION AND OPERATING INSTRUCTIONS ............................................. 8
1. CHECKS BEFORE INSTALLATION ...................................................................... 8
2. HOW TO REMOVE PANELS.................................................................................. 9
3. LOCATION.............................................................................................................. 9
4. SET UP ................................................................................................................. 10
5. ELECTRICAL CONNECTION ............................................................................... 10
6. WATER SUPPLY AND DRAIN CONNECTIONS................................................... 11
7. FINAL CHECK LIST .............................................................................................. 13
8. START UP............................................................................................................. 14
9. PREPARING THE ICEMAKER FOR LONG STORAGE ....................................... 16
III. CLEANING AND MAINTENANCE INSTRUCTIONS ............................................. 18
1. CLEANING INSTRUCTIONS ................................................................................ 18
[a] CLEANING PROCEDURE ............................................................................... 18
[b] SANITIZING PROCEDURE ............................................................................. 21
2. MAINTENANCE .................................................................................................... 22
3
I. SPECIFICATIONS
1. NAMEPLATE RATING
[a] KM-280MAH (Air-cooled)
See the Nameplate for electrical and refrigeration specifications. This Nameplate is located on the upper right hand side of the Rear Panel. Since this Nameplate is located on the Rear Panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electri­cal and refrigeration information is also on the rating label, which can be seen easily by removing only the Front Panel of the icemaker.
We reserve the right to make changes in specifications and design without prior notice.
4
[b] KM-280MWH (Water-cooled)
See the Nameplate for electrical and refrigeration specifications. This Nameplate is located on the upper right hand side of the Rear Panel. Since this Nameplate is located on the Rear Panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electri­cal and refrigeration information is also on the rating label, which can be seen easily by removing only the Front Panel of the icemaker.
We reserve the right to make changes in specifications and design without prior notice.
5
2. DIMENSIONS/CONNECTIONS
[a] KM-280MAH
Unit: inches (mm.)
6
[b] KM-280MWH
Unit: inches (mm.)