Hoshizaki DCM-60KE, DCM-60KE-P, DCM-120KE, DCM-120KE-P Instruction Manual

Page 1
CUBELET ICE DISPENSER
INSTRUCTION MANUAL
DCM-60KE DCM-60KE-P DCM-120KE DCM-120KE-P
DCM-60KE
L1L009115 (050818)
Page 2
IMPORTANT SAFETY INFORMATION ..........................................................................................................................................1
I. INSTALLATION INSTRUCTIONS ..............................................................................................................................................3
1. CONSTRUCTION ................................................................................................................................................................3
2. ACCESSORIES ...................................................................................................................................................................3
3. UNPACKING ........................................................................................................................................................................3
4. LOCATION ...........................................................................................................................................................................4
5. INSTALLATION ....................................................................................................................................................................5
6. ELECTRICAL CONNECTIONS ............................................................................................................................................5
7. WATER SUPPLY AND DRAIN CONNECTIONS .................................................................................................................5
II. OPERATING INSTRUCTIONS ..................................................................................................................................................6
1. START UP ............................................................................................................................................................................7
2. DISPENSING ICE ................................................................................................................................................................8
3. FRONT COVER ...................................................................................................................................................................8
4. PORTION CONTROL ..........................................................................................................................................................8
5. SWITCH LOCK FUNCTION .................................................................................................................................................9
6. SHUT DOWN .......................................................................................................................................................................9
7. PREPARING THE ICE DISPENSER FOR LONG STORAGE ...........................................................................................10
III. MAINTENANCE .......................................................................................................................................................................10
1. CLEANING .........................................................................................................................................................................10
2. INSPECTION AND MAINTENANCE ..................................................................................................................................12
3. BEFORE CALLING FOR SERVICE ...................................................................................................................................13
4. DISPOSAL .........................................................................................................................................................................13
5. WARRANTY .......................................................................................................................................................................14
SPECIFICATIONS .........................................................................................................................................................................14
Page 3
ENGLISH
IMPORTANT SAFETY INFORMATION
Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit.
WARNING
CAUTION
NOTICE
HYGIENE
IMPORTANT
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Indicates a hazardous situation which, if not avoided, could result in damage to the unit.
Indicates important precautions for hygiene and food safety.
Indicates important information about the use and care of the unit.
IMPORTANT
This booklet is an integral and essential part of the product and should be kept and preserved by the user.
Please read carefully the guidelines and warnings contained herein as they are intended to provide the installer/user with essential information for the proper installation and the continued safe use and maintenance of the product.
Please preserve this booklet for any further consultation that may be necessary.
WARNING
This is a commercial ice dispenser, and should be destined only to be used for the purpose for which it has been expressly designed. Any other use should be considered improper and therefore dangerous. The manufacturer will not be held liable or responsible for any damage caused by improper, incorrect and unreasonable use.
The installation, and relocation if necessary, must be carried out by qualied personnel, in accordance with current regulations, according to the manufacturer’s instructions.
Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
1
Page 4
ENGLISH
The use of any electrical appliance involves the observance of some fundamental rules. In particular: * Instances of high humidity and moisture increase the risk of electrical short circuits and
potential electrical shocks. If in doubt, disconnect the ice dispenser.
* Do not damage the power cord or pull it in order to disconnect the ice dispenser from the
electrical supply network.
* If the supply cord and/or the plug should need to be replaced, it should only be done by a
qualied service engineer.
* Do not touch the electrical parts or operate the switches with damp hands. * This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, it can however be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge providing they have been given supervision or instruction concerning use of the appliance by a person responsible for their
safety. * Children shall not play with the appliance. * Cleaning and user maintenance shall not be made by children without supervision.
* Do not attempt to modify the ice dispenser. Only qualied personnel may disassemble or
repair the appliance.
2
Page 5
I. INSTALLATION INSTRUCTIONS
1. CONSTRUCTION
Operation Panel
Dispense Switch
(DCM-60/120KE-P only)
Dispensing Outlet
ENGLISH
Air Outlet (Ventilation Louver)
Operation Switch
Ice Making Switch
Front Cover
(DCM-60/120KE only)
* Grille faces up or down depending
on models.
