Horiba LAQUA F-70 Specifications

WATER QUALITY
ANALYZERS
pH
mV(ORP)
ION
Conductivity
DO
Resistivity
Salinity
TDS
http://www.horiba-water.com/
ELECTRODE LINE UP
HORIBA popular electrode is now even tougher and responds faster
Enhanced stability and minimized drift
Integrating two new technologies for faster response times and optimal performance
pH fast response glass membrane
(Patent pending)
01
New
Technology
The membrane contains HORIBA's unique combination of rare earth metals to improve response time by twofold and to increase durability against chemical substances.
Reference electrode with increased
02
New
Technology
ToupH electrodes are now even stronger
HORIBA’s glass membrane molding technology achieves strengths more than 10 times the Japanese Industrial Standards (strength tests).
Covering the internal electrode with a cation-conductive hollow fiber membrane, liquid junction clogging by silver ions and silver complex ions is reduced to 1/1000 of the conventional technology. Furthermore, maintained internal solution concentration ensures a stable standard electrical potential.
stability
(Patent pending)
New dome-shaped construction boosts strength in all directions !
7.40
7.20
pH
7.00
6.80
Respon se data fro m switching pH4 standa rd solut ion to tap water.
New electrode
Conventional
stability point
electrode stability point
New electrode
9615-10D
 (
Conventional
electrode
0 100 200 300
second
NEW
pH
NEW NEW
Pb
Free
water proof
STANDARD SLEEVE
9615-10D 9681-10D
General laboratory application
Buffer adjustment, general measurement
High viscosity application
Non-aqueous water, protein sample, food, and drinks
Pb
Free
water proof
(3-in-1) (Combination)
pH
Plastic Electrode 9625-10D
Pb
Free
water proof
Sleeve 6367-10D
For Food Analysis 6252-10D
pH ORP Temperature
Standard 6066-10C
For Extra-Thin Test Tubes 6069-10C
Needle Type 6251-10C
Flat Type 6261-10C
Metalic Electrode
Platinum 3-in-1 Type 9300-10D
water proof
Temperature Electrode
4163-10T
Conductivity Dissolved Oxygen
water proof
Flow Type 3561-10D
Flow Type 3562-10D
Flow Type 3573-10C
Flow Type 3574-10C
Field Use 9551-20D
(2 m Cable)
water proof
Field Use 9551-100D
(10 m Cable)
water proof
Immersion Type 3551-10D
1
Immersion Type 3552-10D
Immersion Type 3553-10D
Immersion Type 9382-10D
Laboratory Use 9520-10D
water proof
NEW
Pb
NEW NEW
water proof
MICRO LONG
9618-10D 9680-10D 0040-10D 0030-10D
Free
water proof
FL AT NEEDLE
water proof
water proof
Not just “unbreakable” . New flat sensor innovations allow the measurement of trace sample droplets or the measurement of solid sample surface.
What is an ISFET (semiconductor sensor) ?
ISFET is the abbreviation of Ion Sensitive Field Effect Transistor. The response membrane is equipped with semiconductor based sensor.
1. Will not crack or break like conventional glass electrodes
Special features of the ISFET
The flat electrode has less than a 100μm distance
between the housing and the sensor
The unique structure enables to measure miniscule amount of moisture on the surface of solid objects and prevents bubbles from trapping on the sensor when measuring samples in a beaker.
2. The sensor is flat and very small in size, enabling the measurement of extremely small samples
3. Easy handling and maintenance - simply clean with a toothbrush
4. Can be stored dry
Precious, trace amount sample
Direct measurement from micro tubes, only
50μL of sample
required
ION
Cyanide Ion Electrode
8001-10C
CN
Fluoride Ion Electrode
8010-10C
For large containers and long test tubes
283 mm length & 8 mm diameter
Chloride Ion Electrode
(Combination Type)
6560-10C
-
Silver Ion Electrode
8011-10C
-
CI
Surface of solid samples
Gel-like materials such as agar medium, foods such as meat, cloth and paper surface
Chloride Ion Electrode
8002-10C
-
CI
Ammonia Electrode
(Combination Type)
5002A-10C
Sulfide Ion Electrode
8003-10C
S
Sodium Ion Electrode
1512A-10C
Inside solid samples
Measurement inside the solid sample such as fruits, vegetables and bread
ISFET
Iodide Ion Electrode
8004-10C
-
2
Nitrate Ion Electrode
(Combination Type)
6581-10C
-
I
Bromide Ion Electrode
8005-10C
Br
Nitrate Ion Electrode
8201-10C
Effects of static electricity is reduced
The combination of HORIBA’s unique semiconductor device construction and improved static protection circuit means that the effects of static electricity, once the Achilles heel of semiconductor sensors, are greatly reduced.
Cu
+
2
Cadmium Ion Electrode
8007-10C
Cd
Potassium Ion Electrode
8202-10C
Copper Ion Electrode
8006-10C
-
Potassium Ion Electrode
(Combination Type)
6582-10C
Lead Ion Electrode
8008-10C
+
2
Calcium Ion Electrode
(Combination Type)
6583-10C
Response membrane(Gate)
+
2
Pb
Sectional drawing of tip of Flat I SFET
φ10 m m
Source Drain
Si substrate
Gap 100μm
Thiocyanate Ion Electrode
8009-10C
-
SCN
Calcium Ion Electrode
8203-10C
Reference electrode
Fluoride Ion Electrode
(Combination Type)
6561-10C
-
F
-
F
Ag
+
NH3 Na
+
NO3
-
NO3
-
+
K
+
K
Ca
+
2
Ca
+
2
2
LABORATORY
USP/EP/JP
USP/EP/JP
2CH
pH
mV(ORP)
ION
Conductivity
F-70Series DS-70Series
Intuitive and very easy to use touch panel operation
Simply slide your finger across the screen to switch displays
Resistivity
Salinity
TDS
2-channel can be displayed simultaneously
digital
flick flick
Color LCD display
NAVI 2CH USB
PRT ID
PC
USP/EP/JP
NAVI 2CH USB
PRT ID
PC
F-74 F-73
ION
ORP
CH.1
CH.2
pH
COND
RESI
SAL
TDS
CH.1
CH.2
pH
pH
ORP
ORP
graph analog
NAVI
PC
USB
PRT ID
F-72
ION
ION
CH.1
pH
ORP
ION
NAVI USB PRTPC
USP/EP/JP
ID
DS-72
COND
RESI
SAL
TDS
Loading...