Owner's Manua|
Guide de rutilisateur
English ,-_ pp. 1-7
Platinum
Central Vacuum Systems
Syst_rnes d'aspJraUo.
centrale Platinum
Power Canisters
Aspirateurs centraux
This cleaner was inspected and packaged care-
fully before being shipped from the factory. If
you should happen to need assistance during
assembly or operation,
Call 1=800=944=9200 for automated referral of
authorized service outlet locations (U.S. only)
OR
Visit us on-line at hoover.corn to find the
service outlet nearest you (click on the
"Service" button) OR
Call 1-800-263-6376 to speak with a
representative in our Consumer Response
Center.
PLEASE DO NOT RETURN THIS
PRODUCT TO THE STORE.
,. j'
Frangais ,-_ p. 8-12
j
Cet aspirateur a et6 inspecte et emballe
soigneusement avant d'6tre expedi6 depuis
I'usine. Si vous avez besoin d'aide au cours de
I'utilisation ou de I'assemblage de I'appareil,
appelez :
Hoover Canada - 1=800=263=6376
Visitez notre site Web au hoover.ca. Cliquez
sur le bouton _ Service _ pour conna_tre
I'adresse du Centre de service le plus pres de
chez vous
PRI#RE DE NE PAS RETOURNER
CET APPAREIL AU D#TAILLANT.j
\
Review this manual before operating
Life attentivement ces instructions
avant d'utiliser I'appareil,
cleaner,

Index
Canister description .................... 3
Grounding instructions ............... 3
How to use .................................... 4
Important safeguards .................. 2
Maintenance ................................. 5
If you have a problem ............ 5
Where and how to install
the power unit ......................... 4
®
C US
©2007 The Hoover Company
hoover.corn
hoover.ca
Fi|| in and retain
The HOOVER Central Vacuum System Power unit will be permanently mounted.
For your records, please enter model and serial numbers in the spaces provided
below and retain in a safe place.
Power Unit Model No. Serial No.
(See side of power unit)
Attach your sales receipt to this owner's manual. Verification of purchase date
may be required for warranty service.
important Safegua !
When using an electrical appliance, always follow basic precautions, including
the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
m
among"inTo reduce the risk of fire, electric shock, or injury:
• Do not use on wet surfaces.
• Connect to a properly grounded outlet only. See "Grounding Instructions."
• Close supervision is necessary when any appliance is used by or near children.
Do not a|low cleaning system to be used as a toy or to run unattended at any
time.
• Do not allow any objects to be put into wall inlets.
• Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
• Do not use to pick up flammable or combustible liquids such as gasoline or fine
wood sandings or use in areas where they may be present.
• Do not use without filter in place. Empty dust container and clean filter
frequently when picking up very fine materials such as powder.
• Do not use without filter bag in place on models including a filter bag. Change
bag frequently when picking up very fine materials such as powder.
• Use extra care when cleaning stairs.
• Do not put any objects into openings. Do not use with any openings blocked:
keep free of dust, lint, hair, and anything that may reduce air flow.
• Do not pull or carry by cord, use cord as a handle, close a door on cord or pull
cord around sharp edges or corners. Do not run appliance over cord. Keep
cord away from heated surfaces.
• Always disconnect cord from electrical outlet before servicing the power unit.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Never handle plug or appliance with wet hands.
• Unplug cleaner when not in use. Turn off all controls before unplugging.
• Do not use with damaged cord or plug. If appliance is not working as it should,
has been dropped, damaged, left outdoors, or dropped into water, take it to a
Hoover Sales and Service Center or Authorized Hoover Warranty Service Dealer
(Depot).
• Use vacuum cleaner only for its intended use as described in this owner's
manual. Use only attachments recommended by Hoover; others may cause
hazards.
When using accessory kits, note these additional
Safeguards:
• Do not use powered nozzle outdoors.
• Keep hair, loose clothing, fingers, feet and all parts of body away from open-
ings, rotating agitator and any other moving parts. Do not operate nozzle in
bare feet or when wearing open toe shoes or sandals.
• Disconnect hose from wall inlet and cord from electrical outlet when not in use
and before servicing motorized nozzle.
• The hose contains electrical wires. Do not use if damaged, cut, or punctured.
Avoid picking up sharp objects.
• Always disconnect cord from electrical outlet before connecting or
disconnecting hose or motorized nozzle.
Save these instructions!

Operate cleaning system only at
voltage specified on power unit.
This system is intended for
household use.
Grounding
instructions
This appliance must be grounded. If it
should malfunction or breakdown,
grounding provides a path of least
resistance for electrical current to
reduce the risk of electric shock. This
appliance is equipped with a cord hav-
ing an equipment-grounding conductor
(A) and grounding plug (B). The plug
must be plugged into an appropriate
outlet (C) that is properly installed and
grounded in accordance with all local
codes and ordinances.
DANGER..
Improper connection of the equipment-
grounding conductor can result in the
risk of electric shock. Check with a
qualified electrician or service person if
you are in doubt as to whether the outlet
is properly grounded. Do not modify
the plug provided with the appliance -
if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
This appliance is for use on a nominal
120 volt circuit and has a grounding
plug that looks like the plug illustrated in
Fig. 1-1.
A Temporary adapter (D) may be used
to connect this plug to a 2-pole recepta-
cle (E) if a properly grounded outlet is
not available. The Temporary adapter
should be used only until a properly
grounded outlet (C) can be installed by
a qualified electrician. The green col-
ored rigid ear (F), lug, or the like extend-
ing from the adapter must be connected
to a permanent ground such as a prop-
erly grounded outlet box cover.
Whenever the adapter is used, it must
be held in place by a metal screw (G).
|
Q
C
|
NOTE: In Canada, the use of a tempo-
rary adapter is Not Permitted by the
Canadian Electrical Code.
D
F
Description
/
5/
/
/
j 2
1
15
11
1. Motor module
2. Motor exhaust port
3. Mounting bar
4. Dust container (contains
Items 11, 13, 14 & 15)
5. Filtration body
6. ON=OFF switch
7. Overload protector
8. Low voltage receptacle
(24 volt)
9. Power cord
10. Data label
11. Exhaust muffler
12. Hose inlet port
13.90 ° elbow
14. Mounting bracket
15. Vac cap
3