DCM-60/120KE DCM-60/120KE-P
Magnet Catch
Front Cover Switch
Push Lever
Grille*
Air Inlet (bottom)Air Filter
Control Panel
Adjustable Leg
Power Cord
Drain Pan
Spout
Water Pipe
2. ACCESSORIES
CD 1 Grille 1 Inlet Hose 1 Drain Hose 1 Hose Clamp 1 Brush 1
CD Grille
Drain Hose
BrushHose ClampInlet Hose
3. UNPACKING
WARNING
Children should not be allowed in reach of the packaging elements (plastic bags and expanded polystyrene) as they are potential sources of danger.
3
Page 6
ENGLISH
CAUTION
Do not lift or manoeuvre the carton by using the shipping bands.
When moving the unit by hand, hold the unit bottom.
Do not hold the lter to lift up the unit. The condenser ns inside may cause injury.
Always wear protective gloves when carrying the unit.
When handling the carton or the unpacked unit, work in pair to prevent injury.
NOTICE
Remove shipping carton, tape(s) and packing. If packing material is left in the ice dispenser, it will not work properly.
To prevent damage, do not tilt the ice dispenser more than 45°.
1) After removing the packaging, make sure that the ice dispenser is in good condition. If in doubt, please do not use the ice
dispenser but refer to professionally qualied personnel.
2) Remove the protective plastic lm from the exterior. If the ice dispenser is exposed to the sun or to heat, remove the lm after
the ice dispenser cools.
3) Remove the package of accessories. Check the contents according to “2. ACCESSORIES”.
4. LOCATION
WARNING
This ice dispenser is not intended for outdoor use.
The ice dispenser should not be located next to ovens, grills or other high heat producing equipment.
This appliance is not suitable for installation in an area where a water jet could be used.
CAUTION
The location should provide a rm and level foundation for the ice dispenser.
NOTICE
Do not place anything on top of the ice dispenser to obstruct the ventilation louver.
IMPORTANT
Normal operating ambient temperature should be within 5°C to 40°C. Water connection is cold water only. Operation of the ice dispenser, for extended periods, outside of these normal temperature ranges may affect production capacity.
Allow the clearance specied below for proper air circulation and ease of maintenance and/or service should they be required.
Top View
Left
15cm
Rear
15cm
ICE DISPENSER
Right
15cm
Side View
Front
Top
15cm
ICE
DISPENSER
15cm
Rear
Front
In some high humidity environments, condensation may form inside the machine and drip onto the oor. Do not install where the oor can be affected by water.
4
Page 7
ENGLISH
5. INSTALLATION
CAUTION
Incorrect installation can cause harm to people, animals or other items, for which the manufacturer cannot be held responsible.
Keep the adjustable leg height within 0 to 15 mm to prevent reduction in leg strength or injury caused by a falling adjuster.
* Place the ice dispenser on a rm level surface at counter top height.
* Turn the leg adjusters to level the unit in both the left-to-right and front-to-rear directions (tilt limit: within 1 cm).
Leg
Adjuster
Longer
Shorter
6. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
To prevent possible severe electrical shock to individuals or extensive damage to the unit, the icemaker must be connected
via the exible supply cord supplied with the icemaker to an appropriate outlet socket installed in accordance with local codes
and regulations i.e. AS / NZS 3000.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit
breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.
* The main control box fuse is rated at 5A and should only be replaced by a qualied service engineer.
* The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and
regulations.
* The wires in the mains lead are coloured in accordance with the following code: Green & Yellow = Earth Blue = Neutral Brown = Live
7. WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
Connect to potable cold water supply only.
* The service of a licensed plumber may be required to ensure the installation is in accordance with the local codes and
regulations.
[Connection to the water supply]
* The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia and in
accordance with AS / NZS 3500.1 and AS / NZS 3500.2. This appliance incorporates backow protection complying with AS / NZS 3500.1. No further backow protection is required for connection to the water supply.
* To avoid performance reduction or malfunction caused by scaling, the water supply should have a hardness of not more
than 50 mg/L and a silica content of not more than 30 mg/L. Otherwise, installation of a proper water treatment device will be required.
