Hoover Ground Command User Manual

Hoover Inc.
New Equipment Warranty
Limited Warranty
Hoover Inc. warrants new equipment against defects in material and workmanship under normal use and service to the original purchaser. Any statutory implied warranties,
including any warranty of merchantability or tness for a particular purpose, are
expressly limited to the duration of this written warranty. Hoover Inc. will not be liable for any other damages, including but not limited to indirect or special consequential damages arising out of or in connection with the furnishing, performance, use or inability to use the machine. This remedy shall be the exclusive remedy of the purchaser. The warranty period is subject to the conditions stated below.
1 Year - Chassis, Motor, Fan and Electrical Components
Hoover, Inc, warrants the plastic chassis to be free of defects in materials and workmanship for one (1) year. Hoover Inc. warrants the ½ HP electric motor to be free of defects in materials and workmanship for one (1) year, under normal use and service sold to the original purchaser. Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period. Service labor charges are covered for one (1) year from the date of purchase, when performed by a Hoover-authorized service provider. Freight charges to and from this service provider will be covered for 90 days from the purchase date. After this 90 day period, these freight charges will be paid by the equipment owner. Travel expenses are not covered.
Normal wear items such as capacitors, cords, nishes or switches will not be warranted
for manufacturing defects for 90 days from the purchase date.
All warranties of motors and associated components will be voided; if the Air Mover is serviced by anyone other than a Hoover-authorized service provider; if the machine is
mechanically modied; or if the machine is misused or abused.
The warranty starts on the purchase date by the original purchaser from an authorised Hoover Inc. distributor, subject to proof of purchase. The machine registration card must be completed and returned immediately at the time of purchase. If proof of purchase
cannot be identied, the warranty start date is 90 days after the date of sale to an
authorized Hoover, Inc. distributor.
Hoover, Inc.
7005 Cochran Road Glenwillow, Ohio 44139 (888) 321-1 134 For Service, Ask for Tech. Service Dept, ext. 2554
www.hoover.com
© 2010 Copy Rights Reserved Hoover, Inc.
Design and Engineering
The • ½ HP, 2200 CFM motor gives ample power for drying surfaces and moving musty air.
streamattheoortomove
air and dry carpets, or tip back to dry curtains, walls and ceilings. Stack up to 3 air mover units for easier storage.• A balanced design with molded carrying handle makes transportation easy.• 20 foot long power cord.•
the powerful, steel fan blades. Lifetime warranty on roto-molded chassis. 1 year on electrical components.•
Motor Fan Size 9.5” Steel Blade and Frame Air Flow Rate up to 2200 CFM Chassis Molded High-Density Polypropylene Power Cord 20 Foot Power Cord Dimensions 19.5” H x 19.2” L x 14.5” W Shipping Weight 33 lbs. Warranty Lifetime on Body. 1 Y ear on Electrical Components
© 2010 Copy Rights Reserved Hoover, Inc.
½ HP, 2200 CFM Air Mover
Powerful High Airow
Dries Hard Floors, Carpets,
Walls and Ceilings!
Specications
1
/2 HP, 1 15 V
#961130010- 9/10- Rev1
1.0 Safe Operating Conditions
READ THIS MANUAL BEFORE USING AIR MOVER. KNOW THE PROPER OPERATION, CORRECT APPLICATIONS AND THE LIMITATIONS OF THIS EQUIPMENT BEFORE USE.
Reduce the Risk of Fire, Electric Shock or Injury:
This Air Mover must be grounded. See section 1.2 for more details. This Air Mover is designed for commercial use. It is constructed for indoor use and its not intended for any other use.
Do not use in ammable or explosive areas. Never • operate this Air Mover near ammable or explosive
dusts, liquids or vapors. Do not use with damaged cord or plug. Do not use outdoors. Do not expose to rain. Do not use in standing water. Do not use Air Mover if it not operating properly. Report problems to a supervisor. Do not use with an extension cord. Wipe the chassis of the Air Mover to clean. Use vacuum
to remove dusts from screen. Do not wash with owing
water. Do not use this Air Mover unless trained.
