IMPORTANT: Read carefully before assembly and use.
Welcome to
Hoover ownership.
Get cleaning confidence for up to 2 years
with the Hoover limited warranty.
Your Guide:
Safety Instructions
1
Carton Contents
How to assemble your Power Scrub Elite™
Features
Tools
Before you begin Cleaning
Getting started with your Power Scrub Elite™
Using your Power Scrub Elite™
Tools and Accessories
Maintenance
Hoover Cleaning Solution Guide
Troubleshooting
Warranty
3
4
5
7
8
9
13
15
21
23
26
27
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
When using an electrical appliance, basic precautions should always be
followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.
THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY.
IF USED COMMERCIALLY WARRANTY IS VOID.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DAMAGE OR INJURY:
• Fully assemble before operating.
• Operate cleaner only at voltage specied on data plate on lower back of
cleaner.
• Do not leave appliance when plugged in. Unplug from outlet when not in
use and before cleaning or servicing.
• Use indoors only.
• Do not immerse. Use only on carpet moistened by cleaning process.
• Use only HOOVER cleaning products intended for use with this machine.
• Do not allow to be used as a toy. Not intended for use by children age
12 and under. Close supervision is necessary when used near children.
To avoid injury or damage, keep children away from product, and do not
allow children to place ngers or other objects into any openings.
• Use only as described in this manual. Use only manufacturer’s recom
mended attachments and products.
• Do not use with damaged cord or plug. If appliance is not working as
it should, has been dropped, damaged, left outdoors, or dropped into
water, take it to a service center prior to continuing use.
1
• Do not pull or carr y by cord, use cord as a handle, close a door on
cord, or pull cord around sharp edges or corners. Do not place product
on cord. Do not run appliance over cord. Keep cord away from heated
surfaces.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not handle plug or appliance with wet hands.
• Do not put any object into openings. Do not use with any opening
blocked; keep free of dust, lint, hair and anything that may reduce air
ow.
• Keep hair, loose clothing, ngers, and all parts of body away from open
ings and moving parts.
• Turn o all controls before unplugging.
• Use extra care when cleaning on stairs. To avoid personal injury or
damage and to prevent the cleaner from falling, always place cleaner at
bottom of stairs or on oor. Do not place cleaner on stairs or furniture, as
it may result in injury or damage.
• Do not use to pick up ammable or combustible liquids, such as gasoline,
or ne wood sandings, or use in areas where they may be present.
• Connect to a properly grounded outlet only. See Grounding Instructions.
• Unplug before connecting SpinScrub
• Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
• Do not use without lters and tanks in place.
• Do not clean over oor electrical outlets.
®
powered hand tool.
WARNING: This product contains chemicals known
to the State of California to cause cancer, birth defects or repro-
ductive harm. WASH HANDS AFTER HANDLING.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This appliance is equipped with a cord having
an equipment-grounding conductor (C) and grounding plug (A). The plug
must be inserted into an appropriate outlet (B) that is properly installed and
grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in the risk of electric shock. Check with
a qualied electrician or service person if you are in doubt as to whether
the outlet is properly grounded. Do not modify the plug provided with the
appliance - if it will not t the outlet, have a proper outlet installed by a
qualied electrician. This appliance is for use on a nominal 120-volt circuit
and has a grounding plug that looks like the plug (A) illustrated in Fig. 1.
A temporary adapter (D) may be used to connect this plug to a 2-pole
receptacle (E) if a properly grounded outlet is not available (Fig. 2). The
temporary adapter should be used only until a properly grounded outlet (B)
can be installed by a qualied electrician (Fig. 1). The green colored rigid
ear, lug, or the like (F) extending from the adapter must be connected to a
permanent ground (G) such as a properly grounded outlet box cover (Fig.
2). Whenever the adapter is used, it must be held in place by a metal screw.
NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code.
B
A
21
D
D
G
E
F
C
CAUTION: TO REDUCE THE RISK OF DAMAGE:
• Avoid picking up hard, sharp objects with this product, as they may cause
damage.
• Store appropriately indoors in a dry place. Do not expose machine to
freezing temperatures.
• Do not use sharp objects to clean out hose as they can cause damage.
• To assist in reducing drying time, be certain the area is well ventilated when
using detergents and other cleaners with this machine.
• To help prevent matting and resoiling, avoid contact with carpets until they
are dry. Keep children and pets away from carpets until they are completely
dr y.
• Do not store extractor with solution in tanks.
• With brushes and brush roll on, do not allow cleaner to sit in one location
for an extended period of time, as damage to the oor can result.
• Do not use this extractor on hard oors. Using this machine on hard oors
may scratch or damage your oor.
• Water will drip from the brushes and underside of the product after use
and may puddle. To avoid damage to wood and laminate ooring and to
avoid potential slip hazard, after use (a) do not leave the product on wood
and laminate surfaces and remove to a hard surface and (b) place unit on
absorbent material (such as a towel) to soak up drips.
2
Carton Contents:
A.
F.G.
3
B.C.
H.
I.J.
