1. Features
NIGHT VISION IR DOME CAMERA
2
2. Safety Precautions
NIGHT VISION IR DOME CAMERA
3. Handling of the Unit
3
NIGHT VISION IR DOME CAMERA
4
NIGHT VISION IR DOME CAMERA
5
NIGHT VISION IR DOME CAMERA
6
7
NIGHT VISION IR DOME CAMERA
1
10. Dimension Outline
NIGHT VISION IR DOME CAMERA
User Guide
VDC-350PIV-V
The camera adopts advanced Digital Signal Processor(DSP) technology,Enhances picture quality greatly to horizontal resolution of 540TVL. Provides clearer and more vivid image.
capture high-resolution picture even in complete darkness. Night view distance up to10~15m.
Integrated efficient powerful IR LED array can
Light control design. Auto light detection for IR LED switch control.
The camera is equipped with a Vari-focal lens, f=4~9mm.
Accept 12VDC power supply.
Latest DSP controls for BLC, white balance, and gain control.
The installation should be made by qualified service personnel or system installers and should confirm to all local codes.
1.Power supply
(1) use with a 12VDC regulated power supply (2) To prevent fire or electrical shock, UL listed class 2 wiring should be used for the 12VDC input terminal. (3) Be used to connect each lead to the appropriate terminal. Wrong connection may cause malfunction and/or damage to the video camera.
2.Operating and storage locations
(1).Do not attempt to point the camera at the sun or other extremely bright objects that cause smear to
appear no matter the camera is power on or not. It leads to damage of the CCD(Charge Coupled
Device). (2).When camera is installed next to equipment,
such as wireless communication device, it emits a strong electromagnetic field, some irregularity such
as noise on the monitor screen may happen. (3).Be sure to use a ceiling board having enough strength to support this camera. (4).Assemble the camera's main parts and lens quickly in a sanitary place. (5).Do not pull the cable, it may cause disconnection. (6).Do not touch the inside of camera even if something is wrong. (7).Before installation, make sure to disconnect the
power supply first, check the ground connection, and then install it.
(8).Operating temperature range:-10℃~+50,(14°F~122°F); Storage temperature range:-20~+60,(-4°F~140°F).
(9). Be sure to use proper screws which cameras can be beared on the material firmly.
(1) Never attempt to disassemble or modify the camera.
(2) If an abnormality should occur, immediately turn off the power and consult your dealer.
6. Installation
4. Adjusting the Camera Direction
Camera body moves in three ways: pan, tilt and rotate. Adjust the direction so that the lens is pointing at the target.
5. Use the lever to adjust the view angle and focus.
8. Specifications
All data and specifications subject to change without notice.
9. Type Number Overview
Model(12VDC)
Signal system
PAL
VDC-350PIV-V
NTSC
VDC-350NIV-V
Manual pan /tilt mechanism,3-Axis Rotation.
Anda polygon dome shield, which can bear up to 120 pounds impact and won't be destroyed. It has excellent sealing performance and can also be installed by outdoor .
Polygon material made dome shield possesses
high light permeate rate, strong shock resistance capability. The whole Aluminum base can stand lasting shock and high temperature.
4. Parts Description
Front View
Body cover
Dome cover (transparent)
Camera body
Camera base
IR-LED
BOTTOM View
Mounting Holes
Wire hole
5. Cover Removal and Attachment
To remove the body cover and camera body, disassemble it with the L WRENCH provided in your ACCESSORY set. (Rotating clockwise will close it and rotating anti-clockwise will release it.)
Acecessories
3. L WRENCH
1. PLASTIC ANCHOR
2. ASSY SCREW TAPPING
1.PLASTIC ANCHOR: insert into the SCREW hole of the installation location(to strengthen the installation).
2.ASSY SCREW TAPPINGuse for installation on the ceiling or wall.
3. L WRENCHfor body cover and camera base assembly.
1.Drill a hole in the place where the camera is installed. Completely insert the PLASTIC ANCHOR provided. then lead the power and video cables pass through the hole.
2.Disassemble the body cover and camera base from dome camera .
3.Fasten the dome camera base on the wall or the ceiling.
Ceiling
Wall
Pan360°
Tilt 90°
Rotate 180°
View angle adjustment lever
Focus adjustment lever
6 urn the dome cover to adjust until the lens point at T the window, screw tightly and complete the installation.
.
Close
7. Connecting Low Voltage Power & Video Signal The wiring harness have a BNC connector to accept video signal ,the other connectors to accept the low voltage power. For mounting directly to a wall or ceiling, run power and video lines to the target location.
12VDC
VIDEO
NIGHT VISION IR DOME CAMERA
7. Self-Check Points Before Consulting After-Sales Services
Screen not turned on
*Make sure whether power is connected correctly. *Check if the cable is connected correctly.
Screen not clear or is spread
*If dust is seen through the monitor screen after fixing lens, dissemble the lens and clear off the dust on the surface of CCD withblower or soft cloth.
CONDITIONS
CHECKING POINTS
146mm
VDC-350NIV-V
Model VDC-350PIV-V VDC-350NIV- V
Image Sensor
Signal System PA L NTSC
Effective Pixels 752(H)x582(V) 7 68(H)x494(V)
Resolution
Minimum Illumina tion
Shutter Speed 1/ 50-1/100,000SEC 1/60-1/100,000S EC
S/N Ratio
White Balance
AGC/BLC
Gamma Correct ion
Sync Model
Lens
IR LED
IR Beam Distanc e
More Than 50dB
1/3'' SUPER H AD II CCD
0.1Lux/F1.2(IR LE D OFF), 0Lux (IR LED On)
540TV Lines(Colo r), 600TV Lines(B/W)
Automatic
Automatic
0.45
INT
Varifocal lens, f=4 -9mm
Wave Length 85 0nm, x 21pcs IR LED
10~15m
6
IR LED Drive
Video output
Power Input
Power Consumption
Operating Temperatu re
Body
Weight
On: 1~3Lux; Off: 5 ~6Lux
1.0Vp-p, 75Omh, Sync Negative Polarity
1000g
DC12V Regulated
150mA(IR LED OFF)+150mA(IR LED ON)
-10 +50, RH 90% MAX (non-condensing)
Aluminum