* Water supply pressure should be minimum 0.05 MPa (0.5 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78
MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
* Attach the angle end of inlet hose to the G3/4 tting at the bottom of the ice dispenser as indicated. It is a wise precaution to
have a stop valve within easy reach.
* Be sure to use the new inlet hose-sets supplied with the appliance. Do not reuse any other inlet hose-set.
* Ensure rubber tap washers are correctly positioned. Hand tighten the inlet hose sufciently to provide a leak free joint.
5
Page 8
ENGLISH
5cm air gap
Drain
Hose Clamp
Drain Hose
Water Supply Tap
Inlet Hose
BAD
Water Supply Inlet G3/4
Inlet Hose
Drain Outlet
[Connection to the drain]
* Attach the grey exible drain hose (accessory) to the tting at the bottom of the drain pan. Use the hose clamp (accessory) to
obtain a leak free joint.
* Drain lines should not be installed directly to the sewer system. A vertical air gap of a minimum of 5 cm should be between the
end of the drain hoses from the ice dispenser and the oor drain.
* The ice dispenser drain is gravity ow, ensure drain hose has an adequate pitch or fall.
GOOD BAD
Downgrade
Upgrade
II. OPERATING INSTRUCTIONS
CAUTION
Do not put your hands into the dispensing outlet. The icemaking mechanism may suddenly move, resulting in injury.
NOTICE
All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the ice dispenser to prevent damage to the compressor.
Periods of 5 to 6 hours without dispensing ice could result in wet ice or an ice bridge forming in the storage bin. Always turn off the ice making switch, and remove ice from the storage bin within 2 hours. Soggy and sticky ice should be removed continuously as produced.
This ice dispenser is programmed to suspend ice dispensing action when the push lever/dispense switch is continuously pressed for more than 2 minutes. Also, pressing and releasing the push lever/dispense switch repeatedly for extended periods may cause the protector to stop the ice dispenser.
HYGIENE
This ice dispenser is designed to produce edible ice. To keep the ice dispenser hygienic, follow the instructions in “III. 1. CLEANING”.
6
Page 9
ENGLISH
IMPORTANT
To prevent ice and/or water from scattering or splashing:
[DCM-60/120KE]
* Use a container with more than a 7 cm opening.
* Place the container about 1 cm below the dispensing outlet
when pressing the push lever to dispense ice and/or water.
Min 7 cm
About 1 cm
Clean out the storage bin once a day, or stored ice may melt and refreeze, causing mechanical problems. For efcient use of
ice, turn off the ice making switch before shutting down the ice dispenser. Ice remains available until the storage bin becomes empty, and water is always available.
[DCM-60/120KE-P]
* Use a container with more than a 7 cm opening and more than
a 12 cm height.
* Place the container in the round centre of the grille when
pressing the dispense switch to dispense ice and/or water.
Min 7 cm
Min 12 cm
Place in round centre
Operation Panel
[1] Service Call Lamp (red) [2] Lock Lamp (white) [3] Ice Making Lamp (white) [4] Water Switch [5] Ice & Water Switch [6] Ice Switch [7] Dispense Switch
Control Panel
[1] Display PORTION: Lights up when portion control is activated
BIN FULL: Lights up when storage bin is full
DRAIN: Lights up during drain cycle Indicates error code “E” in case of error [2] Drain Switch [3] Lock Switch [4] Portion Control Switch
[1] [2] [3] [4]
[1] [2] [3]
[4]
[5] [6] [7]
[DCM-60/120KE]
[DCM-60/120KE-P]
1. START UP
1) Plug in the ice dispenser.
2) Open the water supply tap.
3) Move the operation switch, located on the right side of the ice dispenser, to the “ON” position. The display on the control panel shows the current operating status.
4) Move the ice making switch, located on the right side of the ice dispenser, to the “ON” position. The ice making lamp on the operation panel lights up, and the ice dispenser starts the automatic ice making process in 5 minutes.
5) Check the water supply and drain connections for water leaks.
7
Page 10
ENGLISH
6) After 10 minutes, push the ice switch on the operation panel.
7) Press the push lever/dispense switch, and check for proper ice dispensing action.
8) The ice dispenser stops the ice making process automatically in 1 hour or so when the storage bin is lled with ice, and
restarts when ice is used.