D.
E.
K.L.
CARTON CONTENTS
A. Carpet Cleaner
B. Water/Solution Tank
C. Upper Handle
D. Handle Screws
E. SpinScrub
Assembly
F. Mesh Tool Storage Bag
G. Accessory Hose
H. Upholstery Tool*
I. Stair Tool*
J. Crevice Tool*
K. 2-in-1 Antimicrobial Tool*
L. Sample Bottle of Cleaning
Solution
*Tools vary per model.
Accessories not included with
your model may be purchased
separately by visiting Hoover.com
®
Brush
How to assemble your Power Scrub Elite™:
Insert the handle into the
base.
1234
Insert both screws and
tighten with a screwdriver.
Angle the Solution/Clean
Water tank above the
Dirty Water Recovery
Tank and click it into
place.
Wrap the power cord
around the cord hooks
for convenient storage.
4
Features:
14.
6.
7.
5
1. Water & Solution Trigger:
Press to release
1.
10.
15.
4.
3.
5.
9.
13.
8.
12.
11.
2.
2. ON/OFF Pedal
3. Wash/Rinse Mode Selector
4. Clean Water/Solution Tank
5. Dirty Water Recovery Tank
6. Dirty Water Recovery Tank
Latch
7. Solution Connection Port for
Hose
8. Nozzle
9. Hose Connection Port
10. Cord Storage Hook
11. Handle Release Pedal
12. Cord Clip
13. Cleaning Mode Dial
14. Clean Water Fill Port
15. Solution Fill Port
Features:
Cleaning Modes:
1. Turn the cleaning mode selection dial on the base of the unit to
choose your preferred cleaning mode. Align arrow to preferred
mode.
a. Quick Clean Mode: Best for a quick, surface clean because
carpets dry in less than 1 hour.
b. Deep Clean Mode: Best overall results for a thorough, deep clean.
Fig. AFig. B
6
Tools:
A.B.
C.D.
7
A. Stair Tool*: 6 inches wide with 2 built-in rows of bristles for cleaning
carpeted stairs.
B. Upholstery Tool*: 1 row of bristles for effectively cleaning upholstery.
C. Crevice Tool*: Great for use around baseboards and hard to reach
areas.
D. 2-in-1 Antimicrobial Tool*: Allows you to choose between two
inserts. The rubber nub insert is for unpleasant stain removal and
hygienic clean-ups. The bristle insert is for tough scrubbing power.
*Tools vary per model. Accessories not included with your model
may be purchased separately by visiting Hoover.com
Before you begin Cleaning:
Vacuum carpet and upholstery thoroughly with
a Hoover vacuum before use.
Don’t use the carpet cleaner as a traditonal
vacuum cleaner.
Use your Hoover carpet cleaner only if
upholstery fabric is marked with a “W” (for
“wet” clean) or “S/W” (for “solvent/dry” or “wet”
clean). Don’t clean fabric marked “S” (“solvent/
dry” clean only).
Test for colorfastness in a small, hidden area.
Gently rub surface with a dampened white
cloth. Wait ten minutes and check for color
removal or bleed with a white paper towel.
Move furniture out of area to be cleaned. Place
aluminum foil or wax paper under legs of
furniture too heavy to move to prevent wood
nishes from staining carpet. Pin up furniture
skirts and draperies.
Pretreat spots and heavy trafc areas with a
Hoover® Cleaning Solution*. See the “Cleaning
Solutions” section.
*Available at additional cost if not included with
your model.
Pretreating:
For best results, pretreat stains with a Hoover
spot treatment (see Hoover Cleaning Solution
Guide, pg. 23) to help loosen and remove even
the most stubborn stains.
NOTE: To prevent staining,
use plastic or aluminum foil
to protect wood or metal
surfaces from possible
water spray.
NOTE: To avoid damage
to wood oors underneath
area rugs or carpet, place
waterproof material (ex:
plastic) underneath them
before cleaning.
8
Getting started with your Power Scrub Elite™:
To fill the Clean Water/Solution Tank:
Press down on top
latch of clean water
1423
tank and pull to remove.
9
Twist off the clean water
cap on the top of the
clean water tank. Add
warm water to ll line and
replace cap. – DO NOT
BOIL OR MICROWAVE
WATER (Do not ll with
water above 140˚ F (60˚ C)
Twist off the solution
cap on the top of the
clean water tank and
pour cleaning solution
into tank. Replace cap.
Angle the Solution/
Clean Water tank back
on the base and click it
into place.
Getting started with your Power Scrub Elite™:
How to empty:Cord:
Unwrap the power cord
and plug unit in an
electrical outlet.
Turn the cleaner off and
unplug from electrical
outlet.
Release Dirty Water Tank
Latch.
Grab the Dirty Water
Tank handle and remove
312
from carpet cleaner
base.
10
Getting started with your Power Scrub Elite™:
Place on a at surface
and unlatch Dirty
Water Tank lid located
below the Quick
Spout Pour cap.
11
Empty tank, rinse
and allow to air dry.