Location for power
canister
The Power Canister can be mounted in
the basement, utility room, garage or
any other remote area, except where
exposed to weather, and convenient to
an electrical outlet. The unit requires
ventilation. DO NOT install in a heat
producing or confined area such as the
attic, furnace room, etc. If desired, the
Power Canister can be exhausted to the
outside.
The top of the Canister should be no
less than 12" (30.5 cm) from the ceiling,
and any corner wall, to allow proper
cooling to the motor. For ease of remov-
ing the dust container, the bottom of the
unit should be at least 18" (46 cm)
above the floor.
Central Vacuum Power Canisters require
a separate/dedicated, 120 Volt, 60Hz.,
20 Amp, 3 wire grounded power circuit,
protected by a 120 Volt, 60 Hz., AC, 20
Amp time delay fuse or circuit breaker
and a 120 Volt, 60 mz., 20 Amp ground-
ed receptacle.
If a 120 volt, 60 Hz., 20 Amp grounded
receptacle is not available, have a quail-
fled electrician install one for you. The
receptacle should be no more than 5
feet (152 cm) from the Power Canister.
UNDER NO CIRCUMSTANCES
SHOULD AN EXTENSION CORD BE
USED WITH THIS CANISTER.
Mounting the power
canister
1) Determine if the wall you will be
mounting the Canister to is block,
concrete, or plaster/drywall.
2) Block or Concrete Wall
You will need (2) 1-1/2" (3.8 cm) x
1/4" (.64 cm) lead plugs and (2) 1-
1/2" (3.8 cm) x 1/4" (.64 cm) lag
bolts. Drill a 1/2" (1.3 cm) dia. x 1-
3/4" (4.4 cm) deep hole with a
masonry drill bit. Insert a lead plug
into the hole.
Mount the bracket (Fig. 2-1) from a
top hole with a lag bolt. Mark the
other upper hole of the bracket.
Make sure that the bracket is
straight. Slide the bracket away
from the mark and drill a hole direct-
ly over the mark.
Insert a lead plug into the hole.
Align the bracket over the hole and
tightly fasten with a lag bolt.
Continue to 4).
|
3)
Drywall or Plaster Wall
You will need(2) 1-1/2" (3.8 cm) x
a stud and drill a 1/8" (.32 cm) dia.
x 1-3/4" (4.4 cm) pilot hole. Mount
the bracket from a top hole with a
wood screw. Make sure that the
bracket is straight. Drill a second
pilot hole using a lower hole on the
bracket and fasten tightly with the
other wood screw.
Mount the Power Canister on the
4)
bracket making sure the bar on the
back of the machine is settled to the
bottom of the slots on the mounting
bracket. The wall mounting bracket
must fit between the two brackets
on the back of the central vacuum.
TOP
MOUNTING
BRACKET
1/4" (.64 cm) wood screws. Locate
5) Route the intake tubing to the
Canister.
6) Insert the tubing into the Canister
inlet.
7) Tighten the inlet connection with the
3" (7.6 cm) gear clamp (included).
(Do not cement pipe to plastic
inlet port.)
8) When venting the exhaust air, a
noise reducing exhaust muffler (A) is
included, which is installed inline in
the piping to vent outside or it can
be installed to vent indoors as
shown in Fig. 2-2. Connect to the
exhaust (right hand side near to of
unit). Tighten the exhaust connec-
tion with the gear clamp (included).
(Do not cement pipe to plastic
exhaust port.)
9) Connect the 24 Volt wires coming
from the wall valves into the 24 Volt
receptacle on the machine.
10) Plug the power cord in.
11) Assuming that the wall inlet valves
are connected, the system is now
ready.
A B
To start your Power Canister, simply plug
your hose end into any wall inlet valve.
Both types of wall valves (Standard (A) -
Corded Hose; Electrified (B) - Cordless
Hose) are shown in Fig 3-1.
Hose inlet port
Insert the hose into the hose inlet (A) as
shown in Fig. 3-2. The power unit is
turned ON and OFF with the switch
found on the upper section of the motor
module.
JA
If you have a hose without switches, the
Power Canister will start as soon as the
hose is inserted into the wall valve.
If you have a hose with a switch, then
the Power Canister can be turned ON or
OFF with the switch.
The Power Canister can also be turned
ON and OFF with the switch found on
the upper section of the motor module.
Check the System
Check each connection for proper seal
and that no air leaks occur. If one is pre-
sent, you may hear a "hissing" sound.