When using an electrical appliance, always follow basic precautions, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
Warning: To reduce the risk of fire, electric shock, or injury:
•Do not use outdoors or on wet surfaces.
•Connect to a properly grounded outlet only. See “Grounding Instructions”.
•Close supervision is necessary when any appliance is used by or near
children. Do not allow vacuum cleaner to be used as a toy or to run unat
tended at any time.
•Keep hair, loose clothing, fingers, feet and all parts of body away from
openings, rotating agitator and other moving parts. Do not operate cleaner in
bare feet or when wearing open toe shoes or sandals.
•Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
•Do not use to pick up flammable or combustible liquids such as gasoline or
use in areas where they may be present.
•Avoid picking up hard, sharp objects with the cleaner. They may damage the
cleaner or the bag.
•Do not use without dust bag or dirt cup in place. Change throw away bag or
shake outer bag and empty dirt cup frequently when picking up very fine
materials such as powder.
•Use extra care when cleaning on stairs.
•Do not put any object into openings. Do not use with any opening blocked;
keep fee of dust, lint, hair, and anything that may reduce air flow.
•Do not pull or carry by cord, use cord as a handle, close door on cord or pull
cord around sharp edges or corners. Do not run appliance over cord. Keep
cord away from heated surfaces.
•Always disconnect cord from electrical outlet before servicing the cleaner.
•Unplug cleaner when not in use. Turn off all controls before unplugging.
•Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Never handle plug or appliance with wet hands.
•The use of an extension cord is not recommended. If an extension cord is
absolutely necessary, use at least a 16 gauge 3-wire cord which has a 3-prong
grounding type plug and a 3-pole receptacle that accepts the machine plug.
•Do not use with damaged cord or plug. If appliance is not working as it
should, has been dropped, damaged, left out-doors, or dropped into water,
take it to a Hoover Factory Service Center or Authorized Hoover Commercial
Warranty Service Distributor.
•Use vacuum cleaner only for its intended use as described in this owner’s
manual. Use only attachments recommended by The Hoover Company; oth
ers may cause hazards.
DOUBLE INSULATED
When servicing use only identical replacement
parts.
This cleaner meets Occupational Safety and
Health Act (OSHA-29 CFR 1910 Subpart S)
requirements.
reassembly, if necessary. Washer
must be placed between agitator ends
and bearing.
1. Brush roll core
2. Flat sided projection
3. End plate
4. Bearing
5. Washer
5
6
Lubrication
The motor is equipped with bearings which
contain sufficient lubrication for the life of
the motor. The addition of lubricant could
cause damage. Do not add lubricant to
motor bearings.
The agitator is equipped with two ball
bearings that should be lubricated periodically by a Hoover Factory Service Center or
an Authorized Hoover Warranty Service
Dealer.
Service
To obtain approved HOOVER service
and genuine HOOVER parts, locate the
nearest Hoover Factory Service Center
or Authorized Hoover Warranty
Service Dealer (Depot) by:
• checking the Yellow Pages under
“Vacuum Cleaners - Household”
OR -
• checking the list of Factory Service
Centers provided with this cleaner
OR -
• calling 1-800-944-9200 for an
automated referral of authorized
service outlet locations (U.S. only)
Do not send your cleaner to The Hoover
Company in North Canton for service,
this will only result in delay.
If further assistance is needed, contact
The Hoover Company Consumer
Response Center, North Canton, Ohio
44720 Phone: 1-330-499-9499.
Always identify your cleaner by the
complete model number when requesting information or ordering parts. (The
model number appears on the bottom of
the cleaner.)
8
9
6. Agitator end
7. Shaft
8. End section
9. Agitator end
10. Washer
11. Bearing
12. End plate
13. Round projection
10
Servicing of
double-insulated
appliances
This vacuum cleaner is double insulated.
In a double-insulated appliance, two
systems of insulation are provided instead
of grounding. No grounding means is
provided on a double-insulated appliance,
nor should a means for grounding be
added. Servicing a double-insulated
appliance requires extreme care and
knowledge of the system, and should be
done only by qualified service personnel.
Replacement parts must be identical to
those parts being replaced. A double-
insulated appliance is marked with the
words “DOUBLE-INSULATION” or
“DOUBLE-INSULATED”. The symbol
may also be marked on the appliance.
13
If you have a
problem
If a minor problem occurs, it usually can be
solved quite easily when the cause is found
by using the checklist below.
Problem: Cleaner won't run
Possible Cause
Possible Solution
• Not firmly plugged in.
• Plug unit in firmly.
• No voltage in wall plug.
• Check fuse or breaker.
• Blown fuse or tripped breaker.
• Replace fuse or reset breaker.
Problem: Cleaner won't pick up
Possible Cause
Possible Solution
• Broken or worn belt.
• Replace belt.