Figure 1
Figure 2
Reduce the Risk of Fire, Electric Shock or Injury:
Do not run any machines over the cord. Do not pull Air Mover by cord or plug. Do not pull cord around sharp edges or corners. Do not unplug by pulling on the cord. Do not stretch cord. Do not handle plug with wet hands. Keep cords away from hot surfaces. Do not allow Air Mover intake to collect burning or smoking debris, such as cigarettes, matches or hot ashes.
Do not move air with ammable or explosive chemicals.
Keep the air intake free of debris. Do not operate with the intake covered or blocked.
(2) Air Mover Air Mover (7)
2.0 Operating Tips
Dry Floors and
Carpets
Move Musty Air
Dry Walls and Curtains
Dry
Ceilings
For indoor use only.•
Adjust the Air Mover to the desired position for operation by tipping the machine onto one
of the three at faces of the heavy duty plastic
chassis. The balanced machine design assures stable positioning. Plug the power cord into a grounded outlet. This Air Mover has three (3) power settings controlled at the side of the machine. Turn the power knob on the side of the Air Mover to the desired speed. 1 = 780 RPM. 2 = 1000 RPM. 3 = 1100 RPM. To turn the Air Mover off, turn the power knob to the off position. Never pull on the cord to disconnect or turn off the motor.
3.0 Storing the Air Mover
Wind the cord around the carrying handle. Store in the upright position in a dry area. Check and clean after each operation. Remove soil and chemical buildup. Use vacuum and soft brush to remove soils from motor vents and fan blades. Wipe the outside chassis with a mild cleaner. Never wash the outside of the Air
Mover with owing water. Make sure that the air intakes are not blocked.
Check switches for proper operation. Call a trained electrician to repair or replace damaged cords and plugs. Report problems and repair promptly.
4.0 Troubleshooting
Never operate this Air Mover when the equipment is not performing as expected or when any part is visibly damaged. When repair is needed, take the equipment to an authorized service center.
4.1 Air Mover will not run
Circuit breaker tripped in building. • Check and reset. Equipment unplugged. • Check plug at wall and plug in. Power cord failure. • Seek authorized repair services. Motor sparks or smokes.• Seek authorized repair services.
4.2 High Vibration
Air Mover fan blades are damaged or broken. • Seek authorized repair services. Motor bearings are worn. • Unplug the Air Mover and spin the fan blades. If the
spinning causes noise or restricted movement, replace the Air Mover with new equipment.
(6) Air Mover
1.1 Air Mover will not run
This Air Mover operates on a 15 amp nominal 115V, 60 Hz, A.C. power circuit. The, amp, hertz and voltage ratings are listed on the motor spec label found on each Air Mover. Using voltages above or below those indicated on the spec label will damage the motor. Always check your local voltage requirements.
1.2 Grounding Instruction
This Air Mover must be grounded while in use to protect the operator from electric shock. This machine is built with a 3-wire cord and a
3-pronggrounding-typeplug(Figure1)tota
properly grounded receptacle.
Before using this machine, make sure a properly grounded, 3-hole electrical outlet is available. If not available, as in some older facilities, use
Figure 1
an adapter for connecting a 3-prong plug to a 2-prong receptacle (Figure 2) to ground the outlet chassis.
IMPORTANT!! This adaptor may not be used in Canada.
IMPORTANT!! Never cut off the grounding prong for use in a 2-prong outlet. By doing so, you have cut off your protection from electrical shock.
Never assume that all 3-hole outlets are properly
Figure 2
grounded. Check before use.
Never assume that an adaptor connection (as in Figure 2) is properly grounded. Check the outlet with a ground fault interrupter device which quickly indicated if a ground is connected.
Correct a faulty grounding before proceeding.
1.3 Extension Cords are Not Recommended
The Air Mover is built with a 25 foot safety cord. Use of any extension cords is NEVER RECOMMENDED.
Air Mover (3)
½ HP, 2200 CFM Air Mover
Fan Wheel (1)1. Motor 2. ½ HP (1) Motor Bolts (4)3. Rotary Switch (1)4. Switch Housing (1)5. Motor Screen (1)6. Finger Guard (1)7. Power Cable w/ plug - 20 ft. (1)8. Intake Screen (1)9. Venturi Ring (1)10. Venturi Rivents (8)11.
(4) Air Mover
Air Mover (5)