Honeywell V4500 User Manual

Vicks® Filter Free Humidifier
Use and Care Manual
IMPORTANT!
READ AND SAVE THESE INSTRUCTIONS
Models V4500, V4500-CAN
If you have any questions about the operation of your Vicks® Filter Free Humidifier, call our toll-free Consumer Relations line at 1-800-477-0457 or e-mail us at Consumerrelations@kaz.com.
k
Manufacturing Quality Healthcare Products for Over 75 Years
Important Safety Instructions
READ ALL INSTRUCTIONS BEFORE
USING HUMIDIFIER, ESPECIALLY THESE
BASIC SAFETY PRECAUTIONS:
1. Always place Humidifier on a firm, flat, level surface, at least FIVE inches away from
walls and heat sources such as stoves, radiators or heaters. Humidifier may not work properly on a non-level surface.
2. When moving, or lifting the Humidifier make sure you have a secure grip under the
Base of unit. When removing the Tank, use one hand on the Tank Handle and the other on the bottom of the Tank on the Fill Cap. This will help prevent leakage of water or breakage of the unit itself.
3. Place Humidifier in an area that is out of the reach of children.
4. Before using the Humidifier, extend the cord and inspect for any signs of damage. Do
not use the product if cord has been damaged.
5. This product has a polarized plug (one blade is wider than the other) as a safety feature.
This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
6. Humidifier should always be unplugged and emptied when not in operation or while
being cleaned.
7. Never tilt or move the Humidifier while it is in operation. Shut off and unplug
before moving.
8. Humidifier requires regular cleaning. Refer to and follow cleaning instructions
in this manual.
SAVE THESE INSTRUCTIONS
Vicks® Filter Free Humidifier (Models V4500, V4500-CAN)
Tank Handle
Motor Housing
Power Knob
Humidistat
Pick-Up Tube
Protective Cover
Base
Water Tank
Cap Gasket
(Black O-Ring)
Fill Cap
Using Your Vicks® Filter Free Humidifier
Your Vicks® Humidifier comes fully assembled and ready to use.
First Time Use
Read all instructions before using this appliance. If you have breathing difficulties, consult your doctor before using any humidifier.
Filling the Humidifier
1. Unpack Humidifier and remove all packaging materials.
2. Place Humidifier at least FIVE inches away from walls and heat sources, on a FIRM,
FLAT, LEVEL surface. Place on a water-resistant, non-conducting surface for protection from inadvertent spillage. Do not place any object over the Humidifier; it could block air openings.
3. Completely unravel power cord. Inspect power cord for signs of damage before use. If
cord is damaged, DO NOT use product, please call 1-800-477-0457.
4. Keep cord away from heated surfaces and out of the way, where it cannot be stepped on
or tripped over.
5. Remove Tank using Tank Handle. Turn Tank over and carefully remove Fill Cap by
turning Fill Cap counterclockwise. Fill the Tank with cool tap water. WARNING: Never use hot water — may cause damage to internal components. Do not add any type of medication or additive to the water.
6. Make sure the circular rubber Cap Gasket (O-Ring) is in place before replacing Fill Cap
on Tank (this prevents water leakage). To tighten, turn Fill Cap clockwise.
7. When carrying Tank always use two hands (one on Handle, one on the Fill Cap). Insert
Tank back into Base.
Distilled Water Recommended where Hard Water is present
In certain areas, tap water is very hard, containing a higher than normal concentration of various minerals. These minerals can be emitted into the air, possibly causing adverse reactions in people with breathing difficulties. In such cases, use only distilled or demineralized water and clean the humidifier every day.
If you have hard water, you may notice white dust forming on furniture near your humidifier. This can easily be wiped off with a damp cloth. To avoid white dust, use distilled or demineralized water.
Operating Instructions
1. Fill the Water Tank and place Tank on Base.
2. Make sure that switch is in OFF (O) position, place the unit on a flat, stable surface and
plug cord into a 120 VAC wall outlet.
