Honeywell VU443, VU444, VU843, VU844 Catalog Page

Honeywell VU443, VU444, VU843, VU844 Catalog Page

Fan Coil Actuators

VU443, VU444; VU843; VU844 Fan Coil Actuators

The VU844 Fan Coil Valve Actuators are used in conjunction with the VU52, VU53 and VU54 valves for controlling the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors. These valves are humidity resistant and are suitable for use in condensing, non-corrosive environments.

• Compact construction for easy installation

• Fits under the cover of most baseboard convectors with actuator fitted to valve body

• One-button, quick release

• Secure 3-point, metal latch to valve body

• Spring return operation

• Stainless steel case and aluminum cover

• Rust-proof nickel-plated motors available

• Line or low voltage, rust-resistant motors

• Manual opener for installation and valve operation on power failure

• Valve returns to automatic position when power is restored

• Actuator may be reinstalled or serviced without draining the system or disassembling the valve

• Slotted conduit hole for faster wiring

Dimensions in inches (millimeters)

7/8 DIA.

2-3/8

(22)

(60)

 

1

2

 

 

3-3/4

1-1/2

(133)

 

(38)

 

15/32

 

(12)

 

VU53 VALVE WITH VU448 ACTUATOR

1-3/4

1-3/4

 

 

(44)

(44)

 

 

 

 

1-3/4

1-3/4

 

 

(44)

(44)

3/8

 

 

 

(10)

 

 

 

 

 

3/8

 

 

 

(10)

 

B

A

 

 

 

7/8 (22)

 

 

 

2-WAY

B

 

7

 

3-WAY

 

AB

 

 

A

A

 

 

2-1/8 (54)

 

VU5 ACTUATOR

 

 

 

(INVERTED

 

 

 

FLARE)

 

 

 

VU53 AND VU54 VALVE WITH ACTUATOR

1HEIGHT NEEDED TO REMOVE ACTUATOR OR COVER

2OPENING FOR 1/2 IN. CONDUIT ON OPPOSITE SITE OF MANUAL LEVER FOR ALL MODELS.

VALVE BODY SIZE

A

B

 

1/2 IN. SWEAT

1-5/6 (33)

1-5/6 (33)

 

3/4 IN. SWEAT

1-3/8 (35)

1-11/16 (43)

 

1 IN. SWEAT

1-11/16 (43)

1-11/16 (43)

 

1/2 IN. NPT

1-3/8 (35)

1-5/16 (33)

 

3/4 IN. NPT

1-11/16 (43)

1-7/16 (37)

 

1 IN. NPT

1-11/16 (43)

1-7/16 (37)

M18261A

 

 

 

Actuator Type: Valve

Fail Safe Mode: Spring Return

Dimensions, Approximate: 2 3/8 in. high, 3 1/2 in. wide, 2 3/8 in. wide (62 mm high, 88 mm wide, 60 mm deep)

Electrical Connections: Leads Frequency: 60 Hz

Manual operation: Lever Stroke: 22 deg.

Power Consumption (driving): 6 Watts

Materials: Stainless Case, Aluminum Cover

Maximum Differential Pressure Ratings (Close-off): Depends on Cv rating of valve

Medium Temperature: 200 F (94 C)

Ambient Temperature Range: 34 F to 125 F ambient at 200 F Fluid (1 C to 52 C ambient at 93 C Fluid)

Approvals

Canadian Standards Association: Certified C/US File No. LR1322

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

Timing

 

 

 

Connection

 

 

 

Spring

 

 

 

 

(seconds)

 

 

 

Length

 

 

 

 

 

 

 

Type of

 

 

Type of

Number

 

Return

 

 

 

 

Maximum

Internal

 

 

 

 

Internal

of Internal

 

Timing

 

 

Product

Control

Driving @

Auxiliary

Switch

Supply

 

 

Auxiliary

Auxiliary

Stroke

(Nominal

 

Used

Number

Signal

60 Hz

Switch

Ratings

Voltage

(inch)

(m)

Switch

Switch

(inch)

(sec))

Comments

With

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU443A1008/U

Two

15 sec

120V

6 in.

0.15 m

0

22 deg.

4 sec.

For controlling the flow of

2-way NC

 

position;

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

VU valve

 

SPST

 

 

 

 

 

 

 

 

 

 

commercial HVAC

body

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

(VU53)

VU443A1024/U

Two

15 sec

208V

18 in.