54
IMPORTANT
!!
Be sure to replace the Quick Spout Pour Cap to
ensure proper suction.
IMPORTANT
!!
Regarding Dirty Water Tank Lid: For full suction it is
important that the Dirty Water Tank Lid is securely
in place. If misplaced, poor to no suction will result
(see Figs. E,F, G).
IMPORTANT
!!
For full suction, it is important that the Dirty Water
Tank is properly secured before cleaning.
Continue using dry strokes until little
water is visible passing through the
nozzle.
For best results, Hoover recommends
rinsing carpet with water only. This
removes residual carpet cleaning solution.
Fill Solution Tank with water and repeat.
For heavily soiled areas, repeat. Avoid
saturating carpet.
NOTE: Empty Dirty Water Tank when the
motor sound becomes higher pitched and
there is a loss in suction (see “Automatic
shut-off”). You will also see the oat rise
and shut off suction at the same time.
NOTE: It is best to alternate wet and dry
strokes as described above. See cleaning
modes section to choose best cleaning
mode for desired results.
CAUTION
Do not clean over oor electrical
outlets. Water will drip from the
brushes and underside of the product
after use and may puddle. To avoid
damage to wood and laminate ooring
and to avoid potential slip hazard,
after use (a) do not leave the product
on wood and laminate surfaces and
move to a hard surface and (b) place
unit on an absorbent material
(such as a towel) to soak up drips.
!!
12
Using your Power Scrub Elite™:
Choose cleaning mode
by turning the dial on the
1
base to “Quick Clean” or
“Deep Clean” mode.
NOTE: See cleaning mode
descriptions on page 6
13
Ensure Wash/Rinse dial
on the Clean Water Tank
is turned to “Wash”.
Plug into electrical outlet.
Step on the Power Pedal
342
to turn ON.
Step on the Handle
Release Pedal to recline
the unit for cleaning
position.
Using your Power Scrub Elite™:
Squeeze trigger to apply
water and cleaning
solution. Slowly push
forward then backwards
while squeezing the
trigg er.
Release the trigger and
slowly push forward. Then
675
slowly pull back toward you
without squeezing the trigger.
Continue pushing forward
and back without squeezing
the trigger until little water is
visible passing through the
nozzle.
For Best Results, Hoover
recommends rinsing the
carpet with clean water only.
This will remove residual
carpet cleaning solution from
your carpets. To Rinse with
clean water only, set the wash/
rinse dial to Rinse and then
repeat steps 5 and 6.
14
Tools and Accessories:
How to Attach Hose:
Read “Before You Begin
Cleaning” instructions.
Be sure to check Hoover®
Cleaning Guide on page 23
and the cleaning code on
your upholstery. Use your
cleaner only on upholstery
marked “W” or “W/S”.
CAUTION
To reduce risk of injury from
moving parts –
Unplug before servicing.
15
!!
Attach hose to the unit
by opening the Hose
12
Connection Port on the
nozzle. Insert hose end,
aligning the indicator with
the unlock arrows.
Rotate clockwise to lock
position.
Hold open the Hose
Solution Port door.
3
Tools and Accessories:
How to Attach Hose:
Plug the Hose Solution
Tube connector rmly into
4
the Hose Solution Port.
If additional cleaning is necessary, wait
until the upholstery is completely dry
before using the tool again.
Empty Dirty Water Tank when the motor
sound becomes higher pitched and there
is a loss in suction (see "Automatic Shutoff").
When nished cleaning, follow "After
Cleaning" and "After Using Tool"
instructions on page 19.
16
Tools and Accessories:
How to Remove Hose:
Disconnect Hose Solution
Tube from Hose Solution
123
Port by pulling up rmly. Do
not pull on tube, this may
cause damage. Port door
will automatically close.
17
Rotate hose end
counterclockwise from
the locked position to the
unlocked position and
remove by pulling out.
Snap the Hose Port Door
on the Nozzle back into
place. Make sure to snap
it rmly back into place to
ensure proper suction.
Tool and Accessories:
How to Attach Tools:
NOTE: Do not place unit
at top of stairway to avoid
falling down stairs.
Place unit at bottom of
stairs and work up.
To ensure maximum
performance and to
12
protect your carpet, be
sure to place the handle
in the upright position
while using the hose.
Placing the handle in the
upright position shuts off
the SpinScrub® brushes.
Connect tool to hose
by sliding it onto the
connector until it securely
locks into place.
Using your thumb, push
forward and up on the
3
latch to remove tool.
18
Tools and Accessories:
After Using Tools:
Drain hose by
removing the
1234
solution tank and
turning the cleaner
ON. Aim hose in a
downward angle
and press trigger
to remove excess
wate r.
Turn OFF cleaner.
Disconnect the hose
and solution tube
from cleaner.
Drain solution tube
by placing the round
end in the sink and
placing the tool
in sink. Press the
trigger to release air
and uid.
19
Replace hose and
tools in the Mesh
Tool Storage Bag.
CAUTION
Always turn off appliance
before connecting or
disconnecting hose.
!!