CAUTION: DO NOT PLUG IN THE CORD WITH WET HANDS; ELECTRIC
SHOCK COULD RESULT.
3. Turn switch to desired speed. Green power light will come on. Fan will start turning and
cool mist will be visible within minutes.
4. Use the humidistat switch to select the humidity level you desire. To increase humidity
turn knob clockwise. When desired humidity level is reached, the humidifier will shut off and the green “desired humidity” light will come on. The humidistat will automatically turn the humidifier back on and off again to maintain the humidity level, with the desired humidity light indicating accordingly.
Scent Pad Heater Instructions
Your Vicks® Filter Free humidifier includes a scent pad heater so that you can enjoy Vicks® Soothing Menthol vapors to increase your comfort.
a. Open the lid of the Scent Pad heater tray.
b. Place one scent pad in the tray, being careful not to touch scent pad with your
hands. If your hands do come in contact with the pad, please wash them thoroughly as the menthol vapors can be an irritant.
c. Close lid and turn the unit on.
WARNING: As long as your humidifier is on, the scent pad heater will also be activated. This area can be warm to the touch.
NOTE: One complementary scent pad is included with your unit, replace with Vicks
VapoPads™, models VSP-19 and VSP-19-CAN, available at most retailers or through Kaz Consumer Relations or www.kaz.com.
®
Care and Cleaning
CAUTION: ALWAYS TURN OFF THE POWER SWITCH AND DISCONNECT THE POWER
CORD FROM THE ELECTRICAL OUTLET BEFORE CLEANING. Humidifiers provide comfort by adding moisture to dry indoor air. For maximized benefit
from your Vicks® Humidifier, follow instructions carefully. Please note that this is an electric appliance and requires careful attention when in use.
Tap water may contain pollutants and minerals (scale) that can deposit on the inner surfaces of the Humidifier. Such scale can accelerate the growth of microorganisms and can impair the performance.
Daily Maintenance
1. Turn switch to off (O) position and unplug the cord from wall outlet. Allow 3 minutes for
remaining water to drain from housing.
2. Remove Tank & Motor Housing and empty Base. Be careful to place Motor Housing
upside down to prevent damage to Pick-Up Tube.
3. Rinse Base and Tank, wipe clean, and dry with a clean cloth or paper towel.
Weekly Maintenance—Removing Scale
1. Turn switch to the OFF (O) position and unplug the cord from wall outlet. Allow 3 minutes
for motor housing to drain remaining water.
2. Remove Tank & Motor Housing and place on a flat surface. Be careful to place Motor
Housing upside down to prevent damage to Pick-Up Tube.
3. Empty any remaining water from the Base and Tank.
4. Remove the Protective Cover from the Motor Housing by loosening the 3 screws. The screws
are designed to stay with the cover to prevent loss. (Fig 1)
5. Carefully loosen and remove the Pick-Up Tube from the housing by holding the disk and
rotating the pickup tube in the direction of the “Off” arrow. (Fig 2)
6. Fill Base with undiluted white vinegar. Place Pick-Up Tube into Base with the vinegar. Let
solution stand for 5 minutes.
7. Dampen soft, clean cloth or sponge with undiluted white vinegar and wipe out Base,
Protective Cover and clean Pick-Up Tube to remove scale. DO NOT use soap, detergents or abrasive cleaners.
8. Rinse thoroughly in clean warm water to remove scale and vinegar before disinfecting
the Base.
Fig.3Fig. 1 Fig. 2
Disinfecting Base
1. Fill Base with water and add 1/4 teaspoon of bleach. Place Pick-Up Tube into Base and
let solution remain for 20 minutes, stirring every few minutes to ensure that all surfaces are coated.
2. Remove Pick-Up Tube and empty Base after 20 minutes. Wipe Protective Cover clean
with bleach mixture. Rinse with water until bleach smell is gone. Dry with clean cloth or paper towel.