Note: Soggy and sticky ice may be produced depending on water conditions.
2. DISPENSING ICE
1) Select your dispensing choice by pushing ice switch, ice & water switch, or water switch on the operation panel (factory adjusted to ice & water). The selected switch lights up.
2) Position a container, and dispense a desired amount of ice and/or water.
[DCM-60/120KE] Ice and/or water keeps being dispensed while the push lever is pressed. [DCM-60/120KE-P] Ice and/or water keeps being dispensed while the dispense switch is held down, or a preset amount is dispensed when the
dispense switch is pressed once (portion control).
3. FRONT COVER
The front cover is equipped with a safety device. When the front cover is removed, the ice switch, ice & water switch, and water switch
ash and no dispensing action is available.
After accessing the control panel for adjustments, replace the front cover in its correct position.
Notch (both sides)
NOTICE
To prevent damage to the magnet provided inside, do not drop the front cover from a height.
1) To remove, hold the notches on both sides of the front cover, and pull it toward you.
2) To replace, hold both sides of the front cover, insert the hooks into the holes, and securely attach it to the magnet catch.
4. PORTION CONTROL
Pushing the portion control switch on the control panel activates the preset portion control for ice and/or water dispensing. The portion control is deactivated in the default setting.
The amount of ice dispensed in the portion control depends on water quality and storage bin level. The amount of water dispensed in the portion control depends on water pressure.
Model Default Setting Adjustable Range
DCM-60KE DCM-120KE
DCM-60KE-P DCM-120KE-P
Ice: 40g Water: Not adjustable
Ice: 40g Water: 120mL
Ice: 20 - 990g (in 10g steps) Water: Not adjustable
Ice: 20 - 990g (in 10g steps) Water: 20 - 990mL (in 10mL steps)
Front Cover
Front Cover
Front Cover
Hook
Magnet Catch
2
1
Hole (two)
[a] Activating portion control
1) Remove the front cover.
2) Press the portion control switch on the control panel. The display illuminates “PORTION”.
8
Page 11
ENGLISH
3) To deactivate the portion control, press the portion control switch again. The display goes off.
4) Replace the front cover in its correct position.
[b] Adjusting portion control
1) Remove the front cover.
2) Press and hold the portion control switch on the control panel for 3 seconds. The display shows the current portion control setting for ice dispensing.
3) Press the ashing ice (-) switch or water (+) switch on the operation panel to adjust the amount of ice. The value in the display
decreases or increases by “1” every time the switch is pressed (e.g. “06” = 60g).
[DCM-60/120KE]
4) Press the portion control switch on the control panel. The display illuminates “PORTION”.
5) Replace the front cover in its correct position.
[DCM-60/120KE-P]
4) Press the portion control switch on the control panel. The display goes off and illuminates the setting again when it is stored. Then, the display shows the current portion control setting for water dispensing.
5) Press the ashing ice (-) switch or water (+) switch on the operation panel to adjust the amount of water. The value in the
display decreases or increases by “1” every time the switch is pressed (e.g. “15” = 150mL).
6) Press the portion control switch on the control panel. The display goes off and illuminates the setting again when it is stored. Then, the display illuminates “PORTION”.
7) Replace the front cover in its correct position.
5. SWITCH LOCK FUNCTION
Pushing the lock switch on the control panel locks the ice switch, ice & water switch, and water switch operations. The switch lock function is deactivated in the default setting.
1) Remove the front cover.
2) Select your dispensing choice by pushing ice switch, ice & water switch, or water switch on the operation panel. The selected
switch ashes. Press the lock switch on the control panel. The lock lamp on the operation panel lights up.
3) To deactivate the switch lock function, press the lock switch again. The lock lamp goes off.
4) Replace the front cover in its correct position.
6. SHUT DOWN
This ice dispenser must be shut down and drained every day at the end of service hours.
1) Move the ice making switch, located on the right side of the ice dispenser, to the “OFF” position.
[DCM-60/120KE]
2) Check that the lock lamp on the operation panel is off. If it is on, press the lock switch on the control panel to deactivate the switch lock function.
3) Press the ice switch on the operation panel. The ice switch lights up.
4) Place a large container right under the dispensing outlet, and keep pressing the push lever until no more ice is dispensed.