• Agitator brush roll worn.
• Replace brush roll.
• Bag full.
• Change paper bag.
• Incorrect carpet height setting.
• Move nozzle control knob to type of
carpet being cleaned.
Problem: Cleaner hard to push
Possible Cause
Possible Solution
• Incorrect carpet height setting.
• Move nozzle control knob to a higher
setting.
Page 6
32
A
The agitator
Disconnect cleaner from electrical
outlet before checking or replacing
brushes.
What to buy
When purchsing a new brush roll
(assembly complete), ask for HOOVER
part No. 48414040.
When replacing brush roll core only, ask
for HOOVER part No. 4841048.
33
Stretch new belt onto motor pulley
32
(A).
Extra effort may be required to stretch
belt onto pulley.
Turn agitator, making sure belt is not
pinched between agitator and cleaner
body. The belt must rotate freely inside
the belt guide. If the agitator does not
turn, remove bottom plate and reposition
belt in the belt guide.
Replace hood and nozzle control knob.
How to replace
brush roll – assembly
complete
Disconnect cleaner from electrical
outlet.
1. Remove hood as shown in Figs. 29-31
of “How to replace belt.”
2. Pull belt off motor pulley (A) shown in
Fig. 32..
3. Remove bottom plate and agitator as
shown in Figs. 25-26.
4. Remove agitator from cleaner and
discard.
5. Reposition belt and new agitator
beginning with Fig. 27.
How to replace
brush roll – core only
Disconnect cleaner from electrical
outlet.
Remove bottom plate and agitator as
shown in Figs. 25-26.
When to replace
To check condition of brushes, move
33
edge of a card across bottom plate
while turning agitator. Replace agitator if
brushes do not touch card.
Note: The agitator belt should be
repalced each time the brush roll is
replaced.
34
END PLATES
Turn end plates of agitator in
34
opposite directions until one end
plate comes off.
35
Pull out shaft part way being
35
careful to leave washer on shaft.
Reinsert shaft to push out opposite
agitator end.
Repeat in other direction to push out
second agitator end.
Discard old agitator brush roll.
36
Place agitator ends into new brush
36
roll, matching projections in brush
roll with openings in ends.
Push ends firmly into place. (If bearing
comes out of agitator end during disassembly, place washer and bearing back
into agitator end, with white side of
bearing out, before inserting shaft.)
Insert shaft (with washer ) into agitator.
Replace end plate and tighten.
Note: Be sure shaft is inserted so that
end plate with flat-sided projection is
screwed onto belt end of agitator roll.
Replace agitator and belt beginning with
Fig. 27.
Continued➜
7
Page 7
The belt
25
26
What to buy
Use only genuine HOOVER belt, part No.
38528-027 with your cleaner.
When to replace
Disconnect cleaner from electrical
outlet.
To check belt, remove bottom plate and
hood as shown in “How to replace belt.”
Replace belt if it is stretched, cut or
broken.
27
D
A
A
BC
How to replace
Disconnect cleaner from electrical
outlet.
Place handle in lowest position.
25
Turn cleaner over and remove the
two bottom plate screws (A).
To remove bottom plate, insert end of
flat screwdriver into wide area of righthand slot (B) and push handle of
screwdriver to the rear. Repeat in lefthand slot (C).
Lift extension (D) of bottom plate, rotate
plate and remove from cleaner body.
28
Remove agitator and broken
26
agitator belt.
529
C
B
Slip agitaor through new belt (with
27
lettering toward outside of
cleaner) and position belt in belt guide
(A).
Push end of belt into opening in cleaner
body.
Reposition agitator making sure to align
flat sides of of projection (B) on belt end
of agitator with flat sides of slot (C) in
cleaner body.
A
30
Place the three tabs on bottom plate
28
into slots in front of cleaner body.
Snap bottom plate into place over
agitator.
Remove hood by turning cleaner
29
over and removing nozzle control
knob on front of hood – grasp knob and
pull up.
31
Place handle in operating position
30
and turn cleaner over. Insert end of
flat screwdriver into one of the four slots
beside an arrow on bottom of cleaner.
6
For slots nearest rear wheels, push
handle of screwdriver toward cleaner
handle; for remaining two slots, pry
outward to release latches.
Turn cleaner over and lift off hood.
31
Page 8
18
A
19
20
A
B
Carpet height
adjustment
The cleaning of carpet and rugs
18
takes place at the nozzle (A).
21
21
settings are recommended.
Cleaners with Two settings:
• Setting 1 (A): for bare floors and all
carpet types
• Setting 2 (B): if easier pushing effort is
desired while maintaining good
cleaning performance.
Cleaners with Four Settings:
• Lowest setting (1): for bare floors and
low pile, level loop, kitchen type
carpet.
• Next setting (2): for other types of
carpet.
