V2480 - Verafix Design
Thera Design Edition - Lockshield Valve
WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS
PRODUCT DATA
Angle
Straight
Double angle right |
Double angle left |
Design
The Verafix design tlockshield valve consists of:
•Valve housing PN10, DN15 with
•external thread connection on inlet
•external thread connection with union-nut and radiator tailpiece on outlet
•Pre-settable valve insert
•Protection cap
Application
The new Thera Design Edition is particularly styled for use with design radiators. With their high class appearance they perfectly fit to all kinds of ambients.
Verafix Design lockshield valves are used to connect radiators and other heat exchangers to heating circuits of hydronic heating systems. They are installed at the return port of the radiator and offer a shutoff function to separate the radiator from the heating circuit, for example for renovating.
Features
•Perfect finishing with high quality surface in chrome or white (RAL9016)
•Varius versions in angle, straight and double angle available to fit a visual appealing installation
•Including a chromed tail piece with integrated O-ring
•Pre-settable
•Connection to all types of pipework
Specifications
Medium |
Water or water-glycol mixture, |
|
quality to VDI 2035 |
pH-value |
8…9,5 |
Operating temperature |
2...130°C (36...266°F) |
Operating pressure |
PN10 |
Differential pressure |
max. 1 bar (14.5 psi) – |
|
max. 0.2 bar (2.9 psi) recommended |
|
for quiet operation |
kv(cv)-value |
1.18 (1.38) |
Materials
•Valve housing made of brass with chrome or white (RAL 9016) surface
•Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle
•Protection cap made of brass with chrome or white (RAL 9016) surface
•Union-nut and tailpiece made of chrome plated brass with EPDM O-ring
Honeywell y Subject to change |
EN0H-2109GE25 R0408 |
THERA DESIGN EDITION - LOCKSHIELD VALVE
Function
The Verafix Design connects the return of a radiator or heat exchanger to the heating loop and has the functions regulation and shutoff.
Regulation:
The flow can be regulated by pre-setting the valve to a certain value derived from the flow diagrams.
Please Note:
•To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035
•Additives have to be suitable for EPDM sealings
•System has to be flushed thoroughly before initial operation with all valves fully open
•Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell
•Please contact us if you should have any special requirements or needs
Application Examples
Fig. 1. Angle version |
Fig. 2. Straight version |
Fig. 3. Double angle version |
EN0H-2109GE25 R0408 |
2 |
Honeywell y Subject to change |