5) Remove the front cover.
9
Page 12
ENGLISH
[DCM-60/120KE-P]
2) Press and hold the ice switch, ice & water switch, and water switch at the same time
for 3 seconds. The dispense switch ashes, and the continuous dispensing becomes
available.
Note: To deactivate the continuous dispensing, move the ice making switch to the “ON”
position or remove the front cover.
3) Place a large container right under the dispensing outlet, and press the dispense switch once. The ice dispenser keeps dispensing ice for 2 minutes.
Note: To stop dispensing ice within 2 minutes, press the dispense switch again.
4) Press the dispense switch again to check no more ice is dispensed.
5) Remove the front cover. The dispense switch stops ashing, and the continuous dispensing is deactivated.
[All models]
6) Press the drain switch on the control panel. The display illuminates “DRAIN” the drain cycle of about 30 seconds.
7) After about 30 seconds, check that the display is off.
8) Replace the front cover in its correct position.
9) Move the operation switch, located on the right side of the ice dispenser, to the “OFF” position.
10) Unplug the ice dispenser.
11) Close the water supply tap.
NOTICE
When restarting the ice dispenser, make sure that more than 3 hours have passed since the ice making switch was moved to
the “OFF” position, then follow the instructions in “1. START UP”.
7. PREPARING THE ICE DISPENSER FOR LONG STORAGE
NOTICE
This ice dispenser will not work at subfreezing temperatures. To prevent damage to the water supply line, drain the ice dispenser when air temperature is below zero.
HYGIENE
When shutting down the ice dispenser for two or more days, drain the ice dispenser to prevent contamination in the water circuit.
1) Follow the instructions in “6. SHUT DOWN”.
2) Remove the inlet hose from the water supply tap, and drain the hose.
3) Ask for draining of the ice dispenser by professional qualied personnel.
III. MAINTENANCE
1. CLEANING
WARNING
Before carrying out any cleaning or maintenance operations, unplug the ice dispenser from the electrical supply network.
This appliance must not be cleaned by use of a water jet.
10
Page 13
ENGLISH
CAUTION
When using a neutral cleaner or sodium hypochlorite, thoroughly read and understand the instructions provided to prevent potential health problems.
NOTICE
Ask a trained service person to clean and sanitise the ice dispenser water system at least twice a year and to check and clean the condenser at least once a year.
To prevent possible damage, do not clean the plastic parts with water above 40°C or in a dishwasher.
IMPORTANT
For spare parts information, contact your local Hoshizaki service agent.
[a] Exterior
Wipe the exterior at least once per week with a clean, soft cloth. Use a damp cloth containing a neutral cleaner to wipe off
grease or dirt.
[b] Front Panel, Spout, Push Lever, Ice Dispensing Outlet Cleaning/Sanitisation (Daily)
1) Remove the front cover by holding the notches on both sides and pulling it toward you. See “II. 3. FRONT COVER”.
2) Loosen the band to disconnect the water pipe (A).
3) Hold the hooks on both sides of the spout, and pull it toward you.
4) Either mix 1 litre of water with 4 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended Hoshizaki sanitiser as directed.
5) Soak a clean cloth with the solution, and wipe the front cover.
6) Soak the spout in the solution for more than 3 minutes.
Use the accessory brush to clean the water pipe (B).
Rinse thoroughly, and shake to remove surplus liquid.
Note: Using a cloth to dry may re-contaminate.
7) Soak a clean cloth with the solution, and wipe the parts around the ice dispensing outlet and the push lever.
8) Replace the spout by holding the hooks on both sides and inserting them into the holes.
9) Use the band to reconnect the water pipe (A) to the
spout.
Water Pipe (A)
Band
Hole (both sides)
Spout
1
Spout
Front Cover
Water Pipe (B)
Brush
Hook (both sides)
Spout
Push Lever
Water Pipe (A)
Band
Hook (both sides)
Ice Dispensing Outlet
2
10) Replace the front cover by holding both sides, inserting the hooks into the holes, and securely attaching it to the magnet
catch. See “II. 3. FRONT COVER”.
11) The remaining solution can be used to sanitise utensils.
