Optimal-plus manual valves are installed on the supply of radiators and heat exchangers in warm water heating systems.
Control of the room temperature is done by manually opening
or closing the valve.
Features
• Convertible to thermostatic control, also when installed
and in operation
• Robust valve housing made of corrosion resistant red
bronze with good flow and sound properties
• Maintenance-free spindle sealing
• Valve housing with dimensions according to EN215,
Appendix A, Series D
• Non-rising handwheel
• Connection to all types of pipe DN10...DN20
Straight
Design
The manual radiatior valves consists of:
• Valve housing PN10, DN10, 15 or 20 with
• internal thread connection to DIN2999 (ISO7) for threaded,
copper or precision steel pipe on inlet (compression ring
fittings see ‘Accessories’)
• external thread connection to DIN/ISO228 with union-nut
and radiator tailpiece on outlet
• Valve insert
• Handwheel
Materials
• Valve housing made of nickel-plated red bronze
• Valve insert made of brass with EPDM O-rings
• Handwheel made of white plastic
• Threaded tailpiece and connection nut made of nickel-plated
brass
Specifications
MediumHeating water, water quality to
VDI2035
pH-value8...9.5
Operating temperature max. 90°C (194°F)
Operating pressurePN 10
k
Leakage rate≤ 0.01 % of k
Thermostat connection M30 x 1.5
-value
v
Honeywell y Subject to changeEN0H-2119GE25 R1106
V2652 - OPTIMAL-PLUS
Function
The orifice between valve seat and valve cartridge increases
when the valve is opened by turning the handwheel anti-clockwise. More heating water can flow into the radiator or heat
exchanger and the room temperature rises.
The orifice between valve seat and valve cartridge decreases
when the valve is closed by turning the handwheel clockwise
and the supply of heating water into the radiator or heat
exchanger is throttled. At the right limit stop the valve is closed
except for a possible leakage rate.
Dimensions and Ordering Information
Please Note:
• To avoid stone deposit and corrosion the composition of the
medium should conform with VDI-Guideline 2035
• Additives have to be suitable for EPDM sealings
• System has to be flushed thoroughly before initial operation
with all valves fully open
• Any complaints or costs resulting from non-compliance with
above rules will not be accepted by Honeywell
• Please contact us if you should have any special requirements or needs
Fig. 1. AngleFig. 2. Straight
T able 1. Dimensions and OS-Nos. (OS=Order Specification)
NOTE: All dimensions in mm unless stated otherwise.
EN0H-2119GE25 R11062Honeywell y Subject to change
Accessories
Compression ring and nut
3/8" x 10 mmVA620A1010
3/8" x 12 mmVA620A1012
1/2" x 10 mmVA620A1510
1/2" x 12 mmVA620A1512
1/2" x 14 mmVA620A1514
1/2" x 15 mmVA620A1515
1/2" x 16 mmVA620A1516
3/4" x 18 mmVA620A2018
3/4" x 22 mmVA620A2022
NOTE: Support inserts have to be used for copper or soft
steel pipe with 1.0 mm wall thickness
Compression ring and nut with support insert (2 pcs
each)
3/8" x 12 mmVA621A1012
1/2" x 12 mmVA621A1512
1/2" x 15 mmVA621A1515
1/2" x 16 mmVA621A1516
3/4" x 18 mmVA621A2018
Compression ring and nut with support insert for composite pipe (2 pcs each)
1/2" x 14 mmVA622B1514
1/2" x 16 mmVA622B1516
V2652 - OPTIMAL-PLUS
Extended radiator tailpiece, nickel-plated, to be shortened
as required
3/8" x 70 mm (for DN10)
thread approx. 50 mm
1/2" x 76 mm (for DN15)
thread approx. 65 mm
3/4" x 70 mm (for DN20)
thread approx. 60 mm
Soldering tailpiece
3/8" x 12 mm (for DN10)VA5230A010
1/2" x 15 mm (for DN15)VA5230A015
3/4" x 22 mm (for DN20)VA5230A020
Pressure cap – for closing of radiator outlet valves
for valves DN10 (3/8")VA2202A010
for valves DN15 (1/2")VA2202A015
for valves DN20 (3/4")VA2202A020
Sealing ring for pressure cap
for valves DN10 (3/8")VA5090A010
for valves DN15 (1/2")VA5090A015
for valves DN20 (3/4")VA5090A020