3. Wipe all exterior surfaces of the Motor Housing with a soft, dry cloth.
DO NOT USE WATER TO CLEAN THE MOTOR HOUSING. AN ELECTRIC
SHOCK MAY RESULT OR THE HUMIDIFIER MAY BE DAMAGED. DO NOT IMMERSE OR SPRAY ANY PART OF THE HUMIDIFIER WITH WATER.
4. Reattach Pick-Up Tube to the top lid. Hold the disk and insert prongs in to the holes on
the disk. (Fig 3) Rotate the Pick-Up Tube in the direction of the “on Arrow”.
5. Re-attach the protective cover and tighten screws.
6. Reassemble the humidifier.
End of Season Maintenance or When Humidifier Will Not Be In Use For At Least One Week
1. Clean and dry the Humidifier thoroughly per the Weekly Maintenance instructions above.
2. Let Humidifier dry completely before storing. Do not store with water inside the Base.
3. Remove Fill Cap. Do not store Humidifier with Fill Cap on.
4. Store in a cool dry location.
Replacement Protec Cartridges & Scent Pads
PC-1, PC-1C Protec Cleaning Cartridges and VSP-19, VSP-19-CAN Vicks® VapoPads™ are generally available when you purchase your humidifier.
For US Customers:
If you are unable to locate these items at your retailer, they may be ordered directly from Kaz.
PC-1/PC-2 Protec™ Cleaning Cartridges cost $9.99 for 2 cartridges or $5.99 for 1
cartridge plus $4.95 for handling and postage
VSP-19 Vicks® VapoPads™ cost $5.99 for a package of 6 plus $4.95 for handling
and postage.
NOTE: Prices are subject to change without notice.
To Order:
By Phone: Call toll-free by dialing 1-800-477-0457. Please have your credit card handy for
payment. We accept Visa and Master Card. Minimum credit card order is $10.00.
By Fax: Fax your order to Kaz Consumer Relations Orders at 1-508-481-0509. Please
clearly print your name, mailing address and products ordered. Be sure to specify Visa or Master Card, card number and expiration date, and sign your order. Minimum credit card order is $10.00.
By Mail: Mail your order to Kaz Consumer Relations Orders, 250 Turnpike Road,
Southborough, MA 01772. Please clearly print your name, mailing address, and products ordered. Enclose check or money order (no cash, please).
Via The Internet: E-mail us at consumerrelations@kaz.com. Be sure to include your name,
mailing address and product ordered. Please specify Visa or Master Card, card number and expiration date. Minimum credit card order is $10.00.
For Canadian Customers:
Please visit your local retailer to purchase PC-1C Protec Cleaning cartridges and VSP-19-CAN Vicks® VapoPads™.
Troubleshooting
If the unit does not operate:
Check that polarized plug is fully inserted into wall outlet.
• Check airflow. Are there any obstructions preventing airflow?
The motor contains a temperature-limiting fuse. If the motor overheats, the fuse will trip
and shut off the motor. Unplug the unit and contact our Consumer Relations Department. Do not attempt to repair the motor yourself. Doing so will void your warranty.
If you do not obtain enough humidity:
It usually takes several uses before the unit reaches maximum output. Continue running
unit to make sure it is operating at top performance.
Check the water level in the tank and in the water tray. Refilling may be required.
The unit may need to be cleaned of scale build-up.
If you are obtaining too much humidity:
If room air is excessively humid (greater than 65% relative humidity), do not use the
humidifier. Excessive humidity is indicated by condensation on cold surfaces or wall in the room. For proper humidity readings, use a Vicks HealthCheck Monitor available from Kaz online or select retailers. Other hygrometer models are available in most hardware and department stores.
Lower your humidity control setting so that your humidifier will shut off when the desired
humidity level is reached.
If water leakage occurs:
Make sure unit is unplugged from wall outlet.
Remove Tank from Base and check Fill Cap. Make sure the Cap Gasket (O-Ring) is
properly positioned in the cap and the Spring Valve operates freely. If leakage still occurs contact our Consumer Relations Department.
If Fill Cap is too tight:
Lightly lubricate the Cap Gasket (O-Ring) with petroleum jelly.
Loading...
+ 21 hidden pages