• Higher settings (3-4): for very deep
pile carpet where easier pushing effort is
desired, while maintaining good cleaning
performance.
Note: If the cleaner is difficult to push,
slide knob to the next higher setting.
(A)
(1)
For maximum cleaning performance, the following carpet height
(2)
(B)
(3)
(4)
If it is necessary to raise and lower
19
the nozzle for various carpet pile
heights, slide the nozzle control
knob to the desired setting.
22
Edge cleaning
Edge cleaning is provided on both
22
sides of nozzle to remove dirt in
carpet near baseboards and furniture.
Guide either side of nozzle parallel to
edge of carpet or furniture.
For ease in sliding knob, the handle
20
should be in the upright position
(A).
The nozzle will not move into the
adjusted position until the cleaner
handle is lowered to the operating
position (B).
23
Belt storage
Lift door to conveniently store extra
23
belt.
Maintenance
Disconnect cleaner from electrical
outlet before attempting to service it in
any manner.
The filter bag
When to replace
Check bag from time to time. It is
recommended that you change the
paper bag when dirt reaches the dotted
line. If more dirt than this accumulates,
your cleaner may not operate effectively.
CAUTION: Very fine materials, such as
face powder, cornstarch, fireplace
ashes or fireplace soot, may seal the
paper bag and may cause it to burst
even though it is only partially full of
dirt. When cleaner is used to remove
material of this nature, change bag
often.
What to buy
For improved cleaning effectiveness, use
only Genuine HOOVER® AllergenFiltration Type A disposable bags.
Regular HOOVER® bag Type A disposable bags also fit your cleaner.
How to replace
Disconnect cleaner from electric outlet.
To change paper bag, unzip outer
24
bag, grasp sides of bag collar (A)
and pull collar from tube.
Note: Do not clean out old bag and
reuse. Discard used bag.
24
B
A
Hold new bag as shown. Align opening
in paper bag with dirt tube (B). Push (A)
firmly onto (B). Tuck in paper bag; zip
outer bag.
5
Page 9
13
A
14
15
B
C
D
Place nut (A) in recessed area at
13
back of handle. Hold nut in place
while tightening bolt securely with a
screwdriver.
Note: Only one nut is needed on this
model. The extra nut is not required but
has been provided for your convenience.
STEP 6 Attach paper bag
16
A
Hold paper bag collar (A) as shown.
16
Align opening in paper bag with dirt
tube (B) inside the outer bag.
Push bag collar firmly onto (B).
Tuck in paper bag; zip outer bag.
B
A
On upper front handle, grasp bag
14
clip (B) and pull down firmly. Hook
bag clip into slot in bag cap.
CAUTION: When the cleaner is turned
ON, the agitator continues to rotate
while the handle is in the upright
position.
Pull white switch lock above ON-
15
OFF switch straight out.
Dispose of lock.
Note: If lock has come off during
assembly, make sure switch is in the
OFF position (down) before plugging
cord into electrical outlet.
Cleaner description
17
12
11
10
4
1
2
3
4
5
6
7
8
9
The assembled cleaner will look like
17
the drawing.
1. Handle
2. ON/OFF switch
3. Cord hooks: wrap cord around hooks
for storage. The top hook can be
rotated right or left for easy cord
release
4. Bag cap
5. Outer bag
6. Stair cleaning handle:located on
lower edge of bag.
7. Handle release lever: step on
lever to lower handle to operating or
low position.
8. Cleaner body
9. Nozzle control knob: slide knob to
correct setting for height of carpet
being cleaned.
10.Furniture guard: helps prevent
cleaner from marking furniture.
11. Hood
12. Extra belt storage: open door to
store extra belt.
How to use
Operate cleaner only at voltage
specified on data plate on bottom of
cleaner.
WARNING: electrical shcock could
occur if used outdoors or on wet
surfaces.
To reduce the risk of electric shock, this
appliance has a polarized plug (one
blade is wider than the other). This plug
will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit,
contact a qualified electrician to install
the proper outlet. Do not change the
plug in any way.
ON-OFF Switch
To turn cleaner ON, push switch up.
To turn cleaner OFF, push switch down.
.
Page 10
4
H
F
5
J
H
I
F
K
I
F
Rotate cord protector (F) on cord
4
until you see its arrow (H).
6
Press cord into place at each of the
6
three notches indicated and note
correct positioning of (F).
Do not plug cleaner in until assembly
is totally complete.
8
A
With arrow (H) on (F) pointing
5
toward arrow (H) on (I), press groove
(J) into slot (K).
Pull cord tight.
F
9
STEP 4 Attach cloth
outer bag
7
B
A
Note location of tapered rails (A) on
7
back of outer bag base (B) and on
front of lower handle (C).
10
G
F
C
B
D
C
Slide rails on (B) onto rails on (C)
8
until (B) snaps past the lock tab (D).
