Hoover 33800317, 33800316, 33800315, 33800318, 33800319 User Manual

...
0 (0)

GB

INSTRUCTIONS FOR USE AND INSTALLATION

IT

ISTRUZIONI D’USO E DI INSTALLAZIONE

PT

MANUAL DE UTILIZAÇÃO E DE INSTALAÇÃO

 

~~~

41016047

1

All these characteristics are given for information with a constant concern for improving

production quality, the manufacturer may make modification to the appliance to incorporate

technical improvements.

 

The hobs are in conformity with directives 89/336/CEE, 73/23/CEE and

90/396/CEE.

 

CONTENTS

 

Unpacking the appliance ......................................................................

2

Recommendations ...........................................................................

2-3

Hob features ........................................................................................

3

• INSTALLATION

 

Safety instructions ...............................................................................

4

Modification of the factory gas setting :

 

* Fitting of the correct jets ....................................................................

5

Fitting the hob ......................................................................................

6

Gas connection ....................................................................................

7

Electrical connection ............................................................................

8

After final installation of the hob (if modification of the gas setting) :

 

Adjusting of the lower flame on the gas burners...................................

9

• USING THE APPLIANCE

 

The different gas burners ....................................................................

10

Igniting and setting the burner .............................................................

11

The hot plate - some tips...............................................................

12-13

General maintenance ....................................................................

14-15

UNPACKING THE APPLIANCE

 

Inside the appliance, you will find :

• a plastic bag containing :

-the new jets for the gas modification, if required,

-according to model, a cylindrical connector and/or a conical connector with seal for the gas connection,

-the fixing brackets with screws required for installing the hob in the worktop.

RECOMMENDATIONS

TO GET THE BEST FROM YOUR APPLIANCE, PLEASE READ THE FOLLOWING CAREFULLY.

Please keep the operating and installation instructions in a safe place for future reference. Before fixing the hob, note the serial number of the appliance just in case you should require future repairs from our after sales service organisation at some time in the future.

2

Hoover 33800317, 33800316, 33800315, 33800318, 33800319 User Manual

. Rating plate (located under the lower casing of the hob)

All accessible parts of the hob will become hot while in operation. Always keep children away from it.

The hob should be given a quick clean after each use, to avoid the accumulation of spillages and grease. If spillages are not removed, they will harden, and could cause the production of smoke and unpleasant smells.

When cooking with fats or oils, never leave gas burner unattended. Overheated fats or oils can quickly catch fire.

HOB FEATURES

MODELS 60 cm

 

 

MODELS 75 cm

 

 

 

 

 

3

INSTALLATION

Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect consumer safety.

It is for this reason that the task should be undertaken by a professionally qualified person who will carry it out in accordance with the technical regulations in force.

In the event that this advice is ignored and the installation is carried out by an unqualified person, the society declines all responsibility for any technical failure of the product whether or not it results in damage to goods or injury to individuals.

Before installing the hob :

make sure that the appliance is compatible with the gas supply source.

The hob is pre-set in the factory to work with the type of gas shown on the packing and the plate attached to it.

Natural gas G 20-20 mbar / G 25-25 mbar : mains gas

if necessary, adapt the hob for use with another type of gas : if the hob must be used with another type of gas than the gas pre-set in the factory, it is necessary to adapt the hob gas burners (page 5).

The procedure for adaptation consists of :

. fitting the correct jets to ensure nominal delivery.

For installation,

built-in hob (page 6).

make the gas connection according to the type of gas to be used : based on the gas to be used, choose the appropriate gas connection (page 7).

make the hob electrical connection according to the instructions (page 8).

adjusting the minimum flame of the taps : if necessary, adjust the minimum flame of the taps by turning the by-pass screw (page 9).

All modification concerning the hob gas setting must be indicated on the rating plate of the hob.

4

INSTALLATION: «GAS CONNECTION»

 

GAZ/GAS

G20

G25

G 30

G 31

 

 

 

 

 

 

 

 

20 mbar

25 mbar

29 mbar

37 mbar

 

 

 

 

 

 

CAT. II2H3+

GB-IT-PT-ES

¤

 

X

X

 

 

 

 

 

 

CAT. II2E+3+

FR

¤

¤

X

X

 

 

 

 

 

 

¤ = Factory setting: Natural gas = G20-20 mbar / G25-25 mbar

X = Gas setting possible according to installation Butane gas G30-29 mbar or Propane gas G 31-37 mbar

CHANGING THE GAS TYPE : the calorific power output and gas pressure will vary according to the gas supply. Burner setting must be carried out once the gas and electrical installation is complete.

When changing gas type, you must follow the procedure below :

. fit the correct jets,

. adjust the minimum flame on the taps.

CHANGING THE JETS

JET

To gain access to the jets, remove the pan supports, and remove the burner cap and body,

Take a spanner and unscrew the jet.

According to the table below, fit the correct jet for the type of gas to be used,

Secure the jet tightly,

Replace the burner body, cap and the pan support.

Each jet is designated by size.

 

 

 

 

 

 

 

HOB BURNERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

auxiliary

semi-rapid

rapid

ultra-

4 Rings

 

 

 

 

 

rapid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

mbar

Jet

kW

Jet

kW

Jet

kW

Jet

Jet

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

G 20

20

76

1,00

101

1,75

118

2,50

144

141

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

G 25

25

76

0,90

101

1,60

118

2,30

144

141

3,20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30

29

50

1,00

66

1,75

80

2,50

94

96

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31

37

50

1,00

66

1,75

80

2,50

94

96

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

Factory setting: G 20-20 mbar - G 25-25 mbar

 

 

 

 

 