Hoshizaki IM-51BAE User Manual

IM SERVICE TRAINING
1
Featuring the
IM-51BAE
80041 9/9/99
All IM models have similar sequence of operation. This manual is designed as a generic IM Training manual.
A standard 120 volt power cord provides the electrical connection. The unit is designed to operate on a separate 15 amp circuit.
2
The water supply connection is ½”FIP and is located at the bottom right rear of the unit. A minimum 3/8” water line is required for proper operation.
The drain connection is ¾”MIP and is located on the left rear of the unit. Since the unit will likely be enclosed, it is recommended to use flexible supply and drain connections. This will allow easy removal if service is necessary. Access to the evaporator compartment is gained by removing the front and top covers.
Open the bin door and remove the front cover screws and drain pan thumbscrews. Lower the drain pan pipe into the drain hole.
Lift upward on the front panel and push backward to remove the top cover.
This horizontal evaporator and water distribution system is unique to the IM series.
The ABS water plate sprays water up into the evaporator cells to form the square IM cube.
3
The moveable water pan assembly includes the water plate, reservoir pan, and pump motor assembly.
Tension springs connect two cam arms to the water plate assembly. An actuator motor rotates the cam arms to raise and lower the water pan during the ice making cycle.
4
The front cam arm has a switch lever that operates the actuator toggle switch located above the pan assembly.
The actuator toggle switch controls the direction of rotation for the actuator motor and energizes the pump motor during the freeze cycle.
When the switch is in the right
position, the actuator motor rotates counter clock wise to lower the water pan assembly.
When the switch is in the left
position, the actuator motor turns clock wise to raise the water pan assembly.
The IM51 uses a mechanical proximity switch bin control assembly located in the bin area.
When ice fills the bin and pushes the control arm over, the activator magnet moves to the switch and closes the contacts.
The IM bin control closes the contacts to signal the control board to shut down the unit. This is different from the standard KM control, which opens the contacts to de-energize the unit.
The louver has a flip down cover to access the control switch.
The switch has 3 positions.
ICE, OFF, & WASH.
The louver covers the compressor compartment. Remove the louver screws and lift the louver forward to access the condenser coil fan assembly and compressor.
5
For easy access during preventative maintenance or service, the inlet water valve is located in the front right hand corner of the compressor compartment.