Lift
Note: Do not wipe dry or rinse after sanitising, but allow to
air dry.
Grille
off
[c] Grille, Drain Pan Cleaning/Sanitisation (Daily)
DCM-60/120KE-P
Grille must be level with the top of drain pan.
1) Either mix 1 litre of water with 4 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended Hoshizaki sanitiser as directed.
2) Lift the grille off the drain pan.
Drain Pan Top
DCM-60/120KE
Grille must be lower than the top of drain pan.
11
Page 14
ENGLISH
3) Soak the grille in the solution for more than 3 minutes. Rinse thoroughly, and shake to remove surplus liquid.
Note: Using a cloth to dry may re-contaminate.
4) Use the accessory brush to clean the three drain holes in the drain pan.
5) Place the grille in its correct position and direction.
[d] Air Filter
CAUTION
To prevent injury, be careful not to touch the condenser ns when removing the air lter.
Plastic mesh air lters remove dirt or dust from the air, and keep the condenser from getting clogged. If the lters get clogged, the ice dispenser’s performance will be reduced. Remove and clean the air lter(s) at least twice per month:
1) Pull out the air lter from the bottom of the drain pan.
2) Clean the air lter by using a vacuum cleaner. When severely clogged, use warm water and a neutral cleaner to wash the air lter.
3) Rinse and dry the air lter thoroughly.
Air Filter
Handle
NOTICE
After cleaning, be sure to place the air lter back in position with the handle facing down.
2. INSPECTION AND MAINTENANCE
NOTICE
To achieve optimum ice dispenser performance, the following parts need periodic inspection and maintenance: Extruding head (upper bearing) Housing (lower bearing) Mechanical seal
[a] Inspection
These parts should be inspected after two years from installation or 10,000 hours of operation, whichever comes rst, and once
a year afterwards. Replacement of these parts is required if wear exceeds factory recommendations.
Their service life, however, depends on water quality and environment. More frequent inspection and maintenance are recommended in bad or severe water conditions.
Consult with your local Hoshizaki service agent about inspection and maintenance service.
[b] Replacement
The extruding head (upper bearing) and mechanical seal must be replaced after four years from installation or 20,000 hours of
operation, whichever comes rst, to prevent the risk of serious accidents or failures. Contact your local Hoshizaki service agent
for replacement.
When the total operating time reaches 20,000 hours, the service call lamp on the operation panel lights up and the display
on the control panel ashes “PC”. Then, after 500 hours, the unit shuts down to ensure safety and the service call lamp starts ashing. Contact your local Hoshizaki service agent for replacement as soon as the service call lamp lights up.
Once the unit shuts down after 500 hours and the service call lamp starts ashing, the operation can be resumed by turning off
the operation switch and turning it back on. But the unit shuts down again after 500 hours. To resume the operation, contact your local Hoshizaki service agent for the required replacement.
Replacement of the housing (lower bearing) may be required depending on water quality and wear condition.
12
Page 15
ENGLISH
3. BEFORE CALLING FOR SERVICE
WARNING
Do not damage the refrigerant circuit.
[a] Error Code Indication
If the error code “E” is indicated on the display, before calling for service, check the following.
Code Remedy
E0 Possibility of water leaks. Turn OFF operation switch, and turn it ON again. If error code appears again, call for
service.
E1 Low ice production. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
E2 Water supply circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for
service.
E3 Gear motor failure. Turn OFF operation switch, and turn it ON again after 10 minutes. If error code appears again, call
for service.
E4 Abnormal high side pressure. Clean air lter. Check that ice dispenser is properly installed. Turn OFF operation switch,
and turn it ON again. If error code appears again, call for service.
E5 Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
Eb Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
Ed Operation board communication error. Turn OFF operation switch, and turn it ON again. If error code appears again,
call for service.
EE Gear motor failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EF Supply voltage is too low. Check that voltage is in required range and ice dispenser is not sharing a single receptacle
with other appliances. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EL Bin control switch failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EP Model setting number error. Turn OFF operation switch, and turn it ON again. If error code appears again, call for
service.
EU Controller board failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
[b] No Error Code Indication
If the ice dispenser does not work properly or does not work at all with the ice making lamp on the operation panel ashing and
no error code is indicated on the display, before calling for service, check that:
* The power is supplied to the unit. * The water is turned on.
