Honeywell V2480 PRODUCT DATA

Honeywell V2480 PRODUCT DATA

V2480 - Verafix Design

Thera Design Edition - Lockshield Valve

WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

PRODUCT DATA

Angle

Straight

Double angle right

Double angle left

Design

The Verafix design tlockshield valve consists of:

Valve housing PN10, DN15 with

external thread connection on inlet

external thread connection with union-nut and radiator tailpiece on outlet

Pre-settable valve insert

Protection cap

Application

The new Thera Design Edition is particularly styled for use with design radiators. With their high class appearance they perfectly fit to all kinds of ambients.

Verafix Design lockshield valves are used to connect radiators and other heat exchangers to heating circuits of hydronic heating systems. They are installed at the return port of the radiator and offer a shutoff function to separate the radiator from the heating circuit, for example for renovating.

Features

Perfect finishing with high quality surface in chrome or white (RAL9016)

Varius versions in angle, straight and double angle available to fit a visual appealing installation

Including a chromed tail piece with integrated O-ring

Pre-settable

Connection to all types of pipework

Specifications

Medium

Water or water-glycol mixture,

 

quality to VDI 2035

pH-value

8…9,5

Operating temperature

2...130°C (36...266°F)

Operating pressure

PN10

Differential pressure

max. 1 bar (14.5 psi) –

 

max. 0.2 bar (2.9 psi) recommended

 

for quiet operation

kv(cv)-value

1.18 (1.38)

Materials

Valve housing made of brass with chrome or white (RAL 9016) surface

Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle

Protection cap made of brass with chrome or white (RAL 9016) surface

Union-nut and tailpiece made of chrome plated brass with EPDM O-ring

Honeywell y Subject to change

EN0H-2109GE25 R0408

THERA DESIGN EDITION - LOCKSHIELD VALVE

Function

The Verafix Design connects the return of a radiator or heat exchanger to the heating loop and has the functions regulation and shutoff.

Regulation:

The flow can be regulated by pre-setting the valve to a certain value derived from the flow diagrams.

Please Note:

To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035

Additives have to be suitable for EPDM sealings

System has to be flushed thoroughly before initial operation with all valves fully open

Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell

Please contact us if you should have any special requirements or needs

Application Examples

Fig. 1. Angle version

Fig. 2. Straight version

Fig. 3. Double angle version

EN0H-2109GE25 R0408

2

Honeywell y Subject to change

Loading...