V4043
FEATURES
Motor open
Spring return action
the system
Powerhead replaceable without
draining down
Potential free end switch for electrical
control of pump and/or boiler
Quiet operation, minimal power
consumption
OPTIONS
Normally open & normally closed
versions available
22mm/28mm or1/2",3/4", 1" BSP
connections
Replacement motor
Replacement powerhead
Replacement ball and
‘O’ ring kit
The V4043 series of two port Motorised Valves has a wide range of flow control applications in domestic and light commercial central heating systems.
The V4043H normally closed models have end switches for electrical control of pump and/or boiler. The V4043B normally open model is particularly applicable to control of solid fuel systems, since it will always fail-safe in the event of a power failure.
APPLICATION
HEATING CONTROLS
© Honeywell Control Products and Systems, Issue 10
4.19
MOTORISED ZONE VALVES V4043B/C/H
MOTOR
BROWN
BLUE
ORANGE
GREY
G/YELLOW
AUX.SWITCH
WHITE 28mm and 1 BSP ONLY
Installation
he V4043 Zone Valve must be
T positioned where it cannot block any vent or cold feed when closed. It may
e plumbed in at any angle but must
b not be mounted so that the powerhead is below the horizontal level of the pipework.
If fitted in a confined space, sufficient ventilation must be available to keep the valve within its ambient temperature range and access must be provided to remove the powerhead if necessary.
Ordering Specification
V4043B1257
Normally open, 22mm compression. No end switch. No manual lever.
6.9 KV. Maximum close-off differential pressure 0.55 bar
V4043B1265
As above, but 28mm comp. 8.6 KV.
0.45 bar max. diff. pressure
V4043C1156
Normally closed, end switch. 3.0 KV. 1.38 bar max. diff
V4043H1056
Normally closed, 22mm compression. SPST end switch. 6.9 KV. 0.55 bar max differential pressure
1
/2" BSP female. No
Specification
Power Supply : 230VAC 50Hz
Switch Rating : 2.2 Amps
lectrical Connections : 1m flying lead, heat resistant cable
E
Switch Type : See specifications
Ambient Temperature Range : 5 to 50˚C
Flow Temperature : 5 to 88˚C
Static Pressure : 8.6 bar max
Flow Directions : As per arrow on valve body
Standards : CE, UL, CSA
Approvals : 89/336/EEC & 73/23/EEC
Note: Continuous operation of the valve motor at the fully open position is not recommended.
Dimensions (mm)
A 87
B 98
C 60
D1/2” 94
22mm 112
1” 92
28mm 127
Wiring
Flow Characteristics
V4043H1007
3
As above but
/4" BSP connections
V4043H1106
Normally closed, 28mm compression. SPDT end switch. 8.6 KV. 0.45 bar max differential pressure
V4043H1080
As above but 1" BSP connections
40001011-002
24VAC motor kit (low voltage applications)
40002737-003
240VAC replacement motor
40003916-001
Replacement powerhead
40003918-006
Plate & ball assembly kit – use with valves that do not have replaceable heads (Pre 1987)
272752A/U CARD
Replacement Ball & ‘O’ ring kit
© Honeywell Control Products and Systems, Issue 10, 4.19