* The air lter is clean.
For further assistance or advice, contact your local Hoshizaki service agent.
4. DISPOSAL
Comply with local regulations regarding disposal of this appliance and its refrigerant gas.
Correct disposal of this product:
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
13
Page 16
ENGLISH
5. WARRANTY
Hoshizaki warrants to the original owner/user that all Hoshizaki branded products shall be free of defects in material and/or workmanship for the duration of the “warranty period”. The warranty shall be effective for two years from the date of installation. Hoshizaki’s liability under the terms of the warranty are limited and shall exclude routine servicing, cleaning, essential maintenance and/or repairs occasioned by misuse and installations not in accordance with Hoshizaki guidelines.
Warranty repairs should be completed by an approved Hoshizaki dealer or service agency using genuine Hoshizaki components.
To obtain full details of your warranty and approved service agency, please contact your dealer/supplier, or the nearest Hoshizaki
Service ofce:
Hoshizaki Lancer
TEL: +61 8 8268 1388 FAX: +61 8 8268 1978
info@hoshizaki.com.au http://www.hoshizaki.com.au
To register your product for warranty with Hoshizaki, visit http://www.hoshizaki.com.au/warranty-registration or scan the QR code.
SPECIFICATIONS
Model DCM-60KE DCM-60KE-P
Type Air-cooled, cubelet ice, push lever type Air-cooled, cubelet ice, dispense switch type
Power Supply 1 phase 220-240 50Hz / 220-230V 60Hz 1 phase 220-240 50Hz / 220-230V 60Hz
Electric Consumption 280/320W (ambient 32°C, water 21°C) 280/320W (ambient 32°C, water 21°C)
Ice Production per 24h 60kg (ambient 10°C, water 10°C) 60kg (ambient 10°C, water 10°C)
Dimensions 350mm(W) x 585mm(D) x 695(-710)mm(H) 350mm(W) x 585mm(D) x 695(-710)mm(H)
Refrigerant R134a, 0.21kg
(GWP: 1430, CO2: 0.300t)
Insulation Foam Blowing Agent HFC-free HFC-free
Weight Net: 47kg (Gross: 56kg) Net: 47kg (Gross: 56kg)
Ambient Temp 5 - 40°C 5 - 40°C
Water Supply Temp 5 - 35°C 5 - 35°C
Water Supply Pressure 0.05 - 0.78 MPa (0.5 - 8 bar) 0.05 - 0.78 MPa (0.5 - 8 bar)
Voltage Range Rated voltage ± 6% Rated voltage ± 6%
R134a, 0.21kg (GWP: 1430, CO2: 0.300t)
Model DCM-120KE DCM-120KE-P
Type Air-cooled, cubelet ice, push lever type Air-cooled, cubelet ice, dispense switch type
Power Supply 1 phase 220-240 50Hz / 220-230V 60Hz 1 phase 220-240 50Hz / 220-230V 60Hz
Electric Consumption 480/560W (ambient 32°C, water 21°C) 480/560W (ambient 32°C, water 21°C)
Ice Production per 24h 125kg (ambient 10°C, water 10°C) 125kg (ambient 10°C, water 10°C)
Dimensions 350mm(W) x 585mm(D) x 815(-830)mm(H) 350mm(W) x 585mm(D) x 815(-830)mm(H)
Refrigerant R134a, 0.21kg
(GWP: 1430, CO2: 0.300t)
Insulation Foam Blowing Agent HFC-free HFC-free
Weight Net: 57kg (Gross: 66kg) Net: 57kg (Gross: 66kg)
Ambient Temp 5 - 40°C 5 - 40°C
Water Supply Temp 5 - 35°C 5 - 35°C
Water Supply Pressure 0.05 - 0.78 MPa (0.5 - 8 bar) 0.05 - 0.78 MPa (0.5 - 8 bar)
Voltage Range Rated voltage ± 6% Rated voltage ± 6%
Note: The above specications are for the representative models.
This product includes a hermetically sealed refrigeration system that contains uorinated greenhouse gases.
R134a, 0.21kg (GWP: 1430, CO2: 0.300t)
14
Loading...