STEP 5 Attach handle
11
E
B
D
The hole (E) in handle is visible
9
through U-shaped extension on (B)
when (B) is in position past (D).
Be sure that power cord is pulled tight
and pressed into each of the three
notches (Fig. 6) before completing the
following steps.
With outer bag to the front, place
11
assembled handle onto handle base
of cleaner body.
Rock handle side to side while pushing
down firmly. Extra pushing effort may
be required.
Press the handle release lever to move
handle to the operating or middle
position.
Push bolt into hole on lower front of
12
handle.
If bolt will not go through hole easily
handle is not pushed completely down.
H
I
Note round opening (F) and hooks
10
(G) on back of outer bag (H).
Place opening over dirt tube (I).
Unzip (H) and place hand inside. Press
down firmly to snap hooks into handle.
12
Continued➜
3
Page 11
Assembling cleaner
STEP 1 Unpack carton
It is extremely important
to read and
follow all instruction
steps in order.
STEP 2 Assemble handle
2
D
1
A
B
Remove all parts from carton and
1
identify each item shown. Make
sure all parts, especially small items,
such as G, are located before
disposing of cardboard packing.
C
DG
Note: The white switch lock above the ON-OFF (A)
switch helps in the assembly of your cleaner. Assembly
can be continued if the switch lock is missing. However,
do not remove the switch lock until assembly is completed.
F
E
A. Upper handle
B. Lower handle
C. Cord
D. Outer bag
F. Cleaner body
G.Handle bolt and nut packet
(one extra nut included)
H. Paper bag
A
C
Align upper handle and lower
2
handle as shown.
Place upper (B) and lower (C) handle
parts on a flat surface, aligning rod
sections (D). With hand on sides of
handle, push parts together firmly until
they "click" and rod sections lock
together.
STEP 3 Attach cord
3
E
3
with side marked “UP” visible.
Make sure rectangular end is pushed into
handle as far as possible.
Slide cord protector (F) toward upper
handle (G).
"UP"
Insert large rectangular end of cord
into pocket in bottom of handle,
F
B
*Do not press against the grey rod
extending from the lower handle Fig. 3
and 4 (E). Do not push handle together
with hands on ends of sections.
"UP"
G
E
2
Page 12
HOOVER
Lightweight
Commercial
Cleaner
Review this manual
before
operating cleaner
Index
Assembling Cleaner......................... 2-4
Cleaner Descriptions ...........................4
How To Use....................................... 4-5
DOUBLE INSULATED
When servicing use only identical replacement
parts.
This cleaner meets Occupational Safety and
Health Act (OSHA-29 CFR 1910 Subpart S)
requirements.
Owner’s Manual
English, Spanish
Record and retain
Model ____________ Serial No. _______________
(located on bottom of cleaner)
Important Safeguards!
When using an electrical appliance, always follow basic precautions, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
Warning: To reduce the risk of fire, electric shock, or injury:
•Do not use outdoors or on wet surfaces.
•This appliance is provided with double insulation. Use only identical replacement parts. See instructions for servicing of Double-Insulated Appliances.
•Close supervision is necessary when any appliance is used by or near
children. Do not allow vacuum cleaner to be used as a toy or to run unat
tended at any time.
•Keep hair, loose clothing, fingers, feet and all parts of body away from
openings, rotating agitator and other moving parts. Do not operate cleaner in
bare feet or when wearing open toe shoes or sandals.
•Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.
•Do not use to pick up flammable or combustible liquids such as gasoline or
use in areas where they may be present.
•Avoid picking up hard, sharp objects with the cleaner. They may damage the
cleaner or the bag.
•Do not use without dust bag or dirt cup in place. Change throw away bag or
shake outer bag and empty dirt cup frequently when picking up very fine
materials such as powder.
•Use extra care when cleaning on stairs.
•Do not put any object into openings. Do not use with any opening blocked;
keep fee of dust, lint, hair, and anything that may reduce air flow.
•Do not pull or carry by cord, use cord as a handle, close door on cord or pull
cord around sharp edges or corners. Do not run appliance over cord. Keep
cord away from heated surfaces.
•Always disconnect cord from electrical outlet before servicing the cleaner.
•Unplug cleaner when not in use. Turn off all controls before unplugging.
•Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Never handle plug or appliance with wet hands.
•The use of an extension cord is not recommended. If an extension cord is
absolutely necessary, use at least a 16 gauge cord and as short as possible.
•Do not use with damaged cord or plug. If appliance is not working as it
should, has been dropped, damaged, left out-doors, or dropped into water,
take it to a Hoover Factory Service Center or Authorized Hoover Commercial
Warranty Service Distributor.
•Use vacuum cleaner only for its intended use as described in this owner’s
manual. Use only attachments recommended by The Hoover Company; others may cause hazards.