0.5 m

0

22 deg.

4 sec.

units, terminal reheat coils

 

 

position;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

 

 

SPST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580

customer.honeywell.com

70-6910

 

 

 

 

 

 

 

 

 

 

Fan Coil Actuators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

Timing

 

 

 

Connection

 

 

 

Spring

 

 

 

 

 

(seconds)

 

 

 

Length

 

 

 

 

 

 

 

 

 

Type of

 

 

 

Type of

Number

 

Return

 

 

 

 

 

Maximum

Internal

 

 

 

 

Internal

of Internal

 

Timing

 

 

 

Product

Control

Driving @

Auxiliary

Switch

Supply

 

 

Auxiliary

Auxiliary

Stroke

(Nominal

 

Used

Number

Signal

60 Hz

Switch

Ratings

Voltage

(inch)

(m)

Switch

Switch

(inch)

(sec))

Comments

With

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU443A1057/U

Two

15 sec

277V

18 in.

0.5 m

0

22 deg.

4 sec.

For controlling the flow of

2-way NC

 

position;

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

VU valve

 

SPST

 

 

 

 

 

 

 

 

 

 

commercial HVAC

body

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

(VU53)

VU443A1115/U

Two

15 sec

230V

6 in.

0.15 m

0

22 deg.

4 sec.

units, terminal reheat coils

 

 

 

position;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

andconvectors

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU443A1180/U

Two

15 sec

120V

6 in.

0.15 m

0

22 deg.

4 sec.

Nickel plated motor for

 

 

 

position;

 

 

 

 

 

 

 

 

 

 

added humidity resistance;

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

For controlling the flow of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commercial HVAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU443E1009/U

Two

15 sec

SPST,

1 A Pilot

120V

18 in.

0.5 m

SPST,

1

22 deg.

4 sec.

For controlling the flow of

 

 

 

position;

 

N.O.

Duty

 

 

 

N.O.

 

 

 

hot or chilled water in

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

commercial HVAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors; Aux

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Rating - Inductive:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2 A from 5 to 110 Vac,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0 A from 110 to 277 Vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU444A1007/U

Two

15 sec

120V

6 in.

0.15 m

0

45 deg.

6 sec.

For controlling the flow of

2-way NO

 

position;

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

(VU52) or

 

SPST

 

 

 

 

 

 

 

 

 

 

commercial HVAC

3-way VU

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

valve

VU444A1098/U

Two

15 sec

227V

18 in.

0.5 m

0

45 deg.

6 sec.

units, terminal reheat coils

body

 

position;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

(VU54)

 

SPST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU444A1106/U

Two

15 sec

230V

6 in.

0.15 m

0

45 deg.

6 sec.

 

 

 

 

position;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU444A1155/U

Two

15 sec

120V

6 in.

0.15 m

0

45 deg.

6 sec.

Nickel plated motor for

 

 

 

position;

 

 

 

 

 

 

 

 

 

 

added humidity resistance;

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

For controlling the flow of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commercial HVAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU843A1004/U

Two

15 sec

24V

6 in.

0.15 m

0

22 deg.

4 sec.

For controlling the flow of

2-way NC

 

position;

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

VU valve

 

SPST

 

 

 

 

 

 

 

 

 

 

commercial HVAC

body

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

(VU53)

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU843A1087/U

Two

15 sec

24V

6 in.

0.15 m

0

22 deg.

4 sec.

Nickel plated motor for

 

 

 

position;

 

 

 

 

 

 

 

 

 

 

added humidity resistance;

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

For controlling the flow of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commercial HVAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU844A1003/U

Two

15 sec

24V

6 in.

0.15 m

0

45 deg.

6 sec.

For controlling the flow of

2-way NO

 

position;

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

(VU52) or

 

SPST

 

 

 

 

 

 

 

 

 

 

commercial HVAC

3-way VU

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

valve

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

body

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

(VU54)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VU844A1060/U

Two

15 sec

24V

6 in.

0.15 m

0

45 deg.

6 sec.

Nickel plated motor for

 

 

 

position;

 

 

 

 

 

 

 

 

 

 

added humidity resistance;

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

For controlling the flow of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hot or chilled water in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commercial HVAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment such as fan coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units, terminal reheat coils

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and convectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>Commercial

<![if ! IE]>

<![endif]>Components

70-6910

 

 

 

581

 

 